Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Strength Cond Res ; 38(7): e349-e358, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38900183

ABSTRACT

ABSTRACT: Montgomery, TR Jr, Olmos, A, Sears, KN, Succi, PJ, Hammer, SM, Bergstrom, HC, Hill, EC, Trevino, MA, and Dinyer-McNeely, TK. Influence of blood flow restriction on neuromuscular function and fatigue during forearm flexion in men. J Strength Cond Res 38(7): e349-e358, 2024-To determine the effects of blood flow restriction (BFR) on the mean firing rate (MFR) and motor unit action potential amplitude (MUAPAMP) vs. recruitment threshold (RT) relationships during fatiguing isometric elbow flexions. Ten men (24.5 ± 4.0 years) performed isometric trapezoidal contractions at 50% maximum voluntary contraction to task failure with or without BFR, on 2 separate days. For BFR, a cuff was inflated to 60% of the pressure required for full brachial artery occlusion at rest. During both visits, surface electromyography was recorded from the biceps brachii of the dominant limb and the signal was decomposed. A paired-samples t test was used to determine the number of repetitions completed between BFR and CON. ANOVAs (repetition [first, last] × condition [BFR, CON]) were used to determine differences in MFR vs. RT and MUAPAMP vs. RT relationships. Subjects completed more repetitions during CON (12 ± 4) than BFR (9 ± 2; p = 0.012). There was no significant interaction (p > 0.05) between the slopes and y-intercepts during the repetition × condition interaction for MUAPAMP vs. MFR. However, there was a main effect of repetition for the slopes of the MUAPAMP vs. RT (p = 0.041) but not the y-intercept (p = 0.964). Post hoc analysis (collapsed across condition) indicated that the slopes of the MUAPAMP vs. RT during the first repetition was less than the last repetition (first: 0.022 ± 0.003 mv/%MVC; last: 0.028 ± 0.004 mv/%MVC; p = 0.041). Blood flow restriction resulted in the same amount of higher threshold MU recruitment in approximately 75% of the repetitions. Furthermore, there was no change in MFR for either condition, even when taken to task failure. Thus, BFR training may create similar MU responses with less total work completed than training without BFR.


Subject(s)
Electromyography , Forearm , Isometric Contraction , Muscle Fatigue , Muscle, Skeletal , Regional Blood Flow , Humans , Male , Muscle Fatigue/physiology , Adult , Isometric Contraction/physiology , Forearm/blood supply , Forearm/physiology , Young Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Regional Blood Flow/physiology , Blood Flow Restriction Therapy
2.
Eur J Appl Physiol ; 124(6): 1807-1820, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38236301

ABSTRACT

PURPOSE: To investigate the effects of blood flow restriction (BFR) on electromyographic amplitude (EMGRMS)-force relationships of the biceps brachii (BB) during a single high-load muscle action. METHODS: Twelve recreationally active males and eleven recreationally active females performed maximal voluntary contractions (MVCs), followed by an isometric trapezoidal muscle action of the elbow flexors at 70% MVC. Surface EMG was recorded from the BB during BFR and control (CON) visits. For BFR, cuff pressure was 60% of the pressure required to completely occlude blood at rest. Individual b (slope) and a terms (gain) were calculated from the log-transformed EMGRMS-force relationships during the linearly increasing and decreasing segments of the trapezoid. EMGRMS during the steady force segment was normalized to MVC EMGRMS. RESULTS: For BFR, the b terms were greater during the linearly increasing segment than the linearly decreasing segment (p < 0.001), and compared to the linearly increasing segment for CON (p < 0.001). The a terms for BFR were greater during the linearly decreasing than linearly increasing segment (p = 0.028). Steady force N-EMGRMS was greater for BFR than CON collapsed across sex (p = 0.041). CONCLUSION: BFR likely elicited additional recruitment of higher threshold motor units during the linearly increasing- and steady force-segment. The differences between activation and deactivation strategies were only observed with BFR, such as the b terms decreased and the a terms increased for the linearly decreasing segment in comparison to the increasing segment. However, EMGRMS-force relationships during the linearly increasing- and decreasing-segments were not different between sexes during BFR and CON.


Subject(s)
Elbow , Isometric Contraction , Muscle, Skeletal , Humans , Male , Female , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Elbow/physiology , Adult , Isometric Contraction/physiology , Regional Blood Flow/physiology , Electromyography/methods , Young Adult , Muscle Contraction/physiology
3.
Am J Hum Biol ; 36(1): e23978, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37563889

ABSTRACT

OBJECTIVES: (1) To examine the muscle thickness of various muscle groups of the body to estimate the absolute and relative skeletal muscle mass (SM) in competitive physique-based athletes (Bodybuilding, 212 Bodybuilding, Bikini, and Physique divisions) and (2) to compare values across various divisions of competition and to resistance trained and non-resistance trained individuals. METHODS: Eight competitive physique-based athletes (2 M and 6 F), two recreationally resistance trained (1 M and 1 F) and two non-resistance trained (1 M and 1 F) participants had muscle thickness measured by ultrasound at nine sites on the anterior and posterior aspects of the body. SM was estimated from an ultrasound-derived prediction equation and SM index was used to adjust for the influence of standing height (i.e., divided by height squared). RESULTS: SM values ranged from 19.6 to 60.4 kg in the eight competitive physique-based athletes and 16.1 to 32.6 kg in the four recreationally resistance trained and non-resistance trained participants. SM index ranged from 7.2 to 17.9 kg/m2 in the eight competitive physique-based athletes and 5.8 to 9.3 kg/m2 in the four recreationally resistance trained and non-resistance trained participants. CONCLUSION: Overall, varying magnitudes of SM and SM index were present across competitors and their respective divisions of bodybuilding. The Men's Open Bodybuilder in the present study had greater values of total SM and SM index compared to previously published values in the literature. Our data provides insight into the extent of SM present in this population and further extends the discussion regarding SM accumulation in humans.


Subject(s)
Body Height , Muscle, Skeletal , Male , Humans , Muscle, Skeletal/physiology , Athletes , Body Composition/physiology
4.
Eur J Appl Physiol ; 124(4): 1121-1129, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37889287

ABSTRACT

PURPOSE: To determined sex differences in absolute- and %-reductions in blood flow during intermittent muscular contractions as well as relationships between blood flow reductions and time to task failure (TTF). METHODS: Thirteen males (25 ± 4 years) and 13 females (22 ± 5 years) completed intermittent isometric trapezoidal forearm flexion at 50% maximal voluntary contraction until task failure. Doppler ultrasound was used to measure brachial artery blood flow (BABF) during the 12-s plateau phase and 12-s relaxation phase. RESULTS: Target torque was less in females than males (24 ± 5 vs. 42 ± 7 Nm; p < 0.001); however, TTF was not different between sexes (F: 425 ± 187 vs. M: 401 ± 158 s; p = 0.72). Relaxation-phase BABF at end-exercise was less in females than males (435 ± 161 vs. 937 ± 281 mL/min; p < 0.001) but contraction-phase BABF was not different (127 ± 46 vs. 190 ± 99 mL/min; p = 0.42). Absolute- and %-reductions in BABF by contraction were less in females than males (309 ± 146 vs. 747 ± 210 mL/min and 69 ± 10 vs. 80% ± 6%, respectively; both p < 0.01) and were associated with target torque independent of sex (r = 0.78 and 0.56, respectively; both p < 0.01). Absolute BABF reduction per target torque (mL/min/Nm) and TTF were positively associated in males (r = 0.60; p = 0.031) but negatively associated in females (r = - 0.61; p = 0.029). CONCLUSIONS: This study provides evidence that females incur less proportional reduction in limb blood flow from muscular contraction than males at a matched relative intensity suggesting females may maintain higher levels of muscle oxygen delivery and metabolite removal than males across the contraction-relaxation cycle of intermittent exercise.


Subject(s)
Muscle Fatigue , Muscle, Skeletal , Humans , Male , Female , Muscle, Skeletal/physiology , Muscle Fatigue/physiology , Sex Characteristics , Isometric Contraction/physiology , Muscle Contraction/physiology , Upper Extremity , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...