1.
Acta Anaesthesiol Scand ; 67(9): 1202-1209, 2023 10.
Article in English | MEDLINE | ID: mdl-37325856

ABSTRACT

BACKGROUND: It has been reported that qualitative ultrasound assessment performed in the semi-upright position had high sensitivity to detect gastric fluid volume >1.5 mL.kg-1 . Nevertheless, the diagnostic accuracy of qualitative assessment for the diagnosis of empty stomach (fluid volume <0.8 mL.kg-1 ) has not been assessed. We aimed to assess the diagnostic accuracy of simple qualitative ultrasound assessment with and without head-of-bed elevation to 45° for the diagnosis of an empty stomach. We also aimed to determine the diagnostic accuracy of a composite ultrasound scale and clinical algorithm. METHODS: We performed a supplementary analysis of a prospective observer-blind randomized crossover trial in which adult fasting volunteers attended two distinct sessions, with the head-of-bed angled either at 0° or 45°, in a randomized order. Three tests were performed within each session, each corresponding to a different (either 0, 50, 100, 150 or 200 mL) and randomized volume of water; the same volumes were ingested in both sessions, in a randomized order. Ultrasounds were performed 3 min after water ingestion, blindly to the volume ingested. RESULTS: We included 20 volunteers in whom 120 measurements were analyzed. The sensitivity and specificity of the qualitative assessment in the semirecumbent position were 93% (95% CI: 68-100) and 89% (95% CI: 76-96), respectively. The composite scale and clinical algorithm did not have better diagnostic accuracy than the qualitative assessment performed with head-of-bed elevation. Without head-of-bed elevation, the clinical algorithm had significantly higher specificity (98% [95% CI: 88-100]) than qualitative assessment (67% [95% CI: 51-80]; p < 0.05). CONCLUSION: These results suggest that qualitative assessment in the semirecumbent position had high diagnostic accuracy for the diagnosis of fluid volume <0.8 mL.kg-1 ; this method can be used in clinical practice for reliable diagnosis of empty stomach.


Subject(s)
Fasting , Stomach , Adult , Humans , Prospective Studies , Cross-Over Studies , Stomach/diagnostic imaging , Ultrasonography/methods
2.
J Clin Anesth ; 81: 110919, 2022 10.
Article in English | MEDLINE | ID: mdl-35792453

ABSTRACT

STUDY OBJECTIVE: This study aimed to assess whether elevating the head of the bed to 45° was associated with sensitivity >90% of the qualitative ultrasound assessment for the diagnosis of gastric fluid volume > 1.5 ml.kg-1. We also assessed the performance of qualitative assessment, composite ultrasound scale, and clinical algorithm, for the diagnosis of fluid volume > 1.5 ml.kg-1 according to whether the head of the bed was elevated to 45° or not. DESIGN: Prospective randomized observer-blind crossover trial. SETTING: Hospices Civils de Lyon, France. PATIENT: Healthy adult volunteers. INTERVENTIONS: Two separate study sessions in fasting volunteers: with and without head-of-bed elevation to 45°, in a randomized order. Each session consisted of three tests, each corresponding to a randomized and different volume of water (either 0, 50, 100, 150 or 200 ml); the same volumes were used in both sessions and in a randomized order. Gastric ultrasounds were performed three minutes after the ingestion of water by an investigator blinded to the volume ingested. MEASUREMENTS: Diagnostic performance of each approach for the diagnosis of gastric fluid volume > 1.5 ml.kg-1. MAIN RESULTS: Twenty volunteers were included, and 120 measurements were analyzed. The sensitivity of the qualitative assessment for the diagnosis of gastric fluid volume > 1.5 ml.kg-1 with and without head-of-bed elevation was 91% (95%CI: 75-98) and 75% (95%CI: 57-89), respectively. The clinical algorithm with head-of-bed elevation had significantly better sensitivity than the qualitative assessment with no head-of-bed elevation; there was no significant difference for other comparisons. CONCLUSIONS: The results suggest that qualitative examination of gastric antrum in the supine position with head-of-bed elevation to 45° can discriminate between low and high gastric fluid volume with high sensitivity, while neither the composite ultrasound scale nor the clinical algorithm improved the diagnostic performance of gastric ultrasound for the diagnosis of gastric fluid volume > 1.5 ml.kg-1.


Subject(s)
Gastrointestinal Contents , Point-of-Care Systems , Adult , Cross-Over Studies , Gastrointestinal Contents/diagnostic imaging , Humans , Prospective Studies , Ultrasonography/methods , Water
3.
Anaesthesiol Intensive Ther ; 51(2): 121-125, 2019.
Article in English | MEDLINE | ID: mdl-31268273

ABSTRACT

BACKGROUND: The relationship between gastric fluid volume, volume of fluid regurgitated, and aspirated fluid volume remains unclear. Using a life-like manikin suitable for a pulmonary aspiration model, we aimed to assess the relationship between regurgitated and aspirated clear fluid volumes, and to determine the minimal value of the volume of liquid regurgitated that may lead to pulmonary aspiration of fluid volume ≥ 0.8 mL kg-1 (around 60 mL) that is likely to cause lung injury. METHODS: Several volumes of water ranging from 30 to 150 mL were injected in a randomized order, at a flow rate of 20 mL per second, into the esophagus of a manikin lying in the supine position on a non-tilted table, with the manikin head in the extension or in the sniffing position. Aspirated volumes were measured in the manikin bronchi, by an investigator blinded to the volume injected. Aspiration was defined as positive when the volume of collected water was ≥ 60 mL for at least one of the five injections of each volume of water. RESULTS: The minimal volume of water injected into the esophagus for an aspirated volume ≥ 0.8 mL kg-1 was 85 mL in the sniffing position, and was 150 mL in the extension position. CONCLUSIONS: These results suggest that the critical cut-off value of gastric fluid volume to be considered for the risk of significant pulmonary aspiration would be ≥ 85 mL (≥ 1 mL kg-1), in the sniffing position. These results should however be confirmed in further studies using other models.


Subject(s)
Gastrointestinal Contents/chemistry , Posture/physiology , Respiratory Aspiration of Gastric Contents/etiology , Water/chemistry , Adult , Humans , Manikins , Patient Positioning
4.
Acta Anaesthesiol Scand ; 63(1): 27-33, 2019 01.
Article in English | MEDLINE | ID: mdl-30084204

ABSTRACT

BACKGROUND: Emergent obstetrical procedures may require general anaesthesia in parturients at full cervical dilatation or immediately after vaginal birth. This study aimed to determine the prevalence and the predictive factors of higher estimated gastric content in parturients at full cervical dilatation with epidural analgesia and allowed to drink during the labour, and to assess the ability of the antral area measured in the semirecumbent position (SR-CSA) to identify higher estimated gastric content in this setting. METHODS: This prospective observational study was conducted between December 2016 and July 2017. Ultrasonographic examination of the antrum was performed at full cervical dilatation, within the hour preceding the beginning of expulsive efforts. Higher estimated gastric content was defined when solid content was observed and/or if the calculated gastric fluid volume was >1.5 mL/kg. RESULTS: Seventeen of 62 parturients (27%) presented higher estimated gastric content. Maximal pain intensity during the last hour of labour and time interval between the insertion of the epidural catheter and ultrasonographic examination were significantly increased in parturients with higher estimated gastric content. The threshold value of the SR-CSA to identify a higher estimated gastric content was 393 mm2 , with sensitivity = 88% and specificity = 87%. CONCLUSION: Around a quarter of parturients with epidural analgesia and free access to clear fluids during labour presented higher estimated gastric content at full cervical dilatation. The SR-CSA may be of interest for the fast ultrasound assessment of the gastric content status in case of emergent obstetrical procedures at full cervical dilatation.


Subject(s)
Analgesia, Epidural , Analgesia, Obstetrical , Gastrointestinal Contents , Labor, Obstetric , Adult , Female , Humans , Pregnancy , Prevalence , Prospective Studies , Ultrasonography
SELECTION OF CITATIONS