Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Ann Lab Med ; 41(1): 51-59, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32829579

RESUMEN

BACKGROUND: A small shift in high-sensitivity cardiac troponin T (hs-cTnT) assays can lead to different result interpretation and consequent patient management. We explored whether a small bias could be detected using conventional internal quality control (QC) procedures, evaluated the performance of moving average (MA)-based QC procedures, and proposed a new QC procedure based on the moving rate (MR) of positive patient results of hs-cTnT assays. METHODS: The ability of conventional QC to detect a 5 ng/L bias was examined using the13s/ 22s/R4s multi-rule procedure as deviation rules.We developed MA and MR procedures for the hs-cTnT assay using eight months of patient data. The performance of different MA or MR procedures was investigated by calculating the median number of patient samples affected until a bias introduced into the dataset was detected (MNPed). After comparing the MNPed across different procedures, we selected an optimal MA or MR procedure for validation. Validation graphs were plotted using the minimum, median, and maximum number of results affected until bias detection. RESULTS: Our conventional QC procedures could not detect a positive bias of 5 ng/L. When a positive bias was introduced, MNPed was much higher using MA than using MR, with cut-off values of 5 ng/L and 14 ng/L, respectively. MR validation charts for optimal procedures provided insight into the MR performance. CONCLUSIONS: The MR procedure could detect different errors with few false alarms. In the hs-cTnT assay, the MR procedure with a smaller cut-off value outperformed MA and conventional QC procedures for small bias detection.


Asunto(s)
Troponina T/sangre , Algoritmos , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoensayo/normas , Mediciones Luminiscentes , Infarto del Miocardio sin Elevación del ST/diagnóstico , Control de Calidad , Estudios Retrospectivos , Troponina T/normas
2.
Clin Chem ; 67(1): 256-264, 2021 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-33279972

RESUMEN

BACKGROUND: Many studies have assessed the biological variation (BV) of cardiac-specific troponins (cTn), reporting widely varying within-subject BV (CVI) estimates. The aim of this study was to provide meta-analysis-derived BV estimates for troponin I (cTnI) and troponin T (cTnT) for different sampling intervals and states of health. METHODS: Relevant studies were identified by a systematic literature search. Studies were classified according to their methodological quality by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC-compliant studies were performed after stratification by cTn isoform, exclusion of results below the limit of detection, states of health, and sampling interval to deliver reference change values (RCV), index of individuality (II) and analytical performance specifications (APS) for these settings. RESULTS: Sixteen and 15 studies were identified for cTnI and cTnT, respectively, out of which 6 received a BIVAC grade A. Five studies had applied contemporary cTnI assays, but none contemporary cTnT. High-sensitivity (hs-) cTnI and cTnT delivered similar estimates in all settings. Long-term CVI estimates (15.1; 11.3%) derived from healthy individuals were higher than short-term (4.3%; 5.3%) for hs-cTnI and hs-cTnT, respectively, although confidence intervals overlapped. Estimates derived from diseased subjects were similar to estimates in healthy individuals for all settings. CONCLUSIONS: This study provides robust estimates for hs-cTnI and hs-cTnT applicable for different clinical settings and states of health, allowing for the use of RCV both to aid in the diagnosis of myocardial injury and for prognosis. BV-based APS appear too strict for some currently available technologies.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Enfermedades Renales/diagnóstico , Troponina I/análisis , Troponina T/análisis , Variación Biológica Individual , Biomarcadores/análisis , Humanos , Pronóstico , Valores de Referencia , Troponina I/normas , Troponina T/normas
3.
Clin Chem ; 66(9): 1167-1180, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32871000

RESUMEN

BACKGROUND: Concerns exist regarding how the 99th percentile upper reference limit (URL) of cardiac troponin (cTn) is determined and whether it should be derived from normal healthy individuals. CONTENT: The 99th percentile URL of cTn is an important criterion to standardize the diagnosis of myocardial infarction (MI) for clinical, research, and regulatory purposes. Statistical heterogeneity in its calculation exists but recommendations have been proposed. Some negativity has resulted from the fact that with some high-sensitivity (hs) cTn assays, a greater number of increases above the 99th percentile are observed when transitioning from a contemporary assay. Increases reflect acute or chronic myocardial injury and provide valuable diagnostic and prognostic information. The etiology of increases can sometimes be difficult to determine, making a specific treatment approach challenging. For those reasons, some advocate higher cutoff concentrations. This approach can contribute to missed diagnoses. Contrary to claims, neither clinical or laboratory guidelines have shifted away from the 99th percentile. To support the diagnosis of acute MI, the 99th percentile URL remains the best-established approach given the absence of cTn assay standardization. Importantly, risk stratification algorithms using hs-cTn assays predict the possibility of MI diagnoses established using the 99th percentile. SUMMARY: The 99th percentile of cTn remains the best-established criterion for the diagnosis of acute MI. While not perfect, it is analytically and clinically evidence-based. Until there are robust data to suggest some other approach, staying with the 99th percentile, a threshold that has served the field well for the past 20 years, appears prudent.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Troponina T/sangre , Enfermedad Aguda , Biomarcadores/sangre , Humanos , Infarto del Miocardio/sangre , Valores de Referencia , Troponina I/normas , Troponina T/normas
4.
Clin Chem ; 66(3): 434-444, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32109298

RESUMEN

BACKGROUND: How to select healthy reference subjects in deriving 99th percentiles for cardiac troponin assays still needs to be clarified. To assist with global implementation of high sensitivity (hs)-cardiac troponin (cTn) I and hs-cTnT assays in clinical practice, we determined overall and sex-specific 99th percentiles in 9 hs-cTnI and 3 hs-cTnT assays using a universal sample bank (USB). METHODS: The Universal Sample Bank (USB) comprised healthy subjects, 426 men and 417 women, screened using a health questionnaire. Hemoglobin A1c (>URL 6.5%), NT-proBNP (>URL 125 ng/L) and eGFR (<60 mL/min), were used as surrogate biomarker exclusion criteria along with statin use. 99th percentiles were determined by nonparametric, Harrell--Davis bootstrap, and robust methods. RESULTS: Subjects were ages 19 to 91 years, Caucasian 58%, African American 27%, Pacific Islander/Asian 11%, other 4%, Hispanic 8%, and non-Hispanic 92%. The overall and sex-specific 99th percentiles for all assays, before and after exclusions (n = 694), were influenced by the statistical method used, with substantial differences noted between and within both hs-cTnI and hs-cTnT assays. Men had higher 99th percentiles (ng/L) than women. The Roche cTnT and Beckman and Abbott cTnI assays (after exclusions) did not measure cTn values at ≥ the limit of detection in ≥50% women. CONCLUSIONS: Our findings have important clinical implications in that sex-specific 99th percentiles varied according to the statistical method and hs-cTn assay used, not all assays provided a high enough percentage of measurable concentrations in women to qualify as a hs-assay, and the surrogate exclusion criteria used to define normality tended to lower the 99th percentiles.


Asunto(s)
Bioensayo/métodos , Troponina I/sangre , Troponina T/sangre , Adulto , Anciano , Anciano de 80 o más Años , Bioensayo/normas , Bancos de Muestras Biológicas , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Juego de Reactivos para Diagnóstico , Valores de Referencia , Factores Sexuales , Troponina I/normas , Troponina T/normas , Adulto Joven
5.
Clin Biochem ; 78: 18-24, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31786204

RESUMEN

OBJECTIVE: To determine gender-specific reference limits of high-sensitivity (hs) cardiac troponins (cTn) and validity of hs assay designation for both genders. METHODS: After screening with a questionnaire, 827 presumably healthy individuals were further selected based on clinical criteria (n = 740), clinical criteria plus cardiac imaging including stress magnetic resonance imaging or stress echocardiography (n = 726), and extended cardio-pulmonary parameters (n = 626). Blood samples were measured with hs-cTnT (Roche Diagnostics) on a cobas e602 analyzer as well as hs-cTnI (Abbott Diagnostics) on an ARCHITECTi2000SR. The impact of health definition, statistical methods, instrument selection and limit of detection (LoD) on overall and gender-specific 99th percentiles was assessed. RESULTS: Median age was 56 years (50.9% female) for the total study cohort. 99th percentiles for females and males ranged between 13.1 and 13.3 ng/L and 16.8-19.9 ng/L for hs-cTnT as well as 10.3-12.5 ng/L and 27.4-29.7 ng/L for hs-cTnI depending on health definition. Utilization of stricter health definition criteria reduced the difference of the gender-specific 99th percentiles between males and females for hs-cTnT to 3.7 ng/L (males 16.8 ng/L, females 13.1 ng/L), whereas the difference rather increased for hs-cTnI to 19.4 ng/L (males 29.7 ng/L, females 10.3 ng/L). Values > LoD could be measured in the majority of males and females using hs-TnT (81.4-83.3% and 96.5-96.9%, respectively). In contrast, values > LoD could not be observed in the majority of females using hs-cTnI (38.4-41.1%). CONCLUSIONS: In a well-phenotyped healthy cohort, reference values for hs-cTnT were slightly higher, whereas hs-cTnI cut-offs were considerably lower than previously observed. Gender differences were more pronounced in hs-cTnI than in hs-cTnT and were further reduced for hs-cTnT by application of stricter health definition criteria. Contrary to hs-cTnI, hs-cTnT fulfilled criteria for hs designation for both genders.


Asunto(s)
Análisis Químico de la Sangre/normas , Troponina I/sangre , Troponina T/sangre , Factores de Edad , Anciano , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Fenotipo , Valores de Referencia , Sensibilidad y Especificidad , Factores Sexuales , Troponina I/normas , Troponina T/normas
9.
Dis Markers ; 2017: 9306409, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28804199

RESUMEN

BACKGROUND: This study evaluates the association between high sensitivity troponin I (hsTnI) and T (hsTnT) and the morphology of coronary artery plaques detected by coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD). METHODS: Patients undergoing CCTA were prospectively enrolled. CCTA was indicated by a low to intermediate pretest probability for CAD during routine clinical care. Within 24 hours of CCTA examination, peripheral blood samples were taken to measure hsTnI, hsTnT, and N-terminal probrain natriuretic peptide (NT-proBNP). RESULTS: A total of 99 patients were enrolled with 43% without CAD, 9% with noncalcified plaques, 28% with calcified plaques, and 19% with mixed type plaque lesions. Both hsTnI and hsTnT levels were able to discriminate significantly between the groups, especially in the presence of mixed coronary plaques (AUC range: 0.741-0.752; p = 0.0001). In multivariate logistic regression models, hsTnT, but not hsTnI, was still significantly associated with mixed coronary plaque morphology (odds ratio = 8.968; 95% CI 1.999-40.241; p = 0.004). CONCLUSIONS: Both hsTnI and hsTnT are able to discriminate between different coronary artery plaques morphologies, whereas hsTnT was significantly associated with mixed coronary plaques in patients with suspected CAD. This trial is registered with NCT03074253.


Asunto(s)
Enfermedad de la Arteria Coronaria/sangre , Placa Aterosclerótica/sangre , Troponina I/sangre , Troponina T/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Placa Aterosclerótica/clasificación , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Sensibilidad y Especificidad , Troponina I/normas , Troponina T/normas
10.
Clin Chem Lab Med ; 55(11): 1675-1682, 2017 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-28593872

RESUMEN

Implementation of the 99th percentile as the upper reference limit for cardiac troponin (cTn) assays is a seemingly lucid recommendation, but, in reality, is incredibly complex. Lack of harmonization between cTn assays diminishes the ability to have a single medical decision point across manufacturer assay/instruments. Moreover, even within a single cTn assay there are several published values corresponding to the "99th percentile". Variability in the determined value is primarily a function of population selection including: sample size, age, sex, exclusion criteria, and statistical methods. Given the complexities associated with this value, some countries have taken an expert consensus approach to endorsing harmonized, assay-specific, cTn 99th percentile values. The purpose of this manuscript is to highlight the intricacies associated with selecting a cTn 99th percentile and to review the approach that Australia used to endorse a nationwide upper reference limit for the Architect STAT hs-cTnI assay.


Asunto(s)
Troponina/análisis , Bioensayo/normas , Intervalos de Confianza , Humanos , Límite de Detección , Infarto del Miocardio/diagnóstico , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Sensibilidad y Especificidad , Troponina/normas , Troponina I/análisis , Troponina I/normas , Troponina T/análisis , Troponina T/normas
11.
Clin Chem Lab Med ; 55(11): 1634-1651, 2017 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-28599373

RESUMEN

According to recent international guidelines, including the 2012 Third Universal Definiton of Myocardial Infarction by the Joint ESC/ACCF/AHA/WHF Task Force, an increase in cardiac troponin (cTn) levels over the 99th percentile upper reference limit (99th URL) should be considered clinically relevant, this cut-off being measured with an imprecision ≤10 CV%. In theory 99th URL values strongly depend not only on demographic and physiological variables (i.e. criteria for considering the reference population "healthy"), but also on the analytical performance of cTn methods and mathematical algorithms used for the calculation. The aim of the present article was therefore to review the methodological and pathophysiological factors affecting the evaluation and calculation of the 99th URL for cTn assay. The critical analysis made showed that no uniform procedure is followed, and nor have experts or regulatory bodies provided uniform guidelines for researchers or cTn assays manufacturers as an aid in "their quest to define normality". In particular, little attention has been paid to the way in which a healthy reference population is to be selected, or the criteria for calculating the 99th URL value for cTn assays, thus highlighting the need for international recommendations not only for demographic and physiological variables criteria for defining a healthy reference population, but also for calculating mathematical algorithms for establishing/calculating clinical decision values. An expert consensus group, comprising laboratory and clinical scientists, biomedical statisticians, industrial and regulatory representatives, should be responsible for drawing up these guidelines.


Asunto(s)
Troponina I/análisis , Troponina T/análisis , Factores de Edad , Biomarcadores/análisis , Cardiopatías/metabolismo , Cardiopatías/patología , Humanos , Inmunoensayo/normas , Valores de Referencia , Factores Sexuales , Troponina I/normas , Troponina T/normas
13.
Clin Chem Lab Med ; 55(11): 1798-1804, 2017 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-28375843

RESUMEN

BACKGROUND: A multitude of troponin assays for the point-of-care (POC) have been developed showing a lack of analytical sensitivity and precision. We present a new platform solution for the high-sensitivity detection of cardiac troponin T (cTnT) in a 30 µL whole blood sample with a turnaround time of 11 min. METHODS: The immunoassay was completely run in a ready-to-use plastic disposable, a centrifugal microfluidic disc with fully integrated reagents. After the sample application, the assay was automatically processed by separating the cellular blood components via centrifugation, followed by incubation of a defined volume from the generated plasma with the immunoreagents. The fluorescence in the signal zone of a membrane was measured after its washing for the cTnT quantitation. RESULTS: A calibration curve, measured in whole blood samples spiked with native human cTnT, was generated covering a range up to a concentration of approximately 8300 ng/L. The lower detection limit was determined to be 3.0 ng/L. At a concentration of 14 ng/L, the 99th percentile value from the high-sensitivity cardiac troponin T (hs-cTnT) assay in the Elecsys® system, the imprecision (CV) was 3.8%. A CV profile indicated that the functional sensitivity for a CV <10% was 6.8 ng/L. The assay did not show any significant cross-reaction with human skeletal troponin T. We observed an excellent correlation with the hs-TnT Elecsys® assay for 49 clinical plasma samples (r=0.9744). CONCLUSIONS: The described technology shows that an analytical performance for a highly sensitive determination of cTnT can be achieved in a POC setting.


Asunto(s)
Inmunoensayo , Troponina T/sangre , Calibración , Guías como Asunto , Humanos , Inmunoensayo/normas , Límite de Detección , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto , Juego de Reactivos para Diagnóstico , Troponina T/normas
15.
Diagnosis (Berl) ; 3(4): 189-198, 2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29536905

RESUMEN

High sensitive cardiac troponin assays have become the gold standard in the diagnosis of an acute type 1 myocardial infarction (MI) in the absence of ST-segment elevation. Several acute or chronic conditions that impact cardiac troponin levels in the absence of a MI might lead to a misdiagnosis of MI. For example, patients with impaired renal function as well as elderly patients often present with chronically increased cardiac troponin levels. Therefore, the diagnosis of MI type 1 based on the 99th percentile upper limit of normal threshold is more difficult in these patients. Different diagnostic approaches might help to overcome this limitation of reduced MI specificity of sensitive troponin assays. First, serial troponin measurement helps to differentiate chronic from acute troponin elevations. Second, specific diagnostic cut-offs, optimized for a particular patient group, like elderly patients, are able to regain specificity. Such an individualized use and interpretation of sensitive cardiac troponin measurements improves diagnostic accuracy and reduces the amount of misdiagnosed MI type 1.


Asunto(s)
Errores Diagnósticos/prevención & control , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina I/sangre , Troponina T/sangre , Enfermedad Aguda , Algoritmos , Biomarcadores/sangre , Electrocardiografía , Humanos , Infarto del Miocardio/sangre , Infarto del Miocardio/clasificación , Infarto del Miocardio/fisiopatología , Infarto del Miocardio sin Elevación del ST/sangre , Infarto del Miocardio sin Elevación del ST/fisiopatología , Factores de Riesgo , Sensibilidad y Especificidad , Troponina I/normas , Troponina T/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...