Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 825
Filter
1.
J Am Heart Assoc ; 13(17): e032901, 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39190595

ABSTRACT

BACKGROUND: Cerebrovascular events remain one of the most devastating complications of transcatheter aortic valve implantation (TAVI). Data from real-world contemporary cohorts on longitudinal trends and outcomes remain limited. The aim of this study was to assess incidence, temporal trends, predictors, and outcomes of cerebrovascular events following transfemoral TAVI. METHODS AND RESULTS: The CENTER2 (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves 2) study includes patients undergoing TAVI between 2007 and 2022. The database contains pooled patient-level data from 10 clinical studies. A total of 24 305 patients underwent transfemoral TAVI (mean age 81.5±6.7 years, 56% women, median Society of Thoracic Surgeon Predicted Risk of Mortality 4.9% [3.1%-8.5%]). Of these patients, 2.2% (n=534) experienced stroke in the first 30 days after TAVI, and 40 (0.4%) had a transient ischemic attack. Stroke rates remained stable during the treatment period (2007-2010: 2.1%, 2011-2014: 2.5%, 2015-2018: 2.1%, 2019-2022: 2.1%; Ptrend=0.28). Moreover, 30-day cerebrovascular event rates were similar across Society of Thoracic Surgeon Predicted Risk of Mortality risk categories: 2.1% in low-risk, 2.6% in intermediate-risk, and 2.5% in high-risk patients (P=0.21). Mortality was higher in patients with 30-day stroke than without at 30 days (20.3% versus 4.7%; odds ratio, 5.1 [95% CI, 4.1-6.5]; P<0.001) and at 1 year (44.1% versus 15.0%; hazard ratio, 3.5 [95% CI, 3.0-4.2]; P<0.001). One-year mortality rates for stroke did not decline over time (2007-2010: 46.9%, 2011-2014: 46.0%, 2015-2018: 43.0%, 2019-2022: 39.1%; Ptrend=0.32). At 1 year, 7.0% of patients undergoing TAVI had a stroke. CONCLUSIONS: In 24 305 patients who underwent transfemoral TAVI, 30-day cerebrovascular event incidence remained ≈ 2.2% between 2007 and 2022. Thirty-day stroke rates were similar throughout Society of Thoracic Surgeon Predicted Risk of Mortality risk categories. Mortality rates after stroke remain high. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03588247.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Female , Male , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Incidence , Risk Factors , Aged , Femoral Artery , Stroke/epidemiology , Stroke/etiology , Risk Assessment/methods , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/etiology , Time Factors , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Postoperative Complications/etiology , Treatment Outcome , Aortic Valve/surgery
2.
Circ Cardiovasc Interv ; 17(8): e013782, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39034924

ABSTRACT

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.


Subject(s)
Bioprosthesis , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Mitral Valve , Prosthesis Design , Prosthesis Failure , Recovery of Function , Humans , Female , Male , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Aged , Prospective Studies , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Time Factors , Treatment Outcome , Risk Factors , Middle Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Risk Assessment , Aged, 80 and over , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , United States , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/diagnostic imaging , Hemodynamics , Stroke/etiology , Stroke/mortality
3.
Arq Bras Cardiol ; 121(7): e202400415, 2024 Jul 26.
Article in Portuguese, English | MEDLINE | ID: mdl-39082572
4.
Arq Bras Cardiol ; 121(7): e20230622, 2024 Jun.
Article in Portuguese, English | MEDLINE | ID: mdl-39082574

ABSTRACT

BACKGROUND: Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. OBJECTIVE: To assess TAVR's LC in Brazil over time. METHODS: We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. RESULTS: A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. CONCLUSION: A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.


Subject(s)
Hospital Mortality , Learning Curve , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/statistics & numerical data , Brazil/epidemiology , Female , Male , Aged, 80 and over , Aged , Time Factors , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Treatment Outcome , Risk Assessment
5.
Arq. bras. cardiol ; 121(7): e20230622, jun.2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1563934

ABSTRACT

Resumo Fundamento Dados robustos sobre a curva de aprendizagem (LC) da substituição da válvula aórtica transcateter (TAVR) são escassos nos países em desenvolvimento. Objetivo Avaliar a LC da TAVR no Brasil ao longo do tempo. Métodos Analisamos dados do registro brasileiro de TAVR de 2008 a 2023. Pacientes de cada centro foram numerados cronologicamente em número sequencial de caso (NSC). A LC foi realizada usando um spline cúbico restrito ajustado para o EuroSCORE-II e o uso de próteses de nova geração. Ainda, os desfechos hospitalares foram comparados entre grupos definidos de acordo com o nível de experiência, com base no NSC: 1º ao 40º caso (experiência inicial), 41º ao 80º caso (experiência básica), 81º ao 120º caso (experiência intermediária) e 121º caso em diante (experiência alta). Análises adicionais foram conduzidas de acordo com o número de casos tratados antes de 2014 (>40 e ≤40 procedimentos). O nível de significância adotado foi p <0,05. Resultados Foram incluídos 3194 pacientes de 25 centros. A idade média foi 80,7±8,1 anos e o EuroSCORE II médio foi 7±7,1. A análise da LC demonstrou uma queda na mortalidade hospitalar ajustada após o tratamento de 40 pacientes. Um patamar de nivelamento na curva foi observado após o caso 118. A mortalidade hospitalar entre os grupos foi 8,6%, 7,7%, 5,9%, e 3,7% para experiência inicial, básica, intermediária e alta, respectivamente (p<0,001). A experiência alta foi preditora independente de mortalidade mais baixa (OR 0,57, p=0,013 vs. experiência inicial). Centros com baixo volume de casos antes de 2014 não mostraram uma redução significativa na probabilidade de morte com o ganho de experiência, enquanto centros com alto volume de casos antes de 2014 apresentaram uma melhora contínua após o caso de número 10. Conclusão Observou-se um fenômeno de LC para a mortalidade hospitalar do TAVR no Brasil. Esse efeito foi mais pronunciado em centros que trataram seus 40 primeiros casos antes de 2014 que naqueles que o fizeram após 2014.


Abstract Background Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. Objective To assess TAVR's LC in Brazil over time. Methods We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. Results A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. Conclusion A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.

6.
Fernandes, Fabio; Simões, Marcus V; Correia, Edileide de Barros; Marcondes-Braga, Fabiana Goulart; Filho, Otavio Rizzi Coelho; Mesquita, Cláudio Tinoco; Mathias Junior, Wilson; Antunes, Murillo de Oliveira; Arteaga-Fernández, Edmundo; Rochitte, Carlos Eduardo; Ramires, Felix José Alvarez; Alves, Silvia Marinho Martins; Montera, Marcelo Westerlund; Lopes, Renato Delascio; Oliveira Junior, Mucio Tavares de; Scolari, Fernando Luis; Avila, Walkiria Samuel; Canesin, Manoel Fernandes; Bocchi, Edimar Alcides; Bacal, Fernando; Moura, Lidia Zytynski; Saad, Eduardo Benchimol; Scanavacca, Mauricio Ibrahim; Valdigem, Bruno Pereira; Cano, Manuel Nicolas; Abizaid, Alexandre Antonio Cunha; Ribeiro, Henrique Barbosa; Lemos Neto, Pedro Alves; Ribeiro, Gustavo Calado de Aguiar; Jatene, Fabio Biscegli; Dias, Ricardo Ribeiro; Beck-da-Silva, Luis; Rohde, Luis Eduardo Paim; Bittencourt, Marcelo Imbroinise; Pereira, Alexandre da Costa; Krieger, José Eduardo; Villacorta Junior, Humberto; Martins, Wolney de Andrade; Figueiredo Neto, José Albuquerque de; Cardoso, Juliano Novaes; Pastore, Carlos Alberto; Jatene, Ieda Biscegli; Tanaka, Ana Cristina Sayuri; Hotta, Viviane Tiemi; Romano, Minna Moreira Dias; Albuquerque, Denilson Campos de; Mourilhe-Rocha, Ricardo; Hajjar, Ludhmila Abrahão; Brito Junior, Fabio Sandoli de; Caramelli, Bruno; Calderaro, Daniela; Farsky, Pedro Silvio; Colafranceschi, Alexandre Siciliano; Pinto, Ibraim Masciarelli Francisco; Vieira, Marcelo Luiz Campos; Danzmann, Luiz Claudio; Barberato, Silvio Henrique; Mady, Charles; Martinelli Filho, Martino; Torbey, Ana Flavia Malheiros; Schwartzmann, Pedro Vellosa; Macedo, Ariane Vieira Scarlatelli; Ferreira, Silvia Moreira Ayub; Schmidt, Andre; Melo, Marcelo Dantas Tavares de; Lima Filho, Moysés Oliveira; Sposito, Andrei C; Brito, Flávio de Souza; Biolo, Andreia; Madrini Junior, Vagner; Rizk, Stephanie Itala; Mesquita, Evandro Tinoco.
Arq. bras. cardiol ; 121(7): e202400415, jun.2024. ilus, tab
Article in Portuguese | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1556404

Subject(s)
Diagnosis
9.
Circ Cardiovasc Interv ; 17(4): e013000, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38626080

ABSTRACT

BACKGROUND: Oncological patients with coronary artery disease face an elevated risk of hemorrhagic and ischemic events following percutaneous coronary intervention. Despite medical guidelines recommending minimal dual antiplatelet therapy (DAPT) duration for patients with cancer, dedicated data on abbreviated DAPT in this population is lacking. This study aims to evaluate the occurrence of ischemic and hemorrhagic events in patients with cancer compared with other high-bleeding risk individuals. METHODS: Patient-level data from 4 high-bleeding risk coronary drug-eluting stent studies (ONYX One, LEADERS FREE, LEADERS FREE II, and SENIOR trials) treated with short DAPT were analyzed. The comparison focused on patients with high-bleeding risk with and without cancer, assessing 1-year rates of net adverse clinical events (all-cause death, myocardial infarction, stroke, revascularization, and Bleeding Academic Research Consortium [BARC] types 3 to 5 bleeding) and major adverse clinical events (all-cause death, myocardial infarction, stroke). RESULTS: A total of 5232 patients were included, of whom 574 individuals had cancer, and 4658 were at high-bleeding risk without previous cancer. Despite being younger with fewer risk factors, patients with cancer had higher net adverse clinical event (HR, 1.25; P=0.01) and major adverse clinical event (HR, 1.26; P=0.02), primarily driven by all-cause mortality and major bleeding (BARC 3-5), but not myocardial infarction, stroke, stent thrombosis, or repeat revascularization. Cancer was an independent predictor of net adverse clinical event (P=0.005), major adverse clinical event (P=0.01), and major bleeding (P=0.03). CONCLUSIONS: The present work is the first report on abbreviated DAPT dedicated to patients with cancer. Cancer is a major marker of adverse outcomes and these events had high lethality. Despite short DAPT, patients with cancer experienced higher rates of major bleeding compared with patients without cancer with high-bleeding risk, which occurred mainly after DAPT discontinuation. These findings reinforce the need for a more detailed and individualized stratification of those patients. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03344653, NCT01623180, NCT02843633, NCT0284.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Neoplasms , Percutaneous Coronary Intervention , Stroke , Humans , Platelet Aggregation Inhibitors , Drug-Eluting Stents/adverse effects , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Myocardial Infarction/etiology , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Drug Therapy, Combination , Neoplasms/diagnosis , Neoplasms/epidemiology , Neoplasms/therapy
10.
Catheter Cardiovasc Interv ; 103(6): 873-884, 2024 May.
Article in English | MEDLINE | ID: mdl-38558510

ABSTRACT

BACKGROUND: Quantitative flow ratio (QFR) and myocardial perfusion scintigraphy (MPS) are utilized for assessing coronary artery disease (CAD) significance. We aimed to analyze their concordance and prognostic impact. AIMS: We aimed to analyze the concordance between QFR and MPS and their risk stratification. METHODS: Patients with invasive coronary angiography and MPS were categorized as concordant if QFR ≤ 0.80 and summed difference score (SDS) ≥ 4 or if QFR > 0.80 and SDS < 4; otherwise, they were discordant. Concordance was classified by coronary territory involvement: total (three territories), partial (two territories), poor (one territory), and total discordance (zero territories). Leaman score assessed coronary atherosclerotic burden. RESULTS: 2010 coronary territories (670 patients) underwent joint QFR and MPS analysis. MPS area under the curve for QFR ≤ 0.80 was 0.637. Concordance rates were total (52.5%), partial (29.1%), poor (15.8%), and total discordance (2.6%). Most concordance occurred in patients without significant CAD or with single-vessel disease (89.5%), particularly without MPS perfusion defects (91.5%). Leaman score (odds ratio [OR]: 0.839, 95% confidence interval [CI]: 0.805-0.875, p < 0.001) and MPS perfusion defect (summed stress score [SSS] ≥ 4) (OR: 0.355, 95% CI: 0.211-0.596, p < 0.001) were independent predictors for discordance. After 1400 days, no significant difference in death/myocardial infarction was observed based on MPS assessment, but Leaman score, functional Leaman score, and average QFR identified higher risk patients. CONCLUSIONS: MPS showed good overall accuracy in assessing QFR significance but substantial discordance existed. Predictors for discordance included higher atherosclerotic burden and MPS perfusion defects (SSS ≥ 4). Leaman score, QFR-based functional Leaman score, and average QFR provided better risk stratification for all-cause death and myocardial infarction than MPS.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Coronary Vessels , Myocardial Perfusion Imaging , Predictive Value of Tests , Humans , Myocardial Perfusion Imaging/methods , Female , Male , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Coronary Artery Disease/mortality , Middle Aged , Aged , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Prognosis , Retrospective Studies , Risk Assessment , Risk Factors , Reproducibility of Results , Coronary Circulation , Severity of Illness Index , Tomography, Emission-Computed, Single-Photon , Fractional Flow Reserve, Myocardial , Time Factors
11.
Rev. Soc. Cardiol. Estado São Paulo, Supl. ; 34(2B): 117-117, abr-jun. 2024. graf
Article in Portuguese | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1561534

ABSTRACT

INTRODUÇÃO: Implante transcateter de válvula aórtica (TAVI) é o tratamento de escolha para pacientes com estenose aórtica acima de 70 anos de idade com anatomia favorável. No entanto, o impacto das diferenças de entre os sexos e local de realização do procedimento (público versus privado) nos desfechos de TAVI no Brasil permanecem ainda indefinidos. MÉTODOS: O banco de dados RIBAC-NT (Registro de Implante de Bioprotese Aórtica por Cateter) incluiu 3,194 pacientes submetidos a TAVI de 2009 a 2021. Esta análise retrospectiva explorou as características basais, de procedimento e dos desfechosintra-hospitalares, estratificando os pacientes porsexo e local da realização do procedimento. Tendênciastemporaistambém foram avaliadas. RESULTADOS: Foram incluídos 1551 (49%) mulheres e 1.643 (51%) homens. As mulheres eram mais velhas(83 [78-87] vs. 81 [75-85] anos; p<0,01), porém apresentavam menor prevalência de diabetes mellitus (30,2% vs. 36,3%, p<0,01) e doença arterial coronariana (39,0% vs. 52,2%, p<0,01). Com respeito às complicações periprocedimento, as mulheres apresentaram risco 3 vezes maior de sangramento com risco de vida (6,1% vs. 2,4%, p<0,01), bem como maiores taxas de mortalidade de procedimento e intra-hospitalar (4,4% vs. 2,5% e 7,7% vs. 4,5%, respectivamente; p<0,01). A maioria dos procedimentos foi realizada em hospitais privados (66,2%), sendo que pacientes de hospitais públicos apresentaram maistaxas de complicações vasculares maiores(7,2% vs. 3,3%), implante de marcapasso (12,3% vs. 8,9%), mortalidade do procedimento (5,0% vs. 2,7%) e intra-hospitalar (7,5% vs. 5,3%; todos com p<0,01) em relação aos hospitais privados. Ao longo do tempo, as taxas de mortalidade intra-hospitalar diminuíram tanto em hospitais públicos quanto privados, principalmente no grupo de mulheres(p<0,01). CONCLUSÕES: Mulheres apresentaram maiores taxas de mortalidade de procedimento e intra- -hospitalares após TAVI em comparação aos homens, assim como taxas mais altas de sangramento com risco de vida e eventos adversos. Hospitais públicos foram associados a maiores taxas de mortalidade do que centros privados. Nos últimos anos, as mulheres experimentaram reduções mais significativas nas taxas de mortalidade, tanto em hospitais públicos quanto privados.


Subject(s)
Humans , Male , Female , Aged , Transcatheter Aortic Valve Replacement
12.
Am J Cardiol ; 214: 8-17, 2024 03 01.
Article in English | MEDLINE | ID: mdl-38104756

ABSTRACT

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Subject(s)
Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Mitral Valve/surgery , Reoperation , Heart Valve Prosthesis Implantation/adverse effects , Stroke Volume , Postoperative Complications/etiology , Risk Factors , Treatment Outcome , Ventricular Function, Left , Heart Valve Diseases/surgery , Biomarkers , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis/adverse effects
13.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Article in Portuguese, English | MEDLINE | ID: mdl-38126512

ABSTRACT

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Subject(s)
Heart Failure , Humans , Heart Failure/therapy , Sympathectomy , Heart Atria , Kidney
14.
JACC Cardiovasc Interv ; 16(24): 2951-2962, 2023 Dec 25.
Article in English | MEDLINE | ID: mdl-38151309

ABSTRACT

BACKGROUND: Bleeding is one of the most frequent complications in patients undergoing transcatheter aortic valve replacement (TAVR). Importantly, major bleeding is associated with poor clinical outcomes after TAVR. However, large studies on bleeding complications in the contemporary TAVR population are limited. OBJECTIVES: The aim of this study was to assess the incidence, temporal trends, clinical outcomes, and predictors of bleeding in patients undergoing transfemoral TAVR. METHODS: The CENTER2 study is a pooled patient-level database from 10 clinical studies including patients who underwent TAVR between 2007 and 2022. RESULTS: A total of 23,562 patients underwent transfemoral TAVR. The mean age was 81.5 ± 6.7 years, and 56% were women. Major bleeding within the first 30 days was observed in 1,545 patients (6.6%). Minor bleeding was reported in 1,143 patients (4.7%). Rates of major bleeding decreased from 11.5% in 2007-2010 to 5.5% in 2019-2022 (Ptrend < 0.001). Dual antiplatelet therapy was associated with higher major bleeding rates compared with single antiplatelet therapy (12.2% vs 9.1%; OR: 1.40; 95% CI: 1.13-1.72; P = 0.002). Patients with major bleeding had increased mortality risk during the first 30 days (14.1% vs 4.3%; OR: 3.66; 95% CI: 3.11-4.31; P < 0.001) and during 1-year follow-up (27.8% vs 14.5%; HR: 1.50; 95% CI: 1.41-1.59; P < 0.001). Minor bleeding did not affect 1-year mortality risk (16.7% vs 14.5%; HR: 1.11; 95% CI: 0.93-1.32; P = 0.27). Predictors of major bleeding were female sex and peripheral vascular disease. CONCLUSIONS: Bleeding complications remain frequent and important in patients undergoing transfemoral TAVR. Increased mortality risk in major bleeding persists after the initial 30 days. (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves [CENTER]; NCT03588247).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Incidence , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Hemorrhage/epidemiology , Hemorrhage/etiology , Risk Factors
15.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Article in English | MEDLINE | ID: mdl-37968032

ABSTRACT

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Subject(s)
Atrial Fibrillation , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Constriction, Pathologic/etiology , Treatment Outcome , Cardiac Catheterization/adverse effects , Hemodynamics , Registries , Prosthesis Design
16.
Front Cardiovasc Med ; 10: 1228305, 2023.
Article in English | MEDLINE | ID: mdl-38028447

ABSTRACT

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

18.
Front Cardiovasc Med ; 10: 1182530, 2023.
Article in English | MEDLINE | ID: mdl-37727304

ABSTRACT

B-type natriuretic peptide (BNP) and N-terminal pro-BNP (NT-pro BNP) are cardiac biomarkers that are released in response to increased ventricular and atrial wall stress. Aortic stenosis (AS) leads to hemodynamic changes and left ventricular hypertrophy and may be associated with natriuretic peptide levels. Several studies have shown that increased natriuretic peptide levels are correlated with AS severity and can predict the need for intervention. It can be useful in risk stratification, monitoring follow-up, and predicting cardiovascular outcomes of patients with severe AS. This paper aims to summarize the evidence of the role of BNP and NT-pro BNP in AS, before and after intervention.

19.
Cardiol Res ; 14(4): 291-301, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37559713

ABSTRACT

Background: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. Methods: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. Results: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16). Conclusions: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.

20.
Cardiol Res. ; 14(4): 291-301, ago.2023. ilus
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1525284

ABSTRACT

BACKGROUND: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. METHODS: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. RESULTS: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Cardiovascular Diseases , Everolimus
SELECTION OF CITATIONS
SEARCH DETAIL