Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.300
1.
Clin Orthop Surg ; 16(3): 485-493, 2024 Jun.
Article En | MEDLINE | ID: mdl-38827755

Background: Sagittal talar translation is an important factor influencing the sagittal alignment of total ankle arthroplasty (TAA). Thus, accurate measurement of sagittal talar translation is crucial. This study proposes a simple method (tibiotalar distance [TTD]) that can quantify talar translation without being affected by the ankle and subtalar joint condition or the talar component position in patients with TAA. Methods: We enrolled 280 eligible patients (296 ankles) who underwent primary TAA between 2005 and 2019 and retrospectively reviewed them for sagittal talar translation. The TTD was measured for each patient on weight-bearing lateral ankle radiographs by 3 raters. In addition, we analyzed interrater and intrarater reliability for the TTD method. Results: We found that the TTD method could quantify the talar translation and was not affected by the preoperative condition of the ankle joint surface, subtalar joint pathologies, or the postoperative talar component position. The TTD method showed an excellent intraclass correlation coefficient (> 0.9) in all interrater and intrarater reliability analyses. In the analysis of 157 healthy, unoperated contralateral ankles, we identified that TTD showed a Gaussian distribution (p = 0.284) and a mean of 38.91 mm (normal range, 29.63-48.20 mm). Conclusions: The TTD method is a simple and reliable method that could be applied to patients with TAA to assess the sagittal talar translation regardless of the pre-and postoperative joint condition and implantation status.


Arthroplasty, Replacement, Ankle , Talus , Humans , Arthroplasty, Replacement, Ankle/methods , Male , Female , Middle Aged , Retrospective Studies , Aged , Talus/diagnostic imaging , Talus/surgery , Adult , Reproducibility of Results , Tibia/diagnostic imaging , Tibia/surgery , Ankle Joint/diagnostic imaging , Ankle Joint/surgery , Aged, 80 and over , Radiography
2.
Clin Orthop Surg ; 16(3): 455-460, 2024 Jun.
Article En | MEDLINE | ID: mdl-38827760

Background: Total ankle arthroplasty (TAA) enhances patients' subjective outcomes with respect to pain and function. The aim of this study was to analyze the biomechanical changes of the affected limb following TAA using gait analysis with a 3-dimensional multi-segment foot model (3D MFM). Methods: We reviewed medical records, simple radiographs, and gait analyses using a 3D MFM of patients who underwent TAA for severe varus ankle arthritis. Preoperative and postoperative gait data of 24 patients were compared. Postoperative gait analyses were done at least 1 year after surgery. Results: TAA significantly increased stride length (p = 0.024). The total range of motion of all planes in the hindfoot and forefoot showed no significant changes between preoperative and postoperative states. Hindfoot was significantly plantarflexed and pronated after TAA, while forefoot was significantly supinated in all phases. After appropriate calculations, the genuine coronal motion of the hindfoot showed no changes after TAA in all phases. Conclusions: TAA did not result in biomechanical improvements of segmental motions in the forefoot and hindfoot, except for changes to the bony structures. Therefore, it is important to point out to patients that TAA will not result in significant improvement of ankle function and range of motion. Clinicians can consider this information during preoperative counseling.


Arthroplasty, Replacement, Ankle , Range of Motion, Articular , Humans , Male , Female , Middle Aged , Aged , Ankle Joint/surgery , Ankle Joint/physiopathology , Ankle Joint/diagnostic imaging , Biomechanical Phenomena , Gait Analysis , Imaging, Three-Dimensional , Retrospective Studies , Gait/physiology , Aged, 80 and over
3.
Bull Hosp Jt Dis (2013) ; 82(2): 159-163, 2024 Jun.
Article En | MEDLINE | ID: mdl-38739665

Ankle arthritis is becoming more common and can be pain-ful and debilitating. As the disease progresses, degenera-tive cystic changes may be found in the distal fibula, distal tibia, and talus. After failure of non-operative modalities, arthrodesis is often considered the surgical intervention of choice, but this leaves the patient with reduced range of motion, altered gait, and can negatively impact adjacent joints of the foot. Total ankle arthroplasty has been found to be an effective surgical option for ankle arthritis but is contraindicated in patients with talar collapse. When this is the case, a more personalized approach for preserving ankle motion is necessary. We present the case of a 65-year-old male with severe right ankle arthritis and talar collapse treated with a custom three-dimensionally printed talus and concurrent total ankle replacement with 2-year follow-up.


Ankle Joint , Arthroplasty, Replacement, Ankle , Joint Prosthesis , Osteoarthritis , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Male , Arthroplasty, Replacement, Ankle/methods , Arthroplasty, Replacement, Ankle/instrumentation , Aged , Osteoarthritis/surgery , Osteoarthritis/physiopathology , Osteoarthritis/diagnostic imaging , Talus/surgery , Talus/diagnostic imaging , Talus/physiopathology , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Ankle Joint/physiopathology , Treatment Outcome , Range of Motion, Articular
4.
Comput Biol Med ; 175: 108551, 2024 Jun.
Article En | MEDLINE | ID: mdl-38703546

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Algorithms , Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Humans , Tibia/surgery , Tibia/diagnostic imaging , Arthroplasty, Replacement, Ankle/instrumentation , Tomography, X-Ray Computed , Models, Biological , Osseointegration/physiology , Bone-Implant Interface/diagnostic imaging , Joint Prosthesis
6.
Gait Posture ; 111: 176-181, 2024 Jun.
Article En | MEDLINE | ID: mdl-38705035

BACKGROUND: As total ankle arthroplasty (TAA) is an increasingly common surgical intervention for patients with end-stage ankle arthritis, there is a need to better understand the dynamic performance of prosthetic implants during activities of daily living. Our purpose was to quantify and compare relative tibiotalar motion during gait in persons with a fixed-bearing (FB) and mobile-bearing (MB) total ankle arthroplasty. We hypothesized a FB prosthesis would have lower tibiotalar range of motion (ROM). METHODS: Patients at least 12 months postoperative with either a FB (n=5) or MB (n=3) total ankle arthroplasty were tested. We used high-speed biplanar videoradiography to quantify tibiotalar kinematics during self-selected gait. Angular and linear ROM in three axes were compared between the groups. RESULTS: ROM for dorsiflexion-plantarflexion, internal-external rotation, and inversion-eversion angles in FB subjects averaged 7.47±4.05°, 7.39±3.63°, and 4.51±2.13°, respectively. ROM in MB subjects averaged 6.74±2.04°, 6.28±4.51°, and 5.68±2.81°, respectively. Linear ROM along anteroposterior, mediolateral, and superior-inferior axes in FB subjects averaged 1.47±2.07 mm, 1.13±1.49 mm, and 0.28±0.30 mm, respectively. Linear ROM in MB subjects averaged 0.68±1.44 mm, 0.60±1.41 mm, and 0.20±0.13 mm, respectively. We found no significant difference between the two groups for any of these ROM parameters (p>0.05). CONCLUSION: Total ankle arthroplasty using either FB or MB design appears to confer similar ankle motion during the gait cycle in this biplanar fluoroscopic model. LEVEL OF EVIDENCE: Level IV, case series.


Ankle Joint , Arthroplasty, Replacement, Ankle , Feasibility Studies , Range of Motion, Articular , Humans , Range of Motion, Articular/physiology , Biomechanical Phenomena , Male , Female , Ankle Joint/surgery , Ankle Joint/physiopathology , Middle Aged , Aged , Fluoroscopy , Joint Prosthesis , Gait/physiology , Prosthesis Design , Imaging, Three-Dimensional , Arthritis/surgery , Arthritis/physiopathology
7.
J Biomed Mater Res B Appl Biomater ; 112(5): e35417, 2024 May.
Article En | MEDLINE | ID: mdl-38742468

Stress shielding is one of the major concerns for total ankle replacement implants nowadays, because it is responsible for implant-induced bone resorption. The bone resorption contributes to the aseptic loosening and failure of ankle implants in later stages. To reduce the stress shielding, improvements can be made in the implant material by decreasing the elastic mismatch between the implant and the tibia bone. This study proposes a new functionally graded material (FGM) based tibial implant for minimizing the problem of stress shielding. Three-dimensional finite element (FE) models of the intact tibia and the implanted tibiae were created to study the influence of material gradation law and volume fraction index on stress shielding and implant-bone micromotion. Different implant materials were considered that is, cobalt-chromium, titanium (Ti), and FGM with Ti at the bottom and hydroxyapatite (HA) at the top. The FE models of FGM implants were generated by using different volume fractions and the rule of mixtures. The rule of mixtures was used to calculate the FGM properties based on the local volume fraction. The volume fraction was defined by using exponential, power, and sigmoid laws. For the power and sigmoid law varying volume fraction indices (0.1, 0.2, 0.5, 1, 2, and 5) were considered. The geometry resembling STAR® ankle system tibial implant was considered for the present study. The results indicate that FGMs lower stress shielding but also marginally increase implant-bone micromotion; however, the values were within the acceptable limit for bone ingrowth. It is observed that the material gradation law and volume fraction index influence the performance of FGM tibial implants. The tibial implant composed of FGM using power law with a volume fraction index of 0.1 was the preferred option because it showed the least stress shielding.


Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Titanium , Titanium/chemistry , Humans , Durapatite/chemistry , Prosthesis Design , Stress, Mechanical , Materials Testing
8.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241244825, 2024.
Article En | MEDLINE | ID: mdl-38607239

PURPOSE: This study aims to systematically review the efficacy and safety of total ankle replacement (TAR) and ankle fusion (AF) as treatment options for end-stage ankle arthritis. METHODS: A comprehensive literature search was conducted on data from multiple databases, including PubMed, The Cochrane Library, Construction and Building Materials, Embase, Web of Science, and Scopus for RCTs and prospective cohort studies comparing TAR and AF in patients with end-stage ankle arthritis from inception up to June, 2023. Our primary outcomes of interest included patients' clinical function scores and complications. We employed Review Manager 5.4 and Stata/MP 14.0 software for the meta-analysis. RESULTS: Our analysis incorporated 13 comparative studies, including 11 prospective studies, one pilot RCT, and one RCT. The pooled results revealed no significant difference in postoperative Short Form-36 scores between the TAR and AF groups (MD = -1.19, 95% CI: -3.89 to 1.50, p = .39). However, the postoperative Foot and Ankle Ability Measure scores in the AF group were significantly higher than in the TAR group (MD = 8.30, 95% CI: 1.01-15.60, p = .03). There was no significant difference in postoperative complication rates between the TAR and AF groups (RR = 0.95, 95% CI: 0.59 to 1.54, p = .85). CONCLUSION: Currently available evidence suggests no significant disparity in postoperative outcomes between TAR and AF. In the short term, TAR demonstrates better clinical scores than AF and lower complication rates. Conversely, in the long term, AF exhibits superior clinical scores and lower complication rates, although this difference is not statistically significant.


Arthritis , Arthroplasty, Replacement, Ankle , Humans , Ankle , Prospective Studies , Ankle Joint/surgery , Arthritis/surgery
9.
Bone Joint J ; 106-B(5): 475-481, 2024 May 01.
Article En | MEDLINE | ID: mdl-38688515

Aims: The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods: We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results: Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion: Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting.


Arthroplasty, Replacement, Ankle , Bone Cysts , Bone Transplantation , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Ankle/methods , Arthroplasty, Replacement, Ankle/adverse effects , Bone Cysts/surgery , Bone Cysts/diagnostic imaging , Bone Cysts/etiology , Female , Male , Middle Aged , Bone Transplantation/methods , Aged , Retrospective Studies , Adult , Treatment Outcome , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Follow-Up Studies
10.
Foot Ankle Int ; 45(5): 426-434, 2024 May.
Article En | MEDLINE | ID: mdl-38482821

BACKGROUND: Although intraoperative ankle motion serves as a foundational reference for anticipated motion after surgery and guides the addition of procedures to enhance ankle motion in total ankle arthroplasty (TAA), the relationship between intraoperative and postoperative ankle motion remains unclear. This study aimed to investigate the discrepancy between intraoperative and postoperative ankle range of motion (ROM) following TAAs using the anterior-approach, fixed-bearing systems. METHODS: This study retrospectively reviewed 67 patients (67 ankles) who underwent primary TAA at a single institution. Three different types of anterior-approach, fixed-bearing TAA systems were included. Intraoperative fluoroscopy was used to document the maximal dorsiflexion and plantar flexion at the end of the case. Standardized weightbearing maximum dorsiflexion and plantar flexion sagittal radiographs were obtained pre- and postoperatively, following a previously described method. The motion between 3 different time points (preoperative, intraoperative, and postoperative [mean 11.4 months]) was compared using pairwise t tests, and their differences were quantified. RESULTS: The mean total tibiotalar ROM was 38.1 degrees (SD 7.8) intraoperatively, and the postoperative total tibiotalar ROM was 24.2 degrees (SD 9.7) (P < .001), indicating that a mean of 65.3% (SD 26.7) of the intraoperative motion was maintained postoperatively. Intraoperative dorsiflexion (mean 11.6 [SD 4.5] degrees) showed no evidence of difference from postoperative dorsiflexion (mean 11.4 [SD 5.8] degrees, P > .99), indicating that a median of 95.6% (interquartile range: 66.2-112) of the intraoperative maximum dorsiflexion was maintained postoperatively. However, there was a significant difference between intraoperative plantarflexion (mean 26.4 [SD 6.3]) and postoperative plantarflexion (12.8 [SD 6.9] degrees, P < .001), indicating a mean 50.6% (SD 29.6) of intraoperative motion maintained in the postoperative assessment. There was an improvement of 2.5 degrees in the total tibiotalar ROM following TAA with statistical significance (P < .043). CONCLUSION: This study revealed a significant difference between intraoperative ankle ROM and ankle ROM approximately 1 year after anterior-approach, fixed-bearing TAA, mainly due to plantarflexion motion restriction. Minimal difference in dorsiflexion suggests the importance of achieving the desired postoperative dorsiflexion motion during the surgery using the best possible adjunct procedures. LEVEL OF EVIDENCE: Level IV, case series.


Ankle Joint , Arthroplasty, Replacement, Ankle , Range of Motion, Articular , Humans , Range of Motion, Articular/physiology , Retrospective Studies , Ankle Joint/surgery , Ankle Joint/physiopathology , Aged , Middle Aged , Female , Male , Fluoroscopy , Postoperative Period , Weight-Bearing/physiology , Intraoperative Period
11.
J Bone Joint Surg Am ; 106(9): 767-775, 2024 May 01.
Article En | MEDLINE | ID: mdl-38442190

BACKGROUND: Total ankle replacements (TARs) have rapidly advanced in terms of volume, technique, design, and indications. However, TARs are still at risk for early mechanical failure and revision. Prior studies have investigated potential risk factors for failure, but have been limited to smaller series or older implants. This study sought to identify risk factors for early mechanical failure in modern TAR. METHODS: This is a retrospective study of a single-institution registry. Five surgeons contributed cases involving patients who underwent a primary TAR with any implant. Implants were grouped on the basis of the type of fixation. The primary outcome was early mechanical failure (revision with component removal for a non-infectious etiology, that is, subsidence, aseptic loosening, and/or malalignment). Logistic regression determined the effects of age, weight, hindfoot arthrodesis, implant type, and radiographic deformity on failure. RESULTS: The 731 included patients had a mean follow-up of 2.7 years. Ten percent (71 patients) had hindfoot arthrodesis. There were 33 mechanical failures (4.5%) at a mean of 1.7 years after the index surgical procedure. Our model demonstrated that hindfoot arthrodesis was associated with 2.7 times greater odds of failure (p = 0.045), every 10 kg of body weight increased the odds of tibial-sided failure by 1.29 times (p = 0.039), and implants with more extensive tibial fixation (stems or keels) lowered the odds of tibial failure by 95% (p = 0.031). CONCLUSIONS: In patients with uncontrollable risk factors (hindfoot arthrodesis) or risk factors that may or may not be modifiable by the patient (weight), implants with more robust tibial fixation may be able to reduce the risk of early mechanical failure. Further research is warranted to support efforts to decrease early failure in TAR. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Arthroplasty, Replacement, Ankle , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Ankle/instrumentation , Arthroplasty, Replacement, Ankle/adverse effects , Arthroplasty, Replacement, Ankle/methods , Male , Female , Retrospective Studies , Middle Aged , Risk Factors , Aged , Reoperation/statistics & numerical data , Joint Prosthesis/adverse effects , Prosthesis Design , Ankle Joint/surgery , Arthrodesis/instrumentation , Arthrodesis/methods , Arthrodesis/adverse effects , Adult
12.
Eur J Orthop Surg Traumatol ; 34(4): 1945-1956, 2024 May.
Article En | MEDLINE | ID: mdl-38472436

PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the prevalence and clinical significance of heterotopic ossification (HO) following total ankle replacement (TAR). METHODS: During August 2023, the PubMed, Embase and Cochrane library databases were systematically reviewed to identify clinical studies reporting HO following TAR. Data regarding surgical characteristics, pathological characteristics, subjective clinical outcomes, ankle range of motion, radiographic outcomes, reoperation rates were extracted and analysed. RESULTS: Twenty-seven studies with 2639 patients (2695 ankles) at a weighed mean follow-up time of 52.8 ± 26.9 months were included. The pooled prevalence rate was 44.6% (0.25; 0.66). The implant with the highest rate of HO was the INBONE I (100%) and BOX (100%) implants. The most common modified Brooker staging was grade 1 (132 patients, 27.0%). Random effects models of standardized mean differences found no difference in American orthopedic foot and ankle society (AOFAS) scores, visual analog scale scores (VAS) and ankle range of motion (ROM) between patients with HO and patients without HO. Random effects models of correlation coefficients found no correlation between AOFAS, VAS and ROM and the presence of HO. The surgical intervention rate for symptomatic HO was 4.2%. CONCLUSION: This systematic review and meta-analysis found that HO is a common finding following TAR that is not associated with inferior clinical outcomes. Surgical intervention was required only for moderate-to-severe, symptomatic HO following TAR. This study is limited by the marked heterogeneity and low level and quality of evidence of the included studies. Further higher quality studies are warranted to determine the precise prevalence and impact of HO on outcomes following TAR.


Arthroplasty, Replacement, Ankle , Ossification, Heterotopic , Postoperative Complications , Range of Motion, Articular , Ossification, Heterotopic/etiology , Ossification, Heterotopic/epidemiology , Humans , Arthroplasty, Replacement, Ankle/adverse effects , Postoperative Complications/etiology , Ankle Joint/surgery , Ankle Joint/physiopathology , Reoperation/statistics & numerical data , Prevalence
13.
Eur J Orthop Surg Traumatol ; 34(4): 1997-2001, 2024 May.
Article En | MEDLINE | ID: mdl-38502343

BACKGROUND: End stage ankle osteoarthritis (OA) is debilitating. Surgical management consists of either ankle arthrodesis (AA) or a total ankle replacement (TAR). The purpose of this study is to assess the trends in operative intervention for end stage ankle OA in an Australian population. METHODS: This is a retrospective epidemiological study of 15,046 surgeries. Data were collected from publicly available national registries including the Australian Medicare Database and Australian Orthopaedic Association National Joint Replacement Registrar from 2001 to 2020. RESULTS: There was a significant increase in all ankle surgeries performed across the period of interest. AA remained the more commonly performed procedure throughout the course of the study (11,946 cases, 79.4%) and was never surpassed by TAR (3100, 20.6%). The overall proportions demonstrated no significant changes from 2001 to 2020. CONCLUSION: The incidence of ankle surgeries continues to increase with the ageing and increasingly comorbid population of Australia. Despite demonstrating no significant overall change in the ratio of TAR and AA in our study population and period, there are noticeable trends within the timeframe, with a recent surge favouring TAR in the last 5 years.


Ankle Joint , Arthrodesis , Arthroplasty, Replacement, Ankle , Osteoarthritis , Humans , Arthrodesis/statistics & numerical data , Arthrodesis/trends , Arthrodesis/methods , Arthroplasty, Replacement, Ankle/statistics & numerical data , Arthroplasty, Replacement, Ankle/trends , Australia/epidemiology , Osteoarthritis/surgery , Osteoarthritis/epidemiology , Retrospective Studies , Male , Ankle Joint/surgery , Female , Aged , Middle Aged , Registries
14.
Med Biol Eng Comput ; 62(6): 1639-1654, 2024 Jun.
Article En | MEDLINE | ID: mdl-38321323

The use of mechanoregulatory schemes based on finite element (FE) analysis for the evaluation of bone ingrowth around porous surfaces is a viable approach but requires significant computational time and effort. The aim of this study is to develop a combined macro-micro FE and artificial neural network (ANN) framework for rapid and accurate prediction of the site-specific bone ingrowth around the porous beaded-coated tibial implant for total ankle replacement (TAR). A macroscale FE model of the implanted tibia was developed based on CT data. Subsequently, a microscale FE model of the implant-bone interface was created for performing bone ingrowth simulations using mechanoregulatory algorithms. An ANN was trained for rapid and accurate prediction of bone ingrowth. The results predicted by ANN are well comparable to FE-predicted results. Predicted site-specific bone ingrowth using ANN around the implant ranges from 43.04 to 98.24%, with a mean bone ingrowth of around 74.24%. Results suggested that the central region exhibited the highest bone ingrowth, which is also well corroborated with the recent explanted study on BOX®. The proposed methodology has the potential to simulate bone ingrowth rapidly and effectively at any given site over any implant surface.


Arthroplasty, Replacement, Ankle , Finite Element Analysis , Neural Networks, Computer , Tibia , Humans , Arthroplasty, Replacement, Ankle/instrumentation , Arthroplasty, Replacement, Ankle/methods , Tibia/surgery , Porosity , Prostheses and Implants , Coated Materials, Biocompatible/chemistry
15.
Foot Ankle Surg ; 30(4): 275-284, 2024 Jun.
Article En | MEDLINE | ID: mdl-38388212

BACKGROUND: Main objective of this research is to know if there is a different survival rate between fixed bearing (FB) and mobile bearing (MB) total ankle replacement (TAR). We hypothesized that there are no differences between the survival rates of both implants. METHODS: A systematic search was performed in PubMed, Cochrane, EMBASE and ClinicalTrials.gov databases to identify published studies from August 2018 to September 2022 including results for FB and MB TAR survivorship. Inclusion criteria included 1) primary TAR in one or both feet in which implant could be identified , 2) a minimum of 20 procedures reported, 3) reported implant survivorship or calculable and 4) a minimum of 12 months follow-up for level 1-3 studies or 60 months for level 4 studies. RESULTS: 3902 ankles in 28 studies were included. 719 were FB and 3104 MB with an overall survivorship of 94% (95% CI [0.89; 0.97]) and 89% (95% CI [0.86; 0.92]) respectively. After subgroup analysis, we did not find differences among both groups (p =  0.429 ). Meta-regression analysis showed that longer follow-up was associated with lower survival rates in MB group (p = 0.000) while no other relationships were found with other factors (age, level of evidence or conflict of interests). CONCLUSIONS: No differences in survival rates between both groups were found. Age and other studied confounders were not found to be related with implant survivorship. However, longer follow-up was found to be related with lower survival rates. Studies with longer follow-up and higher level of evidence are needed to confirm results. LEVEL OF EVIDENCE: IV, systematic review of level I to IV studies.


Arthroplasty, Replacement, Ankle , Joint Prosthesis , Prosthesis Failure , Humans , Arthroplasty, Replacement, Ankle/instrumentation , Prosthesis Design , Ankle Joint/surgery
16.
Surgeon ; 22(3): 174-181, 2024 Jun.
Article En | MEDLINE | ID: mdl-38360453

BACKGROUND: This study evaluates the clinical outcomes of contemporary total ankle arthroplasty (TAAs) to primarily establish the current benefits and risks to facilitate informed decision making to secondarily establish if improvements are seen between subsequent generations of implants, bearing philosophy, and associated surgical technique. METHODS: A systematic review and meta-analysis of published data from January 2000 to January 2020 was conducted following PRISMA guidelines. INCLUSION CRITERIA: English language papers, adult population, ≥20 ankles with a minimum follow up ≥24 months, pre- and post-operative functional scores available. Ankle implants were characterised by generations, which were determined from the original studies and confirmed based on literature set definitions. RESULTS: A total of 4642 TAAs in 4487 patients from 51 studies were included. The mean age was 61.9-years and follow up 57.8-months. Overall, 10-year survivorship rates were 77.63 %, with mobile bearing designs showing a small but significant advantage. Improved survivorship favoured the most modern implants at both two (p < 0.05), and 10-years (p < 0.01). The relative risk of a complication occurring improved with the evolution of implants e.g., nerve injury, and post-operative complications such as fracture, wound complications (e.g., dehiscence or heamatoma) and radiological abnormalities (e.g., radiolucencies, heterotopic bone formation and aseptic loosening). However, surgical site infection, and intra-operative fracture rates remain implant independent. CONCLUSIONS: Modern TAA offers improved survivorship, even with a trend to lower mean implantation age, similar complexity and ever changing indications. It would appear that implant evolution has reduced risks, especially those associated with revision, without affecting functional outcomes.


Arthroplasty, Replacement, Ankle , Postoperative Complications , Humans , Arthroplasty, Replacement, Ankle/adverse effects , Postoperative Complications/epidemiology , Prosthesis Failure , Joint Prosthesis/adverse effects , Prosthesis Design
17.
J Orthop Res ; 42(7): 1536-1544, 2024 Jul.
Article En | MEDLINE | ID: mdl-38327023

The success of uncemented total ankle replacement (TAR) is linked to initial stability because bony ingrowth depends upon limited early micromotion. Tibial implant design fixation features resist micromotion aided by bony sidewall retention and interference fit. Our goal was to investigate factors influencing implant-bone micromotion in TAR. Two TAR tibial components were virtually inserted into CT-derived computer models of two distal tibias from patients with end-stage ankle arthritis. Density-based inhomogeneous material assignment was used to model bone compaction during press-fit. Finite element analysis (FEA) was used to simulate three fixation cases: (1) no sidewalls + line-to-line fit, (2) sidewalls + line-to-line fit, and (3) sidewalls + 50, 100, or 200 µm interference fit. Kinetic profiles from the stance phase of gait were simulated and micromotions computed from FEA output. Without sidewalls or interference fit, micromotions were largest in early and late stance, with largest micromotions (averaging ~150-250 µm) observed near heel strike. Micromotions decreased 39%-62% when sidewalls were retained. When interference fit was also modeled, micromotions decreased another 37%-61% to ~10 µm. Micromotion differences between patients persisted with sidewall retention but largely disappeared with interference fit. This study presents new insights into the effects of TAR fixation features on implant-bone micromotion. Stability appeared to be influenced by surrounding bone quality, but this influence was greatly diminished when interference fit was introduced. More complete understanding of TAR implant features and performance is needed, but our results show the importance of bone quality and interference fit in the stability of uncemented TAR.


Arthroplasty, Replacement, Ankle , Finite Element Analysis , Humans , Arthroplasty, Replacement, Ankle/instrumentation , Prosthesis Design , Tibia/surgery , Male , Middle Aged , Aged , Female , Ankle Joint/surgery , Joint Prosthesis
18.
Orthop Clin North Am ; 55(2): 285-297, 2024 Apr.
Article En | MEDLINE | ID: mdl-38403374

As the number of primary total ankle replacements increases for treatment of end-stage ankle arthritis, failures are also expected to rise. Periprosthetic joint infection is among the causes of failures and has been reported to be as high as 5%. Diagnosis is usually made by a combination of clinical examination findings, imaging, laboratory, and microbiological workup. Management is generally separated into limb salvage or amputation. Limb salvage can be challenging and may involve a single versus staged approach. Options include revision arthroplasty or arthrodesis procedures (ankle versus tibiotalocalcaneal), and a multidisciplinary approach is sought to eradicate infection before definitive management.


Arthritis, Infectious , Arthroplasty, Replacement, Ankle , Humans , Arthroplasty, Replacement, Ankle/adverse effects , Arthroplasty, Replacement, Ankle/methods , Ankle Joint/surgery , Ankle/surgery , Arthrodesis/adverse effects , Arthrodesis/methods , Reoperation , Treatment Outcome , Retrospective Studies
19.
J Biomech ; 164: 111941, 2024 Feb.
Article En | MEDLINE | ID: mdl-38325194

Total ankle arthroplasty (TAA) is a common surgical solution for patients with debilitating arthritis of the ankle. Prior to surgery patients experience high levels of pain and fatigue and low mechanical energy recovery. It is not known if TAA restores healthy levels of mechanical energy recovery in this patient population. This study was designed to determine whether mechanical energy recovery was restored following TAA. Ground reaction forces during self-selected speed walking were collected from patients with symptomatic, unilateral ankle arthritis (N = 29) before and one and two years after primary, unilateral TAA. The exchange of potential (PE) and kinetic (KE) energy was examined, and direction of change (%congruity) and energy exchange (%recovery) between the two curves was calculated, with those subjects with low congruity experiencing high energy recovery. Linear regressions were used to examine the impact of walking speed, congruity, and amplitude of the center of mass (COM) displacement on %recovery, while ANOVA and ANCOVA models were used to compare energy recovery and congruity across the three time points. Gender, BMI, and age at surgery had no effect in this study. TAA improved walking speed (p = 0.001), increased energy recovery (p = 0.020), and decreased congruity (p = 0.002), and these levels were maintained over at least two years. Differences in congruity were independent of walking speed. In some patients, especially those who are severely debilitated by ankle arthritis, TAA is effective in restoring mechanical energy recovery to levels similar to an asymptomatic population of a similar age recorded by other studies.


Arthritis , Arthroplasty, Replacement, Ankle , Humans , Gait , Ankle , Walking , Ankle Joint/surgery , Arthritis/surgery , Treatment Outcome , Retrospective Studies
20.
Foot Ankle Clin ; 29(1): 111-122, 2024 Mar.
Article En | MEDLINE | ID: mdl-38309796

Gutter impingement is one of the most common causes of subsequent surgery after total ankle arthroplasty (TAA). Although gutter debridement has been reported to resolve preoperative symptoms early on, persistent pain after surgery, recurrence, and poor functional outcome scores have been described in patients who have undergone reoperation for gutter debridement. The cause of gutter impingement after TAA is multifactorial, and a better understanding of its causes and optimal surgical techniques for intervention is needed.


Ankle , Arthroplasty, Replacement, Ankle , Humans , Reoperation , Ankle/surgery , Retrospective Studies , Arthroplasty, Replacement, Ankle/adverse effects , Arthroplasty, Replacement, Ankle/methods , Ankle Joint/surgery , Treatment Outcome
...