Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Orthopadie (Heidelb) ; 53(7): 479-486, 2024 Jul.
Article in German | MEDLINE | ID: mdl-38833160

ABSTRACT

This article is intended to highlight one of the key roles in endoprosthetic treatment with artificial implants and the extension of service life. Like every joint, artificial joints are subject to the physical laws of friction and wear-in short, tribology. Material pairings, surfaces and mechanisms of action in particular play a decisive role here. The special features and current findings relating to the three largest synovial joints (hip, knee and shoulder) will be discussed in detail and suggestions will be made for future developments. Continuous developments in the field of the tribology of artificial joints can massively improve care for patients. The revision figures and reasons already show the success of individual improvements in recent years.


Subject(s)
Friction , Joint Prosthesis , Humans , Prosthesis Design , Prosthesis Failure , Equipment Failure Analysis
2.
J Mech Behav Biomed Mater ; 150: 106326, 2024 02.
Article in English | MEDLINE | ID: mdl-38141361

ABSTRACT

Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure. Whether corrosive processes are a precursor of failure or rather an accompaniment of material fatigue is thereby still unclear. Therefore, this study aims to investigate the incidence of taper corrosion in a collection of 17 retrievals from a single type (MRP-Titan, Peter Brehm GmbH) and on the correlation of taper corrosion to implant and patient specific factors. None of the implants was revised for problems related to the taper junction, corrosion or the implant itself. The modular stem junction of all retrievals was visually rated with respect to corrosion, fretting and surface contamination. Additionally, the stability of taper junctions of retrievals where the proximal part with the neck was still assembled to the stem was determined by measuring the loosening moment of the securing screw and the push-out-force for taper dissociation. There was no difference between the mean push-out-force of the retrievals (14 kN ± 1.2 kN) and new reference samples (12.6 kN ± 0.5 kN). Approximately one third of the investigated retrievals showed considerable taper corrosion. The extent of corrosion increased with time in vivo and contamination of the neck piece, while it decreased with the loosening moment of the locking screw. The parameters femoral head offset, neck piece length, lateralized neck pieces, obesity of patients and septic/aseptic revision were not correlated to taper corrosion. Taper corrosion seems to occur regularly in modular taper junctions and is not necessarily connected to taper failure. A correct assembly of the junction and avoiding taper surface contamination during revision surgery is mandatory.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Hip Prosthesis/adverse effects , Corrosion , Prosthesis Design , Reoperation , Prosthesis Failure
SELECTION OF CITATIONS