Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 301
Filter
1.
J Clin Med ; 13(11)2024 May 31.
Article in English | MEDLINE | ID: mdl-38892985

ABSTRACT

Objectives: In recent years, minimally invasive approaches have been used with increasing frequency, even for more complex aortic procedures. However, evidence on the practicability and safety of expanding minimally invasive techniques from isolated operations of the ascending aorta towards more complex operations such as the hemiarch replacement is still scarce to date. Methods: A total of 86 patients undergoing elective surgical replacement of the ascending aorta with (n = 40) or without (n = 46) concomitant proximal aortic arch replacement between 2009 and 2023 were analyzed in a retrospective single-center analysis. Groups were compared regarding operation times, intra- and postoperative complications and long-term survival. Results: Operation times and ventilation times were significantly longer in the hemiarch replacement group. Despite this, no statistically significant differences between the two groups were observed for the duration of the ICU and hospital stay and postoperative complication rates. At ten-year follow-up, overall survival was 82.6% after isolated ascending aorta replacement and 86.3% after hemiarch replacement (p = 0.441). Conclusions: Expanding the indication for minimally invasive aortic surgery towards the proximal aortic arch resulted in comparable postoperative complication rates, length of hospital stay and overall long-term survival compared to the well-established minimally invasive isolated supracommissural ascending aorta replacement.

2.
J Clin Med ; 13(11)2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38893048

ABSTRACT

Background: Coronary artery disease is a major cause of death globally. Minimally invasive direct coronary artery bypass (MIDCAB), using a small left anterior thoracotomy, aims to provide a less invasive alternative to traditional procedures, potentially improving patient outcomes with reduced recovery times. Methods: This retrospective, non-randomized study analyzed 310 patients who underwent MIDCAB between July 1999 and April 2022. Data were collected on demographics, clinical characteristics, operative and postoperative outcomes, and follow-up mortality and morbidity. Statistical analysis was conducted using IBM SPSS, with survival curves generated via the Kaplan-Meier method. Results: The cohort had a mean age of 63.3 ± 10.9 years, with 30.6% females. The majority of surgeries were elective (76.1%), with an average operating time of 129.7 ± 35.3 min. The median rate of intraoperative blood transfusions was 0.0 (CI 0.0-2.0) Units. The mean in-hospital stay was 8.7 ± 5.5 days, and the median ICU stay was just one day. Early postoperative complications were minimal, with a 0.64% in-hospital mortality rate. The 6-month and 1-year mortalities were 0.97%, with a 10-year survival rate of 94.3%. There were two cases of perioperative myocardial infarction and no instances of stroke or new onset dialysis. Conclusions: The MIDCAB approach demonstrates significant benefits in terms of patient recovery and long-term outcomes, offering a viable and effective alternative for patients suitable for less invasive procedures. Our results suggest that MIDCAB is a safe option with favorable survival rates, justifying its consideration in high-volume centers focused on minimally invasive techniques.

3.
Front Immunol ; 15: 1404668, 2024.
Article in English | MEDLINE | ID: mdl-38903492

ABSTRACT

Heart transplantation is associated with major hurdles, including the limited number of available organs for transplantation, the risk of rejection due to genetic discrepancies, and the burden of immunosuppression. In this study, we demonstrated the feasibility of permanent genetic engineering of the heart during ex vivo perfusion. Lentiviral vectors encoding for short hairpin RNAs targeting beta2-microglobulin (shß2m) and class II transactivator (shCIITA) were delivered to the graft during two hours of normothermic EVHP. Highly efficient genetic engineering was indicated by stable reporter gene expression in endothelial cells and cardiomyocytes. Remarkably, swine leucocyte antigen (SLA) class I and SLA class II expression levels were decreased by 66% and 76%, respectively, in the vascular endothelium. Evaluation of lactate, troponin T, and LDH levels in the perfusate and histological analysis showed no additional cell injury or tissue damage caused by lentiviral vectors. Moreover, cytokine secretion profiles (IL-6, IL-8, and TNF-α) of non-transduced and lentiviral vector-transduced hearts were comparable. This study demonstrated the ex vivo generation of genetically engineered hearts without compromising tissue integrity. Downregulation of SLA expression may contribute to reduce the immunogenicity of the heart and support graft survival after allogeneic or xenogeneic transplantation.


Subject(s)
Genetic Vectors , Heart Transplantation , Histocompatibility Antigens Class I , Lentivirus , Animals , Lentivirus/genetics , Heart Transplantation/methods , Genetic Vectors/genetics , Swine , Histocompatibility Antigens Class I/genetics , Histocompatibility Antigens Class I/immunology , Histocompatibility Antigens Class I/metabolism , Perfusion/methods , Histocompatibility Antigens Class II/genetics , Histocompatibility Antigens Class II/metabolism , Histocompatibility Antigens Class II/immunology , beta 2-Microglobulin/genetics , Cytokines/metabolism , Genetic Engineering , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/immunology , Humans , RNA, Small Interfering/genetics , Graft Survival/immunology , Graft Survival/genetics , Endothelial Cells/metabolism , Endothelial Cells/immunology , Nuclear Proteins , Trans-Activators
4.
Diagnostics (Basel) ; 14(12)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38928674

ABSTRACT

BACKGROUND/OBJECTIVES: Infective prosthesis endocarditis (IE) following transcatheter aortic valve implantation (TAVI) presents significant management challenges, marked by high mortality rates. This study reviews our center's experience with surgical interventions for IE in patients post-TAVI, focusing on outcomes, challenges, and procedural complexities, and providing an overview of the limited literature surrounding this subject. METHODS: This study was executed as a comprehensive retrospective analysis, targeting the clinical outcomes of surgical treatment in patients presenting with PVE following TAVI procedures at our institution. From July 2017 to July 2022, we identified five patients who had previously undergone transfemoral transcatheter aortic valve implantation and were later diagnosed with PVE needing surgery, strictly adhering to the modified Duke criteria. RESULTS: All surgical procedures were reported successful with no intra- or postoperative mortality. Patients were predominantly male (80%), with an average age of 76 ± 8.6 years, presenting mostly with dyspnea (NYHA Class II). The mean follow-up was between 121 and 1973 days, with outcomes showing no occurrences of stroke, myocardial infarction, or major bleeding. One patient expired from unrelated causes 3.7 years post-surgery. The operative and postoperative protocols demonstrated effective disease management with enhanced survival and minimal complications. CONCLUSIONS: The surgical treatment of IE following TAVI, though challenging, can be successfully achieved with careful patient selection and a multidisciplinary approach. The favorable outcomes suggest that surgical intervention remains a viable option for managing this high-risk patient group. Our study also highlights the scarce literature available on this topic, suggesting an urgent need for more comprehensive research to enhance understanding and improve treatment strategies. Future studies with larger cohorts are needed to further validate these findings and refine surgical strategies for this growing patient population.

5.
ASAIO J ; 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38569184

ABSTRACT

Severe right heart failure, often overlooked and challenging to manage, has prompted a growing interest in innovative approaches to provide functional support. This study uses experimentation in large porcine models to introduce a novel prototype of a pulsatile mechanical circulatory support device and document its effects when deployed as a right ventricular assist device (RVAD). The pulsatile ventricular assist platform (pVAP), featuring a membrane pump driven by an intra-aortic balloon pump console, actively generates pulsatile flow to propel right ventricular blood into the pulmonary artery. This novel prototype demonstrates promising potential in addressing the challenges of right heart failure management. After preliminary in vitro assessments, the pVAP was tested on seven porcine models in a healthy state and after the induction of right ventricular failure. During the procedure, a set of standard (ie, standard-of-care) hemodynamic measurements was obtained. Additionally, invasive pressure-volume loop analysis was employed to examine left ventricular hemodynamics. Results indicated that activation of the pVAP during right ventricular failure significantly improved systemic hemodynamics and enhanced left ventricular function. This study sheds light on the potential of the pVAP in managing right heart failure.

6.
Innovations (Phila) ; 19(2): 196-203, 2024.
Article in English | MEDLINE | ID: mdl-38576096

ABSTRACT

In the evolving landscape of cardiac surgery, this article explores the potential of minimally invasive mitral valve replacement procedures as a viable alternative to conventional surgical techniques. Leveraging advancements in automated suturing devices and video endoscopy, our work aims to demonstrate that minimally invasive approaches can be applied across a broad spectrum of surgical scenarios. Herein we highlight preoperative diagnostics and operative techniques, with a focus on infra-axillary anterolateral minithoracotomy as the access point. Our technique utilizes technology from LSI SOLUTIONS® (Victor, NY, USA), including the RAM® Device for automated suturing, which has an ergonomic design and safety features. The device's capabilities are further enhanced by the SEW-EASY® Device, the RAM® RING, and the COR-KNOT MINI® Device, which streamline suture management and securement. This work outlines how these technological advancements can mitigate concerns about technical complexity and learning curves, thereby encouraging wider adoption of minimally invasive techniques. Clinical benefits may include reduced surgical trauma, quicker recovery, and cost-effectiveness, making it a compelling option in an era of aggressively promoted transcatheter interventions.


Subject(s)
Endoscopy , Heart Valve Prosthesis Implantation , Minimally Invasive Surgical Procedures , Mitral Valve , Suture Techniques , Humans , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Suture Techniques/instrumentation , Endoscopy/methods , Endoscopy/instrumentation , Thoracotomy/methods
7.
Adv Mater ; : e2313688, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38685135

ABSTRACT

Reliability of power supply for current implantable electronic devices is a critical issue for longevity and for reducing the risk of device failure. Energy harvesting is an emerging technology, representing a strategy for establishing autonomous power supply by utilizing biomechanical movements in human body. Here, a novel "Twistron energy cell harvester" (TECH), consisting of coiled carbon nanotube yarn that converts mechanical energy of the beating heart into electrical energy, is presented. The performance of TECH is evaluated in an in vitro artificial heartbeat system which simulates the deformation pattern of the cardiac surface, reaching a maximum peak power of 1.42 W kg-1 and average power of 0.39 W kg-1 at 60 beats per minute. In vivo implantation of TECH onto the left ventricular surface in a porcine model continuously generates electrical energy from cardiac contraction. The generated electrical energy is used for direct pacing of the heart as documented by extensive electrophysiology mapping. Implanted modified carbon nanotubes are applicable as a source for harvesting biomechanical energy from cardiac motion for power supply or cardiac pacing.

8.
Cells ; 13(7)2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38607074

ABSTRACT

The human respiratory system is susceptible to a variety of diseases, ranging from chronic obstructive pulmonary disease (COPD) and pulmonary fibrosis to acute respiratory distress syndrome (ARDS). Today, lung diseases represent one of the major challenges to the health care sector and represent one of the leading causes of death worldwide. Current treatment options often focus on managing symptoms rather than addressing the underlying cause of the disease. The limitations of conventional therapies highlight the urgent clinical need for innovative solutions capable of repairing damaged lung tissue at a fundamental level. Pluripotent stem cell technologies have now reached clinical maturity and hold immense potential to revolutionize the landscape of lung repair and regenerative medicine. Meanwhile, human embryonic (HESCs) and human-induced pluripotent stem cells (hiPSCs) can be coaxed to differentiate into lung-specific cell types such as bronchial and alveolar epithelial cells, or pulmonary endothelial cells. This holds the promise of regenerating damaged lung tissue and restoring normal respiratory function. While methods for targeted genetic engineering of hPSCs and lung cell differentiation have substantially advanced, the required GMP-grade clinical-scale production technologies as well as the development of suitable preclinical animal models and cell application strategies are less advanced. This review provides an overview of current perspectives on PSC-based therapies for lung repair, explores key advances, and envisions future directions in this dynamic field.


Subject(s)
Induced Pluripotent Stem Cells , Pluripotent Stem Cells , Pulmonary Fibrosis , Animals , Humans , Endothelial Cells , Induced Pluripotent Stem Cells/metabolism , Lung , Pulmonary Fibrosis/metabolism
10.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38532304

ABSTRACT

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Humans , Male , Allografts/surgery , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Endocarditis/surgery , Follow-Up Studies , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Reoperation , Routinely Collected Health Data , Female , Adolescent , Young Adult , Middle Aged
11.
J Heart Lung Transplant ; 43(7): 1126-1134, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38438087

ABSTRACT

BACKGROUND: Lung transplantation is the only curative treatment for patients with end-stage pulmonary fibrosis. It is still under debate whether over- or undersizing of lung allografts is preferably performed regarding the postoperative outcome. We therefore analyzed our data using predicted total lung capacity to compare size mismatches. METHODS: Patient records were retrospectively reviewed. Three groups were formed, 1 including patients with a donor-recipients pTLC ratio (DRPR) of <1.0 (undersized group), the second with a DRPR of ≥1.0 and <1.1 (size-matched group), and the third group with a DRPR of ≥1.1 (oversized group). Outcomes were evaluated using chi-square test and Kruskall-Wallis test as well as Kaplan-Meier analysis, competing risk analysis, and multivariable analysis, respectively. RESULTS: Between January 2010 and May 2023, among the 1501 patients transplanted at our institution, 422 (28%) patients were included, 26 (2%) patients forming the oversized group (median DRPR: 1.14), 101 (7%) patients forming the size-matched group (median DRPR: 1.03), and 296 (20%) patients forming the undersized group (median DRPR: 0.92). Patients from the oversized group had a higher PGD grade 3 rate at 24 (p < 0.001), 48 (p < 0.001), and 72 (p = 0.039) hours after transplantation as well as a higher in-hospital mortality compared to the undersized group (p = 0.033). The long-term survival was also better in the undersized group compared to the oversized group (p = 0.011) and to the size-matched group (p = 0.01). CONCLUSIONS: Oversizing lung allografts more than 10% deteriorated early postoperative outcomes and long-term survival in patients with pulmonary fibrosis.


Subject(s)
Allografts , Lung Transplantation , Pulmonary Fibrosis , Humans , Lung Transplantation/methods , Male , Female , Retrospective Studies , Middle Aged , Pulmonary Fibrosis/surgery , Treatment Outcome , Survival Rate/trends , Follow-Up Studies , Aged , Adult
12.
Eur Heart J Case Rep ; 8(2): ytae035, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38425726

ABSTRACT

Background: The introduction of a transapical transcatheter beating heart replacement system has significantly expanded therapeutic options for patients with severely diseased mitral valves, particularly those ineligibles for traditional surgery or transcatheter repair. However, challenges, such as left ventricular outflow tract obstruction (LVOT-O) and the risk of dynamic systolic anterior motion (SAM) in cases with elongated anterior mitral leaflet (AML) post-prosthesis implantation, impede the widespread adoption of transcatheter mitral valve replacement (TMVR). Case summary: In 2022, a 75-year-old male with severe mixed-genesis mitral regurgitation (MR) underwent Carillon Mitral Contour System annuloplasty. Recurrent heart failure admissions (New York Heart Association IV) and prohibitive risk for open-heart surgery (European System for Cardiac Operative Risk Evaluation II 8.27%) prompted evaluation for Tendyne TMVR with the MitraCut technique. This beating heart transapical approach involved scissor-mediated splitting of the elongated 27 mm AML, essential for mitigating LVOT-O risk and dynamic SAM. The screening echocardiogram revealed the poorly tethered AML near the thickened septum at the simulated neo-LVOT site. Discussion: This case underscores the intricate management challenges associated with severe MR, highlighting the successful application of the MitraCut technique as a viable alternative in high-risk scenarios. The imperative for further research and clinical studies is emphasized to comprehensively elucidate outcomes and safety parameters, providing valuable insights for refining TMVR applications within this context.

13.
Front Cardiovasc Med ; 11: 1344292, 2024.
Article in English | MEDLINE | ID: mdl-38545343

ABSTRACT

Intraluminal thrombus formation (ILT) is a recently discovered and highly clinically relevant complication after frozen elephant trunk implantation in cardiovascular surgery. In this phenomenon, a thrombus forms within the lumen of the stent graft component of the frozen elephant trunk prosthesis and puts the patient at risk for downstream embolization with visceral or lower limb ischemia. Incidence of ILT reported in the currently available studies ranges from 6% to 17% of patients after frozen elephant trunk implantation. Adverse thromboembolic events include acute occlusion of the celiac and superior mesenteric arteries, both renal arteries as well as acute lower limb ischemia due to iliac or femoral artery embolization that not infrequently require interventional or open embolectomy. Therefore, the presence of ILT is associated with increased short-term mortality and morbidity. Currently proposed strategies to avoid ILT formation include a more aggressive anticoagulation management, minimization of postoperative coagulation factor application, and even technical optimizations of the stent graft portion itself. If ILT is manifested, the therapeutic strategies tested to date are long-term escalation of anticoagulation and early endovascular extension of the FET stent graft with overstenting of the intraluminal thrombus. The long-term efficiency of these prophylactic and therapeutic measures has yet to be proven. Nonetheless, all surgeons performing the frozen elephant trunk procedure must be aware of the risk of ILT formation to facilitate a timely diagnosis and therapy.

14.
Diagnostics (Basel) ; 14(5)2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38472937

ABSTRACT

Infective endocarditis (IE) is a severe cardiac complication with high mortality rates, especially when surgical intervention is delayed or absent. This review addresses the expanding role of surgery in managing IE, focusing on the variation in surgical treatment rates, the impact of patient demographics, and the effectiveness of different surgical approaches. Despite varying global data, a notable increase in surgical interventions for IE is evident, with over 50% of patients undergoing surgery in tertiary centres. This review synthesizes information from focused literature searches up to July 2023, covering preoperative to postoperative considerations and surgical strategies for IE. Key preoperative concerns include accurate diagnosis, appropriate antimicrobial treatment, and the timing of surgery, which is particularly crucial for patients with heart failure or at risk of embolism. Surgical approaches vary based on valve involvement, with mitral valve repair showing promising outcomes compared to replacement. Aortic valve surgery, traditionally favouring replacement, now includes repair as a viable option. Emerging techniques such as sutureless valves and aortic homografts are explored, highlighting their potential advantages in specific IE cases. The review also delves into high-risk groups like intravenous drug users and the elderly, emphasizing the need for tailored surgical strategies. With an increasing number of patients presenting with prosthetic valve endocarditis and device-related IE, the review underscores the importance of comprehensive management strategies encompassing surgical and medical interventions. Overall, this review provides a comprehensive overview of current evidence in the surgical management of IE, highlighting the necessity of a multidisciplinary approach and ongoing research to optimize patient outcomes.

15.
J Clin Med ; 13(3)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38337526

ABSTRACT

BACKGROUND: Intercostal artery reinsertion (ICAR) during thoracoabdominal aortic replacement remains controversial. While some groups recommend the reinsertion of as many arteries as possible, others consider the sacrifice of multiple intercostals practicable. This study investigates the impact of intercostal artery reinsertion or sacrifice on neurological outcomes and long-term survival after thoracoabdominal aortic repair. METHODS: A total of 349 consecutive patients undergoing thoracoabdominal aortic replacement at our institution between 1996 and 2021 were analyzed in a retrospective single-center study. ICAR was performed in 213 patients, while all intercostal arteries were ligated and sacrificed in the remaining cases. The neurological outcome was analyzed regarding temporary and permanent paraplegia or paraparesis. RESULTS: No statistically significant differences were observed between the ICAR and non ICAR groups regarding the cumulative endpoint of transient and permanent spinal cord-related complications (12.2% vs. 11.8%, p = 0.9). Operation, bypass, and cross-clamp times were significantly longer in the ICAR group. Likewise, prolonged mechanical ventilation was more often necessary in the ICAR group (26.4% vs. 16.9%, p = 0.03). Overall long-term survival was similar in both groups in the Kaplan-Meier analysis. CONCLUSION: Omitting ICAR during thoracoabdominal aortic replacement may reduce operation and cross-clamp times and thus minimize the duration of intraoperative spinal cord hypoperfusion.

16.
J Mech Behav Biomed Mater ; 152: 106433, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38316085

ABSTRACT

With fibrin-based vascular prostheses, vascular tissue engineering offers a promising approach for the fabrication of biologically active regenerative vascular grafts. As a potentially autologous biomaterial, fibrin exhibits excellent hemo- and biocompatibility. However, the major problem in the use of fibrin constructs in vascular tissue engineering, which has so far prevented their widespread clinical application, is the insufficient biomechanical stability of unprocessed fibrin matrices. In this proof-of-concept study, we investigated to what extent the addition of a spider silk network into the wall structure of fibrin-based vascular prostheses leads to an increase in biomechanical stability and an improvement in the biomimetic elastic behavior of the grafts. For the fabrication of hybrid prostheses composed of fibrin and spider silk, a statically cast tubular fibrin matrix was surrounded with an envelope layer of Trichonephila edulis silk using a custom built coiling machine. The fibrin matrix was then compacted and pressed into the spider silk network by transluminal balloon compression. This manufacturing process resulted in a hybrid prosthesis with a luminal diameter of 4 mm. Biomechanical characterization revealed a significant increase in biomechanical stability of spider silk reinforced grafts compared to exclusively compacted fibrin segments with a mean burst pressure of 362 ± 74 mmHg vs. 213 ± 14 mmHg (p < 0.05). Dynamic elastic behavior of the spider silk reinforced grafts was similar to native arteries. In addition, the coiling with spider silk allowed a significant increase in suture retention strength and resistance to external compression without compromising the endothelialization capacity of the grafts. Thus, spider silk reinforcement using the abluminal coiling technique represents an efficient and reproducible technique to optimize the biomechanical behavior of small-diameter fibrin-based vascular grafts.


Subject(s)
Blood Vessel Prosthesis , Silk , Sutures , Arteries , Fibrin
18.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37506731

ABSTRACT

BACKGROUND: Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations. METHODS: Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta. RESULTS: Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations. CONCLUSION: Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.


Subject(s)
Aortic Rupture , Humans , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Aortic Rupture/surgery , Models, Cardiovascular , Treatment Outcome , Hemodynamics , Computer Simulation , Stents , Stress, Mechanical , Hydrodynamics
19.
Artif Organs ; 48(4): 356-364, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38010063

ABSTRACT

BACKGROUND: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO2) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE. METHODS: Titanium oxide carriers functionalized with copper ions were employed as an antibacterial coating for heart and vascular prostheses. The coating's antibacterial efficacy was assessed using S. aureus ATCC 29213. Microscopic evaluations were conducted on both biological and artificial materials. Antibacterial activity was qualitatively assessed via a modified disc diffusion method and quantitatively measured through colony counts in NaCl suspensions. RESULTS: The coating process was successfully applied to all tested cardiovascular prosthetic materials. Qualitative assessments of antibacterial effectiveness revealed an absence of bacterial growth in the area directly beneath the coated valve. Quantitative evaluations showed a significant reduction in bacterial colonization on coated mechanical valves, with 2.95 × 104 CFU per valve, compared to 1.91 × 105 CFU in control valves. CONCLUSIONS: The 4× Cu-TiO2 coating demonstrated promising antibacterial properties against S. aureus, suggesting its potential as an effective strategy for reducing the risk of bacterial colonization of cardiovascular implants. Further studies are needed to assess the longevity of the coating and its efficacy against other pathogens.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Humans , Copper , Staphylococcus aureus , Pilot Projects , Coated Materials, Biocompatible , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Prostheses and Implants , Endocarditis, Bacterial/prevention & control , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...