Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-38912744

RESUMEN

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Asunto(s)
Stents Liberadores de Fármacos , Humanos , Italia , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/cirugía
4.
JACC Asia ; 3(4): 686, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37614536
6.
Front Cardiovasc Med ; 9: 1051174, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36531736

RESUMEN

Background: In ST-elevation myocardial infarction (STEMI) patients undergoing primary percutaneous coronary angioplasty (PPCI) the index of microcirculatory resistance (IMR) correlates to the extent of myocardial damage and left ventricular (LV) function recovery. Data on the IMR time-course and impact on clinical outcome in STEMI patients with multi-vessel disease (MVD) are scarce. Aims: We designed a prospective, multicenter clinical trial to assess the infarct-related artery (IRA)-IMR in STEMI patients with MVD undergoing PPCI and to explore its potential in relationship with outcome and LV remodeling. Methods: The study enrolled 242 STEMI patients with MVD. Both fractional flow reserve (FFR) and IMR of the IRA were assessed after successful PPCI. Then, FFR/IMR measurements were repeated in the IRA at a staged angiography, and FFR-guided angioplasty was performed in non-IRA lesions. The primary endpoint was the composite of cardiovascular death, re-infarction, re-hospitalization for heart failure, resuscitation or appropriate ICD shock at 1-year follow-up. Results: A significant improvement of IRA-IMR values (from 47.9 to 34.2, p < 0.0001) was observed early after PPCI. Staged FFR-guided angioplasty was performed in 102 non-IRA lesions. We failed to find a correlation between IRA-IMR, clinical events and LV remodeling. Notwithstanding, in patients with anterior STEMI an inverse correlation between initial IMR values and LV function at follow-up was observed. Conclusion: After successful PPCI, a significant proportion of patients with STEMI and MVD had coronary microvascular dysfunction as assessed by IMR that recovered early after reperfusion. Higher IMR values predicted lack of improvement of LV function only in anterior STEMI. Clinical trial registration: https://clinicaltrials.gov/, identifier [NCT02325973].

9.
Eur Heart J Case Rep ; 5(10): ytab385, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34738061

RESUMEN

BACKGROUND: The optimal treatment of aneurysmal or ectatic culprit vessels in the setting of acute myocardial infarction is still matter of debate, as revascularization with either percutaneous intervention or surgery is associated with low procedural success and poor outcomes. CASE SUMMARY: We report the case of a 55-year-old male patient, admitted for inferior ST-elevation myocardial infarction, who underwent successful percutaneous implantation of a micro-mesh self-expanding nitinol carotid stent in a right coronary aneurysm with intravascular ultrasonography measured diameter of 9 mm and massive thrombus apposition. DISCUSSION: The technical characteristics of the micro-mesh self-expanding nitinol carotid stent allow for adequate plaque coverage and good apposition even in large vessels, making this device particularly suitable for the treatment of coronary lesions with high thrombus burden, when severe coronary ectasia or aneurysms are present.

10.
Cardiovasc Revasc Med ; 28S: 68-71, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33840619

RESUMEN

In 2020, the coronavirus disease 2019 (COVID-19) pandemic has led to a decrease in interventional treatment for structural heart disease worldwide. In this context, the management of patients with symptomatic severe aortic stenosis (AS) or bioprosthetic valve dysfunction (BVD) represents a clinical challenge, as a delay in aortic valve replacement procedures may increase short-term morbidity and mortality. We report four cases of TAVR performed in patients with Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection. All of them were discharged in good clinical conditions and no adverse events were reported at 30 days follow-up. Our experience suggests that in selected patients with mild SARS-CoV-2 infection and symptomatic native AS or BVD, TAVR has a favorable short-term outcome.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Humanos , Factores de Riesgo , SARS-CoV-2 , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
Eur Heart J Case Rep ; 4(3): 1-5, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32617468

RESUMEN

BACKGROUND: Iatrogenic membranous ventricular septal defects (VSDs) are rare complications of cardiothoracic surgery, such as septal myectomy for hypertrophic obstructive cardiomyopathy (HOCM). Transcatheter closure is considered an appealing alternative to surgery, given the increased mortality associated with repeated surgical procedures, but reports are extremely limited. CASE SUMMARY: We herein report the case of a 63-year-old woman with HOCM who underwent successful percutaneous closure of an iatrogenic VSD after septal myectomy. Two percutaneous techniques are discussed, namely the 'muscular anchoring' and the 'buddy wire delivery', aimed at increasing support and providing stability to the system during percutaneous intervention. DISCUSSION: Transcatheter closure represents an attractive minimally invasive approach for the management of symptomatic iatrogenic VSDs. The new techniques described could help operators to cross tortuous and tunnelled defects and to deploy closure devices in case of complex VSD anatomy.

12.
Catheter Cardiovasc Interv ; 95(5): 993-1000, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31099970

RESUMEN

BACKGROUND: Peripheral arterial disease (PAD) plays a decisive role in the preinterventional selection process of the optimal vascular access site in patients undergoing transcatheter aortic valve implantation (TAVI). However, the impact of PAD on mortality and vascular complications (VCs) in TAVI-treated patients remains unclear. Accordingly, we aimed to assess the outcomes of patients with and without PAD undergoing TAVI, by performing a meta-regression analysis. METHODS: Studies published between January 2002 and March 2018 and reporting outcomes according to the presence of PAD in TAVI patients were identified. Outcome measures analyzed were short-, mid- and long-term mortality, and peri-procedural VC. The interaction between sheath size and PAD on outcomes was also assessed. RESULTS: A total of 26 studies (68,581 TAVI patients, of whom 17,326 with preprocedural PAD) were included in the analysis. Patients with PAD had higher risk of mortality at short- (HR 1.36, 95% confidence interval [CI] 1.13-1.63, p = .0009), mid- (HR 1.18, 95% CI 1.08-1.30, p = .0005), and long-term (HR 1.36, 95% CI 1.24-1.48, p < .0001) follow-up, and higher risk of VC (RR 1.55, 95% CI 1.27; 1.89, p < .0001). Moreover, the adoption of smaller sheaths during TAVI procedures was associated with fewer VC both in PAD and non-PAD patients, but the latter group had a more pronounced benefit. CONCLUSIONS: Patients with pre-existent PAD are at increased risk of all-cause mortality and VC after TAVI. The adoption of smaller sheaths during the procedure seems to be associated with fewer peri-procedural VC both in PAD and non-PAD patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Enfermedad Arterial Periférica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Hemodinámica , Humanos , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/mortalidad , Complicaciones Posoperatorias/epidemiología , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
Int J Cardiol ; 298: 76-82, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31575495

RESUMEN

BACKGROUND: Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve replacement (TAVR) randomized trials. METHODS: With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker implantation, vascular complications and 1-year mortality. RESULTS: Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR = 1.13; 95% CI 0.88-1.46, p = 0.33) and 1-year mortality (OR = 1.02; 95% CI 0.77-1.37, p = 0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR = 2.35; 95% CI 1.30-4.23, p = 0.005), implantation of a second valve (OR = 2.06; 95% CI 1.31-3.25; p = 0.002), moderate/severe paravalvular leakage (PVL) (OR = 1.67; 95% CI 1.29-2.17; p = 0.0001) and device failure (OR = 1.26; 95% CI 1.02-1.56; p = 0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture. CONCLUSIONS: BAV patients treated with TAVR had similar 30-day and 1-year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conversion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Bioprótesis/tendencias , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Estudios Observacionales como Asunto/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
15.
Circ Cardiovasc Interv ; 11(6): e006247, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29903715

RESUMEN

BACKGROUND: Invasive physiological assessment of myocardial bridges (MBs) is largely unsettled. Unlike fractional flow reserve (FFR), instantaneous wave-free ratio (iFR) is a diastole-specific index. As such, its value might not be hampered by systolic pressure overshooting and negative systolic pressure gradient caused by the compression of the tunneled coronary artery. METHODS AND RESULTS: We prospectively enrolled 20 patients with angina and/or positive noninvasive stress test, absence of significant coronary artery stenosis, and angiographic suspicion/evidence of MB in the left anterior descending artery. According to a prespecified protocol, all patients underwent functional intracoronary evaluation with FFR at rest and after dobutamine (up to 20 µg kg-1 min-1) and atropine (1 mg) intravenous infusion. iFR at baseline and dobutamine-induced hyperemic wave-free period pressure ratio were also recorded. FFR values ≤0.80 and iFR values ≤0.89 were considered indicative of hemodynamic significance of MB. At baseline, no MB was hemodynamically significant according to FFR, whereas iFR was below the cutoff value in all but 7 patients. During inotropic challenge, median FFR did not change significantly (0.87-0.86, P=0.59). CONCLUSIONS: Physiological evaluation of MBs with iFR seems to be more consistent with patients' symptoms and noninvasive test results compared with FFR.


Asunto(s)
Cateterismo Cardíaco , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Puente Miocárdico/diagnóstico , Adenosina/administración & dosificación , Anciano , Atropina/administración & dosificación , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Dobutamina/administración & dosificación , Femenino , Humanos , Hiperemia/fisiopatología , Masculino , Persona de Mediana Edad , Puente Miocárdico/fisiopatología , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada de Emisión de Fotón Único
16.
Catheter Cardiovasc Interv ; 92(2): E115-E124, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29513403

RESUMEN

BACKGROUND: Patients with small vessel disease (SVD) are at higher risk of adverse events after PCI compared to non-SVD patients. In this subset, the use of bioresorbable vascular scaffolds (BVS) has raised particular concern. OBJECTIVE: We aimed to compare outcomes of Absorb BVS versus a 2nd-generation metallic everolimus-eluting stents (EES) in the SVD setting, by pooling patients from three large, prospective studies. METHODS: Patients with SVD (reference vessel diameter ≤2.75 mm by QCA) and treated with Absorb BVS were identified in the Italian RAI and the MAASSTAD-Absorb registries. EES controls were identified in the COMPARE II Trial. We performed a propensity-score matching using several clinical and angiographic variables. Implantation technique was not object of matching, being device-specific. RESULTS: Out of 4635 enrolled subjects, 1147 belonged to the SVD population. After matching, we obtained 337 pairs of patients. High clinical and angiographic complexity was found in both groups. Predilation and postdilation rates were significantly higher in BVS patients. No differences were found in terms of the device-oriented composite end-point at 1-year (HR = 1.08, 95%CI 0.5-2.3, P = .8) and 2-years (HR = 1.28, 95% CI: 0.68-2.43, P = .5). Notwithstanding, higher incidence of definite/probable stent thrombosis was observed in the BVS group at 1 year (HR 4.7, 95%CI 0.8-31.4, P = .08) and 2-years (HR = 8.34 95%CI 1.1-60.2, P = .04). CONCLUSION: In this propensity-matched analysis pooling SVD patients of three large prospective studies, incidence of composite device-related events was comparable between BVS and EES up to 2 years follow-up. However, higher rates of stent thrombosis were found in the BVS group.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Metales , Intervención Coronaria Percutánea/instrumentación , Anciano , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Trombosis Coronaria/epidemiología , Everolimus/efectos adversos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Puntaje de Propensión , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
G Ital Cardiol (Rome) ; 18(12): 871-874, 2017 Dec.
Artículo en Italiano | MEDLINE | ID: mdl-29189831

RESUMEN

Newer generation of self-expandable nitinol coronary stents has proven to be useful in the treatment of bifurcations, tapered vessels, thrombotic lesions, venous grafts and ectatic segments. However, optimal device positioning can be cumbersome, due to the peculiar delivery mechanism which consists of retracting an outer sheath in order to release the stent from the distal edge. We report the case of a 53-year-old man, admitted for unstable angina. Coronary angiography showed a tight stenosis of the proximal left anterior descending coronary artery. As the lesion was located in an ectatic segment of the vessel, we chose to implant a StentysTM (Stentys S.A., Paris, France) device. During the release, the stent jumped forward, resulting in geographic miss. We describe the technique used to retrieve the stent and how we re-deployed it in the proper position; moreover, we examine the lesion characteristics which fostered the migration of the self-apposing stent along the vessel.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Metálicos Autoexpandibles , Remoción de Dispositivos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Retratamiento
18.
Am Heart J ; 192: 64-75, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28938965

RESUMEN

BACKGROUND: Conflicting data have been reported related to the impact of atrial fibrillation (AF) on the outcomes after transcatheter aortic valve implantation (TAVI). We aimed to assess the prognosis of TAVI-treated patients according to the presence of pre-existing or new-onset AF. METHODS: Studies published between April 2002 and November 2016 and reporting outcomes of pre-existing AF, new-onset AF, or sinus rhythm in patients undergoing TAVI were identified with an electronic search. Pairwise and network meta-analysis were performed. Outcomes of interest were short- and long-term mortality, stroke, and major bleeding. RESULTS: Eleven studies (11,033 individuals) were eligible. Compared to sinus rhythm, short-term and long-term mortality were significantly higher in new-onset AF (short-term OR 2.9, P=.002; long-term OR 2.3, P<.0001) and pre-existing AF groups (short-term OR 2.7, P=.004; long-term OR 2.8, P<.0001). Compared to sinus rhythm, new-onset AF increased the risk of stroke at early (OR 2.1, P<.0001) and late follow-up (OR 1.92, P<.0001), and the risk of early bleedings (OR 1.65, P=.002), while pre-existing AF increased the risk of late stroke (OR 1.3, P=0.03), but not the risk of bleeding. Compared to pre-existing AF, new-onset AF correlated with higher risk of early stroke (OR 1.7, P=.002) and major bleedings (OR 1.7, P=.002). CONCLUSIONS: AF is associated with impaired outcomes after TAVI, including mortality, stroke and (limited to new-onset AF) major bleedings. Compared to pre-existing AF, new-onset AF correlates with higher risk of early stroke and major bleedings. Improved management of AF in the TAVI setting, including tailored antithrombotic treatment strategies, remains a relevant need.


Asunto(s)
Fibrilación Atrial/complicaciones , Frecuencia Cardíaca/fisiología , Accidente Cerebrovascular/epidemiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Electrocardiografía , Salud Global , Humanos , Incidencia , Pronóstico , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter
20.
Int J Cardiol ; 224: 107-111, 2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-27643474

RESUMEN

BACKGROUND: Post-procedure non-access site-related bleedings have a significant impact on mortality in patients treated by transcatheter aortic valve replacement (TAVR). Notwithstanding, the source of these bleedings is frequently indeterminate, with potentially serious clinical implications related to lack of diagnosis and treatment. METHODS: Out of 513 TAVR performed between June 2007 and January 2016 in the Interventional Cardiology Laboratory of the Department of Cardiac, Thoracic and Vascular Sciences, University Hospital of Padua, we identified few proven cases of concealed bleeding after TAVR due to blood oozing. RESULTS: We report three cases of angiographically confirmed post-TAVR non-access bleedings related to spontaneous blood oozing, a life-threatening condition consisting of diffuse capillary hemorrhage developing from vessels not directly involved by the procedure. We hypothesize that spontaneous post-procedural blood oozing may account for a substantial proportion of non-overt, non-access site-related bleeding after TAVR. CONCLUSION: The possibility of post-TAVR blood oozing is largely neglected in the literature, and comprehensive categorization of non-access site bleedings in current standardized endpoints of TAVR studies is missing. Early assessment with arterial and venous contrast phase angio-MDCT scans in case of post-TAVR unexplained and persistent anemia may allow diagnosis and treatment of this subtle condition.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Capilares , Embolización Terapéutica/métodos , Hemorragia Posoperatoria , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Capilares/diagnóstico por imagen , Capilares/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Femenino , Heparina/administración & dosificación , Heparina/efectos adversos , Humanos , Atención Perioperativa/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/efectos adversos , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/fisiopatología , Espacio Retroperitoneal/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...