Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Int J Biol Macromol ; 281(Pt 1): 136233, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39362419

ABSTRACT

COVID-19 is an infectious disease caused by the SARS-CoV-2 virus, which rapidly spread worldwide and resulted in a pandemic. Efficient and sensitive detection techniques have been devised since the onset of the epidemic and continue to be improved at present. Due to the crucial role of the SARS-CoV-2 S1 protein in facilitating the virus's entry into cells, efforts in detection and treatment have primarily centered upon this protein. In this study, a rapid, ultrasensitive, disposable, easy-to-use, cost-effective next generation biosensor based on optimized aptamer (Optimer, OPT) was developed by using a disposable pencil graphite electrode (PGE) and applied for the impedimetric determination of SARS-CoV-2 S1 protein. The S1 protein interacted with the OPT in the solution phase and then immobilized onto the PGE surface. Subsequently, measurements using electrochemical impedance spectroscopy (EIS) were conducted in a solution containing a redox probe of 1 mM [Fe(CN)6]3-/4-. Under optimum conditions, the limit of detection (LOD) for the S1 protein in buffer medium at concentrations ranging from 101 to 106 ag/mL was calculated as 8.80 ag/mL (0.11 aM). The selectivity of the developed biosensor was studied against MERS-CoV-S1 protein (MERS) and Influenza Hemagglutinin antigen (HA). Furthermore, the application of the biosensor in artificial saliva medium is demonstrated. The LOD was also calculated in artificial saliva medium in the concentration range of 101-105 ag/mL and calculated as 2.01 ag/mL (0.025 aM). This medium was also used to assess the selectivity of optimized-aptamer based biosensor.

2.
Mikrochim Acta ; 191(8): 499, 2024 08 01.
Article in English | MEDLINE | ID: mdl-39088080

ABSTRACT

The main goal of our study is to demonstrate the applicability of the PPy-cryogel-modified electrodes for electrochemical detection of DNA. First, a polysaccharide-based cryogel was synthesized. This cryogel was then used as a template for chemical polypyrrole synthesis. This prepared polysaccharide-based conductive cryogel was used for electrochemical biosensing on DNA. Carrageenan (CG) and sodium alginate (SA) polysaccharides, which stand out as biocompatible materials, were used in cryogel synthesis. Electron transfer was accelerated by polypyrrole (PPy) synthesized in cryogel networks. A 2B pencil graphite electrode with a diameter of 2.00 mm was used as a working electrode. The prepared polysaccharide solution was dropped onto a working electrode as a support material to improve the immobilization capacity of biomolecules and frozen to complete the cryogelation step. PPy synthesis was performed on the electrodes whose cryogelation process was completed. In addition, the structures of cryogels synthesized on the electrode surface were characterized by thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Surface characterization of the modified electrodes was performed by energy-dispersive X-ray spectroscopy (EDX) analysis. Electrochemical determination of fish sperm DNA (fsDNA) was performed using a PPy-cryogel-modified electrode. The use of a porous 3D cryogel intermediate material enhanced the signal by providing a large surface area for the synthesis of PPy and increasing the biomolecule immobilization capacity. The detection limit was 0.98 µg mL-1 in the fsDNA concentration range 2.5-20 µg mL-1. The sensitivity of the DNA biosensor was estimated to 14.8 µA mM-1 cm-2. The stability of the biosensor under certain storage conditions was examined and observed to remain 66.95% up to 45 days.


Subject(s)
Alginates , Biosensing Techniques , Cryogels , DNA , Electrochemical Techniques , DNA/chemistry , Electrochemical Techniques/methods , Animals , Cryogels/chemistry , Alginates/chemistry , Biosensing Techniques/methods , Electrodes , Fishes , Male , Carrageenan/chemistry , Polysaccharides/chemistry , Polysaccharides/analysis , Pyrroles/chemistry , Spermatozoa/chemistry , Limit of Detection , Polymers
3.
Biosensors (Basel) ; 13(4)2023 Apr 04.
Article in English | MEDLINE | ID: mdl-37185533

ABSTRACT

Selective and sensitive detection of human activated protein C (APC) was performed herein by using carbon nanofiber (CNF) and ionic liquid (IL) composite modified pencil graphite electrode (PGE) and electrochemical impedance spectroscopy (EIS) technique. A carbon nanomaterial-based electrochemical aptasensor was designed and implemented for the first time in this study for the solution-phase interaction of DNA-Apt with its cognate protein APC as well as APC inhibitor aptamer-antidote pair. The applicability of this assay developed for the determination of APC in fetal bovine serum (FBS) and its selectivity against different proteins (protein C, thrombin, bovine serum albumin) was also examined. CNF-IL modified aptasensor specific to APC provided the detection limit as 0.23 µg/mL (equal to 3.83 nM) in buffer medium and 0.11 µg/mL (equal to 1.83 nM) in FBS. The duration of the proposed assay from the point of electrode modification to the detection of APC was completed within only 55 min.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Ionic Liquids , Nanocomposites , Nanofibers , Humans , Carbon , Ionic Liquids/chemistry , Electrochemical Techniques/methods , Protein C , Aptamers, Nucleotide/chemistry , Nanocomposites/chemistry , Serum Albumin, Bovine/chemistry , Electrodes , Biosensing Techniques/methods , Limit of Detection
4.
J Pharm Biomed Anal ; 230: 115385, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37054602

ABSTRACT

Three-dimensional (3D) printing technology has been applied in many areas. In recent years, new generation biosensors have been emerged with the progress on 3D printing technology (3DPT). Especially in the development of optical and electrochemical biosensors, 3DPT provides many advantages such as low cost, easy to manufacturing, being disposable and allow point of care testing. In this review, recent trends in the development of 3DPT based electrochemical and optical biosensors with their applications in the field of biomedical and pharmaceutical are examined. In addition, the advantages, disadvantages and future opportunities of 3DPT are discussed.


Subject(s)
Biosensing Techniques , Printing, Three-Dimensional , Pharmaceutical Preparations
5.
Turk J Chem ; 47(5): 864-887, 2023.
Article in English | MEDLINE | ID: mdl-38173734

ABSTRACT

The interaction of drugs with DNA is important for the discovery of novel drug molecules and for understanding the therapeutic effects of drugs as well as the monitoring of side effects. For this reason, many studies have been carried out to investigate the interactions of drugs with nucleic acids. In recent years, a large number of studies have been performed to electrochemically detect drug-DNA interactions. The fast, sensitive, and accurate results of electrochemical techniques have resulted in a leading role for their implementation in this field. By means of electrochemical techniques, it is possible not only to demonstrate drug-DNA interactions but also to quantitatively analyze drugs. In this context, electrochemical biosensors for drug-DNA interactions have been examined under different headings including anticancer, antiviral, antibiotic, and central nervous system drugs as well as DNA-targeted drugs. An overview of the studies related to electrochemical DNA biosensors developed for the detection of drug-DNA interactions that were reported in the last two decades in the literature is presented herein along with their applications and they are discussed together with their future perspectives.

6.
Diagnostics (Basel) ; 12(8)2022 Aug 17.
Article in English | MEDLINE | ID: mdl-36010342

ABSTRACT

After the COVID-19 pandemic started all over the world, great importance was placed on the development of sensitive and selective bioanalytical assays for the rapid detection of the highly pathogenic SARS-CoV-2 virus causing COVID-19 disease. In this present work, an impedimetric immunosensor was developed and applied for rapid, reliable, sensitive and selective detection of the SARS-CoV-2 S1 protein. To detect the SARS-CoV-2 virus, targeting of the spike S1 protein was achieved herein by using S1 protein-specific capture antibody (Cab-S1) immobilized screen-printed electrode (SPE) in combination with the electrochemical impedance spectroscopy (EIS) technique. With the impedimetric immunosensor, the detection limit for S1 protein in buffer medium was found to be 0.23 ng/mL (equal to 23.92 amol in 8 µL sample) in the linear concentration range of S1 protein from 0.5 to 10 ng/mL. In the artificial saliva medium, it was found to be 0.09 ng/mL (equals to 9.36 amol in 8 µL sample) in the linear concentration range of S1 protein between 0.1 and 1 ng/mL. The selectivity of the impedimetric immunosensor toward S1 protein was tested against influenza hemagglutinin antigen (HA) in the buffer medium as well as in artificial saliva.

7.
Talanta ; 244: 123422, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35395458

ABSTRACT

In this present study, an amperometric immunosensor was developed based on disposable screen-printed carbon electrode (SPCE) for specific and sensitive detection of SARS-CoV-2 S1 protein. Anti-SARS-CoV-2 S1 monoclonal antibody was firstly immobilized onto the electrode surface. Then, the sandwich complex was formed by addition of S1 protein, secondary antibody and HRP-IgG, respectively. Chronoamperometry measurements were done in the presence of TMB mediator and the detection of SARS-CoV-2 S1 protein was performed by using 10 µL sample. The limit of detection (LOD) was found to be 0.19 ng/mL (equals to 24.7 amol in 10 µL sample) in the linear range of 0.5-10 ng/mL obtained in buffer medium. The applicability of this assay was investigated in the linear range of 0.5-3 ng/mL S1 protein in artificial saliva medium with the LOD as 0.13 ng/mL (equals to 16.9 amol in 10 µL sample). The selectivity study was examined in the presence of Hemagglutinin antigen (HA) in both mediums; buffer and artificial saliva while resulting with the successful discrimination between S1 protein and HA. The one of ultimate goals of our study is to present the possible implementation of this assay to point of care (POC) analysis. Under this aim, this assay was performed in combination with a portable device that is the commercial electrochemical analyzer. Amperometric detection of S1 protein in the range of 0.5-5 ng/mL was also successfully performed in artificial saliva medium with a resulting LOD as 0.15 ng/mL (equals to 19.5 amol in 10 µL sample). In addition, a selectivity study was similarly carried out by portable device.


Subject(s)
Biosensing Techniques , COVID-19 , Antibodies, Viral , Biosensing Techniques/methods , COVID-19/diagnosis , Humans , Immunoassay/methods , SARS-CoV-2 , Saliva, Artificial
SELECTION OF CITATIONS
SEARCH DETAIL