Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
2.
Europace ; 25(4): 1423-1431, 2023 04 15.
Article En | MEDLINE | ID: mdl-36794691

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Case-Control Studies , Death, Sudden, Cardiac/etiology , Retrospective Studies , Treatment Outcome
3.
JMIR Cardio ; 6(1): e30661, 2022 Apr 19.
Article En | MEDLINE | ID: mdl-35103602

BACKGROUND: The COVID-19 pandemic forced several European governments to impose severe lockdown measures. The reduction of physical activity during the lockdown could have been deleterious. OBJECTIVE: The aim of this observational, retrospective study was to investigate the effect of the lockdown strategy on the physical activity burden and subsequent reassessment in a group of patients with heart failure who were followed by means of remote monitoring. METHODS: We analyzed remote monitoring transmissions during the 3-month period immediately preceding the lockdown, 69 days of lockdown, and 3-month period after the first lockdown in a cohort of patients with heart failure from a general hospital in Lombardy, Italy. We compared variation of daily physical activity measured by cardiac implantable electrical devices with clinical variables collected in a hospital database. RESULTS: We enrolled 41 patients with heart failure that sent 176 transmissions. Physical activity decreased during the lockdown period (mean 3.4, SD 1.9 vs mean 2.9, SD 1.8 hours/day; P<.001) but no significant difference was found when comparing the period preceding and following the lockdown (-0.0007 hours/day; P=.99). We found a significant correlation between physical activity reduction during and after the lockdown (R2=0.45, P<.001). The only significant predictor of exercise variation in the postlockdown period was the lockdown to prelockdown physical activity ratio. CONCLUSIONS: An excessive reduction of exercise in patients with heart failure decreased the tolerance to exercise, especially in patients with more comorbidities. Remote monitoring demonstrated exercise reduction, suggesting its potential utility to encourage patients to maintain their usual physical activity levels.

4.
Arrhythm Electrophysiol Rev ; 10(2): 68-76, 2021 Jul.
Article En | MEDLINE | ID: mdl-34401178

Thromboembolism is the most serious complication of AF, and oral anticoagulation is the mainstay therapy. Current guidelines place all AF types together in terms of anticoagulation with the major determinants being associated comorbidities translated into risk marker. Among patients in large clinical trials, those with non-paroxysmal AF appear to be at higher risk of stroke than those with paroxysmal AF. Higher complexity of the AF pattern is also associated with higher risk of mortality. Moreover, continuous monitoring of AF through cardiac implantable devices provided us with the concept of 'AF burden'. Usually, the larger the AF burden, the higher the risk of stroke; however, the relationship is not well characterised with respect to the threshold value above which the risk increases. The picture is more complex than it appears: AF and underlying disorders must act synergically respecting the magnitude of its own characteristics, which are the amount of time a patient stays in AF and the severity of associated comorbidities.

...