Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 2024 Aug 19.
Article in English | MEDLINE | ID: mdl-39161091

ABSTRACT

PURPOSE: To develop a generalized signal model for dual-module velocity-selective arterial spin labeling (dm-VSASL) that can integrate arbitrary saturation and inversion profiles. THEORY AND METHODS: A recently developed mathematical framework for single-module VSASL is extended to address the increased complexity of dm-VSASL and to model the use of realistic velocity-selective profiles in the label-control and vascular crushing modules. Expressions for magnetization difference, arterial delivery functions, labeling efficiency, and cerebral blood flow (CBF) estimation error are presented. Sources of error are examined and timing requirements to minimize quantification errors are derived. RESULTS: For ideal velocity-selective profiles, the predicted signals match those of prior work. With realistic profiles, a CBF-dependent estimation error can occur when velocity-selective inversion (VSI) is used for the labeling modules and velocity-selective saturation (VSS) is used for the vascular crushing module. The error reflects a mismatch between the leading and trailing edges of the delivery function for the second bolus and can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal saturation cutoff velocity. In the presence of B 0 $$ {\mathrm{B}}_0 $$ and B 1 $$ {\mathrm{B}}_1 $$ inhomogeneities, the labeling efficiency of dual-module VSI is more attenuated than that of dual-module VSS. CONCLUSION: The proposed signal model will enable researchers to more accurately assess and compare the performance of realistic dm-VSASL implementations and improve the quantification of dm-VSASL CBF measures.

2.
Magn Reson Med ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39011598

ABSTRACT

PURPOSE: To mitigate the B0/B1 + sensitivity of velocity-selective inversion (VSI) pulse trains for velocity-selective arterial spin labeling (VSASL) by implementing adiabatic refocusing. This approach aims to achieve artifact-free VSI-based perfusion imaging through single-pair label-control subtractions, reducing the need for the currently required four-pair dynamic phase-cycling (DPC) technique when using a velocity-insensitive control. METHODS: We introduce a Fourier-transform VSI (FT-VSI) train that incorporates sinc-modulated hard excitation pulses with MLEV-8-modulated adiabatic hyperbolic secant refocusing pairs. We compare performance between this train and the standard composite refocusing train, including with and without DPC, for dual-module VSI VSASL. We evaluate (1) simulated velocity-selective profiles and subtraction fidelity across a broad B0/B1 + range, (2) subtraction fidelity in phantoms, and (3) image quality, artifact presence, and gray-matter perfusion heterogeneity (as measured by the spatial coefficient of variation) in healthy human subjects. RESULTS: Adiabatic refocusing significantly improves FT-VSI robustness to B0/B1 + inhomogeneity for a single label-control subtraction. Subtraction fidelity is dramatically improved in both simulation and phantoms compared with composite refocusing without DPC, and is similar compared with DPC methods. In humans, marked artifacts seen with the non-DPC composite refocusing approach are eliminated, corroborated by significantly reduced gray-matter heterogeneity (via lower spatial coefficient of variation values). CONCLUSION: A novel VSASL labeling train using adiabatic refocusing pulses for VSI was found to reduce artifacts related to B0/B1 + inhomogeneity, thereby providing an alternative to DPC and its associated limitations, which include increased vulnerability to physiological noise and motion, reduced functional MRI applicability, and suboptimal data censoring.

3.
Behav Sci (Basel) ; 14(3)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38540534

ABSTRACT

INTRODUCTION: Despite evidence suggesting deleterious effects of cannabis and nicotine tobacco product (NTP) use on white matter integrity, there have been limited studies examining white matter integrity among users of both cannabis and nicotine. Further, updated white matter methodology provides opportunities to investigate use patterns on neurite orientation dispersion and density (NODDI) indices and subtle tissue changes related to the intra- and extra-neurite compartment. We aimed to investigate how cannabis and NTP use among adolescents and young adults interacts to impact the white matter integrity microstructure. MATERIALS AND METHODS: A total of 221 participants between the ages of 16 and 22 completed the Customary Drinking and Drug Use Record (CDDR) to measure substance use, and underwent a magnetic resonance imaging (MRI) session. Participants were divided into NTP-control and NTP groupings and cannabis-control and cannabis groupings (≥26 NTP/cannabis uses in past 6 months). Tract-Based Spatial Statistics (TBSS) and two-way between-subjects ANOVA investigated the effects of NTP use group, cannabis use group, and their interaction on fractional anisotropy (FA) and NODDI indices while controlling for age and biological sex. RESULTS: NTP use was associated with decreased FA values and increased orientation dispersion in the left anterior capsule. There were no significant effects of cannabis use or the interaction of NTP and cannabis use on white matter outcomes. DISCUSSION: NTP use was associated with altered white matter integrity in an adolescent and young adult sample. Findings suggest that NTP-associated alterations may be linked to altered fiber tract geometry and dispersed neurite structures versus myelination, as well as differential effects of NTP and cannabis use on white matter structure. Future work is needed to investigate how altered white matter is related to downstream behavioral effects from NTP use.

4.
Magn Reson Med ; 91(4): 1384-1403, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38181170

ABSTRACT

PURPOSE: To present a theoretical framework that rigorously defines and analyzes key concepts and quantities for velocity selective arterial spin labeling (VSASL). THEORY AND METHODS: An expression for the VSASL arterial delivery function is derived based on (1) labeling and saturation profiles as a function of velocity and (2) physiologically plausible approximations of changes in acceleration and velocity across the vascular system. The dependence of labeling efficiency on the amplitude and effective bolus width of the arterial delivery function is defined. Factors that affect the effective bolus width are examined, and timing requirements to minimize quantitation errors are derived. RESULTS: The model predicts that a flow-dependent negative bias in the effective bolus width can occur when velocity selective inversion (VSI) is used for the labeling module and velocity selective saturation (VSS) is used for the vascular crushing module. The bias can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal cutoff velocity of the vascular crushing module. CONCLUSION: The elements of the model are specified in a general fashion such that future advances can be readily integrated. The model can facilitate further efforts to understand and characterize the performance of VSASL and provide critical theoretical insights that can be used to design future experiments and develop novel VSASL approaches.


Subject(s)
Arteries , Magnetic Resonance Angiography , Spin Labels , Arteries/diagnostic imaging , Models, Theoretical , Acceleration , Cerebrovascular Circulation/physiology , Blood Flow Velocity/physiology