Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 71
Filter
1.
Vox Sang ; 2024 May 03.
Article in English | MEDLINE | ID: mdl-38699884

ABSTRACT

BACKGROUND AND OBJECTIVES: West Nile virus (WNV) and Usutu virus (USUV) are mosquito-borne flaviviruses (Flaviviridae) that originated in Africa, have expanded their geographical range during the last decades and caused documented infections in Europe in the last years. Acute WNV and USUV infections have been detected in asymptomatic blood donors by nucleic acid testing. Thus, inactivation of both viral pathogens before blood transfusion is necessary to ensure blood product safety. This study aimed to investigate the efficacy of the THERAFLEX UV-Platelets system to inactivate WNV and USUV in platelet concentrates (PCs). MATERIALS AND METHODS: Plasma-reduced PCs were spiked with the virus suspension. Spiked PC samples were taken after spiking (load and hold sample) and after UVC illumination on the Macotronic UV illumination machine with different light doses (0.05, 0.1, 0.15 and 0.2 (standard) J/cm2). Virus loads of WNV and USUV before and after illumination were measured by titration. RESULTS: Infectivity assays showed that UVC illumination inactivated WNV and USUV in a dose-dependent manner. At a UVC dose of 0.2 J/cm2, the WNV titre was reduced by a log10 factor of 3.59 ± 0.43 for NY99 (lineage 1) and 4.40 ± 0.29 for strain ED-I-33/18 (lineage 2). USUV titres were reduced at the same UVC dose by a log10 factor of 5.20 ± 0.70. CONCLUSIONS: Our results demonstrate that the THERAFLEX UV-Platelets procedure is an effective technology to inactivate WNV and USUV in contaminated PCs.

2.
Transfus Med Hemother ; 51(2): 76-83, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38584696

ABSTRACT

Introduction: Bacterial contamination of blood products presumably occurs mainly during blood collection, starting from low initial concentrations of 10-100 colony-forming units (CFUs) per bag. As little is known about bacterial growth behavior and distribution in stored whole blood (WB) and WB-derived blood products, this study aims to provide data on this subject. Methods: WB units were inoculated with transfusion-relevant bacterial species (Acinetobacter baumannii, Bacillus cereus, Escherichia coli, Klebsiella pneumoniae, Listeria monocytogenes, Pseudomonas fluorescens, Serratia marcescens, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus dysgalactiae, Streptococcus pyogenes, Yersinia enterocolitica; n = 12 for each species), stored for 22-24 h at room temperature, and then centrifuged for separation into plasma, red blood cells (RBCs), and buffy coats (BCs). The latter were pooled with 3 random donor BCs and one unit of PAS-E each to yield plasma-reduced platelet concentrates (PCs). Samples for bacterial colony counting were collected after WB storage and immediately after blood component production. Sterility testing in PCs (n = 12 for each species) was performed by bacterial culture after 7 days of storage. Results: Bacterial growth in WB varied remarkably between donations and species. Streptococcus species produced the highest titers in WB, whereas Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Pseudomonas fluorescens did not multiply. Centrifugation resulted in preferential accumulation of bacteria in BCs, with titers of up to 3.5 × 103 CFU/mL in BCs and up to ≤0.9 × 103 CFU/mL in BC-derived PCs. Overall, 72/144 PCs (50%) tested positive for bacteria after storage. Sterility test results were species-dependent, ranging from 12 of 12 PCs tested positive for Streptococcus pyogenes to 1 of 12 PCs positive for Escherichia coli. Bacterial contamination of RBC and plasma units was much less common and was associated with higher initial bacterial counts in the parent WB units. Conclusions: Bacterial growth in WB is species-dependent and varies greatly between donations. Preferential accumulation of bacteria in BCs during manufacturing is a critical determinant of the contamination risk of BC-derived pooled PCs.

3.
Vox Sang ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38631895

ABSTRACT

BACKGROUND AND OBJECTIVES: Platelet concentrates (PC) are stored at 20-24°C to maintain platelet functionality, which may promote growth of contaminant bacteria. Alternatively, cold storage of PC limits bacterial growth; however, data related to proliferation of psychotrophic species in cold-stored PC (CSP) are scarce, which is addressed in this study. MATERIALS AND METHODS: Eight laboratories participated in this study with a pool/split approach. Two split PC units were spiked with ~25 colony forming units (CFU)/PC of Staphylococcus aureus, Klebsiella pneumoniae, Serratia liquefaciens, Pseudomonas fluorescens and Listeria monocytogenes. One unit was stored under agitation at 20-24°C/7 days while the second was stored at 1-6°C/no agitation for 21 days. PC were sampled periodically to determine bacterial loads. Five laboratories repeated the study with PC inoculated with lyophilized inocula (~30 CFU/mL) of S. aureus and K. pneumoniae. RESULTS: All species proliferated in PC stored at 20-24°C, reaching concentrations of ≤109 CFU/mL by day 7. Psychrotrophic P. fluorescens and S. liquefaciens proliferated in CSP to ~106 CFU/mL and ~105 CFU/mL on days 10 and 17 of storage, respectively, followed by L. monocytogenes, which reached ~102 CFU/mL on day 21. S. aureus and K. pneumoniae did not grow in CSP. CONCLUSION: Psychrotrophic bacteria, which are relatively rare contaminants in PC, proliferated in CSP, with P. fluorescens reaching clinically significant levels (≥105 CFU/mL) before day 14 of storage. Cold storage reduces bacterial risk of PC to levels comparable with RBC units. Safety of CSP could be further improved by implementing bacterial detection systems or pathogen reduction technologies if storage is beyond 10 days.

4.
Transfusion ; 64 Suppl 2: S27-S33, 2024 May.
Article in English | MEDLINE | ID: mdl-38251751

ABSTRACT

BACKGROUND: Whole blood (WB) collections can occur downrange for immediate administration. An important aspect of these collections is determining when the unit is sufficiently full. This project tested a novel method for determining when a field collection is complete. METHODS: The amount of empty space at the top of WB units, destined to become LTOWB or separated into components, that were collected at blood centers or hospitals was measured by holding a WB unit off the ground and placing the top of a piece of string where the donor tubing entered the bag. The string was marked where it intersected the top of the column of blood in the bag and measured from the top. The WB units were also weighed. RESULTS: A total of 15 different bags, two of which were measured in two different filling volumes, from 15 hospitals or blood centers were measured and weighed. The most commonly used blood bag, Terumo Imuflex SP, had a median string length of 9 mm (range: 2-24 mm) and weighed a median of 565.1 g (range: 524.8-636.7 g). CONCLUSION: Pieces of string can be precut to the appropriate length depending on the type of bag before a mission where field WB collections might be required and a mark placed on the bag before the collection commences to indicate when the unit is full.


Subject(s)
Blood Donors , Humans , Blood Banks , Blood Specimen Collection/methods , Blood Specimen Collection/instrumentation
5.
Vox Sang ; 118(7): 559-566, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37218336

ABSTRACT

BACKGROUND AND OBJECTIVES: Large clinical trials have demonstrated that some patient groups with hypoproliferative thrombocytopenia benefit from prophylactic platelet transfusions, while in others, a therapeutic transfusion regimen might be sufficient. The remaining capacity to generate endogenous platelets might be helpful to select the platelet transfusion regimen. We assessed whether the recently described method of digital droplet polymerase chain reaction (PCR) can be used to assess the endogenous platelet levels in two groups of patients undergoing high-dose chemotherapy with autologous stem cell transplantation (ASCT). MATERIALS AND METHODS: Multiple myeloma (n = 22) patients received high-dose melphalan alone (HDMA); lymphoma patients (n = 15) received BEAM or TEAM (B/TEAM) conditioning. Patients with a total platelet count <10 G/L received prophylactic apheresis platelet concentrates. Daily endogenous platelet counts were measured by digital droplet PCR for at least 10 days post-ASCT. RESULTS: Post-transplantation B/TEAM patients received their first platelet transfusion on average 3 days earlier than HDMA patients (p < 0.001) and required about twofold more platelet concentrates (p < 0.001). The endogenous platelet count fell ≤5 G/L for a median of 115 h (91-159; 95% confidence interval) in B/TEAM-treated patients compared to 12.6 h (0-24) (p < 0.0001) in HDMA-treated patients. Multivariate analysis confirmed this profound effect of the high-dose regimen (p < 0.001). The CD-34+ -cell dose in the graft was inversely correlated with the intensity of endogenous thrombocytopenia in B/TEAM-treated patients. CONCLUSION: Monitoring endogenous platelet counts detects the direct effects of myelosuppressive chemotherapies on platelet regeneration. This approach may help to develop a platelet transfusion regimen tailored to specific patient groups.


Subject(s)
Hematopoietic Stem Cell Transplantation , Thrombocytopenia , Humans , Hematopoietic Stem Cell Transplantation/adverse effects , Blood Platelets , Transplantation, Autologous , Thrombocytopenia/etiology , Thrombocytopenia/therapy , Platelet Transfusion/adverse effects
6.
Transfusion ; 63(2): 288-293, 2023 02.
Article in English | MEDLINE | ID: mdl-36573801

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is unlikely to be a major transfusion-transmitted pathogen; however, convalescent plasma is a treatment option used in some regions. The risk of transfusion-transmitted infections can be minimized by implementing Pathogen Inactivation (PI), such as THERAFLEX MB-plasma and THERAFLEX UV-Platelets systems. Here we examined the capability of these PI systems to inactivate SARS-CoV-2. STUDY DESIGN AND METHODS: SARS-CoV-2 spiked plasma units were treated using the THERAFLEX MB-Plasma system in the presence of methylene blue (~0.8 µmol/L; visible light doses: 20, 40, 60, and 120 [standard] J/cm2 ). SARS-CoV-2 spiked platelet concentrates (PCs) were treated using the THERAFLEX UV-platelets system (UVC doses: 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2 ). Samples were taken prior to the first and after each illumination dose, and viral infectivity was assessed using an immunoplaque assay. RESULTS: Treatment of spiked plasma with the THERAFLEX MB-Plasma system resulted in an average ≥5.03 log10 reduction in SARS-CoV-2 infectivity at one third (40 J/cm2 ) of the standard visible light dose. For the platelet concentrates (PCs), treatment with the THERAFLEX UV-Platelets system resulted in an average ≥5.18 log10 reduction in SARS-CoV-2 infectivity at the standard UVC dose (0.2 J/cm2 ). CONCLUSIONS: SARS-CoV-2 infectivity was reduced in plasma and platelets following treatment with the THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems, to the limit of detection, respectively. These PI technologies could therefore be an effective option to reduce the risk of transfusion-transmitted emerging pathogens.


Subject(s)
COVID-19 , Methylene Blue , Humans , Methylene Blue/pharmacology , SARS-CoV-2 , COVID-19/therapy , COVID-19 Serotherapy , Light , Ultraviolet Rays , Blood Platelets , Virus Inactivation
7.
Transfusion ; 62(11): 2314-2323, 2022 11.
Article in English | MEDLINE | ID: mdl-36087025

ABSTRACT

BACKGROUND: Pathogen inactivation (PI) technologies for platelet concentrates and plasma are steadily becoming more established, but new PI treatment options for red blood cells (RBCs), the most commonly used blood component, still need to be developed. We present a novel approach to inactivating pathogens in RBC units employing ultraviolet C (UVC) light. METHODS: Whole blood-derived leukoreduced RBCs suspended in PAGGS-C, a third generation additive solution, served as test samples, and RBCs in PAGGS-C or SAG-M as controls. Vigorous agitation and hematocrit reduction by diluting the RBCs with additional additive solution during illumination ensured that UVC light penetrated and inactivated the nine bacteria and eight virus species tested. Bacterial and viral infectivity assays and in vitro analyses were performed to evaluate the system's PI capacity and to measure the RBC quality, metabolic, functional, and blood group serological parameters of UVC-treated versus untreated RBCs during 36-day storage. RESULTS: UVC treatment of RBCs in the PAGGS-C additive solution did not alter RBC antigen expression, but significantly influenced some in vitro parameters. Compared to controls, hemolysis was higher in UVC-treated RBC units, but was still below 0.8% at 36 days of storage. Extracellular potassium increased early after PI treatment and reached ≤70 mmol/L by the end of storage. UVC-treated RBC units had higher glucose and 2,3-diphosphoglycerate levels than controls. CONCLUSION: As UVC irradiation efficiently reduces the infectivity of relevant bacteria and viruses while maintaining the quality of RBCs, the proposed method offers a new approach for PI of RBC concentrates.


Subject(s)
Blood Preservation , Erythrocytes , Humans , Blood Preservation/methods , Erythrocytes/metabolism , Hemolysis , Ultraviolet Rays , Erythrocyte Count
8.
Haematologica ; 106(4): 1086-1096, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33538149

ABSTRACT

Pathogen reduction (PR) technologies for blood components have been established to reduce the residual risk of known and emerging infectious agents. THERAFLEX UVPlatelets, a novel UVC light-based PR technology for platelet concentrates, works without photoactive substances. This randomized, controlled, double-blind, multicenter, noninferiority trial was designed to compare the efficacy and safety of UVC-treated platelets to that of untreated platelets in thrombocytopenic patients with hematologic-oncologic diseases. Primary objective was to determine non-inferiority of UVC-treated platelets, assessed by the 1-hour corrected count increment (CCI) in up to eight per-protocol platelet transfusion episodes. Analysis of the 171 eligible patients showed that the defined non-inferiority margin of 30% of UVC-treated platelets was narrowly missed as the mean differences in 1-hour CCI between standard platelets versus UVC-treated platelets for intention-to-treat and perprotocol analyses were 18.2% (95% confidence interval [CI]: 6.4%; 30.1) and 18.7% (95% CI: 6.3%; 31.1%), respectively. In comparison to the control, the UVC group had a 19.2% lower mean 24-hour CCI and was treated with an about 25% higher number of platelet units, but the average number of days to next platelet transfusion did not differ significantly between both treatment groups. The frequency of low-grade adverse events was slightly higher in the UVC group and the frequencies of refractoriness to platelet transfusion, platelet alloimmunization, severe bleeding events, and red blood cell transfusions were comparable between groups. Our study suggests that transfusion of pathogen-reduced platelets produced with the UVC technology is safe but non-inferiority was not demonstrated. (The German Clinical Trials Register number: DRKS00011156).


Subject(s)
Hematologic Diseases , Thrombocytopenia , Blood Platelets , Hemorrhage , Humans , Platelet Transfusion , Thrombocytopenia/etiology , Thrombocytopenia/therapy
9.
Materials (Basel) ; 13(15)2020 Jul 31.
Article in English | MEDLINE | ID: mdl-32752065

ABSTRACT

The development of alloplastic resorbable materials can revolutionize the field of implantation technology in regenerative medicine. Additional opportunities to colonize the three-dimensionally (3D) printed constructs with the patient's own cells prior to implantation can improve the regeneration process but requires optimization of cultivation protocols. Human platelet lysate (hPL) has already proven to be a suitable replacement for fetal calf serum (FCS) in 2D and 3D cell cultures. In this study, we investigated the in vitro biocompatibility of the printed RESOMER® Filament LG D1.75 materials as well as the osteogenic differentiation of human mesenchymal stem cells (hMSCs) cultivated on 3D printed constructs under the influence of different medium supplements (FCS, human serum (HS) and hPL). Additionally, the in vitro degradation of the material was studied over six months. We demonstrated that LG D1.75 is biocompatible and has no in vitro cytotoxic effects on hMSCs. Furthermore, hMSCs grown on the constructs could be differentiated into osteoblasts, especially supported by supplementation with hPL. Over six months under physiological in vitro conditions, a distinct degradation was observed, which, however, had no influence on the biocompatibility of the material. Thus, the overall suitability of the material LG D1.75 to produce 3D printed, resorbable bone implants and the promising use of hPL in the xeno-free cultivation of human MSCs on such implants for autologous transplantation have been demonstrated.

10.
Transfusion ; 60(11): 2655-2660, 2020 11.
Article in English | MEDLINE | ID: mdl-32830340

ABSTRACT

Japanese encephalitis virus (JEV) is endemic to tropical areas in Asia and the Western Pacific. It can cause fatal encephalitis, although most infected individuals are asymptomatic. JEV is mainly transmitted to humans through the bite of an infected mosquito, but can also be transmitted through blood transfusion. To manage the potential risk of transfusion transmission, pathogen inactivation (PI) technologies, such as THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems, have been developed. We examined the efficacy of these two PI systems to inactivate JEV. STUDY DESIGN AND METHODS: Japanese encephalitis virus-spiked plasma units were treated using the THERAFLEX MB-Plasma system (visible light doses, 20, 40, 60, and 120 [standard] J/cm2) in the presence of methylene blue at approximately 0.8 µmol/L and spiked platelet concentrates (PCs) were treated using the THERAFLEX UV-Platelets system (UVC doses, 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2). Samples were taken before the first and after each illumination dose and tested for infectivity using an immunoplaque assay. RESULTS: Treatment of plasma with the THERAFLEX MB-Plasma system resulted in an average of 6.59 log reduction in JEV infectivity at one-sixth of the standard visible light dose (20 J/cm2). For PCs, treatment with the THERAFLEX UV-Platelet system resulted in an average of 7.02 log reduction in JEV infectivity at the standard UVC dose (0.20 J/cm2). CONCLUSIONS: The THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems effectively inactivated JEV in plasma or PCs, and thus these PI technologies could be an effective option to reduce the risk of JEV transfusion transmission.


Subject(s)
Encephalitis Virus, Japanese/growth & development , Light , Methylene Blue/pharmacology , Plasma/virology , Virus Inactivation , Humans , Virus Inactivation/drug effects , Virus Inactivation/radiation effects
11.
Nat Commun ; 11(1): 3569, 2020 07 16.
Article in English | MEDLINE | ID: mdl-32678083

ABSTRACT

The clinically important MAM blood group antigen is present on haematopoietic cells of all humans except rare MAM-negative individuals. Its molecular basis is unknown. By whole-exome sequencing we identify EMP3, encoding epithelial membrane protein 3 (EMP3), as a candidate gene, then demonstrate inactivating mutations in ten known MAM-negative individuals. We show that EMP3, a purported tumour suppressor in various solid tumours, is expressed in erythroid cells. Disruption of EMP3 by CRISPR/Cas9 gene editing in an immortalised human erythroid cell line (BEL-A2) abolishes MAM expression. We find EMP3 to associate with, and stabilise, CD44 in the plasma membrane. Furthermore, cultured erythroid progenitor cells from MAM-negative individuals show markedly increased proliferation and higher reticulocyte yields, suggesting an important regulatory role for EMP3 in erythropoiesis and control of cell production. Our data establish MAM as a new blood group system and demonstrate an interaction of EMP3 with the cell surface signalling molecule CD44.


Subject(s)
Blood Group Antigens/genetics , Cell Proliferation , Erythroid Cells/cytology , Membrane Glycoproteins/genetics , Blood Group Antigens/chemistry , Blood Group Antigens/metabolism , Blood Platelets/metabolism , Cells, Cultured , Erythrocyte Membrane/metabolism , Erythroid Cells/metabolism , Humans , Hyaluronan Receptors/metabolism , Membrane Glycoproteins/chemistry , Membrane Glycoproteins/metabolism , Models, Molecular , Mutation , Phenotype , Protein Binding , Exome Sequencing
12.
Transfusion ; 60(8): 1821-1827, 2020 08.
Article in English | MEDLINE | ID: mdl-32537745

ABSTRACT

BACKGROUND: UVC illumination of agitated platelet concentrates (PCs) inactivates pathogens and white blood cells by modifications of their nucleic acids. Related effects on mitochondrial DNA (mtDNA) in platelets serve as a basis for an efficient monitoring suited for routine quality control (QC) of this purely physical pathogen reduction technology. STUDY DESIGN AND METHODS: Samples from PCs (n = 530) were tested with an established LightCycler PCR (LC PCR) for QC of the UVC procedure. RNR2 and TRNK/ATP8 genes were sequenced in the PCs (n = 21) with out-of-specification results in the LC PCR. A digital droplet PCR (ddPCR) was developed to minimize the outliers and cross-validated by testing the 530 PCs. The ddPCR was further evaluated in a subgroup of 300 PCs without mtDNA extraction and in samples from systematic variations of UVC dose and agitation speed. RESULTS: Apheresis PCs (n = 380) resulted in 5.3% outliers in LC PCR versus only 0.7% in buffy coat pool PCs (n = 150). Sequencing of these outliers revealed single-nucleotide polymorphisms in the primer- and probe-binding sites of LC PCR. The development of a ddPCR assay with modified probe sequences reduced the outliers to 0.4%. The ddPCR analysis of PCs both with and without mtDNA extraction demonstrated low intra- and interassay variabilities and congruent results also compared to LC PCR. Experiments varying the UVC dose and the agitation speed demonstrated that the ddPCR results closely reflect functional effects of the UVC treatment. CONCLUSION: The ddPCR assay offers a valid and reliable tool for QC of routine production of the UVC-treated PCs as well as for monitoring treatment conditions during optimization of the UVC procedure.


Subject(s)
Blood Buffy Coat , Blood Platelets , DNA, Mitochondrial/genetics , Mitochondrial Proteins/genetics , Polymerase Chain Reaction , Polymorphism, Single Nucleotide , Ultraviolet Rays , Humans , Plateletpheresis , Quality Control
13.
Vox Sang ; 115(7): 555-561, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32383163

ABSTRACT

BACKGROUND AND OBJECTIVES: As previous investigations have shown, THERAFLEX UV-Platelets, a UVC-based pathogen inactivation (PI) system, is effective against non-enveloped transfusion-relevant viruses such as hepatitis A virus (HAV), which are insensitive to most PI treatments for blood products. This study investigated the PI efficacy of THERAFLEX UV-Platelets against HEV in platelet concentrates (PCs). MATERIALS AND METHODS: Buffy coat-derived PCs in additive solution were spiked with cell culture-derived HEV and treated with the THERAFLEX UV-Platelets system using various doses of UVC (0·05, 0·10, 0·15 and 0·20 (standard) J/cm2 ). Titres of infectious virus in pre- and post-treatment samples were determined using a large-volume plating assay to improve the detection limit of the virus assay. RESULTS: THERAFLEX UV-Platelets dose-dependently inactivated HEV in PCs. The standard UVC dose inactivated the virus to below the limit of detection, corresponding to a mean log reduction of greater than 3·5. CONCLUSION: Our study demonstrates that the THERAFLEX UV-Platelets system effectively inactivates HEV in PCs.


Subject(s)
Blood Platelets/virology , Blood Safety/methods , Hepatitis E virus/radiation effects , Ultraviolet Rays , Humans
14.
Transfusion ; 60(3): 544-552, 2020 03.
Article in English | MEDLINE | ID: mdl-32034925

ABSTRACT

BACKGROUND: Determination of blood donor hemoglobin (Hb) levels is a pre-requisite to ensure donor safety and blood product quality. We aimed to identify Hb measurement practices across blood donation services and to what extent differences associate with low-Hb deferral rates. METHODS: An online survey was performed among Biomedical Excellence for Safer Transfusion (BEST) Collaborative members, extended with published data. Multivariable negative-binomial regression models were built to estimate adjusted associations of minimum donation intervals, Hb cut-offs (high, ≥13.5 g/dL in men or ≥ 12.5 g/dL in women, vs. lower values), iron monitoring (yes/no), providing or prescribing iron supplementation (yes/no), post-versus pre-donation Hb measurement and geographical location (Asian vs. rest), with low-Hb deferral rates. RESULTS: Data were included from 38 blood services. Low-Hb deferral rates varied from 0.11% to 8.81% among men and 0.84% to 31.85% among women. Services with longer minimum donation intervals had significantly lower deferral rates among both women (rate ratio, RR 0.53, 95%CI 0.33-0.84) and men (RR 0.53, 95%CI 0.31-0.90). In women, iron supplementation was associated with lower Hb deferral rates (RR 0.47, 95%CI 0.23-0.94). Finally, being located in Asia was associated with higher low-Hb deferral rates; RR 9.10 (95%CI 3.89-21.27) for women and 6.76 (95%CI 2.45-18.68) for men. CONCLUSION: Differences in Hb measurement and eligibility criteria, particularly longer donation intervals and iron supplementation in women, are associated with variations in low-Hb deferral rates. These insights could help improve both blood donation service efficiency and donor care.


Subject(s)
Blood Donors/statistics & numerical data , Hemoglobins/metabolism , Blood Transfusion/methods , Donor Selection , Female , Hematologic Tests , Humans , Iron/metabolism , Surveys and Questionnaires , Time Factors
15.
Vox Sang ; 115(3): 146-151, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31930543

ABSTRACT

BACKGROUND: Emerging viruses like severe acute respiratory syndrome coronavirus (SARS-CoV), Crimean-Congo haemorrhagic fever virus (CCHFV) and Nipah virus (NiV) have been identified to pose a potential threat to transfusion safety. In this study, the ability of the THERAFLEX UV-Platelets and THERAFLEX MB-Plasma pathogen inactivation systems to inactivate these viruses in platelet concentrates and plasma, respectively, was investigated. MATERIALS AND METHODS: Blood products were spiked with SARS-CoV, CCHFV or NiV, and then treated with increasing doses of UVC light (THERAFLEX UV-Platelets) or with methylene blue (MB) plus increasing doses of visible light (MB/light; THERAFLEX MB-Plasma). Samples were taken before and after treatment with each illumination dose and tested for residual infectivity. RESULTS: Treatment with half to three-fourths of the full UVC dose (0·2 J/cm2 ) reduced the infectivity of SARS-CoV (≥3·4 log), CCHFV (≥2·2 log) and NiV (≥4·3 log) to the limit of detection (LOD) in platelet concentrates, and treatment with MB and a fourth of the full light dose (120 J/cm2 ) decreased that of SARS-CoV (≥3·1 log), CCHFV (≥3·2 log) and NiV (≥2·7 log) to the LOD in plasma. CONCLUSION: Our study demonstrates that both THERAFLEX UV-Platelets (UVC) and THERAFLEX MB-Plasma (MB/light) effectively reduce the infectivity of SARS-CoV, CCHFV and NiV in platelet concentrates and plasma, respectively.


Subject(s)
Hemorrhagic Fever Virus, Crimean-Congo/radiation effects , Light , Methylene Blue/pharmacology , Nipah Virus/radiation effects , Severe acute respiratory syndrome-related coronavirus/radiation effects , Ultraviolet Rays , Virus Inactivation , Blood Platelets/virology , Blood Transfusion , Hemorrhagic Fever Virus, Crimean-Congo/drug effects , Humans , Nipah Virus/drug effects , Plasma/virology , Severe acute respiratory syndrome-related coronavirus/drug effects
16.
Front Bioeng Biotechnol ; 8: 598389, 2020.
Article in English | MEDLINE | ID: mdl-33520956

ABSTRACT

In vitro two-dimensional (2D) and three-dimensional (3D) cultivation of mammalian cells requires supplementation with serum. Mesenchymal stem cells (MSCs) are widely used in clinical trials for bioregenerative medicine and in most cases, in vitro expansion and differentiation of these cells are required before application. Optimized expansion and differentiation protocols play a key role in the treatment outcome. 3D cell cultivation systems are more comparable to in vivo conditions and can provide both, more physiological MSC expansion and a better understanding of intercellular and cell-matrix interactions. Xeno-free cultivation conditions minimize risks of immune response after implantation. Human platelet lysate (hPL) appears to be a valuable alternative to widely used fetal calf serum (FCS) since no ethical issues are associated with its harvest, it contains a high concentration of growth factors and cytokines and it can be produced from expired platelet concentrate. In this study, we analyzed and compared proliferation, as well as osteogenic and chondrogenic differentiation of human adipose tissue-derived MSCs (hAD-MSC) using three different supplements: FCS, human serum (HS), and hPL in 2D. Furthermore, online monitoring of osteogenic differentiation under the influence of different supplements was performed in 2D. hPL-cultivated MSCs exhibited a higher proliferation and differentiation rate compared to HS- or FCS-cultivated cells. We demonstrated a fast and successful chondrogenic differentiation in the 2D system with the addition of hPL. Additionally, FCS, HS, and hPL were used to formulate Gelatin-methacryloyl (GelMA) hydrogels in order to evaluate the influence of the different supplements on the cell spreading and proliferation of cells growing in 3D culture. In addition, the hydrogel constructs were cultivated in media supplemented with three different supplements. In comparison to FCS and HS, the addition of hPL to GelMA hydrogels during the encapsulation of hAD-MSCs resulted in enhanced cell spreading and proliferation. This effect was promoted even further by cultivating the hydrogel constructs in hPL-supplemented media.

17.
Vox Sang ; 114(8): 783-794, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31637738

ABSTRACT

INTRODUCTION: In vitro qualitative differences exist in red cell concentrates (RCCs) units processed from whole blood (WB) depending on the method of processing. Minimal literature exists on differences in processing and variability in quality data. Therefore, we collected information from blood manufacturers worldwide regarding (1) details of WB collection and processing used to produce RCCs and (2) quality parameters and testing as part of routine quality programmes. METHODS: A secure web-based survey was developed, refined after pilot data collection and distributed to blood centres. Descriptive analyses were performed. RESULTS: Data from ten blood centres in nine countries were collected. Six blood centres (60%) processed RCCs using the top-and-top (TAT) method which produces RCCs and plasma, and eight centres (80%) used the bottom-and-top (BAT) which additionally produces buffy coat platelets. Five of the centres used both processing methods; however, four favoured BAT processing. One centre utilized the Reveos automated system exclusively. All centres performed pre-storage leucoreduction. Other parameters demonstrated variability, including active cooling at collection, length of hold before processing, donor haemoglobin limits, acceptable collection weights, collection sets, time to leucoreduction, centrifugation speeds, extraction devices and maximum RCC shelf life. Quality marker testing also differed amongst blood centres. Trends towards higher RCC unit volume, haemolysis and residual leucoctyes were seen in the TAT compared with BAT processing across centres. CONCLUSION: Methods and parameters of WB processing and quality testing of RCCs differ amongst surveyed blood manufacturers. Further studies are needed to assess variations and to potentially improve methods and product quality.


Subject(s)
Blood Banks/standards , Blood Preservation/standards , Erythrocytes/cytology , Blood Preservation/methods , Humans , Surveys and Questionnaires , Blood Banking/methods
18.
Bioengineering (Basel) ; 6(3)2019 Aug 28.
Article in English | MEDLINE | ID: mdl-31466260

ABSTRACT

Three-dimensional (3D) cell culture is a major focus of current research, since cultivation under physiological conditions provides more reliable information about in vivo cell behavior. 3D cell cultures are used in basic research to better understand intercellular and cell-matrix interactions. However, 3D cell culture plays an increasingly important role in the in vitro testing of bioactive substances and tissue engineering. Gelatin-methacryloyl (GelMA) hydrogels of different degrees of functionalization (DoFs) are a versatile tool for 3D cell culture and related applications such as bioprinting. Human platelet lysate (hPL) has already demonstrated positive effects on 2D cell cultures of different cell types and has proven a valuable alternative to fetal calf serum (FCS). Traditionally, all hydrogels are formulated using buffers. In this study, we supplemented GelMA hydrogels of different DoF with hPL during adipose tissue-derived mesenchymal stem cell (AD-MSCs) encapsulation. We studied the effect of hPL supplementation on the spreading, proliferation, and osteogenic differentiation of AD-MSCs. In addition, the influence of hPL on hydrogel properties was also investigated. We demonstrate that the addition of hPL enhanced AD-MSC spreading, proliferation, and osteogenic differentiation in a concentration-dependent manner. Moreover, the addition of hPL also increased GelMA viscosity and stiffness.

19.
Transfusion ; 59(7): 2223-2227, 2019 07.
Article in English | MEDLINE | ID: mdl-31050821

ABSTRACT

BACKGROUND: Yellow fever virus (YFV) is endemic to tropical and subtropical areas in South America and Africa, and is currently a major public health threat in Brazil. Transfusion transmission of the yellow fever vaccine virus has been demonstrated, which is indicative of the potential for viral transfusion transmission. An approach to manage the potential YFV transfusion transmission risk is the use of pathogen inactivation (PI) technology systems, such as THERAFLEX MB-Plasma and THERAFLEX UV-Platelets (Macopharma). We aimed to investigate the efficacy of these PI technology systems to inactivate YFV in plasma or platelet concentrates (PCs). STUDY DESIGN AND METHODS: YFV spiked plasma units were treated using THERAFLEX MB-Plasma system (visible light doses: 20, 40, 60, and 120 [standard] J/cm2 ) in the presence of methylene blue (approx. 0.8 µmol/L) and spiked PCs were treated using THERAFLEX UV-Platelets system (ultraviolet C doses: 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2 ). Samples were taken before the first and after each illumination dose and tested for residual virus using a modified plaque assay. RESULTS: YFV infectivity was reduced by an average of 4.77 log or greater in plasma treated with the THERAFLEX MB-Plasma system and by 4.8 log or greater in PCs treated with THERAFLEX UV-Platelets system. CONCLUSIONS: Our study suggests the THERAFLEX MB-Plasma and the THERAFLEX UV-Platelets systems can efficiently inactivate YFV in plasma or PCs to a similar degree as that for other arboviruses. Given the reduction levels observed in this study, these PI technology systems could be an effective option for managing YFV transfusion-transmission risk in plasma and PCs.


Subject(s)
Blood Platelets/virology , Light , Methylene Blue/pharmacology , Plasma/virology , Ultraviolet Rays , Yellow fever virus/drug effects , Africa , Animals , Blood Banking/methods , Blood Transfusion , Chlorocebus aethiops , Disease Transmission, Infectious/prevention & control , Humans , South America , Vero Cells , Yellow Fever/transmission , Yellow fever virus/radiation effects
20.
Transfusion ; 59(4): 1324-1332, 2019 04.
Article in English | MEDLINE | ID: mdl-30588633

ABSTRACT

BACKGROUND: The THERAFLEX UV-Platelets system (Maco Pharma) uses ultraviolet C (UVC) light for pathogen inactivation (PI) of platelet concentrates (PCs) without any additional photoactive compound. The aim of the study was to systematically investigate bacterial inactivation with this system under conditions of intended use. STUDY DESIGN AND METHODS: The robustness of the system was evaluated by assessing its capacity to inactivate high concentrations of different bacterial species in accordance with World Health Organization guidelines. The optimal use of the PI system was explored in time-to-treatment experiments by testing its ability to sterilize PCs contaminated with low levels of bacteria on the day of manufacture (target concentration, 100 colony-forming units/unit). The bacteria panel used for spiking experiments in this study included the World Health Organization International Repository Platelet Transfusion Relevant Reference Strains (n = 14), commercially available strains (n = 13), and in-house clinical isolates (n = 2). RESULTS: Mean log reduction factors after UVC treatment ranged from 3.1 to 7.5 and varied between different strains of the same species. All PCs (n = 12/species) spiked with up to 200 colony-forming units/bag remained sterile until the end of storage when UVC treated 6 hours after spiking. UVC treatment 8 hours after spiking resulted in single breakthrough contaminations with the fast-growing species Escherichia coli and Streptococcus pyogenes. CONCLUSION: The UVC-based THERAFLEX UV-Platelets system efficiently inactivates transfusion-relevant bacterial species in PCs. The comprehensive data from this study may provide a valuable basis for the optimal use of this UVC-based PI system.


Subject(s)
Bacteria/radiation effects , Blood Platelets/microbiology , Platelet Transfusion/methods , Sterilization/methods , Ultraviolet Rays , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...