Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiothorac Surg ; 19(1): 339, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38902781

RESUMEN

BACKGROUND: Acute Stanford type- A aortic dissections make up a large part of emergency cardiac surgery. They also carry a significant burden of morbidity. New techniques to aid aortic remodelling include the Ascyrus Medical Dissection Stent (AMDS): Its increasing use, looks to present a potential problem in cases where surgery involving the aortic arch may be required. CASE REPORT: We present the case of a 49-year-old male who underwent urgent redo-surgery for total arch replacement and de-branching following recent replacement of the ascending aorta for acute type-A dissection, where an AMDS stent was deployed. The patient underwent total arch replacement with a stented tri-furcate prosthesis and de-branching of arch vessels with the stent landed inside the previous AMDS, to good effect. CONCLUSION: This case highlights a possible approach to aortic arch surgery in patients who have previous had AMDS insertion.


Asunto(s)
Aorta Torácica , Aneurisma de la Aorta Torácica , Disección Aórtica , Hematoma , Stents , Humanos , Masculino , Persona de Mediana Edad , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Hematoma/cirugía , Hematoma/etiología , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Reoperación , Prótesis Vascular
2.
J Magn Reson Imaging ; 55(5): 1301-1321, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34416048

RESUMEN

Four-dimensional (4D) flow magnetic resonance imaging (MRI) allows multidirectional quantification of blood flow in the heart and great vessels. Comparability of the technique to the current reference standards of flow assessment-two-dimensional (2D) flow MRI and Doppler echocardiography-varies in the literature. Image acquisition parameters likely impact upon the accuracy and reproducibility of 4D flow MRI. We therefore sought to review the current literature on 4D flow MRI in the heart and great vessels, in comparison to 2D flow MRI, Doppler echocardiography, and invasive catheterization. Using a predefined search strategy and inclusion and exclusion criteria, the databases EMBASE and Medline were searched in January 2021 for peer-reviewed research articles comparing cardiac 4D flow MRI to 2D flow MRI, Doppler echocardiography and/or invasive catheterization. The data from all relevant articles were assimilated and analyzed using Mann-Whitney U and chi χ2 test. Forty-four manuscripts met the eligibility criteria and were included in the review. The review showed agreement of 4D flow MRI to the reference standard methods of flow assessment, particular in the measurement of peak velocity and stroke volume in 55% of manuscripts. The use of valve tracking significantly improves agreement between 4D flow MRI and the reference modalities (79% matching with the use of valve tracking vs. 50% without, P = 0.04). This review highlights that the impact of acquisition parameters on 4D flow MRI accuracy is multifactorial. It is therefore important that each center conducts its own quality assurance prior to using 4D flow MRI for clinical decision-making. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Velocidad del Flujo Sanguíneo/fisiología , Corazón/diagnóstico por imagen , Hemodinámica , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA