Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.486
Filtrar
1.
BMC Oral Health ; 24(1): 923, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123150

RESUMEN

BACKGROUND: This study aimed to explore the effects of the titanium dioxide (TiO2) concentration and particle size in hydrogen peroxide (HP) on tooth bleaching effectiveness and enamel surface properties. METHODS: TiO2 at different concentrations and particle sizes was incorporated into 40% HP gel to form an HP/TiO2 gel. The specimens were randomly divided into 8 groups: C1P20: HP + 1% TiO2 (20 nm); C3P20: HP + 3% TiO2 (20 nm); C5P20: HP + 5% TiO2 (20 nm); C1P100: HP + 1% TiO2 (100 nm); C3P100: HP + 3% TiO2 (100 nm); C5P100: HP + 5% TiO2 (100 nm); C0: HP with LED; and C0-woL: HP without LED. Bleaching was conducted over 2 sessions, each lasting 40 min with a 7-day interval. The color differences (ΔE00), whiteness index for dentistry (WID), surface microhardness, roughness, microstructure, and composition were assessed. RESULTS: The concentration and particle size of TiO2 significantly affected ΔE00 and ΔWID values, with the C1P100 group showing the greatest ΔE00 values and C1P100, C3P100, and C5P100 groups showing the greatest ΔWID values (p < 0.05). No significant changes were observed in surface microhardness, roughness, microstructure or composition (p > 0.05). CONCLUSIONS: Incorporating 1% TiO2 with a particle size of 100 nm into HP constitutes an effective bleaching strategy to achieve desirable outcomes.


Asunto(s)
Geles , Peróxido de Hidrógeno , Propiedades de Superficie , Titanio , Blanqueadores Dentales , Blanqueamiento de Dientes , Titanio/química , Blanqueamiento de Dientes/métodos , Peróxido de Hidrógeno/uso terapéutico , Peróxido de Hidrógeno/administración & dosificación , Humanos , Tamaño de la Partícula , Esmalte Dental/efectos de los fármacos
2.
Int J Esthet Dent ; 19(3): 268-280, 2024 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-39092820

RESUMEN

AIM: The objective of the present study was to investigate the association between the anatomical characteristics of different tooth groups and the diffusion and bleaching effect of hydrogen peroxide (H2O2). MATERIALS AND METHODS: Computed tomography (CT) images from five patients were used to assess the hard tissue thickness and pulp volume (PV) of four tooth groups: lower (mandibular) incisors (LI), upper (maxillary) incisors (UI), canines (C), and premolars (PM). Additionally, 80 bovine tooth disks were divided into four groups (n = 20) to match the thickness of each tooth group studied. All the specimens were exposed to a 35% H2O2 bleaching gel, with 50 µL applied for 45 min during the first, second, and third sessions. Diffusion was evaluated using the peroxidase enzyme method. Color change analyses (∆E, ∆E00, and ∆WID) were performed after the three application sessions and 7 days after the bleaching treatment using a spectrophotometer. RESULTS: The PM group showed greater thickness and PV, followed by the C, UI, and LI groups (P 0.001). The LI group had six times greater H2O2 diffusion compared with the PM group (P 0.001), while the PM group exhibited a PV nine times larger than the LI group. Furthermore, the LI and UI groups achieved color saturation with one fewer session than the C and PM groups. CONCLUSIONS: Specific tooth groups have anatomical characteristics that interfere with bleaching treatment in terms of the diffusion and whitening effect of H2O2. Furthermore, the diffusion capacity of H2O2 was inversely proportional to the thickness of the tooth groups.


Asunto(s)
Peróxido de Hidrógeno , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Animales , Incisivo/anatomía & histología , Incisivo/diagnóstico por imagen , Bovinos , Tomografía Computarizada por Rayos X/métodos , Diente Premolar/diagnóstico por imagen , Diente Premolar/anatomía & histología , Blanqueadores Dentales , Diente Canino/diagnóstico por imagen , Diente Canino/anatomía & histología , Pulpa Dental/diagnóstico por imagen , Pulpa Dental/anatomía & histología , Pulpa Dental/efectos de los fármacos , Espectrofotometría/métodos
3.
BMC Oral Health ; 24(1): 897, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107715

RESUMEN

BACKGROUND: Patients tend to favor the whitening mouthwashes as they are easily applied and affordable. This study aimed to evaluate the effect of hydrogen peroxide versus charcoal-based whitening mouthwashes on color, surface roughness, and color stability of enamel. In the current study, the whitening mouthwashes used have the ability to stop future stains due to their white seal technology. METHODS: A total of 21 permanent central incisor teeth extracted for periodontal reasons were used in the present study. Teeth roots were sectioned and crowns were mounted in self-cured acrylic resin blocks. The specimens were randomly divided into three groups (n = 7) according to the tested whitening mouthwash: Control group ? DW" (Distilled water), ?OW" group: Peroxide-based mouthwash (Colgate Optic White) and ?CP" group: Charcoal-based mouthwash (Colgate® Plax Charcoal). Regarding ?OW" and ?CP" groups, the specimens were immersed in 20 ml of the tested mouthwash in each corresponding group for 1 min twice daily (morning and evening) for a total of 12 uninterrupted weeks. Color change was assessed using VITA Easyshade spectrophotometer and surface roughness (Ra) was measured using a white light interferometer. The specimens were stained using black tea solution and color was measured after 24 h of immersion for assessment of color stability. RESULTS: Color change results revealed that both whitening mouthwashes were able to restore color comparable to the control group with no significant difference between them. Regarding surface roughness, the control group showed the highest mean Ra value, followed by ?OW" group while ?CP" group showed the lowest mean Ra value. While color stability after staining, the control group showed a significantly higher value than the ?CP" and ?OW" groups. CONCLUSION: Hydrogen peroxide and charcoal-based whitening mouthwashes improve the color of enamel with no adverse effect on the surface roughness. Both whitening mouthwashes were beneficial to maintain the color after staining and prevent future enamel stains.


Asunto(s)
Carbón Orgánico , Color , Esmalte Dental , Peróxido de Hidrógeno , Antisépticos Bucales , Propiedades de Superficie , Blanqueadores Dentales , Peróxido de Hidrógeno/química , Antisépticos Bucales/farmacología , Antisépticos Bucales/química , Humanos , Esmalte Dental/efectos de los fármacos , Blanqueadores Dentales/farmacología , Espectrofotometría , Blanqueamiento de Dientes/métodos
4.
Pediatr Dent ; 46(4): 277-284, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39123328

RESUMEN

Purpose: The purpose of this study was to assess, in vitro, the color stability and bleaching response of three bulk-fill composite resins-Activa™, Tetric®-N-Ceram Bulk-Fill, and Filtek™ One Bulk-Fill???and one conventional composite resin, Filtek™ Z250, after immersion in commonly consumed carbonated beverages and subsequent home bleaching with 15 percent carbamide peroxide. Methods: Ninety-six samples (two- and four-mm thick) of the materials were immersed in malt drink, energy drink, cola, or distilled water for one day, one week, and two months. After two months, samples underwent home bleaching with 15 percent carbamide peroxide gel. Spectrophotometric analysis measured color and whiteness changes pre-immersion, post-immersion, and post-bleaching. Statistical significance was determined using factorial mixed analysis of variance (ANOVA), three-way ANOVA, and Bonferroni post hoc tests (P<0.05). Results: All tested composite resins exhibited unacceptable discoloration (color change greater than 3.3) after two months in carbonated beverages. Filtek™ One Bulk-Fill and Filtek™ Z250 displayed the most significant discoloration, particularly when immersed in the malt drink (P<0.05). In contrast, Activa™ samples reached unacceptable discoloration within just one week in malt and cola drinks. Home bleaching yielded limited whiteness recovery, with Activa™ presenting acceptable whiteness post-bleaching after staining with cola and energy drinks. Conclusions: This study highlights the aesthetic risks of prolonged carbonated beverage consumption and the limitations of the assessed home bleaching technique using 15 percent carbamide peroxide. Enhanced dental education on the dietary effects of some beverages on restorative materials is indicated by these findings.


Asunto(s)
Peróxido de Carbamida , Bebidas Gaseosas , Color , Resinas Compuestas , Blanqueamiento de Dientes , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales , Humanos , Peróxidos/efectos adversos , Urea/análogos & derivados , Urea/efectos adversos , Ensayo de Materiales , Espectrofotometría , Bebidas Energéticas
5.
Br Dent J ; 237(4): 288, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39179844
6.
J Esthet Restor Dent ; 36(9): 1301-1310, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39126226

RESUMEN

OBJECTIVE: To compare the color change, the risk and intensity of tooth sensitivity (TS), and gingival irritation (GI) of at-home bleaching applied on the buccal surface only or the buccal and lingual surfaces. MATERIALS AND METHODS: Sixty patients with canines A2 or darker were selected and their superior arches were randomized in two groups: at-home bleaching on the buccal-only or on the buccal and lingual surfaces, with 7.5% hydrogen peroxide, for 1 h daily/2 weeks. The color change was evaluated at baseline, 7, 14 days, and 1 month after bleaching using shade guides scales (ΔSGU) and a spectrophotometer (ΔEAB, ΔE00, and ΔWID). Risk and intensity of TS and GI were recorded daily using visual analogic scale (0-10). Patient satisfaction was evaluated with the orofacial esthetics. Paired t-test, McNemar's, and Wilcoxon signed-rank test were used for data analysis (α = 5%). RESULTS: Neither the color change nor the risk/intensity of TS was statistically different between groups (p > 0.05). Patient satisfaction increased after bleaching for both groups (p < 0.05). CONCLUSION: The addition of one contact surface does not result in an increased whitening degree compared to bleaching applied solely on the buccal surface. CLINICAL SIGNIFICANCE: Understanding the influence of surfaces interacting with the bleaching agent is crucial for comprehending the bleaching mechanism and avoiding unnecessary material expenses. Notably, employing the buccal-only technique is sufficient to achieve the desired efficacy.


Asunto(s)
Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Método Simple Ciego , Femenino , Masculino , Adulto , Peróxido de Hidrógeno/administración & dosificación , Adulto Joven
7.
BMC Oral Health ; 24(1): 942, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143460

RESUMEN

AIM: This study compared the effectiveness of several techniques in restoring compromised bonding to recently bleached enamel. METHODS: Seventy-five healthy bovine incisors were divided into five groups (n = 15). Fifteen teeth (Group 1) remained intact, whereas 60 (Groups 2 to 5) underwent at-home bleaching with 16% carbamide peroxide. The bonding procedures were as follows: Group 1: Bonding of resin composite to unbleached enamel; Group 2: Bonding immediately after bleaching; Group 3: Application of a 10% sodium ascorbate solution for 10 min before bonding; Group 4: Enamel removal to the depth of 0.5 mm; and Group 5: Increased curing time of the bonding agent to 80 instead of 20 s. After 24 h, the specimens were subjected to micro-shear testing, and the failure mode was determined. RESULTS: ANOVA revealed a significant difference in bond strength among the groups (P < 0.001). The mean bond strength was significantly lower in group 2 than in other groups (P < 0.05), which showed comparable bond strength to each other (P > 0.05). Adhesive failure was the most predominant failure type in all groups. The mixed failure occurred with a frequency of 26.7% in groups 3 and 5. The Fisher's exact test revealed a significant difference in failure modes among the groups (P = 0.047). CONCLUSIONS: The three experimental procedures used in this study, including the application of 10% sodium ascorbate before bonding, enamel removal to the depth of 0.5 mm, and increasing the curing time of the bonding agent to 80 s, were effective in restoring the compromised bonding to recently bleached enamel.


Asunto(s)
Ácido Ascórbico , Peróxido de Carbamida , Resinas Compuestas , Recubrimiento Dental Adhesivo , Esmalte Dental , Peróxidos , Resistencia al Corte , Blanqueadores Dentales , Blanqueamiento de Dientes , Urea , Animales , Bovinos , Esmalte Dental/efectos de los fármacos , Blanqueamiento de Dientes/métodos , Recubrimiento Dental Adhesivo/métodos , Peróxidos/farmacología , Resinas Compuestas/química , Ácido Ascórbico/farmacología , Urea/análogos & derivados , Urea/farmacología , Análisis del Estrés Dental , Factores de Tiempo , Ensayo de Materiales , Estrés Mecánico , Cementos de Resina/química
8.
Lasers Med Sci ; 39(1): 217, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39145805

RESUMEN

This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate® Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate® Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate® Luminous White Instant + violet LED bleaching; C: Brushing with Colgate® Total 12; LB: Brushing with Colgate® Luminous White Brilliant; LI: Brushing with Colgate® Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations. No statistically significant distinctions emerged in total color variations (∆E00 and ∆E) among the groups under scrutiny. Notably, the groups that employed Colgate® Luminous White Instant displayed elevated roughness values, irrespective of their association with violet LED, as corroborated by scanning electron microscopy examinations. It can be concluded that whitening toothpastes associated to violet LED do not influence the color change of dental enamel in fifteen days of treatment. Toothpastes with a higher number of abrasive particles showed greater changes in enamel roughness, regardless of the use of violet LED.


Asunto(s)
Color , Esmalte Dental , Propiedades de Superficie , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Esmalte Dental/efectos de los fármacos , Esmalte Dental/efectos de la radiación , Bovinos , Animales , Pastas de Dientes/química , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/efectos adversos , Propiedades de Superficie/efectos de los fármacos , Blanqueadores Dentales/efectos adversos , Técnicas In Vitro , Microscopía Electrónica de Rastreo
9.
J Dent ; 149: 105276, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39103078

RESUMEN

OBJECTIVES: The aim of this systematic review and meta-analysis was to evaluate the masking success of bleaching and/or resin infiltration treatment of fluorotic lesions in anterior teeth of adults and adolescents. DATA SOURCES: PubMed, Cochrane Library, and Embase were systematically searched from the beginning of documentation to December 31, 2023. PRIMARY OUTCOME WAS THE NUMBER OF MASKED TEETH: A tooth was considered masked when the color difference (ΔE CIE76) between fluorotic areas and the surrounding sound enamel was ≤3.7 and unmasked if ΔE > 3.7. Secondary outcomes were mean ΔE values between fluorotic and sound enamel reported for a treatment group at baseline and after any intervention as well as patient satisfaction. STUDY SELECTION: Of 1575 search results 4 publications met the inclusion criteria, comprising 230 treated anterior teeth with fluorosis in 47 patients. Meta-analyses were performed comparing the result after treatment (bleaching, resin infiltration, or bleaching followed by resin infiltration) to baseline. RESULTS: Bleaching and resin infiltration were suitable intervention strategies to improve the esthetics of fluorosis affected anterior teeth, with a combination of both treatment approaches being particularly effective in reducing the color difference between fluorotic defects and the surrounding sound enamel below the acceptability thresholds of 3.7 (success rate [95 %CI]: 0.75 [0.44, 1.06]). Patient satisfaction increased after treatments, indicating a beneficial impact on their mental health. The overall bias of the included studies was 2.5 (ROBINS-I analysis tool). CONCLUSION: There is evidence that resin infiltration with preceding bleaching therapy is more effective in masking fluorotic lesions in anterior teeth than bleaching alone. The combination therapy also showed a tendency towards higher success rates compared to infiltration alone. However, this difference was statistically not significant, and more studies are needed to further assess the efficacy of specific treatments and their combinations as well as the certainty in the evidence. The methodologic heterogeneity of study designs regarding estimation of color difference before and after treatment and bleaching protocols calls for unification in future studies. CLINICAL SIGNIFICANCE: Results of this systematic review and meta-analysis revealed the combination of bleaching followed by resin infiltration as efficacious approach for masking fluorotic lesions in young adults. While resin infiltration alone improves the aesthetic appearance of fluorotic lesions, dentists should consider a combined bleaching-infiltration regimen to achieve more favorable clinical outcome for their patients.


Asunto(s)
Estética Dental , Fluorosis Dental , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/uso terapéutico , Fluorosis Dental/terapia , Satisfacción del Paciente , Adolescente , Esmalte Dental/patología , Esmalte Dental/efectos de los fármacos , Resultado del Tratamiento , Resinas Sintéticas/uso terapéutico , Adulto , Color
10.
J Dent ; 149: 105291, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39117099

RESUMEN

OBJECTIVE: This study aims to synthesize, characterize, and assess the penetration of hydrogen peroxide (HP), color change (CC), and surface morphology changes after the application of two distinct nano-hydroxyapatite (nano-HAp). METHODS: Two nano-HAp were previously synthesized by co-precipitation: one with rod-shaped particles (RS) and the other with spherical-shaped particles (SS). The surface charge of the nano-HAp particles was determined at varying pH levels and characterized by X-ray diffraction patterns and Fourier transform infrared spectroscopy. The morphology of the samples was assessed using scanning electron microscopy (SEM). The nano-HAp particles were applied before the dental bleaching procedure. Forty teeth were divided into four groups (n = 10) according to the bleaching treatment: no treatment, bleaching with 35 % HP only, RS application and bleaching with 35 % HP, and SS application and bleaching with 35 % HP. HP concentration (µg mL-1) was measured using UV-Vis, while CC was evaluated with a digital spectrophotometer (ΔEab, ΔE00 and WID). Additionally, four teeth from each group were selected for SEM analysis. Statistical analysis encompassed one-way ANOVA, Tukey's, and Dunnet's tests. RESULTS: RS and SS were successfully synthesized by coprecipitation, primarily differing in pH during synthesis. Both variations of nano-HAp morphology significantly reduced HP diffusion into the pulp chamber (p < 0.001). Regarding enamel morphology, groups analyzed post dental bleaching exhibited greater HAp deposition on the enamel surface. Notably, this deposition did not impede CC. SIGNIFICANCE: The utilization of different nano-HAp morphologies prior to dental bleaching appears to be a promising strategy for mitigating adverse effects associated with dental bleaching procedures.


Asunto(s)
Esmalte Dental , Peróxido de Hidrógeno , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Blanqueadores Dentales , Blanqueamiento de Dientes , Difracción de Rayos X , Blanqueamiento de Dientes/métodos , Esmalte Dental/efectos de los fármacos , Humanos , Blanqueadores Dentales/química , Blanqueadores Dentales/administración & dosificación , Espectroscopía Infrarroja por Transformada de Fourier , Concentración de Iones de Hidrógeno , Color , Nanopartículas/química , Hidroxiapatitas/química , Durapatita/química , Ensayo de Materiales
11.
Georgian Med News ; (349): 103-109, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38963212

RESUMEN

Aims - to compare the color changes, the surface roughness and morphology of the enamel bleached with two different bleaching solutions (chemical and laser activated), preceded or not with acid etching. Thirty teeth of bovine prepared and haphazardly assigned to 2 groups (n=15) depending on bleaching technique. Each group subdivided to 3 subgroup (n=5) consistent with acid etching by 37% phosphoric acid. Atomic force microscopy and VITA easy shade spectrophotometer were performed twice for all the specimens before and after bleaching. ANOVA, the Paired sample t-test, and the independent sample t-test used for statistical analysis. As for the color changes, the groups that were bleached by the chemical method, the difference among the three subgroups was statistically significant. This also applies to the groups bleached with the laser method. When comparing the results of the chemical bleaching subgroups with the laser bleaching ones, the difference was not significant. Roughness results showed significant differences between certain subgroups and non-significant differences among others. However, the difference was statistically significant between the chemical and laser groups, laser technique resulted in less surface roughness than the chemical one. Acid etching before bleaching produced better colour change in both the chemical and laser assisted bleaching. In chemical bleaching, surface roughness was higher when acid etching was used. This was also true for laser bleaching technique. In general, laser assisted bleaching produced less surface roughness than chemical bleaching.


Asunto(s)
Grabado Ácido Dental , Esmalte Dental , Propiedades de Superficie , Blanqueamiento de Dientes , Esmalte Dental/efectos de los fármacos , Esmalte Dental/química , Bovinos , Animales , Blanqueamiento de Dientes/métodos , Propiedades de Superficie/efectos de los fármacos , Color , Ácidos Fosfóricos/química , Ácidos Fosfóricos/farmacología , Microscopía de Fuerza Atómica , Blanqueadores Dentales/química , Blanqueadores Dentales/farmacología , Espectrofotometría , Rayos Láser
12.
J Photochem Photobiol B ; 257: 112970, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38955079

RESUMEN

The aim of this study was to evaluate the effectiveness of a laser-assisted in-office tooth bleaching treatment, employing a diode laser (445 nm) using different power and time settings. Two hundred human incisors were collected for evaluating tooth color change (ΔΕ00) and whiteness index in dentistry (ΔWID) following laser-assisted tooth bleaching treatment. The specimens were distributed into 25 groups (n = 8) according to laser output power (0.5-2 W) and duration of irradiation (10-60 s) that was applied. ΔΕ00 and ΔWID were evaluated using a spectrophotometer at three points of time (24 h, 1 week and 1 month after treatments). Three-way ANOVA revealed that power, duration of laser irradiation, and time of measurement after bleaching treatments significantly affected both ΔΕ00 and ΔWID(p < 0.05). Furthermore, laser irradiation increased ΔΕ00 and ΔWID at all applied powers compared to the control group (p < 0.05), but this increase was dependent on the duration of irradiation. Laser irradiation significantly increased ΔΕ00 when the duration of operation was 50-60 s at 0.5-1 W, while at 1.5-2 W was significantly increased when the duration was 30-60 s. ΔWID was significant higher in the laser groups compared to the control group at all powers, except for 0.5 W where it was significant higher when the duration was 50-60 s. The outcomes of the study can help in selecting the suitable power settings and duration of laser exposure to achieve the optimal whitening results while ensuring the safety of the tooth pulp.


Asunto(s)
Láseres de Semiconductores , Blanqueamiento de Dientes , Blanqueamiento de Dientes/métodos , Humanos , Láseres de Semiconductores/uso terapéutico , Incisivo/efectos de la radiación , Factores de Tiempo , Espectrofotometría , Color
13.
Int J Biol Macromol ; 276(Pt 1): 133647, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38964693

RESUMEN

Teeth discoloration poses a widespread challenge in dental health across various regions. Conventional teeth whitening methods often result in enamel deterioration and soft tissue harm due to the utilization of incompatible whitening agents and continuous intense light exposure. Here, we propose an effective phototherapy technique for teeth whitening, employing pathways of energy transition through intersystem crossing. The integration of MoS2 nanosheets into carrageenan gel (MoS2 NSs@Carr) facilitates both photothermal-hyperthermia and the generation of reactive oxygen species (ROS) through photocatalytic processes. The efficacy of ROS generation by the phototherapeutic MoS2 NSs@Carr on teeth whitening in the scenario. This approach ensures comprehensive teeth whitening by eliminating deep-seated stains on the teeth while preserving structural integrity and avoiding any tissue toxicity. This research highlights the efficacy of the phototherapeutic MoS2 NSs@Carr for dental whitening and underscores the potential of exploring nanostructures based on MoS2 NSs for managing dental healthcare issue.


Asunto(s)
Carragenina , Disulfuros , Hidrogeles , Molibdeno , Blanqueamiento de Dientes , Molibdeno/química , Disulfuros/química , Blanqueamiento de Dientes/métodos , Hidrogeles/química , Carragenina/química , Humanos , Especies Reactivas de Oxígeno/metabolismo , Animales , Atención Odontológica , Fototerapia/métodos , Nanoestructuras/química
14.
J Dent ; 148: 105239, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39019248

RESUMEN

OBJECTIVE: Evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber, bleaching efficacy (BE) and amount of gel expended during in-office bleaching using an applicator brush tip and conventional tip from different commercial brands. MATERIALS AND METHODS: 104 human premolars were randomly distributed into thirteen groups (n = 8) according to the commercial brand: DSP White Clinic 35 % Calcium (DW), Nano White 35 % (NW), Total Blanc One-Step 35 % (TS), Whiteness HP Blue 35 % (WB), Potenza Bianco Pro SS 38 % (PB), Opalescence XTra Boost 40 % (OB), no bleaching (negative control), and application method: applicator brush tip and conventional tip for all groups. Initial HP concentration (%) was determined via titration and pH was measured with digital pH meter. Concentration (µg/mL) of HP into the pulp chamber was measured using UV-Vis spectrophotometry, the BE (ΔE*ab, ΔE00 and ΔWID) was evaluated with a digital spectrophotometer, and the amount of gel expended was evaluated using a precision analytical digital balance. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test. Comparison between HP into the pulp chamber vs BE was performed with Person's correlation (α = 0.05). RESULTS: Brush tip demonstrated a low amount of HP in the pulp chamber compared to the conventional method for all bleaching gels (p < 0.0003), as well as lower amount of gel expended (p < 0.002). The brush tip did not result in a significant difference in BE compared to the conventional (p > 0.05). No correlations were found between both factors (p > 0.05). CONCLUSION: Brush tip showed lower penetration of HP in the pulp chamber and a reduced volume of spent gel when compared to the conventional tip, for all commercial brands. CLINICAL RELEVANCE: Brush tip is recommended for bleaching gels in an attachable syringe due to its ability to reduce the penetration of HP into the pulp chamber and minimize the amount of bleaching gel used.


Asunto(s)
Geles , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Hidrógeno/química , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/instrumentación , Blanqueadores Dentales/administración & dosificación , Blanqueadores Dentales/química , Blanqueadores Dentales/farmacocinética , Cavidad Pulpar , Jeringas , Diente Premolar , Concentración de Iones de Hidrógeno , Ensayo de Materiales , Color
15.
Clin Oral Investig ; 28(8): 436, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39030259

RESUMEN

OBJECTIVES: To evaluate the effect of whitening toothpastes with different hydrogen peroxide (HP) concentrations on HP permeability, color change, and physicochemical properties, compared to at-home bleaching treatment. MATERIALS AND METHODS: Forty-nine premolars were randomized into seven groups (n = 7): untreated (control); at-home bleaching with 10% carbamide peroxide gel (AH; 10% CP) with 14 and 28 applications of 180 min each (AH [14 × 180 min] and AH [28 × 180 min]); three whitening toothpastes (3% HP; 4% HP and 5% HP) and 10% CP brushed 28 times for 90 s each (TB [28 × 90 s]). HP permeability was measured using a UV-VIS spectrophotometer and color change by a digital spectrophotometer (ΔEab, ΔE00, and ΔWID). Initial concentration, pH, and viscosity were measured through titration, digital pH meter, and rheometer, respectively. Statistical analysis included one-way ANOVA, Tukey's test, and Dunnett's test (α = 0.05). RESULTS: 4% HP group showed acidic pH, the lowest viscosity and the highest HP concentration into the pulp chamber (p < 0.05). The 10% CP groups had lower HP in the pulp chamber and greater color change than other groups (p < 0.05), except the 5% HP group in ΔEab and ΔE00. For ΔWID, the 10% CP AH groups showed greater whitening than other groups (p < 0.05). CONCLUSIONS: Whitening toothpaste with up to 5% HP resulted in higher HP permeability and less color change compared to 10% CP. Higher HP commercial concentrations in toothpaste increased whitening effect; however, acidic pH toothpastes exhibited greater HP permeability. CLINICAL RELEVANCE: Whitening toothpastes with high hydrogen peroxide concentrations were less effective than at-home bleaching, resulting in less color change and greater permeability of hydrogen peroxide, potentially increasing the risk of tooth sensitivity.


Asunto(s)
Peróxido de Carbamida , Peróxido de Hidrógeno , Espectrofotometría , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Blanqueamiento de Dientes/métodos , Pastas de Dientes/química , Humanos , Blanqueadores Dentales/química , Técnicas In Vitro , Diente Premolar , Viscosidad , Concentración de Iones de Hidrógeno , Espectrofotometría Ultravioleta , Urea/análogos & derivados , Urea/farmacología
16.
Oper Dent ; 49(4): 465-474, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38987929

RESUMEN

OBJECTIVES: This in vitro study aimed to assess the impact of incorporating calcium glycerophosphate (CaGP) and sodium fluoride (NaF) in addition to 35% hydrogen peroxide concerning the enamel mechanical and morphological properties. METHODS: Specimens of bovine enamel were chosen based on their initial surface hardness (SHi) and subsequently divided into five gel groups (n=12): 1) 35% Hydrogen Peroxide (HP) Gel; 2) HP + 0.1% NaF Gel (HP/NaF); 3) HP + 0.25% CaGP Gel (HP/CaGP); 4) HP + 0.1% NaF + 0.25% CaGP Gel (HP/NaF/CaGP) and 5) HP Blue 35% Gel (HP Blue). The bleaching gels were applied thrice, for 40 min, at intervals of 7 days each. After 21 days, the final surface hardness (SHf), integrated hardness (IH), Polydispersity Index (PdI) and Zeta Potential (Zp), surface roughness (Ra, after and before), and surface/structural analysis by Scanning Electron Microscopy (SEM) were determined. The data were submitted to ANOVA (one-way and two-way) followed by the Student-Newman-Keuls test (α=0.05). RESULTS: The addition of NaF to HP reduced demineralization by 11.5% in relation to HP (p<0.05). The NaF/CaGP association reduction is 22.8 and 20% higher in comparison to HP/NaF/CaGP and HP Blue, respectively. The IH when the PH/NaF/CaGP bleaching gel was applied, was 14% higher compared to HP and HP Blue groups. CONCLUSIONS: It can be concluded that the association of NaF and CaGP with the 35% hydrogen peroxide gel (HP/NaF/CaGP) significantly changed tooth enamel demineralization in terms of surface, depth, roughness, and enamel morphology.


Asunto(s)
Esmalte Dental , Peróxido de Hidrógeno , Fluoruro de Sodio , Blanqueadores Dentales , Esmalte Dental/efectos de los fármacos , Bovinos , Animales , Fosfatos , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Dureza , Blanqueamiento de Dientes/métodos , Técnicas In Vitro
17.
Lasers Med Sci ; 39(1): 195, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060473

RESUMEN

This study evaluated the photoactivation of hydrogen peroxide gels at different concentrations using blue or violet LED in terms of whitening efficacy and tooth sensitivity. Forty patients were randomly divided into 4 groups: HP6V (violet LED and 6% hydrogen peroxide), HP6B (blue LED and 6% hydrogen peroxide), HP35V (violet LED and 35% hydrogen peroxide), and HP35B (blue LED and 35% hydrogen peroxide). The L*, a* and b* values were measured before, 1 week and 3 months after treatment, and the ΔE and ΔWID values were calculated. Tooth sensitivity was measured using a visual analogue scale (VAS) before, immediately after, and 24 h after bleaching. The ΔE, ΔWID and bleaching sensitivity values were subjected to the ANOVA test and Bonferroni post-test. HP35V and HP35B showed higher whitening efficacy than HP6VL, while HP6V did not show statistical differences compared to the other groups. Regarding bleaching-related sensitivity, the HP6V and HP6B groups presented the lowest values when compared to HP35V and HP35B. HP6V showed whitening efficacy comparable to HP35V and HP35B but with reduced tooth sensitivity. TRIAL REGISTRATION NUMBER: NCT06165458; registration date: 12/09/2023.


Asunto(s)
Sensibilidad de la Dentina , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/instrumentación , Femenino , Adulto , Blanqueadores Dentales/administración & dosificación , Masculino , Adulto Joven , Persona de Mediana Edad , Resultado del Tratamiento
18.
Clin Oral Investig ; 28(8): 440, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042288

RESUMEN

BACKGROUND: To evaluate the decomposition rate of active hydrogen peroxide (HP) and bleaching efficacy during in-office bleaching using high-concentration HP gels with different pHs. METHOD: A randomized, parallel, double-blind controlled trial was conducted with 40 volunteers randomized into four groups (pH 5.4; pH 7.0; pH 7.7, and pH 8.0). During the first session in-office bleaching, approximately 0.01 g of the gel was collected and titrated with potassium permanganate to obtain the concentration of active HP and pH values were measured using an electrode. Bleaching efficacy was assessed using a spectrophotometer [∆Eab, ∆E00, and WID], Vita Classical and Vita Bleachedguide scales [∆SGU]. The decomposition rate of HP concentration and pH values change were calculated using ANOVA one-way. The bleaching efficacy was assessed using two-way repeated measures ANOVA. Tukey's test was applied as a post-hoc test (p < 0.05). RESULTS: All gels experienced decreasing HP concentration over time. pH 5.4 gel showed greatest reduction after 50 min (p < 0.001). pH 8.0 and 7.7 gels remained stable; pH 5.4 remained acidic, while pH 7.0 turned acidic (p < 0.001). No significant difference in bleaching degree was observed among gels. They all showed a similar and clinically important color change after two clinical sessions, remained stable 1-month post-treatment (p > 0.05). CONCLUSIONS: All bleaching gels kept at least 70% of their HP content after 50 min, suggesting that there is a surplus of HP. They provided similar whitening efficacy 1-month after bleaching. PRACTICAL IMPLICATIONS: It is possible that lower HP concentrations may be equally effective in achieving desired results while reducing the potential for side effects. CLINICAL TRIAL REGISTRY NAME: RBR-35q7s3v.


Asunto(s)
Geles , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Método Doble Ciego , Blanqueadores Dentales/química , Concentración de Iones de Hidrógeno , Peróxido de Hidrógeno/química , Blanqueamiento de Dientes/métodos , Femenino , Masculino , Adulto , Espectrofotometría , Resultado del Tratamiento
19.
Clin Oral Investig ; 28(8): 452, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39060775

RESUMEN

OBJECTIVES: To answer whether the topical drug application can reduce in-office tooth bleaching sensitivity without impairing the color change. MATERIALS AND METHODS: This review was registered on PROSPERO (CRD42024524171). Two reviewers screened PubMed, Web of Science, Scopus, Embase, and clinicaltrials.gov in March 2024 independently for randomized clinical trials investigating the efficacy of topical drug application to manage in-office tooth bleaching sensitivity. The risk of bias was assessed using Cochrane's Risk of Bias tool (RoB2). Certainty of the evidence was assessed using the Grading of Recommendations: Assessment, Development, and Evaluation tool (GRADE). The meta-analyses evaluated the bleaching sensitivity and color change with RevMan 5.4 software. RESULTS: 334 articles were retrieved. The final sample was composed of four articles. Tested drugs were Otosporin, Eugenol, Ibuprofen with arginine, and Dipyrone. The meta-analysis evidenced no difference in bleaching sensitivity up to 1 h (MD, -0.39; 95% CI, -0.89, 0.11), 24 h (MD, -0.26, 95% CI, -0.71, 0.18), or 48 h (MD, 0.00, 95% CI, -0.16, 0.16). Meta-analysis for color change evidenced no difference for color change (MD, 0.03; 95% IC, -0.56, 0.61). The risk of bias was low. The certainty of the evidence was rated moderate for bleaching sensitivity and high for color change. CONCLUSIONS: Although topical drug application did not impair color change, it was ineffective in reducing in-office tooth bleaching sensitivity. CLINICAL RELEVANCE: topical drug application on dental enamel is not an effective approach in reducing bleaching sensitivity, but several modifications can be made in future studies to possibly achieve a better outcome.


Asunto(s)
Administración Tópica , Sensibilidad de la Dentina , Ensayos Clínicos Controlados Aleatorios como Asunto , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Sensibilidad de la Dentina/tratamiento farmacológico , Blanqueadores Dentales/administración & dosificación
20.
Clin Oral Investig ; 28(8): 457, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39078468

RESUMEN

OBJECTIVE: To evaluate the effectiveness of desensitizing toothpastes in reducing post-bleaching tooth sensitivity. MATERIALS AND METHODS: A systematic review of randomized clinical trials was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Electronic searches were conducted in the PubMed/MEDLINE, Scopus, Web of Science, The Cochrane Library and Embase databases, using the following terms: (dentifrices OR toothpaste) AND (sensitive OR sensitivity OR dental sensitivity) AND (dental bleaching OR tooth bleaching OR dental whitening OR tooth whitening). RESULTS: Five studies involving 387 individuals undergoing in-office or at-home teeth bleaching were reviewed. Desensitizing toothpastes reduced sensitivity effectively after home bleaching with 22% carbamide peroxide and single-session in-office bleaching with 35% hydrogen peroxide. However, they were ineffective for home bleaching with 16% carbamide peroxide and in-office bleaching across two sessions with 35% or 38% hydrogen peroxide. CONCLUSION: Desensitizing toothpastes are effective for home bleaching with high concentration carbamide peroxide and single-session in-office bleaching with highly concentrated hydrogen peroxide, but ineffective for home bleaching with low concentration carbamide peroxide and two-session in-office bleaching with concentrated hydrogen peroxide.


Asunto(s)
Peróxido de Carbamida , Desensibilizantes Dentinarios , Sensibilidad de la Dentina , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Humanos , Sensibilidad de la Dentina/prevención & control , Sensibilidad de la Dentina/tratamiento farmacológico , Blanqueamiento de Dientes/métodos , Desensibilizantes Dentinarios/uso terapéutico , Urea/análogos & derivados , Urea/farmacología , Urea/uso terapéutico , Peróxidos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA