Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31.540
Filtrar
1.
Cell Death Dis ; 15(7): 470, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956034

RESUMEN

The present study aims to develop and characterize a controlled-release delivery system for protein therapeutics in skeletal muscle regeneration following an acute injury. The therapeutic protein, a membrane-GPI anchored protein called Cripto, was immobilized in an injectable hydrogel delivery vehicle for local administration and sustained release. The hydrogel was made of poly(ethylene glycol)-fibrinogen (PEG-Fibrinogen, PF), in the form of injectable microspheres. The PF microspheres exhibited a spherical morphology with an average diameter of approximately 100 micrometers, and the Cripto protein was uniformly entrapped within them. The release rate of Cripto from the PF microspheres was controlled by tuning the crosslinking density of the hydrogel, which was varied by changing the concentration of poly(ethylene glycol) diacrylate (PEG-DA) crosslinker. In vitro experiments confirmed a sustained-release profile of Cripto from the PF microspheres for up to 27 days. The released Cripto was biologically active and promoted the in vitro proliferation of mouse myoblasts. The therapeutic effect of PF-mediated delivery of Cripto in vivo was tested in a cardiotoxin (CTX)-induced muscle injury model in mice. The Cripto caused an increase in the in vivo expression of the myogenic markers Pax7, the differentiation makers eMHC and Desmin, higher numbers of centro-nucleated myofibers and greater areas of regenerated muscle tissue. Collectively, these results establish the PF microspheres as a potential delivery system for the localized, sustained release of therapeutic proteins toward the accelerated repair of damaged muscle tissue following acute injuries.


Asunto(s)
Preparaciones de Acción Retardada , Músculo Esquelético , Polietilenglicoles , Animales , Músculo Esquelético/metabolismo , Músculo Esquelético/lesiones , Músculo Esquelético/efectos de los fármacos , Ratones , Polietilenglicoles/química , Microesferas , Fibrinógeno/metabolismo , Hidrogeles/química , Regeneración/efectos de los fármacos , Mioblastos/metabolismo , Mioblastos/efectos de los fármacos , Humanos , Proliferación Celular/efectos de los fármacos , Factor de Transcripción PAX7/metabolismo , Masculino , Ratones Endogámicos C57BL , Enfermedades Musculares/tratamiento farmacológico , Enfermedades Musculares/patología , Enfermedades Musculares/metabolismo
2.
Methods Mol Biol ; 2829: 277-286, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38951344

RESUMEN

Quantitative immunoassays, such as the traditional enzyme-linked immunosorbent assay (ELISA), are used to determine concentrations of an antigen in a matrix of unknown antigen concentration. Magnetic immunoassays, such as the Luminex xMAP technology, allow for the simultaneous detection of multiple analytes and offer heightened sensitivity, specificity, low sample volume requirements, and high-throughput capabilities. Here, we describe a quantitative immunoassay using the Luminex MAGPIX® System to determine the antigen concentration from liquid samples with unknown concentrations. In detail, we describe a newly developed assay for determining production yields of Drosophila S2-produced Marburg virus (MARV) glycoprotein in insect-cell-culture-derived supernatant. The potential applications of this assay could extend to the quantification of viral antigens in fluids derived from both in vitro and in vivo models infected with live MARV, thereby providing additional applications for virological research.


Asunto(s)
Antígenos Virales , Microesferas , Animales , Inmunoensayo/métodos , Antígenos Virales/inmunología , Antígenos Virales/análisis , Marburgvirus/inmunología , Marburgvirus/aislamiento & purificación , Drosophila , Técnicas de Cultivo de Célula/métodos , Línea Celular , Ensayo de Inmunoadsorción Enzimática/métodos
3.
Sci Adv ; 10(26): eado6798, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38941458

RESUMEN

Oral medication for ulcerative colitis (UC) is often hindered by challenges such as inadequate accumulation, limited penetration of mucus barriers, and the intricate task of mitigating excessive ROS and inflammatory cytokines. Here, we present a strategy involving sodium alginate microspheres (SAMs) incorporating M2 macrophage membrane (M2M)-coated Janus nanomotors (denominated as Motor@M2M) for targeted treatment of UC. SAM provides a protective barrier, ensuring that Motor@M2M withstands the harsh gastric milieu and exhibits controlled release. M2M enhances the targeting precision of nanomotors to inflammatory tissues and acts as a decoy for the neutralization of inflammatory cytokines. Catalytic decomposition of H2O2 by MnO2 in the oxidative microenvironment generates O2 bubbles, propelling Motor@M2M across the mucus barrier into inflamed colon tissues. Upon oral administration, Motor@M2M@SAM notably ameliorated UC severity, including inflammation mitigation, ROS scavenging, macrophage reprogramming, and restoration of the intestinal barrier and microbiota. Consequently, our investigation introduces a promising oral microsphere formulation of macrophage-biomimetic nanorobots, providing a promising approach for UC treatment.


Asunto(s)
Alginatos , Colitis Ulcerosa , Macrófagos , Microesferas , Colitis Ulcerosa/tratamiento farmacológico , Colitis Ulcerosa/metabolismo , Colitis Ulcerosa/patología , Macrófagos/metabolismo , Macrófagos/efectos de los fármacos , Animales , Administración Oral , Ratones , Alginatos/química , Humanos , Modelos Animales de Enfermedad , Especies Reactivas de Oxígeno/metabolismo , Nanopartículas/química , Sistemas de Liberación de Medicamentos , Peróxido de Hidrógeno/metabolismo
4.
Mol Pharm ; 21(7): 3407-3415, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38822792

RESUMEN

Transarterial radioembolization (TARE) is a highly effective localized radionuclide therapy that has been successfully used to treat hepatocellular carcinoma (HCC). Extensive research has been conducted on the use of radioactive microspheres (MSs) in TARE, and the development of ideal radioactive MSs is crucial for clinical trials and patient treatment. This study presents the development of a radioactive MS for TARE of HCC. These MSs, referred to as 177Lu-MS@PLGA, consist of poly(lactic-co-glycolic acid) (PLGA) copolymer and radioactive silica MSs, labeled with 177Lu and then coated with PLGA. It has an extremely high level of radiostability. Cellular experiments have shown that it can cause DNA double-strand breaks, leading to cell death. In vivo radiostability of 177Lu-MS@PLGA is demonstrated by microSPECT/CT imaging. In addition, the antitumor study has shown that TARE of 177Lu-MS@PLGA can effectively restrain tumor growth without harmful side effects. Thus, 177Lu-MS@PLGA exhibits significant potential as a radioactive MS for the treatment of HCC.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Lutecio , Microesferas , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Radioisótopos , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/radioterapia , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , Animales , Humanos , Ratones , Lutecio/química , Radioisótopos/química , Radioisótopos/administración & dosificación , Embolización Terapéutica/métodos , Línea Celular Tumoral , Ratones Endogámicos BALB C , Ratones Desnudos , Radiofármacos/química , Radiofármacos/administración & dosificación , Radiofármacos/uso terapéutico , Ensayos Antitumor por Modelo de Xenoinjerto
5.
J Nanobiotechnology ; 22(1): 372, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918811

RESUMEN

Hemangioma of infancy is the most common vascular tumor during infancy and childhood. Despite the proven efficacy of propranolol treatment, certain patients still encounter resistance or face recurrence. The need for frequent daily medication also poses challenges to patient adherence. Bleomycin (BLM) has demonstrated effectiveness against vascular anomalies, yet its use is limited by dose-related complications. Addressing this, this study proposes a novel approach for treating hemangiomas using BLM-loaded hyaluronic acid (HA)-based microneedle (MN) patches. BLM is encapsulated during the synthesis of polylactic acid (PLA) microspheres (MPs). The successful preparation of PLA MPs and MN patches is confirmed through scanning electron microscopy (SEM) images. The HA microneedles dissolve rapidly upon skin insertion, releasing BLM@PLA MPs. These MPs gradually degrade within 28 days, providing a sustained release of BLM. Comprehensive safety assessments, including cell viability, hemolysis ratio, and intradermal reactions in rabbits, validate the safety of MN patches. The BLM@PLA-MNs exhibit an effective inhibitory efficiency against hemangioma formation in a murine hemangioma model. Of significant importance, RNA-seq analysis reveals that BLM@PLA-MNs exert their inhibitory effect on hemangiomas by regulating the P53 pathway. In summary, BLM@PLA-MNs emerge as a promising clinical candidate for the effective treatment of hemangiomas.


Asunto(s)
Bleomicina , Preparaciones de Acción Retardada , Sistemas de Liberación de Medicamentos , Hemangioma , Ácido Hialurónico , Agujas , Poliésteres , Bleomicina/farmacología , Animales , Ratones , Conejos , Hemangioma/tratamiento farmacológico , Ácido Hialurónico/química , Preparaciones de Acción Retardada/química , Sistemas de Liberación de Medicamentos/métodos , Poliésteres/química , Humanos , Microesferas , Antibióticos Antineoplásicos/farmacología , Antibióticos Antineoplásicos/uso terapéutico , Antibióticos Antineoplásicos/administración & dosificación , Antibióticos Antineoplásicos/farmacocinética , Liberación de Fármacos
6.
Biosensors (Basel) ; 14(6)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38920569

RESUMEN

Traditional single nucleic acid assays can only detect one target while multiple nucleic acid assays can detect multiple targets simultaneously, providing comprehensive and accurate information. Fluorescent microspheres in multiplexed nucleic acid detection offer high sensitivity, specificity, multiplexing, flexibility, and scalability advantages, enabling precise, real-time results and supporting clinical diagnosis and research. However, multiplexed assays face challenges like complexity, costs, and sample handling issues. The review explores the recent advancements and applications of fluorescent microspheres in multiple nucleic acid detection. It discusses the versatility of fluorescent microspheres in various fields, such as disease diagnosis, drug screening, and personalized medicine. The review highlights the possibility of adjusting the performance of fluorescent microspheres by modifying concentrations and carrier forms, allowing for tailored applications. It emphasizes the potential of fluorescent microsphere technology in revolutionizing nucleic acid detection and advancing health, disease treatment, and medical research.


Asunto(s)
Técnicas Biosensibles , Microesferas , Ácidos Nucleicos , Ácidos Nucleicos/análisis , Humanos , Colorantes Fluorescentes
7.
Biosensors (Basel) ; 14(6)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38920601

RESUMEN

Optically induced dielectrophoresis (ODEP)-based microparticle sorting and separation is regarded as promising. However, current methods normally lack the downstream process for the transportation and collection of separated microparticles, which could limit its applications. To address this issue, an ODEP microfluidic chip encompassing three microchannels that join only at the central part of the microchannels (i.e., the working zone) was designed. During operation, three laminar flows were generated in the zone, where two dynamic light bar arrays were designed to sort and separate PS (polystyrene) microbeads of different sizes in a continuous manner. The separated PS microbeads were then continuously transported in laminar flows in a partition manner for the final collection. The results revealed that the method was capable of sorting and separating PS microbeads in a high-purity manner (e.g., the microbead purity values were 89.9 ± 3.7, 88.0 ± 2.5, and 92.8 ± 6.5% for the 5.8, 10.8, and 15.8 µm microbeads harvested, respectively). Overall, this study demonstrated the use of laminar flow and ODEP to achieve size-based sorting, separation, and collection of microparticles in a continuous and high-performance manner. Apart from the demonstration, this method can also be utilized for size-based sorting and the separation of other biological or nonbiological microparticles.


Asunto(s)
Electroforesis , Técnicas Analíticas Microfluídicas , Microesferas , Tamaño de la Partícula , Poliestirenos , Microfluídica
8.
ACS Appl Mater Interfaces ; 16(25): 31966-31982, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38829697

RESUMEN

Currently, postoperative infection is a significant challenge in bone and dental surgical procedures, demanding the exploration of innovative approaches due to the prevalence of antibiotic-resistant bacteria. This study aims to develop a strategy for controlled and smart antibiotic release while accelerating osteogenesis to expedite bone healing. In this regard, temperature-responsive doxycycline (DOX) imprinted bioglass microspheres (BGMs) were synthesized. Following the formation of chitosan-modified BGMs, poly N-isopropylacrylamide (pNIPAm) was used for surface imprinting of DOX. The temperature-responsive molecularly imprinted polymers (MIPs) exhibited pH and temperature dual-responsive adsorption and controlled-release properties for DOX. The temperature-responsive MIP was optimized by investigating the molar ratio of N,N'-methylene bis(acrylamide) (MBA, the cross-linker) to NIPAm. Our results demonstrated that the MIPs showed superior adsorption capacity (96.85 mg/g at 35 °C, pH = 7) than nonimprinted polymers (NIPs) and manifested a favorable selectivity toward DOX. The adsorption behavior of DOX on the MIPs fit well with the Langmuir model and the pseudo-second-order kinetic model. Drug release studies demonstrated a controlled release of DOX due to imprinted cavities, which were fitted with the Korsmeyer-Peppas kinetic model. DOX-imprinted BGMs also revealed comparable antibacterial effects against Staphylococcus aureus and Escherichia coli to the DOX (control). In addition, MIPs promoted viability and osteogenic differentiation of MG63 osteoblast-like cells. Overall, the findings demonstrate the significant potential of DOX-imprinted BGMs for use in bone defects. Nonetheless, further in vitro investigations and subsequent in vivo experiments are warranted to advance this research.


Asunto(s)
Antibacterianos , Cerámica , Doxiciclina , Microesferas , Osteogénesis , Staphylococcus aureus , Doxiciclina/farmacología , Doxiciclina/química , Antibacterianos/farmacología , Antibacterianos/química , Cerámica/química , Cerámica/farmacología , Staphylococcus aureus/efectos de los fármacos , Osteogénesis/efectos de los fármacos , Humanos , Impresión Molecular , Escherichia coli/efectos de los fármacos , Liberación de Fármacos , Quitosano/química , Quitosano/farmacología
9.
ACS Appl Mater Interfaces ; 16(25): 32566-32577, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38867413

RESUMEN

In this work, the hydroxyapatite (HA) microspheres are utilized as carriers for 8-hydroxyquinoline (8-HQ) inhibitors with a sodium alginate-silver nitrate layer (Ag-SA) added to confer chloride-responsive properties. These 8-HQ@Ag-SA-HA microspheres are subsequently integrated into poly(lactic acid) (PLA) coatings to produce biocompatible coatings. The resulting 8-HQ@Ag-SA-HA microsphere exhibits a spherical structure with a diameter of 3.16 µm. Thermogravimetric analysis indicates that the encapsulated 8-HQ inhibitors are approximately 11.83 wt %. Furthermore, the incorporation of these microspheres fills the micropores within the PLA coating, leading to a denser coating surface, enhanced wettability (contact angle value = 88°), and improved adhesion strength, thereby reinforcing the physical barrier effect. Corrosion tests reveal that the coatings exhibit increased resistance to corrosion in simulated body fluid (SBF) solutions. The released 8-HQ inhibitors in response to chloride ions form a protective layer of Mg(HQ)2, providing the coatings with self-healing properties and ensuring their durability in the SBF environment. Additionally, the cell test demonstrates a significant presence of MG-63 cells, accompanied by a low hemolysis rate of 3.81%, confirming the exceptional biocompatibility of the coatings. These findings offer valuable insights into the development of stimuli-responsive biocompatible coatings for effectively protecting Mg alloys.


Asunto(s)
Aleaciones , Cloruros , Materiales Biocompatibles Revestidos , Magnesio , Aleaciones/química , Aleaciones/farmacología , Humanos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Magnesio/química , Magnesio/farmacología , Cloruros/química , Durapatita/química , Durapatita/farmacología , Corrosión , Microesferas , Alginatos/química , Poliésteres/química
10.
ACS Appl Mater Interfaces ; 16(25): 32702-32712, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38870327

RESUMEN

Herein, we report a dual-functional flexible sensor (DFFS) using a magnetic conductive polymer composed of nickel (Ni), carbon black (CB), and polydimethylsiloxane (PDMS). The material selection for the DFFS utilizes the excellent elasticity of the PDMS matrix and the synergistic interaction between Ni and CB. The DFFS has a wide strain range of 0-170%, a high sensitivity of 74.13 (140-170%), and a low detection limit of 0.3% strain. The DFFS based on superior performance can accurately detect microstrain/microvibration, oncoming/contacting objects, and bicycle riding speed. Additionally, the DFFS can be used for comprehensive monitoring of human movements. Therefore, the DFFS of this work shows significant value for implementation in intelligent wearable devices and noncontact intelligent control.


Asunto(s)
Dimetilpolisiloxanos , Microesferas , Níquel , Hollín , Dispositivos Electrónicos Vestibles , Dimetilpolisiloxanos/química , Humanos , Níquel/química , Hollín/química , Movimiento , Conductividad Eléctrica
11.
Adv Ther ; 41(7): 2936-2952, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38833144

RESUMEN

INTRODUCTION: Hair loss is driven by multiple factors, including genetics. Androgenetic alopecia (AGA) is a condition in which treatments necessitate prolonged compliance with prescribed medications. We have developed IVL3001, a long-acting injectable (LAI) formulation of finasteride encapsulated within poly lactic-co-glycolic acid microspheres, to enhance the efficacy of the finasteride and to achieve consistent positive outcomes in adults. An open-label, sequential, single-dose phase I clinical trial was designed to evaluate the safety, pharmacokinetic (PK), and pharmacodynamic (PD) of IVL3001. METHODS: A total of 40 non-smoking, healthy adult males were divided into three cohorts where the IVL3001 group received a single subcutaneous injection of 12-36 mg IVL3001 and 1 mg finasteride (Propecia®) once daily for 28 days. The plasma concentrations of finasteride, dihydrotestosterone (DHT), and testosterone were measured using liquid chromatography-tandem mass spectrometry. The tolerability of the injections was assessed, and compartment models were developed to predict the effective dose and assess PK/PD profiles. RESULTS: IVL3001 and finasteride 1 mg tablets were well tolerated. IVL3001 showed consistent plasma concentrations without bursts or fluctuations. Consistent with its mechanism of action, IVL3001 reduced DHT levels. Simulation data showed that the administration of 12-36 mg of IVL3001 every 4 weeks achieved plasma concentrations similar to finasteride, with comparable DHT reduction. CONCLUSION: The present study represents the first clinical trial to evaluate the safety, pharmacokinetic (PK), pharmacodynamic (PD), and tolerability of finasteride long-acting injectables (LAI) in adults. The rapid onset of action sustained effective drug concentration and the prolonged half-life of IVL3001 suggest that it offers multiple benefits over conventional oral formulations in terms of therapeutic response and compliance. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT04945226.


Asunto(s)
Inhibidores de 5-alfa-Reductasa , Alopecia , Finasterida , Humanos , Finasterida/farmacocinética , Finasterida/administración & dosificación , Finasterida/efectos adversos , Alopecia/tratamiento farmacológico , Masculino , Adulto , Inhibidores de 5-alfa-Reductasa/farmacocinética , Inhibidores de 5-alfa-Reductasa/administración & dosificación , Inhibidores de 5-alfa-Reductasa/efectos adversos , Inhibidores de 5-alfa-Reductasa/farmacología , Dihidrotestosterona/farmacocinética , Dihidrotestosterona/administración & dosificación , Dihidrotestosterona/sangre , Persona de Mediana Edad , Preparaciones de Acción Retardada , Testosterona/farmacocinética , Testosterona/sangre , Inyecciones Subcutáneas , Adulto Joven , Microesferas
12.
Anal Methods ; 16(26): 4402-4408, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38904182

RESUMEN

Myocardial infarction occurs rapidly, and thus the rapid detection of cTnI levels is the key to its diagnosis. Most current assays take 10-30 min. In this study, we developed a method for accurately measuring cardiac troponin I (cTnI) levels in human sera with amplified luminescence neighborhood homogeneous assay (AlphaLISA). The method involves coupling two cTnI antibodies targeting different epitopes to the surface of carboxylated donor and acceptor beads. The final signal values were detected by the double-antibody sandwich method, and the best reaction conditions were obtained by optimizing the experimental conditions. The sensitivity, specificity, accuracy, and precision of the method were evaluated. Results showed that the method requires only 3 min to produce the results, the detection sensitivity is 27.06 ng L-1, and the measurement range is 34.56-62 500 ng L-1. cTnI-AlphaLISA has an intra-assay precision of 2.18-4.57% (<10%) and an inter-assay precision of 5.60-6.95% (<10%). The relative recovery rates are within reasonable limits. In addition, the serum assay results of the method were compared with chemiluminescence immunoassay, and the results are in agreement with one another (ρ = 0.8803; P < 0.0001). The method is expected to be developed as a routine method, but further studies and evaluations are needed.


Asunto(s)
Microesferas , Troponina I , Troponina I/sangre , Troponina I/inmunología , Humanos , Límite de Detección , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Reproducibilidad de los Resultados , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Fluoroinmunoensayo/métodos , Sensibilidad y Especificidad
13.
Environ Health Perspect ; 132(6): 64003, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38922330

RESUMEN

Mice exposed orally to microspheres showed changes in lipid and other metabolic pathways, and the particles were detected in tissues throughout the body. Changes were greater after exposure to mixed microplastics compared with polystyrene alone.


Asunto(s)
Microplásticos , Animales , Microplásticos/toxicidad , Ratones , Microesferas , Masculino , Poliestirenos/toxicidad , Administración Oral
14.
Biomed Mater ; 19(5)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38917838

RESUMEN

Sutures are commonly used in surgical procedures and have immense potential for direct drug delivery into the wound site. However, incorporating active pharmaceutical ingredients into the sutures has always been challenging as their mechanical strength deteriorates. This study proposes a new method to produce microspheres-embedded surgical sutures that offer adequate mechanical properties for effective wound healing applications. The study used curcumin, a bioactive compound found in turmeric, as a model drug due to its anti-inflammatory, antioxidant, and anti-bacterial properties, which make it an ideal candidate for a surgical suture drug delivery system. Curcumin-loaded microspheres were produced using the emulsion solvent evaporation method with polyvinyl alcohol (PVA) as the aqueous phase. The microspheres' particle sizes, drug loading (DL) capacity, and encapsulation efficiency (EE) were investigated. Microspheres were melt-extruded with polycaprolactone and polyethylene glycol via a 3D bioplotter, followed by a drawing process to optimise the mechanical strength. The sutures' thermal, physiochemical, and mechanical properties were investigated, and the drug delivery and biocompatibility were evaluated. The results showed that increasing the aqueous phase concentration resulted in smaller particle sizes and improved DL capacity and EE. However, if PVA was used at 3% w/v or below, it prevented aggregate formation after lyophilisation, and the average particle size was found to be 34.32 ± 12.82 µm. The sutures produced with the addition of microspheres had a diameter of 0.38 ± 0.02 mm, a smooth surface, minimal tissue drag, and proper tensile strength. Furthermore, due to the encapsulated drug-polymer structure, the sutures exhibited a prolonged and sustained drug release of up to 14 d. Microsphere-loaded sutures demonstrated non-toxicity and accelerated wound healing in thein vitrostudies. We anticipate that the microsphere-loaded sutures will serve as an excellent biomedical device for facilitating wound healing.


Asunto(s)
Materiales Biocompatibles , Curcumina , Ensayo de Materiales , Microesferas , Tamaño de la Partícula , Alcohol Polivinílico , Suturas , Cicatrización de Heridas , Cicatrización de Heridas/efectos de los fármacos , Curcumina/química , Curcumina/farmacología , Materiales Biocompatibles/química , Alcohol Polivinílico/química , Animales , Resistencia a la Tracción , Sistemas de Liberación de Medicamentos , Polietilenglicoles/química , Humanos , Poliésteres/química
15.
J Microencapsul ; 41(5): 375-389, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38945166

RESUMEN

AIMS: This study aimed to encapsulate natural killer (NK) cells in a hydrogel to sustain their function within the hypoxic tumour microenvironments. METHODS: An alginate-gelatine hydrogel was generated via electrospray technology. Hydrogel biocompatibility was assessed through cell counting kit-8 and Live/Dead assays to ascertain cell. Moreover, we analysed lactate dehydrogenase assays to evaluate the cytotoxicity against tumours and utilised RT-qPCR to analyse cytokine gene level. RESULTS: Alginate and gelatine formed hydrogels with diameters ranging from 489.2 ± 23.0 µm, and the encapsulation efficiency was 34.07 ± 1.76%. Encapsulated NK cells exhibited robust proliferation and tumour-killing capabilities under normoxia and hypoxia. Furthermore, encapsulation provided a protective shield against cell viability under hypoxia. Importantly, tumour-killing cytotoxicity through cytokines upregulation such as granzyme B and interferon-gamma was preserved under hypoxia. CONCLUSION: The encapsulation of NK cells not only safeguards their viability but also reinforces anticancer capacity, countering the inhibition of activation induced by hypoxia.


Asunto(s)
Alginatos , Proliferación Celular , Gelatina , Hidrogeles , Células Asesinas Naturales , Microesferas , Alginatos/química , Alginatos/farmacología , Hidrogeles/química , Hidrogeles/farmacología , Humanos , Proliferación Celular/efectos de los fármacos , Gelatina/química , Supervivencia Celular/efectos de los fármacos , Hipoxia de la Célula/efectos de los fármacos , Encapsulación Celular/métodos , Animales , Microambiente Tumoral/efectos de los fármacos , Línea Celular Tumoral , Ratones
16.
Analyst ; 149(14): 3765-3772, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38842353

RESUMEN

Molecularly imprinted polymer (MIP)-based chromatographic separation materials, owing to their advantages of unique selectivity, low cost, suitable reproducibility, and acceptable stability, have attracted a great deal of research in different fields. In this investigation, a new type of MIP-coated silica (MIP/SiO2) separation material was developed using sulfamethoxazole as a template; the specific recognition ability of MIP and appropriate physicochemical properties (abundant Si-OH, suitable pore structure, good stability, etc.) of SiO2 microbeads were combined. The MIP/SiO2 separation materials were characterized carefully. Then, various compounds (such as sulfonamides, ginsenosides, nucleosides, and several pesticides) were used to comprehensively evaluate the chromatographic performances of the MIP/SiO2 column. Furthermore, the chromatographic performances of the MIP/SiO2 column were compared with those of other separation materials (such as non-imprinted polymer-coated silica, C18/SiO2, and bare silica) packed columns. The resolution value of all measured compounds was more than 1.51. The column efficiencies of 13 510 plates per meter (N m-1) for sulfamethoxazole, 11 600 N m-1 for ginsenoside Rd, and 10 510 N m-1 for 2'-deoxyadenosine were obtained. The acceptable results verified that the MIP/SiO2 column can be applied to separate highly polar drugs such as sulfonamides, ginsenosides, nucleosides, and pesticides.


Asunto(s)
Microesferas , Polímeros Impresos Molecularmente , Dióxido de Silicio , Dióxido de Silicio/química , Cromatografía Líquida de Alta Presión/métodos , Polímeros Impresos Molecularmente/química , Ginsenósidos/química , Ginsenósidos/análisis , Ginsenósidos/aislamiento & purificación , Impresión Molecular/métodos , Nucleósidos/química , Nucleósidos/aislamiento & purificación , Nucleósidos/análisis , Plaguicidas/análisis , Plaguicidas/química , Plaguicidas/aislamiento & purificación , Polímeros/química
17.
Int J Biol Macromol ; 273(Pt 2): 132899, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38844275

RESUMEN

Despite the widespread utilization of nano silver composites in the domain of catalytic hydrogenation of aromatic pollutants in wastewater, certain challenges persist, including the excessive consumption of chemical reagents during the preparation process and the difficulty in recycling. In this study, silver ions were reduced in-situ by taking advantage of the adsorptive and reducing capacities of hydroxyls and amino groups on lignin porous microspheres (LPMs) under mild ultrasonic conditions, and lignin porous microspheres loaded with silver nanoparticles (Ag@LPMs) were conveniently prepared. Ag@LPMs had excellent catalytic and cycling performances for p-nitrophenol (4-NP), methylene blue (MB) and methyl orange (MO). The 4-NP could be completely reduced to 4-AP within 155 s under the catalysis of Ag@LPMs, with a pseudo-first-order kinetic constant of 1.28 min-1. Furthermore, Ag@LPMs could still complete the catalytic reduction of 4-NP within 10 min after five cycles. Ag@LPMs with the particle size ranging from 100 to 200 µm conferred ease of recycling, and the porous structure effectively resolved the issue of sluggish mass transfer encountered during the catalytic process. At the same time, the binding force of nano silver and LPMs obtained by ultrasonic was stronger than that of heating, so the materials prepared by ultrasonic had better cycling performance. Silver ions concentration and pH value in the preparation process affected the catalytic performance of Ag@LPMs, 50 mmol/L Ag+ and pH value of 7 turned out to be the optimization conditions.


Asunto(s)
Lignina , Nanopartículas del Metal , Microesferas , Plata , Lignina/química , Plata/química , Catálisis , Porosidad , Nanopartículas del Metal/química , Nitrofenoles/química , Oxidación-Reducción , Cinética
18.
Int J Biol Macromol ; 273(Pt 1): 132964, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38852719

RESUMEN

There is a growing interest in developing highly viscous lipid foods using plant protein and polysaccharide gum-based emulsion technology. However, gaps remain in understanding the rheological, microstructural, and digestive properties of plant proteins like soybean protein isolate (SPI) in combination with various gums. This study investigates how combining SPI and peach gum (PG) affects rheology and lipolysis of oil-in-water (O/W) emulsions containing 20 wt% soybean oil. Emulsions with varying SPI and PG compositions including SPI-PG single and SPI/PG mixed droplet systems were prepared. Heating induced alterations in viscosity (e.g., SPI-PG from 14.88 to 90.27 Pa·s and SPI/PG from 9.66 to 85.32 Pa·s) and microstructure revealing aggregate formation at oil-water interface. The viscosity decreased significantly from the oral to intestinal phase (SPI-PG: 28.10 to 0.19 Pa·s, SPI/PG: 21.27 to 0.10 Pa·s). These changes affected lipid digestion, notably in SPI-PG and SPI/PG emulsions where a compact interface hindered lipolysis during digestion. Interestingly, free fatty acid (FFA) release during small intestinal phase followed a different order: SPI (82.51 %) > SPI-PG (70.77 %) > SPI/PG (63.60 %) > PG (56.09 %). This study provides insights into creating highly viscous O/W spreads with improved rheology, stability, and delayed lipid digestion, offering potential benefits in food product formulation.


Asunto(s)
Emulsiones , Microesferas , Gomas de Plantas , Reología , Proteínas de Soja , Agua , Emulsiones/química , Proteínas de Soja/química , Agua/química , Gomas de Plantas/química , Viscosidad , Aceite de Soja/química , Lipólisis
19.
Int J Biol Macromol ; 273(Pt 1): 132998, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38866290

RESUMEN

Paclitaxel, a diterpenoid isolated from the bark of Taxus wallichiana var. chinensis (Pilger) Florin, is currently showing significant therapeutic effects against a variety of cancers. Baccatin III (Bac) and 10-Deacetylbaccatin III (10-DAB) are in great demand as important precursors for the synthesis of paclitaxel. This work aims to develop a simple, rapid and highly selective, safe, and non-polluting molecularly imprinted material for 10-DAB and Bac enrichment. In this study, we innovatively prepared molecularly imprinted materials with nanocellulose aerogel microspheres and 2-vinylpyridine (2-VP) as a bifunctional monomer, and 10-DAB and Bac as bis-template molecules. In particular, functionalized nanocellulose dual-template molecularly imprinted aerogel microsphere (FNCAG-DMIM) were successfully synthesized by the bifunctional introduction of functional nanocellulose aerogel microsphere (FNCAG) modified with Polyethyleneimine (PEI) as a carrier and functional monomer, which provided a large number of recognition sites for bimodal molecules. FNCAG-DMIM showed high specificity for 10-DAB and Bac specific assays. Under the optimal experimental conditions, the adsorption capacities of FNCAG-DMIM for 10-DAB and Bac reached 52.27 mg g-1 and 53.81 mg g-1, respectively. In addition, it showed good reliability and practicality in the determination of real samples. The present study extends the research on the synthesis of natural functional monomers by molecularly imprinted materials and opens up new horizons for the targeted isolation of plant compounds by dual-template molecularly imprinted materials.


Asunto(s)
Celulosa , Geles , Microesferas , Impresión Molecular , Celulosa/química , Celulosa/análogos & derivados , Geles/química , Impresión Molecular/métodos , Adsorción , Taxoides/química
20.
Int J Biol Macromol ; 273(Pt 1): 133117, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38871098

RESUMEN

Removing p-nitrophenol (PNP) from water resources is crucial due to its significant threat to the environment and human health. Herein, imidazolium ionic liquids with short/long alkyl chain ([C2VIm]Br and [C8VIm]Br) modified cellulose microspheres (MCC-[C2VIm]Br and MCC-[C8VIm]Br) were synthesized by radiation method. To examine the impact of adsorbent hydrophilicity on adsorption performance, batch and column experiments were conducted for PNP adsorption. The MCC-[C2VIm]Br and MCC-[C8VIm]Br, with an equivalent molar import amount of ionic liquids, exhibited maximum adsorption capacities of 190.84 mg/g and 191.20 mg/g for PNP, respectively, and the adsorption equilibrium was reached within 30 min. Both adsorbents displayed exceptional reusability. Integrating the findings from XPS and FTIR analyses, and AgNO3 identification, the suggested adsorption mechanism posited that the adsorbents engaged with PNP through ion exchange, hydrogen bonds and π-π stacking. Remarkably, the hydrophobic MCC-[C8VIm]Br exhibited superior selectivity for PNP than the hydrophilic MCC-[C2VIm]Br, while had little effect on adsorption capacity and rate. MCC-[C8VIm]Br-2 with high grafting yield increased the adsorption capacity to 327.87 mg/g. Moreover, MCC-[C8VIm]Br-2 demonstrated efficient PNP removal from various real water samples, and column experiments illustrated its selective capture of PNP from groundwater. The promising adsorption performance indicates that MCC-[C8VIm]Br-2 holds potential for PNP removal from wastewater.


Asunto(s)
Celulosa , Imidazoles , Líquidos Iónicos , Microesferas , Nitrofenoles , Contaminantes Químicos del Agua , Purificación del Agua , Celulosa/química , Nitrofenoles/química , Líquidos Iónicos/química , Adsorción , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/aislamiento & purificación , Imidazoles/química , Purificación del Agua/métodos , Agua/química , Interacciones Hidrofóbicas e Hidrofílicas , Cinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...