Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.327
Filtrar
1.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715080

RESUMEN

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Asunto(s)
Válvula Aórtica , Anomalías de los Vasos Coronarios , Ecocardiografía Transesofágica , Válvula Mitral , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/anomalías , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Anomalías de los Vasos Coronarios/cirugía , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria , Angiografía por Tomografía Computarizada , Masculino , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Femenino , Vasos Coronarios/cirugía , Vasos Coronarios/diagnóstico por imagen
2.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722121

RESUMEN

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Asunto(s)
Válvula Aórtica , Ecocardiografía Transesofágica , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía
3.
Clin Interv Aging ; 19: 695-703, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711477

RESUMEN

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Complicaciones Posoperatorias , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Anciano , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Persona de Mediana Edad , Factores de Riesgo , Enfermedades de las Válvulas Cardíacas/cirugía
4.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38565982

RESUMEN

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Asunto(s)
Estenosis de la Válvula Aórtica , Aprendizaje Profundo , Impresión Tridimensional , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Stents , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen
5.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577939

RESUMEN

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Factores de Tiempo , Anciano , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Recuperación de la Función , Hemodinámica , Medición de Riesgo
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38608189

RESUMEN

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Masculino , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Adulto , Femenino , Insuficiencia de la Válvula Aórtica/cirugía , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Reoperación/estadística & datos numéricos , Enfermedades de las Válvulas Cardíacas/cirugía , Adulto Joven , Estudios de Seguimiento
7.
Comput Methods Programs Biomed ; 250: 108173, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38615386

RESUMEN

BACKGROUND AND OBJECTIVE: The conventional valve stents that are cylindrical in shape will become elliptical when implanted in bicuspid aortic valve, thereby reducing the durability of the artificial valve. In this study, a new design of valve stent is presented where valve stents have elliptical cross-section at the annulus and it is expected to have better expandability and circle shape during the interaction between the stent and bicuspid aortic valve, thereby extending the durability of artificial valve. METHODS: Finite element method (FEM) is used to study the mechanical behavior of the novel valve stent in the bicuspid aortic valve. The effects of three matching relationship between the ellipticity of the stents and the ellipticity of the annulus (i.e., the ellipticity of the stent is greater than, equal to and less than the annulus ellipticity, respectively) on the mechanical behavior of stent expansion are studied. In addition, the expansion mechanical behavior of the novel valve stent at different implantation depths is also compared. RESULTS: Results indicate that novel valve stent implantation with elliptical features is superior to conventional circular valve stent. When the novel valve stent ellipticity is less than the annulus ellipticity, the ellipticity of the novel valve stent after implantation is smaller than that of the conventional circular valve stent. This indicated that the novel valve stent has better expandability and post-expansion shape, making artificial valve to have better durability. The risk of paravalvular leak after implantation is lowest when the novel valve stent ellipticity is less than annulus ellipticity. When the novel valve stent ellipticity coincides with annulus ellipticity, the aortic wall is subjected to greatest stress. With the increase of implantation depth, the stress on the novel valve stent decrease. CONCLUSIONS: This study might provide insights for improving stent design for bicuspid aortic valve.


Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Análisis de Elementos Finitos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Stents , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Humanos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estrés Mecánico , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedad de la Válvula Aórtica/cirugía
8.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38686682

RESUMEN

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Ecocardiografía Transesofágica , Cardiopatías Congénitas , Hallazgos Incidentales , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Implantación de Prótesis de Válvulas Cardíacas , Ecocardiografía Doppler en Color
9.
Echocardiography ; 41(4): e15817, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38648213

RESUMEN

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital disease. The clinical characteristics of this disease remain unclear except for those in relatively young patients reported from tertiary referral hospitals. The aim of this study was to determine the clinical features of QAV in a regional population. METHODS AND RESULTS: We retrospectively investigated 25 340 consecutive patients over middle age (median age, 73 (IQR 65-80) years; range, 45-102 years) who underwent transthoracic echocardiography (TTE) at our institute during the period from April 2008 to December 2023. Eight (0.032%) of the patients (median age, 65 years; range, 47-91 years) were diagnosed with QAV. Six patients suffered from aortic regurgitation (AR), and one patient had mild aortic stenosis at the time of QAV diagnosis. Two patients who had severe AR at referral underwent aortic valve surgery. The severity of AR in the other patients was moderate or less. During a median follow-up period of 27 months (range, 1-171 months), none of the patients other than above two patients had cardiac events. One patient died from a non-cardiac cause at 94 years of age. CONCLUSIONS: Patients diagnosed with QAV after middle age, who do not exhibit severe valve insufficiency at the time of diagnosis, may not experience worse clinical outcomes. However, further research is required for a better understanding of the long-term outcomes.


Asunto(s)
Válvula Aórtica , Ecocardiografía , Humanos , Femenino , Masculino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Ecocardiografía/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Estudios de Seguimiento
12.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38561108

RESUMEN

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Sistema de Registros , Humanos , Masculino , Femenino , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Persona de Mediana Edad , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/epidemiología , Adulto , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Seguimiento , Italia/epidemiología
13.
Comput Biol Med ; 172: 108191, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38457932

RESUMEN

Bicuspid aortic valve (BAV), the most common congenital heart disease, is prone to develop significant valvular dysfunction and aortic wall abnormalities such as ascending aortic aneurysm. Growing evidence has suggested that abnormal BAV hemodynamics could contribute to disease progression. In order to investigate BAV hemodynamics, we performed 3D patient-specific fluid-structure interaction (FSI) simulations with fully coupled blood flow dynamics and valve motion throughout the cardiac cycle. Results showed that the hemodynamics during systole can be characterized by a systolic jet and two counter-rotating recirculation vortices. At peak systole, the jet was usually eccentric, with asymmetric recirculation vortices and helical flow motion in the ascending aorta. The flow structure at peak systole was quantified using the vorticity, flow rate reversal ratio and local normalized helicity (LNH) at four locations from the aortic root to the ascending aorta. The systolic jet was evaluated with the peak velocity, normalized flow displacement, and jet angle. It was found that peak velocity and normalized flow displacement (rather than jet angle) gave a strong correlation with the vorticity and LNH in the ascending aorta, which suggests that these two metrics could be used for clinical noninvasive evaluation of abnormal blood flow patterns in BAV patients.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Aorta , Hemodinámica/fisiología
14.
Zhonghua Wai Ke Za Zhi ; 62(5): 393-399, 2024 May 01.
Artículo en Chino | MEDLINE | ID: mdl-38548607

RESUMEN

Objective: To examine the early to mid-term clinical outcomes of aortic valve repair in patients with bicuspid aortic insufficiency. Methods: This is a retrospective cohort study. The clinical data of 124 patients with BAV insufficiency who underwent aortic valve repair from January 2017 to June 2023 in the Department of Cardiovascular Surgery at Fuwai Hospital were analyzed retrospectively. There were 117 males and 7 females with an age of (38.1±12.7) years (range: 14 to 65 years). Depending on whether the aortic sinus was replaced or not, surgical approaches were divided into valve sparing root replacement (reimplantation, remodeling, modified remodeling) and isolated aortic valve repair (annuloplasty, isolated aortic valve leaflet repair). Perioperative and follow-up data were collected. Kaplan-Meier method was used to plot the curves of survival rate, free recurrence rate of massive aortic valve insufficiency and free re-operation rate, and Log-rank test was used for comparison between groups. Results: Among the surgeries, there were 47 cases of reimplantation, 8 cases of remodeling, 8 cases of modified remodeling, 48 cases of aortic annuloplasty (external annuloplasty in 22 cases, CV-0 annuloplasty in 26 cases), and 13 cases of isolated leaflet repair. Leaflet plication was the most used leaflet repair technique, used in 103 patients. The cardiopulmonary bypass time was (133.7±56.9) minutes (range: 48 to 461 minutes), and aortic cross-clamp time was (103.8±47.8) minutes (range: 25 to 306 minutes), with no surgical mortality. All patients underwent outpatient or telephone follow-up. The cumulative follow-up time was 340.3 person-years and the mean follow-up time was (M (IQR)) 34.0 (25.5) months (range: 3 to 76 months). The 5-year survival rate was 98.4%, the 5-year freedom from significant insufficiency rate was 93.4% and the 5-year freedom from aortic valve reoperation rate was 95.6%. The subgroup analysis revealed a significantly better freedom from the significant insufficiency rate in the aortic valve annular reduction group compared to the non-reduction group (P<0.01). Conclusions: Aortic valve repair in patients with bicuspid aortic insufficiency could obtain steady early to mid-term outcomes. Aortic annuloplasty can reduce the risk of recurrent aortic valve insufficiency in patients undergoing aortic repair.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Masculino , Femenino , Adulto , Estudios Retrospectivos , Persona de Mediana Edad , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Adolescente , Adulto Joven , Resultado del Tratamiento , Anciano , Enfermedades de las Válvulas Cardíacas/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Tasa de Supervivencia
15.
J Cardiothorac Surg ; 19(1): 54, 2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38311727

RESUMEN

BACKGROUND: Anomalous aortic origin of the coronary artery (AAOCA) is a rare congenital heart disease. Therefore, optimal indications for surgery in patients with severe aortic valve stenosis (AS) complicated by AAOCA remain uncertain. CASE PRESENTATION: We report the case of a 57-year-old male patient who underwent aortic valve replacement (AVR) and aortic root enlargement using a Y-incision procedure for severe AS with an anomalous aortic origin of the right coronary artery (AAORCA). Since preoperative single-photon emission computed tomography revealed no ischaemic lesions, an aortic root enlargement with a Y-incision was performed to prevent the potential compression of the prosthetic valve on the AAOCA and prosthesis-patient mismatch. CONCLUSIONS: Preoperative evaluation of the coronary anatomy and myocardial ischaemia using advanced imaging modalities and aortic root enlargement with the Y-incision procedure is an effective strategy for preventing ischaemic complications in cases of severe AS with AAORCA.


Asunto(s)
Estenosis de la Válvula Aórtica , Anomalías de los Vasos Coronarios , Implantación de Prótesis de Válvulas Cardíacas , Masculino , Humanos , Persona de Mediana Edad , Aorta Torácica/cirugía , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Implantación de Prótesis de Válvulas Cardíacas/métodos
16.
Echocardiography ; 41(1): e15739, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38284678

RESUMEN

Bicuspid aortic valve is the most common congenital heart defect. Transthoracic echocardiogram is the initial tool to assess and diagnose this condition, however, transesophageal echocardiogram with 3D modalities, including transillumination have a better anatomical and functional evaluation of the valve, allowing to classify the bicuspid aortic valve according to the position of the raphe and assess the main vessels for complications or exclude other cardiovascular diseases.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Transiluminación , Ecocardiografía , Ecocardiografía Transesofágica
17.
Future Cardiol ; 20(1): 5-10, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38189260

RESUMEN

Unicuspid aortic valve (UAV) is a rare congenital cardiac anomaly. There are two forms of UAV, including unicuspid acommissural and unicuspid unicommissural. Definitive management for UAV is surgical intervention, but due to the rarity of UAV, the long-term surgical outcomes as well as overall prognosis are not known. Here, we present the case of a 19-year-old patient who was found to have a UAV prenatally and underwent a mechanical aortic valve replacement through an upper hemi-sternotomy due to elevated aortic stenosis gradients and presence of symptoms.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Adulto Joven , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía
18.
Cardiol Young ; 34(2): 462-464, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38167172

RESUMEN

Atresia of the aortic valve is usually associated with hypoplasia of the mitral valve and the left ventricle. In very rare cases, a ventricular septal defect may be associated with aortic atresia, when left ventricle and mitral valve are normal-sized, due to the presence of an outflow for the left ventricle through the ventricular septal defect. We present the multi-modality imaging findings of an adolescent girl who presented with breathlessness and was later found to have aortic valvar atresia with a normal-sized left ventricle.


Asunto(s)
Defectos del Tabique Interventricular , Ventrículos Cardíacos , Femenino , Humanos , Adolescente , Ventrículos Cardíacos/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Válvula Mitral , Disnea
19.
J Cardiovasc Comput Tomogr ; 18(2): 179-186, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38262851

RESUMEN

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital heart disease with a limited body of literature. This retrospective cohort study investigates QAV morphology, function, and clinical outcomes. METHODS: Echocardiography was used to assess valvular function. Morphological characteristics such as phenotypes, raphe, regurgitant orifice area (ROA), and aortic dilation (diameter >40 â€‹mm) were assessed by cardiac CT. Patients were followed up for the combined event of all-cause death and aortic valve replacement (AVR). RESULTS: Ninety QAV patients (screened from 322385 CT scans) were included (mean age 55.2 â€‹± â€‹13.6 years, 61.1 â€‹% male). Isolated significant aortic regurgitation (AR) was present in 75.6 â€‹% of patients. The cohort was dominated by type I (four equal leaflets, 37.8 â€‹%) and type II (3 larger and 1 smaller leaflets, 42.2 â€‹%) QAV. Fused raphe was present in 26.7 â€‹% of patients. ROACT was correlated with AR severity and aortic dilation (41.1 â€‹%, n â€‹= â€‹37). Among patients without AVR at baseline (n â€‹= â€‹60), one died and 17 underwent AVR during a median follow-up of 35.0 months (IQR:17.3-62.8). ROACT was associated with an increasing risk of combined event (as a categorical variable with a cut-off of 21.4 â€‹mm2, HR â€‹= â€‹4.25, 95%CI 1.49-12.17, p â€‹= â€‹0.007; as a continuous variable (per mm2 increment), HR â€‹= â€‹1.04, 95%CI 1.01-1.07, p â€‹= â€‹0.003). Additionally, ROACT had incremental prognostic value when added to the AR severity model (area under the receiver-operating characteristic curve increased from 86.8 to 88.4, p â€‹= â€‹0.004). CONCLUSION: QAV is characterized by variable anatomy, progressive AR, concomitant cusp fusion and aortic enlargement. ROACT may be a potential ancillary prognostic marker in patients with QAV.


Asunto(s)
Enfermedades de la Aorta , Insuficiencia de la Válvula Aórtica , Válvula Aórtica Cuadricúspide , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Hemodinámica
20.
Circulation ; 149(20): 1578-1597, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38258575

RESUMEN

BACKGROUND: Calcification of the aortic valve leads to increased leaflet stiffness and consequently results in the development of calcific aortic valve disease (CAVD). However, the underlying molecular and cellular mechanisms of calcification remain unclear. Here, we identified a novel aortic valve calcification-associated PIWI-interacting RNA (piRNA; AVCAPIR) that increases valvular calcification and promotes CAVD progression. METHODS: Using piRNA sequencing, we identified piRNAs contributing to the pathogenesis of CAVD that we termed AVCAPIRs. High-cholesterol diet-fed ApoE-/- mice with AVCAPIR knockout were used to examine the role of AVCAPIR in aortic valve calcification (AVC). Gain- and loss-of-function assays were conducted to determine the role of AVCAPIR in the induced osteogenic differentiation of human valvular interstitial cells. To dissect the mechanisms underlying AVCAPIR-elicited procalcific effects, we performed various analyses, including an RNA pulldown assay followed by liquid chromatography-tandem mass spectrometry, methylated RNA immunoprecipitation sequencing, and RNA sequencing. RNA pulldown and RNA immunoprecipitation assays were used to study piRNA interactions with proteins. RESULTS: We found that AVCAPIR was significantly upregulated during AVC and exhibited potential diagnostic value for CAVD. AVCAPIR deletion markedly ameliorated AVC in high-cholesterol diet-fed ApoE-/- mice, as shown by reduced thickness and calcium deposition in the aortic valve leaflets, improved echocardiographic parameters (decreased peak transvalvular jet velocity and mean transvalvular pressure gradient, as well as increased aortic valve area), and diminished levels of osteogenic markers (Runx2 and Osterix) in aortic valves. These results were confirmed in osteogenic medium-induced human valvular interstitial cells. Using unbiased protein-RNA screening and molecular validation, we found that AVCAPIR directly interacts with FTO (fat mass and obesity-associated protein), subsequently blocking its N6-methyladenosine demethylase activity. Further transcriptomic and N6-methyladenosine modification epitranscriptomic screening followed by molecular validation confirmed that AVCAPIR hindered FTO-mediated demethylation of CD36 mRNA transcripts, thus enhancing CD36 mRNA stability through the N6-methyladenosine reader IGF2BP1 (insulin-like growth factor 2 mRNA binding protein 1). In turn, the AVCAPIR-dependent increase in CD36 stabilizes its binding partner PCSK9 (proprotein convertase subtilisin/kexin type 9), a procalcific gene, at the protein level, which accelerates the progression of AVC. CONCLUSIONS: We identified a novel piRNA that induced AVC through an RNA epigenetic mechanism and provide novel insights into piRNA-directed theranostics in CAVD.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , ARN Interferente Pequeño , Animales , Calcinosis/metabolismo , Calcinosis/genética , Calcinosis/patología , Válvula Aórtica/metabolismo , Válvula Aórtica/patología , Válvula Aórtica/anomalías , Humanos , Ratones , Estenosis de la Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/genética , Estenosis de la Válvula Aórtica/patología , ARN Interferente Pequeño/metabolismo , ARN Interferente Pequeño/genética , Masculino , Osteogénesis , Ratones Endogámicos C57BL , Ratones Noqueados , Modelos Animales de Enfermedad , Enfermedad de la Válvula Aórtica/metabolismo , Enfermedad de la Válvula Aórtica/genética , Enfermedad de la Válvula Aórtica/patología , ARN de Interacción con Piwi
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...