Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 62
1.
Article En | MEDLINE | ID: mdl-38814252

BACKGROUND: Catheter ablation (CA) of atrial fibrillation is routinely used to obtain rhythm control. Evidence suggest that catheter ablation should be done during uninterrupted oral anticoagulation. METHODS: Italian Registry in the setting of atrial fibrillation ablation with rivaroxaban (IRIS) is an Italian multicenter, non-interventional, prospective study which enrolled 250 consecutive atrial fibrillation patients eligible for catheter ablation on rivaroxaban. The decision for rivaroxaban management was left to the physician: uninterrupted or shortly interrupted prior to Catheter ablation. Patients received a follow-up visit at 1 month and 12 months after the procedure. RESULTS: The primary outcome, represented by all-cause death and systemic embolism at 1 month and 12 months was characterized by one transient ischemic attack and one myocardial infarction in the first 30 days. Both events happened in patients with shortly interrupted strategy (P=0.147), and both in patients who underwent radiofrequency ablation (P=0.737). In the primary safety outcome represented by major bleeding we did not register any event in the 12-month follow-up. The secondary outcome constituted by minor bleeding registered 1 event, after the first 30 days since CA. CONCLUSIONS: IRIS is the biggest real-life data registry regarding CA ablation on rivaroxaban in Italian setting, proving the safety and efficacy of rivaroxaban.

2.
Article En | MEDLINE | ID: mdl-38814525

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

3.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Article En | MEDLINE | ID: mdl-38519418

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Action Potentials , Atrial Fibrillation , Catheter Ablation , Heart Rate , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Middle Aged , Catheter Ablation/adverse effects , Aged , Prospective Studies , Time Factors , Italy , Risk Factors , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Progression-Free Survival
5.
Article En | MEDLINE | ID: mdl-37985538

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF. PURPOSE: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter. METHODS: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures. RESULTS: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 ± 6 min vs 18.5 ± 9 min for time to PVI, p < 0.0001; 38.8 ± 7 vs 32.5 ± 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 ± 19 min vs 71.8 ± 29 min for primary operator time, p = 0.5301; 16.1 ± 8 min vs 18.2 ± 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 ± 26 min vs 91.4 ± 37 min, p = 0.0046). No major procedure-related adverse events were reported. CONCLUSION: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.

6.
J Cardiovasc Electrophysiol ; 34(8): 1764-1767, 2023 08.
Article En | MEDLINE | ID: mdl-37354446

INTRODUCTION: We describe the first case of the use of pulsed-field ablation (PFA) to treat focal atrial tachycardia (FAT) in a pediatric patient. METHODS: An 11-year-old girl with obesity was referred to our center for ablation of incessant atrial tachycardia. The earliest atrial activation was shown to be present in the left superior pulmonary vein. Radiofrequency ablation of FAT seems to be associated with a lower success rate and, especially, with a higher complication rate than in adult patients. RESULTS: We performed ablation by means of a novel nonthermal energy source (PFA) that is able to reduce the risk of complications due to injury to anatomic structures surrounding the heart. After the first application, stable sinus rhythm was restored. CONCLUSIONS: PFA can be used to treat FAT arising from pulmonary veins in young children as a good alternative to RFA ablation, thereby reducing the risk of potential procedure-related complications.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Tachycardia, Ectopic Atrial , Adult , Female , Humans , Child , Child, Preschool , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Heart Atria , Atrial Fibrillation/surgery , Treatment Outcome
7.
Sensors (Basel) ; 23(3)2023 Jan 27.
Article En | MEDLINE | ID: mdl-36772467

Modern cardiac pacemakers are equipped with a function that allows the heart rate to adapt to the current needs of the patient in situations of increased demand related to exercise and stress ("rate-response" function). This function may be based on a variety of mechanisms, such as a built-in accelerometer responding to increased chest movement or algorithms sensing metabolic demand for oxygen, analysis of intrathoracic impedance, and analysis of the heart rhythm (Q-T interval). The latest technologies in the field of rate-response functionality relate to the use of an accelerometer in leadless endocavitary pacemakers; in these devices, the accelerometer enables mapping of the mechanical wave of the heart's work cycle, enabling the pacemaker to correctly sense native impulses and stimulate the ventricles in synchrony with the cycles of atria and heart valves. Another modern system for synchronizing pacing rate with the patient's real-time needs requires a closed-loop system that continuously monitors changes in the dynamics of heart contractions. This article discusses the technical details of various solutions for detecting and responding to situations related to increased oxygen demand (e.g., exercise or stress) in implantable pacemakers, and reviews the results of clinical trials regarding the use of these algorithms.


Pacemaker, Artificial , Humans , Heart Rate/physiology , Heart Atria , Heart Ventricles , Oxygen
8.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Article En | MEDLINE | ID: mdl-35080355

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Atrial Fibrillation , Catheter Ablation , Humans , Rivaroxaban/adverse effects , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Prospective Studies , Factor Xa Inhibitors/adverse effects , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Registries
9.
J Pers Med ; 12(9)2022 Sep 15.
Article En | MEDLINE | ID: mdl-36143297

Background. Cardiac resynchronization therapy (CRT) is a treatment for heart failure (HF) patients with prolonged QRS and impaired left ventricular (LV) systolic function. We aim to evaluate how the baseline PR interval is associated with outcomes (all-cause death or HF hospitalizations) and LV reverse remodeling (>15% relative reduction in LV end-systolic volume). Methods. Among 2224 patients with CRT defibrillators, 1718 (77.2%) had a device programmed at out-of-the-box settings (sensed AV delay: 100 ms and paced AV delay: 130 ms). Results. In this cohort of 1718 patients (78.7% men, mean age 66 years, 71.6% in NYHA class III/IV, LVEF = 27 ± 6%), echocardiographic assessment at 6-month follow-up showed that LV reverse remodeling was not constant as a function of the PR interval; in detail, it occurred in 56.4% of all patients but was more frequent (76.6%) in patients with a PR interval of 160 ms. In a median follow-up of 20 months, the endpoint of death or HF hospitalizations occurred in 304/1718 (17.7%) patients; in the multivariable regression analysis it was significantly less frequent when the PR interval was between 150 and 170 ms (hazard ratio = 0.79, 95% confidence interval (CI): 0.63−0.99, p = 0.046). The same PR range was associated with higher probability of CRT response (odds ratio = 2.51, 95% CI: 1.41−4.47, p = 0.002). Conclusions. In a large population of CRT patients, with fixed AV pacing delays, specific PR intervals are associated with significant benefits in terms of LV reverse remodeling and lower morbidity. These observational data suggest the importance of optimizing pacing programming as a function of the PR interval to maximize CRT response and patient outcome.

10.
J Cardiovasc Med (Hagerstown) ; 21(6): 420-427, 2020 Jun.
Article En | MEDLINE | ID: mdl-32332379

BACKGROUND: Temporary transvenous cardiac pacing (TTCP) is a standard procedure in current practice, despite limited coverage in consensus guidelines. However, many authors reported several complications associated with TTCP, especially development of infections of cardiac implantable electronic devices (CIED). The aim of this survey was to provide a country-wide picture of current practice regarding TTCP. METHODS: Data were collected using an online survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing. RESULTS: We collected data from 102 physicians, working in 81 Italian hospitals from 17/21 regions. Our data evidenced that different strategies are adopted in case of acute bradycardia with a tendency to limit TTCP mainly to advanced atrioventricular block. However, some centers reported a greater use in elective procedures. TTCP is usually performed by electrophysiologists or interventional cardiologists and, differently from previous reports, mainly by a femoral approach and with nonfloating catheters. We found high inhomogeneity regarding prevention of infections and thromboembolic complications and in post-TTCP management, associated with different TTCP volumes and a strategy for management of acute bradyarrhythmias. CONCLUSION: This survey evidenced a high inhomogeneity in the approaches adopted by Italian cardiologists for TTCP. Further studies are needed to explore if these divergences are associated with different long-term outcomes, especially incidence of CIED-related infections.


Bradycardia/therapy , Cardiac Electrophysiology/trends , Cardiac Pacing, Artificial/trends , Cardiologists/trends , Electrophysiologic Techniques, Cardiac/trends , Pacemaker, Artificial/trends , Practice Patterns, Physicians'/trends , Bradycardia/diagnosis , Bradycardia/physiopathology , Health Care Surveys , Healthcare Disparities/trends , Humans , Italy
11.
Europace ; 21(12): 1890-1899, 2019 12 01.
Article En | MEDLINE | ID: mdl-31665280

AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men. METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098). CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.


Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable , Device Removal , Intraoperative Complications/epidemiology , Postoperative Complications/epidemiology , Prosthesis-Related Infections/therapy , Aged , Aged, 80 and over , Electric Power Supplies , Europe , Female , Humans , Leukocyte Count , Male , Middle Aged , Odds Ratio , Pacemaker, Artificial , Registries , Sex Factors , Time Factors , Tricuspid Valve Insufficiency/epidemiology , Venous Thrombosis/epidemiology
14.
J Atr Fibrillation ; 8(5): 1365, 2016.
Article En | MEDLINE | ID: mdl-27909481

Cardiac resynchronization therapy (CRT) is an accepted treatment for patients with heart failure (HF), impaired left ventricular (LV) function, and a wide QRS complex. However, more than 30% of eligible patients fail to benefit from CRT. It is clearly necessary to define the characteristics of the best candidates for this therapy. To this end, surface ECG and echocardiography have been tested. Unfortunately, however, neither of these examinations has proved sufficiently able to identify the best patients. A tailored approach based on the evaluation of both electrical and mechanical delay to guide LV lead placement seems to be the most reasonable strategy in order to increase the efficacy of CRT therapy. The good preliminary data that have been published suggest that using intracardiac echocardiography to define the mechanical delay could be an interesting option. Moreover, at present it is the only option available that can enable intraprocedural evaluation of the mechanical activation sequence. Naturally, further randomized studies with larger populations should be performed in order to ascertain the real benefit of this approach and to evaluate whether it will outweigh the additional cost of this technology.

17.
Circulation ; 133(17): 1637-44, 2016 Apr 26.
Article En | MEDLINE | ID: mdl-27029350

BACKGROUND: Whether catheter ablation (CA) is superior to amiodarone (AMIO) for the treatment of persistent atrial fibrillation (AF) in patients with heart failure is unknown. METHODS AND RESULTS: This was an open-label, randomized, parallel-group, multicenter study. Patients with persistent AF, dual-chamber implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator, New York Heart Association II to III, and left ventricular ejection fraction <40% within the past 6 months were randomly assigned (1:1 ratio) to undergo CA for AF (group 1, n=102) or receive AMIO (group 2, n=101). Recurrence of AF was the primary end point. All-cause mortality and unplanned hospitalization were the secondary end points. Patients were followed up for a minimum of 24 months. At the end of follow-up, 71 (70%; 95% confidence interval, 60%-78%) patients in group 1 were recurrence free after an average of 1.4±0.6 procedures in comparison with 34 (34%; 95% confidence interval, 25%-44%) in group 2 (log-rank P<0.001). The success rate of CA in the different centers after a single procedure ranged from 29% to 61%. After adjusting for covariates in the multivariable model, AMIO therapy was found to be significantly more likely to fail (hazard ratio, 2.5; 95% confidence interval, 1.5-4.3; P<0.001) than CA. Over the 2-year follow-up, the unplanned hospitalization rate was (32 [31%] in group 1 and 58 [57%] in group 2; P<0.001), showing 45% relative risk reduction (relative risk, 0.55; 95% confidence interval, 0.39-0.76). A significantly lower mortality was observed in CA (8 [8%] versus AMIO (18 [18%]; P=0.037). CONCLUSIONS: This multicenter randomized study shows that CA of AF is superior to AMIO in achieving freedom from AF at long-term follow-up and reducing unplanned hospitalization and mortality in patients with heart failure and persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00729911.


Amiodarone/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/therapy , Catheter Ablation/methods , Defibrillators, Implantable , Heart Failure/therapy , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Female , Follow-Up Studies , Heart Failure/diagnosis , Heart Failure/epidemiology , Humans , Male , Middle Aged , Treatment Outcome
18.
Heart Rhythm ; 13(1): 132-40, 2016 Jan.
Article En | MEDLINE | ID: mdl-26277862

BACKGROUND: It is unclear whether isolation of the left atrial posterior wall (LAPW) offers additional benefits over pulmonary vein antrum isolation (PVAI) alone in patients with persistent atrial fibrillation (AF). OBJECTIVE: We sought to determine the impact of PVAI and LAPW isolation (PVAI+LAPW) versus PVAI alone on the outcome of ablation of persistent AF. METHODS: During the first procedure, PVAI was performed in 20 patients (group 1), whereas in 32 patients (group 2), PVAI was extended to the left atrial (LA) septum and coronary sinus (CS), and isolation of the LAPW was targeted (ePVAI+LAPW). Isolation of the superior vena cava was achieved in both groups. All patients, regardless of arrhythmia recurrence, underwent a second procedure 3 months after the first procedure. In patients with reconnection of pulmonary veins or LAPW, reisolation was performed, and a third procedure was performed 3 months later to verify isolation. Patients entered follow-up only after PVAI (group 1) or PVAI+LAPW (group 2) isolation was proven. RESULTS: At the 1-, 2-, and 3-year follow-up examinations, the rates of freedom from atrial tachyarrhythmia without use of an antiarrhythmic drug were 20%, 15%, and 10% in group 1 and 65%, 50%, and 40% in group 2, respectively (log-rank P < .001). The median recurrence-free survival time was 8.5 months (interquartile range 6.5-11.0) in group 1 and 28.0 months (interquartile range 8.5-32.0) in group 2. CONCLUSION: Proven isolation of the LAPW provides additional benefits over PVAI alone in the treatment of persistent AF and improves procedural outcome at follow-up. However, the ablation strategy of ePVAI+LAPW is still associated with a significant high incidence of very late recurrence of atrial tachyarrhythmia. CLINICAL TRIAL REGISTRATION: "Outcome of Atrial Fibrillation Ablation After Permanent Pulmonary Vein Antrum Isolation With or Without Proven Left Atrial Posterior Wall Isolation" (LIBERATION). ClinicalTrials.gov Identifier: NCT01660100.


Atrial Fibrillation , Catheter Ablation , Heart Atria/surgery , Postoperative Complications , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Echocardiography, Transesophageal/methods , Electrocardiography, Ambulatory/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/prevention & control , Secondary Prevention/methods , Secondary Prevention/statistics & numerical data , Treatment Outcome
19.
J Cardiovasc Electrophysiol ; 26(8): 819-825, 2015 Aug.
Article En | MEDLINE | ID: mdl-25884325

BACKGROUND: This study examined incidence of AF following cavotricuspid isthmus (CTI) ablation alone or CTI plus prophylactic pulmonary vein isolation (PVI) in patients presenting with isolated atrial flutter (AFL) with no history of AF. METHODS AND RESULTS: We enrolled 216 patients with isolated typical atrial flutter and randomized them to CTI alone (group 1, n = 108, 61.2 ± 9.7 year, 75% male) or CTI+PVI ablation (group 2, n = 108, 62.4 ± 9.3 year, 73% male). Insertible loop recorder (ILR) was implanted in 21 and 19 patients from groups 1 and 2, respectively. Remaining patients were monitored with event recorders, ECG, 7-day Holter. Follow-up period was for 18 ± 6 months. Compared to group 1, group 2 had significantly longer procedural duration (75.9 ± 33 min vs. 161 ± 48 min [P < 0.001]) and fluoroscopy time (15.9 ± 12.3 min vs. 56.4+21 min [P < 0.001]). At the end of follow-up, 65 (60.2%) in group 1 and 77 (71.3%) in group 2 were arrhythmia free off-AAD (log-rank P = 0.044). A subgroup analysis was performed with 55 year age cut-off. In the <55 age group the CTI only population had similar success as in CTI+PVI, (21 of 24 [83.3%] vs. 19 of 22 [86.4%], respectively, log-rank P = 0.74). In the ≥55 group, having CTI+PVI showed significantly higher success compared to CTI only; 45 of 84 (53.6%) were AF/AT free in CTI only group versus 58 of 86 (67.4%) with CTI+PVI (log-rank P = 0.029). CONCLUSION: Prophylactic PVI reduced new-onset AF in patients with lone atrial flutter.


Atrial Fibrillation/prevention & control , Atrial Flutter/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/epidemiology , Atrial Flutter/physiopathology , Catheter Ablation/adverse effects , Disease-Free Survival , Electrocardiography, Ambulatory , Female , Heart Rate , Humans , Incidence , Italy/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Pilot Projects , Proportional Hazards Models , Pulmonary Veins/physiopathology , Risk Factors , Telemetry , Time Factors , Treatment Outcome , United States/epidemiology
20.
J Am Coll Cardiol ; 66(25): 2872-2882, 2015 Dec 29.
Article En | MEDLINE | ID: mdl-26718674

BACKGROUND: Catheter ablation reduces ventricular tachycardia (VT) recurrence and implantable cardioverter defibrillator shocks in patients with VT and ischemic cardiomyopathy. The most effective catheter ablation technique is unknown. OBJECTIVES: This study determined rates of VT recurrence in patients undergoing ablation limited to clinical VT along with mappable VTs ("clinical ablation") versus substrate-based ablation. METHODS: Subjects with ischemic cardiomyopathy and hemodynamically tolerated VT were randomized to clinical ablation (n = 60) versus substrate-based ablation that targeted all "abnormal" electrograms in the scar (n = 58). Primary endpoint was recurrence of VT. Secondary endpoints included periprocedural complications, 12-month mortality, and rehospitalizations. RESULTS: At 12-month follow-up, 9 (15.5%) and 29 (48.3%) patients had VT recurrence in substrate-based and clinical VT ablation groups, respectively (log-rank p < 0.001). More patients undergoing clinical VT ablation (58%) were on antiarrhythmic drugs after ablation versus substrate-based ablation (12%; p < 0.001). Seven (12%) patients with substrate ablation and 19 (32%) with clinical ablation required rehospitalization (p = 0.014). Overall 12-month mortality was 11.9%; 8.6% in substrate ablation and 15.0% in clinical ablation groups, respectively (log-rank p = 0.21). Combined incidence of rehospitalization and mortality was significantly lower with substrate ablation (p = 0.003). Periprocedural complications were similar in both groups (p = 0.61). CONCLUSIONS: An extensive substrate-based ablation approach is superior to ablation targeting only clinical and stable VTs in patients with ischemic cardiomyopathy presenting with tolerated VT. (Ablation of Clinical Ventricular Tachycardia Versus Addition of Substrate Ablation on the Long Term Success Rate of VT Ablation (VISTA); NCT01045668).


Cardiomyopathies/surgery , Catheter Ablation/methods , Myocardial Ischemia/surgery , Tachycardia, Ventricular/surgery , Aged , Body Surface Potential Mapping/methods , Cardiomyopathies/complications , Cardiomyopathies/physiopathology , Female , Follow-Up Studies , Humans , Male , Myocardial Ischemia/complications , Myocardial Ischemia/physiopathology , Recurrence , Retrospective Studies , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome
...