1 - 20 de 54
2.
Heart Rhythm ; 2024 Feb 23.
Article En | MEDLINE | ID: mdl-38403236

BACKGROUND: Epicardial access is often crucial for successful ventricular tachycardia (VT) ablation, but it is often burdened by significant procedural risk. Intentional coronary vein exit and intrapericardial CO2 insufflation (EpiCO2) can facilitate subxiphoid pericardial access. OBJECTIVE: This prospective study aimed to assess procedural feasibility, safety, and impact of the introduction of intrapericardial CO2 insufflation for epicardial access in a referral center for VT ablation. METHODS: All consecutive patients treated with epicardial VT ablation between November 2022 and January 2024 with the EpiCO2 technique at Pisa University Hospital were prospectively enrolled and compared in terms of feasibility, efficiency, and safety with a local retrospective cohort of patients treated with subxiphoid dry puncture between July 2018 and October 2022. RESULTS: Twenty-two consecutive patients (90.9% male; mean age, 54.3 years) underwent VT ablation with EpiCO2 during the study period. Epicardial access was achieved in all patients; median time from coronary sinus (CS) cannulation to epicardial access was 33 minutes. Intentional vein exit was successful in all cases, whereas CO2 insufflation was not feasible in 1 patient. There were no major complications and no significant bleeding. Since EpiCO2 introduction, epicardial approach utilization increased from 17.8% to 40% of all VT procedures. Comparison with 20 standard dry approach epicardial ablations showed no significant differences in terms of total procedural duration (322.5 [interquartile range, 296.75-363.75] minutes vs 359 [interquartile range, 323-409] minutes; P = .08). CONCLUSION: In our single-center experience, EpiCO2 was feasible and safe and led to significant increase in procedural volume without affecting total procedural time compared with standard dry puncture.

3.
Heart Rhythm O2 ; 4(10): 625-631, 2023 Oct.
Article En | MEDLINE | ID: mdl-37936665

Background: Existing data on the impact of sex differences on transvenous lead extraction (TLE) outcomes in cardiac device patients are limited. Objective: The purpose of this study was to evaluate the safety and efficacy of mechanical TLE in female patients. Methods: A retrospective evaluation was performed on 3051 TLE patients (group 1: female; group 2: male) from a single tertiary referral center. All individuals received treatment using single sheath mechanical dilation and various venous approaches as required. Results: Our analysis included 3051 patients (group 1: 750; group 2: 2301), with a total of 5515 leads handled with removal. Female patients were younger, had a higher left ventricular ejection fraction, and lower prevalences of coronary artery disease and diabetes mellitus. Infection was more common in male patients, whereas lead malfunction or abandonment were more frequent in female patients. Radiologic success was lower in female patients (95.8% vs 97.5%; P = .003), but there was no significant difference in clinical success between groups (97.2% vs 97.5%; P = .872). However, major complications (1.33% vs 0.60%; P <.001) and procedural mortality (0.4% vs 0.1%; P <.001) were higher in females compared to male patients. After multivariate analysis, female sex emerged as the only predictor of major complications, including deaths (odds ratio 3.96; 95% confidence interval 1.39-11.24). Conclusion: TLE using unpowered simple mechanical sheaths in female patients is safe and effective, but is associated with lower radiologic success and higher complication rates and mortality than in males. This finding underscores the importance of recognizing sex differences in TLE outcomes.

4.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37724686

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Humans , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/therapy , Bradycardia , Disease Progression , Adenosine Triphosphate
6.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37536671

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Cardiomyopathies , Channelopathies , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Channelopathies/complications , Channelopathies/therapy , Treatment Outcome , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Cardiomyopathies/complications , Cardiomyopathies/therapy , Registries
7.
Europace ; 25(6)2023 06 02.
Article En | MEDLINE | ID: mdl-37350404

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Defibrillators, Implantable , Humans , Administration, Intravenous , Anti-Bacterial Agents , Hospitalization , Treatment Outcome
8.
Europace ; 25(5)2023 05 19.
Article En | MEDLINE | ID: mdl-36932709

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/diagnosis , Follow-Up Studies , Prospective Studies , Electric Countershock , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy
9.
J Clin Med ; 12(6)2023 Mar 20.
Article En | MEDLINE | ID: mdl-36983388

INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a noninvasive alternative method used in ICU. No data on CNBP reliability are available in the electrophysiology lab during AF ablation, where rhythm variations are common. BACKGROUND: The objective of the present study was to compare continuous noninvasive arterial pressure measured with the ClearSight device (Edwards Lifesciences, Irvine, CA, USA) with invasive radial artery pressure used as the reference method during AF ablation. METHODS: We prospectively enrolled 55 consecutive patients (age 62 ± 11 years, 80% male) undergoing transcatheter AF ablation (62% paroxysmal, 38% persistent) at our center. Standard of care IBP monitoring via a radial cannula and a contralateral noninvasive finger volume-clamp CNBP measurement device were positioned simultaneously in all patients for the entire procedure. Bland-Altman analysis was used to analyze the agreement between the two techniques. RESULTS: A total of 1219 paired measurements for systolic, diastolic, and mean arterial pressure were obtained in 55 subjects, with a mean (SD) of 22 (9) measurements per patient. The mean bias (SD) was -12.97 (13.89) mmHg for systolic pressure (level of agreement -14.24-40.20; correlation coefficient 0.84), -1.85 (8.52) mmHg for diastolic pressure (level of agreement -18.54-14.84; correlation coefficient 0.77) and 2.31 (8.75) mmHg for mean pressure (level of agreement -14.84-19.46; correlation coefficient 0.85). CONCLUSION: In patients undergoing AF ablation, CNBP monitoring with the ClearSight device showed acceptable agreement with IBP monitoring. Larger studies are needed to confirm the potential clinical implications of continuous noninvasive BP monitoring during AF ablation.

10.
Europace ; 25(4): 1423-1431, 2023 04 15.
Article En | MEDLINE | ID: mdl-36794691

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Case-Control Studies , Death, Sudden, Cardiac/etiology , Retrospective Studies , Treatment Outcome
11.
J Interv Card Electrophysiol ; 64(1): 257-264, 2022 Jun.
Article En | MEDLINE | ID: mdl-35412167

BACKGROUND: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. METHODS: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. RESULTS: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. CONCLUSIONS: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.


Defibrillators, Implantable , Mobile Applications , Pacemaker, Artificial , Humans , Monitoring, Physiologic , Multicenter Studies as Topic , Patient Compliance
12.
J Interv Card Electrophysiol ; 64(3): 773-781, 2022 Sep.
Article En | MEDLINE | ID: mdl-35277775

BACKGROUND: The study aimed to explore the resolution of left atrial and left atrial appendage (LAA) spontaneous echo-contrast or thrombus in patients with nonvalvular atrial fibrillation/flutter (AF/AFL) under chronic oral anticoagulation (OAC). METHODS: A single-center retrospective analysis of patients who underwent a transesophageal echocardiography (TOE) for an electrical cardioversion was conducted. RESULTS: Among 277 TOE performed, 73 cases (26%) of LAA echo-contrast or thrombus were detected, 53 patients with LAA/LA echo-contrast (19%) and 20 (7%) with a thrombus. All patients were under chronic anticoagulation with a VKA (65%) or with a NOAC (35%). The Echo-contrast Group maintained the same OAC strategy in 49 patients (93%). The Thrombus Group kept the same OAC strategy with a NOAC in 6 cases (30%) and changed the strategy in 14 patients (70%), titrating NOAC dose in 1 (5%) and the VKA dose in 4 (20%) and switching from NOAC to VKA in 5 (25%), from VKA to NOAC in 3 (15%), and from NOAC to NOAC in 1 (5%). Smoke resolution was observed in 4/40 cases (10%) of the smoke group and thrombus resolution in 8/15 (53%) of the thrombus group. Patients with thrombus resolution had a lower CHA2DS2-Vasc score (3.5 ± 2 vs 4 ± 1, p = 0.05), were more often under NOAC (37.5 vs 28%, p = 0.07), and had a longer anticoagulation time (7.5 vs 4 months, p = 0.08). CONCLUSION (S): Changing OAC strategy is associated with thrombus resolution in more than 50% of chronically anticoagulated patients.


Atrial Appendage , Atrial Fibrillation , Heart Diseases , Thrombosis , Anticoagulants , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/drug therapy , Echocardiography, Transesophageal , Humans , Retrospective Studies , Smoke , Thrombosis/complications , Thrombosis/diagnostic imaging , Thrombosis/prevention & control
14.
Article En | MEDLINE | ID: mdl-35037145

PURPOSE: We evaluated the clinical impact of the high-density (HD) mapping compared with the standard low-density (LD) ablation catheter mapping technique in the treatment of AFLs. METHODS: We retrospectively evaluated short and long outcomes of patients approached with an HD and a LD electro-anatomical strategy for atypical AFLs. RESULTS: Eighty-seven patients were included. Patients were almost male (60%), relatively old (65 ± 8 years), with a moderate CHA2DS2Vasc score (2.3 ± 1.3), a preserved ejection fraction (58 ± 6), and moderate atrial dilatation (44 ± 7 mm). Baseline clinical characteristics were comparable between groups (p = NS). Among AFLs, 10 (11%) were located in the right and 78 (89%) in the left atrium, including 22 (28%) roof dependent and 37 (47%) mitral dependent (p = NS). Sinus rhythm restoration during ablation was more frequently observed in the HD group (79% vs 56%, p = 0.037), without differences in mapping time, procedural time, and radiological dose (p = NS). Overall AFL/AT/AF recurrence rate at 1, 2, and 3 years was lower in the HD group (14% vs 37% p = 0.02, 14% vs 48% p = 0.002 and 14% vs 50% p < 0.001, respectively) with a time-dependent trend only in the LD group (37% vs 48% vs 50% at 1, 2, and 3 years respectively, p = 0.059). HD mapping (OR 0.17; 95% CI 0.04-0.66) and younger age (OR 1.09; 95% CI 1.01-1.19) resulted independent predictors of overall arrhythmias at follow-up. CONCLUSIONS: Short- and long-term outcomes of atypical AFL ablation were better in the case of HD mapping, which resulted independent predictor of arrhythmia recurrences.

15.
Int J Cardiol Heart Vasc ; 38: 100952, 2022 Feb.
Article En | MEDLINE | ID: mdl-35071727

BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations. METHODS: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD. RESULTS: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values. CONCLUSIONS: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.

16.
J Cardiovasc Electrophysiol ; 33(1): 81-89, 2022 01.
Article En | MEDLINE | ID: mdl-34797012

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. OBJECTIVE: To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. METHODS: Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. RESULTS: 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). CONCLUSIONS: Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.


Defibrillators, Implantable , Heart Failure , Defibrillators, Implantable/adverse effects , Female , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/therapy , Humans , Stroke Volume , Surveys and Questionnaires , Treatment Outcome
18.
Front Cardiovasc Med ; 8: 692943, 2021.
Article En | MEDLINE | ID: mdl-34395560

Background: When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction. Methods: We analyzed all consecutive patients who underwent S-ICD implantation after abandonment of malfunctioning leads and compared their outcomes with those of patients who underwent extraction and subsequent reimplantation of a single-chamber transvenous ICD (T-ICD). Results: Forty-three patients underwent S-ICD implantation after abandonment of malfunctioning leads, while 62 patients underwent extraction and subsequent reimplantation of a new T-ICD. The two groups were comparable. In the extraction group, no major complications occurred during extraction, while the procedure failed and an S-ICD was implanted in 4 patients. During a median follow-up of 21 months, 3 major complications or deaths occurred in the S-ICD group and 11 in the T-ICD group (HR 1.07; 95% CI 0.29-3.94; P = 0.912). Minor complications were 4 in the S-ICD group and 5 in the T-ICD group (HR 2.13; 95% CI 0.49-9.24; P = 0.238). Conclusions: In the event of ICD lead malfunction, extraction avoids the potential long-term risks of abandoned leads. Nonetheless the strategy of lead abandonment and S-ICD implantation was feasible and safe, with no significant increase in adverse outcomes, and may represent an option in selected clinical settings. Further studies are needed to fully understand the potential risks of lead abandonment. Clinical Trial Registration: URL: ClinicalTrials.gov Identifier: NCT02275637.

19.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Article En | MEDLINE | ID: mdl-33969578

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Defibrillators, Implantable , Body Mass Index , Electric Countershock/adverse effects , Electric Impedance , Humans , Prosthesis Implantation/adverse effects , Subcutaneous Tissue , Treatment Outcome
20.
JACC Clin Electrophysiol ; 7(6): 767-776, 2021 06.
Article En | MEDLINE | ID: mdl-33516714

OBJECTIVES: This study evaluated the efficacy of conversion test performed at 40 J (defibrillation margin ≥40 J), and factors potentially associated with test failure were identified. BACKGROUND: Current subcutaneous implantable cardioverter-defibrillator (S-ICD) devices deliver a maximum of 80 J. Functional defibrillation testing is recommended at S-ICD implantation, and it is usually conducted by delivering a shock energy of 65 J to ensure a safety defibrillation margin ≥15 J. Although high rates of successful conversion were reported at 65 J, limited data exist on the defibrillation margin extent. METHODS: Ventricular fibrillation was induced and conversion test was performed by delivering a 40-J shock in 308 patients. Success was defined as termination of ventricular fibrillation by the first shock delivered in standard polarity. The S-ICD system positioning was evaluated with the PRAETORIAN score using bidirectional chest X-rays. RESULTS: The generator was positioned in an intermuscular pocket in 301 patients (98%) and the lead was implanted by means of a 2-incision technique. The PRAETORIAN score was <90 (low risk of conversion failure) in 293 (95%) patients. Overall, ventricular fibrillation termination occurred in 259 (84%) patients with 40 J. Male gender (odds ratio [OR]: 3.79; 95% confidence interval [CI]: 1.09 to 13.14; p = 0.036), body mass index (OR: 1.09; 95% CI: 1.01 to 1.19; p = 0.036), dilated cardiomyopathy with reduced ejection fraction (OR: 0.42; 95% CI: 0.20 to 0.87; p = 0.019), and PRAETORIAN score >50 (OR: 2.93; 95% CI: 1.26 to 6.83; p = 0.013) were independently associated with conversion failure. CONCLUSIONS: The authors showed a high rate of defibrillation success with 40-J shocks in S-ICD systems implanted by means of modern surgical techniques. The variables associated with shock failure were male gender, higher body mass index, and suboptimal device position according to the PRAETORIAN score.


Defibrillators, Implantable , Arrhythmias, Cardiac , Defibrillators, Implantable/adverse effects , Humans , Male , Ventricular Fibrillation/therapy
...