Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 255
Filtrar
1.
Ann Thorac Surg ; 114(2): e109-e111, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34921817

RESUMEN

Traumatic aortic valve regurgitation is a rare but potentially fatal complication of blunt chest trauma. We present the case of a 68-year-old woman who suffered from severe traumatic aortic valve regurgitation after a car accident. The patient was successfully treated by surgical replacement of the aortic valve with a biologic prosthesis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Traumatismos Torácicos , Heridas no Penetrantes , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/lesiones , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Femenino , Humanos , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/diagnóstico , Traumatismos Torácicos/cirugía , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico , Heridas no Penetrantes/cirugía
2.
Med Sci Monit ; 27: e930596, 2021 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-34433799

RESUMEN

BACKGROUND The aim of this study was to measure sleep quality among patients who underwent infective endocarditis (IE) surgery and identify the risk factors involved in sleep disorders. MATERIAL AND METHODS In this study, we used actigraphy, the Pittsburgh Sleep Quality Index (PSQI), and Epworth Sleep Scale (ESS) to determine the clinical characteristics of sleep disorders in 116 patients with IE who were in rehabilitation after surgery. RESULTS Our results showed that 46 (39.7%) patients had sleep efficiency over 85%, while 70 (60.3%) patients had sleep efficiency below 85%. The correlation analysis showed that sleep efficiency was related to the duration of the disease, with a longer duration leading to lower sleep efficiency (P=0.031). The sleep efficiency of patients with IE following surgery was also affected by alcohol consumption; however, surprisingly, patients with "heavy" alcohol consumption had higher sleep efficiency (P=0.030). We found a significant correlation between sleep efficiency and postoperative interleukin-6 (IL) levels, C-reactive protein (CRP) levels, and preoperative erythrocyte sedimentation rate (P<0.05). No significant correlation was found between brain natriuretic peptide levels and sleep efficiency, PSQI score, or ESS score. Postoperative hemoglobin (Hb) level was associated with sleep efficiency (R=0.194, P=0.036), but there was no statistically significant correlation between the PSQI and ESS scores. Postoperative alanine transaminase (ALT) showed a significant negative correlation with sleep efficiency (R=-0.27, P=0.003). CONCLUSIONS We found a high prevalence of sleep disorders in patients with IE along with an increase in inflammatory factors, including postoperative IL-6, CRP, ALT, and Hb levels.


Asunto(s)
Válvula Aórtica/cirugía , Cateterismo Cardíaco/efectos adversos , Endocarditis/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/patología , Trastornos del Sueño-Vigilia/patología , Adulto , Válvula Aórtica/lesiones , Endocarditis/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Trastornos del Sueño-Vigilia/etiología , Encuestas y Cuestionarios
4.
Vasc Endovascular Surg ; 55(2): 183-185, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32885727

RESUMEN

Although complications associated with endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms are rarely observed above the diaphragm, they could lead to catastrophic outcomes once they develop. Aortic valve perforation is one of those rare and major adverse events. In this report, we describe a case of an 82-year-old woman who suffered aortic valve perforation during EVAR caused by the wire-push technique. Her hemodynamics became unstable during the procedure and did not improve thereafter. Echocardiography performed 8 days after EVAR revealed aortic valve perforation. Surgical intervention was abandoned because her general condition was poor. The patient died 4 months after EVAR due to heart failure. It should be reminded that inadvertent manipulation of the wire can cause aortic valve perforation even during EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Válvula Aórtica/lesiones , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Insuficiencia Cardíaca/etiología , Lesiones Cardíacas/etiología , Hemodinámica , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado Fatal , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/fisiopatología , Humanos
6.
J Card Surg ; 35(3): 656-658, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31945211

RESUMEN

The Bentall procedure using a bioprosthesis-containing conduit carries the risk of structural valve deterioration within the patients' lifetime. Failed aortic bioprosthesis replacement requires a redo aortic root replacement that is associated with significant morbidity and mortality. We describe an original "neo-annulus" technique of aortic valve replacement (AVR) within the Bentall graft. This technique involves an incision of the Bentall valve-containing aortic root conduit, cutting the stainless wireform stent and the inner plastic stent of the bioprosthetic valve at the tips of commissure posts with a wire cutter, removal of semilunar fragments of the remaining stainless wire, division of the fabric of the valve between the valve sewing cuff and the Elgiloy alloy base ring leaving the sewing cuff of the excised aortic valve bioprosthesis attached to the Bentall conduit as a "neo-annulus". Subsequently, this neo-annulus is stitched with interrupted 2/0 Ticrone sutures and another prosthetic aortic valve implanted inside of the old Bentall conduit. The graft incision is closed with a continuous 4/0 polypropylene suture.


Asunto(s)
Válvula Aórtica/lesiones , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Humanos , Masculino , Resultado del Tratamiento
7.
J Card Surg ; 35(1): 204-206, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31573092

RESUMEN

We report a rare case of a 44-year-old male who underwent a diagnostic coronary angiogram following a non-ST elevation myocardial infarction complicated by an aortic valve leaflet tear requiring surgical intervention. Routine transthoracic echocardiogram demonstrated a mobile echogenic structure prolapsing into the left ventricular outflow tract. An intraoperative transesophageal echocardiogram confirmed that the structure originated from the ventricular side of left coronary cusp, causing malcoaptation between left and right coronary cusps, and subsequent moderate to severe aortic regurgitation.


Asunto(s)
Válvula Aórtica/lesiones , Válvula Aórtica/cirugía , Angiografía Coronaria/efectos adversos , Enfermedad Iatrogénica , Enfermedades Raras , Adulto , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Infarto del Miocardio/diagnóstico
10.
Heart Surg Forum ; 22(5): E372-E374, 2019 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-31596714

RESUMEN

As a bridge to heart transplantation or destination treatment, implantation of the Heartmate 3 (HM3) left ventricular assist device is a viable option for patients with end-stage congestive heart failure. The recent Momentum 3 trial has shown favorable outcomes compared with Heartmate 2. We report the first case of aortic root thrombus occurring early after HM3 implantation as a bridge to heart transplantation. Our case suggests that bridging with an Impella 5.0 preceding HM3 implantation could potentially predispose patients to aortic root thrombus after HM3 implantation, due to Impella-related injury to the aortic valve and aortic root stasis after durable LVAD support.


Asunto(s)
Aorta/lesiones , Válvula Aórtica/lesiones , Enfermedades de las Válvulas Cardíacas/etiología , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/etiología , Trombosis/etiología , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Trombosis/diagnóstico por imagen , Trombosis/cirugía
12.
Radiologia (Engl Ed) ; 61(4): 341-344, 2019.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31101327

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an alternative to surgical valve replacement in patients with high surgical risk. Although TAVI is becoming more and more common, it is not without complications. Rupture of the aortic root after implantation is an uncommon, but lethal complication; few cases have been described in the literature. Multidetector computed tomography is fundamental before TAVI to evaluate factors that predispose to complications; however, its role after the procedure is still controversial.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/lesiones , Lesiones Cardíacas/diagnóstico por imagen , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Lesiones Cardíacas/etiología , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Rotura/diagnóstico por imagen , Rotura/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
13.
Eur Heart J ; 40(39): 3248-3259, 2019 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-30945735

RESUMEN

AIMS: The pathogenesis of endocarditis is not well understood resulting in unsuccessful attempts at prevention. Clinical observations suggest that Staphylococcus aureus infects either damaged or inflamed heart valves. Using a newly developed endocarditis mouse model, we therefore studied the initial adhesion of S. aureus in both risk states. METHODS AND RESULTS: Using 3D confocal microscopy, we examined the adhesion of fluorescent S. aureus to murine aortic valves. To mimic different risk states we either damaged the valves with a surgically placed catheter or simulated valve inflammation by local endothelium activation. We used von Willebrand factor (VWF) gene-deficient mice, induced platelet and fibrinogen depletion and used several S. aureus mutant strains to investigate the contribution of both host and bacterial factors in early bacterial adhesion. Both cardiac valve damage and inflammation predisposed to endocarditis, but by distinct mechanisms. Following valve damage, S. aureus adhered directly to VWF and fibrin, deposited on the damaged valve. This was mediated by Sortase A-dependent adhesins such as VWF-binding protein and Clumping factor A. Platelets did not contribute. In contrast, upon cardiac valve inflammation, widespread endothelial activation led to endothelial cell-bound VWF release. This recruited large amounts of platelets, capturing S. aureus to the valve surface. Here, neither fibrinogen, nor Sortase A were essential. CONCLUSION: Cardiac valve damage and inflammation predispose to S. aureus endocarditis via distinct mechanisms. These findings may have important implications for the development of new preventive strategies, as some interventions might be effective in one risk state, but not in the other.


Asunto(s)
Válvula Aórtica/microbiología , Adhesión Bacteriana , Endocarditis Bacteriana/microbiología , Inflamación/complicaciones , Infecciones Estafilocócicas/complicaciones , Staphylococcus aureus/fisiología , Animales , Válvula Aórtica/lesiones , Plaquetas , Coagulasa/metabolismo , Modelos Animales de Enfermedad , Endocarditis Bacteriana/metabolismo , Endotelio/metabolismo , Femenino , Fibrina/metabolismo , Inflamación/metabolismo , Masculino , Ratones , Glicoproteínas de Membrana Plaquetaria/metabolismo , Infecciones Estafilocócicas/metabolismo , Staphylococcus aureus/metabolismo , Factor de von Willebrand/genética , Factor de von Willebrand/metabolismo
14.
Heart ; 105(5): 398-422, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30442744

RESUMEN

A 29-year-old man crashed at high speed into another vehicle at traffic lights. He was able to get out of his van but then collapsed after running a few metres. On arrival in the emergency department he was conscious, with a pulse of 140 beats/min and blood pressure of 110/32 mm Hg. He had collapsing arterial pulses and an early diastolic murmur. He had a chest radiograph (figure 1A) and a skeletal survey which demonstrated multiple fractures, involving his left hand, right femur, right calcaneus, and left first and second ribs. A CT scan of the thorax was performed with a radiological contrast agent but without gated images because of the tachycardia (Figure 1B). The blood pressure and pulse were attributed to blood loss into the right thigh. Urgent cardiology review and bedside echocardiography were requested before he had emergency orthopaedic surgery (figure 1C, D) (online supplementary video 1).DC1SP110.1136/heartjnl-2018-314082.supp1Supplementary file 1heartjnl;105/5/398/F1F1F1Figure 1(A-D) Chest radiograph, CT thorax with contrast, parasternal long-axis transthoracic view (grey scale) and with colour flow. The arrow in section C highlights the area of significance (mobile linear structure). QUESTION: What is the most likely diagnosis?Traumatic dissection of the aortic root.Subaortic membrane or diaphragm.Traumatic transection of the aorta.Traumatic rupture of the aortic valve.Myocardial rupture.


Asunto(s)
Válvula Aórtica , Ecocardiografía Transesofágica/métodos , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Accidentes de Tránsito , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/lesiones , Válvula Aórtica/fisiopatología , Diagnóstico Diferencial , Humanos , Masculino , Rotura/diagnóstico , Rotura/etiología , Rotura/fisiopatología
15.
J Clin Ultrasound ; 47(3): 175-177, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30443912

RESUMEN

Iatrogenic aortic valve injury after mitral valve surgery is a well-known but rare complication. Herein, we report a 62-year-old male patient who underwent mitral valve replacement surgery 12 years ago and developed moderate to severe aortic regurgitation immediately after surgery.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Válvula Aórtica/lesiones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/cirugía
16.
J Cardiothorac Vasc Anesth ; 33(6): 1584-1587, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30467028

RESUMEN

The Impella (Abiomed, Danvers, MA) is a minimally invasive transvalvular left ventricular assist device (LVAD) that effectively unloads the left ventricle (LV), especially in patients with ventricular arrhythmias in the setting of a venous-arterial extracorporeal membrane oxygenator (VA ECMO).1,2 Utilization of the Impella device has increased significantly in the last few years for high-risk percutaneous coronary intervention and cardiogenic shock because of its relatively easy implantation in the catheterization lab and the operating room. Although rare, iatrogenic injury of the aortic valve (AV) can be caused by placement of the device across the AV.3 This can lead to aortic regurgitation (AR) with significant clinical consequences in the setting of cardiogenic shock. This AR can be challenging to diagnose echocardiographically because of the artifacts generated by the device when using color-flow Doppler. In this E-challenge, the authors emphasize the importance of recognizing these findings for accurate interpretation of the echocardiogram in the management of cardiogenic shock refractory to the Impella LVAD and the utility of transesophageal echocardiography (TEE).


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico , Válvula Aórtica/diagnóstico por imagen , Artefactos , Errores Diagnósticos , Ecocardiografía Doppler en Color/métodos , Lesiones Cardíacas/diagnóstico , Corazón Auxiliar/efectos adversos , Válvula Aórtica/lesiones , Insuficiencia de la Válvula Aórtica/etiología , Lesiones Cardíacas/complicaciones , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/cirugía
17.
Kyobu Geka ; 71(12): 1027-1030, 2018 11.
Artículo en Japonés | MEDLINE | ID: mdl-30449872

RESUMEN

A 40-year-old man presented to our hospital with fever and slight palpitation. The echocardiogram revealed bicuspid aortic valve, massive aortic regurgitation, and aneurysm of Valsalva sinus. Operative findings showed an aortic root pseudoaneurysm originating just below the avulsion of the right to left commissure. The orifice was closed with a part of a woven vascular graft, and the aortic valve was replaced with a mechanical valve. There was no sign of marked inflammation, although pathophysiologic findings indicated infective endocarditis. His postoperative course was uneventful.


Asunto(s)
Aneurisma Falso/etiología , Válvula Aórtica/lesiones , Endocarditis Bacteriana/complicaciones , Seno Aórtico , Adulto , Aneurisma Falso/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Rotura Espontánea/etiología , Rotura Espontánea/cirugía
18.
Ann Card Anaesth ; 21(4): 442-443, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30333345

RESUMEN

Catheter insertion in central vein can potentially cause accidental arterial injury. However it is very unusual to see such catheter in aorta causing aortic regurgitation. Pressure monitoring and Ultrasound guidance can reliably prevent accidental arterial puncture.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Cateterismo Venoso Central/efectos adversos , Válvula Aórtica/lesiones , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/cirugía , Arteria Carótida Interna/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Humanos , Persona de Mediana Edad , Monitoreo Fisiológico , Ultrasonografía Intervencional
19.
Kyobu Geka ; 71(8): 626-629, 2018 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-30185762

RESUMEN

A 61-year-old man with a history of hypertension and cerebral infarction, presented to a clinic with sudden dyspnea at rest. He was diagnosed with heart failure and referred to our hospital. Echocardiography and three-dimensional computed tomography showed acute heart failure and aortic insufficiency due to avulsion of the aortic valve commissure between the right coronary cusp and the non-coronary cusp. He had no symptoms such as fever or infection and no history of rheumatic disease. He underwent intima fixation of the avulsed commissure and aortic valve replacement using a tissue valve because acute left heart failure was refractory to medical treatment. Postoperative echocardiography demonstrated good left ventricular contraction without any aortic regurgitation. He was discharged on the 35th postoperative day.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Válvula Aórtica/lesiones , Implantación de Prótesis de Válvulas Cardíacas , Enfermedad Aguda , Válvula Aórtica/cirugía , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Función Ventricular Izquierda
20.
Kyobu Geka ; 71(6): 468-471, 2018 Jun.
Artículo en Japonés | MEDLINE | ID: mdl-30042248

RESUMEN

We report a case of traumatic disruption of the aortic root with multisystem trauma. A 45-year-old male was suffered from multiple injuries including subarachnoid hemorrhage, lung contusion, retroperitoneal hematoma and femoral bone fracture caused by a traffic accident. He had a history of 3 cardiac surgeries including repair of atrioventricular septal defect and mitral valve replacement using a mechanical valve. Contrast-enhanced computed tomography (CT) revealed leakage of the contrast medium from the aortic root and a filling defect on the right coronary artery. Because of hemorrhagic complications, emergency operation was avoided. He was operated 2 days after the trauma. Laceration of the left-coronary sinus and the non-coronary sinus was observed. Bentall operation was performed and the right coronary artery( RCA) was bypassed with a saphenous vein graft. He was treated with open fixation of the right femur 14 days after the operation and was discharged 58 days after the 1st operation.


Asunto(s)
Válvula Aórtica/lesiones , Vasos Coronarios/lesiones , Procedimientos Quirúrgicos Vasculares/métodos , Accidentes de Tránsito , Válvula Aórtica/cirugía , Vasos Coronarios/cirugía , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Hematoma/etiología , Humanos , Lesión Pulmonar/etiología , Masculino , Persona de Mediana Edad , Traumatismo Múltiple/etiología , Espacio Retroperitoneal , Hemorragia Subaracnoidea/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...