1 - 20 de 5.100
1.
Scand J Clin Lab Invest ; 84(3): 183-192, 2024 May.
Article En | MEDLINE | ID: mdl-38701073

Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.


Blood Specimen Collection , Humans , Blood Specimen Collection/instrumentation , Blood Specimen Collection/methods , L-Lactate Dehydrogenase/blood , Female , Male , Reproducibility of Results , Middle Aged , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/standards , Blood Chemical Analysis/methods , Adult , Sodium/blood , Aged
2.
Talanta ; 276: 126204, 2024 Aug 15.
Article En | MEDLINE | ID: mdl-38728803

Detecting progesterone (P4) concentration in cow serum is essential for monitoring the pregnancy progress after fertilization and is significant for the dairy farming industry and veterinary medicine. This study reports enzyme-free immunomagnetic beads (IMBs)-based competitive immunoassay for detecting P4 by P4-bovine serum albumin (BSA)-modified biosensors. The anti-P4 antibody-conjugated IMBs serve as collectors to capture P4 in undiluted serum samples to prevent the biosensor surface from biosample contamination and as insulated labels to report the electron-transfer resistance signal of electrochemical impedance spectroscopy (EIS) measurement. The IMBs and P4-containing samples were mixed for 15-30 min, capable of obtaining stable P4@IMB complexes. The 0.2-kGauss pulsed magnetic field (PMF) of the 20-s pulse width and 20-s relaxation time applied for 5 min can shorten the immunoreaction time between the P4@IMBs and the P4-BSA-modified biosensor and reduce the IMB's nonspecific adsorption on the biosensor surface. This competitive immunoassay's cut-off value and detection limit were 7.71 ng/mL and 7.33 ng/mL, respectively, which is lower than the serum's P4 plateau concentration (over 8 ng/mL) of dairy cows on days 6-16 of estrus cycles and that in pregnancy. The IMB-based immunoassay combining the PMF attraction and the label-free EIS measurement exhibits promising potential for rapidly detecting P4 in undiluted serum.


Blood Chemical Analysis , Cattle , Immunoassay , Progesterone , Dairying , Animals , Progesterone/blood , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/methods , Blood Chemical Analysis/veterinary , Immunoassay/instrumentation , Immunoassay/methods , Immunoassay/veterinary , Immunomagnetic Separation/veterinary , Pregnancy , Magnetic Fields
3.
Analyst ; 149(12): 3444-3455, 2024 Jun 10.
Article En | MEDLINE | ID: mdl-38738630

Numerous studies have revealed a close correlation between the levels of apolipoproteins (Apos) (including lipoprotein(a) [Lp(a)]) and an increased risk of cardiovascular disease in recent decades. However, clinically, lipid profiling remains limited to the conventional plasma levels of cholesterol, triglyceride, ApoA1, and ApoB, which brings the necessity to quantify more apolipoproteins in human plasma. In this study, we simultaneously quantified 13 apolipoproteins and Lp(a) in 5 µL of human plasma using the LC-MS/MS platform. A method was developed for the precise detection of Lp(a), ApoA1, A2, A5, B, C1, C2, C3, D, E, H, L1, M, and J. Suitable peptides were selected and optimized to achieve clear separation of each peak. Method validation consisting of linearity, sensitivity, accuracy and precision, recovery, and matrix effects was evaluated. The intra-day CV ranged from 0.58% to 14.2% and the inter-day CV ranged from 0.51% to 13.3%. The recovery rates ranged from 89.8% to 113.7%, while matrix effects ranged from 85.4% to 113.9% for all apolipoproteins and Lp(a). Stability tests demonstrated that these apolipoproteins remained stable for 3 days at 4 °C and 7 days at -20 °C. This validated method was successfully applied to human plasma samples obtained from 45 volunteers. The quantitative results of ApoA1, ApoB, and Lp(a) exhibited a close correlation with the results from the immunity transmission turbidity assay. Collectively, we developed a robust assay that can be used for high-throughput quantification of apolipoproteins and Lp(a) simultaneously for investigating related risk factors in patients with dyslipidemia.


Apolipoproteins , Lipoprotein(a) , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Apolipoproteins/blood , Lipoprotein(a)/blood , Chromatography, Liquid/methods , Blood Chemical Analysis/methods , Liquid Chromatography-Mass Spectrometry
4.
Talanta ; 275: 126110, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38631264

Considering that cancer has become the second leading cause of death in humans, it is essential to develop an analytical approach that can sensitively detect tumor markers for early detection. We report an attenuated photoelectrochemical (PEC) immunoassay based on the organic-inorganic heterojunction 10MIL-88B(FeV)/ZnIn2S4 (10M88B(FeV)/ZIS) as a photoactive material for monitoring carcinoembryonic antigen (CEA). The 10M88B(FeV)/ZIS heterojunctions have excellent light-harvesting properties and high electrical conductivity, which are attributed to the advantages of both organic and inorganic semiconductors, namely, remarkable photogenerated carrier separation efficiency and long photogenerated carrier lifetime. Horseradish peroxidase (HRP) in the presence of H2O2 can catalyze 3,3'-diaminofenamide (DAB) producing brown precipitates (oxDAB), which is then loaded onto the 10M88B(FeV)/ZIS heterojunction to reduce the photocurrent and enable the quantitative detection of CEA. Under optimal conditions, the photocurrent values of the PEC biosensor are linearly related to the logarithm of the CEA concentrations, ranging from 0.01 ng mL-1 to 100 ng mL-1 with a detection limit (LOD) of 4.0 pg mL-1. Notably, the accuracy of the PEC biosensor is in agreement with that of the human CEA enzyme-linked immunosorbent assay (ELISA) kit.


Biomarkers, Tumor , Blood Chemical Analysis , Immunoassay , Metal-Organic Frameworks , Vanadium , Metal-Organic Frameworks/chemistry , Metal-Organic Frameworks/ultrastructure , Vanadium/chemistry , Photochemistry/instrumentation , Electrochemical Techniques/instrumentation , Immunoassay/instrumentation , Immunoassay/methods , Biomarkers, Tumor/analysis , Biomarkers, Tumor/blood , Carcinoembryonic Antigen/analysis , Carcinoembryonic Antigen/blood , Humans , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/methods , Limit of Detection
5.
Clin Chem Lab Med ; 62(8): 1557-1569, 2024 Jul 26.
Article En | MEDLINE | ID: mdl-38443327

OBJECTIVES: The pre-analytical stability of various biochemical analytes requires careful consideration, as it can lead to the release of erroneous laboratory results. There is currently significant variability in the literature regarding the pre-analytical stability of various analytes. The aim of this study was to determine the pre-analytical stability of 65 analytes in whole blood, serum and plasma using a standardized approach. METHODS: Blood samples were collected from 30 healthy volunteers (10 volunteers per analyte) into five vacutainers; either SST, Li-heparin, K2-EDTA, or Na-fluoride/K-oxalate. Several conditions were tested, including delayed centrifugation with storage of whole blood at room temperature (RT) for 8 h, delayed centrifugation with storage of whole blood at RT or 4 °C for 24 h, and immediate centrifugation with storage of plasma or serum at RT for 24 h. Percent deviation (% PD) from baseline was calculated for each analyte and compared to the maximum permissible instability (MPI) derived from intra- and inter-individual biological variation. RESULTS: The majority of the analytes evaluated remained stable across all vacutainer types, temperatures, and timepoints tested. Glucose, potassium, and aspartate aminotransferase, among others, were significantly impacted by delayed centrifugation, having been found to be unstable in whole blood specimens stored at room temperature for 8 h. CONCLUSIONS: The data presented provides insight into the pre-analytical variables that impact the stability of routine biochemical analytes. This study may help to reduce the frequency of erroneous laboratory results released due to exceeded stability and reduce unnecessary repeat phlebotomy for analytes that remain stable despite delayed processing.


Blood Specimen Collection , Plasma , Serum , Humans , Blood Specimen Collection/methods , Plasma/chemistry , Serum/chemistry , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Adult , Male , Temperature , Female , Healthy Volunteers , Centrifugation
6.
J Appl Lab Med ; 9(3): 558-564, 2024 May 02.
Article En | MEDLINE | ID: mdl-38300631

BACKGROUND: Hemolysis is a common reason for specimen rejection in the laboratory. Our experience suggested that hemolysis (H) flag limits are too strict for some analytes leading to unnecessary specimen rejections. This study summarizes H flags for commonly rejected analytes on the Beckman Coulter DxC 700 AU analyzer. METHODS: We evaluated analytes with low-limit H flags and high rejection rates. These included: aspartate aminotransferase (AST), alanine aminotransferase (ALT), iron (IRN), potassium (K), direct bilirubin (DBIL), magnesium (Mg), amylase (AMY), sodium (Na), gamma-glutamyltransferase (GGT), phosphorus (PHOS), albumin (ALB), alkaline phosphatase (ALKP), and lactate dehydrogenase (LDH). Five patient plasma pools without hemolysis were made from 50 patient specimens. Neat pools were analyzed to establish baseline analyte concentrations. A hemolysate was created by diluting whole blood with distilled water. Each analyte was tested after spiking each pool with the hemolysate to specific hemoglobin concentrations corresponding to manufacturer's H flags. Percent differences were calculated between baseline pool means and each flag's pool mean. Acceptance limits were based upon the average of the 2019 CLIA and the method precision limits. Calculated percent differences greater than the acceptance limits were considered significant. RESULTS: Manufacturer-defined hemolysis flags can be updated to greater than 1+ for Na, K, and AST, greater than 3+ for ALKP, and greater than 4+ for AMY and Mg. No changes were noted for the remaining analytes. CONCLUSIONS: The hemolysis criteria set for ALKP, AMY, AST, Mg, K, and Na were updated in the Remisol Advance middleware, which led to a 56% reduction in rejected hemolyzed specimens.


Hemolysis , Humans , Bilirubin/blood , Blood Chemical Analysis/methods , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/standards , Aspartate Aminotransferases/blood , Alanine Transaminase/blood , Potassium/blood , Iron/blood , Sodium/blood
7.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Article En | MEDLINE | ID: mdl-38407268

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Phenobarbital , Tandem Mass Spectrometry , Humans , Phenobarbital/blood , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Anticonvulsants/blood , Reference Standards , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Indicator Dilution Techniques , Liquid Chromatography-Mass Spectrometry
9.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Article En | MEDLINE | ID: mdl-38105272

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Isoxazoles , Tandem Mass Spectrometry , Zonisamide , Humans , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Zonisamide/blood , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Isoxazoles/blood , Reference Standards , Indicator Dilution Techniques , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Liquid Chromatography-Mass Spectrometry
10.
Pak J Pharm Sci ; 36(5(Special)): 1597-1607, 2023 Sep.
Article En | MEDLINE | ID: mdl-38008958

A rapid, highly specific and sensitive UPLC-MS/MS method was developed for the determination of Quetiapine Fumarate, a therapeutic drug for various psychiatric disorders, in human plasma. The samples were pretreated using a protein precipitation method, followed by chromatographic separation using a column (Kinetex C18, 2.6µm 50*2.1mm) equipped with an ESI source and MRM mode mass spectrometer. In the validation results of the method, the analyte quetiapine showed a peak at approximately 1.0 minute and exhibited good linearity within the concentration from 2.5 to 2000ng/mL. The intra- and inter-batch precision CV% were within the range of -1.3% to 7.7% and precision of intra- and inter-batch were below 15.0%. Furthermore, this method demonstrated low matrix effects and high recovery rates. The quetiapine plasma sample solution remained stable at room temperature for 25 hours and following 4 freeze-thaw cycles. The prepared samples remained stable in the autosampler (The temperature control of the autosampler was 5oC) for 185 hours and after four freeze-thaw cycles at -20oC and -70oC for 40 days. The present work effectively employed this approach to investigate the pharmacokinetics of orally administered quetiapine fumarate tablets in a cohort of healthy Chinese individuals, both in a fasting state and after a meal.


Blood Chemical Analysis , East Asian People , Quetiapine Fumarate , Tandem Mass Spectrometry , Humans , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Quetiapine Fumarate/administration & dosage , Quetiapine Fumarate/analysis , Quetiapine Fumarate/pharmacokinetics , Reproducibility of Results , Tandem Mass Spectrometry/methods , Blood Chemical Analysis/methods , Healthy Volunteers
11.
Endokrynol Pol ; 74(2): 203-210, 2023.
Article En | MEDLINE | ID: mdl-37155302

INTRODUCTION: The Martin (MF) and Sampson (SF) formulas have shown greater accuracy for low-density lipoprotein cholesterol (LDL-C) < 70 mg/dL compared to the Friedewald formula (FF); however, some disagreement is maintained. Non-high-density lipoprotein cholesterol (non-HDL-C) and apolipoprotein B (ApoB) are alternatives to assessing cardiovascular risk in patients with very low LDL-C. The objective was to evaluate the accuracy of FF, MF, and SF formulas to estimate LDL-C < 70 mg/dL vs. directly measured LDL-C (LDLd-C) and to compare non-HDL-C and Apo-B levels between the groups of patients with concordant vs. discordant LDL-C. MATERIAL AND METHODS: This was a prospective clinical study with measurements of lipid profile and LDLd-C in 214 patients with triglycerides < 400 mg/dL. For each formula, the estimated LDL-C was compared with the LDLd-C, and the correlation, the median difference, and the discordance rate were evaluated. Non-HDL-C and Apo-B levels were compared between the groups with concordant and discordant LDL-C. RESULTS: The estimated LDL-C was < 70 mg/dL in 130 (60.7%) patients by FF, 109 (50.9%) by MF, and 113 (52.8%) by SF. The strongest correlation was found between LDLd-C and Sampson estimated LDL-C (LDLs-C) (R2 = 0.778), followed by Friedewald-estimated LDL-C (LDLf-C) (R2 = 0.680) and Martin estimated LDL-C (LDLm-C) (R2 = 0.652). Estimated LDL-C < 70 mg/dL was lower than LDLd-C, with the largest median absolute difference (25-75th) of -15 (-19 to -10) with FF. For estimated LDL-C < 70 mg/dL, the discordant rate was 43.8%, 38.1%, and 35.1%, reaching for 62.3%, 50.9%, and 50% when LDL-C < 55 mg/dL by FF, SF, and MF, respectively. Patients in the discordant group presented significantly higher levels of non-HDL-C and ApoB for all 3 formulas (p < 0.001). CONCLUSION: FF was the most inaccurate formula to estimate very low LDL-C. Despite MF and SF showing better results, their frequency in underestimating LDL-C was still considerable. In patients with falsely low estimated LDL-C, apoB and non-HDL-C were significantly higher, reflecting its true high atherogenic burden.


Algorithms , Blood Chemical Analysis , Cholesterol, LDL , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Cholesterol, LDL/blood , Reproducibility of Results , Apolipoproteins/blood , Triglycerides/blood , Humans , Male , Female , Middle Aged
12.
Clin Lab ; 69(4)2023 Apr 01.
Article En | MEDLINE | ID: mdl-37057939

BACKGROUND: Low-density lipoprotein cholesterol (LDL-C) can contribute to atherosclerosis if it is oxidized within the walls of arteries. Therefore, LDL-C plays an important role in cardiovascular disease risk assessment and prevention. The current study aims to evaluate the validity of Friedewald's formula in the Taiwanese population. METHODS: In this analytical cross-sectional study, a data set containing 31,729 results was used and lipid profiles of all samples were measured using the Beckman Coulter AU680 clinical chemistry analyzer. This study was conducted from September 2016 to August 2019. RESULTS: The agreement between the direct and calculated LDL-C was significant with Pearson's correlation coefficient (r) of 0.904 (p < 0.001). Mean LDL-C levels were 99.3 ± 32.8 mg/dL and 95.3 ± 37.6 mg/dL for direct and calculated LDC-C, respectively. CONCLUSIONS: Good agreement was observed between direct and calculated LDC-C. Therefore, it can be concluded that Friedewald's formula is applicable in LDL-C estimation when the direct method is not affordable.


Blood Chemical Analysis , Cardiovascular Diseases , Cholesterol, LDL , Humans , Cholesterol, LDL/blood , Cross-Sectional Studies , Triglycerides/blood , East Asian People , Taiwan , Cardiovascular Diseases/blood , Heart Disease Risk Factors , Atherosclerosis/blood , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/methods
13.
J Biophotonics ; 16(6): e202200377, 2023 06.
Article En | MEDLINE | ID: mdl-36906736

Analysis of blood species is an extremely important part in customs inspection, forensic investigation, wildlife protection and other fields. In this study, a classification method based on Siamese-like neural network (SNN) for interspecies blood (22 species) was proposed to measure Raman Spectra similarity. The average accuracy was above 99.20% in the test set of spectra (known species) that did not appear in the training set. This model could detect species not represented in the dataset underlying the model. After adding new species to the training set, we can update the training based on the original model without retraining the model from scratch. For species with lower accuracy, SNN model can be trained intensively in the form of enriched training data for that species. A single model can achieve both multiple-classification and binary classification functions. Moreover, SNN showed higher accuracy rates when trained with smaller datasets compared to other methods.


Blood Chemical Analysis , Neural Networks, Computer , Blood Chemical Analysis/methods
14.
J Nanobiotechnology ; 21(1): 104, 2023 Mar 24.
Article En | MEDLINE | ID: mdl-36964516

Non-small cell lung cancer (NSCLC) is the most common pathological type of LC and ranks as the leading cause of cancer deaths. Circulating exosomes have emerged as a valuable biomarker for the diagnosis of NSCLC, while the performance of current electrochemical assays for exosome detection is constrained by unsatisfactory sensitivity and specificity. Here we integrated a ratiometric biosensor with an OR logic gate to form an assay for surface protein profiling of exosomes from clinical serum samples. By using the specific aptamers for recognition of clinically validated biomarkers (EpCAM and CEA), the assay enabled ultrasensitive detection of trace levels of NSCLC-derived exosomes in complex serum samples (15.1 particles µL-1 within a linear range of 102-108 particles µL-1). The assay outperformed the analysis of six serum biomarkers for the accurate diagnosis, staging, and prognosis of NSCLC, displaying a diagnostic sensitivity of 93.3% even at an early stage (Stage I). The assay provides an advanced tool for exosome quantification and facilitates exosome-based liquid biopsies for cancer management in clinics.


Carcinoma, Non-Small-Cell Lung , Electrochemistry , Exome , Carcinoma, Non-Small-Cell Lung/blood , Carcinoma, Non-Small-Cell Lung/diagnosis , Biosensing Techniques , Limit of Detection , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Humans , Cell Line, Tumor
15.
Biomacromolecules ; 24(2): 766-774, 2023 02 13.
Article En | MEDLINE | ID: mdl-36627763

Heparin, an anionic biomacromolecule, is routinely used as an anticoagulant during medical surgery to prevent blood clot formation and in the treatment of several heart, lung, and circulatory disorders having a higher risk of blood clotting. We herein report supramolecular polymeric nanoassemblies of cationic pyrene-tagged bis-imidazolium amphiphiles for heparin detection with high sensitivity and selectivity in aqueous buffer, plasma, and serum media. The nano-assemblies exhibited cyan-green excimeric emission in aqueous media, and their multivalent array of positive surface charges allowed them to form co-assemblies with heparin, resulting in significantly enhanced emission. This provided a convenient method for heparin detection in buffer at nanomolar concentrations, and most notably, a ratiometric fluorescence response was obtained even in highly competitive 100% human serum and 100% human plasma in a clinically relevant concentration range. Moreover, using the heparin-based luminescent co-assemblies, protamine sulfate, a clinically administered antidote to heparin, was also detected in 100% human serum and 100% human plasma at sub-micromolar concentrations.


Blood Chemical Analysis , Heparin , Protamines , Humans , Anticoagulants/pharmacology , Blood Coagulation , Heparin/analysis , Heparin/pharmacology , Luminescence , Polymers/pharmacology , Protamines/analysis , Protamines/pharmacology , Blood Chemical Analysis/methods , Serum/chemistry , Plasma/chemistry , Buffers
16.
Anal Chem ; 95(5): 3089-3097, 2023 02 07.
Article En | MEDLINE | ID: mdl-36692453

Here, we describe the generation of dynamic vortices in micro-scale cavities at low flow rates. The system utilizes a computer-controlled audio speaker to axially oscillate the inlet tube of the microfluidic system at desired frequencies and amplitudes. The oscillation of the tube induces transiently high flow rates in the system, which facilitates the generation of dynamic vortices inside the cavity. The size of the vortices can be modulated by varying the tube oscillation frequency or amplitude. The vortices can be generated in single or serial cavities and in a wide range of cavity sizes. We demonstrate the suitability of the tube oscillation mechanism for the pulsed injection of water-based solutions or whole blood into the cavity. The injection rate can be controlled by the oscillation characteristics of the tube, enabling the injection of liquids at ultralow flow rates. The dynamic vortices facilitate the rapid mixing of the injected liquid with the main flow. The controllability and versatility of this technology allow for the development of programmable inertial microfluidic systems for performing multistep biological assays.


Blood Chemical Analysis , Microfluidics , Microfluidics/methods , Blood Chemical Analysis/methods
18.
PLoS One ; 17(2): e0263738, 2022.
Article En | MEDLINE | ID: mdl-35130295

Point-of-Care (POC) testing for biomarker detection demands techniques that are easy to use, readily available, low-cost, and with rapid response times. This paper describes the development of a fully open-source, modular, wireless, battery-powered, smartphone-controlled, low-cost potentiostat capable of conducting electrochemical impedance spectroscopy for the electrochemical detection of the S100B protein captured in an ANTI-S100B functionalized thin-film gold interdigitated electrode platform to support traumatic brain injury diagnosis and treatment. EIS results from the developed potentiostat were validated with a commercial benchtop potentiostat by comparing impedance magnitude and phase values along the EIS frequency range. In addition, an experimental design was performed for detecting S100B in spiked human plasma samples with S100B concentrations of clinical utility, and a calibration curve was found for quantifying S100B detection. No statistically significant differences were found between EIS results from the developed potentiostat and the commercial potentiostat. Statistically significant differences in the changes in charge transfer resistance signal between each tested S100B concentration (p < 0.05) were found, with a limit of detection of 35.73 pg/mL. The modularity of the proposed potentiostat allows easier component changes according to the application demands in power, frequency excitation ranges, wireless communication protocol, signal amplification and transduction, precision, and sampling frequency of ADC, among others, when compared to state-of-the-art open-source EIS potentiostats. In addition, the use of minimal, easy acquirable open-source hardware and software, high-level filtering, accurate ADC, Fast Fourier Transform with low spectral leakage, wireless communication, and the simple user interface provides a framework for facilitating EIS analysis and developing new affordable instrumentation for POC biosensors integrated systems.


Biosensing Techniques , Brain Injuries, Traumatic/diagnosis , Dielectric Spectroscopy , Point-of-Care Systems , S100 Calcium Binding Protein beta Subunit/blood , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/methods , Brain Injuries, Traumatic/blood , Brain Injuries, Traumatic/pathology , Colombia , Dielectric Spectroscopy/instrumentation , Dielectric Spectroscopy/methods , Electric Impedance , Electrochemical Techniques/instrumentation , Electrodes , Gold/chemistry , Humans , Potentiometry/instrumentation , Potentiometry/methods , S100 Calcium Binding Protein beta Subunit/analysis , Software , Trauma Severity Indices , Wireless Technology/instrumentation
19.
Environ Toxicol Pharmacol ; 90: 103813, 2022 Feb.
Article En | MEDLINE | ID: mdl-35033683

Phthalates are endocrine disrupting compounds that have been found in outdoor and indoor air. However, little is known about their inhalatory absorption. Although measurement of urinary metabolites is the current standard, complex and convergent metabolism of phthalates poses the necessity for alternative methodologies such as the quantitation of parental compounds in plasma. We determined the inhalatory absorption of Diisobutyl phthalate (DiBP) using a novel method based on a thermal desorption probe (TSP)-gas chromatography-mass spectrometry developed for the detection and quantitation of nine phthalate diesters in blood plasma, which fulfilled the acceptance criteria suggested by FDA guidelines regarding specificity, matrix effect, recovery, linearity, sensitivity, accuracy, and precision. After inhalation, plasma concentration of DiBP exhibited two peaks, suggesting a first, rapid absorption event, followed by a second, delayed one and a first order elimination stage. Half-life was calculated as 62 min and bioavailability, compared to IV route, was 15%.


Dibutyl Phthalate/analogs & derivatives , Inhalation Exposure/analysis , Phthalic Acids/analysis , Animals , Blood Chemical Analysis/methods , Dibutyl Phthalate/toxicity , Gas Chromatography-Mass Spectrometry , Male , Rats , Rats, Wistar , Toxicokinetics
20.
Anal Bioanal Chem ; 414(4): 1503-1512, 2022 Feb.
Article En | MEDLINE | ID: mdl-35024915

Food contact materials (FCM) polyethylene terephthalate (PET) and polybutylene terephthalate (PBT) used extensively in food packaging may contain cyclic oligomers which may migrate into food and thus cause toxic effects on human health. A simple, fast, and sensitive ultra-high-performance liquid chromatography method quadrupole time-of-flight mass spectrometer was developed for the analysis of 7 cyclic oligomers in post-mortem blood samples. The targeted analytes were separated on a Waters BEH C18 (150 × 2.1 mm, 1.7 µm) analytical column by gradient elution. Calibration curves were constructed based on standard solutions and blood samples and Student's t-test was applied to evaluate the matrix effect. The LODs ranged from 1.7 to 16.7 µg mL-1, while the method accuracy was assessed by recovery experiments and resulting within the range 84.2-114.6%. Such an analytical method for the determination of PET and PBT cyclic oligomers in biological samples is reported for the first time. The developed methodology allows the determination of these oligomers in blood providing a useful analytical tool to assess the exposure and thus the potential hazard and health risks associated with these non-intentionally added substances (NIAS) from PET and PBT FCM through food consumption. The method was validated and successfully applied to the analysis of 34 post-mortem whole blood samples. Polyethylene terephthalate trimer was detected in four of them, for the first time in literature.


Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid/methods , Mass Spectrometry/methods , Polyesters/analysis , Polyethylene Terephthalates/analysis , Aged , Food Packaging , Humans , Limit of Detection , Liquid-Liquid Extraction , Polyesters/chemistry , Polyethylene Terephthalates/chemistry , Reproducibility of Results , Sensitivity and Specificity
...