Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 68
Filter
1.
Health Justice ; 12(1): 36, 2024 Aug 29.
Article in English | MEDLINE | ID: mdl-39207608

ABSTRACT

At the intersection of drug policy, the opioid crisis, and fragmented care systems, persons with opioid use disorder (OUD) in the United States are significantly vulnerable to contact with the criminal legal system (CLS). In CLS settings, provision of evidence-based treatment for OUD is variable and often secondary to punitive approaches. Linkage facilitation at every touch point along the CLS Sequential Intercept Model has potential to redirect persons with OUD into recovery-oriented systems of care, increase evidence-based OUD treatment connections, and therefore reduce CLS re-exposure risk. Research in this area is still nascent. Thus, this narrative review explores the state of the science on linkage facilitation across the varied CLS contexts, including general barriers, facilitators, and opportunities for using linkage facilitation for OUD treatment and related services. Following the CLS Sequential Intercept Model, the specific CLS contexts examined include community services, police encounters, the courts (pre- and post-disposition), incarceration (pre-trial detention, jail, and prison), reentry (from jails, prisons, and unified systems), and community supervision (probation and parole). Examples of innovative linkage facilitation interventions are drawn from the Justice Community Opioid Innovation Network (JCOIN). Areas for future research and policy change are highlighted to advance the science of linkage facilitation for OUD services in the CLS.

2.
Lancet Microbe ; 5(6): e559-e569, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38815595

ABSTRACT

BACKGROUND: Serial measurement of virological and immunological biomarkers in patients admitted to hospital with COVID-19 can give valuable insight into the pathogenic roles of viral replication and immune dysregulation. We aimed to characterise biomarker trajectories and their associations with clinical outcomes. METHODS: In this international, prospective cohort study, patients admitted to hospital with COVID-19 and enrolled in the Therapeutics for Inpatients with COVID-19 platform trial within the Accelerating COVID-19 Therapeutic Interventions and Vaccines programme between Aug 5, 2020 and Sept 30, 2021 were included. Participants were included from 108 sites in Denmark, Greece, Poland, Singapore, Spain, Switzerland, Uganda, the UK, and the USA, and randomised to placebo or one of four neutralising monoclonal antibodies: bamlanivimab (Aug 5 to Oct 13, 2020), sotrovimab (Dec 16, 2020, to March 1, 2021), amubarvimab-romlusevimab (Dec 16, 2020, to March 1, 2021), and tixagevimab-cilgavimab (Feb 10 to Sept 30, 2021). This trial included an analysis of 2149 participants with plasma nucleocapsid antigen, anti-nucleocapsid antibody, C-reactive protein (CRP), IL-6, and D-dimer measured at baseline and day 1, day 3, and day 5 of enrolment. Day-90 follow-up status was available for 1790 participants. Biomarker trajectories were evaluated for associations with baseline characteristics, a 7-day pulmonary ordinal outcome, 90-day mortality, and 90-day rate of sustained recovery. FINDINGS: The study included 2149 participants. Participant median age was 57 years (IQR 46-68), 1246 (58·0%) of 2149 participants were male and 903 (42·0%) were female; 1792 (83·4%) had at least one comorbidity, and 1764 (82·1%) were unvaccinated. Mortality to day 90 was 172 (8·0%) of 2149 and 189 (8·8%) participants had sustained recovery. A pattern of less favourable trajectories of low anti-nucleocapsid antibody, high plasma nucleocapsid antigen, and high inflammatory markers over the first 5 days was observed for high-risk baseline clinical characteristics or factors related to SARS-CoV-2 infection. For example, participants with chronic kidney disease demonstrated plasma nucleocapsid antigen 424% higher (95% CI 319-559), CRP 174% higher (150-202), IL-6 173% higher (144-208), D-dimer 149% higher (134-165), and anti-nucleocapsid antibody 39% lower (60-18) to day 5 than those without chronic kidney disease. Participants in the highest quartile for plasma nucleocapsid antigen, CRP, and IL-6 at baseline and day 5 had worse clinical outcomes, including 90-day all-cause mortality (plasma nucleocapsid antigen hazard ratio (HR) 4·50 (95% CI 3·29-6·15), CRP HR 3·37 (2·30-4·94), and IL-6 HR 5·67 (4·12-7·80). This risk persisted for plasma nucleocapsid antigen and CRP after adjustment for baseline biomarker values and other baseline factors. INTERPRETATION: Patients admitted to hospital with less favourable 5-day biomarker trajectories had worse prognosis, suggesting that persistent viral burden might drive inflammation in the pathogenesis of COVID-19, identifying patients that might benefit from escalation of antiviral or anti-inflammatory treatment. FUNDING: US National Institutes of Health.


Subject(s)
Biomarkers , COVID-19 , Hospitalization , SARS-CoV-2 , Humans , COVID-19/immunology , COVID-19/mortality , COVID-19/blood , Prospective Studies , Male , Female , Biomarkers/blood , Middle Aged , SARS-CoV-2/immunology , Aged , Hospitalization/statistics & numerical data , Fibrin Fibrinogen Degradation Products/analysis , Antibodies, Monoclonal, Humanized/therapeutic use , Interleukin-6/blood , C-Reactive Protein/analysis , C-Reactive Protein/metabolism , Pandemics , Coronavirus Infections/immunology , Coronavirus Infections/blood , Coronavirus Infections/mortality , Coronavirus Infections/drug therapy , Coronavirus Infections/virology , Pneumonia, Viral/immunology , Pneumonia, Viral/blood , Pneumonia, Viral/mortality , Pneumonia, Viral/drug therapy , Pneumonia, Viral/virology , Treatment Outcome
3.
J Infect Dis ; 229(3): 671-679, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-37948759

ABSTRACT

BACKGROUND: Neutralizing monoclonal antibodies (nmAbs) failed to show clear benefit for hospitalized patients with coronavirus disease 2019 (COVID-19). Dynamics of virologic and immunologic biomarkers remain poorly understood. METHODS: Participants enrolled in the Therapeutics for Inpatients with COVID-19 trials were randomized to nmAb versus placebo. Longitudinal differences between treatment and placebo groups in levels of plasma nucleocapsid antigen (N-Ag), anti-nucleocapsid antibody, C-reactive protein, interleukin-6, and D-dimer at enrollment, day 1, 3, and 5 were estimated using linear mixed models. A 7-point pulmonary ordinal scale assessed at day 5 was compared using proportional odds models. RESULTS: Analysis included 2149 participants enrolled between August 2020 and September 2021. Treatment resulted in 20% lower levels of plasma N-Ag compared with placebo (95% confidence interval, 12%-27%; P < .001), and a steeper rate of decline through the first 5 days (P < .001). The treatment difference did not vary between subgroups, and no difference was observed in trajectories of other biomarkers or the day 5 pulmonary ordinal scale. CONCLUSIONS: Our study suggests that nmAb has an antiviral effect assessed by plasma N-Ag among hospitalized patients with COVID-19, with no blunting of the endogenous anti-nucleocapsid antibody response. No effect on systemic inflammation or day 5 clinical status was observed. CLINICAL TRIALS REGISTRATION: NCT04501978.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Monoclonal/therapeutic use , Biomarkers
4.
ASAIO J ; 69(12): 1090-1098, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37774695

ABSTRACT

To address the unmet clinical need for pediatric circulatory support, we are developing an operationally versatile, hybrid, continuous-flow, total artificial heart ("Dragon Heart"). This device integrates a magnetically levitated axial and centrifugal blood pump. Here, we utilized a validated axial flow pump, and we focused on the development of the centrifugal pump. A motor was integrated to drive the centrifugal pump, achieving 50% size reduction. The motor design was simulated by finite element analysis, and pump design improvement was attained by computational fluid dynamics. A prototype centrifugal pump was constructed from biocompatible 3D printed parts for the housing and machined metal parts for the drive system. Centrifugal prototype testing was conducted using water and then bovine blood. The fully combined device ( i.e. , axial pump nested inside of the centrifugal pump) was tested to ensure proper operation. We demonstrated the hydraulic performance of the two pumps operating in tandem, and we found that the centrifugal blood pump performance was not adversely impacted by the simultaneous operation of the axial blood pump. The current iteration of this design achieved a range of operation overlapping our target range. Future design iterations will further reduce size and incorporate complete and active magnetic levitation.


Subject(s)
Heart Failure , Heart, Artificial , Heart-Assist Devices , Humans , Child , Animals , Cattle , Prosthesis Design , Hydrodynamics , Equipment Design
5.
Artif Organs ; 47(4): 680-694, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36524792

ABSTRACT

BACKGROUND: The purpose of this research is to address ongoing device shortfalls for pediatric patients by developing a novel pediatric hybrid total artificial heart (TAH). The valveless magnetically-levitated MCS device (Dragon Heart) has only two moving parts, integrates an axial and centrifugal blood pump into a single device, and will occupy a compact footprint within the chest for the pediatric patient population. METHODS: Prior work on the Dragon Heart focused on the development of pump designs to achieve hemodynamic requirements. The impeller of these pumps was shaft-driven and thus could not be integrated for testing. The presented research leverages an existing magnetically levitated axial flow pump and focuses on centrifugal pump development. Using the axial pump diameter as a geometric constraint, a shaftless, magnetically supported centrifugal pump was designed for placement circumferentially around the axial pump domain. The new design process included the computational analysis of more than 50 potential centrifugal impeller geometries. The resulting centrifugal pump designs were prototyped and tested for levitation and no-load rotation, followed by in vitro testing using a blood analog. To meet physiologic demands, target performance goals were pressure rises exceeding 90 mm Hg for flow rates of 1-5 L/min with operating speeds of less than 5000 RPM. RESULTS: Three puck-shaped, channel impellers for the centrifugal blood pump were selected based on achieving performance and space requirements for magnetic integration. A quasi-steady flow analysis revealed that the impeller rotational position led to a pulsatile component in the pressure generation. After prototyping, the centrifugal prototypes (3, 4, and 5 channeled designs) demonstrated levitation and no-load rotation. Hydraulic experiments established pressure generation capabilities beyond target requirements. The pressure-flow performance of the prototypes followed expected trends with a dependence on rotational speed. Pulsatile blood flow was observed without pump-speed modulation due to rotating channel passage frequency. CONCLUSION: The results are promising in the advancement of this pediatric TAH. The channeled impeller design creates pressure-flow curves that are decoupled from the flow rate, a benefit that could reduce the required controller inputs and improve treatment of hypertensive patients.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Child , Humans , Magnets , Prosthesis Design , Pulsatile Flow , Magnetics , Equipment Design
6.
J Card Surg ; 37(12): 5172-5186, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36403254

ABSTRACT

There continues to be an unmet therapeutic need for an alternative treatment strategy for respiratory distress and lung disease. We are developing a portable cardiopulmonary support system that integrates an implantable oxygenator with a hybrid, dual-support, continuous-flow total artificial heart (TAH). The TAH has a centrifugal flow pump that is rotating about an axial flow pump. By attaching the hollow fiber bundle of the oxygenator to the base of the TAH, we establish a new cardiopulmonary support technology that permits a patient to be ambulatory during usage. In this study, we investigated the design and improvement of the blood flow pathway from the inflow-to-outflow of four oxygenators using a mathematical model and computational fluid dynamics (CFD). Pressure loss and gas transport through diffusion were examined to assess oxygenator design. The oxygenator designs led to a resistance-driven pressure loss range of less than 35 mmHg for flow rates of 1-7 L/min. All of the designs met requirements. The configuration having an outside-to-inside blood flow direction was found to have higher oxygen transport. Based on this advantageous flow direction, two designs (Model 1 and 3) were then integrated with the axial-flow impeller of the TAH for simulation. Flow rates of 1-7 L/min and speeds of 10,000-16,000 RPM were analyzed. Blood damage studies were performed, and Model 1 demonstrated the lowest potential for hemolysis. Future work will focus on developing and testing a physical prototype for integration into the new cardiopulmonary assist system.


Subject(s)
Heart, Artificial , Oxygenators , Humans , Equipment Design , Hemodynamics
7.
J Card Surg ; 37(11): 3711-3712, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36047368

ABSTRACT

Prenatal diagnosis of hypoplastic aortic arch and coarctation of aorta is still challenging and remains one of the most difficult cardiac defects to diagnose. The results reveal a significant improvement of prenatal diagnosis of hypoplastic arch and coarctation of aorta. The data also shows the significant overlapping of fetal aortic isthmus z score between the infants who need the arch procedure and those who do not.


Subject(s)
Aortic Coarctation , Aorta , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/surgery , Female , Humans , Infant , Pregnancy , Prenatal Diagnosis
8.
PLoS One ; 17(9): e0273914, 2022.
Article in English | MEDLINE | ID: mdl-36107966

ABSTRACT

In response to the COVID-19 pandemic, COVID-19 vaccines have been developed, and the World Health Oraganization (WHO) has granted emergency use listing to multiple vaccines. Studies of vaccine immunogenicity data from implementing COVID-19 vaccines by national immunization programs in single studies spanning multiple countries and continents are limited but critically needed to answer public health questions on vaccines, such as comparing immune responses to different vaccines and among different populations.


Subject(s)
COVID-19 , Vaccines , COVID-19/prevention & control , COVID-19 Vaccines , Cohort Studies , Humans , Pandemics/prevention & control
9.
Front Cardiovasc Med ; 9: 886874, 2022.
Article in English | MEDLINE | ID: mdl-35990958

ABSTRACT

Clinically-available blood pumps and total artificial hearts for pediatric patients continue to lag well behind those developed for adults. We are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). The hybrid TAH design integrates both an axial and centrifugal blood pump within a single, compact housing. The centrifugal pump rotates around the separate axial pump domain, and both impellers rotate around a common central axis. Here, we concentrate our development effort on the centrifugal blood pump by performing computational fluid dynamics (CFD) analysis of the blood flow through the pump. We also conducted transient CFD analyses (quasi-steady and transient rotational sliding interfaces) to assess the pump's dynamic performance conditions. Through modeling, we estimated the pressure generation, scalar stress levels, and fluid forces exerted on the magnetically levitated impellers. To further the development of the centrifugal pump, we also built magnetically-supported prototypes and tested these in an in vitro hydraulic flow loop and via 4-h blood bag hemolytic studies (n = 6) using bovine blood. The magnetically levitated centrifugal prototype delivered 0-6.75 L/min at 0-182 mmHg for 2,750-4,250 RPM. Computations predicted lower pressure-flow performance results than measured by testing; axial and radial fluid forces were found to be <3 N, and mechanical power usage was predicted to be <5 Watts. Blood damage indices (power law weighted exposure time and scalar stress) were <2%. All data trends followed expectations for the centrifugal pump design. Six peaks in the pressure rise were observed in the quasi-steady and transient simulations, correlating to the blade passage frequency of the 6-bladed impeller. The average N.I.H value (n = 6) was determined to be 0.09 ± 0.02 g/100 L, which is higher than desired and must be addressed through design improvement. These data serve as a strong foundation to build upon in the next development phase, whereby we will integrate the axial flow pump component.

10.
J Card Surg ; 37(10): 2988-2990, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35842815

ABSTRACT

Cervantes-Salazar and colleagues report the long-term surgical outcomes of 414 patients with total anomalous pulmonary venous connection (TAPVC) from January 2003 to June 2019. With an overall survival rate of 87.2% from 2003 to 2019, the authors found that an increased mortality risk was associated with infracardiac TAPVC, pulmonary venous obstruction, and postoperative mechanical ventilation. Their comprehensive study with a large sample size of varying age groups, and patients with late referrals for surgery, provide valuable insight into TAPVC surgical outcomes. Improved survival for these patients continues to be a major goal of clinical teams striving to transform treatment paradigms. The promising result of the study reported by Cervantes-Salazar and colleagues gives our field hope for a better future for these patients.


Subject(s)
Pulmonary Veins , Pulmonary Veno-Occlusive Disease , Scimitar Syndrome , Child , Humans , Infant , Postoperative Period , Pulmonary Circulation , Pulmonary Veins/abnormalities , Pulmonary Veins/surgery , Pulmonary Veno-Occlusive Disease/surgery , Retrospective Studies , Scimitar Syndrome/surgery
11.
J Card Surg ; 37(7): 2166-2167, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35485638

ABSTRACT

Thousands of neonates are born each year with complex congenital heart defects, such as total anomalous pulmonary venous connection combined with single ventricle physiology. This dual diagnosis with significant vessel and ventricular complexity requires alternative additional imaging to fully visualize the anatomical challenge and devise the appropriate treatment strategy for the patient.


Subject(s)
Heart Defects, Congenital , Pulmonary Veins , Scimitar Syndrome , Child , Decision Making , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Humans , Infant, Newborn , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Retrospective Studies , Scimitar Syndrome/diagnostic imaging , Scimitar Syndrome/surgery , Tomography
12.
Artif Organs ; 46(8): 1475-1490, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35357020

ABSTRACT

BACKGROUND: Mechanical circulatory support (MCS) devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), have become a vital therapeutic option in the treatment of end-stage heart failure for adult patients. Such therapeutic options continue to be limited for pediatric patients. Clinicians initially adapted or scaled existing adult devices for pediatric patients; however, these adult devices are not designed to support the anatomical structure and varying flow capacities required for this population and are generally operated "off-design," which risks complications such as hemolysis and thrombosis. Devices designed specifically for the pediatric population which seek to address these shortcomings are now emerging and gaining FDA approval. METHODS: To analyze the competitive landscape of pediatric MCS devices, we conducted a systematic literature review. Approximately 27 devices were studied in detail: 8 were established or previously approved designs, and 19 were under development (11 VADs, 5 Fontan assist devices, and 3 TAHs). RESULTS: Despite significant progress, there is still no pediatric pump technology that satisfies the unique and distinct design constraints and requirements to support pediatric patients, including the wide range of patient sizes, increased cardiovascular demand with growth, and anatomic and physiologic heterogeneity of congenital heart disease. CONCLUSIONS: Forward-thinking design solutions are required to overcome these challenges and to ensure the translation of new therapeutic MCS devices for pediatric patients.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Heart, Artificial , Heart-Assist Devices , Child , Heart Failure/surgery , Heart, Artificial/adverse effects , Heart-Assist Devices/adverse effects , Humans , Technology
13.
J Card Surg ; 36(10): 3698-3701, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34338369

ABSTRACT

WeChat and access to wireless communication may offer a continuum of care following medical and surgical intervention. This cardiac surgery research study evaluates the process of parental education and social support following pediatric cardiac surgery utilizing standard of care compared to telehealth.


Subject(s)
Cardiac Surgical Procedures , Telemedicine , Child , Humans , Parents , Prospective Studies , Quality of Life
17.
Artif Organs ; 45(6): 537-541, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33998682

ABSTRACT

Neonates, infants, and children have unique physiology and body surface areas that dramatically change during growth and development, and the substantial diversity of complicated pediatric illnesses and rare childhood diseases are distinct from the adult sphere. Unfortunately, medical innovation is generally constrained to retrofitting adult treatment strategies for this heterogeneous population. This conventional, but limited, approach ignores the dynamic biopsychosocial, growth, and developmental complexities that abound, as one progresses through this life cycle from newborn onward toward early adulthood. Forward-thinking solutions are essential to advance the state-of-the-art to address the challenges and unmet clinical needs that are uniquely presented by the pediatric population, and it has become obvious that newly trained engineers are essential for success. These unmet clinical needs and the necessity of new technical skills and expertise give rise to the emergence of an entirely new field of engineering and applied science: Pediatric Engineering. The field of Pediatric Engineering flips conventional wisdom that adult therapies can simply be scaled or successfully modified for children. It commandeers design to suit the specific needs of the child, while anticipating the dynamic growth and development into adulthood. We are growing a new pipeline of educated scientists and engineers who will have developed a unique toolbox of skills that they can use to tackle unmet clinical needs in global pediatric healthcare for years to come.


Subject(s)
Artificial Organs/trends , Biomedical Engineering/trends , Diffusion of Innovation , Pediatrics/trends , Humans
19.
Ann Biomed Eng ; 49(3): 950-958, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33638028

ABSTRACT

The purpose of this article is to demonstrate how a new cross-community leadership team came together, collaborated, coordinated across academic units with external community partners, and executed a joint mission to address the unmet clinical need for medical face shields during these unprecedented times. Key aspects of this success include the ability to forge and leverage new opportunities, overcome challenges, adapt to changing constraints, and serve the significant need across the Philadelphia region and healthcare systems. We teamed to design-build durable face shields (AJFlex Shields). This was accomplished by high-volume manufacturing via injection molding and by 3-D printing the key headband component that supports the protective shield. Partnering with industry collaborators and civic-minded community allies proved to be essential to bolster production and deliver approximately 33,000 face shields to more than 100 organizations in the region. Our interdisciplinary team of engineers, clinicians, product designers, manufacturers, distributors, and dedicated volunteers is committed to continuing the design-build effort and providing Drexel AJFlex Shields to our communities.


Subject(s)
COVID-19/prevention & control , Manufacturing Industry , Personal Protective Equipment/supply & distribution , Printing, Three-Dimensional , Universities , Equipment Design , Humans , Intersectoral Collaboration , Philadelphia
20.
Breast Cancer Res Treat ; 186(3): 625-635, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33517522

ABSTRACT

PURPOSE: To examine how treatment delays brought on by the COVID-19 pandemic impacted the physical and emotional well-being of physicians treating these patients. METHODS: A cross-sectional survey of physician breast specialists was posted from April 23rd to June 11th, 2020 on membership list serves and social media platforms of the National Accreditation Program for Breast Centers and the American Society of Breast Surgeons. Physician well-being was measured using 6 COVID-19 burnout emotions and the 4-item PROMIS short form for anxiety and sleep disturbance. We examined associations between treatment delays and physician well-being, adjusting for demographic factors, COVID-19 testing and ten COVID-19 pandemic concerns. RESULTS: 870 physicians completed the survey, 61% were surgeons. The mean age of physicians was 52 and 548 (63.9%) were female. 669 (79.4%) reported some delay in patient care as a result of the COVID-19 pandemic. 384 (44.1%) and 529 (60.8%) of physicians scored outside normal limits for anxiety and sleep disturbance, respectively. After adjusting for demographic factors and COVID-19 testing, mean anxiety and COVID-19 burnout scores were significantly higher among physicians whose patients experienced either delays in surgery, adjuvant chemotherapy, radiation, breast imaging or specialty consultation. A multivariable model adjusting for ten physician COVID-19 concerns and delays showed that "delays will impact my emotional well-being" was the strongest concern associated with anxiety, sleep disturbance and COVID-19 burnout factors. CONCLUSIONS: Breast cancer treatment delays during the initial surge of the COVID-19 pandemic in the United States were associated with a negative impact on physician emotional wellness.


Subject(s)
Breast Neoplasms/therapy , Burnout, Professional , COVID-19 , Oncologists , Time-to-Treatment , Anxiety/psychology , Breast Neoplasms/mortality , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Oncologists/psychology , Sleep , Surgeons/psychology , Surveys and Questionnaires , United States
SELECTION OF CITATIONS
SEARCH DETAIL