Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Dent ; 112: 103746, 2021 09.
Article in English | MEDLINE | ID: mdl-34265364

ABSTRACT

OBJECTIVES: High-speed dental instruments produce aerosol and droplets. The objective of this study was to evaluate aerosol and droplet production from a novel electric micromotor handpiece (without compressed air coolant) in real world clinical settings. METHODS: 10-minute upper incisor crown preparations were performed in triplicate in an open-plan clinic with mechanical ventilation providing 3.45 air changes per hour. A 1:5 ratio electric micromotor handpiece which allows water coolant without compressed air (Ti-Max Z95L, NSK) was used at three speeds: 60,000 (60 K), 120,000 (120 K), and 200,000 (200 K) revolutions per minute. Coolant solutions contained fluorescein sodium as a tracer (2.65 mmol L - 1). High-speed air-turbine positive control, and negative control conditions were conducted. Aerosol production was evaluated at 3 locations (0.5 m, 1.5 m, and 1.7 m) using: (1) an optical particle counter (OPC; 3016-IAQ, Lighthouse) to detect all aerosol; and (2) a liquid cyclone air sampler (BioSampler, SKC Ltd.) to detect aerosolised fluorescein, which was quantified by spectrofluorometric analysis. Settled droplets were detected by spectrofluorometric analysis of filter papers placed onto a rig across the open-plan clinic. RESULTS: Local (within treatment bay) settled droplet contamination was elevated above negative control for all conditions, with no difference between conditions. Settled droplet contamination was not detected above negative controls outside the treatment bay for any condition. Aerosol detection at 1.5 m and 1.7 m, was only increased for the air-turbine positive control condition. At 0.5 m, aerosol levels were highly elevated for the air-turbine, minimally elevated for 200 K and 120 K, and not elevated for 60 K. CONCLUSIONS: Electric micromotor handpieces which use water-jet coolant alone without compressed air produce localised (within treatment bay) droplet contamination, but are unlikely to produce aerosol contamination beyond the immediate treatment area (1.5 m), allowing them to be used safely in most open-plan clinic settings.


Subject(s)
Dental High-Speed Equipment , Aerosols
2.
J Clin Periodontol ; 48(8): 1093-1102, 2021 08.
Article in English | MEDLINE | ID: mdl-33817809

ABSTRACT

AIM: To assess the efficacy of a commercially available adjunctive phototherapy protocol ("Perio-1") in treatment of periodontitis. MATERIALS AND METHODS: In an examiner-blind, randomized, controlled, split-mouth, multicentre study, 60 periodontitis patients received root surface debridement (RSD) in sextants either alone (control sextants) or with the adjunctive phototherapy protocol (test sextants). Re-evaluation was performed at 6, 12 and 24 weeks. RESULTS: No statistically significant differences in mean (± standard deviation) clinical attachment level (CAL) change from baseline to week 24 were observed between test (-1.00 ± 1.16 mm) and control sextants (-0.87 ± 0.79 mm) at sites with probing pocket depths (PPDs) ≥5 mm ("deep sites") at baseline (p = .212). Comparisons between test and control sextants for all other parameters (CAL change at all sites, PPD change at deep sites/all sites, bleeding on probing, plaque scores), and for all change intervals, failed to identify any statistically significant differences. CONCLUSIONS: The phototherapy protocol did not provide any additional clinical benefits over those achieved by RSD alone. (German Clinical Trials Register DRKS00011229).


Subject(s)
Chronic Periodontitis , Periodontitis , Chronic Periodontitis/therapy , Dental Scaling , Humans , Multicenter Studies as Topic , Periodontal Index , Periodontitis/therapy , Phototherapy , Randomized Controlled Trials as Topic , Treatment Outcome
3.
J Dent ; 105: 103565, 2021 02.
Article in English | MEDLINE | ID: mdl-33359041

ABSTRACT

OBJECTIVES: Identify splatter/aerosol distribution from dental procedures in an open plan clinic and explore aerosol settling time after dental procedures. METHODS: In two experimental designs using simulated dental procedures on a mannequin, fluorescein dye was introduced: (1) into the irrigation system of an air-turbine handpiece; (2) into the mannequin's mouth. Filter papers were placed in an open plan clinic to collect fluorescein. An 8-metre diameter rig was used to investigate aerosol settling time. Analysis was by fluorescence photography and spectrofluorometry. RESULTS: Contamination distribution varied across the clinic depending on conditions. Unmitigated procedures have the potential to deposit contamination at large distances. Medium volume dental suction (159 L/min air) reduced contamination in the procedural bay by 53%, and in other areas by 81-83%. Low volume suction (40 L/min air) was similar. Cross-ventilation reduced contamination in adjacent and distant areas by 80-89%. In the most realistic model (fluorescein in mouth, medium volume suction), samples in distant bays (≥5 m head-to-head chair distance) gave very low or zero readings (< 0.0016% of the fluorescein used during the procedure). Almost all (99.99%) of the splatter detected was retained within the procedural bay/walkway. After 10 min, very little additional aerosol settled. CONCLUSIONS: Cross-infection risk from dental procedures in an open plan clinic appears small when bays are ≥ 5 m apart. Dilution effects from instrument water spray were observed, and dental suction is of benefit. Most settled aerosol is detected within 10 min indicating environmental cleaning may be appropriate after this. CLINICAL SIGNIFICANCE: Aerosols produced by dental procedures have the potential to contaminate distant sites and the majority of settled aerosol is detectable after 10 min. Dental suction and ventilation have a substantial beneficial effect. Contamination is likely to be minimal in open plan clinics at distances of 5 m or more.


Subject(s)
COVID-19 , Pandemics , Aerosols , Humans , SARS-CoV-2 , Suction
4.
J Oral Rehabil ; 48(1): 61-72, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32966633

ABSTRACT

BACKGROUND: Dental procedures often produce aerosol and splatter which have the potential to transmit pathogens such as SARS-CoV-2. The existing literature is limited. OBJECTIVE(S): To develop a robust, reliable and valid methodology to evaluate distribution and persistence of dental aerosol and splatter, including the evaluation of clinical procedures. METHODS: Fluorescein was introduced into the irrigation reservoirs of a high-speed air-turbine, ultrasonic scaler and 3-in-1 spray, and procedures were performed on a mannequin in triplicate. Filter papers were placed in the immediate environment. The impact of dental suction and assistant presence were also evaluated. Samples were analysed using photographic image analysis and spectrofluorometric analysis. Descriptive statistics were calculated and Pearson's correlation for comparison of analytic methods. RESULTS: All procedures were aerosol and splatter generating. Contamination was highest closest to the source, remaining high to 1-1.5 m. Contamination was detectable at the maximum distance measured (4 m) for high-speed air-turbine with maximum relative fluorescence units (RFU) being: 46,091 at 0.5 m, 3,541 at 1.0 m and 1,695 at 4 m. There was uneven spatial distribution with highest levels of contamination opposite the operator. Very low levels of contamination (≤0.1% of original) were detected at 30 and 60 minutes post-procedure. Suction reduced contamination by 67-75% at 0.5-1.5 m. Mannequin and operator were heavily contaminated. The two analytic methods showed good correlation (r = 0.930, n = 244, P < .001). CONCLUSION: Dental procedures have potential to deposit aerosol and splatter at some distance from the source, being effectively cleared by 30 minutes in our setting.


Subject(s)
COVID-19 , SARS-CoV-2 , Aerosols , Delivery of Health Care , Dental Scaling , Humans
5.
BDJ Open ; 6: 20, 2020.
Article in English | MEDLINE | ID: mdl-33083015

ABSTRACT

OBJECTIVE: To identify Muay Thai participants' attitudes towards use of mouth guards and their experiences of dental trauma. MATERIALS AND METHODS: An online cross-sectional survey was used to record Muay Thai participants' experiences and opinions regarding use of mouth guards. Participants were recruited from a Muay Thai gym in the north east of England. RESULTS: 92 respondents took part in the survey. 3% reported having never worn a mouth guard, whereas 61% reported routinely wearing mouth guards during a fight. Significantly more (73%) younger participants (18-29 years) reported wearing mouth guards during fights compared to those aged 30 years and older (50%) (p < 0.05). Mouth-formed ('boil and bite') were the most frequently used type of mouth guard (60% of users), followed by custom-made mouth guards provided by a dentist (32%). Factors such as protection, breathing, good fit and comfort were all considered important in the choice of mouth guard. 14% of respondents had experienced dental injuries, with chipped/broken teeth being the most common. CONCLUSION: Given the risk for dental trauma in Muay Thai, it is important that participants are advised regarding mouth guard use, particularly those that do not routinely wear them.

6.
Sci Rep ; 9(1): 11034, 2019 07 30.
Article in English | MEDLINE | ID: mdl-31363141

ABSTRACT

Periodontitis is an economically important disease which is highly prevalent worldwide. Current diagnostic approaches are time-consuming and require interpretation of multiple aspects of clinical and radiographic assessment. Chair-side monitoring of inflammatory mediators of periodontitis could provide immediate information about disease activity, which can inform patient management. We aimed to develop a novel prototype biosensor to measure salivary matrix metalloproteinase-8 (MMP-8) using specific antibodies and surface acoustic wave (SAW) technology. The analytical performance of the prototype biosensor was compared to standard enzyme-linked immunosorbent assay (ELISA) using unstimulated saliva samples obtained from patients with periodontitis before and after non-surgical treatment (N = 58), patients with gingivitis (N = 54) and periodontally healthy volunteers (N = 65). Receiver operator characteristic (ROC) analysis for distinguishing periodontitis from health revealed an almost identical performance between the sensor and ELISA assays (area under curve values (AUC): ELISA 0.93; SAW 0.89). Furthermore, both analytical approaches yielded readouts which distinguished between heath, gingivitis and periodontitis, correlated identically with clinical measures of periodontal disease and recorded similar post-treatment decreases in salivary MMP-8 in periodontitis. The assay time for our prototype device is 20 minutes. The prototype SAW biosensor is a novel and rapid method of monitoring periodontitis which delivers similar analytical performance to conventional laboratory assays.


Subject(s)
Biosensing Techniques/methods , Matrix Metalloproteinase 8/analysis , Periodontitis/metabolism , Saliva/chemistry , Acoustics , Adult , Antibodies/immunology , Diagnosis, Oral/methods , Female , Gingivitis/diagnosis , Gingivitis/metabolism , Humans , Immunoassay/methods , Male , Matrix Metalloproteinase 8/immunology , Middle Aged , Periodontitis/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...