Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 123: 103404, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38852365

ABSTRACT

BACKGROUND: Image-driven dose escalation to tumor subvolumes has been proposed to improve treatment outcome in head and neck cancer (HNC). We used 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) acquired at baseline and into treatment (interim) to identify biologic target volumes (BTVs). We assessed the feasibility of interim dose escalation to the BTV with proton therapy by simulating the effects to organs at risk (OARs). METHODS: We used the semiautomated just-enough-interaction (JEI) method to identify BTVs in 18F-FDG-PET images from nine HNC patients. Between baseline and interim FDG-PET, patients received photon radiotherapy. BTV was identified assuming that high standardized uptake value (SUV) at interim reflected tumor radioresistance. Using Eclipse (Varian Medical Systems), we simulated a 10% (6.8 Gy(RBE1.1)) and 20% (13.6 Gy(RBE1.1)) dose escalation to the BTV with protons and compared results with proton plans without dose escalation. RESULTS: At interim 18F-FDG-PET, radiotherapy resulted in reduced SUV compared to baseline. However, spatial overlap between high-SUV regions at baseline and interim allowed for BTV identification. Proton therapy planning demonstrated that dose escalation to the BTV was feasible, and except for some 20% dose escalation plans, OAR doses did not significantly increase. CONCLUSION: Our in silico analysis demonstrated the potential for interim 18F-FDG-PET response-adaptive dose escalation to the BTV with proton therapy. This approach may give more efficient treatment to HNC with radioresistant tumor subvolumes without increasing normal tissue toxicity. Studies in larger cohorts are required to determine the full potential for interim 18F-FDG-PET-guided dose escalation of proton therapy in HNC.


Subject(s)
Feasibility Studies , Fluorodeoxyglucose F18 , Head and Neck Neoplasms , Positron-Emission Tomography , Proton Therapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/diagnostic imaging , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Male , Female
2.
Phys Med Biol ; 69(12)2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38527373

ABSTRACT

Objective.While a constant relative biological effectiveness (RBE) of 1.1 forms the basis for clinical proton therapy, variable RBE models are increasingly being used in plan evaluation. However, there is substantial variation across RBE models, and several newin vitrodatasets have not yet been included in the existing models. In this study, an updatedin vitroproton RBE database was collected and used to examine current RBE model assumptions, and to propose an up-to-date RBE model as a tool for evaluating RBE effects in clinical settings.Approach.A proton database (471 data points) was collected from the literature, almost twice the size of the previously largest model database. Each data point included linear-quadratic model parameters and linear energy transfer (LET). Statistical analyses were performed to test the validity of commonly applied assumptions of phenomenological RBE models, and new model functions were proposed forRBEmaxandRBEmin(RBE at the lower and upper dose limits). Previously published models were refitted to the database and compared to the new model in terms of model performance and RBE estimates.Main results.The statistical analysis indicated that the intercept of theRBEmaxfunction should be a free fitting parameter and RBE estimates were clearly higher for models with free intercept.RBEminincreased with increasing LET, while a dependency ofRBEminon the reference radiation fractionation sensitivity (α/ßx) did not significantly improve model performance. Evaluating the models, the new model gave overall lowest RMSE and highest R2 score. RBE estimates in the distal part of a spread-out-Bragg-peak in water (α/ßx= 2.1 Gy) were 1.24-1.51 for original models, 1.25-1.49 for refits and 1.42 for the new model.Significance.An updated RBE model based on the currently largest database among published phenomenological models was proposed. Overall, the new model showed better performance compared to refitted published RBE models.


Subject(s)
Proton Therapy , Relative Biological Effectiveness , Proton Therapy/methods , Linear Energy Transfer , Humans , Models, Biological
SELECTION OF CITATIONS
SEARCH DETAIL