Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
S Afr Med J ; 113(10): 42-48, 2023 10 23.
Article in English | MEDLINE | ID: mdl-37881912

ABSTRACT

BACKGROUND: Point-of-care (POC) rapid recency testing can be used as a cost-effective tool to identify recently infected individuals (i.e. infected within the last 12 months) in near-real time, support epidemic control and identify hotspots for transmission as part of recent infection surveillance. OBJECTIVE: To evaluate the performance of the Asanté (HIV-1) rapid recency assay as a POC rapid test among blood donors in South Africa (SA). METHODS: The study was a cross-sectional and validity study of the Asanté HIV-1 Rapid Recency Assay performed on 715 consecutively archived plasma donor specimens from the SA National Blood Services to determine their recency and established HIV infection status. ELISA and rapid assays for HIV antibody detection were used as the reference-testing standard for confirming an infection, while the Maxim HIV-1 limiting antigen (LAg) avidity assay was used as a reference for comparing HIV recency status. Validity tests (sensitivity, specificity, negative and positive predictive values) and Cohen-Kappa tests of the agreement were conducted to compare the Asanté HIV-1 rapid recency assay results with the reference tests. RESULTS: Of the 715 studied blood samples, 63.1% (n=451/715) were confirmed to be HIV-positive based on the reference standard. The sensitivity and specificity of the Asanté HIV-1 rapid recency assay in diagnosing established HIV infection compared to the ELISA were 98.4% (95% CI 96.7 - 99.3) and 99.6% (95% CI 97.6 - 100), respectively. Compared with HIV rapid assay, the sensitivity and specificity of the Asanté HIV-1 rapid recency assay was 98.7% (95% CI 97.0 - 99.4) and 99.2% (95% CI 97.1 - 100), respectively. Of the 451 HIV-positive blood samples, 43% were confirmed as recent HIV infections by the Maxim HIV-1 LAg avidity assay. There was high agreement between the Asanté HIV-1 rapid recency assay and the Maxim HIV-1 LAg avidity assay (94.1%, k=0.879, p<0.0001). The sensitivity and specificity of the Asante HIV-1 assay was 89.4% (95% CI 84.0 - 93.0) and 97.7% (95% CI 94.8 - 99.0), respectively. CONCLUSION: The Asanté HIV-1 rapid recency assay test results demonstrated high accuracy (>90%) compared with the HIV ELISA and rapid assays for determining established infection and the Maxim HIV-1 LAg avidity assay for classifying recent HIV-1 infections. The assay's sensitivity for established infections was below the World Health Organization criteria (<99%) for POC devices. The Asanté HIV-1 rapid recency assay can be used to distinguish between recent and long-term infections, but may not be considered a POC test for determining HIV infection.


Subject(s)
HIV Infections , HIV Seropositivity , HIV-1 , Humans , HIV Infections/diagnosis , HIV Infections/epidemiology , Blood Donors , Cross-Sectional Studies , Point-of-Care Systems , South Africa/epidemiology , Sensitivity and Specificity
2.
J Microbiol Methods ; 97: 63-7, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24378358

ABSTRACT

Aflatoxins (AFs) are naturally occurring secondary metabolites. This toxin is principally produced by Aspergillus flavus and Aspergillus parasiticus in compound feeds worldwide. Compound feeds are feeds blended from various raw materials and additives. Contaminations of these feeds by AFs and its possible transmission into edible materials like milk, egg and organs of the body, are a serious problem. Expression of the Nor~1 (aflD) gene is the main factor responsible for AFs production. For this reason, a study was carried out to establish a correlation between levels of AFs and determinant gene (Nor~1) in South African compound feeds. To achieve this, compound feeds (n=30) were analyzed for Nor~1 gene using real time polymerase chain reaction (RT-PCR), while AFs levels in similar samples were estimated using high-performance liquid chromatography (HPLC) after an immune-affinity clean-up extraction procedure. Results indicated that AFs levels in positive samples ranged from 0.7 to 33.0 ppb. These levels generally did not correlate (R(2)=0.093) with those of Nor~1 gene in similar samples. Consequently, Nor~1 gene levels established via RT-PCR cannot be used as a predicting model for AFs in compound feeds. Only four of the feeds analyzed, specifically poultry feeds, contained levels of AFs above the regulatory limits of 10 ppb established in South Africa (S.A.). This should be considered unsafe when consumed on a continuous basis and may pose some health related problems especially when AFs are found together with other significant mycotoxins such as ochratoxins (OTs) and/or fumonisins (FBs).


Subject(s)
Aflatoxins/analysis , Alcohol Oxidoreductases/genetics , Animal Feed/analysis , Aspergillus/genetics , Food Microbiology , Fungal Proteins/genetics , Animals , NAD (+) and NADP (+) Dependent Alcohol Oxidoreductases , Real-Time Polymerase Chain Reaction , South Africa , Statistics as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...