Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 79
Filter
1.
JACC Case Rep ; 29(13): 102396, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38948493

ABSTRACT

Single coronary artery, giant coronary artery aneurysm, and coronary cameral fistula are rare congenital anomalies, and can cause a range of presentations. To our knowledge, this is the first reported case of all 3 entities occurring simultaneously in 1 patient, with largely unknown implications. Multimodal imaging was essential in prompt diagnosis and management.

3.
Front Cardiovasc Med ; 11: 1286100, 2024.
Article in English | MEDLINE | ID: mdl-38385132

ABSTRACT

Background: The association between low socioeconomic status (SES) and worse surgical outcomes has become an emerging area of interest. Literature has demonstrated that carotid artery stenting (CAS) poses greater risk of postoperative complications, particularly stroke, than carotid endarterectomy (CEA). This study aims to compare the impact of low SES on patients undergoing CAS vs. CEA. Methods: The National Inpatient Sample (NIS) was queried for patients undergoing CAS and CEA from 2010 to 2015. Patients were stratified by highest and lowest median income quartiles by zip code and compared through demographics, hospital characteristics, and comorbidities defined by the Charlson Comorbidity Index (CCI). Primary outcome was in-hospital mortality. Secondary outcomes included acute kidney injury (AKI), post-operative stroke, sepsis, and bleeding requiring reoperation.Multivariable logistic regression was used to determine the effect of SES on outcomes. Results: Five thousand four hundred twenty-five patients underwent CAS (Low SES: 3,516 (64.8%); High SES: 1,909 (35.2%) and 38,399 patients underwent CEA (Low SES: 22,852 (59.5%); High SES: 15,547 (40.5%). Low SES was a significant independent predictor of mortality [OR = 2.07 (1.25-3.53); p = 0.005] for CEA patients, but not for CAS patients [OR = 1.21 (CI 0.51-2.30); p = 0.68]. Stroke was strongly associated with low SES, CEA patients (Low SES = 1.5% vs. High SES = 1.2%; p = 0.03), while bleeding was with high SES, CAS patients (Low SES = 5.3% vs. High SES = 7.1%; p = 0.01). CCI was a strong predictor of mortality for both procedures [CAS: OR1.45 (1.17-1.80); p < 0.001. CEA: OR1.60 (1.45-1.77); p < 0.001]. Advanced age was a predictor of mortality post-CEA [OR = 1.03 (1.01-1.06); p = 0.01]. While not statistically significant, advanced age and increased mortality trended towards a positive association in CAS [OR = 1.05 (1.00-1.10); p = 0.05]. Conclusions: Low SES is a significant independent predictor of post-operative mortality in patients who underwent CEA, but not CAS. CEA is also associated with higher incidence of stroke in low SES patients. Findings demonstrate the impact of SES on outcomes for patients undergoing carotid revascularization procedures. Prospective studies are warranted to further evaluate this disparity.

5.
JTCVS Open ; 15: 72-80, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808048

ABSTRACT

Objective: To investigate the effect of minimally invasive cardiac surgery (MICS) on resource utilization, cost, and postoperative outcomes in patients undergoing left-heart valve operations. Methods: Data were retrospectively reviewed for patients undergoing single-valve surgery (eg, aortic valve replacement, mitral valve replacement, or mitral valve repair) at a single center from 2018 to 2021, stratified by surgical approach: MICS vs full sternotomy (FS). Baseline characteristics and postoperative outcomes were compared. Primary outcome was high resource utilization, defined as direct procedure cost higher than the third quartile or either postoperative LOS ≥7 days or 30-day readmission. Secondary outcomes were direct cost, length of stay, 30-day readmission, in-hospital and 30-day mortality, and major morbidity. Multiple regression analysis was conducted, controlling for baseline characteristics, operative approach, valve operation, and lead surgeon to assess high resource utilization. Results: MICS was correlated with a significantly lower rate of high resource utilization (MICS, 31.25% [n = 115] vs FS 61.29% [n = 76]; P < .001). Median postoperative length of stay (MICS, 4 days [range, 3-6 days] vs FS, 6 days [range, 4 to 9 days]; P < .001) and direct cost (MICS, $22,900 [$19,500-$28,600] vs FS, $31,900 [$25,900-$50,000]; P < .001) were lower in the MICS group. FS patients were more likely to experience postoperative atrial fibrillation (P = .040) and renal failure (P = .027). Other outcomes did not differ between groups. Controlling for stratified Society of Thoracic Surgeons predicted risk of mortality, cardiac valve operation, and lead surgeon, FS demonstrated increased likelihood of high resource utilization (P < .001). Conclusions: MICS for left-heart valve pathology demonstrated improved postoperative outcomes and resource utilization.

6.
J Surg Res ; 292: 182-189, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37633247

ABSTRACT

INTRODUCTION: We sought to compare outcomes after early discharge in patients with and without predischarge diagnosis of arrhythmia following minimally invasive valve surgery (MIVS). MATERIALS AND METHODS: We retrospectively reviewed ambulatory electrocardiography (AECG) datasheets and medical records of patients discharged with 14-d AECG monitoring from our facility between October 2019 and March 2022 ≤ 3 d after MIVS. Baseline and clinical characteristics, arrhythmias during AECG monitoring, and 30-d adverse outcomes were reported for the population and stratified by presence or absence of predischarge arrhythmia. RESULTS: Of 41 patients discharged ≤3 d postoperatively of MIVS, 17 (41.5%) experienced predischarge arrhythmias and 24 (58.5%) did not. The population was predominantly male and White with a median age of 62 y [57, 70]. Baseline and clinical characteristics did not differ between subgroups. Most patients (92.7% [n = 38]) experienced one or more tachyarrhythmias during the AECG monitoring period. There were similar proportions of patients experiencing atrial fibrillation in both groups, but patients with predischarge arrhythmias had higher burden of atrial fibrillation on AECG monitoring (27.60% [6.57%, 100%] versus 1.65% [0.76%, 4.32%]; P = 0.004). The predischarge arrhythmia subgroup had higher proportions of patients experiencing nonsustained ventricular tachycardia but lower proportions experiencing supraventricular tachycardia. There were no mortalities within 30 d of surgery. Six (14.6%) patients were readmitted within 30 d with equal proportions of readmissions between subgroups (P = 0.662). CONCLUSIONS: Early discharge timelines and noninvasive monitoring techniques can allow patients to return to their normal activities quicker in the comfort of their own home with no increased risk of morbidity or mortality.

7.
J Thorac Dis ; 15(3): 1057-1062, 2023 Mar 31.
Article in English | MEDLINE | ID: mdl-37065559

ABSTRACT

Background: Establishing cardiopulmonary bypass remains critical to the successful repair of an acute type A aortic dissection. A recent trend away from femoral arterial cannulation has occurred in part due to concerns of stroke risk from retrograde perfusion to the brain. The purpose of this study was to determine if arterial cannulation site for aortic dissection repair impacts surgical outcomes. Methods: A retrospective chart review was performed at Rutgers Robert Wood Johnson Medical School from January 1st, 2011 to March 8th, 2021. Of the 135 patients included, 98 (73%) underwent femoral arterial cannulation, 21 (16%) axillary artery cannulation, and 16 (12%) direct aorta cannulation. The study variables included demographic data, cannulation site, and complications. Results: The mean age was 63.6±14 years, with no difference between the femoral, axillary, and direct cannulation groups. Eighty-four patients (62%) were male, with similar percentages amongst each group. The rates of bleeding, stroke, and mortality specifically due to the arterial cannulation did not significantly differ based on cannulation site. None of the patients had strokes that were attributable to cannulation type. No patients died as a direct complication of arterial access. The overall in-hospital mortality was 22%, similar between groups. Conclusions: This study found no statistically significant different in rates of stroke or other complications based on cannulation site. Femoral arterial cannulation thus remains a safe and efficient choice for arterial cannulation in the repair of acute type A aortic dissection.

8.
J Pharm Pract ; 36(4): 1035-1038, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35388725

ABSTRACT

Heparin purge solution is recommended to be used in Impella devices to prevent biomaterial buildup and subsequent device dysfunction. The use of sodium bicarbonate purge solution in an Impella device is described in two patients with heparin-induced thrombocytopenia (HIT). The first case details a patient with severe mitral regurgitation and cardiogenic shock who had an Impella CP placed who developed HIT. Heparin purge solution was replaced by sodium bicarbonate purge solution in addition to systemic direct thrombin inhibitor (DTI) initiation. There was no significant change in Impella purge pressure or flow over the 13 days of Impella use. The second case describes a patient who developed an acute myocardial infarction and subsequent cardiogenic shock for which an Impella CP was placed who also developed HIT. Heparin purge solution was replaced by sodium bicarbonate purge solution. There was no significant change in purge pressure, flow, or motor current spikes over 11 days of use. In conclusion, we describe the successful use of a novel sodium bicarbonate purge solution utilized in patients with HIT for Impella management alone and in combination with systemic direct thrombin inhibitor therapy. This resulted in no protein deposition in the device gaps or device dysfunction.


Subject(s)
Heart-Assist Devices , Thrombocytopenia , Humans , Anticoagulants/adverse effects , Sodium Bicarbonate/therapeutic use , Shock, Cardiogenic/chemically induced , Shock, Cardiogenic/therapy , Heart-Assist Devices/adverse effects , Heparin/adverse effects , Thrombocytopenia/therapy , Thrombocytopenia/prevention & control , Antithrombins/adverse effects , Treatment Outcome , Retrospective Studies
10.
J Cardiothorac Surg ; 17(1): 235, 2022 Sep 15.
Article in English | MEDLINE | ID: mdl-36109812

ABSTRACT

OBJECTIVE: Over the last two decades there has been an increase in the number of cardiac implantable electronic devices and consequently, there has also been an increased need for lead extractions. Fibrotic attachments develop between the lead and the venous and cardiac structures that may require the use of a laser to mobilize the lead. Cardiothoracic surgeons (CTS) have traditionally provided backup for surgical emergencies for these extractions. This study evaluates the surgical outcomes of patients undergoing transvenous laser lead extractions (TLE) and determines if CTS are still needed for backup. METHODS: A retrospective review of consecutive patients undergoing laser lead extractions at a single academic center. Lead extractions using only laser sheaths were analyzed. The clinical characteristics, complications, and mortality of the patients were evaluated. RESULTS: One hundred and twenty-one patients underwent TLEs from January 1st, 2014 to December 31st, 2018. The majority were male (N = 80, 66.1%), and the average age was 66.48 ± 14 years. The indication for removal was either laser lead malfunction or infection. A total of 30 patients (24.8%) had complications postoperatively including wound hematomas, superficial infections, and arrhythmias. The average length of stay was 9 ± 12 for all the patients in the study. 2 patients (1.6%) had injuries that required emergency surgical repair with injuries to the posterior superior vena cava and right ventricle. Both patients survived the initial injury with one patient was discharged home on day 4 and the other succumbing to his injuries on postoperative day 20. CONCLUSION: Although the incidence of surgical emergencies is rare the morbidity and mortality for TLE require that surgical backup be available.


Subject(s)
Defibrillators, Implantable , Aged , Aged, 80 and over , Cardiopulmonary Bypass , Defibrillators, Implantable/adverse effects , Device Removal/adverse effects , Emergencies , Female , Humans , Lasers , Male , Middle Aged , Vena Cava, Superior/surgery
11.
Int J Artif Organs ; 45(5): 470-477, 2022 May.
Article in English | MEDLINE | ID: mdl-35365063

ABSTRACT

BACKGROUND: To derive and validate a risk score that accurately predicts 1-year mortality after heart transplantation (HT) in patients bridged to transplant (BTT) with a left ventricular assist device (LVAD). METHODS: The UNOS database was queried to identify patients BTT with an LVAD between 2008 and 2018. Patients with ⩾1-year follow up were randomly divided into derivation (70%) and validation (30%) cohorts. The primary endpoint was 1-year mortality. A simple additive risk score was developed based on the odds of 1-year mortality after HT. Risk groups were created, and survival was estimated and compared. RESULTS: A total of 7759 patients were randomly assigned to derivation (n = 5431) and validation (n = 2328) cohorts. One-year post-transplant mortality was 9.8% (n = 760). A 33-point scoring was created from six recipient variables and two donor variables. Risk groups were classified as low (0-5), intermediate (6-10), and high (>10). In the validation cohort, the predicted 1-year mortality was significantly higher in the high-risk group than the intermediate and low-risk groups, 14.7% versus 9% versus 6.1% respectively (log-rank test: p < 0.0001). CONCLUSION: The BTT-LVAD Score can serve as a clinical decision tool to guide therapeutic decisions in advanced heart failure patients.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Heart Failure/surgery , Heart Transplantation/adverse effects , Humans , Retrospective Studies , Risk Factors , Treatment Outcome
13.
Catheter Cardiovasc Interv ; 99(4): 1243-1250, 2022 03.
Article in English | MEDLINE | ID: mdl-34851550

ABSTRACT

OBJECTIVE: The purpose of this study is to assess the utility of ambulatory cardiac monitoring (ACM) in detecting delayed advanced conduction abnormalities (DACA) and associated 30-day mortality. BACKGROUND: DACA are well-known complications of TAVR and may be associated with post-discharge mortality within 30-days. METHODS: Between October 2019 and October 2020, TAVR patients who were discharged home without a permanent pacemaker (PPM) were monitored with an ACM device for 14-days. The incidence of DACA at follow up, mortality and readmission within 30-days were investigated. The risk of DACA was assessed in three patient categories based on a composite of their 12-lead electrocardiogram (ECG) data. Group I: Normal pre-TAVR, periprocedural, and discharge ECGs. Group II: Normal pre-TAVR and abnormal subsequent ECGs. Group III. Abnormal baseline and abnormal subsequent ECGs. RESULTS: Among 340 TAVR patients, 248 were discharged home with an ACM device. The overall incidence of DACA was 7% (n = 17), of whom 4% (n = 10) required a PPM. Mortality and readmission between discharge and 30 days was 0% and 8.3%, respectively. Stratification of patients identified 96 (38.7%) patients in Group I: 50 (20%) in Group II, and 102 (41%) in Group III. The incidence of DACA requiring a PPM was 0% in Group I, 4% (n = 2) in Group II, and 8.5% (n = 8) in Group III (p < 0.004). CONCLUSIONS: In TAVR patients who were discharged home with ACM, none died between discharge and 30-days. For those with normal baseline, perioperative and discharge ECG, there were no events of DACA at 14-days.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aftercare , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Arrhythmias, Cardiac/etiology , Cardiac Pacing, Artificial/adverse effects , Electrocardiography/adverse effects , Humans , Pacemaker, Artificial/adverse effects , Patient Discharge , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
14.
Ann Thorac Surg ; 114(1): 91-97, 2022 07.
Article in English | MEDLINE | ID: mdl-34419437

ABSTRACT

BACKGROUND: We investigated patient outcomes in relation to their postoperative length of stay after minimally invasive valve surgery. METHODS: All adults who survived elective, uncomplicated minimally invasive aortic or mitral valve surgery at a single center between 2012 and 2019 were classified by postoperative length of stay: early discharge (≤3 days) or late discharge (>3 days). The trend in early discharge was investigated over the study period, predictors of early discharge were identified using multivariate logistic regression modeling, and 1:1 propensity score matching was used to determine which patients in the late-discharge cohort had similar health to patients discharged early. Adjusted outcomes of 30-day mortality, readmission, and direct costs were analyzed. RESULTS: Among 1262 consecutive patients undergoing minimally invasive valve surgery, 618 were elective and uncomplicated, 25% (n = 162) of whom were discharged early. The proportion of early-discharge patients increased over time (P for trend < .05). A history of congestive heart failure, stroke, or smoking and higher Society of Thoracic Surgeons predictive risk of mortality score negatively predicted early discharge (P < .05). Propensity score matching identified 101 (22%) late-discharge patients comparable with early-discharge patients. Adjusted 30-day mortality and readmission rates were comparable between cohorts. The median direct costs per patient ($20,046 vs $22,124, P < .05) were significantly lower in the early-discharge cohort. CONCLUSIONS: In well-selected patients early discharge after minimally invasive valve surgery was associated with lower costs but comparable postoperative outcomes. About one-fifth of patients who remain in the hospital beyond postoperative day 3 may be candidates for earlier discharge.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Adult , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Length of Stay , Minimally Invasive Surgical Procedures/adverse effects , Mitral Valve/surgery , Patient Discharge , Retrospective Studies , Treatment Outcome
15.
J Card Surg ; 37(1): 117-123, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34791705

ABSTRACT

BACKGROUND: Minimally invasive heart valve surgery has previously been shown to be safe and feasible in obese patients. Within this population, we investigated the effect of obesity class on the patient outcomes of minimally invasive aortic valve replacement (mini-AVR). METHODS: A single-center retrospective cohort study of consecutive patients with obese body mass indices (BMIs) who underwent mini-AVR between 2012 and 2020. Patients were stratified into three groups according to Centers for Disease Control and Prevention adult obesity classifications: Class I (BMI: 30.0-<35.0), Class II (BMI: 35.0-<40.0), and Class III (BMI ≥ 40.0). The primary outcomes were postoperative length of stay (LOS), 30-day mortality, and direct cost. RESULTS: Among 206 obese patients who underwent mini-AVR, LOS (Class I 5 [3-7] vs. Class II 6 [5-7] vs. Class III 6 [5-7] days; p = .056), postoperative 30-day mortality (Class I 2.44% [n = 3] vs. Class II 4.44% [n = 2] vs. Class III 7.89% [n = 3]; p = .200), and costs (Class I $24,118 [$20,237-$29.591] vs. Class II $22,215 [$18,492-$28,975] vs. Class III $24,810 [$20,245-$32,942] USD; p = .683) did not differ between obesity class cohorts. CONCLUSIONS: Mini-AVR is safe and feasible to perform for obese patients regardless of their obesity class. Patients with obesity should be afforded the option of minimally invasive aortic valve surgery regardless of their obesity class.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Adult , Aortic Valve/surgery , Body Mass Index , Humans , Minimally Invasive Surgical Procedures , Obesity/complications , Retrospective Studies , Sternotomy , Treatment Outcome
16.
JTCVS Open ; 12: 84-102, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36590734

ABSTRACT

Objective: Bioprosthetic surgical aortic valve replacement remains an important treatment option in the era of transcatheter interventions. Real-world outcomes are not well characterized because of limited prospective follow-up studies. We present the 10-year clinical outcomes of Medicare beneficiaries undergoing surgical aortic valve replacement with a contemporary supra-annular porcine valve. Methods: This is a single-arm observational study using Medicare fee-for-service claims data. De-identified patients undergoing surgical aortic valve replacement with the Epic Supra valve (Abbott) in the United States between January 1, 2008, and December 31, 2019, were selected by International Classification of Diseases 9th and 10th Revision procedure codes and then linked to a manufacturer device tracking database. All-cause mortality, heart failure rehospitalization, and aortic valve reintervention (surgical or transcatheter valve-in-valve) were evaluated at 10 years using the Kaplan-Meier method. Results: Among 272,591 Medicare beneficiaries undergoing surgical aortic valve replacement during the study period, 11,685 received the Epic Supra valve, of whom 51.6% (6029) had underlying heart failure. Mean age was 76 ± 7 years. Survival at 10 years in patients without preoperative heart failure was 43.5% (95% confidence interval, 41.8-45.2) compared with 24.1% (95% confidence interval, 22.6-25.5) for patients with heart failure (P < .001). The 10-year freedom from heart failure rehospitalization was 64.0% (95% confidence interval, 62.6-65.3). Freedom from aortic valve reintervention was 94.6% (95% confidence interval, 93.8-95.3) at 10 years. Conclusions: This real-world nationwide study of US Medicare beneficiaries receiving the Epic Supra valve demonstrates more than 94% freedom from all-cause valve reintervention and 64% freedom from heart failure rehospitalization at 10 years postimplant. Long-term survival and heart failure rehospitalization in this population with aortic valve disease undergoing surgical aortic valve replacement were found to be impacted by underlying heart failure.

17.
JACC Cardiovasc Interv ; 14(24): 2711-2722, 2021 12 27.
Article in English | MEDLINE | ID: mdl-34949396

ABSTRACT

OBJECTIVES: The aim of this study was to determine the impact of delayed high-degree atrioventricular block (HAVB) or complete heart block (CHB) after transcatheter aortic valve replacement (TAVR) using a minimalist approach followed by ambulatory electrocardiographic (AECG) monitoring. BACKGROUND: Little is known regarding the clinical impact of HAVB or CHB in the early period after discharge following TAVR. METHODS: A prospective, multicenter study was conducted, including 459 consecutive TAVR patients without permanent pacemaker who underwent continuous AECG monitoring for 14 days (median length of hospital stay 2 days; IQR: 1-3 days), using 2 devices (CardioSTAT and Zio AT). The primary endpoint was the occurrence of HAVB or CHB. Patients were divided into 3 groups: 1) no right bundle branch block (RBBB) and no electrocardiographic (ECG) changes; 2) baseline RBBB with no further changes; and 3) new-onset ECG conduction disturbances. RESULTS: Delayed HAVB or CHB episodes occurred in 21 patients (4.6%) (median 5 days postprocedure; IQR: 4-6 days), leading to PPM in 17 (81.0%). HAVB or CHB events were rare in group 1 (7 of 315 [2.2%]), and the incidence increased in group 2 (5 of 38 [13.2%]; P < 0.001 vs group 1) and group 3 (9 of 106 [8.5%]; P = 0.007 vs group 1; P = 0.523 vs group 2). No episodes of sudden or all-cause death occurred at 30-day follow-up. CONCLUSIONS: Systematic 2-week AECG monitoring following minimalist TAVR detected HAVB and CHB episodes in about 5% of cases, with no mortality at 1 month. Whereas HAVB or CHB was rare in patients without ECG changes post-TAVR, baseline RBBB and new-onset conduction disturbances determined an increased risk. These results would support tailored management using AECG monitoring and the possibility of longer hospitalization periods in patients at higher risk for delayed HAVB or CHB.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Electrocardiography, Ambulatory , Humans , Prospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
J Cardiothorac Surg ; 16(1): 290, 2021 Oct 09.
Article in English | MEDLINE | ID: mdl-34627305

ABSTRACT

BACKGROUND: Cardiogenic shock and cardiac arrest are life-threatening emergencies with high mortality rates. Veno-arterial extracorporeal membrane oxygenation (VA ECMO) and extracorporeal cardiopulmonary resuscitation (e-CPR) provide viable options for life sustaining measures when medical therapy fails. The purpose of this study is to determine the utilization and outcomes of VA ECMO and eCPR in patients that require emergent cardiac support at a single academic center. METHODS: A retrospective chart review of prospectively collected data was performed at an academic institution from January 1st, 2018 to June 30th, 2020. All consecutive patients who required VA ECMO were evaluated based on whether they underwent traditional VA ECMO or eCPR. The study variables include demographic data, duration on ECMO, length of stay, complications, and survival to discharge. RESULTS: A total of 90 patients were placed on VA ECMO for cardiac support with 44.4% (40) of these patients undergoing eCPR secondary to cardiac arrest and emergent placement on ECMO. A majority of the patients were male (n = 64, 71.1%) and the mean age was 58.8 ± 15.8 years. 44.4% of patients were transferred from outside hospitals for a higher level of care and 37.8% of patients required another primary therapy such as an Impella or IABP. The most common complication experienced by patients was bleeding (n = 41, 45.6%), which occurred less often in eCPR (n = 29, 58% vs. n = 12, 30%). Other complications included infections (n = 11, 12.2%), limb ischemia (n = 13, 14.4%), acute kidney injury (n = 17, 18.9%), and cerebral vascular accident (n = 4, 4.4%). The length of stay was longer for patients on VA ECMO (32.1 ± 40.7 days vs. 17.7 ± 18.2 days). Mean time on ECMO was 8.1 ± 8.3 days. Survival to discharge was higher in VA ECMO patients (n = 23, 46% vs. n = 8, 20%). CONCLUSION: VA ECMO provided an effective rescue therapy in patients in acute cardiogenic shock with a survival greater than the expected ELSO guidelines of 40%. While the survival of eCPR was lower than expected, this may reflect the severity of patient's condition and emphasizes the importance of careful patient selection and planning.


Subject(s)
Cardiopulmonary Resuscitation , Extracorporeal Membrane Oxygenation , Heart Arrest , Female , Heart Arrest/therapy , Humans , Male , Middle Aged , Retrospective Studies , Shock, Cardiogenic/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...