Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.939
Filtrar
1.
Int J Esthet Dent ; 19(3): 268-280, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39092820

RESUMEN

AIM: The objective of the present study was to investigate the association between the anatomical characteristics of different tooth groups and the diffusion and bleaching effect of hydrogen peroxide (H2O2). MATERIALS AND METHODS: Computed tomography (CT) images from five patients were used to assess the hard tissue thickness and pulp volume (PV) of four tooth groups: lower (mandibular) incisors (LI), upper (maxillary) incisors (UI), canines (C), and premolars (PM). Additionally, 80 bovine tooth disks were divided into four groups (n = 20) to match the thickness of each tooth group studied. All the specimens were exposed to a 35% H2O2 bleaching gel, with 50 µL applied for 45 min during the first, second, and third sessions. Diffusion was evaluated using the peroxidase enzyme method. Color change analyses (∆E, ∆E00, and ∆WID) were performed after the three application sessions and 7 days after the bleaching treatment using a spectrophotometer. RESULTS: The PM group showed greater thickness and PV, followed by the C, UI, and LI groups (P 0.001). The LI group had six times greater H2O2 diffusion compared with the PM group (P 0.001), while the PM group exhibited a PV nine times larger than the LI group. Furthermore, the LI and UI groups achieved color saturation with one fewer session than the C and PM groups. CONCLUSIONS: Specific tooth groups have anatomical characteristics that interfere with bleaching treatment in terms of the diffusion and whitening effect of H2O2. Furthermore, the diffusion capacity of H2O2 was inversely proportional to the thickness of the tooth groups.


Asunto(s)
Peróxido de Hidrógeno , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Animales , Incisivo/anatomía & histología , Incisivo/diagnóstico por imagen , Bovinos , Tomografía Computarizada por Rayos X/métodos , Diente Premolar/diagnóstico por imagen , Diente Premolar/anatomía & histología , Blanqueadores Dentales , Diente Canino/diagnóstico por imagen , Diente Canino/anatomía & histología , Pulpa Dental/diagnóstico por imagen , Pulpa Dental/anatomía & histología , Pulpa Dental/efectos de los fármacos , Espectrofotometría/métodos
2.
Clin Oral Investig ; 28(8): 440, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042288

RESUMEN

BACKGROUND: To evaluate the decomposition rate of active hydrogen peroxide (HP) and bleaching efficacy during in-office bleaching using high-concentration HP gels with different pHs. METHOD: A randomized, parallel, double-blind controlled trial was conducted with 40 volunteers randomized into four groups (pH 5.4; pH 7.0; pH 7.7, and pH 8.0). During the first session in-office bleaching, approximately 0.01 g of the gel was collected and titrated with potassium permanganate to obtain the concentration of active HP and pH values were measured using an electrode. Bleaching efficacy was assessed using a spectrophotometer [∆Eab, ∆E00, and WID], Vita Classical and Vita Bleachedguide scales [∆SGU]. The decomposition rate of HP concentration and pH values change were calculated using ANOVA one-way. The bleaching efficacy was assessed using two-way repeated measures ANOVA. Tukey's test was applied as a post-hoc test (p < 0.05). RESULTS: All gels experienced decreasing HP concentration over time. pH 5.4 gel showed greatest reduction after 50 min (p < 0.001). pH 8.0 and 7.7 gels remained stable; pH 5.4 remained acidic, while pH 7.0 turned acidic (p < 0.001). No significant difference in bleaching degree was observed among gels. They all showed a similar and clinically important color change after two clinical sessions, remained stable 1-month post-treatment (p > 0.05). CONCLUSIONS: All bleaching gels kept at least 70% of their HP content after 50 min, suggesting that there is a surplus of HP. They provided similar whitening efficacy 1-month after bleaching. PRACTICAL IMPLICATIONS: It is possible that lower HP concentrations may be equally effective in achieving desired results while reducing the potential for side effects. CLINICAL TRIAL REGISTRY NAME: RBR-35q7s3v.


Asunto(s)
Geles , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Método Doble Ciego , Blanqueadores Dentales/química , Concentración de Iones de Hidrógeno , Peróxido de Hidrógeno/química , Blanqueamiento de Dientes/métodos , Femenino , Masculino , Adulto , Espectrofotometría , Resultado del Tratamiento
3.
J Photochem Photobiol B ; 257: 112970, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38955079

RESUMEN

The aim of this study was to evaluate the effectiveness of a laser-assisted in-office tooth bleaching treatment, employing a diode laser (445 nm) using different power and time settings. Two hundred human incisors were collected for evaluating tooth color change (ΔΕ00) and whiteness index in dentistry (ΔWID) following laser-assisted tooth bleaching treatment. The specimens were distributed into 25 groups (n = 8) according to laser output power (0.5-2 W) and duration of irradiation (10-60 s) that was applied. ΔΕ00 and ΔWID were evaluated using a spectrophotometer at three points of time (24 h, 1 week and 1 month after treatments). Three-way ANOVA revealed that power, duration of laser irradiation, and time of measurement after bleaching treatments significantly affected both ΔΕ00 and ΔWID(p < 0.05). Furthermore, laser irradiation increased ΔΕ00 and ΔWID at all applied powers compared to the control group (p < 0.05), but this increase was dependent on the duration of irradiation. Laser irradiation significantly increased ΔΕ00 when the duration of operation was 50-60 s at 0.5-1 W, while at 1.5-2 W was significantly increased when the duration was 30-60 s. ΔWID was significant higher in the laser groups compared to the control group at all powers, except for 0.5 W where it was significant higher when the duration was 50-60 s. The outcomes of the study can help in selecting the suitable power settings and duration of laser exposure to achieve the optimal whitening results while ensuring the safety of the tooth pulp.


Asunto(s)
Láseres de Semiconductores , Blanqueamiento de Dientes , Blanqueamiento de Dientes/métodos , Humanos , Láseres de Semiconductores/uso terapéutico , Incisivo/efectos de la radiación , Factores de Tiempo , Espectrofotometría , Color
4.
Clin Oral Investig ; 28(8): 436, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39030259

RESUMEN

OBJECTIVES: To evaluate the effect of whitening toothpastes with different hydrogen peroxide (HP) concentrations on HP permeability, color change, and physicochemical properties, compared to at-home bleaching treatment. MATERIALS AND METHODS: Forty-nine premolars were randomized into seven groups (n = 7): untreated (control); at-home bleaching with 10% carbamide peroxide gel (AH; 10% CP) with 14 and 28 applications of 180 min each (AH [14 × 180 min] and AH [28 × 180 min]); three whitening toothpastes (3% HP; 4% HP and 5% HP) and 10% CP brushed 28 times for 90 s each (TB [28 × 90 s]). HP permeability was measured using a UV-VIS spectrophotometer and color change by a digital spectrophotometer (ΔEab, ΔE00, and ΔWID). Initial concentration, pH, and viscosity were measured through titration, digital pH meter, and rheometer, respectively. Statistical analysis included one-way ANOVA, Tukey's test, and Dunnett's test (α = 0.05). RESULTS: 4% HP group showed acidic pH, the lowest viscosity and the highest HP concentration into the pulp chamber (p < 0.05). The 10% CP groups had lower HP in the pulp chamber and greater color change than other groups (p < 0.05), except the 5% HP group in ΔEab and ΔE00. For ΔWID, the 10% CP AH groups showed greater whitening than other groups (p < 0.05). CONCLUSIONS: Whitening toothpaste with up to 5% HP resulted in higher HP permeability and less color change compared to 10% CP. Higher HP commercial concentrations in toothpaste increased whitening effect; however, acidic pH toothpastes exhibited greater HP permeability. CLINICAL RELEVANCE: Whitening toothpastes with high hydrogen peroxide concentrations were less effective than at-home bleaching, resulting in less color change and greater permeability of hydrogen peroxide, potentially increasing the risk of tooth sensitivity.


Asunto(s)
Peróxido de Carbamida , Peróxido de Hidrógeno , Espectrofotometría , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Blanqueamiento de Dientes/métodos , Pastas de Dientes/química , Humanos , Blanqueadores Dentales/química , Técnicas In Vitro , Diente Premolar , Viscosidad , Concentración de Iones de Hidrógeno , Espectrofotometría Ultravioleta , Urea/análogos & derivados , Urea/farmacología
5.
Lasers Med Sci ; 39(1): 195, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060473

RESUMEN

This study evaluated the photoactivation of hydrogen peroxide gels at different concentrations using blue or violet LED in terms of whitening efficacy and tooth sensitivity. Forty patients were randomly divided into 4 groups: HP6V (violet LED and 6% hydrogen peroxide), HP6B (blue LED and 6% hydrogen peroxide), HP35V (violet LED and 35% hydrogen peroxide), and HP35B (blue LED and 35% hydrogen peroxide). The L*, a* and b* values were measured before, 1 week and 3 months after treatment, and the ΔE and ΔWID values were calculated. Tooth sensitivity was measured using a visual analogue scale (VAS) before, immediately after, and 24 h after bleaching. The ΔE, ΔWID and bleaching sensitivity values were subjected to the ANOVA test and Bonferroni post-test. HP35V and HP35B showed higher whitening efficacy than HP6VL, while HP6V did not show statistical differences compared to the other groups. Regarding bleaching-related sensitivity, the HP6V and HP6B groups presented the lowest values when compared to HP35V and HP35B. HP6V showed whitening efficacy comparable to HP35V and HP35B but with reduced tooth sensitivity. TRIAL REGISTRATION NUMBER: NCT06165458; registration date: 12/09/2023.


Asunto(s)
Sensibilidad de la Dentina , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/instrumentación , Femenino , Adulto , Blanqueadores Dentales/administración & dosificación , Masculino , Adulto Joven , Persona de Mediana Edad , Resultado del Tratamiento
6.
Clin Oral Investig ; 28(8): 452, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39060775

RESUMEN

OBJECTIVES: To answer whether the topical drug application can reduce in-office tooth bleaching sensitivity without impairing the color change. MATERIALS AND METHODS: This review was registered on PROSPERO (CRD42024524171). Two reviewers screened PubMed, Web of Science, Scopus, Embase, and clinicaltrials.gov in March 2024 independently for randomized clinical trials investigating the efficacy of topical drug application to manage in-office tooth bleaching sensitivity. The risk of bias was assessed using Cochrane's Risk of Bias tool (RoB2). Certainty of the evidence was assessed using the Grading of Recommendations: Assessment, Development, and Evaluation tool (GRADE). The meta-analyses evaluated the bleaching sensitivity and color change with RevMan 5.4 software. RESULTS: 334 articles were retrieved. The final sample was composed of four articles. Tested drugs were Otosporin, Eugenol, Ibuprofen with arginine, and Dipyrone. The meta-analysis evidenced no difference in bleaching sensitivity up to 1 h (MD, -0.39; 95% CI, -0.89, 0.11), 24 h (MD, -0.26, 95% CI, -0.71, 0.18), or 48 h (MD, 0.00, 95% CI, -0.16, 0.16). Meta-analysis for color change evidenced no difference for color change (MD, 0.03; 95% IC, -0.56, 0.61). The risk of bias was low. The certainty of the evidence was rated moderate for bleaching sensitivity and high for color change. CONCLUSIONS: Although topical drug application did not impair color change, it was ineffective in reducing in-office tooth bleaching sensitivity. CLINICAL RELEVANCE: topical drug application on dental enamel is not an effective approach in reducing bleaching sensitivity, but several modifications can be made in future studies to possibly achieve a better outcome.


Asunto(s)
Administración Tópica , Sensibilidad de la Dentina , Ensayos Clínicos Controlados Aleatorios como Asunto , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Sensibilidad de la Dentina/tratamiento farmacológico , Blanqueadores Dentales/administración & dosificación
7.
Georgian Med News ; (349): 103-109, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38963212

RESUMEN

Aims - to compare the color changes, the surface roughness and morphology of the enamel bleached with two different bleaching solutions (chemical and laser activated), preceded or not with acid etching. Thirty teeth of bovine prepared and haphazardly assigned to 2 groups (n=15) depending on bleaching technique. Each group subdivided to 3 subgroup (n=5) consistent with acid etching by 37% phosphoric acid. Atomic force microscopy and VITA easy shade spectrophotometer were performed twice for all the specimens before and after bleaching. ANOVA, the Paired sample t-test, and the independent sample t-test used for statistical analysis. As for the color changes, the groups that were bleached by the chemical method, the difference among the three subgroups was statistically significant. This also applies to the groups bleached with the laser method. When comparing the results of the chemical bleaching subgroups with the laser bleaching ones, the difference was not significant. Roughness results showed significant differences between certain subgroups and non-significant differences among others. However, the difference was statistically significant between the chemical and laser groups, laser technique resulted in less surface roughness than the chemical one. Acid etching before bleaching produced better colour change in both the chemical and laser assisted bleaching. In chemical bleaching, surface roughness was higher when acid etching was used. This was also true for laser bleaching technique. In general, laser assisted bleaching produced less surface roughness than chemical bleaching.


Asunto(s)
Grabado Ácido Dental , Esmalte Dental , Propiedades de Superficie , Blanqueamiento de Dientes , Esmalte Dental/efectos de los fármacos , Esmalte Dental/química , Bovinos , Animales , Blanqueamiento de Dientes/métodos , Propiedades de Superficie/efectos de los fármacos , Color , Ácidos Fosfóricos/química , Ácidos Fosfóricos/farmacología , Microscopía de Fuerza Atómica , Blanqueadores Dentales/química , Blanqueadores Dentales/farmacología , Espectrofotometría , Rayos Láser
8.
Oper Dent ; 49(4): 465-474, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38987929

RESUMEN

OBJECTIVES: This in vitro study aimed to assess the impact of incorporating calcium glycerophosphate (CaGP) and sodium fluoride (NaF) in addition to 35% hydrogen peroxide concerning the enamel mechanical and morphological properties. METHODS: Specimens of bovine enamel were chosen based on their initial surface hardness (SHi) and subsequently divided into five gel groups (n=12): 1) 35% Hydrogen Peroxide (HP) Gel; 2) HP + 0.1% NaF Gel (HP/NaF); 3) HP + 0.25% CaGP Gel (HP/CaGP); 4) HP + 0.1% NaF + 0.25% CaGP Gel (HP/NaF/CaGP) and 5) HP Blue 35% Gel (HP Blue). The bleaching gels were applied thrice, for 40 min, at intervals of 7 days each. After 21 days, the final surface hardness (SHf), integrated hardness (IH), Polydispersity Index (PdI) and Zeta Potential (Zp), surface roughness (Ra, after and before), and surface/structural analysis by Scanning Electron Microscopy (SEM) were determined. The data were submitted to ANOVA (one-way and two-way) followed by the Student-Newman-Keuls test (α=0.05). RESULTS: The addition of NaF to HP reduced demineralization by 11.5% in relation to HP (p<0.05). The NaF/CaGP association reduction is 22.8 and 20% higher in comparison to HP/NaF/CaGP and HP Blue, respectively. The IH when the PH/NaF/CaGP bleaching gel was applied, was 14% higher compared to HP and HP Blue groups. CONCLUSIONS: It can be concluded that the association of NaF and CaGP with the 35% hydrogen peroxide gel (HP/NaF/CaGP) significantly changed tooth enamel demineralization in terms of surface, depth, roughness, and enamel morphology.


Asunto(s)
Esmalte Dental , Peróxido de Hidrógeno , Fluoruro de Sodio , Blanqueadores Dentales , Esmalte Dental/efectos de los fármacos , Bovinos , Animales , Fosfatos , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Dureza , Blanqueamiento de Dientes/métodos , Técnicas In Vitro
9.
Clin Oral Investig ; 28(8): 457, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39078468

RESUMEN

OBJECTIVE: To evaluate the effectiveness of desensitizing toothpastes in reducing post-bleaching tooth sensitivity. MATERIALS AND METHODS: A systematic review of randomized clinical trials was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Electronic searches were conducted in the PubMed/MEDLINE, Scopus, Web of Science, The Cochrane Library and Embase databases, using the following terms: (dentifrices OR toothpaste) AND (sensitive OR sensitivity OR dental sensitivity) AND (dental bleaching OR tooth bleaching OR dental whitening OR tooth whitening). RESULTS: Five studies involving 387 individuals undergoing in-office or at-home teeth bleaching were reviewed. Desensitizing toothpastes reduced sensitivity effectively after home bleaching with 22% carbamide peroxide and single-session in-office bleaching with 35% hydrogen peroxide. However, they were ineffective for home bleaching with 16% carbamide peroxide and in-office bleaching across two sessions with 35% or 38% hydrogen peroxide. CONCLUSION: Desensitizing toothpastes are effective for home bleaching with high concentration carbamide peroxide and single-session in-office bleaching with highly concentrated hydrogen peroxide, but ineffective for home bleaching with low concentration carbamide peroxide and two-session in-office bleaching with concentrated hydrogen peroxide.


Asunto(s)
Peróxido de Carbamida , Desensibilizantes Dentinarios , Sensibilidad de la Dentina , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Humanos , Sensibilidad de la Dentina/prevención & control , Sensibilidad de la Dentina/tratamiento farmacológico , Blanqueamiento de Dientes/métodos , Desensibilizantes Dentinarios/uso terapéutico , Urea/análogos & derivados , Urea/farmacología , Urea/uso terapéutico , Peróxidos/farmacología
10.
BMC Oral Health ; 24(1): 860, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39069637

RESUMEN

BACKGROUND: This study aimed to investigate the effect of whitening toothpastes on the color stability and surface roughness of resin composites stained with coffee and cigarette smoke. METHODS: Seventy-two disk-shaped specimens (6 × 2 mm) of suprananohybrid resin composite were randomly divided into two groups and exposed to coffee and cigarette smoke (n = 36). After staining, the samples randomly divided into four groups according to whitening toothpastes and were brushed for 4 min: Opalescence Whitening (OW); Colgate Optic White (COW); Curaprox Black is White (CPX) and, distilled water (control) (n = 9). Color was measured with spectrophotometer at the initial, after staining, and after brushing, and surface roughness was measured with profilometer at the initial and after brushing. A surface morphology analysis was examined using scanning electron microscopy and atomic force microscopy. The obtained data were statistically analyzed. (p < 0.05). RESULTS: Cigarette smoke caused a significantly higher color change than coffee in the resin composite (p < 0.05). Brushing with hydrogen peroxide and silica-containing whitening toothpaste showed significant differences in color change (p < 0.05). The lowest whitening effect was found in activated charcoal-containing toothpaste. While all toothpastes increased the degree of surface roughness of resin composites, the highest roughness was caused by whitening toothpastes containing activated charcoal. (p < 0.05). CONCLUSIONS: The color stability and surface properties of resin composites can be affected by brushing them with whitening toothpaste. The utilization of whitening toothpaste containing hydrogen peroxide can be considered a safe method for increasing the whiteness of discolored resin composites.


Asunto(s)
Café , Color , Resinas Compuestas , Propiedades de Superficie , Blanqueadores Dentales , Pastas de Dientes , Resinas Compuestas/química , Pastas de Dientes/química , Blanqueadores Dentales/química , Microscopía Electrónica de Rastreo , Espectrofotometría , Peróxido de Hidrógeno/química , Microscopía de Fuerza Atómica , Cepillado Dental , Blanqueamiento de Dientes/métodos , Ensayo de Materiales , Humanos , Dióxido de Silicio/química
11.
BMC Oral Health ; 24(1): 680, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867181

RESUMEN

BACKGROUND: To investigate the effect of a 50% ascorbic acid with 50% citric acid solution on the immediate shear bond strength (SBS) of metallic brackets after tooth bleaching. The enamel etching pattern and the required quantity of these combined acids as antioxidants following 35% hydrogen peroxide (HP) bleaching were also determined. METHODS: The stability of the solution at room temperature was assessed at various time intervals. Fifty teeth were randomly divided into five groups: non-bleached (G1), bleached then acid etched (G2), bleached followed by a 10-minute treatment with 10% sodium ascorbate and acid etched (G3), 5-minute treatment with 50% ascorbic acid (G4), and 5-minute treatment with a combination of 50% ascorbic acid and 50% citric acid (G5). Groups G2, G3, G4 and G5 were bleached by 35% HP gel for a total of 32 min. Acid etching in groups G1, G2, and G3 was performed using 37% phosphoric acid (Ormco®, Orange, CA, USA) for 15 s. In all groups, metal brackets were immediately bonded using Transbond™ XT primer and Transbond™ PLUS adhesive, with light curing for 40 s. The SBS was tested with a universal testing machine, and statistical analysis was conducted using one-way ANOVA followed by Tukey's HSD test. The level of significance was set at p < 0.05 for all statistical tests. RESULTS: Stability tests demonstrated that the combined acids remained effective for up to 21 days. Group G5 significantly increased the SBS of bleached teeth to the level of G1 (p < 0.05), while G3 did not achieve the same increase in SBS (p > 0.05). SEM analysis revealed enamel etching patterns similar to those of both control groups (G1 and G2). Kinetic studies at 6 min indicated that the antioxidation in G5 reacted 0.2 mmole lower than in G3 and G4. CONCLUSION: 5-minute application of the combined acids enhanced the SBS of bleached teeth comparable to unbleached teeth. The combined acids remain stable over two weeks, presenting a time-efficient, single-step solution for antioxidant application and enamel etching in orthodontic bracket bonding.


Asunto(s)
Ácido Ascórbico , Ácido Cítrico , Recubrimiento Dental Adhesivo , Esmalte Dental , Soportes Ortodóncicos , Resistencia al Corte , Blanqueamiento de Dientes , Ácido Ascórbico/farmacología , Ácido Cítrico/farmacología , Ácido Cítrico/química , Blanqueamiento de Dientes/métodos , Humanos , Proyectos Piloto , Esmalte Dental/efectos de los fármacos , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental , Antioxidantes/farmacología , Propiedades de Superficie , Factores de Tiempo , Peróxido de Hidrógeno/química , Blanqueadores Dentales/química , Ácidos Fosfóricos , Análisis del Estrés Dental
12.
Clin Oral Investig ; 28(5): 295, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700548

RESUMEN

OBJECTIVE: This randomized controlled trial aimed to evaluate the equivalence in the color change, adverse effects, self-perception (AS) and the impact on oral condition (IO) of participants submitted to different application protocols of in-office dental bleaching. MATERIALS AND METHODS: 165 participants were bleached with a 35% hydrogen peroxide gel (Total Blanc Office One-Step, DFL), according to the following protocols: (1) 2 applications of 20-min each (2 × 20 min); (2) 1 × 40-min and; (3) 1 × 30-min. The color change was evaluated with the Vita Easyshade spectrophotometer, Vita Classical and Vita Bleachedguide scales. The intensity and risk of tooth sensitivity (TS) and gingival irritation (GI) were recorded using a 0-10 visual analogue scale (VAS). AS and IO was assessed before and after the bleaching procedure using the Orofacial Aesthetic Scale and Oral Health Impact Profile-14, respectively. RESULTS: Equivalent color change were observed (p < 0.001), with no significant difference between groups. The group 2 × 20 min presented the highest risk of TS (76%, 95% CI 63 to 85), compared to the 1 × 30 min (p < 0.04). The intensity of TS and GI and the risk of GI was similar between groups (p > 0.31). Irrespectively of the group (p = 0.32), significant improvements were observed for all items of AS and IO after bleaching (p < 0.02). CONCLUSIONS: The 1 × 30 min protocol produced equivalent color change to the other bleaching protocols with reduced risk of TS and shorter application time. CLINICAL RELEVANCE: A more simplified application regimen of a single application of 30 min yields effective bleaching and patient satisfaction while minimizing undesirable side effects and improving patient satisfaction.


Asunto(s)
Sensibilidad de la Dentina , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Femenino , Peróxido de Hidrógeno/administración & dosificación , Masculino , Adulto , Método Simple Ciego , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Espectrofotometría , Resultado del Tratamiento , Persona de Mediana Edad , Estética Dental , Adolescente
13.
Int J Esthet Dent ; 19(2): 170-185, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726858

RESUMEN

Single tooth orange discoloration secondary to root canal calcification occurs as a consequence of dental trauma, orthodontic treatment, or for unknown rea- sons. A correct case history must be compiled and a CBCT study carried out in order to establish the diag- nosis and define the best treatment plan in each case. The aim of the present study was to offer a therapeutic protocol involving a clinical decision-making tree dia- gram based on the presence or absence of apical dis- ease and the degree of canal calcification. Dental bleaching and the use of ceramic veneers allow es- thetic restoration in such cases.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Blanqueamiento de Dientes , Decoloración de Dientes , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Calcificaciones de la Pulpa Dental/diagnóstico por imagen , Calcificaciones de la Pulpa Dental/etiología , Coronas con Frente Estético , Blanqueamiento de Dientes/métodos , Decoloración de Dientes/etiología , Decoloración de Dientes/terapia
14.
Am J Dent ; 37(2): 78-84, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704850

RESUMEN

PURPOSE: To evaluate how fluoride- or chitosan-based toothpaste used during at-home bleaching affects enamel roughness, tooth color, and staining susceptibility. METHODS: Bovine enamel blocks were submitted to a 14-day cycling regime considering a factorial design (bleaching agent x toothpaste, 2 x 3), with n=10: (1) bleaching with 16% carbamide peroxide (CP) or 6% hydrogen peroxide (HP), and (2) daily exposure of a fluoride (1,450 ppm F-NaF) toothpaste (FT), chitosan-based toothpaste (CBT), or distilled water (control). Then, 24 hours after the last day of bleaching procedure the samples were exposed to a coffee solution. Color (ΔEab, ΔE00, L*, a*, b*) and roughness (Ra, µm) analyses were performed to compare the samples initially (baseline), after bleaching, and after coffee staining. The results were evaluated by linear models for repeated measures (L*, a*, b*, and Ra), 2-way ANOVA (ΔEab, ΔE00) and Tukey's test (α= 0.05). RESULTS: After the at-home bleaching procedure (toothpaste vs. time, P< 0.0001), the toothpaste groups presented a statistically lower Ra than the control (CBT 0.05). After coffee exposure, CBT presented lower ΔEab and ΔE00 values in the HP groups (toothpaste, P< 0.0001), and lower b* and a* values in the CP groups (toothpaste vs. time, P= 0.004). CLINICAL SIGNIFICANCE: Fluoride or chitosan delivered by toothpaste can reduce surface alterations of the enamel during at-home bleaching, without affecting bleaching efficacy.


Asunto(s)
Peróxido de Carbamida , Quitosano , Esmalte Dental , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Decoloración de Dientes , Pastas de Dientes , Quitosano/farmacología , Pastas de Dientes/farmacología , Animales , Bovinos , Blanqueamiento de Dientes/métodos , Esmalte Dental/efectos de los fármacos , Blanqueadores Dentales/farmacología , Peróxido de Hidrógeno/farmacología , Peróxido de Carbamida/farmacología , Propiedades de Superficie , Fluoruros/farmacología , Color , Urea/análogos & derivados , Urea/farmacología , Café , Peróxidos/farmacología
15.
Am J Dent ; 37(2): 101-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704853

RESUMEN

PURPOSE: To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE00), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing. METHODS: Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE00 and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE00 and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05). RESULTS: The ΔE00 values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP. CLINICAL SIGNIFICANCE: Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.


Asunto(s)
Dentífricos , Propiedades de Superficie , Cepillado Dental , Circonio , Circonio/química , Dentífricos/uso terapéutico , Color , Blanqueadores Dentales/uso terapéutico , Pulido Dental/métodos , Itrio/química , Humanos , Ensayo de Materiales , Blanqueamiento de Dientes/métodos , Espectrofotometría , Microscopía Confocal
16.
J Dent ; 145: 104989, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582435

RESUMEN

OBJECTIVE: To map and summarize the current scientific evidence concerning the active ingredients, effectiveness, and adverse effects of over-the-counter (OTC) bleaching products. DATA AND SOURCE: This study was conducted according to the PRISMA-ScR guidelines for scoping reviews and registered on the Open Science Framework platform. STUDY SELECTION: Database searches were conducted in PubMed/MEDLINE, Embase, and Scopus up to January 2024. All in vitro, in situ, and clinical studies evaluating the effectiveness and adverse effects of OTC bleaching products were included. A descriptive analysis of the included studies was performed. RESULTS: A total of 88 studies were included. Most of them were in vitro studies (n = 49), followed by randomized clinical trials (n = 28). The main OTC bleaching products identified were whitening or stain-removing toothpastes (n = 42), followed by whitening strips (n = 39). Most clinical studies indicate that whitening strips are effective in improving tooth color and providing whitening benefits. In contrast, the bleaching effectiveness of toothpastes, mouth rinses and whitening trays was mainly supported by in vitro studies. The main adverse effects associated with OTC bleaching agents were tooth sensitivity and gingival irritation. CONCLUSION: A wide variety of OTC bleaching products is available for consumer self-administered use. Clinical studies have mainly confirmed the bleaching effectiveness of whitening strips, while the validation for toothpastes, mouth rinses and whitening trays has mainly relied on in vitro studies. Nevertheless, the use of OTC bleaching products may result in adverse effects, including tooth sensitivity, gingival irritation, and enamel surface changes. CLINICAL SIGNIFICANCE: Some over-the-counter bleaching products may have whitening properties supported by clinical studies, particularly those containing hydrogen or carbamide peroxide. Nonetheless, clinicians must be aware of the potential risks associated with excessive self-administration of these products, which may result in adverse effects.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Humanos , Peróxido de Carbamida/uso terapéutico , Sensibilidad de la Dentina/inducido químicamente , Peróxido de Hidrógeno/uso terapéutico , Peróxido de Hidrógeno/efectos adversos , Antisépticos Bucales/uso terapéutico , Antisépticos Bucales/efectos adversos , Medicamentos sin Prescripción/uso terapéutico , Medicamentos sin Prescripción/efectos adversos , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/uso terapéutico , Blanqueadores Dentales/efectos adversos , Decoloración de Dientes/inducido químicamente , Decoloración de Dientes/tratamiento farmacológico , Pastas de Dientes/uso terapéutico , Pastas de Dientes/efectos adversos
18.
Photodiagnosis Photodyn Ther ; 47: 104101, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38663486

RESUMEN

BACKGROUND: Using hydrogen peroxide (HP) for tooth bleaching may induce various side effects. Cold atmospheric plasma (CAP) is a promising solution. We aimed to evaluate and compare the efficacy and safety of tooth bleaching using high-concentration HP with CAP with conventional in-office bleaching. METHODS: Fifty-one discolored extracted human teeth were assigned to three groups: Group 1 (light-emitting diode with 35 % HP), Group 2 (CAP with 35 % HP), and Group 3 (only CAP). Bleaching was conducted over three sessions for a total of 20 min. The bleaching effect was evaluated based on the changes in color (ΔE00 and WID) and lightness (ΔL⁎ and ΔG). Safety was assessed by examining the dark areas on the enamel and monitoring the pulp chamber temperature. The study analyzed how different bleaching methods and durations affected ΔE00 and ΔWID using repeated-measures analysis of variance (ANOVA). The Kruskal-Wallis and Mann-Whitney tests were used for ΔL⁎ and dark areas, and one-way ANOVA for ΔG after 20 min of bleaching. RESULTS: The ΔE00 and WID demonstrated an interaction based on the bleaching method and time, with Group 1 exhibiting the highest ΔE00 and WID at all treatment times (p < 0.001). ΔL⁎ and ΔG did not differ significantly between Groups 1 and 2 (p = 0.056 and 0.062, respectively) and were lowest in Group 3 (p < 0.001). Group 1 exhibited the darkest areas and highest pulp chamber temperatures (p < 0.001). Group 1 exhibited statistically significant color changes. Group 2 demonstrated similar effects, but with enhanced safety profiles. CONCLUSIONS: Group 2, although displaying a slightly less pronounced color change compared with Group 1, achieved a color alteration readily discernible to the naked eye. This suggests that CAP with 35 % HP could be an interesting area for further investigation as an alternative to traditional in-office bleaching methods.


Asunto(s)
Peróxido de Hidrógeno , Gases em Plasma , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/efectos adversos , Gases em Plasma/farmacología , Blanqueadores Dentales/farmacología , Técnicas In Vitro , Decoloración de Dientes/tratamiento farmacológico
19.
J Esthet Restor Dent ; 36(8): 1208-1216, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38623067

RESUMEN

OBJECTIVES: This study was aimed to obtain an experimental bleaching agent by adding casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) in order to eliminate the mineral loss on the tooth surface after bleaching and to evaluate the bleaching effectiveness. MATERIALS AND METHODS: In this study, experimental bleaching agents containing 1%, 3% CPP-ACP and without CPP-ACP were obtained. Bleaching effectiveness (color change), the effect of bleaching agents on mineral content (energy dispersive x-ray spectroscopy), surface morphology (scanning electron microscope), and surface hardness of enamel (Vicker's microhardness) before and after bleaching were evaluated. The obtained data were statistically analyzed. RESULTS: When the bleaching levels of the groups were compared, no statistically significant difference was observed between the control and 1% CPP-ACP groups (p > 0.05) while the addition of 3% CPP-ACP decreased significantly the effectiveness of the bleaching agent (p < 0.05). When the effects of experimental bleaching agents on surface hardness were examined, while the enamel surface hardness decreased statistically significantly after application in the control group (p < 0.05), no statistically significant change was observed in surface hardness after the application of 1% CPP-ACP containing bleaching agent (p > 0.05). However, a statistically significant increase was observed in surface hardness after the application of 3% CPP-ACP containing bleaching agent (p < 0.05). When the Ca and P ratio of the groups were compared, no statistically significant difference was observed between the control and 1% CPP-ACP groups (p > 0.05), while they increased significantly in 3% CPP-ACP group (p < 0.05). CONCLUSIONS: The addition of 1% CPP-ACP to the bleaching agent had positive effects on the mineral content and surface hardness of the enamel, and did not negatively affect the whitening effectiveness. CLINICAL SIGNIFICANCE: Adding CPP-ACP to the bleaching agent at appropriate concentrations can eliminate possible negative effects without compromising the effectiveness of the bleaching agent.


Asunto(s)
Caseínas , Blanqueadores Dentales , Blanqueamiento de Dientes , Blanqueadores Dentales/farmacología , Blanqueamiento de Dientes/métodos , Esmalte Dental/efectos de los fármacos , Humanos , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Dureza , Espectrometría por Rayos X
20.
Odontology ; 112(3): 700-710, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38565694

RESUMEN

As a safe, effective, economical, and convenient technique, tooth whitening is one of the most popular treatments for improving tooth discoloration. This review summarizes the theoretical and recent research developments in the classification and mechanisms of tooth discoloration, as well as the principles, agents, effects, and side effects of tooth whitening techniques. The aim is to provide a basis for the clinical treatment of tooth whitening techniques and to suggest possible new ideas for further research. The accepted mechanism of whitening is the redox reaction of oxides in the whitening reagent, and the whitening effect is remarkable. However, side effects such as tooth sensitivity and irritation of gum and other oral soft tissues can still occur. It is recommended that more monitoring be carried out in the clinic to monitor these side effects, and care should be taken to protect the soft tissues in the mouth during office whitening procedures. Furthermore, there is a need to develop new additives or natural whitening products to reduce the occurrence of side effects.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Blanqueamiento de Dientes/métodos , Humanos , Decoloración de Dientes/inducido químicamente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA