Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
NPJ Digit Med ; 7(1): 115, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704440

ABSTRACT

Spectral-domain optical coherence tomography (SDOCT) is the gold standard of imaging the eye in clinics. Penetration depth with such devices is, however, limited and visualization of the choroid, which is essential for diagnosing chorioretinal disease, remains limited. Whereas swept-source OCT (SSOCT) devices allow for visualization of the choroid these instruments are expensive and availability in praxis is limited. We present an artificial intelligence (AI)-based solution to enhance the visualization of the choroid in OCT scans and allow for quantitative measurements of choroidal metrics using generative deep learning (DL). Synthetically enhanced SDOCT B-scans with improved choroidal visibility were generated, leveraging matching images to learn deep anatomical features during the training. Using a single-center tertiary eye care institution cohort comprising a total of 362 SDOCT-SSOCT paired subjects, we trained our model with 150,784 images from 410 healthy, 192 glaucoma, and 133 diabetic retinopathy eyes. An independent external test dataset of 37,376 images from 146 eyes was deployed to assess the authenticity and quality of the synthetically enhanced SDOCT images. Experts' ability to differentiate real versus synthetic images was poor (47.5% accuracy). Measurements of choroidal thickness, area, volume, and vascularity index, from the reference SSOCT and synthetically enhanced SDOCT, showed high Pearson's correlations of 0.97 [95% CI: 0.96-0.98], 0.97 [0.95-0.98], 0.95 [0.92-0.98], and 0.87 [0.83-0.91], with intra-class correlation values of 0.99 [0.98-0.99], 0.98 [0.98-0.99], and 0.95 [0.96-0.98], 0.93 [0.91-0.95], respectively. Thus, our DL generative model successfully generated realistic enhanced SDOCT data that is indistinguishable from SSOCT images providing improved visualization of the choroid. This technology enabled accurate measurements of choroidal metrics previously limited by the imaging depth constraints of SDOCT. The findings open new possibilities for utilizing affordable SDOCT devices in studying the choroid in both healthy and pathological conditions.

2.
Nat Biomed Eng ; 7(8): 986-1000, 2023 08.
Article in English | MEDLINE | ID: mdl-37365268

ABSTRACT

In myopic eyes, pathological remodelling of collagen in the posterior sclera has mostly been observed ex vivo. Here we report the development of triple-input polarization-sensitive optical coherence tomography (OCT) for measuring posterior scleral birefringence. In guinea pigs and humans, the technique offers superior imaging sensitivities and accuracies than dual-input polarization-sensitive OCT. In 8-week-long studies with young guinea pigs, scleral birefringence was positively correlated with spherical equivalent refractive errors and predicted the onset of myopia. In a cross-sectional study involving adult individuals, scleral birefringence was associated with myopia status and negatively correlated with refractive errors. Triple-input polarization-sensitive OCT may help establish posterior scleral birefringence as a non-invasive biomarker for assessing the progression of myopia.


Subject(s)
Myopia , Sclera , Adult , Humans , Animals , Guinea Pigs , Sclera/diagnostic imaging , Sclera/pathology , Birefringence , Cross-Sectional Studies , Myopia/diagnostic imaging , Myopia/pathology , Biomarkers
3.
Lancet Digit Health ; 2(5): e240-e249, 2020 05.
Article in English | MEDLINE | ID: mdl-33328056

ABSTRACT

BACKGROUND: Deep learning is a novel machine learning technique that has been shown to be as effective as human graders in detecting diabetic retinopathy from fundus photographs. We used a cost-minimisation analysis to evaluate the potential savings of two deep learning approaches as compared with the current human assessment: a semi-automated deep learning model as a triage filter before secondary human assessment; and a fully automated deep learning model without human assessment. METHODS: In this economic analysis modelling study, using 39 006 consecutive patients with diabetes in a national diabetic retinopathy screening programme in Singapore in 2015, we used a decision tree model and TreeAge Pro to compare the actual cost of screening this cohort with human graders against the simulated cost for semi-automated and fully automated screening models. Model parameters included diabetic retinopathy prevalence rates, diabetic retinopathy screening costs under each screening model, cost of medical consultation, and diagnostic performance (ie, sensitivity and specificity). The primary outcome was total cost for each screening model. Deterministic sensitivity analyses were done to gauge the sensitivity of the results to key model assumptions. FINDINGS: From the health system perspective, the semi-automated screening model was the least expensive of the three models, at US$62 per patient per year. The fully automated model was $66 per patient per year, and the human assessment model was $77 per patient per year. The savings to the Singapore health system associated with switching to the semi-automated model are estimated to be $489 000, which is roughly 20% of the current annual screening cost. By 2050, Singapore is projected to have 1 million people with diabetes; at this time, the estimated annual savings would be $15 million. INTERPRETATION: This study provides a strong economic rationale for using deep learning systems as an assistive tool to screen for diabetic retinopathy. FUNDING: Ministry of Health, Singapore.


Subject(s)
Artificial Intelligence , Cost-Benefit Analysis , Diabetic Retinopathy/diagnosis , Diagnostic Techniques, Ophthalmological/economics , Image Processing, Computer-Assisted/economics , Models, Biological , Telemedicine/economics , Adult , Aged , Decision Trees , Diabetes Mellitus , Diabetic Retinopathy/economics , Health Care Costs , Humans , Machine Learning , Mass Screening/economics , Middle Aged , Ophthalmology/economics , Photography , Physical Examination , Retina/pathology , Sensitivity and Specificity , Singapore , Telemedicine/methods
4.
Eye Vis (Lond) ; 7: 21, 2020.
Article in English | MEDLINE | ID: mdl-32313813

ABSTRACT

BACKGROUND: Effective screening is a desirable method for the early detection and successful treatment for diabetic retinopathy, and fundus photography is currently the dominant medium for retinal imaging due to its convenience and accessibility. Manual screening using fundus photographs has however involved considerable costs for patients, clinicians and national health systems, which has limited its application particularly in less-developed countries. The advent of artificial intelligence, and in particular deep learning techniques, has however raised the possibility of widespread automated screening. MAIN TEXT: In this review, we first briefly survey major published advances in retinal analysis using artificial intelligence. We take care to separately describe standard multiple-field fundus photography, and the newer modalities of ultra-wide field photography and smartphone-based photography. Finally, we consider several machine learning concepts that have been particularly relevant to the domain and illustrate their usage with extant works. CONCLUSIONS: In the ophthalmology field, it was demonstrated that deep learning tools for diabetic retinopathy show clinically acceptable diagnostic performance when using colour retinal fundus images. Artificial intelligence models are among the most promising solutions to tackle the burden of diabetic retinopathy management in a comprehensive manner. However, future research is crucial to assess the potential clinical deployment, evaluate the cost-effectiveness of different DL systems in clinical practice and improve clinical acceptance.

5.
NPJ Digit Med ; 3: 40, 2020.
Article in English | MEDLINE | ID: mdl-32219181

ABSTRACT

Deep learning (DL) has been shown to be effective in developing diabetic retinopathy (DR) algorithms, possibly tackling financial and manpower challenges hindering implementation of DR screening. However, our systematic review of the literature reveals few studies studied the impact of different factors on these DL algorithms, that are important for clinical deployment in real-world settings. Using 455,491 retinal images, we evaluated two technical and three image-related factors in detection of referable DR. For technical factors, the performances of four DL models (VGGNet, ResNet, DenseNet, Ensemble) and two computational frameworks (Caffe, TensorFlow) were evaluated while for image-related factors, we evaluated image compression levels (reducing image size, 350, 300, 250, 200, 150 KB), number of fields (7-field, 2-field, 1-field) and media clarity (pseudophakic vs phakic). In detection of referable DR, four DL models showed comparable diagnostic performance (AUC 0.936-0.944). To develop the VGGNet model, two computational frameworks had similar AUC (0.936). The DL performance dropped when image size decreased below 250 KB (AUC 0.936, 0.900, p < 0.001). The DL performance performed better when there were increased number of fields (dataset 1: 2-field vs 1-field-AUC 0.936 vs 0.908, p < 0.001; dataset 2: 7-field vs 2-field vs 1-field, AUC 0.949 vs 0.911 vs 0.895). DL performed better in the pseudophakic than phakic eyes (AUC 0.918 vs 0.833, p < 0.001). Various image-related factors play more significant roles than technical factors in determining the diagnostic performance, suggesting the importance of having robust training and testing datasets for DL training and deployment in the real-world settings.

6.
Curr Diab Rep ; 19(9): 72, 2019 07 31.
Article in English | MEDLINE | ID: mdl-31367962

ABSTRACT

PURPOSE OF REVIEW: This paper systematically reviews the recent progress in diabetic retinopathy screening. It provides an integrated overview of the current state of knowledge of emerging techniques using artificial intelligence integration in national screening programs around the world. Existing methodological approaches and research insights are evaluated. An understanding of existing gaps and future directions is created. RECENT FINDINGS: Over the past decades, artificial intelligence has emerged into the scientific consciousness with breakthroughs that are sparking increasing interest among computer science and medical communities. Specifically, machine learning and deep learning (a subtype of machine learning) applications of artificial intelligence are spreading into areas that previously were thought to be only the purview of humans, and a number of applications in ophthalmology field have been explored. Multiple studies all around the world have demonstrated that such systems can behave on par with clinical experts with robust diagnostic performance in diabetic retinopathy diagnosis. However, only few tools have been evaluated in clinical prospective studies. Given the rapid and impressive progress of artificial intelligence technologies, the implementation of deep learning systems into routinely practiced diabetic retinopathy screening could represent a cost-effective alternative to help reduce the incidence of preventable blindness around the world.


Subject(s)
Diabetic Retinopathy/diagnosis , Mass Screening/methods , Artificial Intelligence , Global Health , Humans , Machine Learning , Ophthalmology/methods , Ophthalmology/trends
7.
Lancet Digit Health ; 1(1): e35-e44, 2019 05.
Article in English | MEDLINE | ID: mdl-33323239

ABSTRACT

BACKGROUND: Radical measures are required to identify and reduce blindness due to diabetes to achieve the Sustainable Development Goals by 2030. Therefore, we evaluated the accuracy of an artificial intelligence (AI) model using deep learning in a population-based diabetic retinopathy screening programme in Zambia, a lower-middle-income country. METHODS: We adopted an ensemble AI model consisting of a combination of two convolutional neural networks (an adapted VGGNet architecture and a residual neural network architecture) for classifying retinal colour fundus images. We trained our model on 76 370 retinal fundus images from 13 099 patients with diabetes who had participated in the Singapore Integrated Diabetic Retinopathy Program, between 2010 and 2013, which has been published previously. In this clinical validation study, we included all patients with a diagnosis of diabetes that attended a mobile screening unit in five urban centres in the Copperbelt province of Zambia from Feb 1 to June 31, 2012. In our model, referable diabetic retinopathy was defined as moderate non-proliferative diabetic retinopathy or worse, diabetic macular oedema, and ungradable images. Vision-threatening diabetic retinopathy comprised severe non-proliferative and proliferative diabetic retinopathy. We calculated the area under the curve (AUC), sensitivity, and specificity for referable diabetic retinopathy, and sensitivities of vision-threatening diabetic retinopathy and diabetic macular oedema compared with the grading by retinal specialists. We did a multivariate analysis for systemic risk factors and referable diabetic retinopathy between AI and human graders. FINDINGS: A total of 4504 retinal fundus images from 3093 eyes of 1574 Zambians with diabetes were prospectively recruited. Referable diabetic retinopathy was found in 697 (22·5%) eyes, vision-threatening diabetic retinopathy in 171 (5·5%) eyes, and diabetic macular oedema in 249 (8·1%) eyes. The AUC of the AI system for referable diabetic retinopathy was 0·973 (95% CI 0·969-0·978), with corresponding sensitivity of 92·25% (90·10-94·12) and specificity of 89·04% (87·85-90·28). Vision-threatening diabetic retinopathy sensitivity was 99·42% (99·15-99·68) and diabetic macular oedema sensitivity was 97·19% (96·61-97·77). The AI model and human graders showed similar outcomes in referable diabetic retinopathy prevalence detection and systemic risk factors associations. Both the AI model and human graders identified longer duration of diabetes, higher level of glycated haemoglobin, and increased systolic blood pressure as risk factors associated with referable diabetic retinopathy. INTERPRETATION: An AI system shows clinically acceptable performance in detecting referable diabetic retinopathy, vision-threatening diabetic retinopathy, and diabetic macular oedema in population-based diabetic retinopathy screening. This shows the potential application and adoption of such AI technology in an under-resourced African population to reduce the incidence of preventable blindness, even when the model is trained in a different population. FUNDING: National Medical Research Council Health Service Research Grant, Large Collaborative Grant, Ministry of Health, Singapore; the SingHealth Foundation; and the Tanoto Foundation.


Subject(s)
Artificial Intelligence , Deep Learning , Diabetic Retinopathy/diagnosis , Mass Screening , Adult , Area Under Curve , Female , Humans , Male , Neural Networks, Computer , Photography , Prospective Studies , Retina/physiopathology , Sensitivity and Specificity , Zambia
SELECTION OF CITATIONS
SEARCH DETAIL
...