Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Biology (Basel) ; 11(5)2022 Apr 23.
Article in English | MEDLINE | ID: mdl-35625375

ABSTRACT

Autologous blood doping (ABD) refers to the transfusion of one's own blood after it has been stored. Although its application is prohibited in sports, it is assumed that ABD is applied by a variety of athletes because of its benefits on exercise performance and the fact that it is not detectable so far. Therefore, this study aims at identifying changes in hematological and hemorheological parameters during the whole course of ABD procedure and to relate those changes to exercise performance. Eight healthy men conducted a 31-week ABD protocol including two blood donations and the transfusion of their own stored RBC volume corresponding to 7.7% of total blood volume. Longitudinal blood and rheological parameter measurements and analyses of RBC membrane proteins and electrolyte levels were performed. Thereby, responses of RBC sub-populations-young to old RBC-were detected. Finally, exercise tests were carried out before and after transfusion. Results indicate a higher percentage of young RBC, altered RBC deformability and electrolyte concentration due to ABD. In contrast, RBC membrane proteins remained unaffected. Running economy improved after blood transfusion. Thus, close analysis of RBC variables related to ABD detection seems feasible but should be verified in further more-detailed studies.

2.
Transfus Apher Sci ; 61(2): 103316, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34774438

ABSTRACT

BACKGROUND: The Blood Donation Service West serves North Rhine-Westphalia (NRW), Rhineland-Palatinate (RP), and Saarland, an area of 56,500 km2. In addition to routine red blood cell concentrates, plasma, and platelets, special products are provided. Since 2014, this has included autologous serum eye drops (ASED) for topical use in patients suffering from different illnesses accompanied by dry eye disease. METHODS: A volume of 250-525 mL of patient blood was collected into an anticoagulant-free blood bag. Laboratory testing included Hepatitis B/C-, HIV 1/2-, and Lues-serology. Coagulation and centrifugation were followed by leukoreduction. Single-use vials were obtained by filling mini-bag systems using a sterile tube welder. Storage at ≤-20 °C enabled a shelf-life of up to 6 months and 30 days at 4 °C after thawing for shipment. RESULTS: Contracts were closed with 15 ophthalmology clinics and medical practices in NRW and RP to supply patients with ASED. The patient pool increased from 19 in 2014 to 46 in 2020, with an average age of 43-55 years. Overall, blood collections almost tripled from 31 to 100 per year, increasing the stock of deliverable single-use vials from 3328 to 13,358. Delivery in a liquid state allowed engagement of 44 pharmacies located in the patient neighborhoods for continuous supply. CONCLUSION: Manufacturing in a closed bag system allowed integration into blood bank operations. However, cost-coverage by health insurance remained a case-by-case decision. Allogeneic application as 'just-another-blood-product' could be an aspiration. Yet, conclusive data from large clinical trials are needed for licensed provision in Germany.


Subject(s)
Blood Donors , Hematopoietic Stem Cell Transplantation , Adult , Humans , Middle Aged , Ophthalmic Solutions/therapeutic use , Red Cross , Serum
3.
Clin Hemorheol Microcirc ; 76(3): 367-379, 2020.
Article in English | MEDLINE | ID: mdl-32675400

ABSTRACT

BACKGROUND: Autologous blood doping (ABD) is applied to improve performance capacity. ABD includes blood donation, red blood cell (RBC) storage at -80°C and re-infusion prior to or during competition. ABD is not directly detectable with current detection techniques. OBJECTIVE: Since cryopreservation is known to affect RBC physiology in vitro, the aim of the study was to examine whether these alterations are detectable in vivo. METHODS: Blood from six healthy male donors was transferred into conventional blood bags, cryopreserved, stored for 18 weeks at -80°C and re-infused with a RBC volume corresponding to ∼4% of total blood volume into respective donor. RBC physiology parameters were measured before blood donation/re-infusion, and 0/1/2/6/24/48/72 h and 1 w post re-infusion. RESULTS: RBC parameters and age markers were unaffected during intervention. RBC deformability increased from pre-blood-sampling to pre-re-infusion while deformability and viscosity values remained unaltered post re-infusion. RBC nitric oxide associated analytes, metabolic parameters and electrolyte concentrations remained unaffected. CONCLUSIONS: The data of this pilot study indicate that the increase in RBC deformability might be related to neoformation of RBC after blood donation. The lack of changes in tested parameters might be related to the low re-infused RBC volume which might explain differences to in vitro results.


Subject(s)
Blood Specimen Collection/methods , Cryopreservation/methods , Doping in Sports/methods , Rheology/methods , Adult , Healthy Volunteers , Humans , Male , Pilot Projects
SELECTION OF CITATIONS
SEARCH DETAIL