Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.946
Filtrar
1.
Can Vet J ; 65(8): 763-768, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39091474

RESUMEN

A 5-month-old Pembroke Welsh corgi dog was presented with a 3-month history of lethargy, inappetence, polyuria/polydipsia, and neurological signs. A diagnosis of a complex multiple intrahepatic portosystemic shunt (IHPSS) configuration was obtained by computed tomography angiogram, abdominal ultrasonography, and perioperative fluoroscopic angiography. The IHPSS was successfully attenuated by shunt embolization with a vascular plug, using a direct percutaneous hepatic approach under ultrasonographic and fluoroscopic guidance. Long-term (4 y) follow-up revealed resolution of all clinical signs. The owner elected to continue dietary modification and lactulose treatment indefinitely and the outcome was considered good. Key clinical message: Direct percutaneous hepatic approach could be considered for IHPSS attenuation in select cases where traditional transvenous approach access is considered challenging.


Atténuation percutanée trans-hépatique guidée par échographie et fluoroscopie d'un shunt porto-systémique intrahépatique canin complexe à l'aide d'un bouchon vasculaireUn chien Pembroke Welsh corgi âgé de 5 mois a été présenté avec des antécédents de léthargie, d'inappétence, de polyurie/polydipsie et de signes neurologiques depuis 3 mois. Un diagnostic de configuration complexe de shunt porto-systémique intrahépatique multiple (IHPSS) a été obtenu par angiographie par tomodensitométrie, échographie abdominale et angiographie fluoroscopique périopératoire. L'IHPSS a été atténué avec succès par embolisation du shunt avec un bouchon vasculaire, en utilisant une approche hépatique percutanée directe sous guidage échographique et fluoroscopique. Un suivi à long terme (4 ans) a révélé une résolution de tous les signes cliniques. Le propriétaire a choisi de poursuivre indéfiniment la modification du régime alimentaire et le traitement au lactulose et le résultat a été considéré comme bon.Message clinique clé :Une approche hépatique percutanée directe pourrait être envisagée pour l'atténuation de l'IHPSS dans certains cas où l'accès par voie trans-veineuse traditionnelle est considéré comme difficile.(Traduit par Dr Serge Messier).


Asunto(s)
Enfermedades de los Perros , Embolización Terapéutica , Perros , Animales , Enfermedades de los Perros/cirugía , Enfermedades de los Perros/diagnóstico por imagen , Fluoroscopía/veterinaria , Embolización Terapéutica/veterinaria , Embolización Terapéutica/métodos , Masculino , Ultrasonografía/veterinaria , Femenino
2.
Radiographics ; 44(8): e230197, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39088363

RESUMEN

Fluoroscopy is an advanced medical imaging modality that utilizes x-rays to acquire real-time images throughout a medical examination. It is commonly used in various procedures such as in interventional radiology, cardiac catheterization, and gastrointestinal and genitourinary studies. While fluoroscopy is a valuable diagnostic and therapeutic tool, it exposes patients and medical staff to ionizing radiation, which carries health risks. A radiation dose summary page is a report generated by the fluoroscope that displays important information about the procedure. It provides an overview of the radiation doses administered during a fluoroscopic procedure, as well as certain technical parameters used during the irradiation events. The contents of a radiation dose summary page may vary depending on the make and model of the fluoroscope but some common elements include the cumulative reference air kerma, which serves as a surrogate of radiation dose delivered to the patient, and the dose-area product, which takes account of the x-ray beam area and is a measure of the total amount of energy imparted on the patient. Other imaging acquisition parameters may be also included in the dose summary page, including tube voltage, tube current, pulse width, pulse rate, spectral filters, primary and secondary angles, and source-to-image distance. The radiation dose summary page for fluoroscopy is a useful tool for physicians, technologists, and medical physicists, allowing them to comprehend the technical details of a fluoroscopically guided procedure. ©RSNA, 2024.


Asunto(s)
Dosis de Radiación , Radiografía Intervencional , Fluoroscopía , Humanos , Radiografía Intervencional/métodos , Protección Radiológica/métodos
3.
Best Pract Res Clin Gastroenterol ; 70: 101928, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39053981

RESUMEN

Spontaneous, iatrogenic or surgical perforation of the whole gastrointestinal wall can lead to serious complications, resulting in increased morbidity and mortality. Optimal patient management requires early clinical appraisal and prompt imaging evaluation. Both radiologists and referring clinicians should recognize the importance of choosing the ideal imaging modality and the usefulness of oral and rectal contrast medium. Surgeons and radiologists should be familiar with CT and fluoroscopy findings of the normal and pathologic anatomy after esophageal, stomach or colon surgery. Specifically, they should be able to differentiate innocuous from clinically-relevant, life-threatening postoperative complications to guide appropriate treatment. Advantages of esophagram, CT-esophagram, CT after rectal contrast enema and other imaging modalities are discussed.


Asunto(s)
Perforación Intestinal , Humanos , Perforación Intestinal/diagnóstico por imagen , Perforación Intestinal/etiología , Perforación Intestinal/cirugía , Tomografía Computarizada por Rayos X , Medios de Contraste/administración & dosificación , Fluoroscopía , Perforación del Esófago/diagnóstico por imagen , Perforación del Esófago/etiología
4.
Sci Rep ; 14(1): 16907, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39043758

RESUMEN

Dual-position oblique lumbar interbody fusion with fluoroscopy (D-OLIF) requires repositioning the patient to a prone position for pedicle screw insertion. Recently, single-position surgery with navigation has been introduced. However, there are concerns regarding pedicle screw accuracy and achieving appropriate sagittal balance in single-position OLIF with navigation (S-OLIF). The purpose of this study is to evaluate the clinical and radiological outcomes of S-OLIF compared to D-OLIF. A retrospective analysis was conducted on 102 patients who underwent single-level OLIF at a single institution. The patients were divided into two groups: 55 in the S-OLIF group and 47 in the D-OLIF group. The numeric rating scale for back and leg, Oswestry disability index, and walking distance improvements showed no significant difference. However, the EuroQol 5-dimension 5-level index showed higher improvement in the S-OLIF (P = 0.029). The segmental lordosis, lumbar lordosis, and C7 sagittal vertical axis showed no significant difference. S-OLIF had significantly fewer cases of pedicle screw malposition (P = 0.045). Additionally, the surgery time was shorter in the S-OLIF (P = 0.002). In conclusion, S-OLIF exhibited clinical and radiological outcomes comparable to D-OLIF, with the added advantages of reduced surgery time and enhanced accuracy in pedicle screw placement.


Asunto(s)
Vértebras Lumbares , Tornillos Pediculares , Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Femenino , Masculino , Fluoroscopía/métodos , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Cirugía Asistida por Computador/métodos
5.
BMC Musculoskelet Disord ; 25(1): 572, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39044221

RESUMEN

BACKGROUND: Previous studies have shown that surgical technique errors especially the wrong bone tunnel position are the primary reason for the failure of anterior cruciate ligament (ACL) reconstruction. In this study, we aimed to compare the femoral tunnel position and impact on knee function during the ACL reconstruction using measuring combined with fluoroscopy method and bony marker method for femoral tunnel localization. METHODS: A retrospective cohort study of patients undergoing ACL reconstruction using the bony marker method or measuring combined with fluoroscopy for femoral tunnel localization was conducted between January 2015 and January 2020. A second arthroscopic exploration was performed more than 1 year after surgery. Data regarding patient demographics, the femoral tunnel position, results of the Lysholm score, the International Knee Documentation Committee (IKDC) score, KT-1000 side-to-side difference, pivot shift grade, and Lachman grade of the knee were collected. RESULTS: A total of 119 patients were included in the final cohort. Of these, 42 cases were in the traditional method group, and 77 cases were in the measuring method group. The good tunnel position rate was 26.2% in the traditional method group and 81.8% in the measuring method group (p < 0.001). At the final follow-up, the Lysholm and IKDC scores were significantly greater in the measuring method group than the traditional method group (IKDC: 84.9 ± 8.4 vs. 79.6 ± 6.4, p = 0.0005; Lysholm: 88.8 ± 6.4 vs. 81.6 ± 6.4, p < 0.001). Lachman and pivot shift grades were significantly greater in the measuring method group (p = 0.01, p = 0008). The results of KT-1000 side-to-side differences were significantly better in the measuring method group compared with those in the traditional method group (p < 0.001). CONCLUSIONS: The combination of the measuring method and intraoperative fluoroscopy resulted in a concentrated tunnel position on the femoral side, a high rate of functional success, improved knee stability, and a low risk of tunnel deviation. This approach is particularly suitable for surgeons new to ACL reconstructive surgery.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Fémur , Articulación de la Rodilla , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Estudios Retrospectivos , Femenino , Fluoroscopía/métodos , Masculino , Adulto , Fémur/cirugía , Fémur/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Adulto Joven , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Artroscopía/métodos , Adolescente , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/diagnóstico por imagen , Resultado del Tratamiento , Rango del Movimiento Articular
6.
J Robot Surg ; 18(1): 282, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38972955

RESUMEN

Eighty consecutive complex spinal robotic cases utilizing intraoperative 3D CT imaging (E3D, Group 2) were compared to 80 age-matched controls using the Excelsius robot alone with C-arm Fluoroscopic registration (Robot Only, Group 1). The demographics between the two groups were similar-severity of deformity, ASA Score for general anesthesia, patient age, gender, number of spinal levels instrumented, number of patients with prior spinal surgery, and amount of neurologic compression. The intraoperative CT scanning added several objective factors improving patient safety. There were significantly fewer complications in the E3D group with only 3 of 80 (4%) patients requiring a return to the operating room compared to 11 of 80 (14%) patients in the Robot Only Group requiring repeat surgery for implant related problems (Chi squared analysis = 5.00, p = 0.025). There was a significant reduction the amount of fluoroscopy time in the E3D Group (36 s, range 4-102 s) compared to Robot only group (51 s, range 15-160 s) (p = 0.0001). There was also shorter mean operative time in the E3D group (257 ± 59.5 min) compared to the robot only group (306 ± 73.8 min) due to much faster registration time (45 s). A longer registration time was required in the Robot only group to register each vertebral level with AP and Lateral fluoroscopy shots. The estimated blood loss was also significantly lower in Group 2 (mean 345 ± 225 ml) vs Group 1 (474 ± 397 ml) (p = 0.012). The mean hospital length of stay was also significantly shorter for Group 2 (3.77 ± 1.86 days) compared to Group 1 (5.16 ± 3.40) (p = 0.022). There was no significant difference in the number of interbody implants nor corrective osteotomies in both groups-Robot only 52 cases vs. 42 cases in E3D group.Level of evidence: IV, Retrospective review.


Asunto(s)
Imagenología Tridimensional , Tempo Operativo , Procedimientos Quirúrgicos Robotizados , Fusión Vertebral , Tomografía Computarizada por Rayos X , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Persona de Mediana Edad , Adulto , Imagenología Tridimensional/métodos , Anciano , Fluoroscopía/métodos , Tomografía Computarizada por Rayos X/métodos , Cirugía Asistida por Computador/métodos , Adulto Joven , Anciano de 80 o más Años , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología
8.
J Cardiothorac Surg ; 19(1): 437, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-38997733

RESUMEN

OBJECTIVES: This study aimed at exploring how using different kinds of sheaths will affect the very first ablation procedure of apprentices. METHODS: 15 patients with paroxysmal atrial fibrillation were randomized to used fixed-curve, conventional steerable or visualized steerable sheath, and received complete isolation of pulmonary veins. All ablations were the very first procedure performed by 15 ablation apprentices. The use of fluoroscopy and catheter stability during the PVI were analyzed. RESULTS: Procedure duration was much longer in the fixed-curve group (116.8 ± 27 vs. 62.2 ± 17 vs. 60.4 ± 17, p < 0.001). X-ray exposure was lowest with visualized sheath (17.6 ± 5 vs. 18.6 ± 6 vs. 5.2 ± 6, p < 0.001). CF SD differed significantly, especially at the anterior aspect of LSPV (7.90 ± 2.90 vs. 5.04 ± 2.18 vs. 4.52 ± 2.40, p < 0.001) and posterior aspect of RSPV (6.84 ± 2.79 vs. 3.42 ± 2.04 vs. 3.50 ± 2.30, p < 0.001) in the fixed-curve group. Impedance drop was significantly smaller in the fixed-curve group at the anterior aspect of LSPV (8.74 ± 3.02 vs. 11.49 ± 5.48 vs. 12.57 ± 5.96, p = 0.005). CONCLUSION: Even for the very first ablation procedure of an ablation apprentice, the use of steerable sheaths will significantly reduce the procedure duration and improve the catheter stability, but only visualized steerable sheath can reduce fluoroscopic time.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Fluoroscopía , Resultado del Tratamiento , Adulto
9.
Langenbecks Arch Surg ; 409(1): 207, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38976070

RESUMEN

OBJECTIVE: This study aimed to compare the results of retrograde intrarenal surgery (RIRS) and mini-percutaneous nephrolithotomy (mini-PCNL) for the treatment of 1-2 cm kidney stones in pediatric patients. METHODS: The records of patients under the age of 18 years who were diagnosed with unilateral 1-2 cm kidney stones for the first time and underwent endoscopic surgery between February 2008 and April 2022 were retrospectively examined. The patients were divided into two groups: mini-PCNL and RIRS surgery. Parameters such as age, gender, number of stones, side, size and localization were examined. The main endpoint of the study was to compare stone-free rates (SFR) one month after both surgeries. Surgery and fluoroscopy times, postoperative hospital stay, hemoglobin decrease and complication rates were compared between the groups. SFR was evaluated one month after surgery by direct urinary system radiography and USG or CT. RESULTS: A total of 58 patients were included in the study. There were 35 patients in the mini-PCNL group and 23 patients in the RIRS group. Table 1 shows the demographic and clinical characteristics of both groups. There was no significant difference between the groups in terms of age, gender, stone size, location, side and density. Calcium oxalate stones were observed at a higher rate in both groups. Mean fluoroscopy time was higher in the mini-PCNL group (p = 0.001). The mean surgery time was lower in the mini-PCNL group (p = 0.024). The mean hemoglobin decrease was greater in the percutaneous group (p = 0.039). There were no differences between the groups in terms of postoperative hospital stay, complication rates, and SFR one month after surgery. CONCLUSION: Although mini-PCNL seems to be more advantageous in terms of operation time compared to RIRS, it is disadvantageous in terms of average fluoroscopy time, radiation received and average hemoglobin decrease.


Asunto(s)
Cálculos Renales , Nefrolitotomía Percutánea , Humanos , Cálculos Renales/cirugía , Femenino , Masculino , Niño , Estudios Retrospectivos , Nefrolitotomía Percutánea/métodos , Nefrolitotomía Percutánea/efectos adversos , Adolescente , Resultado del Tratamiento , Preescolar , Tempo Operativo , Tiempo de Internación , Fluoroscopía
10.
Agri ; 36(3): 202-205, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38985106

RESUMEN

Osteitis pubis (OP) is a rare, inflammatory disorder that affects the pubic bone, symphysis, and adjacent structures. OP is reported after urological and gynecological surgeries and documented in athletes. OP is a self-limiting condition, but sometimes symptoms may persist for a long time. Conservative modalities are generally able to treat OP. Here we report a patient treated with a steroid injection under fluoroscopy guidance. A 63-year-old male patient developed pelvic pain after prostate surgery, and the pain was intractable to non-steroidal anti-inflammatory drugs. He underwent a steroid injection under fluoroscopy, and his pain affecting daily living activities and walking was eased for three months.


Asunto(s)
Osteítis , Dolor Pélvico , Hueso Púbico , Humanos , Masculino , Persona de Mediana Edad , Fluoroscopía , Osteítis/tratamiento farmacológico , Dolor Pélvico/etiología , Dolor Pélvico/tratamiento farmacológico , Diagnóstico Diferencial , Esteroides/administración & dosificación , Esteroides/uso terapéutico
11.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(7): 836-841, 2024 Jul 15.
Artículo en Chino | MEDLINE | ID: mdl-39013821

RESUMEN

Objective: To introduce a new fluoroscopic method for assessing the quality of medial and lateral joint surface reduction during internal fixation of patellar fractures and to summarize the clinical outcomes of patients treated using this method. Methods: A retrospective analysis was conducted on the clinical data of 52 patients with patellar fractures treated between January 2018 and January 2022 who met the inclusion criteria. There were 27 male and 25 female patients, aged 21-75 years, with an average age of 62 years. The types of patellar fractures included 9 transverse fractures, 37 comminuted fractures, and 6 longitudinal fractures. According to the AO/Orthopaedic Trauma Association (AO-OTA)-2018 fracture classification, there were 21 cases of type 34A, 6 cases of type 34B, and 25 cases of type 34C. The time from injury to operation ranged from 1 to 5 days, with an average of 2.3 days. Treatments included internal fixation with hollow screws or hollow screw tension bands, with or without anchor repair. During operation, the medial and lateral joint surfaces of the patella were observed using the tangential fluoroscopic method to assess the smoothness of reduction of the median ridge, lateral joint surface, medial joint surface, and lateral joint edge. Patients were followed up regularly, and X-ray films were taken to observe fracture healing. Knee joint range of motion, Böstman score, and Lysholm score were used to evaluate functional recovery. Results: The tangential fluoroscopic method for the medial and lateral joint surfaces of the patella during operation showed satisfactory reduction of the joint surfaces and good positioning of the implants. All patients were followed up 12-16 months, with an average of 13.4 months. During the follow-up, fracture displacement occurred in 1 case and titanium cable breakage in 1 case. All patella fractures healed successfully, with a healing time of 8-16 weeks (mean, 11.4 weeks). At last follow-up, knee joint range of motion ranged from 120° to 140°, with an average of 136°. The Böstman score ranged from 20 to 30, with an average of 28, yielding excellent results in 45 cases and good results in 7 cases. The Lysholm score ranged from 88 to 100, with an average of 93, yielding excellent results in 40 cases and good results in 12 cases. Conclusion: The intraoperative application of the tangential fluoroscopic method for the medial and lateral joint surfaces of the patella can quickly determine the fluoroscopic plane of the patella, accurately assess the quality of fracture reduction and the position of internal fixator, thereby improving effectiveness.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Humanos , Rótula/lesiones , Rótula/cirugía , Femenino , Masculino , Fijación Interna de Fracturas/métodos , Adulto , Fluoroscopía/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Anciano , Adulto Joven , Resultado del Tratamiento , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Fracturas Conminutas/cirugía , Fracturas Conminutas/diagnóstico por imagen , Fractura de Rótula
12.
J Pak Med Assoc ; 74(7): 1358-1360, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39028071

RESUMEN

Residual intravenous foreign bodies following hand trauma are relatively rare; only a few previous reports of this situation are available. It has been reported that foreign bodies often migrate to the heart and atrium dextrum. Herein, we report a recent case of needle breakage in the dorsal vein of the hand that was removed with lignification using an intraoperative C-arm fluoroscopy machine and tape tourniquet to avoid proximal movement during removal. The mandate should be to remove within the capacity allowed so that rare cases and terrible complications can be avoided. The case was seen at The Yanji City, Jilin Province, China at the Yanbian University Hospital emergency at February 20, 2023.


Asunto(s)
Cuerpos Extraños , Agujas , Humanos , Agujas/efectos adversos , Cuerpos Extraños/cirugía , Cuerpos Extraños/diagnóstico por imagen , Masculino , Traumatismos de la Mano/cirugía , Fluoroscopía , Venas/lesiones , Venas/diagnóstico por imagen , Venas/cirugía , Administración Intravenosa
13.
J Biomech Eng ; 146(11)2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38959087

RESUMEN

Goals of knee replacement surgery are to restore function and maximize implant longevity. To determine how well these goals are satisfied, tibial femoral kinematics and tibial contact kinematics are of interest. Tibiofemoral kinematics, which characterize function, is movement between the tibia and femur whereas tibial contact kinematics, which is relevant to implant wear, is movement of the location of contact by the femoral implant on the tibial articular surface. The purposes of this review article are to describe and critique relevant methods to guide correct implementation. For tibiofemoral kinematics, methods are categorized as those which determine (1) relative planar motions and (2) relative three-dimensional (3D) motions. Planar motions are determined by first finding anterior-posterior (A-P) positions of each femoral condyle relative to the tibia and tracking these positions during flexion. Of the lowest point (LP) and flexion facet center (FFC) methods, which are common, the lowest point method is preferred and the reasoning is explained. 3D motions are determined using the joint coordinate system (JCS) of Grood and Suntay. Previous applications of this JCS have resulted in motions which are largely in error due to "kinematic crosstalk." Requirements for minimizing kinematic crosstalk are outlined followed by an example, which demonstrates the method for identifying a JCS that minimizes kinematic crosstalk. Although kinematic crosstalk can be minimized, the need for a JCS to determine 3D motions is questionable based on anatomical constraints, which limit varus-valgus rotation and compression-distraction translation. Methods for analyzing tibial contact kinematics are summarized and validation of methods discussed.


Asunto(s)
Fémur , Tibia , Tibia/fisiología , Tibia/diagnóstico por imagen , Fenómenos Biomecánicos , Humanos , Fluoroscopía , Fémur/fisiología , Fémur/diagnóstico por imagen , Fenómenos Mecánicos , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/diagnóstico por imagen
14.
Syst Rev ; 13(1): 170, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970142

RESUMEN

BACKGROUND: As an emerging technology in robot-assisted (RA) surgery, the potential benefits of its application in transforaminal lumbar interbody fusion (TLIF) lack substantial support from current evidence. OBJECTIVE: We aimed to investigate whether the RA TLIF is superior to FG TLIF in the treatment of lumbar degenerative disease. METHODS: We systematically reviewed studies comparing RA versus FG TLIF for lumbar degenerative diseases through July 2022 by searching PubMed, Embase, Web of Science, CINAHL (EBSCO), Chinese National Knowledge Infrastructure (CNKI), WanFang, VIP, and the Cochrane Library, as well as the references of published review articles. Both cohort studies (CSs) and randomized controlled trials (RCTs) were included. Evaluation criteria included the accuracy of percutaneous pedicle screw placement, proximal facet joint violation (FJV), radiation exposure, duration of surgery, estimated blood loss (EBL), and surgical revision. Methodological quality was assessed using the Cochrane risk of bias and ROBINS-I Tool. Random-effects models were used, and the standardized mean difference (SMD) was employed as the effect measure. We conducted subgroup analyses based on surgical type, the specific robot system used, and the study design. Two investigators independently screened abstracts and full-text articles, and the certainty of evidence was graded using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. RESULTS: Our search identified 539 articles, of which 21 met the inclusion criteria for quantitative analysis. Meta-analysis revealed that RA had 1.03-folds higher "clinically acceptable" accuracy than FG (RR: 1.0382, 95% CI: 1.0273-1.0493). And RA had 1.12-folds higher "perfect" accuracy than FG group (RR: 1.1167, 95% CI: 1.0726-1.1626). In the case of proximal FJV, our results indicate a 74% reduction in occurrences for patients undergoing RA pedicle screw placement compared to those in the FG group (RR: 0.2606, 95%CI: 0.2063- 0.3293). Seventeen CSs and two RCTs reported the duration of time. The results of CSs suggest that there is no significant difference between RA and FG group (SMD: 0.1111, 95%CI: -0.391-0.6131), but the results of RCTs suggest that the patients who underwent RA-TLIF need more surgery time than FG (SMD: 3.7213, 95%CI: 3.0756-4.3669). Sixteen CSs and two RCTs reported the EBL. The results suggest that the patients who underwent RA pedicle screw placement had fewer EBL than FG group (CSs: SMD: -1.9151, 95%CI: -3.1265-0.7036, RCTs: SMD: -5.9010, 95%CI: -8.7238-3.0782). For radiation exposure, the results of CSs suggest that there is no significant difference in radiation time between RA and FG group (SMD: -0.5256, 95%CI: -1.4357-0.3845), but the patients who underwent RA pedicle screw placement had fewer radiation dose than FG group (SMD: -2.2682, 95%CI: -3.1953-1.3411). And four CSs and one RCT reported the number of revision case. The results of CSs suggest that there is no significant difference in the number of revision case between RA and FG group (RR: 0.4087,95% CI 0.1592-1.0495). Our findings are limited by the residual heterogeneity of the included studies, which may limit the interpretation of the results. CONCLUSION: In TLIF, RA technology exhibits enhanced precision in pedicle screw placement when compared to FG methods. This accuracy contributes to advantages such as the protection of adjacent facet joints and reductions in intraoperative radiation dosage and blood loss. However, the longer preoperative preparation time associated with RA procedures results in comparable surgical duration and radiation time to FG techniques. Presently, FG screw placement remains the predominant approach, with clinical surgeons possessing greater proficiency in its application. Consequently, the integration of RA into TLIF surgery may not be considered the optimal choice. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42023441600.


Asunto(s)
Degeneración del Disco Intervertebral , Vértebras Lumbares , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Robotizados , Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Vértebras Lumbares/cirugía , Fluoroscopía/métodos , Degeneración del Disco Intervertebral/cirugía , Tornillos Pediculares , Tempo Operativo , Estudios de Cohortes
15.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38949665

RESUMEN

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Fluoroscopía/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Prótesis de Cadera , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Cirugía Asistida por Computador/métodos
16.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-39082717

RESUMEN

AIMS: Atrial fibrillation (AF) ablation and left atrial appendage occlusion (LAAO) are increasingly performed as individual procedures. Pulsed field ablation (PFA) has significantly reduced procedure duration and may be advantageous for the combined approach. METHODS AND RESULTS: We have launched a programme for simultaneous AF ablation using PFA and LAAO for patients qualifying for both treatments and excluding those with a complex anatomy. We compare procedure duration and fluoroscopy time against individual procedures (either AF ablation or LAAO alone), all performed by the same operators and using consistent technologies. We performed the combined procedure in 10 patients (50% males; median age 70 years) and excluded 2 patients (17%) because of a complex left atrial appendage anatomy. No death, stroke, or major bleeding events, including pericardial effusion, occurred. For single-procedure comparison, 207 AF ablation procedures and 61 LAAO procedures were available. The total median procedure duration was 79 min (range 60-125) for the combined procedure, 71 min (25-241) for individual AF ablation (51 min without and 78 min with 3-dimensional electroanatomic mapping), and 47 min (15-162) for individual LAAO. The respective fluoroscopy times were 21 (15-26), 15 (5-44), and 10 (3-50) min. For the combined procedure, femoral vein access to last PFA application lasted 49 min (34-93) and LAAO added 20 min (15-37). CONCLUSION: Simultaneous PFA-based AF ablation and LAAO in carefully selected patients is feasible and safe and can be executed within a short overall procedure duration.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Tempo Operativo , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Ablación por Catéter/métodos , Resultado del Tratamiento , Persona de Mediana Edad , Factores de Tiempo , Técnicas Electrofisiológicas Cardíacas , Fluoroscopía , Anciano de 80 o más Años
17.
Sci Rep ; 14(1): 16332, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009806

RESUMEN

Pulmonary vein isolation (PVI) stands as a widely practiced cardiac ablation procedure on a global scale, conventionally guided by fluoroscopy. The concurrent application of electroanatomical mapping systems (EAMS) and intracardiac echocardiography offers a means to curtail radiation exposure. This study aimed to compare procedural outcomes between conventional and our initial zero-fluoroscopy cases in patients with paroxysmal or persistent atrial fibrillation (AF), undergoing point-by-point PVI. Our prospective observational study included 100 consecutive patients with AF who underwent point-by-point radiofrequency PVI. The standard technique was used in the first 50 cases (Standard group), while the fluoroless technique was used in the subsequent 50 patients (Zero group). The zero-fluoroscopy approach exhibited significantly shorter procedural time (59.6 ± 10.7 min vs. 74.6 ± 13.2 min, p < 0.0001), attributed to a reduced access time (17 [16; 20] min vs. 31 [23; 34.5] min, p < 0.001). Comparable results were found for the number of RF applications, total ablation energy, and left atrial dwelling time. In the Zero group, all procedures were achieved without fluoroscopy, resulting in significantly lower fluoroscopy time (0 [0; 0] sec vs. 132 [100; 160] sec, p < 0.0001) and dose (0 [0; 0] mGy vs. 4.8 [4.1; 8.2] mGy, p < 0.0001). The acute success rate was 100%, with no major complications. Zero-fluoroscopy PVI is feasible, safe, and associated with shorter procedure times compared to the standard approach, even in cases without prior experience in zero-fluoroscopy PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Venas Pulmonares/cirugía , Femenino , Masculino , Fluoroscopía/métodos , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios Prospectivos , Anciano , Resultado del Tratamiento , Ecocardiografía/métodos
19.
Neurosurg Rev ; 47(1): 282, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38904889

RESUMEN

Unstable traumas of the spinopelvic junction, which include displaced U-shaped sacral fractures (Roy-Camille type 2 and type 3) and Tile C vertical shear pelvic ring disruptions, occur in severe traumas patients following high speed traffic accident or fall from a height. These unstable traumas of the spinopelvic junction jeopardize one's ability to stand and to walk by disrupting the biomechanical arches of the pelvis, and may also cause cauda equina syndrome. Historically, such patients were treated with bed rest and could suffer a life-long burden of orthopedic and neurological disability. Since Schildhauer pioneer work back in 2003, triangular spinopelvic fixation, whether it is performed in a percutaneous fashion or by open reduction and internal fixation, allows to realign bone fragments of the spinopelvic junction and to resume walking within three weeks. Nevertheless, such procedure remains highly technical and it not encountered very often, even for spine surgeons working in high-volume level 1 trauma centers. Hence, this visual technical note aims to provide a few tips to guide less experience surgeons to complete this procedure safely.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas , Huesos Pélvicos , Sacro , Fracturas de la Columna Vertebral , Humanos , Sacro/cirugía , Sacro/lesiones , Fijación Interna de Fracturas/métodos , Fluoroscopía/métodos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Fracturas de la Columna Vertebral/cirugía , Ilion/cirugía , Fracturas Óseas/cirugía , Pelvis/cirugía
20.
Int J Med Robot ; 20(3): e2650, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38856120

RESUMEN

BACKGROUND: The purpose of this study was to compare one-year patient reported outcome measures between a novel fluoroscopy-based robotic-assisted (FL-RTHA) system and an existing computerised tomography-based robotic assisted (CT-RTHA) system. METHODS: A review of 85 consecutive FL-RTHA and 125 consecutive CT-RTHA was conducted. Outcomes included one-year post-operative Veterans RAND-12 (VR-12) Physical (PCS)/Mental (MCS), Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function (PS)/Joint replacement, and University of California Los Angeles (UCLA) Activity scores. RESULTS: The FL-RTHA cohort had lower pre-operative VR-12 PCS, HOOS Pain, HOOS-PS, HOOS-JR, and UCLA Activity scores compared with patients in the CT-RTHA cohort. The FL-RTHA cohort reported greater improvements in HOOS-PS scores (-41.54 vs. -36.55; p = 0.028) than the CT-RTHA cohort. Both cohorts experienced similar rates of major post-operative complications, and had similar radiographic outcomes. CONCLUSIONS: Use of the fluoroscopy-based robotic system resulted in greater improvements in HOOS-PS in one-year relative to the CT-based robotic technique.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Fluoroscopía , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Artroplastia de Reemplazo de Cadera/métodos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Retrospectivos , Articulación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA