Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 309
Filtrar
1.
J Orthop Traumatol ; 25(1): 39, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39152298

RESUMEN

BACKGROUND: Glenoid version is an important factor in the evaluation of shoulder stability and shoulder pathologies. However, there are neither established reference values nor known factors that influence the glenoid version, even though valid reference values are needed for diagnostic and orthopaedic surgery like corrective osteotomy and total or reverse shoulder arthroplasty (TSA/RSA). The aim of our population-based study was to identify factors influencing the glenoid version and to establish reference values from a large-scale population cohort. RESULTS: Our study explored the glenoid versions in a large sample representing the general adult population. We investigated 3004 participants in the population-based Study of Health in Pomerania (SHIP). Glenoid version was measured for both shoulders via magnetic resonance imaging (MRI). Associations with the glenoid version were calculated for sex, age, body height, body weight and BMI. The reference values for glenoid version in the central European population range between -9° and 7.5°, while multiple factors are associated with the glenoid version. CONCLUSION: To achieve a reliable interpretation prior to orthopaedic surgery, sex- and age-adjusted reference values are proposed.


Asunto(s)
Imagen por Resonancia Magnética , Articulación del Hombro , Humanos , Femenino , Masculino , Valores de Referencia , Persona de Mediana Edad , Adulto , Factores Sexuales , Anciano , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Alemania , Adulto Joven , Factores de Edad , Cavidad Glenoidea/diagnóstico por imagen
2.
Int Orthop ; 48(8): 2129-2136, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38833167

RESUMEN

PURPOSE: Measurement of glenoid bone loss in the shoulder instability can be assessed by CT or MRI multiplanar imaging and is crucial for pre-operative planning. The aim of this study is to determine the intra and interobserver reliability of glenoid deficiency measurement using MRI multiplanar reconstruction with 2D assessment in the sagittal plane (MPR MRI). METHODS: We reviewed MRI images of 80 patients with anterior shoulder instability with Osirix software using MPR. Six observers with basic experience measured the glenoid, erosion edge length, and bone loss twice, with at least one-week interval between measurements. We calculated reliability and repeatability using the intra-class correlation coefficient (ICC) and minimal detectable change with 95% confidence (MDC95%). RESULTS: Intra and Inter-observer ICC and MDC95% for glenoid width and height were excellent (ICC 0,89-0,96). For erosion edge length and area of the glenoid were acceptable/good (ICC 0,61-0,89). Bone loss and Pico Index were associated with acceptable/good ICC (0,63 -0,86)) but poor MDC95% (45 - 84 %). Intra-observer reliability improved with time, while inter-observer remained unchanged. CONCLUSION: The MPR MRI measurement of the anterior glenoid lesion is very good tool for linear parameters. This method is not valid for Pico index measurement, as the area of bone loss is variable. The pace of learning is individual, therefore complex calculations based on MPR MRI are not resistant to low experience as opposed to true 3D CT.


Asunto(s)
Inestabilidad de la Articulación , Imagen por Resonancia Magnética , Variaciones Dependientes del Observador , Articulación del Hombro , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/patología , Masculino , Femenino , Adulto , Adulto Joven , Persona de Mediana Edad , Adolescente , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/patología , Estudios Retrospectivos , Procesamiento de Imagen Asistido por Computador/métodos
3.
Eur J Radiol ; 177: 111588, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38944907

RESUMEN

OBJECTIVES: To develop and validate an open-source deep learning model for automatically quantifying scapular and glenoid morphology using CT images of normal subjects and patients with glenohumeral osteoarthritis. MATERIALS AND METHODS: First, we used deep learning to segment the scapula from CT images and then to identify the location of 13 landmarks on the scapula, 9 of them to establish a coordinate system unaffected by osteoarthritis-related changes, and the remaining 4 landmarks on the glenoid cavity to determine the glenoid size and orientation in this scapular coordinate system. The glenoid version, glenoid inclination, critical shoulder angle, glenopolar angle, glenoid height, and glenoid width were subsequently measured in this coordinate system. A 5-fold cross-validation was performed to evaluate the performance of this approach on 60 normal/non-osteoarthritic and 56 pathological/osteoarthritic scapulae. RESULTS: The Dice similarity coefficient between manual and automatic scapular segmentations exceeded 0.97 in both normal and pathological cases. The average error in automatic scapular and glenoid landmark positioning ranged between 1 and 2.5 mm and was comparable between the automatic method and human raters. The automatic method provided acceptable estimates of glenoid version (R2 = 0.95), glenoid inclination (R2 = 0.93), critical shoulder angle (R2 = 0.95), glenopolar angle (R2 = 0.90), glenoid height (R2 = 0.88) and width (R2 = 0.94). However, a significant difference was found for glenoid inclination between manual and automatic measurements (p < 0.001). CONCLUSIONS: This open-source deep learning model enables the automatic quantification of scapular and glenoid morphology from CT scans of patients with glenohumeral osteoarthritis, with sufficient accuracy for clinical use.


Asunto(s)
Aprendizaje Profundo , Osteoartritis , Escápula , Articulación del Hombro , Tomografía Computarizada por Rayos X , Humanos , Escápula/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Osteoartritis/diagnóstico por imagen , Masculino , Femenino , Articulación del Hombro/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Cavidad Glenoidea/diagnóstico por imagen , Adulto , Reproducibilidad de los Resultados , Puntos Anatómicos de Referencia/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
J Am Acad Orthop Surg ; 32(15): e777-e784, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38857595

RESUMEN

INTRODUCTION: Reverse total shoulder arthroplasty (RTSA) with structural bone graft has been described as a technique in addressing glenoid bony defects. Studies have demonstrated acceptable outcomes with structural autograft or allograft. However, most of these studies are relatively small and rarely evaluate bone graft incorporation with CT scan. The aim of this study was to assess clinical and radiographic outcomes and report graft incorporation assessed on CT scan after RTSA where structural bone autograft or allograft was used to reconstruct the glenoid. METHODS: From May 2011 through June 2016, 38 patients underwent RTSA with structural bone graft. Of these, 35 were available for a minimum 2-year follow-up and retrospectively enrolled. From July 2016 through February 2019, 32 patients undergoing RTSA with structural bone graft were prospectively enrolled. Preoperative and postoperative American Shoulder and Elbow Surgeons and visual analog scale (for pain) scores and radiographs were obtained. CT scan was obtained at least 1 year postoperatively. RESULTS: Thirty-five patients were enrolled retrospectively (52.2%) and 32 prospectively (47.8%). Autograft was used in 46 cases (68.7%) and allograft in 21 cases. The mean American Shoulder and Elbow Surgeons score improved from 33.1 (SD 18.5) to 78.2 (SD 22.4), with P < 0.0001. On postoperative radiographs, 63 cases (94.0%) showed stable RTSA constructs while four cases (6.0%) developed glenoid baseplate subsidence. Postoperative CT scan demonstrated complete graft incorporation in 45 cases (90.0%) while partial incorporation was noted in 4 cases (8.0%), and in 1 case (2.0%), there was no graft incorporation. No correlation was observed between baseplate subsidence and graft type (autograft versus allograft) or primary versus revision surgery. DISCUSSION: Reverse shoulder arthroplasty with structural bone autograft and allograft is reliable for glenoid augmentation in patients undergoing RTSA in both primary and revision settings. Bony incorporation of autograft and allograft as evaluated on CT scan is predictably high.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Trasplante Óseo , Tomografía Computarizada por Rayos X , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Trasplante Óseo/métodos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Aloinjertos , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Autoinjertos , Trasplante Autólogo
5.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241254913, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38749489

RESUMEN

Different techniques have been described for glenoid fractures, there is still a need for safe and effective agents to promote outcomes. From January 2016 to April 2021, the clinical data of 17 patients with pulley type IA fractures treated by the V-shaped fixation technique under shoulder arthroscopy were retrospectively analyzed. Preoperative X-ray, CT, and MRI examinations were completed. The functional score of the shoulder joint, such as the visual analog scale (VAS), Constant score, and Modified Rowe score, was used to evaluate the preoperative and final follow-up clinical outcomes. The active shoulder range of motion (ROM) was also collected preoperatively and at the final postoperative follow-up. Accordingly, intraoperative and postoperative complications were also observed. The mean follow-up was 49.52 months (16-79 months). The patients' follow-up exams showed that shoulder joint flexion, abduction, external rotation, internal rotation, and pain were not significantly different from those of the contralateral side (p > .05). The mean Constant score was 83.52 (58-98), and the average Modified Rowe score was 94.29 (70-100). X-ray and CT films of all cases showed good healing without articular depression or steps. Three patients had traumatic arthritis, with VAS <3 pain. No postoperative complications, such as infections, nerve or vessel damage, or suture anchor problems occurred during the follow-up period. Using the Double-pull, V-shaped fixation technique can stabilize the reduction of glenoid fractures while reducing the possibility of bone destruction. It is a good solution and provides an opportunity to treat rotator cuff tears associated with the procedure.


Asunto(s)
Artroscopía , Fijación Interna de Fracturas , Humanos , Masculino , Artroscopía/métodos , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Fijación Interna de Fracturas/métodos , Rango del Movimiento Articular , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen
6.
Eur J Orthop Surg Traumatol ; 34(5): 2353-2364, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38592552

RESUMEN

PURPOSE: The anterior stability of reverse total shoulder arthroplasty is affected by multiple factors. However, the effect of glenosphere inclination on stability has rarely been investigated, which is what this study aims to look into. METHODS: Reverse shoulder arthroplasty was performed on 15 cadaveric human shoulders. The anterior dislocation forces and range of motion in internal rotation in the glenohumeral joint (primary measured parameters) were tested in a shoulder simulator in different arm positions and implant configurations, as well as with a custom-made 10° inferiorly inclined glenosphere. The inclination and retroversion of the baseplate as well as the distance between the glenoid and coracoid tip in two planes (secondary measured parameters) were evaluated on CT scans. RESULTS: In biomechanical testing, the custom-made inclined glenosphere showed no significant influence on anterior stability other than glenoid lateralisation over all arm positions as well as the neck-shaft angle in two arm positions. The 6 mm lateralised glenosphere reduced internal rotation at 30° and 60° of glenohumeral abduction. In 30° of glenohumeral abduction, joint stability was increased using the 155° epiphysis compared with the 145° epiphysis. The mean inclination was 16.1°. The inclination was positively, and the distance between the glenoid and coracoid tip in the anterior-to-posterior direction was negatively correlated with anterior dislocation forces. CONCLUSIONS: The custom-made inferiorly inclined glenosphere did not influence anterior stability, but baseplate inclination itself had a significant effect on stability.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cadáver , Rango del Movimiento Articular , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiología , Articulación del Hombro/fisiopatología , Fenómenos Biomecánicos , Rango del Movimiento Articular/fisiología , Anciano , Inestabilidad de la Articulación/fisiopatología , Inestabilidad de la Articulación/etiología , Femenino , Masculino , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/fisiología , Prótesis de Hombro , Tomografía Computarizada por Rayos X , Anciano de 80 o más Años , Diseño de Prótesis
7.
Mymensingh Med J ; 33(2): 334-340, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38557507

RESUMEN

This cross-sectional descriptive purposive study was conducted among 150 (70 right and 80 left) fully ossified dry human scapulae of Bangladeshi people from January 2019 to December 2019 in the Department of Anatomy, Mymensingh Medical College, Mymensingh. Shape of the glenoid cavity was observed as pear, oval or inverted comma shape. Morphometric parameters such as length and breadth of glenoid cavity were measured by digital Vernier slide calipers. In this study, 19.13% cases were found inverted comma shaped, 35.65% cases were oval and 45.22% cases were pear shaped. The mean±SD length of glenoid cavity was 37.5±3.61 mm and 36.19±3.68 mm on right and left sided scapulae respectively and mean±SD breadth was 23.6±2.73 mm on right and 23.42±2.75 mm on left side respectively. Mean±SD glenoid cavity index was 62.89±4.39 on right and 64.61±4.74 on left sided scapulae. Morphometric analysis of glenoid fossa of scapula might help clinicians in shoulder and its associated diseases.


Asunto(s)
Cavidad Glenoidea , Personas del Sur de Asia , Humanos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/anatomía & histología , Estudios Transversales , Escápula/anatomía & histología , Pueblo Asiatico
8.
J Shoulder Elbow Surg ; 33(9): 2057-2063, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38467182

RESUMEN

BACKGROUND: The extent of measurement errors of statistical shape models that predict native glenoid width based on glenoid height to subsequently determine the amount of anterior glenoid bone loss is unclear. Therefore, the aim of this study was to (1) create a statistical shape model based on glenoid height and width measured on 3-dimensional computed tomography (3D-CT) and determine the accuracy through measurement errors and (2) determine measurement errors of existing 3D-CT statistical shape models. MATERIALS AND METHODS: A retrospective cross-sectional study included all consecutive patients who underwent CT imaging before undergoing primary surgical treatment of traumatic anterior shoulder dislocation between 2007 and 2022 at the Tohoku University Hospital and affiliated hospitals. Patients were included when instability was unilateral and CT scans of both the injured and contralateral uninjured shoulder were available. 3D segmentations were created and glenoid height and width of the injured and contralateral uninjured side (gold standard) were measured. Accuracy was determined through measurement errors, which were defined as a percentage error deviation from native glenoid width (contralateral uninjured glenoid), calculated as follows: measurement error = [(estimated glenoid width with a statistical shape model - native glenoid width) / native glenoid width] × 100%. A linear regression analysis was performed to create a statistical shape model based on glenoid height according to the formula: native glenoid width = a × glenoid height + b. RESULTS: The diagnosis and procedure codes identified 105 patients, of which 69 (66%) were eligible for inclusion. Glenoid height demonstrated a very strong correlation (r = 0.80) with native glenoid width. The linear regression formula based on this cohort was as follows: native glenoid width = 0.75 × glenoid height - 0.61, and it demonstrated an absolute average measurement error of 5% ± 4%. The formulas by Giles et al, Chen et al and Rayes et al demonstrated absolute average measurement errors of 10% ± 7%, 6% ± 5%, and 9% ± 6%, respectively. CONCLUSION: Statistical shape models that estimate native glenoid width based on glenoid height demonstrate unacceptable measurement errors, despite a high correlation. Therefore, great caution is advised when using these models to determine glenoid bone loss percentage. To minimize errors caused by morphologic differences, preference goes to methods that use the contralateral side as reference.


Asunto(s)
Imagenología Tridimensional , Modelos Estadísticos , Tomografía Computarizada por Rayos X , Humanos , Estudios Transversales , Estudios Retrospectivos , Masculino , Femenino , Tomografía Computarizada por Rayos X/métodos , Adulto , Persona de Mediana Edad , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/anatomía & histología , Articulación del Hombro/cirugía , Luxación del Hombro/diagnóstico por imagen , Adulto Joven , Adolescente , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/anatomía & histología
9.
Sci Rep ; 14(1): 6500, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499695

RESUMEN

Scapular surgery has usually been performed through the posterior Judet approach. This approach allows access to the entire posterior scapular body, but causes significant soft tissue damage and detaches the deltoid muscle. To date, there has been no clinical study of a deltoid-preserving approach to access the joint for displaced postero-inferior glenoid fractures (Ideberg type II or Ib). We describe an easy and less invasive approach to the postero-inferior glenoid fossa.


Asunto(s)
Fracturas Óseas , Cavidad Glenoidea , Humanos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Hombro/diagnóstico por imagen , Hombro/cirugía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fijación Interna de Fracturas
10.
J Craniomaxillofac Surg ; 52(5): 570-577, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38485626

RESUMEN

The aim of this study was to evaluate condylar and glenoid fossa remodeling after bimaxillary orthognathic surgery guided by patient-specific mandibular implants. In total, 18 patients suffering from dentofacial dysmorphism underwent a virtually planned bimaxillary mandibular PSI-guided orthognathic procedure. One month prior to surgery, patients underwent a CBCT scan and optical scans of the dental arches; these datasets were re-acquired 1 month and at least 9 months postsurgery. Three-dimensional models of the condyles, glenoid fossae, and interarticular surface space (IASS) were obtained and compared to evaluate the roto-translational positional discrepancy and surface variation of each condyle and glenoid fossa, and the IASS variation. The condylar position varied by an average of 4.31° and 2.18 mm, mainly due to surgically unavoidable ramus position correction. Condylar resorption remodeling was minimal (average ≤ 0.1 mm), and affected skeletal class III patients the most. Later condylar remodeling was positively correlated with patient age. No significant glenoid fossa remodeling was observed. No postoperative orofacial pain was recorded at clinical follow-up. The procedure was accurate in minimizing the shift in relationship between the bony components of the TMJ and their remodeling, and was effective in avoiding postoperative onset of orofacial pain. An increase in sample size, however, would be useful to confirm our findings.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Procedimientos Quirúrgicos Ortognáticos , Articulación Temporomandibular , Humanos , Femenino , Masculino , Adulto , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/cirugía , Procedimientos Quirúrgicos Ortognáticos/métodos , Mandíbula/cirugía , Mandíbula/diagnóstico por imagen , Cóndilo Mandibular/diagnóstico por imagen , Cóndilo Mandibular/cirugía , Cóndilo Mandibular/patología , Adulto Joven , Remodelación Ósea/fisiología , Imagenología Tridimensional/métodos , Maxilar/cirugía , Maxilar/diagnóstico por imagen , Adolescente , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/patología , Cavidad Glenoidea/cirugía
11.
Int Orthop ; 48(4): 1057-1063, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38302596

RESUMEN

PURPOSE: The aim of the study reveals a new intuitive method for preoperatively assessing defect ratio in glenoid deficiency based on the native glenoid width and the bare spot. METHODS: A linear relationship, i.e. the rh formula, between the native glenoid width (2r) and height (h) was revealed by a cadaver cohort (n = 204). To validate the reliability of the rh formula, 280 3D-CT images of intact glenoids were recruited. To evaluate the accuracy of rh formula in estimating glenoid defect, the 65 anterior-inferior defect models were artificially established based on the 3D-CT images of intact glenoids. Moreover, a clinically common anterior-posterior (AP) method was compared with the rh formula, to verify the technical superiority of rh formula. RESULTS: The regression analysis indicated a linear relationship between the width and height of intact glenoid: 2r = 0.768 × h - 1.222 mm (R2 = 0.820, p < 0.001). An excellent reliability was found between the formula prediction and model width (ICC = 0.911, p = 0.266). An excellent agreement was found between the predicted values and model parameters (glenoid width, ICCrh = 0.967, prh = 0.778; defect ratio, prh = 0.572, ICCrh = 0.997). And, it is of higher accuracy compared to the AP method (glenoid width, ICCAP = 0.933, pAP = 0.001; defect ratio, ICCAP = 0.911, pAP = 0.033). CONCLUSION: Applying the cadaver-based formula on 3D-CT scans accurately predicts native glenoid width and redefines bare spot for preoperatively determining glenoid bone loss.


Asunto(s)
Enfermedades Óseas Metabólicas , Cavidad Glenoidea , Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Escápula/diagnóstico por imagen , Cadáver , Cavidad Glenoidea/diagnóstico por imagen
12.
J Shoulder Elbow Surg ; 33(9): 2048-2056, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38423250

RESUMEN

BACKGROUND: Descriptions of glenoid deformities in glenohumeral osteoarthritis (GHOA) have focused on the axial plane. Less is known regarding arthritic glenoids with higher amounts of superior inclination and little evidence exists to guide management of inclination or combined version-inclination deformity when performing anatomic total shoulder arthroplasty (aTSA). We hypothesized that biplanar deformities (BD) would be present in a higher proportion of GHOA patients than previously appreciated, and these deformities would be difficult to adequately reconstruct with contemporary aTSA implants. METHODS: A retrospective query was performed of GHOA patients indicated for TSA 2012-2017 with a computed tomography (CT) scan within three months of surgery. Images were uploaded to three-dimensional (3D) software for automated measurements. Glenoids with superior inclination ≥10°, and retroversion ≥20° were considered to have BD. Walch classification was determined, and C-type glenoids were excluded. Rotator-cuff muscle cross-sectional area (CSA) was measured and fatty infiltration was graded. Glenoids with BD were virtually planned for aTSA with correction to neutral inclination and version, then with 5° superior inclination and 10° retroversion. RESULTS: Two-hundred and sixty-eight shoulders in 250 patients were included; average age was 65 years, 67% male. There were no differences in inclination between Walch types (P = .25). Twenty-nine shoulders with BD were identified (11%). These deformities were not associated with age (P = .47) or gender (P = .50) but were skewed towards Walch B-type, specifically B2 (P = .03). Acromial index and posterior humeral head subluxation were higher in BD patients (P = .04, P < .001, respectively). Biplanar deformities had similar cuff CSA compared to those without but were less frequently associated with fatty infiltration of the subscapularis (P = .05). When correcting to neutral version and inclination, 41% BD could not be reconstructed. Of those that could, 94% required augmented implants. When correcting to 5° superior inclination and 10° retroversion, 10% could not be reconstructed. Of those that could, 58% required augmented implants. With partial correction, augment use was predicted by retroversion >26° (P = .009). Inclination did not predict augment use (P = .90). Final implant position commonly involved unseating in the posterosuperior quadrant and cancellous exposure in the anteroinferior quadrant. CONCLUSIONS: This retrospective computed tomography (CT)-based study of 268 shoulders with GHOA found an 11% prevalence of BD. These deformities were commonly associated with Walch B2 wear patterns. Virtual aTSA planning showed a high failure rate (41%) when correcting to neutral version and inclination. Posteriorly augmented implants were frequently required, and often still involved unseating in the posterosuperior quadrant, increased cancellous exposure in the anteroinferior quadrant, and vault perforation.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Imagenología Tridimensional , Osteoartritis , Articulación del Hombro , Prótesis de Hombro , Tomografía Computarizada por Rayos X , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Estudios Retrospectivos , Masculino , Femenino , Osteoartritis/cirugía , Osteoartritis/diagnóstico por imagen , Anciano , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Persona de Mediana Edad , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
13.
J Shoulder Elbow Surg ; 33(7): 1493-1502, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38242526

RESUMEN

BACKGROUND: The etiology of humeral posterior subluxation remains unknown, and it has been hypothesized that horizontal muscle imbalance could cause this condition. The objective of this study was to compare the ratio of anterior-to-posterior rotator cuff and deltoid muscle volume as a function of humeral subluxation and glenoid morphology when analyzed as a continuous variable in arthritic shoulders. METHODS: In total, 333 computed tomography scans of shoulders (273 arthritic shoulders and 60 healthy controls) were included in this study and were segmented automatically. For each muscle, the volume of muscle fibers without intramuscular fat was measured. The ratio between the volume of the subscapularis and the volume of the infraspinatus plus teres minor (AP ratio) and the ratio between the anterior and posterior deltoids (APdeltoid) were calculated. Statistical analyses were performed to determine whether a correlation could be found between these ratios and glenoid version, humeral subluxation, and/or glenoid type per the Walch classification. RESULTS: Within the arthritic cohort, no statistically significant difference in the AP ratio was found between type A glenoids (1.09 ± 0.22) and type B glenoids (1.03 ± 0.16, P = .09), type D glenoids (1.12 ± 0.27, P = .77), or type C glenoids (1.10 ± 0.19, P > .999). No correlation was found between the AP ratio and glenoid version (ρ = -0.0360, P = .55) or humeral subluxation (ρ = 0.076, P = .21). The APdeltoid ratio of type A glenoids (0.48 ± 0.15) was significantly greater than that of type B glenoids (0.35 ± 0.16, P < .01) and type C glenoids (0.21 ± 0.10, P < .01) but was not significantly different from that of type D glenoids (0.64 ± 0.34, P > .999). When evaluating both healthy control and arthritic shoulders, moderate correlations were found between the APdeltoid ratio and both glenoid version (ρ = 0.55, P < .01) and humeral subluxation (ρ = -0.61, P < .01). CONCLUSION: This in vitro study supports the use of software for fully automated 3-dimensional reconstruction of the 4 rotator cuff muscles and the deltoid. Compared with previous 2-dimensional computed tomography scan studies, our study did not find any correlation between the anteroposterior muscle volume ratio and glenoid parameters in arthritic shoulders. However, once deformity occurred, the observed APdeltoid ratio was lower with type B and C glenoids. These findings suggest that rotator cuff muscle imbalance may not be the precipitating etiology for the posterior humeral subluxation and secondary posterior glenoid erosion characteristic of Walch type B glenoids.


Asunto(s)
Músculo Deltoides , Manguito de los Rotadores , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Manguito de los Rotadores/diagnóstico por imagen , Músculo Deltoides/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Luxación del Hombro/diagnóstico por imagen , Adulto , Estudios de Casos y Controles , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/patología , Húmero/diagnóstico por imagen , Retroversión Ósea/diagnóstico por imagen , Estudios Retrospectivos
14.
J Shoulder Elbow Surg ; 33(5): 1058-1067, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37848155

RESUMEN

BACKGROUND: Angled bony-increased offset and metal-augmented baseplate have recently been used to achieve neutral to inferior inclination of the glenoid implant. Nonetheless, bone incorporation is difficult to evaluate using computed tomography or other conventional methods owing to the presence of metal artifacts; therefore, whether bone incorporation between the grafted bone and glenoid or between the graft and baseplate implant can be achieved remains unclear. Several studies have reported the effectiveness of tomosynthesis in reducing metal artifacts for the evaluation of implant loosening, bone resorption, and spot welds. We aimed to evaluate and compare the bone incorporation rates between angled bony-increased offset and metal-augmented implants using tomosynthesis with metal artifact reduction technology. We hypothesized that a high bone incorporation rate would be obtained with angled bony-increased offset and a metal-augmented baseplate. METHODS: A total of 52 patients who underwent reverse total shoulder arthroplasty (TSA) with angled bony-increased offset and 42 patients who underwent reverse total shoulder arthroplasty with metal-augmented baseplate were assessed and followed up for a minimum of 2 years. The bone incorporation and implant loosening rates were compared between the 2 groups, and the sites of spot welds and trabeculation were recorded according to zones. Bone incorporation between the bone and prosthesis was defined as a confirmation of spot welds connecting the porous area and bone in more than three zones. Bone incorporation between the native bone and grafted bone was defined as an observation of trabeculation. Glenoid loosening was defined as the presence of at least 1 mm radiolucency around the prosthesis in more than 2 zones. RESULTS: Both the angled bony-increased offset and metal-augmented baseplate groups achieved sufficient bone incorporation rates (98% [51/52 cases] vs. 100% [42/42 cases], P = 1.0) and low implant loosening rates (2% [1/52 cases] vs. 0% [0/42 cases], P = 1.0). Spot welds and trabeculation were likely to be confirmed in the lower parts of the glenoid. CONCLUSION: The two groups did not show any significant differences regarding bone incorporation rates. Considering the complexity of performing the procedure with angled bony-increased offset, the use of a metal-augmented baseplate can serve as an alternative treatment to avoid superior inclination in reverse total shoulder arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
15.
J Shoulder Elbow Surg ; 33(4): 792-797, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37852431

RESUMEN

BACKGROUND: Total shoulder arthroplasty (TSA) aims to reconstruct the premorbid anatomy of a pathologic shoulder. A healthy contralateral shoulder could be useful as a template in planning TSA. The symmetry between the left and right shoulders in healthy patients remains to be proved. The purpose of this study was to compare the 3-dimensional anatomy of the glenoid between sides in a healthy population. METHODS: A multinational computed tomography scan database was retrospectively reviewed for all healthy bilateral shoulders in patients aged between 18 and 50 years. One hundred thirty pairs of healthy shoulder computed tomography scans were analyzed, and glenoid version, inclination, width, and height, as well as glenoid lateral offset and scapula lateral offset, were measured. All anatomic measures were computed with Blueprint, validated 3-dimensional planning software. The intraclass correlation coefficient was determined for each measure between left and right shoulders. The minimal detectable change (MDC) was calculated using the following formula: MDC=2×1.96×Standarderrorofmeasurement. RESULTS: The comparison between 130 pairs of healthy scapulae showed statistically significant differences in absolute values between right and left glenoid version (-5.3° vs. -4.6°, P < .01), inclination (8.4° vs. 9.3°, P < .01), and width (25.6 mm vs. 25.4 mm, P < .01), as well as scapula offset (105.8 mm vs. 106.2 mm, P < .01). Glenoid height was comparable between right and left shoulders (33.3 mm vs. 33.3 mm, P = .9). The differences between the means were always inferior to the MDC regarding glenoid version, inclination, height, and width, as well as scapula offset. Very strong intraclass correlation coefficients between the left and right shoulders were found for all evaluated paired measures. CONCLUSION: Healthy contralateral scapulae are highly reliable to predict inclination, height, width, and scapula offset and are reliable to predict version of a given scapula. Paired right and left scapulae were not statistically symmetrical regarding mean glenoid version, inclination, and width, as well as scapula offset. Nevertheless, the reported differences were not higher than the MDC for this cohort, confirming that healthy contralateral shoulders can be a useful template in TSA preoperative planning.


Asunto(s)
Cavidad Glenoidea , Articulación del Hombro , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios Retrospectivos , Imagenología Tridimensional , Escápula/diagnóstico por imagen , Escápula/cirugía , Tomografía Computarizada por Rayos X , Cavidad Glenoidea/diagnóstico por imagen
16.
J Shoulder Elbow Surg ; 33(5): 1177-1184, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37890765

RESUMEN

BACKGROUND: Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. METHODS: Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. RESULTS: Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. CONCLUSIONS: The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Realidad Aumentada , Cavidad Glenoidea , Articulación del Hombro , Cirugía Asistida por Computador , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Cirugía Asistida por Computador/métodos , Cadáver , Imagenología Tridimensional/métodos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
17.
J Shoulder Elbow Surg ; 33(2): 223-233, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37774830

RESUMEN

BACKGROUND: Traditional, commercially sourced patient-specific instrumentation (PSI) systems for shoulder arthroplasty improve glenoid component placement but can involve considerable cost and outsourcing delays. The purpose of this randomized controlled trial was to compare the accuracy of glenoid component positioning in anatomic total shoulder arthroplasty (aTSA) using an in-house, point-of-care, 3-dimensionally (3D) printed patient-specific glenoid drill guide vs. standard nonspecific instrumentation. METHODS: This single-center randomized controlled trial included 36 adult patients undergoing primary aTSA. Patients were blinded and randomized 1:1 to either the PSI or the standard aTSA guide groups. The primary endpoint was the accuracy of glenoid component placement (version and inclination), which was determined using a metal-suppression computed tomography scan taken between 6 weeks and 1 year postoperatively. Deviation from the preoperative 3D templating plan was calculated for each patient. Blinded postoperative computed tomography measurements were performed by a fellowship-trained shoulder surgeon and a musculoskeletal radiologist. RESULTS: Nineteen patients were randomized to the patient-specific glenoid drill guide group, and 17 patients were allocated to the standard instrumentation control group. There were no significant differences between the 2 groups for native version (P = .527) or inclination (P = .415). The version correction was similar between the 2 groups (P = .551), and the PSI group was significantly more accurate when correcting version than the control group (P = .042). The PSI group required a significantly greater inclination correction than the control group (P = .002); however, the 2 groups still had similar accuracy when correcting inclination (P = .851). For the PSI group, there was no correlation between the accuracy of component placement and native version, native inclination, or the Walch classification of glenoid wear (P > .05). For the control group, accuracy when correcting version was inversely correlated with native version (P = .033), but accuracy was not correlated with native inclination or the Walch classification of glenoid wear (P > .05). The intraclass correlation coefficient was 0.703 and 0.848 when measuring version and inclination accuracy, respectively. CONCLUSION: When compared with standard instrumentation, the use of in-house, 3D printed, patient-specific glenoid drill guides during aTSA led to more accurate glenoid component version correction and similarly accurate inclination correction. Additional research should examine the influence of proper component position and use of PSI on clinical outcomes.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Escápula/cirugía , Artroplastia , Tomografía Computarizada por Rayos X , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Imagenología Tridimensional/métodos
18.
J Shoulder Elbow Surg ; 33(2): e58-e67, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37506998

RESUMEN

BACKGROUND: Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS: We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS: After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION: The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Cabeza Femoral/trasplante , Estudios Retrospectivos , Escápula/cirugía , Complicaciones Posoperatorias/etiología , Aloinjertos/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Resultado del Tratamiento , Rango del Movimiento Articular
19.
J Shoulder Elbow Surg ; 33(4): 872-879, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37689103

RESUMEN

BACKGROUND: Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS: We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS: Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION: This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Cavidad Glenoidea , Prótesis Articulares , Articulación del Hombro , Humanos , Polietileno , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Reproducibilidad de los Resultados , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
20.
J Shoulder Elbow Surg ; 33(7): e384-e399, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38122888

RESUMEN

BACKGROUND: Correction of glenoid retroversion is commonly performed in anatomic total shoulder arthroplasty (TSA) to increase component contact area and decrease eccentric loading of the glenoid component. Despite demonstrated biomechanical advantages, limited information exists on the clinical benefit of correcting glenoid retroversion. The purpose of this systematic review is to critically evaluate the existing literature on the effect of preoperative and postoperative glenoid retroversion on clinical functional and radiologic outcomes in patients who underwent anatomic TSA. METHODS: A systematic literature review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses using PubMed, Embase, and Cochrane Library evaluating the impact of glenoid retroversion on clinical and radiologic outcomes of TSA. English-language studies of level I through IV evidence were included. Blinded reviewers conducted multiple screens and methodological quality was appraised using the Modified Coleman Methodology Score. RESULTS: Sixteen studies, including 3 level III and 13 level IV studies (1211 shoulders), satisfied all inclusion criteria. To address glenoid retroversion, 9 studies used corrective reaming techniques, and 4 studies used posteriorly augmented glenoids. Two studies used noncorrective reaming techniques. Mean preoperative retroversion ranged from 12.7° to 24° across studies. Eleven studies analyzed the effect of glenoid retroversion on clinical outcomes, including patient-reported outcome scores (PROs), range of motion (ROM), or clinical failure or revision rates. Most studies (8 of 11) did not report any significant association of pre- or postoperative glenoid retroversion on any clinical outcome. Of the 3 studies that reported significant effects, 1 study reported a negative association between preoperative glenoid retroversion and PROs, 1 study reported inferior postoperative abduction in patients with postoperative glenoid retroversion greater than 15°, and 1 study found an increased clinical failure rate in patients with higher postoperative retroversion. Ten studies reported radiographic results (medial calcar resorption, Central Peg Lucency [CPL] grade, Lazarus lucency grade) at follow-up. Only 1 study reported a significant effect of pre- and postoperative retroversion greater than 15° on CPL grade. CONCLUSION: There is currently insufficient evidence that pre- or postoperative glenoid version influences postoperative outcomes independent of other morphologic factors such as joint line medialization. Given that noncorrective reaming demonstrated favorable postoperative outcomes, and postoperative glenoid version was not significantly and consistently found to impact outcomes, there is inconclusive evidence that correcting glenoid retroversion is routinely required.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Rango del Movimiento Articular , Articulación del Hombro/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA