Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 21.208
1.
Zhonghua Yi Xue Za Zhi ; 104(21): 1979-1986, 2024 Jun 04.
Article Zh | MEDLINE | ID: mdl-38825941

Objective: To analyze the efficacy of alternate titanium clip closure in preventing postoperative complications for patients with gastric mucosal lesions after endoscopic submucosal dissection (ESD). Methods: Clinical data of patients with gastric mucosal lesions who underwent ESD in the Department of Gastroenterology, Zhongda Hospital, Southeast University, were retrospectively collected from January 1, 2013 to August 31, 2023. According to the postoperative wound closure status, the patients were divided into completely closed group (complete closure of ESD wounds using alternate titanium clip closure), partially closed group (partial closure of ESD wounds), and unclosed group (without use of clips for treatment of ESD wounds). The incidence of postoperative complications as well as wound healing at 1 month and 3 months after surgery were compared among three groups, and the factors related to delayed bleeding after ESD for gastric mucosal lesions were analyzed through multiple logistic regression analysis. Results: A total of 846 patients were included, 430 cases in the completely closed group, including 300 males and 130 females, age [M (Q1, Q3)] was 65(56, 72) years old; one hundred and nine cases in unclosed group, including 78 males and 31 females, aged 66 (60, 71) years; and 307 cases in the partially closed group, including 214 males and 93 females, aged 66 (59, 71) years. The difference in the rate of delayed postoperative bleeding between the completely closed group [2.1% (9/430)] and the unclosed group [5.5% (6/109)] was not statistically significant (P=0.072), but both were lower than that of the partially closed group [9.4% (29/307), P<0.05)]. Further stratified analysis showed that, for the lesions located in the lower 1/3 of the stomach, the rate of postoperative bleeding was lower in the completely closed group than in the partially closed and unclosed groups [0.9% (2/222) vs 11.4% (4/35) vs 9.5% (7/74), respectively, P<0.001]. For lesions≥50 mm in length, the rate of postoperative bleeding was lower in the completely closed group than that in the partially closed and unclosed group[0 vs 11.8% (2/17) vs 20.5% (15/73), respectively, P=0.004]. The incidence of postoperative abdominal pain in the completely closed group [84.2% (363/430)] was lower than that in the unclosed group [97.2% (106/109)] and the partially closed group [95.4% (293/307), both P<0.001)]. The score of postoperative abdominal pain in the completely closed group [0 (0, 1)], was lower than that in the unclosed group [3 (2, 3)], and that in the partially closed group [2 (1, 3)] (both P<0.001). The wound healing rate of the completely closed group [80% (176/220)] was higher than that of the unclosed group [52.3% (33/63)] and the partially closed group [52.2% (83/159)] at 1 month postoperatively (both P<0.001); the healing rate of all three groups reached 100% at 3 months postoperatively. Multiple logistic regression analysis showed that the presence of ulcers or scars on the surface of the lesion (OR=2.930, 95%CI:1.503-5.712, P=0.002), and the diameter (OR=1.031, 95%CI:1.015-1.047,P<0.001) were related factors for postoperative bleeding. Conclusions: The alternate titanium clip closure surgery can reduce postoperative abdominal pain and shorten wound healing time in patients with gastric mucosal lesions after ESD surgery. The risk of postoperative bleeding can be reduced for lesions with a diameter≥50 mm and located in the lower 1/3 of the stomach.


Endoscopic Mucosal Resection , Gastric Mucosa , Postoperative Complications , Humans , Endoscopic Mucosal Resection/adverse effects , Endoscopic Mucosal Resection/methods , Male , Aged , Female , Gastric Mucosa/surgery , Postoperative Complications/prevention & control , Middle Aged , Surgical Instruments , Stomach Neoplasms/surgery , Titanium , Wound Healing , Gastroscopy
2.
Sultan Qaboos Univ Med J ; 24(2): 268-271, 2024 May.
Article En | MEDLINE | ID: mdl-38828237

This technical note aimed to present a straigthforward method for harvesting quadriceps tendon autografts with the use of a simple vaginal speculum and direct visualisation of a scope. Anterior cruciate ligament reconstruction with quadriceps tendon autografts has gained popularity in recent years, with many harvesting techniques that use different harvesting systems available on the market. These techniques vary from transverse to longitudinal skin incisions and from open to minimally invasive approaches and have a learning curve, as with the majority of surgical procedures. The technique proposed in this technical note is minimally invasive, can be easily reproduced by any surgeon irrespective of their experience, has a short learning curve, requires no additional cost or technical support during the procedure and creates a stable working space that allows for freedom of manipulation of surgical instruments and the arthroscope.


Anterior Cruciate Ligament Reconstruction , Humans , Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament Reconstruction/instrumentation , Female , Autografts , Tissue and Organ Harvesting/methods , Tissue and Organ Harvesting/instrumentation , Tendons , Quadriceps Muscle , Transplantation, Autologous/methods , Surgical Instruments
3.
Medicine (Baltimore) ; 103(23): e38451, 2024 Jun 07.
Article En | MEDLINE | ID: mdl-38847672

Although endoscopic forceps biopsy is the gold standard for early gastric cancer (EGC) diagnosis, the method can cause endoscopic resection of specimens and histological discrepancies. This study aims to examine the risk factors for histological discrepancies in EGC and long-term clinical outcomes. This retrospective study included patients diagnosed with differentiated-type EGC using forceps biopsy. Patients without histological discrepancies and with undifferentiated types in endoscopic resection histology were categorized into the concordant and discordant groups, respectively. Clinical characteristics and long-term outcomes related to histological discrepancies were analyzed. A total of 957 lesions from 936 patients were enrolled. An overall discrepancy rate of 8.7% was confirmed, with an undifferentiated-type discrepancy of 5.5%. The discordant group showed a higher tendency for lesions to be located in the upper third region, to have whitish discoloration, and to undergo a greater number of biopsies compared with the concordant group. Multivariate analysis confirmed that lesion location in the upper third region (odds ratio [OR]: 2.125; 95% confidence interval [CI]: 1.032-5.277; P = .041) and whitish surface discoloration (OR: 13.615; 95% CI: 6.028-28.728; P = .001) were significantly correlated with histologic discrepancy. Compared with the concordant group, the discordant group had a lower curative resection rate, but no differences were observed in complications, local recurrence, or survival rates. Upper third location and whitish discoloration were risk factors for the histologic discrepancy between differentiated and undifferentiated types in patients with EGC. For curative resections performed in patients with EGC and histologic discrepancies and without additional treatment, careful follow-up is possible.


Stomach Neoplasms , Humans , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Female , Male , Retrospective Studies , Middle Aged , Risk Factors , Aged , Biopsy/methods , Surgical Instruments , Gastroscopy/methods , Early Detection of Cancer/methods , Endoscopic Mucosal Resection/methods
4.
Acta Neurochir (Wien) ; 166(1): 253, 2024 Jun 07.
Article En | MEDLINE | ID: mdl-38847921

BACKGROUND/PURPOSE: Several periprocedural adjuncts for elective surgical aneurysm treatment have been introduced over the last 20 years to increase safety and efficacy. Besides the introduction of IONM in the late-1990s, ICG-videoangiography (ICG-VAG) since the mid-2000s and intraoperative CT-angiography/-perfusion (iCT-A/-P) since the mid-2010s are available. We aimed to clarify whether the introduction of ICG-VAG and iCT-A/-P resulted in our department in a stepwise improvement in the rate of radiologically detected postoperative ischemia, complete aneurysm occlusion and postoperative new deficits. METHODS: Patients undergoing microsurgical clip occlusion for unruptured anterior circulation aneurysms between 2000 and 2019 were included, with ICG-VAG since 2009 and iCT-A/-P (for selected cases) since 2016. Baseline characteristics and treatment-related morbidity/outcome focusing on differences between the three distinct cohorts (cohort-I: pre-ICG-VAG-era, cohort-II: ICG-VAG-era, cohort-III: ICG-VAG&iCT-A/-P-era) were analyzed. RESULTS: 1391 patients were enrolled (n = 74 were excluded), 779 patients were interventionally treated, 538 patients were surgically clipped by a specialized vascular team (cohort-I n = 167, cohort-II n = 284, cohort-III n = 87). Aneurysm size was larger in cohort-I (8.9 vs. 7.5/6.8 mm; p < 0.01) without differences concerning age (mean:55years), gender distribution (m: f = 1:2.6) and aneurysm location (MCA:61%, ICA:18%, ACA/AcomA:21%). There was a stepwise improvement in the rate of radiologically detected postoperative ischemia (16.2vs.12.0vs.8.0%; p = 0.161), complete aneurysm occlusion (68.3vs.83.6vs.91.0%; p < 0.01) and postoperative new deficits (10.8vs.7.7vs.5.7%; p = 0.335) from cohort-I to -III. After a mean follow-up of 12months, a median modified Rankin scale of 0 was achieved in all cohorts. DISCUSSION: Associated with periprocedural technical achievements, surgical outcome in elective anterior circulation aneurysm surgery has improved in our service during the past 20 years.


Brain Ischemia , Intracranial Aneurysm , Postoperative Complications , Humans , Intracranial Aneurysm/surgery , Intracranial Aneurysm/diagnostic imaging , Male , Female , Middle Aged , Postoperative Complications/etiology , Aged , Brain Ischemia/prevention & control , Brain Ischemia/etiology , Brain Ischemia/diagnostic imaging , Elective Surgical Procedures/methods , Neurosurgical Procedures/methods , Surgical Instruments , Adult , Treatment Outcome , Cerebral Angiography/methods , Retrospective Studies , Microsurgery/methods , Computed Tomography Angiography/methods
6.
Folia Med (Plovdiv) ; 66(2): 235-242, 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38690819

INTRODUCTION: Tooth extraction is still one of the most common dental procedures, routinely performed for a variety of reasons. Tooth extraction forceps and elevators are well-known extraction instruments which have been the standard in tooth extraction procedures for well over a hundred years. Physics forceps are one possible alternative, aiming to perform less traumatic and more predictable extractions.


Surgical Instruments , Tooth Extraction , Humans , Tooth Extraction/instrumentation , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Female , Male , Adult , Middle Aged , Young Adult , Aged
7.
PLoS One ; 19(5): e0302737, 2024.
Article En | MEDLINE | ID: mdl-38696516

BACKGROUND: As advancements in surgical instruments and techniques continue to evolve, minimally invasive surgery has become increasingly preferred as a means of reducing patient pain and recovery time. However, one major challenge in performing minimally invasive surgery for early gastrointestinal cancer is accurately identifying the location of the lesion. This is particularly difficult when the lesion is confined to the lumen of the intestine and cannot be visually confirmed from the outside during surgery. In such cases, surgeons must rely on CT or endoscopic imaging to locate the lesion. However, if the lesion is difficult to identify with these images or if the surgeon has less experience, it can be challenging to determine its precise location. This can result in an excessive resection margin, deviating from the goal of minimally invasive surgery. To address this challenge, researchers have been studying the development of a marker for identifying the lesion using a radio-frequency identification (RFID) system. One proposed method for clinical application of this detection system is to attach an RFID tag to an endoscopic hemostatic clip and fix it to the intended position, providing a stable marker for the inner wall of the organ. This approach has the potential to improve the accuracy and effectiveness of minimally invasive surgery for early gastrointestinal cancer. METHODS: In the development of a marker for identifying gastrointestinal lesions using a radio-frequency identification (RFID) system, the shape of the clip and suitable materials for attaching the RFID tag were determined through finite element method (FEM) analysis. A prototype of the clip was then fabricated and ex-vivo experiments were conducted using porcine intestine to evaluate the stability of the clip in relation to its position. To further evaluate the performance of the RFID-integrated clip in vivo, the clip was placed in the gastric wall of the stomach of anesthetized porcine using an endoscopic instrument. The clip was then detected using a RFID detector designed for laparoscopic approach. And later, the accuracy of detection was confirmed by incising the lesion. RESULTS: The design and fabrication of a clip with varying thicknesses using STS316 and STS304 stainless steel were accomplished using the results of finite element method analysis. The stability of the clip was evaluated through ex-vivo experiments, showing it to be a viable option. In-vivo experiments were performed on anesthetized porcine, in which the RFID-integrated clip was placed in the gastric wall and detected using a custom-made RFID detector. The resection margin, measured at about 30 mm from the detector position, was accomplished with low error. These findings indicate the feasibility and efficacy of using an RFID-integrated clip as a marker in minimally invasive surgery for the identification of gastrointestinal lesions. CONCLUSIONS: The study evaluated the feasibility of using stainless steel clips for lesion detection in endoscopic surgery using computer-aided engineering analysis and ex-vivo experimentation. Results showed that STS304 was suitable for use while STS316L was not. The ex-vivo experiments revealed that the clip holding force and tissue retention length varied depending on the location of attachment. In-vivo experiments confirmed the accuracy and usefulness of the RFID lesion detection system. However, challenges remain for its use in clinical field, such as ensuring the stability of the clip and the safe attachment of the RFID tag, which requires further research for commercialization.


Laparoscopy , Surgical Instruments , Laparoscopy/methods , Laparoscopy/instrumentation , Animals , Swine , Radio Frequency Identification Device/methods , Humans
8.
Prog Brain Res ; 285: 115-126, 2024.
Article En | MEDLINE | ID: mdl-38705711

The only instruments for opening the cranium considered in this chapter are drills, and in some cases facilitated with a special chisel called a lenticular. There were two kinds of trepan. The modiolus was the Latin name for a crown trepan which had a circular base with teeth which sawed a hole. Then there were the non-penetrating trepans which had a bit shaped to prevent unwanted penetration. They made small openings which could be joined by chisels to remove altogether larger areas of bone than were accessible to modioli. They were the favored instrument from the ancient world up to the Renaissance. At the beginning of the Renaissance, there was a move toward greater use of crown trepans and various methods were applied to stop them sinking too far inward. These included wings in the outer wall and changing the shape of the bit from cylindrical to conic. In time preferences returned to the cylindrical shape and larger diameters. There was also two instruments called lenticulars, the illustrations of which have been confused in the literature. It is now clear that the Roman instrument was shaped to cut the cranium and minimize the need for trepanation. The Renaissance instrument had a different shape and was used to smooth rough bone edges and excise spicules penetrating the meninges. They were simply two different instruments to which the same name was applied.


Surgical Instruments , Surgical Instruments/history , History, Ancient , Humans , History, Medieval , History, 16th Century , History, 15th Century , Skull/anatomy & histology , Trephining/history , Trephining/instrumentation
9.
Prog Brain Res ; 285: 157-178, 2024.
Article En | MEDLINE | ID: mdl-38705715

The chapter begins with also an outline of the characteristics of four surgeons who changed the direction of thinking and hence of practice. This is followed by a review of the changing ideas which governed surgical practice. Chapter "Two surgical instruments" by Jeremy C. Ganz has examined the uses of drills and lenticulars. In this chapter there is an appraisal of the other instruments used during cranial surgery and how their use related to changing ideas. Finally, there is a concluding section which ties all these elements together.


Surgical Instruments , Humans , History, 20th Century , History, 19th Century , Neurosurgery , Neurosurgical Procedures
10.
Neurosciences (Riyadh) ; 29(2): 90-95, 2024 May.
Article En | MEDLINE | ID: mdl-38740406

OBJECTIVES: To investigate the factors that contribute to the development of cerebral edema after aneurysm clipping in individuals with aneurysmal subarachnoid hemorrhage (aSAH). METHODS: A total of 232 patients with aSAH caused by rupture and treated with aneurysm clipping were included in the retrospective analysis of clinical data. Postoperatively, the participants were categorized into two groups based on the presence or absence of cerebral edema: a complication group (n=33) and a non-complication group (n=199).A comparison was made between the overall data of the 2 groups. RESULTS: In the complication group, there were higher proportions of patients experiencing recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, World Federation of Neurosurgical Societies (WFNS) grade II, Hunt-Hess grade III-IV, concomitant hypertension, duration from onset to operation ≥12 h, and concomitant hematoma compared to the non-complication group (p<0.05). Cerebral edema after aneurysm clipping was associated with several risk factors including repeated bleeding, aneurysm in the back of the brain, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, simultaneous high blood pressure and hematoma, and a duration of at least 12 hours from the start of symptoms to the surgical procedure (p<0.05). CONCLUSION: In patients with aSAH, the risk of cerebral edema after aneurysm clipping is increased by recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, concomitant hypertension and hematoma, and duration of ≥12 h from onset to operation.


Brain Edema , Subarachnoid Hemorrhage , Humans , Subarachnoid Hemorrhage/surgery , Subarachnoid Hemorrhage/complications , Male , Female , Middle Aged , Brain Edema/etiology , Risk Factors , Retrospective Studies , Adult , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Intracranial Aneurysm/surgery , Intracranial Aneurysm/complications , Neurosurgical Procedures/adverse effects , Surgical Instruments/adverse effects , Aneurysm, Ruptured/surgery , Aneurysm, Ruptured/complications
15.
Int J Med Robot ; 20(3): e2640, 2024 Jun.
Article En | MEDLINE | ID: mdl-38794828

BACKGROUND: Accurately estimating the 6D pose of snake-like wrist-type surgical instruments is challenging due to their complex kinematics and flexible design. METHODS: We propose ERegPose, a comprehensive strategy for precise 6D pose estimation. The strategy consists of two components: ERegPoseNet, an original deep neural network model designed for explicit regression of the instrument's 6D pose, and an annotated in-house dataset of simulated surgical operations. To capture rotational features, we employ an Single Shot multibox Detector (SSD)-like detector to generate bounding boxes of the instrument tip. RESULTS: ERegPoseNet achieves an error of 1.056 mm in 3D translation, 0.073 rad in 3D rotation, and an average distance (ADD) metric of 3.974 mm, indicating an overall spatial transformation error. The necessity of the SSD-like detector and L1 loss is validated through experiments. CONCLUSIONS: ERegPose outperforms existing approaches, providing accurate 6D pose estimation for snake-like wrist-type surgical instruments. Its practical applications in various surgical tasks hold great promise.


Neural Networks, Computer , Surgical Instruments , Wrist , Humans , Wrist/surgery , Equipment Design , Biomechanical Phenomena , Algorithms , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Imaging, Three-Dimensional/methods , Rotation , Reproducibility of Results , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods , Regression Analysis
16.
PLoS One ; 19(5): e0292207, 2024.
Article En | MEDLINE | ID: mdl-38787830

BACKGROUND: Speculum lubrication may help to reduce the pain experienced during Pap-smear collection and hence increase uptake of cervical cancer screening and repeat testing, but there are fears of its interference with cytological results. AIM: To determine and compare the adequacy of cervical cytology smears and the mean pain scores of women undergoing cervical cancer screening with or without speculum lubrication. METHODS: This was a randomised controlled study of 132 women having cervical cancer screening at a tertiary hospital in Nigeria. Sixty-six participants were randomly assigned to the 'Gel' and 'No Gel' groups, respectively. Pap smears were collected from each participant with a lubricated speculum ('Gel group') or a non-lubricated speculum ('No Gel group'). The primary outcome measures were the proportion of women with unsatisfactory cervical cytology smears and the mean numeric rating scale pain scores, while the secondary outcome measures were the proportion of women who were willing to come for repeat testing and the cytological diagnosis of Pap-smear results. RESULTS: The baseline socio-demographic variables were similar in both groups. There was no significant difference in the proportion of unsatisfactory cervical smear results between the two groups (13.6% vs. 21.2%, p = 0.359). However, the mean pain scores were significantly lower in the gel group than in the no gel group (45.04 vs. 87.96; p<0.001). An equal proportion of the participants in each group (90.9% vs. 90.9%; p > 0.999) were willing to come for repeat cervical smears in the future. CONCLUSION: Speculum lubrication did not affect the adequacy of cervical smears but significantly reduced the pain experienced during pap smear collection. Also, it did not significantly affect the willingness to come for repeat cervical smears in the future. TRIAL REGISTRATION: The trial was registered with the Pan-African Clinical Trial Registry with a unique identification and registration number: PACTR2020077533364675.


Early Detection of Cancer , Lubrication , Papanicolaou Test , Uterine Cervical Neoplasms , Vaginal Smears , Humans , Female , Uterine Cervical Neoplasms/diagnosis , Vaginal Smears/methods , Adult , Early Detection of Cancer/methods , Middle Aged , Double-Blind Method , Surgical Instruments
17.
J Surg Orthop Adv ; 33(1): 1-4, 2024.
Article En | MEDLINE | ID: mdl-38815069

Surgical scissors form an essential part of both basic and specialty surgical sets. Their prime function is to cut tissues. They are also used for blunt dissection/development of tissue planes and piercing tissues. A wide variety of scissors are available for use in practice. This review article briefly describes common surgical scissors in orthopaedic use. The basic construct, biomechanics, types, their identification, specific uses, and care aspects are also discussed. A surgeon should be aware of the different types of scissors, their biomechanical features, and specific uses, as they are an important tool in his/her armamentarium. (Journal of Surgical Orthopaedic Advances 33(1):001-004, 2024).


Surgical Instruments , Humans , Orthopedic Procedures/instrumentation , Equipment Design , Biomechanical Phenomena
18.
Clin Neurol Neurosurg ; 241: 108304, 2024 06.
Article En | MEDLINE | ID: mdl-38718706

OBJECTIVE: Tubular retractors are increasingly used due to their low complication rates, providing easier access to lesions while minimizing trauma from brain retraction. Our study presents the most extensive series of cases performed by a single surgeon aiming to assess the effectiveness and safety of a transcortical-transtubular approach for removing intracranial lesions. METHODS: We performed a retrospective review of patients who underwent resection of an intracranial lesion with the use of tubular retractors. Electronic medical records were reviewed for patient demographics, preoperative clinical deficits, diagnosis, preoperative and postoperative magnetic resonance imaging (MRI) scans, lesion characteristics including location, volume, extent of resection (EOR), postoperative complications, and postoperative deficits. RESULTS: 112 transtubular resections for intracranial lesions were performed. Patients presented with a diverse number of pathologies including metastasis (31.3 %), GBM (21.4 %), and colloid cysts (19.6 %) The mean pre-op lesion volume was 14.45 cm3. A gross total resection was achieved in 81 (71.7 %) cases. Seventeen (15.2 %) patients experienced early complications which included confusion, short-term memory difficulties, seizures, meningitis and motor and visual deficits. Four (3.6 %) patients had permanent complications, including one with aphasia and difficulty finding words, another with memory loss, a third with left-sided weakness, and one patient who developed new-onset long-term seizures. Mean post-operative hospitalization length was 3.8 days. CONCLUSION: Tubular retractors provide a minimally invasive approach for the extraction of intracranial lesions. They serve as an efficient tool in neurosurgery, facilitating the safe resection of deep-seated lesions with minimal complications.


Brain Neoplasms , Minimally Invasive Surgical Procedures , Neurosurgical Procedures , Postoperative Complications , Humans , Male , Female , Middle Aged , Adult , Brain Neoplasms/surgery , Brain Neoplasms/diagnostic imaging , Aged , Retrospective Studies , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Neurosurgical Procedures/methods , Postoperative Complications/epidemiology , Young Adult , Aged, 80 and over , Treatment Outcome , Adolescent , Surgical Instruments , Magnetic Resonance Imaging
19.
Best Pract Res Clin Gastroenterol ; 69: 101900, 2024 Mar.
Article En | MEDLINE | ID: mdl-38749581

Despite the evolution in tools and techniques, perforation is still one of the most pernicious adverse events of therapeutic endoscopy with potentially huge consequences. As advanced endoscopic resection techniques are worldwide spreading, endoscopists must be ready to manage intraprocedural perforations. In fact, immediate endoscopic closure through a prompt diagnosis represents the first-line option, saving patients from surgery, long hospitalizations and worse outcomes. Traditional and novel endoscopic closure modalities, including clips, suturing devices, stents and vacuum therapy, are increasingly expanding the therapeutic armamentarium for closing these defects. Nevertheless, available literature on this topic is currently limited. In this review our goal is to give an overview on the management of perforations occurring during endoscopic resections, with particular attention to characteristics, advantages, disadvantages and new horizons of endoscopic closure tools.


Intestinal Perforation , Humans , Intestinal Perforation/etiology , Intestinal Perforation/surgery , Intestinal Perforation/therapy , Intraoperative Complications/etiology , Intraoperative Complications/therapy , Negative-Pressure Wound Therapy/adverse effects , Stents , Surgical Instruments , Suture Techniques/adverse effects , Treatment Outcome , Practice Guidelines as Topic
20.
BMC Musculoskelet Disord ; 25(1): 373, 2024 May 11.
Article En | MEDLINE | ID: mdl-38730376

INTRODUCTION: An acute Achilles tendon rupture represents a common tendon injury, and its operative methods have been developed over the years. This study aimed to quantify the learning curve for the minimally invasive acute Achilles tendon rupture repair. METHODS: From May 2020 to June 2022, sixty-seven patient cases who received minimally invasive tendon repair were reviewed. Baseline data and operative details were collected. The cumulative summation (CUSUM) control chart was used for the learning curve analyses. Achilles tendon rupture score (ATRS), American Orthopedic Foot and Ankle Society (AOFAS) ankle/hindfoot score, and visual analog scale (VAS) at 3/6/9/12 months were calculated to assess the clinical outcomes. RESULTS: Thirty-six cases underwent at least a year of follow up and were enrolled in this study. The gender ratio and average age were 80.5% and 32.5 years. The linear equation fitted well (R2 = 0.95), and CUSUM for operative time peaked in the 12th case, which was divided into the learning phase (n = 12) and master phase (n = 24). No significant difference was detected between the two groups in clinical variables, except for the operative time (71.1 ± 13.2 min vs 45.8 ± 7.2 min, p = 0.004). Moreover, we detected one case with a suture reaction and treated it properly. CONCLUSION: Minimally invasive Achilles repair provides an opportunity for early rehabilitation. Notably, the learning curve showed that the "lumbar puncture needle and oval forceps" technique was accessible to surgeons.


Achilles Tendon , Learning Curve , Minimally Invasive Surgical Procedures , Tendon Injuries , Humans , Achilles Tendon/surgery , Achilles Tendon/injuries , Male , Female , Adult , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/education , Minimally Invasive Surgical Procedures/instrumentation , Middle Aged , Tendon Injuries/surgery , Rupture/surgery , Retrospective Studies , Treatment Outcome , Surgical Instruments , Needles , Operative Time
...