Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.144
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
2.
Transl Vis Sci Technol ; 13(5): 7, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727695

RESUMEN

Purpose: Multiple clinical visits are necessary to determine progression of keratoconus before offering corneal cross-linking. The purpose of this study was to develop a neural network that can potentially predict progression during the initial visit using tomography images and other clinical risk factors. Methods: The neural network's development depended on data from 570 keratoconus eyes. During the initial visit, numerical risk factors and posterior elevation maps from Scheimpflug imaging were collected. Increase of steepest keratometry of 1 diopter during follow-up was used as the progression criterion. The data were partitioned into training, validation, and test sets. The first two were used for training, and the latter for performance statistics. The impact of individual risk factors and images was assessed using ablation studies and class activation maps. Results: The most accurate prediction of progression during the initial visit was obtained by using a combination of MobileNet and a multilayer perceptron with an accuracy of 0.83. Using numerical risk factors alone resulted in an accuracy of 0.82. The use of only images had an accuracy of 0.77. The most influential risk factors in the ablation study were age and posterior elevation. The greatest activation in the class activation maps was seen at the highest posterior elevation where there was significant deviation from the best fit sphere. Conclusions: The neural network has exhibited good performance in predicting potential future progression during the initial visit. Translational Relevance: The developed neural network could be of clinical significance for keratoconus patients by identifying individuals at risk of progression.


Asunto(s)
Topografía de la Córnea , Aprendizaje Profundo , Progresión de la Enfermedad , Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Femenino , Masculino , Adulto , Topografía de la Córnea/métodos , Adulto Joven , Factores de Riesgo , Córnea/diagnóstico por imagen , Córnea/patología , Adolescente , Persona de Mediana Edad , Redes Neurales de la Computación
3.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717080

RESUMEN

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Asunto(s)
Astigmatismo , Sustancia Propia , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Agudeza Visual/fisiología , Estudios Retrospectivos , Adulto , Refracción Ocular/fisiología , Masculino , Femenino , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Sustancia Propia/cirugía , Láseres de Excímeros/uso terapéutico , Topografía de la Córnea , Estudios de Seguimiento , Resultado del Tratamiento , Cirugía Laser de Córnea/métodos
4.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717081

RESUMEN

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Cirugía Asistida por Computador , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Estudios Prospectivos , Refracción Ocular/fisiología , Adulto , Masculino , Femenino , Láseres de Excímeros/uso terapéutico , Método Doble Ciego , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad , Córnea/cirugía , Córnea/fisiopatología , Estudios de Seguimiento
5.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
6.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
7.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717086

RESUMEN

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Asunto(s)
Córnea , Elasticidad , Presión Intraocular , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Humanos , Córnea/fisiopatología , Córnea/cirugía , Adulto , Femenino , Masculino , Fenómenos Biomecánicos , Láseres de Excímeros/uso terapéutico , Queratomileusis por Láser In Situ/métodos , Adulto Joven , Elasticidad/fisiología , Miopía/cirugía , Miopía/fisiopatología , Presión Intraocular/fisiología , Queratectomía Fotorrefractiva/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
8.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693352

RESUMEN

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Asunto(s)
Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Adulto , Femenino , Masculino , Topografía de la Córnea/métodos , Adulto Joven , Aberrometría/métodos , Córnea/diagnóstico por imagen , Córnea/patología , Análisis de Fourier
9.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38739130

RESUMEN

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Asunto(s)
Córnea , Topografía de la Córnea , Glaucoma , Presión Intraocular , Tonometría Ocular , Humanos , Tonometría Ocular/métodos , Córnea/diagnóstico por imagen , Presión Intraocular/fisiología , Masculino , Femenino , Persona de Mediana Edad , Topografía de la Córnea/métodos , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Reproducibilidad de los Resultados , Anciano , Adulto
10.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741093

RESUMEN

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Aberración de Frente de Onda Corneal , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Miopía/cirugía , Miopía/fisiopatología , Astigmatismo/fisiopatología , Astigmatismo/etiología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Cirugía Laser de Córnea/métodos , Cirugía Laser de Córnea/efectos adversos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Adulto Joven , Refracción Ocular/fisiología , Sustancia Propia/cirugía , Estudios Retrospectivos , Láseres de Excímeros/uso terapéutico , Complicaciones Posoperatorias , Topografía de la Córnea , Adolescente
11.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557918

RESUMEN

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/tratamiento farmacológico , Queratocono/terapia , Queratocono/metabolismo , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Adulto Joven , Refracción Ocular/fisiología , Colágeno/metabolismo , Resultado del Tratamiento , Córnea/patología , Rayos Ultravioleta , Estudios de Seguimiento , Adolescente , Recuento de Células , Sustancia Propia/metabolismo , Endotelio Corneal/patología , Lentes de Contacto Hidrofílicos , Reticulación Corneal
12.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
13.
BMC Ophthalmol ; 24(1): 163, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609888

RESUMEN

BACKGROUND: The aim was to validate the correlation between corneal shape parameters and axial length growth (ALG) during orthokeratology using Image-Pro Plus (IPP) 6.0 software. METHODS: This retrospective study used medical records of myopic children aged 8-13 years (n = 104) undergoing orthokeratology. Their corneal topography and axial length were measured at baseline and subsequent follow-ups after lens wear. Corneal shape parameters, including the treatment zone (TZ) area, TZ diameter, TZ fractal dimension, TZ radius ratio, eccentric distance, pupil area, and pupillary peripheral steepened zone(PSZ) area, were measured using IPP software. The impact of corneal shape parameters at 3 months post-orthokeratology visit on 1.5-year ALG was evaluated using multivariate linear regression analysis. RESULTS: ALG exhibited significant associations with age, TZ area, TZ diameter, TZ fractal dimension, and eccentric distance on univariate linear regression analysis. Multivariate regression analysis identified age, TZ area, and eccentric distance as significantly correlated with ALG (all P < 0.01), with eccentric distance showing the strongest correlation (ß = -0.370). The regressive equation was y = 1.870 - 0.235a + 0.276b - 0.370c, where y represents ALG, a represents age, b represents TZ area, and c represents eccentric distance; R2 = 0.27). No significant relationships were observed between the TZ radius ratio, pupillary PSZ area, and ALG. CONCLUSIONS: IPP software proves effective in capturing precise corneal shape parameters after orthokeratology. Eccentric distance, rather than age or the TZ area, significantly influences ALG retardation.


Asunto(s)
Cristalino , Niño , Humanos , Estudios Retrospectivos , Topografía de la Córnea , Análisis Multivariante , Programas Informáticos
14.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656032

RESUMEN

We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.


Asunto(s)
Queratomileusis por Láser In Situ , Facoemulsificación , Colgajos Quirúrgicos , Agudeza Visual , Humanos , Facoemulsificación/efectos adversos , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/métodos , Masculino , Diplopía/etiología , Resultado del Tratamiento , Topografía de la Córnea , Catarata , Persona de Mediana Edad
15.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649848

RESUMEN

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Asunto(s)
Segmento Anterior del Ojo , Córnea , Topografía de la Córnea , Miopía , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Adulto , Miopía/diagnóstico , Miopía/fisiopatología , Topografía de la Córnea/métodos , Topografía de la Córnea/instrumentación , Reproducibilidad de los Resultados , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/patología , Adulto Joven , Córnea/diagnóstico por imagen , Córnea/patología , Persona de Mediana Edad , Biometría/métodos , Adolescente , Estudios Prospectivos
16.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600456

RESUMEN

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Miopía , Humanos , Refracción Ocular , Coma , Topografía de la Córnea , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Astigmatismo/cirugía , Sustancia Propia/cirugía
17.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648457

RESUMEN

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Asunto(s)
Córnea , Sustancia Propia , Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Implantación de Prótesis/métodos , Córnea/patología , Estudios de Seguimiento , Sustancia Propia/patología , Sustancia Propia/cirugía , Agudeza Visual/fisiología , Fenómenos Biomecánicos , Adulto Joven , Persona de Mediana Edad , Refracción Ocular/fisiología , Diseño de Prótesis , Adolescente
18.
BMJ Open Ophthalmol ; 9(1)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38653536

RESUMEN

OBJECTIVE: Our objective is to develop a novel keratoconus image classification system that leverages multiple pretrained models and a transformer architecture to achieve state-of-the-art performance in detecting keratoconus. METHODS AND ANALYSIS: Three pretrained models were used to extract features from the input images. These models have been trained on large datasets and have demonstrated strong performance in various computer vision tasks.The extracted features from the three pretrained models were fused using a feature fusion technique. This fusion aimed to combine the strengths of each model and capture a more comprehensive representation of the input images. The fused features were then used as input to a vision transformer, a powerful architecture that has shown excellent performance in image classification tasks. The vision transformer learnt to classify the input images as either indicative of keratoconus or not.The proposed method was applied to the Shahroud Cohort Eye collection and keratoconus detection dataset. The performance of the model was evaluated using standard evaluation metrics such as accuracy, precision, recall and F1 score. RESULTS: The research results demonstrated that the proposed model achieved higher accuracy compared with using each model individually. CONCLUSION: The findings of this study suggest that the proposed approach can significantly improve the accuracy of image classification models for keratoconus detection. This approach can serve as an effective decision support system alongside physicians, aiding in the diagnosis of keratoconus and potentially reducing the need for invasive procedures such as corneal transplantation in severe cases.


Asunto(s)
Queratocono , Queratocono/diagnóstico , Queratocono/clasificación , Humanos , Córnea/patología , Algoritmos , Topografía de la Córnea/métodos
19.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593257

RESUMEN

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Asunto(s)
Astigmatismo , Humanos , Adulto Joven , Adulto , Estudios Prospectivos , Córnea , Pupila , Biometría , Topografía de la Córnea , Refracción Ocular
20.
J Refract Surg ; 40(4): e260-e269, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593263

RESUMEN

PURPOSE: To compare the parameters of three different topographic devices (Pentacam HR, Oculus Optikgeräte GmbH; Sirius, Costruzione Strumenti Oftalmici; and Cassini, i-Optics) in grading the severity of keratoconus in cross-linked and non-cross-linked eyes. METHODS: This was a prospective comparative interventional study done in a tertiary eye care center, wherein 114 eyes of 68 patients with keratoconus were divided into two groups: 62 eyes that were observed and 52 eyes that were cross-linked. All eyes were evaluated on all three topographers at baseline, 3-month follow-up, and 6-month follow-up. RESULTS: The Sirius showed significantly lower values of mean flat keratometry in comparison to the Pentacam HR (limits of agreement [LoA]: 1.75 to 3.51%) and Cassini (LoA: 1.75 to 3.51%). The mean steep keratometry values were higher for the Cassini in comparison to the Pentacam HR (LoA: 4.39 to 7.02%) and Sirius (LoA: 3.51 to 6.14%). The mean steep keratometry values of the Sirius were significantly lower than those of the Pentacam HR and in both the cross-linked and observation groups (LoA: 3.51 to 6.14%). The mean keratometry values were significantly higher in the Cassini compared to the Pentacam HR (LoA: 3.51 to 8.77%) and significantly lower in the Sirius in comparison to the Pentacam HR (LoA: 3.51 to 6.14%). The mean difference in astigmatism was also statistically significant between the three tomographers in both groups, with the Cassini showing higher values (LoA: 3.51 to 5.26%) and the Sirius lower values than the Pentacam HR (LoA: 5.26 to 6.14%). CONCLUSIONS: The authors conclude the three devices cannot be used interchangeably. The Cassini showed better agreement and correlation with the Pentacam HR in the staging of keratoconus, whereas the Sirius tended to underdiagnose and under-stage the disease. [J Refract Surg. 2024;40(4):e260-e269.].


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Topografía de la Córnea , Estudios Prospectivos , Reproducibilidad de los Resultados , Córnea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...