Circ Cardiovasc Interv ; : e013782, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39034924

ABSTRACT

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.

2.
J Am Heart Assoc ; : e035605, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023065

ABSTRACT

BACKGROUND: Thresholds of aortic valve calcification (AVC) to define hemodynamically moderate aortic stenosis (AS) from mild are lacking. We aimed to establish a novel grading classification of AVC as quantified by computed tomography and determine its prognostic value. METHODS AND RESULTS: This study included 915 patients with at least mild AS (mean age 70±12 years, 30% women) from a multicenter prospective registry. All patients underwent Doppler-echocardiography and noncontrast computed tomography within 3 months. Primary end point was the occurrence of all-cause death. Receiver operating characteristic curves analyses were used to determine the sensitivity and specificity of sex-specific thresholds of AVC to identify hemodynamically moderate AS. Optimal thresholds (ie, with best sensitivity/specificity) of AVC to distinguish moderate (aortic valve area 1.0-1.5 cm2 and mean gradient 20-39 mm Hg) from mild AS (aortic valve area >1.5 cm2 and mean gradient <20 mm Hg) were AVC ≥360 arbitrary units in women and ≥1037 arbitrary units in men. Based on the guidelines' thresholds for severe AS and the new thresholds in our study for moderate AS, 312 (34%) patients had mild, 253 (28%) moderate, and 350 (38%) severe AVC. During a mean follow-up of 5.6±3.9 years, 183 (27%) deaths occurred. In Cox multivariable models, AVC remained associated with an increased risk of death (adjusted hazard ratio per grade increase, 1.94 [95% CI, 1.53-2.56]; P<0.001). CONCLUSIONS: A novel grading classification of anatomic AS severity based on sex-specific thresholds of AVC provides significant prognostic value for predicting mortality. These findings support the complementarity of computed tomography-calcium scoring to Doppler-echocardiography to corroborate AS severity and enhance risk stratification in patients with AS.

3.
JAMA Cardiol ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39018080

ABSTRACT

Importance: There are currently no pharmacological treatments available to slow hemodynamic progression of aortic stenosis. Plasma lipoprotein(a) concentrations predict incident aortic stenosis but its association with hemodynamic progression is controversial. Objective: To determine the association between plasma lipoprotein(a) concentrations and hemodynamic progression in patients with aortic stenosis. Design, Settings and Participants: The study included patients with aortic stenosis from 5 longitudinal clinical studies conducted from March 2001 to March 2023 in Canada and the UK. Of 757 total patients, data on plasma lipoprotein(a) concentrations and rates of hemodynamic progression assessed by echocardiography were available for 710, who were included in this analysis. Data were analyzed from March 2023 to April 2024. Exposure: Cohort-specific plasma lipoprotein(a) concentration tertiles. Main Outcomes and Measures: Hemodynamic aortic stenosis progression on echocardiography as assessed by annualized change in peak aortic jet velocity, mean transvalvular gradient, and aortic valve area. Results: Among the included patients, 497 (70%) were male and 213 (30%) were female. The mean (SD) age was 65.2 (13.1) years. Patients in the top lipoprotein(a) tertile demonstrated 41% (estimate, 1.41; 95% CI, 1.13-1.75) faster progression of peak aortic jet velocity and 57% (estimate, 1.57; 95% CI, 1.18-2.10) faster progression of mean transvalvular gradient than patients in the bottom tertile. There was no evidence of heterogeneity across the individual cohorts. Progression of aortic valve area was comparable between groups (estimate, 1.23; 95% CI, 0.71-2.12). Similar results were observed when plasma lipoprotein(a) concentrations were treated as a continuous variable. Conclusions and Relevance: In this study, higher plasma lipoprotein(a) concentrations were associated with faster rates of hemodynamic progression in patients with aortic stenosis. Lowering plasma lipoprotein(a) concentrations warrants further investigation in the prevention and treatment of aortic stenosis.

4.
Eur Heart J ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953786

ABSTRACT

BACKGROUND AND AIMS: Physical activity has proven effective in preventing atherosclerotic cardiovascular disease, but its role in preventing degenerative valvular heart disease (VHD) remains uncertain. This study aimed to explore the dose-response association between moderate to vigorous physical activity (MVPA) volume and the risk of degenerative VHD among middle-aged adults. METHODS: A full week of accelerometer-derived MVPA data from 87 248 UK Biobank participants (median age 63.3, female: 56.9%) between 2013 and 2015 were used for primary analysis. Questionnaire-derived MVPA data from 361 681 UK Biobank participants (median age 57.7, female: 52.7%) between 2006 and 2010 were used for secondary analysis. The primary outcome was the diagnosis of incident degenerative VHD, including aortic valve stenosis (AS), aortic valve regurgitation (AR), and mitral valve regurgitation (MR). The secondary outcome was VHD-related intervention or mortality. RESULTS: In the accelerometer-derived MVPA cohort, 555 incident AS, 201 incident AR, and 655 incident MR occurred during a median follow-up of 8.11 years. Increased MVPA volume showed a steady decline in AS risk and subsequent AS-related intervention or mortality risk, levelling off beyond approximately 300 min/week. In contrast, its association with AR or MR incidence was less apparent. The adjusted rates of AS incidence (95% confidence interval) across MVPA quartiles (Q1-Q4) were 11.60 (10.20, 13.20), 7.82 (6.63, 9.23), 5.74 (4.67, 7.08), and 5.91 (4.73, 7.39) per 10 000 person-years. The corresponding adjusted rates of AS-related intervention or mortality were 4.37 (3.52, 5.43), 2.81 (2.13, 3.71), 1.93 (1.36, 2.75), and 2.14 (1.50, 3.06) per 10 000 person-years, respectively. Aortic valve stenosis risk reduction was also observed with questionnaire-based MVPA data [adjusted absolute difference Q4 vs. Q1: AS incidence, -1.41 (-.67, -2.14) per 10 000 person-years; AS-related intervention or mortality, -.38 (-.04, -.88) per 10 000 person-years]. The beneficial association remained consistent in high-risk populations for AS, including patients with hypertension, obesity, dyslipidaemia, and chronic kidney disease. CONCLUSIONS: Higher MVPA volume was associated with a lower risk of developing AS and subsequent AS-related intervention or mortality. Future research needs to validate these findings in diverse populations with longer durations and repeated periods of activity monitoring.

5.
Article in English | MEDLINE | ID: mdl-38972614

ABSTRACT

IMPORTANCE: Guidelines recommend the use of Dobutamine stress echocardiography (DSE) in patients with low-gradient aortic stenosis (AS) and left ventricular ejection fraction (LVEF) <50%. However, a paucity exists in DSE data when LVEF>35%. OBJECTIVE: To examine the diagnostic accuracy of DSE, in patients with low-gradient AS with a wide range of LVEF and to examine the interaction between the diagnostic accuracy of DSE and LVEF. DESIGN, SETTING AND PARTICIPANTS: Patients with mean-gradient<40 mmHg, AVA<1.0 cm2, and stroke volume index≤35 mL/m2 undergoing DSE and Cardiac Computer Tomography (C-CT) were identified from three prospectively collected patient cohorts, and stratified according to LVEF; LVEF<35%, LVEF 35-50% & LVEF>50%. EXPOSURE: DSE and C-CT was performed on patients with low-gradient AS MAIN OUTCOMES AND MEASURES: Severe AS was defined as AVC score ≥2000 AU among men, and ≥1200 AU for women on C-CT. RESULTS: Of 221 patients included in the study, 78 (35%) presented with LVEF<35%, 67 (30%) with LVEF 35-50%, and 76 (34%) with LVEF>50%. Mean-gradient and Vmax during DSE showed significantly diagnostic heterogeneity between LVEF groups, being most precise when LVEF<35% (both AUC=0.90), albeit with optimal thresholds of 30 mmHg & 377 cm/s, and a limited diagnostic yield in patients with LVEF≥35% (AUC=0.67 & 0.66 in LVEF 35-50% and AUC=0.65 & 0.60 in LVEF≥50%). Using guideline thresholds led to a sensitivity/specificity of 49%/84% for all patients with LVEF<50%. CONCLUSION AND RELEVANCE: While DSE is safe and leads to an increase in stroke volume in patients with low-gradient AS regardless of LVEF, the association between DSE gradients and AS severity assessed by C-CT demonstrates important heterogeneity depending on LVEF, with highest accuracy in patients with LVEF<35%.

6.
EuroIntervention ; 20(14): e845-e864, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39007831

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is now utilised as a less invasive alternative to surgical aortic valve replacement (SAVR) across the whole spectrum of surgical risk. Long-term durability of the bioprosthetic valves has become a key goal of TAVI as this procedure is now considered for younger and lower-risk populations. The purpose of this article is to present a state-of-the-art overview on the definition, aetiology, risk factors, mechanisms, diagnosis, clinical impact, and management of bioprosthetic valve dysfunction (BVD) and failure (BVF) following TAVI with a comparative perspective versus SAVR. Structural valve deterioration (SVD) is the main factor limiting the durability of the bioprosthetic valves used for TAVI or SAVR, but non-structural BVD, such as prosthesis-patient mismatch and paravalvular regurgitation, as well as valve thrombosis or endocarditis may also lead to BVF. The incidence of BVF related to SVD or other causes is low (<5%) at midterm (5- to 8-year) follow-up and compares favourably with that of SAVR. The long-term follow-up data of randomised trials conducted with the first generations of transcatheter heart valves also suggest similar valve durability in TAVI versus SAVR at 10 years, but these trials suffer from major survivorship bias, and the long-term durability of TAVI will need to be confirmed by the analysis of the low-risk TAVI versus SAVR trials at 10 years.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Factors , Bioprosthesis , Aortic Valve Stenosis/surgery , Prosthesis Failure , Treatment Outcome , Prosthesis Design , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects
7.
Article in English | MEDLINE | ID: mdl-38970592

ABSTRACT

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

8.
Article in English | MEDLINE | ID: mdl-39074545

ABSTRACT

OBJECTIVES: To assess the long-term outcomes of patients undergoing a Ross procedure in the context of a redo aortic valve surgery. METHODS: Prospectively collected data in all consecutive adults who underwent a Ross procedure were analyzed to compare the Ross procedure as a first surgery (RF) and as a redo (RP) surgery. RESULTS: Between 1990 and 2021, 395 Ross procedure were performed at our center (RF 345 and RP 50). A 2:1 propensity-match was performed (100 in RF group and 50 in RP group). The overall median follow-up is 11.6 [IQR 5.0-21.8] years and 100% complete. Survival was 87±12% in the RF group and 87±8% in the RP group at 20 years (p=0.30). The cumulative incidence of autograft reintervention was 6±3% and 21±6% in the RF group and 9±5% and 25±8% in the RP group at 10 and 20 years, respectively (p=0.74). Aortic valve gradient remained stable up to 20 years in both groups (p=0.42). The size of the sinuses of Valsalva tended to increase over time in the RF group, while it remained stable in the RP group (p=0.03). CONCLUSIONS: Ross procedure after a previous sternotomy for aortic valve surgery is safe and offers good long-term results. Patients undergoing redo aortic valve intervention have similar results compared to patients undergoing a primary Ross procedure with perhaps, a lower risk of autograft dilatation.

9.
Curr Cardiol Rep ; 2024 Jul 29.
Article in English | MEDLINE | ID: mdl-39073506

ABSTRACT

BACKGROUND: Obesity paradox in cardiovascular risk prediction has gained increasing attention in recent years. We aimed to investigate the impact of BMI on mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a multi-center retrospective analysis of patients with severe aortic stenosis undergoing TAVR. Patients were categorized into: Underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30) and obese (BMI ≥ 30). Multivariate cox-proportional hazard model was used to compare all-cause mortality. RESULTS: Total of 6688 patients included (175 underweight, 2252 normal weight, 2368 overweight and 1893 with obesity). Mean age of patients was 81 ± 8 years with 55% males. Patients with obesity had higher prevalence of comorbidities but a lower overall STS score. Mortality at 30-days post-TAVR was lower in the obese population compared to underweight, normal weight, and overweight patients (1.6% vs. 6.9%, 3.6%, and 2.8%, respectively, p < 0.001). Similarly, 3-year mortality was lowest in patients with obesity (17.1% vs. 28.9%, 24.5% and 18.6%, respectively, p < 0.001). On multivariate analysis, long term all-cause mortality at 3-years remained significantly lower in patients with obesity compared to underweight (HR 1.74, 95% CI: 1.30-2.40, p < 0.001) and normal weight (HR: 1.41, 95% CI:1.21-1.63, p < 0.001) but not in overweight patients (HR: 1.10, 95% CI:0.94-1.28, p = 0.240). CONCLUSION: In conclusion, patients with obesity have improved short and long term mortality following TAVR with an observed progressive increase in mortality with lower BMI ranges.

10.
J Am Heart Assoc ; 13(12): e035128, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38879450

ABSTRACT

Cardiac troponin is extensively used as a biomarker in modern medicine due to its diagnostic capability for myocardial injury, as well as its predictive and prognostic value for cardiac diseases. However, heterophile antibodies, antitroponin antibodies, and macrotroponin complexes can be observed both in seemingly healthy individuals and patients with cardiac diseases, potentially leading to false positive or disproportionate elevation of cTn (cardiac troponin) assay results and introducing discrepancies in clinical interpretations with impact on medical management. In this review article, we describe the possible mechanisms of cTn release and the sources of variations in the assessment of circulating cTn levels. We also explore the pathophysiological mechanisms underlying antitroponin antibody development and discuss the influence exerted by macrotroponin complexes on the results of immunoassays. Additionally, we explore approaches to detect these complexes by presenting various clinical scenarios encountered in routine clinical practice. Finally, unsolved questions about the development, prevalence, and clinical significance of cardiac autoantibodies are discussed.


Subject(s)
Autoantibodies , Biomarkers , Humans , Biomarkers/blood , Autoantibodies/blood , Heart Diseases/diagnosis , Heart Diseases/blood , Heart Diseases/immunology , Predictive Value of Tests , Troponin I/blood , Troponin I/immunology , Prognosis
11.
Curr Opin Cardiol ; 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38899782

ABSTRACT

PURPOSE OF REVIEW: Subclinical leaflet thrombosis (SLT) is often an incidental finding characterized by a thin layer of thrombus involving one, two or three leaflets, with typical appearance on multi-detector computed tomography (MDCT) of hypo-attenuating defect at the aortic side of the leaflet, also called hypo-attenuating leaflet thickening (HALT). SLT may occur following both transcatheter aortic replacement (TAVR) or biological surgical aortic valve replacement (SAVR). The aim of this review is to present an overview of the current state of knowledge on the incidence, diagnosis, clinical impact, and management of SLT following TAVR or SAVR. RECENT FINDINGS: SLT occurs in 10-20% of patients following TAVR and is somewhat more frequent than following SAVR (5-15%). SLT may regress spontaneously without treatment in about 50% of the cases but may also progress to clinically significant valve thrombosis in some cases. Oral anticoagulation with vitamin K antagonist is reasonable if SLT is detected by echocardiography and/or MDCT during follow-up and is generally efficient to reverse SLT. SLT is associated with mild increase in the risk of stroke but has no impact on survival. SLT has been linked with accelerated structural valve deterioration and may thus impact valve durability and long-term outcomes. SUMMARY: SLT is often an incidental finding on echocardiography or MDCT that occurs in 10-20% of patients following TAVR or 5-15% following biological SAVR and is associated with a mild increase in the risk of thrombo-embolic event with no significant impact on mortality but may be associated with reduced valve durability.

12.
Cardiol Clin ; 42(3): 373-387, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910022

ABSTRACT

Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest in long-term outcomes with the adoption of lifetime management in younger patients. To evaluate late outcomes in TAVI with SEV versus BEV, we performed a study-level meta-analysis of reconstructed time-to-event data published by May 31, 2023. We found no statistically significant difference in all-cause death after TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Treatment Outcome , Time Factors
13.
Ann Cardiothorac Surg ; 13(3): 211-223, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38841078

ABSTRACT

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthetic valve is too small in relation to the patient's body size. The effect of PPM on outcomes and valve durability have gained credibility, making this an important possibly preventable risk factor. Transcatheter aortic valve replacement (TAVR) generally has a lower incidence of PPM than surgical aortic valve replacement (SAVR). Current surgical literature and randomized trials show an association between severe PPM and mortality in patients with SAVR but there is less evidence for an association with TAVR. Differences in the incidence of PPM may be related to the methods and cutoffs for measuring mismatch. This review will discuss the current state of field and propose standardization of measurement methods which may more accurately risk stratify patients.

14.
JACC Adv ; 3(3): 100853, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38938841

ABSTRACT

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

15.
JACC Adv ; 3(2): 100761, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38939373

ABSTRACT

Background: A blood multimarker approach may be useful to enhance risk stratification in patients undergoing TAVI. Objectives: The objective of this study was to determine the prognostic value of multiple blood biomarkers in transcatheter aortic valve implantation (TAVI) patients. Methods: In this prospective study, several blood biomarkers of cardiovascular function, inflammation, and renal function were measured in 362 patients who underwent TAVI. The cohort was divided into 3 groups according to the number of elevated blood biomarkers (ie, ≥ median value for the whole cohort) for each patient before the procedure. Survival analyses were conducted to evaluate the association between blood biomarkers and risk of adverse event following TAVI. Results: During a median follow-up of 2.5 (IQR: 1.9-3.2) years, 34 (9.4%) patients were rehospitalized for heart failure, 99 (27%) patients died, and 113 (31.2%) met the composite endpoint of all-cause mortality or heart failure rehospitalization. Compared to patients with 0 to 3 elevated biomarkers (referent group), those with 4 to 7 and 8 to 9 elevated biomarkers had a higher risk of all-cause mortality (HR: 1.54 [95% CI: 0.84-2.80], P = 0.16, and HR: 2.81 [95% CI: 1.53-5.15], P < 0.001, respectively) and of the composite endpoint (HR: 1.65 [95% CI: 0.95-2.84], P = 0.07, and HR: 2.67 [95% CI: 1.52-4.70] P < 0.001, respectively). Moreover, adding the number of elevated blood biomarkers into the clinical multivariable model provided significant incremental predictive value for all-cause mortality (Net Reclassification Index = 0.71, P < 0.001). Conclusions: An increasing number of elevated blood biomarkers is associated with higher risks of adverse clinical outcomes following TAVI. The blood multimarker approach may be helpful to enhance risk stratification in TAVI patients.

17.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
18.
J Am Heart Assoc ; 13(13): e034723, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38904242

ABSTRACT

BACKGROUND: Cardiac amyloidosis (CA) is frequently found in older patients with aortic stenosis (AS). However, the prevalence of AS among patients with CA is unknown. The objective was to study the prevalence and prognostic impact of AS among patients with CA. METHODS AND RESULTS: We conducted a retrospective analysis of a prospective registry comprising 976 patients with native aortic valves who were confirmed with wild type transthyretin amyloid (ATTRwt), hereditary variant transthyretin amyloid (ATTRv), or immunoglobulin light-chain (AL) CA. CA patients' echocardiograms were re-analyzed focusing on the aortic valve. Multivariable Cox regression analysis was performed to assess the mortality risk associated with moderate or greater AS in ATTRwt CA. The crude prevalence of AS among patients with CA was 26% in ATTRwt, 8% in ATTRv, and 5% in AL. Compared with population-based controls, all types of CA had higher age- and sex-standardized rate ratios (SRRs) of having any degree of AS (AL: SRR, 2.62; 95% Confidence Interval (CI) [1.09-3.64]; ATTRv: SRR, 3.41; 95%CI [1.64-4.60]; ATTRwt: SRR, 10.8; 95%CI [5.25-14.53]). Compared with hospital controls, only ATTRwt had a higher SRR of having any degree of AS (AL: SRR, 0.97, 95%CI [0.56-1.14]; ATTRv: SRR, 1.27; 95%CI [0.85-1.44]; ATTRwt: SRR, 4.01; 95%CI [2.71-4.54]). Among patients with ATTRwt, moderate or greater AS was not associated with increased all-cause death after multivariable adjustment (hazard ratio, 0.71; 95%CI [0.42-1.19]; P=0.19). CONCLUSIONS: Among patients with CA, ATTRwt but not ATTRv or AL is associated with a higher prevalence of patients with AS compared with hospital controls without CA, even after adjusting for age and sex. In our population, having moderate or greater AS was not associated with a worse outcome in patients with ATTRwt.


Subject(s)
Aortic Valve Stenosis , Cardiomyopathies , Registries , Humans , Male , Female , Prevalence , Aged , Retrospective Studies , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Prognosis , Cardiomyopathies/epidemiology , Cardiomyopathies/mortality , Aged, 80 and over , Amyloid Neuropathies, Familial/epidemiology , Amyloid Neuropathies, Familial/mortality , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/genetics , Amyloid Neuropathies, Familial/diagnosis , Risk Factors , Echocardiography , Middle Aged , Amyloidosis/epidemiology , Amyloidosis/mortality , Amyloidosis/diagnosis , Immunoglobulin Light-chain Amyloidosis/epidemiology , Immunoglobulin Light-chain Amyloidosis/mortality , Immunoglobulin Light-chain Amyloidosis/complications , Prealbumin/genetics , Aortic Valve/diagnostic imaging
19.
JACC Adv ; 3(5): 100959, 2024 May.
Article in English | MEDLINE | ID: mdl-38939639

ABSTRACT

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

20.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

SELECTION OF CITATIONS