Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 937
Filtrar
1.
Oper Dent ; 49(5): 540-550, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39135205

RESUMEN

PURPOSE: This study aimed to assess the impact of battery levels in single-peak and multi-peak light-curing units (LCUs) on irradiance, and their effects on glass fiber post push-out bond strength to root dentin and the degree of conversion of dual-cure universal resin cement. METHODS AND MATERIALS: Sixty bovine roots underwent endodontic treatment and were randomly distributed into 6 groups (n=10), formed by combining two LCUs (single-peak and multipeak) and three battery levels (100%, 50%, and 10%). A spectrophotometer measured irradiance (mW/ cm2) and spectral irradiance (mW/cm2/nm). Push-out bond strength (PBS) tests occurred at three root regions (cervical, middle, and apical), with optical and scanning electron microscopy for failure mode analysis. Degree of conversion (DC) was evaluated across the root regions. Data were analyzed using two-way repeated measures ANOVA and the Tukey HSD test. The Fisher exact test verified failure modes (α=0.05). RESULTS: As multipeak LCU battery levels decreased, emitted irradiance also diminished, with notable PBS reductions in the apical thirds. Failure modes were influenced by different conditions, primarily exhibiting mixed modes. Battery levels significantly impacted DC in the multipeak LCU, particularly in the cervical region, while the single-peak LCU exhibited DC reduction at the 10% battery level in the cervical region. CONCLUSIONS: Emitted irradiance, resin cement DC, and glass fiber post bond strength to root dentin may be influenced by varying cordless LCUs and battery levels.


Asunto(s)
Luces de Curación Dental , Vidrio , Técnica de Perno Muñón , Cementos de Resina , Cementos de Resina/química , Bovinos , Técnica de Perno Muñón/instrumentación , Animales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Curación por Luz de Adhesivos Dentales/métodos , Técnicas In Vitro , Dentina
2.
Braz Dent J ; 35: 5746, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045986

RESUMEN

This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Dentina , Vidrio , Técnica de Perno Muñón , Humanos , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Ensayo de Materiales , Propiedades de Superficie , Materiales Dentales/química , Diente no Vital
3.
J Biomed Mater Res B Appl Biomater ; 112(8): e35459, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39082218

RESUMEN

Poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) nanofibers embedded with borate glasses of 45B5 composition doped with Co2+, Cu2+, and Zn2 +(46.1 B2O326.9-X CaO24.4 Na2O2.6 P2O5, X CoO/CuO/ZnO mol % (X = 0-5)) were produced by electrospinning for wound healing applications. Prior to their addition, the glasses exhibited two broad halos typical of a vitreous borate network, which were mainly composed of ring-type metaborate structural units. The particle distribution in the PHBV nanofibers embedded with 45B5 borate bioactive glasses is present in isolated and agglomerated states, being partially coated by a polymeric layer-except for the cobalt-doped glass, which resulted in a successful encapsulation with 100% embedding efficiency. The incorporation of the glasses reduced the PHBV crystallinity degree and its decomposition temperature, as well as its mechanical properties, including Young's modulus, tensile strength, and elongation at break. The neat PHBV fibers and those containing the cobalt-doped glasses demonstrated great cytocompatibility with human keratinocytes (HaCat), as suggested by the high cell viability after 7 days of exposure. Further studies are needed to fully understand the wound healing potential of these fibers, but our results significantly contribute to the area.


Asunto(s)
Vendajes , Boratos , Cobalto , Cobre , Poliésteres , Zinc , Humanos , Cobre/química , Cobalto/química , Poliésteres/química , Boratos/química , Zinc/química , Vidrio/química , Ensayo de Materiales , Cicatrización de Heridas , Nanofibras/química , Línea Celular , Polihidroxibutiratos
4.
ACS Appl Bio Mater ; 7(7): 4642-4653, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38967050

RESUMEN

Titanium-based implants have long been studied and used for applications in bone tissue engineering, thanks to their outstanding mechanical properties and appropriate biocompatibility. However, many implants struggle with osseointegration and attachment and can be vulnerable to the development of infections. In this work, we have developed a composite coating via electrophoretic deposition, which is both bioactive and antibacterial. Mesoporous bioactive glass particles with gentamicin were electrophoretically deposited onto a titanium substrate. In order to validate the hypothesis that the quantity of particles in the coatings is sufficiently high and uniform in each deposition process, an easy-to-use image processing algorithm was designed to minimize human dependence and ensure reproducible results. The addition of loaded mesoporous particles did not affect the good adhesion of the coating to the substrate although roughness was clearly enhanced. After 7 days of immersion, the composite coatings were almost dissolved and released, but phosphate-related compounds started to nucleate at the surface. With a simple and low-cost technique like electrophoretic deposition, and optimized stir and suspension times, we were able to synthesize a hemocompatible coating that significantly improves the antibacterial activity when compared to the bare substrate for both Gram-positive and Gram-negative bacteria.


Asunto(s)
Antibacterianos , Quitosano , Electroforesis , Gentamicinas , Vidrio , Ensayo de Materiales , Nanopartículas , Tamaño de la Partícula , Propiedades de Superficie , Titanio , Gentamicinas/farmacología , Gentamicinas/química , Titanio/química , Titanio/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Vidrio/química , Nanopartículas/química , Quitosano/química , Quitosano/farmacología , Porosidad , Pruebas de Sensibilidad Microbiana , Humanos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Prótesis e Implantes , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología
5.
Dent Mater ; 40(10): 1507-1514, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39048463

RESUMEN

OBJECTIVE: To evaluate experimental dimethacrylate-based materials containing calcium orthophosphates or calcium silicate particles in terms of their optical, mechanical and Ca2+ release behaviour. METHODS: Dicalcium phosphate dihydrate (DCPD), hydroxyapatite (HAp), beta-tricalcium phosphate (ß-TCP) or calcium silicate (CaSi) particles were added to a photocurable BisGMA/TEGDMA resin (1:1 in mols) at a 30 vol% fraction. Materials containing silanized or non-silanized barium glass particles were used as controls. Degree of conversion (DC) at the top and base of 2-mm thick specimens was determined by ATR-FTIR spectroscopy (n = 5). Translucency parameter (TP) and transmittance (%T) were determined using a spectrophotometer (n = 3). Biaxial flexural strength (BFS) and flexural modulus (FM) were determined by biaxial flexural testing after 24 h storage in water (n = 10). Ca2+ release in water was determined during 28 days by inductively coupled plasma optical emission spectrometry (n = 3). Statistical analysis was performed using ANOVA/Tukey test (DC: two-way; TP, %T; BFS and FM: one-way; Ca2+ release: repeated measures two-way, α = 5 %). RESULTS: CaSi and ß-TCP particles drastically reduced DC at 2 mm, TP and %T (p < 0.001). Compared to both controls, all Ca2+-releasing materials presented lower BFS (p < 0.001) and only the material with DCPD showed significantly lower FM (p < 0.05). The material containing CaSi presented the highest Ca2+ release, while among materials formulated with calcium orthophosphates the use of DCPD resulted in the highest release (p < 0.001). SIGNIFICANCE: CaSi particles allowed the highest Ca2+ release. Notwithstanding, the use of DCPD resulted in a material with the best compromise between optical behaviour, DC, strength and Ca2+ release.


Asunto(s)
Compuestos de Calcio , Fosfatos de Calcio , Ensayo de Materiales , Silicatos , Silicatos/química , Compuestos de Calcio/química , Fosfatos de Calcio/química , Espectroscopía Infrarroja por Transformada de Fourier , Durapatita/química , Resistencia Flexional , Ácidos Polimetacrílicos/química , Polietilenglicoles/química , Bisfenol A Glicidil Metacrilato/química , Resinas Compuestas/química , Vidrio/química , Calcio/química , Espectrofotometría , Fenómenos Químicos , Dióxido de Silicio , Compuestos de Bario
6.
Prim Dent J ; 13(2): 53-57, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38888075

RESUMEN

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Vidrio , Técnica de Perno Muñón , Humanos , Resinas Compuestas/química , Vidrio/química , Cementos de Resina/química , Coronas , Estética Dental , Retención de Prótesis Dentales , Materiales Dentales/química , Cementación
7.
Eur J Oral Sci ; 132(4): e13002, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38938069

RESUMEN

This study evaluated bond strength of glass fiber posts to root dentin using push-out (PO) and diametral compression (DC), testing glycolic acid as a conditioner and varying dentin moisture. An additional aim was to test whether DC can be an alternative test to PO for bond strength assessment. Eighty bovine teeth were divided into eight groups (n = 10) defined by the use of either 37% glycolic acid or 37% phosphoric acid (PA) on moist or wet dentin before bonding with either Adapter SingleBond/RelyX ARC or One Step Plus/Duo-Link Bisco. Each tooth provided discs with an internal diameter of 2 mm, external diameter of 5 mm, and height of 2 mm, which underwent PO and DC. Finite element analysis (FEA) was carried out on 3D models. When analyzing PO results through linear regression, the highest values of bond strength were observed using glycolic acid on wet dentin in the cervical and middle thirds of the teeth. Analyzing DC results, the only statistical influence on values was the dental thirds. The scatterplot of the DC results and the PO bond strength values indicated no relationship between the results of the two tests (r = 0.03; p = 0.64). PO test detected more sensitive changes in bond strength values than DC.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Análisis de Elementos Finitos , Vidrio , Ácidos Fosfóricos , Técnica de Perno Muñón , Animales , Bovinos , Dentina/efectos de los fármacos , Vidrio/química , Ácidos Fosfóricos/química , Recubrimientos Dentinarios/química , Cementos de Resina/química , Análisis del Estrés Dental , Ensayo de Materiales , Raíz del Diente , Glicolatos/química , Grabado Ácido Dental
8.
Clin Oral Investig ; 28(7): 386, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38890207

RESUMEN

OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Técnica de Perno Muñón , Cementos de Resina , Humanos , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Dentina/efectos de la radiación , Técnicas In Vitro , Recubrimientos Dentinarios/química , Análisis del Estrés Dental , Propiedades de Superficie , Raíz del Diente/efectos de la radiación , Ultrasonido , Grabado Ácido Dental , Incisivo , Vidrio/química
9.
FEMS Microbiol Lett ; 3712024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38866708

RESUMEN

This study aimed to investigating the possible interference caused by glass test tubes on the quantification of bacterial adhesion to hydrocarbons by the MATH test. The adhesion of four bacteria to hexadecane and to glass test tubes was evaluated employing different suspending polar phases. The role of the ionic strength of the polar phase regarding adhesion to glassware was investigated. Within the conditions studied, Gram-positive bacteria adhered to both the test tube and the hydrocarbon regardless of the polar phase employed; meanwhile, Escherichia coli ATCC 25922 did not attach to either one. The capacity of the studied microorganisms to adhere to glassware was associated with their electron-donor properties. The ionic strength of the suspending media altered the patterns of adhesion to glass in a strain-specific manner by defining the magnitude of electrostatic repulsion observed between bacteria and the glass surface. This research demonstrated that glass test tubes may interact with suspended bacterial cells during the MATH test under specific conditions, which may lead to overestimating the percentage of adhesion to hydrocarbons and, thus, to erroneous values of cell surface hydrophobicity.


Asunto(s)
Adhesión Bacteriana , Vidrio , Vidrio/química , Escherichia coli , Alcanos/química , Concentración Osmolar , Interacciones Hidrofóbicas e Hidrofílicas , Hidrocarburos/metabolismo , Bacterias Grampositivas/aislamiento & purificación
10.
Sci Rep ; 14(1): 13262, 2024 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858417

RESUMEN

The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.


Asunto(s)
Dentina , Vidrio , Ensayo de Materiales , Circonio , Circonio/química , Vidrio/química , Dentina/química , Humanos , Microscopía Electrónica de Rastreo , Propiedades de Superficie
11.
Dent Mater ; 40(7): 1041-1046, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38763819

RESUMEN

OBJECTIVE: To evaluate the influence of the barium glass (BG) filler in 3D printing resin-based composites for restorative structures. METHODS: Experimental 3D printing resin-based composites were formulated with UDMA 70%wt, Bis-EMA 20%wt, and TEGDMA 10%wt. Photoinitiators TPO and DFI (2%wt) were used. BG was incorporated at 40%wt and 50%wt. 0%wt BG was used as negative control and the VarseoSmile Crownplus (Bego) was used as a commercial control. Specimens were printed using a 3D printer. Subsequently, specimens were washed and submitted to post-curing with 405 nm at 60ºC for 2 × 20 min at FormCure (FormLabs). 3D printing resin-based composites were evaluated by flexural strength, degree of conversion, softening in solvent, radiopacity, and cytotoxicity against gingival fibroblasts. Data were statistically analyzed using one-way ANOVA (α = 0.05). RESULTS: No significant differences in flexural strength were showed between BG40% (90.5 ± 5,4 MPa), BG50% (102.0 ± 11.7 MPa) and VA (105.2 ± 11.7 MPa). Addition of 40% and 50% of BG showed no influence in the degree of conversion compared to VA (p > 0.05). All groups showed softening in solvent after immersion in ethanol (p < 0.05). All groups showed more than 1mmAl of radiopacity. BG50% showed significantly higher radiopacity (2.8 ± 0.3 mmAl) than other groups (p < 0,05). Cytotoxicity evaluation showed gingival cell viability higher than 80% for all groups. SIGNIFICANCE: Addition of up to 50%wt of barium glass in experimental 3D printing resin-based composites showed promising results for long-term restorative structures.


Asunto(s)
Compuestos de Bario , Resinas Compuestas , Ensayo de Materiales , Metacrilatos , Polietilenglicoles , Impresión Tridimensional , Resinas Compuestas/química , Compuestos de Bario/química , Polietilenglicoles/química , Metacrilatos/química , Poliuretanos/química , Resistencia Flexional , Vidrio/química , Ácidos Polimetacrílicos/química , Bisfenol A Glicidil Metacrilato/química , Humanos , Fibroblastos/efectos de los fármacos , Encía , Fotoiniciadores Dentales/química , Polimerizacion , Propiedades de Superficie , Dióxido de Silicio
12.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795258

RESUMEN

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Asunto(s)
Benzofenonas , Coronas , Pilares Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Titanio , Circonio , Cetonas/química , Polietilenglicoles/química , Humanos , Circonio/química , Titanio/química , Fibra de Carbono/química , Diseño de Implante Dental-Pilar , Incisivo , Materiales Dentales/química , Implantes Dentales de Diente Único , Hueso Cortical , Vidrio/química , Diseño de Prótesis Dental
13.
Braz Dent J ; 35: e245720, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38775593

RESUMEN

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Asunto(s)
Dentina , Técnica de Perno Muñón , Cementos de Resina , Bovinos , Animales , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Bisfenol A Glicidil Metacrilato/química , Recubrimientos Dentinarios/química , Microscopía Confocal , Ácidos Polimetacrílicos/química , Ensayo de Materiales , Vidrio/química , Raíz del Diente , Polietilenglicoles/química , Análisis del Estrés Dental
14.
J Biomater Sci Polym Ed ; 35(10): 1493-1510, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38569077

RESUMEN

In recent years, there has been a notable surge of interest in hybrid materials within the biomedical field, particularly for applications in bone repair and regeneration. Ceramic-polymeric hybrid scaffolds have shown promising outcomes. This study aimed to synthesize bioactive glass (BG-58S) for integration into a bioresorbable polymeric matrix based on PDLLA, aiming to create a bioactive scaffold featuring stable pH levels. The synthesis involved a thermally induced phase separation process followed by lyophilization to ensure an appropriate porous structure. BG-58S characterization revealed vitreous, bioactive, and mesoporous structural properties. The scaffolds were analyzed for morphology, interconnectivity, chemical groups, porosity and pore size distribution, zeta potential, pH, in vitro degradation, as well as cell viability tests, total protein content and mineralization nodule production. The PDLLA scaffold displayed a homogeneous morphology with interconnected macropores, while the hybrid scaffold exhibited a heterogeneous morphology with smaller diameter pores due to BG-58S filling. The hybrid scaffold also demonstrated a pH buffering effect on the polymer surface. In addition to structural characteristics, degradation tests indicated that by incorporating BG-58S modified the acidic degradation of the polymer, allowing for increased total protein production and the formation of mineralization nodules, indicating a positive influence on cell culture.


Asunto(s)
Regeneración Ósea , Cerámica , Vidrio , Poliésteres , Andamios del Tejido , Cerámica/química , Andamios del Tejido/química , Regeneración Ósea/efectos de los fármacos , Vidrio/química , Porosidad , Poliésteres/química , Materiales Biocompatibles/química , Concentración de Iones de Hidrógeno , Humanos , Supervivencia Celular/efectos de los fármacos , Ensayo de Materiales
15.
Biomolecules ; 14(4)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38672498

RESUMEN

Inorganic-organic hybrid biomaterials have been proposed for bone tissue repair, with improved mechanical flexibility compared with scaffolds fabricated from bioceramics. However, obtaining hybrids with osteoinductive properties equivalent to those of bioceramics is still a challenge. In this work, we present for the first time the synthesis of a class II hybrid modified with bioactive glass nanoparticles (nBGs) with osteoinductive properties. The nanocomposite hybrids were produced by incorporating nBGs in situ into a polytetrahydrofuran (PTHF) and silica (SiO2) hybrid synthesis mixture using a combined sol-gel and cationic polymerization method. nBGs ~80 nm in size were synthesized using the sol-gel technique. The structure, composition, morphology, and mechanical properties of the resulting materials were characterized using ATR-FTIR, 29Si MAS NMR, SEM-EDX, AFM, TGA, DSC, mechanical, and DMA testing. The in vitro bioactivity and degradability of the hybrids were assessed in simulated body fluid (SBF) and PBS, respectively. Cytocompatibility with mesenchymal stem cells was assessed using MTS and cell adhesion assays. Osteogenic differentiation was determined using the alkaline phosphatase activity (ALP), as well as the gene expression of Runx2 and Osterix markers. Hybrids loaded with 5, 10, and 15% of nBGs retained the mechanical flexibility of the PTHF-SiO2 matrix and improved its ability to promote the formation of bone-like apatite in SBF. The nBGs did not impair cell viability, increased the ALP activity, and upregulated the expression of Runx2 and Osterix. These results demonstrate that nBGs are an effective osteoinductive nanoadditive for the production of class II hybrid materials with enhanced properties for bone tissue regeneration.


Asunto(s)
Materiales Biocompatibles , Vidrio , Células Madre Mesenquimatosas , Nanocompuestos , Nanopartículas , Osteogénesis , Nanocompuestos/química , Nanopartículas/química , Vidrio/química , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Osteogénesis/efectos de los fármacos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Humanos , Dióxido de Silicio/química , Diferenciación Celular/efectos de los fármacos , Ingeniería de Tejidos/métodos
16.
Int J Mol Sci ; 25(8)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38673856

RESUMEN

Immune response to biomaterials, which is intimately related to their surface properties, can produce chronic inflammation and fibrosis, leading to implant failure. This study investigated the development of magnetic nanoparticles coated with silica and incorporating the anti-inflammatory drug naproxen, aimed at multifunctional biomedical applications. The synthesized nanoparticles were characterized using various techniques that confirmed the presence of magnetite and the formation of a silica-rich bioactive glass (BG) layer. In vitro studies demonstrated that the nanoparticles exhibited bioactive properties, forming an apatite surface layer when immersed in simulated body fluid, and biocompatibility with bone cells, with good viability and alkaline phosphatase activity. Naproxen, either free or encapsulated, reduced nitric oxide production, an inflammatory marker, while the BG coating alone did not show anti-inflammatory effects in this study. Overall, the magnetic nanoparticles coated with BG and naproxen showed promise for biomedical applications, especially anti-inflammatory activity in macrophages and in the bone field, due to their biocompatibility, bioactivity, and osteogenic potential.


Asunto(s)
Materiales Biocompatibles Revestidos , Vidrio , Nanopartículas de Magnetita , Naproxeno , Naproxeno/farmacología , Naproxeno/química , Vidrio/química , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Nanopartículas de Magnetita/química , Animales , Ratones , Humanos , Óxido Nítrico/metabolismo , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Dióxido de Silicio/química , Supervivencia Celular/efectos de los fármacos , Células RAW 264.7 , Osteogénesis/efectos de los fármacos
18.
Rev. Asoc. Odontol. Argent ; 112(1): 1120451, ene.-abr. 2024. ilus
Artículo en Español | LILACS | ID: biblio-1566068

RESUMEN

Los vidrios bioactivos (VBa) son materiales biocerámicos que tienen una extensa aplicación en medicina y odontología. A causa de su contenido de calcio y fosfato son muy simi- lares a la hidroxiapatita del tejido óseo. Su biocompatibili- dad y bioactividad los hacen materiales muy útiles para ser aplicados en diferentes áreas de la práctica dental, tales como periodoncia, cirugía, odontología restauradora y endodoncia. En endodoncia los VBa están indicados para realizar protec- ciones pulpares directas, pulpotomías, desinfecciones y obtu- raciones del sistema de conductos radiculares. El objetivo del presente trabajo fue realizar una revisión de las propiedades biológicas de los VBa en relación a sus aplicaciones en en- dodoncia (AU)


Bioactive glasses (BGs) are bioceramic materials with extensive clinical applications in medicine and dentistry. Be- cause of their phosphate and calcium contents, they are like the hydroxyapatiteof bone tissue. Their biocompatibility and bioactivity make them very useful biomaterials in different areas of dental practice, such as periodontics, oral surgery, restorative dentistry, and endodontics. In endodontics, bioac- tive glasses are indicated for direct pulp capping, pulpoto- mies, disinfections and fillings of the root canal system. The aim of this work was to carry out a review of the biological properties of BGs in relation to its application in endodontics (AU)


Asunto(s)
Humanos , Animales , Materiales de Obturación del Conducto Radicular/química , Materiales Biocompatibles/química , Durapatita/química , Narración , Recubrimiento de la Pulpa Dental/instrumentación , Fenómenos Químicos , Vidrio/química
19.
Braz Dent J ; 35: e245833, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537024

RESUMEN

The aim was to evaluate the effect of stress distribution on vertical, horizontal, and oblique forces on the tooth model after reattaching the fragments of the maxillary incisor with vertical root fracture (VRF) using different materials, by 3D finite element analysis (FEA). Tooth with a root canal, spongious, and cortical bone models were designed. VRF was modeled on a tooth with 4 different re-attachment models: Group 1: dual-cure cement (DC)+fiber reinforced composite (FRC), Group 2: DC+polyethylene fiber, Group 3: DC+glass fiber, and Group 4:DC. 100 N force was applied in 3 different directions. Maximum principal stresses (σmax) of dentin, and re-attachment materials were evaluated on colored images. The highest σmax values ​​were on the repair materials under vertical forces for Groups 1 and 4, respectively; Groups 2 and 3 showed similarity. The highest σmax values in repair materials under horizontal and oblique forces were observed in Group 3 however the lowest σmax values in repair materials under oblique and horizontal forces were observed in Group 1. The stress values ​​on repair materials gradually increased respectively starting from horizontal to vertical. As the elasticity modulus of the repair materials increased, the stress values ​​on root dentin increased. Through all force directions, except vertical forces, lower stress values were observed with FRC. The fracture resistance was bigger when using solely FRC or dual-cure resin cement in comparison to fiber-supported designs. Adding polyethylene fiber to re-restorations decreased stress values ​​compared to glass fiber addition. Therefore, when adding fibers, polyethylene fiber will be advantageous.


Asunto(s)
Materiales Dentales , Técnica de Perno Muñón , Resinas Compuestas , Cavidad Pulpar , Análisis de Elementos Finitos , Polietileno , Estrés Mecánico , Ensayo de Materiales , Análisis del Estrés Dental , Vidrio
20.
Anal Chim Acta ; 1297: 342336, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38438226

RESUMEN

BACKGROUND: Developing disposable paper-based devices has positively impacted analytical science, particularly in developing countries. Some benefits of those devices include their versatility, affordability, environmentally friendly, and the possibility of being integrated with portable electrochemical or colorimetric detectors. Paper-based analytical devices (PADs) comprising circular zones and microfluidic networks have been successfully employed in the analytical chemistry reign. However, the combination of the stencil-printing method and alternative binder has not been satisfactorily explored for fabricating colorimetric paper devices. RESULTS: We developed PADs exploring the stencil printing approach and glass varnish as the hydrophobic chemical agent. As a proof-of-concept, the colorimetric assay of salivary α-amylase (sAA) was performed in saliva samples. Through the scanning electron microscopy measurements, it was possible to indicate satisfactory definitions between native fibers and barrier, and that the measured values for the channel width revealed suitable fidelity (R2 = 0.99) with the nominal widths (ranging from 400 to 5000 µm). The proposed hydrophobic barrier exhibited excellent chemical resistance. The analytical applicability for detecting sAA revealed linear behavior in the range from 2 to 12 U mL-1 (R2 = 0.99), limit of detection of 0.75 U mL-1, reproducibility (RSD ≤2.4%), recovery experiments ranged from 89 to 108% and AGREE response (0.86). In addition, the colorimetric analysis of sAA in four different saliva samples demonstrated levels ranging from 202 to 2080 U mL-1, which enabled monitoring the absence and presence of periodontitis. SIGNIFICANCE: This report has presented the first use of a self-adhesive mask and glass varnish for creating circular zones and microfluidic architectures on paper without using thermic or UV curing treatments. Also, the proposed analytical methodology for detecting sAA exhibited suitable ecological impact considering the AGREE tool. We believe the proposed fabrication of paper devices emerges as a novel, simple, high-fidelity microfluidic channel and portable analytical approach for colorimetric sensing.


Asunto(s)
Colorimetría , alfa-Amilasas Salivales , Reproducibilidad de los Resultados , Bioensayo , Vidrio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA