Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters











Publication year range
1.
Acta Otolaryngol ; 144(5-6): 366-370, 2024.
Article in English | MEDLINE | ID: mdl-39250174

ABSTRACT

BACKGROUND: Previous studies found that in patients with profound hearing loss the NEO- personality factor Openness-to-experience is lowered. OBJECTIVE: Assuming that lowered Openness-to-experience may be due to limited access to sounds, we hypothesized that levels of Openness-to-experience would increase in these patients after cochlear implantation. MATERIAL AND METHODS: Twenty adults (mean age: 61 years; active CI users) with bilateral profound hearing loss were assessed with the NEO-Five-Factor-Inventory before cochlear implantation (pre) and five years later (post). RESULTS: No significant pre-post changes in personality were seen. Both before and five years after cochlear implantation, the sample had normal age- and gender-specific mean values on the factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness (T ≈ 50), but significantly lowered mean values on Openness-to-experience (T ≈ 42, p < 0.001). CONCLUSIONS AND SIGNIFICANCE: Cochlear implantation apparently has no (or at best very little) effect on Openness-to-experience in profoundly hearing impaired patients. While this study demonstrates once again, that high-grade hearing loss may be associated with less openness to new experiences, the reason for this association remains unclear.


Subject(s)
Cochlear Implantation , Personality , Humans , Middle Aged , Male , Female , Cochlear Implantation/psychology , Follow-Up Studies , Aged , Adult , Hearing Loss/psychology , Hearing Loss/surgery
2.
Article in English | MEDLINE | ID: mdl-39179912

ABSTRACT

OBJECTIVE: The goal of the study was to determine the short- and long-term outcome of health-related quality of life (HRQoL) in adults implanted with a Vibrant Soundbridge (VSB). METHODS: Twenty-one adults (8 females, 13 males; mean age at implantation: 57 ±10 years) who received a unilateral VSB for combined or conductive hearing loss, were administered two questionnaires: the Nijmegen Cochlear Implant Questionnaire (NCIQ) as a measure of hearing-specific HRQoL, and the Health Utility Index 3 (HUI 3) as a measure of generic HRQoL. The questionnaires were administered before implantation and three, six, 12 and 24 months after processor activation. RESULTS: The NCIQ total score raised significantly from 62 points before implantation to 76 points at three months after processor activation (p < 0.005). Thereafter, no significant increases occurred anymore. The HUI 3 multi-attribute score (MAUS) increased from 0.59 before implantation to 0.70 at three months and at six months after processor activation and then declined slightly to 0.68 at 24 months after processor activation. Similar values were observed with the HUI 3 single-attribute score (SAUS) of Hearing. The increases of the HUI 3 scores were not statistically significant, but all pre-post-implantation differences were clinically relevant. DISCUSSION: VSB recipients experienced a quick improvement of their HRQoL. After just three months of device use, a significant improvement of hearing-specific HRQoL and a clinically relevant improvement of generic HRQoL were seen. After three months, no essential changes of HRQoL occurred in our sample, suggesting that the achieved level of HRQoL may remain stable in the long term.

3.
J Vis Exp ; (208)2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38975780

ABSTRACT

Measuring the electrically evoked stapedius reflex during the fitting of cochlear implants (CIs) provides a reliable estimation of maximum comfort levels, resulting in the programming of the CI with high hearing comfort and good speech understanding. Detection of the stapedius reflex and the required stimulation level on each implant channel is already being performed during surgery, whereby intraoperative stapedius reflexes are observed through the surgical microscope. Intraoperative stapedius reflex detection is both an indicator that the auditory nerve is responding to electrical stimulation up to the brainstem and a test for the ability to perform postoperative stapedius reflex measurements. Postoperative stapedius reflex thresholds can be used to estimate upper stimulation levels in the CI fitting process. In particular, in children or patients unable to provide feedback on loudness perception, this method avoids inadequate stimulation with the CI, which can result in poor hearing performance. In addition, overstimulation can be avoided, which could even lead to refusal to use the device.


Subject(s)
Cochlear Implantation , Electric Stimulation , Stapedius , Humans , Stapedius/physiology , Cochlear Implantation/methods , Electric Stimulation/methods , Cochlear Implants , Reflex, Acoustic/physiology
4.
Eur Arch Otorhinolaryngol ; 281(9): 4757-4762, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38703197

ABSTRACT

PURPOSE: Perceived social support has been shown to positively correlate with health-related quality of life (HR-QoL) in a variety of conditions. This study investigated whether perceived social support is affecting HR-QoL of patients who receive a cochlear implant (CI) for deafness. METHODS: Eighty eight adults (56 males, 32 females; mean age: 60 years) with a uni- or bilateral CI for bilateral high-grade hearing loss were administered two questionnaires: a questionnaire for perceived social support (FSU-14) and the Nijmegen Cochlear Implant Questionnaire (NCIQ) for hearing-specific HR-QoL. Administration of the questionnaires occurred at four points in time: before implantation and three, 12 and 24 months after implant activation. RESULTS: The CI patients had quite high levels of perceived social support (mean percentile rank: 71), which remained stable at all four measurement points. Multivariate Analysis showed a significant interaction between perceived social support and HR-QoL indicating that higher perceived social support lead to higher improvement of HR-QoL after cochlear implantation. CONCLUSION: The CI patients in this study had higher than average levels of perceived social support, which did not change before and after cochlear implantation. Perceived social support and HR-QoL were related such that patients with high levels of perceived social support experienced greater improvement of their HR-QoL after cochlear implantation than patients with low levels of perceived social support. Based on this finding, perceived social support must be considered as an important factor for HR-QoL after cochlear implantation.


Subject(s)
Cochlear Implantation , Cochlear Implants , Quality of Life , Social Support , Humans , Male , Female , Middle Aged , Surveys and Questionnaires , Aged , Cochlear Implants/psychology , Adult , Cochlear Implantation/psychology , Aged, 80 and over , Deafness/psychology , Deafness/surgery , Deafness/rehabilitation
5.
HNO ; 72(8): 565-570, 2024 Aug.
Article in German | MEDLINE | ID: mdl-38424382

ABSTRACT

BACKGROUND: The Nijmegen Cochlear Implant Questionnaire (NCIQ) is a questionnaire for assessing hearing-specific quality of life in the context of cochlear implantation. Its length (60 items) makes it difficult to use in clinical practice, so a short version is desirable. The question arises as to which items should be selected for the short version. METHODS: The items were selected statistically using uncorrected item-total score correlation. Item selection was made based on datasets from three measurement points: before implantation and 3 and 12 months after processor activation. The items were selected according to the criterion that they were among the 40 items with the highest item-total score correlation at each of the three measurement points. RESULTS: Of the 60 items in the NCIQ, 25 met the criterion and were hence included in the short version. The short version yields similar scores as the long version at the postoperative timepoints; however, at the preoperative timepoint, the agreement of the scores is suboptimal. Split-half reliability and internal homogeneity of the short version are very good. CONCLUSION: The present study constitutes an initial positive evaluation of a short form of the NCIQ in terms of standard psychometric criteria. Application of the short form is associated with significantly reduced resources in terms of processing and evaluating.


Subject(s)
Cochlear Implants , Psychometrics , Quality of Life , Humans , Germany , Surveys and Questionnaires , Reproducibility of Results , Male , Female , Middle Aged , Sensitivity and Specificity , Cochlear Implantation , Treatment Outcome , Aged , Adult , Translating
6.
Otol Neurotol ; 44(3): e155-e159, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36649486

ABSTRACT

BACKGROUND: Only few studies assessed health-related quality of life (HRQoL) in cochlear implant (CI) patients for a period of more than 2 years. Some of these studies indicated that HRQoL might decrease after that period. The goal of our study was to see whether HRQoL indeed decreases or remains stable beyond 2 years after implant activation. METHODS: Twenty-five adults (11 women, 14 men; mean age at implantation: 60 ± 19 yr) with a unilateral CI for profound hearing loss were administered two questionnaires: the Nimjegen Cochlear Implant Questionnaire and the Health Utility Index 3 (HUI 3). The Nimjegen Cochlear Implant Questionnaire total score and the HUI single-attribute utility score of Hearing are measures of hearing-specific HRQoL, whereas the HUI multiattribute utility score is a measure of generic HRQoL. The questionnaires were administered before cochlear implantation and 1, 2, and 5 years after implant activation. RESULTS: Hearing-specific HRQoL was significantly improved at 1 year after implant activation and did not significantly change thereafter. Generic HRQoL also showed significant improvement at 1 year after implant activation, but deteriorated to a clinically relevant degree thereafter. CONCLUSIONS: The significant improvement of hearing-specific HRQoL obtained from cochlear implantation was fully maintained for up to 5 years after implantation. Generic HRQoL of our CI patients, however, fluctuated over time. The decrease of generic HRQoL is supposed to reflect general age-associated health declines.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Speech Perception , Adult , Male , Humans , Female , Quality of Life , Deafness/surgery , Hearing , Surveys and Questionnaires , Treatment Outcome
7.
Otol Neurotol ; 42(6): 799-805, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33625194

ABSTRACT

BACKGROUND: Single-sided deafness (SSD) is associated with a loss of binaural hearing. Major limitations of such patients are poor speech understanding in noisy environments and a lack of spatial hearing. To date, cochlear implantation is the most promising approach to overcome these deficits in this group of patients. OBJECTIVE: Cost-effectiveness analyses of cochlear implantation in patients with unilateral deafness. The model targets Austrian and German SSD patients who can either opt for treatment with a cochlear implant (CI) or decide against a CI and stay without any treatment. METHODS: A Markov model analyzed as microsimulation was developed using TreeAge Pro 2019 software. Pre- and postoperative utility values generated with HUI-3 were used to populate the model. Costs covered by the national insurance were considered. Costs and utilities were discounted by 3%. A model time horizon of 20 years was set. RESULTS: According to Austrian base-case analysis, the incremental cost-utility ratio (ICUR) was €34845.2 per quality-adjusted life year gained when comparing the "CI strategy" to the "no treatment strategy." The ICUR is marginally lower when adapting a German cost perspective-it was €31601.25 per quality-adjusted life year gained. Sensitivity analyses showed that the cost-effectiveness results are stable. Analyses also showed that the longer the time horizon is set, the more favorable the cost-effectiveness result is. CONCLUSIONS: Based on currently available data, the Markov microsimulation model suggests that cochlear implantation is cost-effective in Austrian and German patients with SSD if no other treatment option is considered within the model.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Loss, Unilateral , Speech Perception , Adult , Austria , Cost-Benefit Analysis , Deafness/surgery , Hearing Loss, Unilateral/surgery , Humans , Treatment Outcome
8.
J Deaf Stud Deaf Educ ; 26(1): 142-146, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33006603

ABSTRACT

Recent studies suggest that hearing loss in postlingually deafened adults may be associated with lowered levels of the personality factor Openness to experience. This study investigated whether cochlear implantation in postlingually deafened adults raises the level of Openness to experience. Fifty-five postlingually deafened adults (mean age: 63 years) were assessed with the Neuroticism-Extraversion-Openness-Five-Factor-Inventory (NEO-FFI), a questionnaire capturing the five personality factors Extraversion, Openness to experience, Neuroticism, Agreeableness, and Conscientiousness. Personality assessment occurred before cochlear implantation and 24 months after implant activation. On factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness the mean scores of the sample were equal to population norms, both before and after cochlear implantation. On factor Openness to experience, the mean score was significantly lower before cochlear implantation, and remained so thereafter. Openness to experience may be reduced in some groups of deaf or hard of hearing persons. Cochlear implantation had no effect on any personality factor, at least not after two years of implant use.


Subject(s)
Cochlear Implantation , Deafness , Adult , Humans , Middle Aged , Personality , Surveys and Questionnaires
9.
Eur Arch Otorhinolaryngol ; 277(3): 695-704, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31776734

ABSTRACT

PURPOSE: To determine the 2-year outcome of health-related quality of life (HRQoL) in adults who received a cochlear implant (CI) for single-sided deafness (SSD). METHODS: Twenty adults (mean age at implantation: 47 ± 11 years) with SSD (PTA worse ear: 113 dB HL, PTA better ear: 14 dB HL) were administered the Nijmegen Cochlear Implant Questionnaire (NCIQ), and the Health Utility Index 3 (HUI 3). Questionnaire administration occurred before cochlear implantation and 3, 6, 12, and 24 months after implant activation. RESULTS: Of the 20 patients, 2 discontinued CI use within the observation period due to poor benefit. The NCIQ total score of the sample increased significantly over time (p = 0.003). The largest increase occurred within the first 3 months of CI use. Also, the HUI 3 multi-attribute utility score increased significantly (p = 0.03). The post-treatment increase of this score (+ 0.11 points) indicated that the gain in HRQoL was clinically relevant. Patients with a duration of deafness > 10 years had in all measures an equal HRQoL improvement than had patients with a duration of deafness < 10 years. CONCLUSION: Cochlear implantation led to significant improvement of hearing-specific and generic HRQoL in our patients. The improvement was seen after 3 or 6 months but did not increase further at later intervals. Patients with long-lasting SSD may be at higher risk of discontinuing CI use. However, if they adapt to the CI, they can experience an equal increase of HRQoL as patients with a short duration of SSD.


Subject(s)
Cochlear Implantation , Deafness , Hearing Loss, Unilateral , Quality of Life , Adult , Cochlear Implants , Deafness/etiology , Deafness/surgery , Female , Health Care Surveys , Hearing Loss, Unilateral/etiology , Hearing Loss, Unilateral/surgery , Humans , Male , Middle Aged , Retrospective Studies , Speech Perception , Time Factors , Treatment Outcome
10.
Ear Hear ; 40(2): 418-425, 2019.
Article in English | MEDLINE | ID: mdl-29939862

ABSTRACT

BACKGROUND: Studies have shown that cochlear implants improve deaf patients' hearing-related quality of life (hrQoL), but the degree of improvement varies considerably between patients. This study investigated whether personality factors contribute to hrQoL outcome after cochlear implantation. METHOD: Fifty adult patients with postlingual hearing loss who received a unilateral cochlear implant were administered the Neuroticism-Extraversion-Openness Five-Factor Inventory (NEO-FFI; a personality inventory) and the Nijmegen Cochlear Implant Questionnaire (NCIQ; a hrQoL questionnaire). The NEO-FFI was administered only before implantation; the NCIQ was administered before implantation and 12 months after implant activation. A linear regression analysis was computed to detect whether NCIQ scores at 12 months were predicted by the NEO-FFI personality factors (i.e., Extraversion, Neuroticism, Openness to Experience, Agreeableness, and Conscientiousness) assessed before implantation. RESULTS: HrQoL scores had significantly improved 12 months after cochlear implantation in all subdomains of the NCIQ. Of the five personality factors, solely Neuroticism was negatively associated to the NCIQ subdomain self-esteem (ß = -0.34; p = 0.013) at 12 months after cochlear implantation. CONCLUSIONS: While significant improvement of hrQoL was seen 12 months after implant activation, this improvement was barely predicted by the Big-Five personality traits measured before implantation. Only Neuroticism was found to moderately influence postimplantation hrQoL in our patients, in the way that higher degrees of Neuroticism tend to go along with lower degrees of self-esteem (as conceptualized by the NCIQ). The failure to detect personality effects on hrQoL could partly be due to the low levels of Extraversion and Openness to Experience observed in our sample of patients with hearing loss.


Subject(s)
Cochlear Implantation , Deafness/rehabilitation , Hearing Loss, Unilateral/rehabilitation , Personality , Quality of Life/psychology , Adolescent , Adult , Aged , Aged, 80 and over , Cochlear Implants , Deafness/psychology , Extraversion, Psychological , Female , Hearing Loss, Unilateral/psychology , Humans , Linear Models , Male , Middle Aged , Neuroticism , Personality Inventory , Retrospective Studies , Treatment Outcome , Young Adult
11.
Int J Audiol ; 57(2): 150-155, 2018 02.
Article in English | MEDLINE | ID: mdl-29025322

ABSTRACT

OBJECTIVE: To study the long-term evolution of speech and intelligence in a child with partial deafness and normal hearing in the low frequencies after sequentially receiving cochlear implants in both ears. DESIGN: Retrospective chart review. STUDY SAMPLE: Male child aged 6 years was followed over a time period of four years. RESULTS: The paediatric patient had normal hearing up to 1 kHz and profound hearing loss at all higher frequencies symmetrical in both ears. Deprivation of high-frequency sounds resulted in retarded development of speech, language and cognitive skills. The choice for rehabilitation was cochlear implantation with the aim of preserving a considerable amount of low-frequency hearing. With natural hearing at low frequencies and electrical stimulation at high frequencies, the child was able to compensate most of his developmental deficits. Moreover, spatial hearing was almost normal. CONCLUSIONS: Electro-natural stimulation without amplification of the low frequencies (electro-natural hearing) provides access to the whole audible frequency range for children, who suffer from partial deafness in the high frequencies and are normal hearing at low frequencies. Such provision allows for regular speech development and favours the development of spatial hearing. The case report also demonstrates a strong impact on intellectual performance.


Subject(s)
Acoustic Stimulation/methods , Auditory Perception , Cognition , Deafness/therapy , Electric Stimulation Therapy/methods , Child , Child Development , Cochlear Implantation , Cochlear Implants , Combined Modality Therapy , Deafness/physiopathology , Deafness/psychology , Humans , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL