Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.073
Filtrar
1.
HGG Adv ; 5(1): 100258, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38006208

RESUMEN

Ebstein's anomaly, a rare congenital heart disease, is distinguished by the failure of embryological delamination of the tricuspid valve leaflets from the underlying primitive right ventricle myocardium. Gaining insight into the genetic basis of Ebstein's anomaly allows a more precise definition of its pathogenesis. In this study, two distinct cohorts from the Chinese Han population were included: a case-control cohort consisting of 82 unrelated cases and 125 controls without cardiac phenotypes and a trio cohort comprising 36 parent-offspring trios. Whole-exome sequencing data from all 315 participants were utilized to identify qualifying variants, encompassing rare (minor allele frequency < 0.1% from East Asians in the gnomAD database) functional variants and high-confidence (HC) loss-of-function (LoF) variants. Various statistical models, including burden tests and variance-component models, were employed to identify rare variants, genes, and biological pathways associated with Ebstein's anomaly. Significant associations were noted between Ebstein's anomaly and rare HC LoF variants found in genes related to the matrisome, a collection of extracellular matrix (ECM) components. Specifically, 47 genes with HC LoF variants were exclusively or predominantly identified in cases, while nine genes showed such variants in the probands. Over half of unrelated cases (n = 42) and approximately one-third of probands (n = 12) were found to carry one or two LoF variants in these prioritized genes. These results highlight the role of the matrisome in the pathogenesis of Ebstein's anomaly, contributing to a better understanding of the genetic architecture underlying this condition. Our findings hold the potential to impact the genetic diagnosis and treatment approaches for Ebstein's anomaly.


Asunto(s)
Anomalía de Ebstein , Cardiopatías Congénitas , Humanos , Anomalía de Ebstein/genética , Válvula Tricúspide/patología , Cardiopatías Congénitas/complicaciones , Miocardio/patología , Ventrículos Cardíacos/patología
3.
Catheter Cardiovasc Interv ; 102(7): 1282-1286, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37855198

RESUMEN

Intracardiac masses adhering to the tricuspid valve can occur as a result of right-sided infective endocarditis, malignancy, clot formation in the right atrium, or clots-in-transit passing through the right atrium. Early surgical intervention is recommended for tricuspid valve vegetation in some patients, although open heart surgery is not always an option. Treatment options for right heart thrombi include anticoagulation, thrombolysis, surgical embolectomy, or mechanical aspiration. We present a case series of tricuspid valve debulking using aspiration with the FlowTriever System.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Trombosis , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/patología , Endocarditis Bacteriana/cirugía , Procedimientos Quirúrgicos de Citorreducción , Resultado del Tratamiento
4.
J Lipid Res ; 64(3): 100338, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36736622

RESUMEN

Pathogenic mechanisms in degenerative thoracic aortic aneurysms (TAA) are still unclear. There is an ongoing debate about whether TAAs are caused by uniform or distinct processes, which would obviously have a major impact on future treatment strategies. Clearly, the ultimate outcome of TAA subgroups associated with a tricuspid aortic valve (TAV) or a bicuspid aortic valve (BAV) is the same, namely a TAA. Based on results from our own and others' studies, we decided to compare the different TAAs (TAV and BAV) and controls using a broad array of analyses, i.e., metabolomic analyses, gene expression profiling, protein expression analyses, histological characterization, and matrix-assisted laser desorption ionization imaging. Central findings of the present study are the presence of noncanonical atherosclerosis, pathological accumulation of macrophages, and disturbances of lipid metabolism in the aortic media. Moreover, we have also found that lipid metabolism is impaired systemically. Importantly, all of the above-described phenotypes are characteristic for TAV-TAA only, and not for BAV-TAA. In summary, our results suggest different modes of pathogenesis in TAV- and BAV-associated aneurysms. Intimal atherosclerotic changes play a more central role in TAV-TAA formation than previously thought, particularly as the observed alterations do not follow classical patterns. Atherosclerotic alterations are not limited to the intima but also affect and alter the TAV-TAA media. Further studies are needed to i) clarify patho-relevant intima-media interconnections, ii) define the origin of the systemic alteration of lipid metabolism, and iii) to define valid biomarkers for early diagnosis, disease progression, and successful treatments in TAV-TAAs.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Aórtica/metabolismo , Válvula Aórtica/patología , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/metabolismo , Enfermedades de las Válvulas Cardíacas/patología , Válvula Tricúspide/metabolismo , Válvula Tricúspide/patología , Aorta/metabolismo , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Enfermedad de la Válvula Aórtica Bicúspide/metabolismo , Enfermedad de la Válvula Aórtica Bicúspide/patología , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/patología
5.
Stem Cells Dev ; 32(5-6): 140-151, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36565027

RESUMEN

Stem cell niches have been thoroughly investigated in tissue with high regenerative capacity but not in tissues where cell turnover is slow, such as the human heart. The left AtrioVentricular junction (AVj), the base of the mitral valve, has previously been proposed as a niche region for cardiac progenitors in the adult human heart. In the present study, we explore the right side of the human heart, the base of the tricuspid valve, to investigate the potential of this region as a progenitor niche. Paired biopsies from explanted human hearts were collected from multi-organ donors (N = 12). The lateral side of the AVj, right atria (RA), and right ventricle (RV) were compared for the expression of stem cell niche-related biomarkers using RNA sequencing. Gene expression data indicated upregulation of genes related to embryonic development and extracellular matrix (ECM) composition in the proposed niche region, that is, the AVj. In addition, immunohistochemistry showed high expression of the fetal cardiac markers MDR1, SSEA4, and WT1 within the same region. Nuclear expression of HIF1α was detected suggesting hypoxia. Rare cells were found with the co-staining of the proliferation marker PCNA and Ki67 with cardiomyocyte nuclei marker PCM1 and cardiac Troponin T (cTnT), indicating proliferation of small cardiomyocytes. WT1+/cTnT+ and SSEA4+/cTnT+ cells were also found, suggesting cardiomyocyte-specific progenitors. The expression of the stem cell markers gradually decreased with distance from the tricuspid valve. No expression of these markers was observed in the RV tissue. In summary, the base of the tricuspid valve is an ECM-rich region containing cells with expression of several stem cell niche-associated markers. Co-expression of stem cell markers with cTnT indicates cardiomyocyte-specific progenitors. We previously reported similar data from the base of the mitral valve and thus propose that human adult cardiomyocyte progenitors reside around both atrioventricular valves.


Asunto(s)
Nicho de Células Madre , Válvula Tricúspide , Adulto , Humanos , Válvula Tricúspide/patología , Miocitos Cardíacos/metabolismo , Ventrículos Cardíacos , Biomarcadores/metabolismo
6.
Eur Radiol ; 33(3): 2052-2061, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36284004

RESUMEN

OBJECTIVES: We aimed to evaluate immediate and midterm cardiac remodeling after surgery by cardiac magnetic resonance (CMR) in Ebstein's anomaly (EA), and also to investigate preoperative predictors of right ventricular (RV) normalization. METHODS: We retrospectively analyzed CMR parameters of the whole heart in adult patients with EA before surgery, at discharge and follow-up. RESULTS: A total of 26 patients were included and performed CMR at 7 days (interquartile range, 3-13 days) before surgery. Immediate postoperative CMR was finished at discharge (median: 8 [7-9] days; n = 18) and follow-up CMR at 187 days (interquartile range, 167-356 days; n = 17). RV and right atrial (RA) volumes promptly decreased immediately after surgery and at follow-up (all p < 0.05). RV ejection fraction decreased significantly at discharge (p < 0.05) but recovered at follow-up (p = 0.18). However, RV global longitudinal strain and RA reservoir strain were significantly impaired immediately and midterm after surgery (all p < 0.05). Indexed left ventricular (LV) end-diastolic volume, stroke volume, as well as global longitudinal strain increased from preoperative to follow-up (all p < 0.05). Patients who achieved normalization of RV volumes after surgery had smaller severity index and RV and RA volumes and higher LV ejection fraction and RA reservoir strain at baseline than patients without RV normalization (all p < 0.05). CONCLUSIONS: Reverse biventricular remodeling took place in EA after tricuspid valve surgery. Tricuspid valve reconstruction should be performed before deterioration of RV volume overload and LV function to achieve reverse RV remodeling. Key Points • After removing the volume load of tricuspid regurgitation in Ebstein's anomaly, reverse remodeling was detected by CMR in both left and right heart at midterm follow-up. • Tricuspid valve reconstruction should be performed before deterioration of RV volume overload and LV function to achieve reverse RV remodeling.


Asunto(s)
Anomalía de Ebstein , Insuficiencia Cardíaca , Adulto , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/patología , Anomalía de Ebstein/diagnóstico por imagen , Anomalía de Ebstein/cirugía , Anomalía de Ebstein/patología , Estudios Retrospectivos , Remodelación Ventricular , Función Ventricular Derecha , Espectroscopía de Resonancia Magnética
7.
Acta Chir Belg ; 123(5): 563-565, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35395925

RESUMEN

BACKGROUND AND AIM: Papillary fibroelastoma (PFE) represents only 16% of the benign cardiac tumor and approximately 15% of these are located on the tricuspid valve. MATERIALS AND METHODS: Over a period of 22 years (1999-2021) we observed 75 pts with cardiac tumors at our Center over 9650 pts operated on but only one case of a tricuspid valve PFE in a 69-year-old patient. Trans-thoracic echocardiography demonstrated a mobile mass (20 × 10 mm), adhering to the atrial side of the septal leaflet of the tricuspid valve of unknown origin. In consideration of the mobility of the mass and the consequent high embolic risk, surgical removal was made. The patient underwent surgery through a median sternotomy on CPBP. A 'gelatinous' mass adhering to the tricuspid leaflet was found and completely removed. The postoperative course was uneventful. The pathological diagnosis was PFE. CONCLUSIONS: PFEs of the tricuspid valve are rare entities being in most cases found incidentally. In our experience, the incidence of this tumor in this location is 1/10,000 cases of cardiac surgery. Although most patients are asymptomatic, surgical treatment is nevertheless recommended in consideration of the high embolic risk.


Asunto(s)
Fibroelastoma Papilar Cardíaco , Fibroma , Neoplasias Cardíacas , Humanos , Anciano , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/patología , Fibroelastoma Papilar Cardíaco/patología , Fibroma/diagnóstico por imagen , Fibroma/cirugía , Ecocardiografía , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía
8.
Catheter Cardiovasc Interv ; 100(6): 1134-1137, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36255148

RESUMEN

Marantic endocarditis refers to a noninfectious lesion, usually in the aortic and mitral valves, that is most commonly seen in advanced malignancy and systemic lupus erythematosus. Inflammatory conditions, including antiphospholipid syndrome (APS), are a rare etiology making up less than 20% of reported cases. The condition is thought to be due to a hypercoagulable state and found postmortem with rates in autopsy series ranging from 0.9% to 1.6%. In comparison to infective endocarditis, marantic endocarditis has a greater tendency for valve vegetations to embolize. Common treatment modalities include anticoagulation or valve replacement. Although percutaneous aspiration thrombectomy of right-sided heart chamber thrombi exists, there are limited reports demonstrating its use with regards to treatment of right-sided endocarditis. We present the case of an older male with a history of Factor V Leiden and APS who was admitted due to a rapidly expanding mass on the tricuspid valve (TV). Despite serial blood cultures being negative, the patient received adequate antibiotic therapy for more than 4 weeks. Transthoracic echocardiogram showed an enlarged TV vegetation with an increased diameter from 10 to 30 mm over 6 weeks. Due to the patient's high operative risk and concern for embolization complications, a multidisciplinary decision was made to perform percutaneous aspiration thrombectomy of the TV vegetation. Subsequent biopsy of the lesion confirmed it was noninfectious and nonmalignant. Thus, the patient was started on systemic anticoagulation for prevention of thromboembolic events.


Asunto(s)
Síndrome Antifosfolípido , Endocarditis , Masculino , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/patología , Resultado del Tratamiento , Endocarditis/complicaciones , Síndrome Antifosfolípido/complicaciones , Trombectomía/efectos adversos , Anticoagulantes/uso terapéutico
9.
J Card Surg ; 37(10): 3417-3420, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35842811

RESUMEN

BACKGROUND: Hemostatic disturbances with coronavirus disease 2019 (COVID-19) can predispose to tricuspid and right heart thrombi in very rare instances. AIM: We describe a 29-year-old female patient without a previous cause of thrombosis who developed large tricuspid valve thrombus (TVT) and moderate-to-severe tricuspid regurgitation (TR) during the course of COVID-19 infection. MATERIALS AND METHODS: Persistant fever and tachycardia with thrombocytopenia and high d-dimer increased the index of suspicion. The diagnosis was made by bedside transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR). Surgery was performed for thrombectomy and tricuspid valve replacement with a tissue valve. DISCUSSION AND CONCLUSION: Detection of TVT in COVID-19 patients on the basis of high index of suspicion, bedside TTE and noninvasive CMR helps early surgical treatment and subsequent reduction of mortality and hospital stay.


Asunto(s)
COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Trombosis , Insuficiencia de la Válvula Tricúspide , Adulto , COVID-19/complicaciones , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía
10.
Kyobu Geka ; 75(5): 392-395, 2022 May.
Artículo en Japonés | MEDLINE | ID: mdl-35474206

RESUMEN

Tricuspid pouch forms during the spontaneous closure of a ventricular septal defect (VSD). Cases have been reported in which the tricuspid pouch was discovered for the first time during surgery and could not be distinguished from an aneurysm of the membranous septum( AMS). A 58-year-old woman had a heart murmur. Transthoracic echocardiography showed an aneurysm-like pouch protruding into the right ventricle. Magnetic resonance imaging could not distinguish between AMS and tricuspid pouch;however, contrast-enhanced computed tomography showed a VSD. The membranous structure comprised multiple lobules, and the tendon of the papillary muscles was continuous with the tricuspid valve. Intraoperatively, the tricuspid valve septal leaflet was adhered to the defect hole. It was incised along the annulus, the VSD was closed with a bovine pericardial patch, and the annulus of the tricuspid valve septal leaflet was suture closed. The patient was discharged after a good postoperative course.


Asunto(s)
Insuficiencia Cardíaca , Defectos del Tabique Interventricular , Animales , Bovinos , Ecocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Defectos del Tabique Interventricular/cirugía , Ventrículos Cardíacos , Humanos , Persona de Mediana Edad , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/cirugía
11.
Kyobu Geka ; 75(2): 92-97, 2022 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-35249083

RESUMEN

A 67-year-old woman presented with dyspnea on effort and cyanosis due to massive tricuspid regurgitation and an atrial septal defect with right to left shunt. She was diagnosed with Ebstein disease at the age of 53 when she underwent surgery for varicose veins. Echocardiography showed the severe apical displacement of the septal and posterior leaflet. The anterior leaflet also partially displaced to the apex and demonstrated tethering caused by a dilated right ventricle. Cardiac magnetic resonance imaging showed a dilated right atrium and an enlarged atrialized right ventricle, in addition to marked low cardiac output in the dilated right ventricle. The surgical findings corresponded to Carpentier classification type C. Cone reconstruction was performed. Bidirectional Glenn anastomosis was reguired because of low cardiac output in the remaining functional right ventricle after Cone reconstruction. The patient's postoperative course was uneventful, and tricuspid regurgitation and stenosis remained mild. The patients had no occurrence of right heart failure or arrhythmia for two years after surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Anomalía de Ebstein , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Anomalía de Ebstein/complicaciones , Anomalía de Ebstein/diagnóstico por imagen , Anomalía de Ebstein/cirugía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/cirugía
12.
N Engl J Med ; 386(4): 327-339, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-34767705

RESUMEN

BACKGROUND: Tricuspid regurgitation is common in patients with severe degenerative mitral regurgitation. However, the evidence base is insufficient to inform a decision about whether to perform tricuspid-valve repair during mitral-valve surgery in patients who have moderate tricuspid regurgitation or less-than-moderate regurgitation with annular dilatation. METHODS: We randomly assigned 401 patients who were undergoing mitral-valve surgery for degenerative mitral regurgitation to receive a procedure with or without tricuspid annuloplasty (TA). The primary 2-year end point was a composite of reoperation for tricuspid regurgitation, progression of tricuspid regurgitation by two grades from baseline or the presence of severe tricuspid regurgitation, or death. RESULTS: Patients who underwent mitral-valve surgery plus TA had fewer primary-end-point events than those who underwent mitral-valve surgery alone (3.9% vs. 10.2%) (relative risk, 0.37; 95% confidence interval [CI], 0.16 to 0.86; P = 0.02). Two-year mortality was 3.2% in the surgery-plus-TA group and 4.5% in the surgery-alone group (relative risk, 0.69; 95% CI, 0.25 to 1.88). The 2-year prevalence of progression of tricuspid regurgitation was lower in the surgery-plus-TA group than in the surgery-alone group (0.6% vs. 6.1%; relative risk, 0.09; 95% CI, 0.01 to 0.69). The frequencies of major adverse cardiac and cerebrovascular events, functional status, and quality of life were similar in the two groups at 2 years, although the incidence of permanent pacemaker implantation was higher in the surgery-plus-TA group than in the surgery-alone group (14.1% vs. 2.5%; rate ratio, 5.75; 95% CI, 2.27 to 14.60). CONCLUSIONS: Among patients undergoing mitral-valve surgery, those who also received TA had a lower incidence of a primary-end-point event than those who underwent mitral-valve surgery alone at 2 years, a reduction that was driven by less frequent progression to severe tricuspid regurgitation. Tricuspid repair resulted in more frequent permanent pacemaker implantation. Whether reduced progression of tricuspid regurgitation results in long-term clinical benefit can be determined only with longer follow-up. (Funded by the National Heart, Lung, and Blood Institute and the German Center for Cardiovascular Research; ClinicalTrials.gov number, NCT02675244.).


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Progresión de la Enfermedad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Dilatación Patológica , Femenino , Estudios de Seguimiento , Humanos , Análisis de Intención de Tratar , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Marcapaso Artificial , Complicaciones Posoperatorias , Calidad de Vida , Reoperación , Análisis de Supervivencia , Válvula Tricúspide/patología , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/terapia
13.
Exp Cell Res ; 411(1): 112972, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34914964

RESUMEN

Calcification of the bicuspid aortic valve (BAV) involves differential expression of various RNA genes, which is achieved through complex regulatory networks that are controlled in part by transcription factors and microRNAs. We previously found that miR-195-5p regulates the osteogenic differentiation of valvular interstitial cells (VICs) by targeting the TGF-ß pathway. However, the transcriptional regulation of miR-195-5p in calcified BAV patients is not yet clear. In this study, stenotic aortic valve tissues from patients with BAVs and tricuspid aortic valves (TAVs) were collected. Candidate transcription factors of miR-195-5p were predicted by bioinformatics analysis and tested in diseased valves and in male porcine VICs. SP2 gene expression and the corresponding protein levels in BAV were significantly lower than those in TAV, and a low SP2 expression level environment in VICs resulted in remarkable increases in RNA expression levels of RUNX2, BMP2, collagen 1, MMP2, and MMP9 and the corresponding proteins. ChIP assays revealed that SP2 directly bound to the transcription promoter region of miR-195-5p. Cotransfection of SP2 shRNA and a miR-195-5p mimic in porcine VICs demonstrated that SP2 repressed SMAD7 expression via miR-195-5p, while knockdown of SP2 increased the mRNA expression of SMAD7 and the corresponding protein and attenuated Smad 2/3 expression. Immunofluorescence staining of diseased valves confirmed that the functional proteins of osteogenesis differentiation, including RUNX2, BMP2, collagen 1, and osteocalcin, were overexpressed in BAVs. In Conclusion, the transcription factor Sp2 is expressed at low levels in VICs from BAV patients, which has a negative impact on miR-195-5p expression by binding its promoter region and partially promotes calcification through a SMAD-dependent pathway.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide/patología , Calcinosis/patología , Osteoblastos/patología , Proteína smad7/metabolismo , Factor de Transcripción Sp2/metabolismo , Factor de Crecimiento Transformador beta1/metabolismo , Válvula Tricúspide/patología , Animales , Enfermedad de la Válvula Aórtica Bicúspide/genética , Enfermedad de la Válvula Aórtica Bicúspide/metabolismo , Proteína Morfogenética Ósea 2/genética , Proteína Morfogenética Ósea 2/metabolismo , Calcinosis/genética , Calcinosis/metabolismo , Diferenciación Celular , Subunidad alfa 1 del Factor de Unión al Sitio Principal/genética , Subunidad alfa 1 del Factor de Unión al Sitio Principal/metabolismo , Femenino , Humanos , Masculino , MicroARNs , Persona de Mediana Edad , Osteoblastos/metabolismo , Osteogénesis , Proteína smad7/genética , Factor de Transcripción Sp2/genética , Porcinos , Factor de Crecimiento Transformador beta1/genética , Válvula Tricúspide/metabolismo
14.
Medicina (Kaunas) ; 59(1)2022 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-36676681

RESUMEN

Background and Objectives: The aim of this study was to clarify the tricuspid valve (TV) and right ventricular (RV) geometry and function characteristics using 3D echocardiography-based analysis and to identify echocardiographic predictors for severe tricuspid regurgitation (TR) in different etiologies of functional TR (fTR). Methods and Results: The prospective study included 128 patients (median age 64 years, 57% females): 109 patients with moderate or severe fTR (69-caused by dominant left-sided valvular pathology (LSVP), 40 due to precapillary pulmonary hypertension (PH)), and 19 healthy controls. The 2D and 3D-transthoracic echocardiography analysis included TV, right atrium, RV geometry, and functional parameters. All the RV geometry parameters as well as 3D TV parameters were increased in both fTR groups when compared to controls. Higher RV diameters, length, areas, volumes, and more impaired RV function were in PH group compared to LSVP group. PH was associated with larger leaflet tenting height, volume, and more increased indices of septal-lateral and major axis tricuspid annulus (TA) diameters. LVSP etiology was associated with higher anterior-posterior TA diameter and sphericity index. Univariate and multivariate logistic regression and ROC analyses revealed that different fTR etiologies were associated with various 2D and 3D echocardiographic parameters to predict severe TR: major axis TA diameter and TA perimeter, the leaflet tenting volume had the highest predictive value in PH group, septal-lateral systolic TA diameter-in LSVP group. The 3D TA analysis provided more reliable prediction for severe fTR. Conclusions: TV and RV geometry vary in different etiologies of functional TR. Precapillary PH is related to more severe RV remodeling and dysfunction and changes of TV geometry, when compared to LSVP group. The 3D echocardiography helps to determine echocardiographic predictors of severe TR in different fTR etiologies.


Asunto(s)
Ecocardiografía Tridimensional , Hipertensión Pulmonar , Insuficiencia de la Válvula Tricúspide , Femenino , Humanos , Persona de Mediana Edad , Masculino , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/patología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estudios Prospectivos , Ecocardiografía , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/diagnóstico por imagen
15.
Heart Rhythm ; 18(12): 2101-2109, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34461305

RESUMEN

BACKGROUND: Leadless pacemakers (LPs) have proven safe and effective, but device revisions remain necessary. Either replacing the LP or implanting a new adjacent LP is feasible. Replacement seems more appealing, but encapsulation and tissue adhesions may hamper the safety and efficacy of LP retrieval. OBJECTIVE: We determined the incidence and cellular characteristics of tissue adherent to retrieved LPs and the potential implications for end-of-life strategy. METHODS: All 15 consecutive successful Nanostim LP retrievals in a tertiary center were included. We assessed the histopathology of adherent tissue and obtained clinical characteristics. RESULTS: Adherent tissue was present in 14 of 15 retrievals (93%; median implantation duration 36 months; range 0-96 months). The tissue consisted of fibrosis (n = 2), fibrosis and thrombus (n = 9), or thrombus only (n = 3). In short-term retrievals (<1 year), mostly fresh thrombi without fibrosis were seen. In later retrievals, the tissue consisted of fibrosis often with organizing or lytic thrombi. Fibrosis showed different stages of organization, notably early fibrocellular and later fibrosclerotic tissue. Inflammatory cells were seen (n = 4) without signs of infection. Tricuspid valve material was retrieved in 1 patient after 36 months, resulting in increased tricuspid regurgitation. CONCLUSION: Our results suggest that fibrosis and thrombus adherent to LPs are common and encapsulate the LP as seen in transvenous pacemakers. LPs may adhere to the tricuspid valve or subvalvular apparatus affecting retrieval safety. The end-of-life strategy should be optimized by incorporating risk stratification for excessive fibrotic encapsulation and adhesions.


Asunto(s)
Remoción de Dispositivos/métodos , Efectos Adversos a Largo Plazo/patología , Marcapaso Artificial , Reoperación , Adherencias Tisulares , Válvula Tricúspide , Anciano de 80 o más Años , Bradicardia/terapia , Análisis de Falla de Equipo , Femenino , Técnicas Histológicas , Humanos , Masculino , Evaluación de Resultado en la Atención de Salud , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Reoperación/efectos adversos , Reoperación/instrumentación , Reoperación/métodos , Adherencias Tisulares/etiología , Adherencias Tisulares/patología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/fisiopatología
17.
BMJ Case Rep ; 14(2)2021 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-33574044

RESUMEN

A 75-year-old was treated for prostate adenocarcinoma with brachytherapy in September 2018. A routine follow-up chest radiograph 3 months later revealed a metallic object of the same dimensions as a brachytherapy pellet located in the right ventricle. Further imaging showed the brachtherapy pellet was located in the anterobasal right ventricular endocardium close to the tricuspid valve. Frequent asymptomatic premature ventricular contractions were observed with likely origin from the left ventricular outflow tract, an area remote from the site of the pellet. The patient remains asymptomatic and subsequent imaging shows that the position of the pellet has not changed.


Asunto(s)
Adenocarcinoma/radioterapia , Braquiterapia/efectos adversos , Braquiterapia/instrumentación , Migración de Cuerpo Extraño/patología , Neoplasias de la Próstata/radioterapia , Válvula Tricúspide/patología , Adenocarcinoma/diagnóstico por imagen , Anciano , Braquiterapia/métodos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Electrocardiografía , Humanos , Imagenología Tridimensional , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología
18.
Int Heart J ; 62(1): 57-64, 2021 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-33455981

RESUMEN

Tricuspid valve (TV) surgery is associated with a high risk of postoperative pacemaker requirement. We set out to identify the incidence of atrioventricular block (AVB) after TV surgery and determine whether atrioventricular conduction recovers within time.We investigated pre/intra- and postoperative predictors of AVB in patients who underwent tricuspid valve surgery (not only isolated TV surgery) at our institution between 2004 and 2017. Patients who had pacemakers prior to surgery were excluded.One year after surgery, 5.8% of the surviving cohort had received a pacemaker due to AVB. In the complete follow-up time, 33 out of 505 patients required pacemaker implantation because of AVB. Of the 37 patients who presented to the intensive care unit postoperatively with AVB III, 14 (38%) underwent pacemaker implantation for AVB, and 20 (54%) did not require a pacemaker. AVB III at ICU admission was identified as a predictor of pacemaker implantation (OR: 9.7, CI: 3.8-24.5, P < 0.001). TV endocarditis was also identified as a predictor (OR: 12.4, CI: 3.3-46.3, P < 0.001). Eleven out of 32 patients (34%) with tricuspid endocarditis required a pacemaker for AVB. The mean ventricular pacing burden within the first 5 years after pacemaker implantation was 79%.The issue of AVB after TV surgery is significant. Both the initial rhythm after surgery and etiology of the tricuspid disease can help predict pacemaker requirement. Within the first 5 years after surgery, the ventricular pacing burden remains high without relevant rhythm recovery.


Asunto(s)
Bloqueo Atrioventricular/etiología , Endocarditis/complicaciones , Marcapaso Artificial/estadística & datos numéricos , Válvula Tricúspide/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/cirugía , Supervivencia sin Enfermedad , Endocarditis/cirugía , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Válvula Tricúspide/patología
19.
J Artif Organs ; 24(2): 217-224, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33483881

RESUMEN

PURPOSE: The purpose of this study was to develop a simple and effective percutaneous approach to create tricuspid regurgitation in swine. METHODS: Eleven pigs (71.68 ± 7.70 kg, 3 male) were involved in this study. A grasping forceps was introduced into the right ventricle through a steerable sheath under fluoroscopic guidance and used to disrupt the tricuspid valve apparatus by avulsing leaflet or chordae tendineae repeatedly. Transthoracic echocardiography and right ventricular angiography were used to evaluate the degree of tricuspid regurgitation created. RESULTS: Ten of the 11 pigs (90.91%) achieved severe tricuspid regurgitation and 1 (9.09%) obtained moderate tricuspid regurgitation immediately after the procedure. Heart rate of the pigs significantly increased immediately after tricuspid regurgitation creation compared to baseline (88.64 ± 23.24 vs. 76.00 ± 15.30 bpm, P = 0.02), but recovered to normal level at one month follow-up (77.09 ± 11.97 bpm, P = 0.85). The right atrium, tricuspid valve annulus, and right ventricle dilated obviously one month after tricuspid regurgitation creation (dimension changes: 3.01 ± 0.35 vs. 3.56 ± 0.40 cm, P = 0.02; 2.92 ± 0.36 vs. 3.37 ± 0.39 cm, P = 0.01; 3.06 ± 0.42 vs. 3.60 ± 0.47 cm, P = 0.03 respectively). Autopsy findings showed that rupture of leaflet and/or chordae tendineae finally led to the tricuspid regurgitation. CONCLUSIONS: Severe tricuspid regurgitation can be created by a simple and effective percutaneous approach with a grasping forceps in swine model and right heart dilation can be observed consistently at one-month follow-up. This model will be valuable in pre-clinical studies for developing new tricuspid valve repair or replacement technique to treat severe tricuspid regurgitation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Modelos Animales de Enfermedad , Porcinos , Insuficiencia de la Válvula Tricúspide/patología , Animales , Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/patología , Cuerdas Tendinosas/fisiopatología , Ecocardiografía , Procedimientos Endovasculares/métodos , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/fisiopatología
20.
J Thorac Cardiovasc Surg ; 161(2): e191-e207, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31733883

RESUMEN

BACKGROUND: Surgical repair of functional tricuspid regurgitation is centered on annular reduction with artificial rings; however, the precise effect of prosthesis implantation on annular geometry, dynamics, and strain is unknown. METHODS: Forty healthy sheep had sonomicrometry crystals implanted around the tricuspid annulus and onto right ventricle free wall. Ten animals underwent tricuspid annuloplasty with a flexible Duran AnCore ring (Medtronic, Minneapolis, Minn) (28 ± 1 mm), 10 with Contour 3D rigid ring (Medtronic) (29 ± 1 mm), 10 with hybrid Tri-Ad Adams band (Medtronic) (28 ± 1 mm), and 10 had no prosthesis (control group). Pressure sensors were inserted in the left ventricle, right ventricle, and right atrium. Data were acquired with open chest after weaning off cardiopulmonary bypass and hemodynamic stabilization. Annular area, global and regional contraction, height, and strain were calculated based on cubic spline fits to crystal locations. RESULTS: Tricuspid annular area contraction during the cardiac cycle was 11% ± 3% in the control group. The Contour 3D ring significantly impaired annular contraction (2% ± 1%) whereas the Duran AnCore ring and Tri-Ad Adams band (9% ± 3% and 8% ± 4%, respectively) permitted dynamic area change. Global perimeter reduction was 6% ± 1% in the control group and decreased in the Duran AnCore (3% ± 1%), Contour 3D (0.4% ± 0.2%), and Tri-Ad Adams (3% ± 1%) groups (all P values < .001 vs control). Annular height was 6.2 ± 2.0 mm in the control group, unchanged in the Contour 3D (4.9 ± 1.1 mm) but reduced in the Duran AnCore (3.1 ± 1.3 mm) and Tri-Ad Adams (3.1 ± 1.0 mm) groups (P < .001 Duran AnCore and Tri-Ad Adams vs control). Rings perturbed systolic global annular strain (control, 5.3% ± 1.8%; Duran AnCore, 2.3% ± 1.0%; Contour 3D, 0.6% ± 0.2%; and Tri-Ad Adams, -2.6% ± 0.7%) with Contour 3D inducing the biggest change (P < .05 vs other groups). CONCLUSIONS: In healthy ovine hearts, flexible and hybrid rings better preserved annular dynamics and strain, whereas the rigid ring maintained 3-dimensional geometry. These data may aid the design of optimal tricuspid annular prostheses and improve durability of valve repair.


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Válvula Tricúspide/cirugía , Animales , Anuloplastia de la Válvula Cardíaca/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Masculino , Ovinos , Válvula Tricúspide/patología , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...