Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 165
Filter
1.
Res Sq ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38978573

ABSTRACT

Background The Diabetes Telemedicine Mediterranean Diet (DiaTeleMed) Study is a fully remote randomized clinical trial evaluating personalized dietary management in individuals with type 2 diabetes (T2D). The study aims to test the efficacy of a personalized behavioral approach for dietary management of moderately-controlled T2D, versus a standardized behavioral intervention that uses one-size-fits-all dietary recommendations, versus a usual care control (UCC). The primary outcome will compare the impact of each intervention on the mean amplitude of glycemic excursions (MAGE). Methods Eligible participants are between 21 to 80 years of age diagnosed with moderately-controlled T2D (HbA1c: 6.0-8.0%), and managed on lifestyle alone or lifestyle plus metformin. Participants must be willing and able to attend virtual counseling sessions and log meals into a dietary tracking smartphone application (DayTwo), and wear a continuous glucose monitor (CGM) for up to 12 days. Participants are randomized with equal allocation (n = 255, n = 85 per arm) to one of three arms: 1) Personalized , 2) Standardized , or 3) UCC . Measurements occur at 0 (baseline), 3, and 6 months. All participants receive isocaloric energy and macronutrients targets to meet Mediterranean diet guidelines plus 14 intervention contacts over 6 months (4 weekly then 10 biweekly) to cover diabetes self-management education. The first 4 UCC intervention contacts are delivered via synchronous videoconferences followed by educational video links. Participants in Standardized receive the same education content as UCC on the same schedule. However, all intervention contacts are conducted via synchronous videoconferences, paired with Social Cognitive Theory (SCT)-based behavioral counseling, plus dietary self-monitoring of planned meals using a mobile app that provides real-time feedback on calories and macronutrients. Participants in the Personalized arm receive all elements of the Standardized intervention, plus real-time feedback on predicted post-prandial glycemic response (PPGR) to meals and snacks logged into the mobile app. Discussion The DiaTeleMed study will address an important gap in the current landscape of precision nutrition by determining the contributions of behavioral counseling and personalized nutrition recommendations on glycemic control in individuals with T2D. The fully remote methodology of the study allows for scalability and innovative delivery of personalized dietary recommendations at a population level. Trial registration: The DiaTeleMed Study is registered with ClinicalTrials.gov (Identifier: NCT05046886).

3.
Diabetes Res Clin Pract ; 209: 111589, 2024 03.
Article in English | MEDLINE | ID: mdl-38458916

ABSTRACT

Many individuals with intermediate hyperglycaemia (IH), including impaired fasting glycaemia (IFG) and impaired glucose tolerance (IGT), as presently defined, will progress to type 2 diabetes (T2D). There is confirmatory evidence that T2D can be prevented by lifestyle modification and/or medications, in people with IGT diagnosed by 2-h plasma glucose (PG) during a 75-gram oral glucose tolerance test (OGTT). Over the last 40 years, a wealth of epidemiological data has confirmed the superior value of 1-h plasma glucose (PG) over fasting PG (FPG), glycated haemoglobin (HbA1c) and 2-h PG in populations of different ethnicity, sex and age in predicting diabetes and associated complications including death. Given the relentlessly rising prevalence of diabetes, a more sensitive, practical method is needed to detect people with IH and T2D for early prevention or treatment in the often lengthy trajectory to T2D and its complications. The International Diabetes Federation (IDF) Position Statement reviews findings that the 1-h post-load PG ≥ 155 mg/dL (8.6 mmol/L) in people with normal glucose tolerance (NGT) during an OGTT is highly predictive for detecting progression to T2D, micro- and macrovascular complications, obstructive sleep apnoea, cystic fibrosis-related diabetes mellitus, metabolic dysfunction-associated steatotic liver disease, and mortality in individuals with risk factors. The 1-h PG of 209 mg/dL (11.6 mmol/L) is also diagnostic of T2D. Importantly, the 1-h PG cut points for diagnosing IH and T2D can be detected earlier than the recommended 2-h PG thresholds. Taken together, the 1-h PG provides an opportunity to avoid misclassification of glycaemic status if FPG or HbA1c alone are used. The 1-h PG also allows early detection of high-risk people for intervention to prevent progression to T2D which will benefit the sizeable and growing population of individuals at increased risk of T2D. Using a 1-h OGTT, subsequent to screening with a non-laboratory diabetes risk tool, and intervening early will favourably impact the global diabetes epidemic. Health services should consider developing a policy for screening for IH based on local human and technical resources. People with a 1-h PG ≥ 155 mg/dL (8.6 mmol/L) are considered to have IH and should be prescribed lifestyle intervention and referred to a diabetes prevention program. People with a 1-h PG ≥ 209 mg/dL (11.6 mmol/L) are considered to have T2D and should have a repeat test to confirm the diagnosis of T2D and then referred for further evaluation and treatment. The substantive data presented in the Position Statement provides strong evidence for redefining current diagnostic criteria for IH and T2D by adding the 1-h PG.


Subject(s)
Diabetes Mellitus, Type 2 , Glucose Intolerance , Hyperglycemia , Prediabetic State , Humans , Hyperglycemia/diagnosis , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Blood Glucose/metabolism , Fasting
4.
Obes Sci Pract ; 10(1): e729, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38187121

ABSTRACT

Objective: HbA1c is an insensitive marker for assessing real-time dysglycemia in obesity. This study investigated whether 1-h plasma glucose level (1-h PG) ≥155 mg/dL (8.6 mmol/L) during an oral glucose tolerance test (OGTT) and continuous glucose monitoring (CGM) measurement of glucose variability (GV) better reflected dysglycemia than HbA1c after weight loss from metabolic and bariatric surgery. Methods: This was a prospective cohort study of 10 participants with type 2 diabetes compared with 11 participants with non-diabetes undergoing sleeve gastrectomy (SG). At each research visit; before SG, and 6 weeks and 6 months post-SG, body weight, fasting lipid levels, and PG and insulin concentrations during an OGTT were analyzed. Mean amplitude of glycemic excursions (MAGE), a CGM-derived GV index, was analyzed. Results: The 1-h PG correlated with insulin resistance markers, triglyceride/HDL ratio and triglyceride glucose index in both groups before surgery. At 6 months, SG caused 22% weight loss in both groups. Despite a reduction in HbA1c by 3.0 ± 1.3% in the diabetes group (p < 0.01), 1-h PG, and MAGE remained elevated, and the oral disposition index, which represents pancreatic ß-cell function, remained reduced in the diabetes group when compared to the non-diabetes group. Conclusions: Elevation of GV markers and reduced disposition index following SG-induced weight loss in the diabetes group underscores persistent ß-cell dysfunction and the potential residual risk of diabetes complications.

5.
Adv Sci (Weinh) ; 10(35): e2303279, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37897315

ABSTRACT

Positioned within the eye, the lens supports vision by transmitting and focusing light onto the retina. As an adaptive glassy material, the lens is constituted primarily by densely-packed, polydisperse crystallin proteins that organize to resist aggregation and crystallization at high volume fractions, yet the details of how crystallins coordinate with one another to template and maintain this transparent microstructure remain unclear. The role of individual crystallin subtypes (α, ß, and γ) and paired subtype compositions, including how they experience and resist crowding-induced turbidity in solution, is explored using combinations of spectrophotometry, hard-sphere simulations, and surface pressure measurements. After assaying crystallin combinations, ß-crystallins emerged as a principal component in all mixtures that enabled dense fluid-like packing and short-range order necessary for transparency. These findings helped inform the design of lens-like hydrogel systems, which are used to monitor and manipulate the loss of transparency under different crowding conditions. When taken together, the findings illustrate the design and characterization of adaptive materials made from lens proteins that can be used to better understand mechanisms regulating transparency.


Subject(s)
Crystallins , Lens, Crystalline , Animals , Crystallins/analysis , Crystallins/chemistry , Crystallins/metabolism , Lens, Crystalline/metabolism , Vertebrates
6.
J Occup Environ Hyg ; 20(12): 610-620, 2023 12.
Article in English | MEDLINE | ID: mdl-37682702

ABSTRACT

Both respirators and surgical masks (SM) are used as source control devices. During the COVID-19 pandemic, there was much interest in understanding the extent of particle total outward leakage (TOL) from these devices. The objective of this study was to quantify the TOL for five categories of devices: SMs, National Institute for Occupational Safety and Health (NIOSH) Approved N95 filtering facepiece respirators (FFRs) without exhalation valves, NIOSH Approved N95 FFRs with exhalation valves (N95 FFRV), NIOSH Approved elastomeric half-mask respirators (EHMRs) with exhalation valves, and NIOSH Approved EHMRs with an SM covering the exhalation valve (EHMRSM). A benchtop test system was designed to test two models of each device category. Each device was mounted on a headform at three faceseal levels (0% faceseal, 50% faceseal, and 100% faceseal). At each faceseal level, the TOL was assessed at three flow rates of minute ventilations of 17, 28, and 39 L/min. The experimental design was a split-split-plot configuration. Device type, faceseal level, flow rate, and the interaction of device type and faceseal level were found to have a significant effect (p-value < 0.05) on the TOL. This study found that the N95 FFRs without exhalation valves had the lowest mean TOL. The SMs had about three times higher TOL than the N95 FFRs without exhalation valves. The TOL of the N95 FFRV was comparable to that of the SM at 0% and 50% faceseal on average overall conditions, but the N95 FFRV had a significantly higher TOL than the SM at a 100% faceseal. The EHMRs had the highest TOL because of the exhalation valve. Using an SM to cover the exhalation valve did not improve the EHMRs' efficiency in mitigating the TOL. Caution should be exercised when using N95 FFRVs as a source control measure against respiratory activities with heavy work rates, such as performing CPR. Results of this study showed that reduced faceseal leakage for N95 FFRs and SMs improves source control.


Subject(s)
Occupational Exposure , Respiratory Protective Devices , United States , Humans , Occupational Exposure/prevention & control , Masks , Pandemics , Ventilators, Mechanical , Filtration
7.
J Phys Chem B ; 127(39): 8370-8381, 2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37735840

ABSTRACT

Peptides that bind to inorganic materials can be used to functionalize surfaces, control crystallization, or assist in interfacial self-assembly. In the past, inorganic-binding peptides have been found predominantly through peptide library screening. While this method has successfully identified peptides that bind to a variety of materials, an alternative design approach that can intelligently search for peptides and provide physical insight for peptide affinity would be desirable. In this work, we develop a computational, physics-based approach to design inorganic-binding peptides, focusing on peptides that bind to the common plastics polyethylene, polypropylene, polystyrene, and poly(ethylene terephthalate). The PepBD algorithm, a Monte Carlo method that samples peptide sequence and conformational space, was modified to include simulated annealing, relax hydration constraints, and an ensemble of conformations to initiate design. These modifications led to the discovery of peptides with significantly better scores compared to those obtained using the original PepBD. PepBD scores were found to improve with increasing van der Waals interactions, although strengthening the intermolecular van der Waals interactions comes at the cost of introducing unfavorable electrostatic interactions. The best designs are enriched in amino acids with bulky side chains and possess hydrophobic and hydrophilic patches whose location depends on the adsorbed conformation. Future work will evaluate the top peptide designs in molecular dynamics simulations and experiment, enabling their application in microplastic pollution remediation and plastic-based biosensors.

9.
Diabetes Res Clin Pract ; 203: 110839, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37482221

ABSTRACT

AIMS: The timing of increase in 1-hour PG and its utility as an earlier predictor of both prediabetes (PreDM) and type 2 diabetes (T2D) compared to 2-hour PG (2 h-PG) are unknown. To evaluate the timing of crossing of the 1 h-PG ≥ 155 mg/dl (8.6 mmol/L) for PreDM and 209 mg/dl (11.6 mmol/L) for T2D and respective current 2 h-PG thresholds of 140 mg/dl (7.8 mmol/L) and 200 mg/dl (11.1 mmol/L). METHODS: Secondary analysis of 201 Southwest Native Americans who were followed longitudinally for 6-10 years and had at least 3 OGTTs. RESULTS: We identified a subset of 43 individuals who first developed PreDM by both 1 h-PG and 2 h-PG criteria during the study. For most (32/43,74%), 1 h-PG ≥ 155 mg/dl was observed before 2 h-PG reached 140 mg/dl (median [IQR]: 1.7 [-0.25, 4.59] y; mean ± SEM: 5.3 ± 1.9 y). We also identified a subset of 33 individuals who first developed T2D during the study. For most (25/33, 75%), 1 h-PG reached 209 mg/dl earlier (median 1.0 [-0.56, 2.02] y; mean ± SEM: 1.6 ± 0.8 y) than 2 h-PG reached 200 mg/dl, diagnostic of T2D. CONCLUSIONS: 1 h-PG ≥ 155 mg/dl is an earlier marker of elevated risk for PreDM and T2D than 2 h-PG ≥ 140 mg/dl.


Subject(s)
Diabetes Mellitus, Type 2 , Prediabetic State , Humans , Glucose , Blood Glucose , Diabetes Mellitus, Type 2/diagnosis , Prediabetic State/diagnosis , Glucose Tolerance Test
10.
Clin Med Insights Endocrinol Diabetes ; 16: 11795514231177206, 2023.
Article in English | MEDLINE | ID: mdl-37323220

ABSTRACT

One hour plasma glucose (1-hr PG) concentration during an oral glucose tolerance test (OGTT) is steadily emerging as an independent predictor of type 2 diabetes (T2D). Methods: We applied the current cut off thresholds reported in the pediatric literature for the 1-hr PG, 132.5 (7.4 mmol/l) and 155 mg/dL (8.6 mmol/l) during an OGTT, to report abnormal glucose tolerance (AGT) using ROC curve analyses. We determined the empirical optimal cut point for 1-hr PG for our multi ethnic cohort using the Youden Index. Results: About 1-hour and 2-hours plasma glucose showed the highest predictive potential based on Areas under the curve (AUC) values of 0.91 [CI: 0.85, 0.97] and 1 [CI: 1, 1], respectively. Further comparison of the ROC curves of the 1-hour and 2-hour PG measurements as predictors of an abnormal OGTT showed that their associated AUCs differed significantly (X2(1) = 9.25, P < .05). Using 132.5 mg/dL as the cutoff point for plasma glucose at 1-hour yielded a ROC curve with an AUC of 0.796, a sensitivity of 88%, and a specificity of 71.2%. Alternatively, the cutoff point of 155 mg/dL resulted in a ROC AUC of 0.852, a sensitivity of 80%, and a specificity of 90.4%. Conclusion: Our cross-sectional study affirms that the 1-hr PG can identify obese children and adolescents at increased risk for prediabetes and/or T2D with almost the same accuracy as a 2-hr PG. In our multi-ethnic cohort, a 1-hr PG ⩾ 155 mg/dL (8.6 mmol/l) serves as an optimal cut-point, using the estimation of the Youden index with AUC of 0.86 and sensitivity of 80%.We support the petition to consider the 1-hr PG as integral during an OGTT, as this adds value to the interpretation of the OGTT beyond the fasting and 2-hr PG.

11.
J Occup Environ Hyg ; 20(9): 365-372, 2023 09.
Article in English | MEDLINE | ID: mdl-37319423

ABSTRACT

Widespread disease outbreaks can result in prolonged wear times of National Institute for Occupational Safety and Health Approved N95 filtering facepiece respirators by healthcare personnel. Prolonged wear times of these devices can cause the development of various adverse facial skin conditions. Healthcare personnel have been reported to apply "skin protectants" to the face to reduce the pressure and friction of respirators. Because tight-fitting respirators rely on a good face seal to protect the wearer, it is important to understand if the fit is affected when skin protectants are used. This laboratory pilot study included 10 volunteers who performed quantitative fit tests to evaluate respirator fit while wearing skin protectants. Three N95 filtering facepiece respirator models and three skin protectants were evaluated. Three replicate fit tests were performed for each combination of subject, skin protectant (including a control condition of no protectant), and respirator model. Fit Factor (FF) was affected differently by the combination of the protectant type and respirator model. The main effects of the protectant type and respirator model were both significant (p < 0.001); additionally, their interaction was significant (p = 0.02), indicating FF is affected by the combined effects of the protectant type and respirator model. Compared to the control condition, using a bandage-type or surgical tape skin protectant decreased the odds of passing the fit test. Using a barrier cream skin protectant also decreased the odds of passing the fit test across all models compared to the control condition; however, the probability of passing a fit test was not statistically significantly different from the control condition (p = 0.174). These results imply that all three skin protectants reduced mean fit factors for all N95 filtering facepiece respirator models tested. The bandage-type and surgical tape skin protectants both reduced fit factors and passing rates to a greater degree than the barrier cream. Respirator users should follow respirator manufacturers' guidance on the use of skin protectants. If a skin protectant is to be worn with a tight-fitting respirator, the fit of the respirator should be evaluated with the skin protectant applied before use in the workplace.


Subject(s)
Occupational Exposure , Respiratory Protective Devices , United States , Humans , N95 Respirators , National Institute for Occupational Safety and Health, U.S. , Pilot Projects , Occupational Exposure/prevention & control , Materials Testing , Equipment Design
12.
Am J Clin Nutr ; 118(2): 443-451, 2023 08.
Article in English | MEDLINE | ID: mdl-37236549

ABSTRACT

BACKGROUND: Recent studies have demonstrated considerable interindividual variability in postprandial glucose response (PPGR) to the same foods, suggesting the need for more precise methods for predicting and controlling PPGR. In the Personal Nutrition Project, the investigators tested a precision nutrition algorithm for predicting an individual's PPGR. OBJECTIVE: This study aimed to compare changes in glycemic variability (GV) and HbA1c in 2 calorie-restricted weight loss diets in adults with prediabetes or moderately controlled type 2 diabetes (T2D), which were tertiary outcomes of the Personal Diet Study. METHODS: The Personal Diet Study was a randomized clinical trial to compare a 1-size-fits-all low-fat diet (hereafter, standardized) with a personalized diet (hereafter, personalized). Both groups received behavioral weight loss counseling and were instructed to self-monitor diets using a smartphone application. The personalized arm received personalized feedback through the application to reduce their PPGR. Continuous glucose monitoring (CGM) data were collected at baseline, 3 mo and 6 mo. Changes in mean amplitude of glycemic excursions (MAGEs) and HbA1c at 6 mo were assessed. We performed an intention-to-treat analysis using linear mixed regressions. RESULTS: We included 156 participants [66.5% women, 55.7% White, 24.1% Black, mean age 59.1 y (standard deviation (SD) = 10.7 y)] in these analyses (standardized = 75, personalized = 81). MAGE decreased by 0.83 mg/dL per month for standardized (95% CI: 0.21, 1.46 mg/dL; P = 0.009) and 0.79 mg/dL per month for personalized (95% CI: 0.19, 1.39 mg/dL; P = 0.010) diet, with no between-group differences (P = 0.92). Trends were similar for HbA1c values. CONCLUSIONS: Personalized diet did not result in an increased reduction in GV or HbA1c in patients with prediabetes and moderately controlled T2D, compared with a standardized diet. Additional subgroup analyses may help to identify patients who are more likely to benefit from this personalized intervention. This trial was registered at clinicaltrials.gov as NCT03336411.


Subject(s)
Diabetes Mellitus, Type 2 , Prediabetic State , Adult , Humans , Female , Middle Aged , Male , Glycated Hemoglobin , Blood Glucose , Diet, Fat-Restricted , Blood Glucose Self-Monitoring , Weight Loss/physiology
14.
J Occup Environ Hyg ; 20(7): 279-288, 2023 07.
Article in English | MEDLINE | ID: mdl-37084405

ABSTRACT

Loose-fitting powered air-purifying respirators (PAPRs) are used in healthcare settings, although barriers to routine, everyday usage remain, including usability concerns and potential interference with work activities. Loose-fitting PAPRs are approved by the National Institute for Occupational Safety and Health (NIOSH) and must meet minimum performance requirements, including a minimum airflow requirement of 170 L/min. One course of action to address usability concerns is to allow for the use of PAPRs designed with reduced airflow rates. The primary objective of this study was to assess the effect of PAPR flow rate and user work rate on PAPR performance, using a manikin-based assessment method. PAPR performance was quantified using the "Manikin Fit Factor" (mFF), a ratio of the challenge aerosol concentration to the in-facepiece concentration. Flow rates from 50-215 L/min and low, moderate, and high work rates were tested. Two models of NIOSH Approved loose-fitting facepiece PAPRs were tested, both having an Occupational Safety and Health Administration Assigned Protection Factor (APF) or expected level of protection, of 25. A two-way analysis of variance with an effect size model was run for each PAPR model to analyze the effects of work rate and flow rate on PAPR performance. Flow rate and work rate were found to be significant variables impacting PAPR performance. At low and moderate work rates and flow rates below the NIOSH minimum of 170 L/min, mFF was greater than or equal to 250, which is 10 times the OSHA APF of 25 for loose-fitting facepiece PAPRs. At high work rates and flow rates below 170 L/min, mFF was not greater than or equal to 250. These results suggest that some loose-fitting facepiece PAPRs designed with a flow rate lower than the current NIOSH requirement of 170 L/min may provide respirator users with expected protection at low and moderate work rates. However, when used at high work rates, some loose-fitting facepiece PAPRs designed with lower flow rates may not provide the expected level of protection.


Subject(s)
Coloboma , Occupational Exposure , Respiratory Protective Devices , Humans , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Manikins , Aerosols/analysis
16.
BMC Public Health ; 23(1): 575, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36978071

ABSTRACT

BACKGROUND: It is critical to assess implementation fidelity of evidence-based interventions and factors moderating fidelity, to understand the reasons for their success or failure. However, fidelity and fidelity moderators are seldom systematically reported. The study objective was to conduct a concurrent implementation fidelity evaluation and examine fidelity moderators of CHORD (Community Health Outreach to Reduce Diabetes), a pragmatic, cluster-randomized, controlled trial to test the impact of a Community Health Workers (CHW)-led health coaching intervention to prevent incident type 2 Diabetes Mellitus in New York (NY). METHODS: We applied the Conceptual Framework for Implementation Fidelity to assess implementation fidelity and factors moderating it across the four core intervention components: patient goal setting, education topic coaching, primary care (PC) visits, and referrals to address social determinants of health (SDH), using descriptive statistics and regression models. PC patients with prediabetes receiving care from safety-net patient-centered medical homes (PCMHs) at either, VA NY Harbor or at Bellevue Hospital (BH) were eligible to be randomized into the CHW-led CHORD intervention or usual care. Among 559 patients randomized and enrolled in the intervention group, 79.4% completed the intake survey and were included in the analytic sample for fidelity assessment. Fidelity was measured as coverage, content adherence and frequency of each core component, and the moderators assessed were implementation site and patient activation measure. RESULTS: Content adherence was high for three components with nearly 80.0% of patients setting ≥ 1 goal, having ≥ 1 PC visit and receiving ≥ 1 education session. Only 45.0% patients received ≥ 1 SDH referral. After adjusting for patient gender, language, race, ethnicity, and age, the implementation site moderated adherence to goal setting (77.4% BH vs. 87.7% VA), educational coaching (78.9% BH vs. 88.3% VA), number of successful CHW-patient encounters (6 BH vs 4 VA) and percent of patients receiving all four components (41.1% BH vs. 25.7% VA). CONCLUSIONS: The fidelity to the four CHORD intervention components differed between the two implementation sites, demonstrating the challenges in implementing complex evidence-based interventions in different settings. Our findings underscore the importance of measuring implementation fidelity in contextualizing the outcomes of randomized trials of complex multi-site behavioral interventions. TRIAL REGISTRATION: The trial was registered with ClinicalTrials.gov on 30/12/2016 and the registration number is NCT03006666 .


Subject(s)
Diabetes Mellitus, Type 2 , Humans , Diabetes Mellitus, Type 2/prevention & control , New York City , Behavior Therapy , Hospitals , Primary Health Care
18.
Diabetes Res Clin Pract ; 198: 110195, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36470316

ABSTRACT

The impact of global diabetes prevention efforts has been modest despite the promise of landmark diabetes prevention trials nearly twenty years ago. While national and regional initiatives show potential, challenges remain to adapt large-scale strategies in the real-world that fits individuals and their communities. Additionally, the sedentary lifestyle changes during the COVID-19 pandemic and guidelines that now call for earlier screening (e.g., US Preventative Task Force) will increase the pool of eligible adults worldwide. Thus, a more adaptable, person-centered approach that expands the current toolkit is urgently needed to innovate and revitalize our approach to diabetes prevention. This review identifies key priorities to optimize the population-level delivery of diabetes prevention based on a consensus-based evaluation of the current evidence among experts in global translational programs; key priorities identified include (1) participant eligibility, (2) intervention intensity, (3) delivery components, (4) behavioral economics, (5) technology, and (6) the role of pharmacotherapy. We offer a conceptual framework for a broader, person-centered approach to better address an individual's risk, readiness, barriers, and digital competency.


Subject(s)
COVID-19 , Diabetes Mellitus, Type 2 , Adult , Humans , Health Promotion , Pandemics , Diabetes Mellitus, Type 2/prevention & control , COVID-19/epidemiology , COVID-19/prevention & control , Life Style
19.
Chest ; 163(5): 1328-1339, 2023 05.
Article in English | MEDLINE | ID: mdl-36410492

ABSTRACT

BACKGROUND: Pleural biopsy findings offer greater diagnostic sensitivity in malignant pleural effusions compared with pleural fluid. The adequacy of pleural biopsy techniques in achieving molecular marker status has not been studied, and such information (termed "actionable" histology) is critical in providing a rational, efficient, and evidence-based approach to diagnostic investigation. RESEARCH QUESTION: What is the adequacy of various pleural biopsy techniques at providing adequate molecular diagnostic information to guide treatment in malignant pleural effusions? STUDY DESIGN AND METHODS: This study analyzed anonymized data on 183 patients from four sites across three countries in whom pleural biopsy results had confirmed a malignant diagnosis and molecular profiling was relevant for the diagnosed cancer type. The primary outcome measure was adequacy of pleural biopsy for achieving molecular marker status. Secondary outcomes included clinical factors predictive of achieving a molecular diagnosis. RESULTS: The median age of patients was 71 years (interquartile range, 63-78 years), with 92 of 183 (50%) male. Of the 183 procedures, 105 (57%) were local anesthetic thoracoscopies (LAT), 12 (7%) were CT scan guided, and 66 (36%) were ultrasound guided. Successful molecular marker analysis was associated with mode of biopsy, with LAT having the highest yield and ultrasound-guided biopsy the lowest (LAT vs CT scan guided vs ultrasound guided: LAT yield, 95%; CT scan guided, 86%; and ultrasound guided, 77% [P = .004]). Biopsy technique and size of biopsy sample were independently associated with successful molecular marker analysis. LAT had an adjusted OR for successful diagnosis of 30.16 (95% CI, 3.15-288.56; P = .003) and biopsy sample size an OR of 1.18 (95% CI, 1.02-1.37) per millimeter increase in tissue sample size (P < .03). INTERPRETATION: Although previous studies have shown comparable overall diagnostic yields, in the modern era of targeted therapies, this study found that LAT offers far superior results to image-guided techniques at achieving molecular profiling and remains the optimal diagnostic tool.


Subject(s)
Pleural Effusion, Malignant , Pleural Effusion , Humans , Male , Middle Aged , Aged , Female , Retrospective Studies , Pleura/pathology , Image-Guided Biopsy/methods , Ultrasonography , Pleural Effusion/pathology
20.
Acta Diabetol ; 60(1): 9-17, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36127565

ABSTRACT

AIMS: The current method to diagnose impaired glucose tolerance (IGT) is based on the 2-h plasma glucose (2-hPG) value during a 75-g oral glucose tolerance test (OGTT). Robust evidence demonstrates that the 1-h post-load plasma glucose (1-hPG) ≥ 8.6 mmol/L in those with normal glucose tolerance is highly predictive of type 2 diabetes (T2D), micro and macrovascular complications and mortality. The aim of this study was to conduct a health economic analysis to estimate long-term cost-effectiveness of using the 1-hPG compared to the 2-hPG for screening and assessing the risk of diabetes over 35 years. The main outcome was cost per quality-adjusted life year (QALY) gained. METHODS: A Monte Carlo-based Markov simulation model was developed to forecast long-term effects of two screening strategies with regards to clinical and cost-effectiveness outcomes. The base case model included 20,000 simulated patients over 35-years follow-up. Transition probabilities on disease progression, mortality, effects on preventive treatments and complications were retrieved from landmark diabetes studies. Direct medical costs were sourced from published literature and inflated to 2019 Euros. RESULTS: In the lifetime analysis, the 1-hPG was projected to increase the number of years free from disease (2 years per patient); to delay the onset of T2D (1 year per patient); to reduce the incidence of T2D complications (0·6 RR-Relative Risk per patient) and to increase the QALY gained (0·58 per patient). Even if the 1-hPG diagnostic method resulted in higher initial costs associated with preventive treatment, long-term diabetes-related costs as well as complications costs were reduced leading to a lifetime saving of - 31225719.82€. The incremental cost-effectiveness ratio was - 8214.7€ per each QALY gained for the overall population. CONCLUSIONS: Screening prediabetes with the 1-hPG is feasible and cost-effective resulting in reduced costs per QALY. Notwithstanding, the higher initial costs of testing with the 1-hPG compared to the 2-hPG due to incremental preventive intervention, long-term diabetes and complications costs were reduced projecting an overall cost saving of - 8214.7€ per each QALY gained.


Subject(s)
Diabetes Complications , Diabetes Mellitus, Type 2 , Prediabetic State , Humans , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Diabetes Mellitus, Type 2/drug therapy , Prediabetic State/diagnosis , Prediabetic State/epidemiology , Blood Glucose , Cost-Benefit Analysis , Diabetes Complications/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...