Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
J Bras Pneumol ; 48(1): e20210337, 2022.
Article in English, Portuguese | MEDLINE | ID: mdl-35293487

ABSTRACT

OBJECTIVE: VEGF-D is a potential biomarker for lymphangioleiomyomatosis (LAM); however, its diagnostic performance has yet to be systematically studied. METHODS: We searched PubMed, EMBASE, Scopus, Web of Science, and Cochrane Library to identify primary studies on VEGF-D in relation to the diagnosis of LAM. The quality of the studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Summary estimates of diagnostic accuracy were pooled using a bivariate random effects model. Subgroup and sensitivity analyses were performed to explore possible heterogeneity. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) was applied to rate the quality of evidence and indicate the strength of recommendations. RESULTS: Ten studies involving 945 patients were of high risk in quality, as assessed using the QUADAS-2. The pooled diagnostic parameters were indicated as follows: sensitivity = 0.82 (95% CI, 0.71-0.90); specificity = 0.98 (95% CI, 0.94-0.99); and diagnostic OR = 197 (95% CI, 66-587). The AUC of summary ROC analysis was 0.98. The subgroup and sensitivity analyses revealed that the overall performance was not substantially affected by the composition of the control group, prespecified cutoff value, the country of origin, or different cutoff values (p > 0.05 for all). A strong recommendation for serum VEGF-D determination to aid in the diagnosis of LAM was made according to the GRADE. CONCLUSIONS: VEGF-D seems to have great potential implications for the diagnosis of LAM in clinical practice due to its excellent specificity and suboptimal sensitivity.


Subject(s)
Lymphangioleiomyomatosis , Biomarkers , Humans , Lymphangioleiomyomatosis/diagnosis , ROC Curve , Sensitivity and Specificity , Vascular Endothelial Growth Factor D
2.
Am J Hypertens ; 35(1): 54-64, 2022 01 05.
Article in English | MEDLINE | ID: mdl-34505630

ABSTRACT

OBJECTIVE: To address to what extent central hemodynamic measurements, improve risk stratification, and determine outcome-based diagnostic thresholds, we constructed the International Database of Central Arterial Properties for Risk Stratification (IDCARS), allowing a participant-level meta-analysis. The purpose of this article was to describe the characteristics of IDCARS participants and to highlight research perspectives. METHODS: Longitudinal or cross-sectional cohort studies with central blood pressure measured with the SphygmoCor devices and software were included. RESULTS: The database included 10,930 subjects (54.8% women; median age 46.0 years) from 13 studies in Europe, Africa, Asia, and South America. The prevalence of office hypertension was 4,446 (40.1%), of which 2,713 (61.0%) were treated, and of diabetes mellitus was 629 (5.8%). The peripheral and central systolic/diastolic blood pressure averaged 129.5/78.7 mm Hg and 118.2/79.7 mm Hg, respectively. Mean aortic pulse wave velocity was 7.3 m per seconds. Among 6,871 participants enrolled in 9 longitudinal studies, the median follow-up was 4.2 years (5th-95th percentile interval, 1.3-12.2 years). During 38,957 person-years of follow-up, 339 participants experienced a composite cardiovascular event and 212 died, 67 of cardiovascular disease. CONCLUSIONS: IDCARS will provide a unique opportunity to investigate hypotheses on central hemodynamic measurements that could not reliably be studied in individual studies. The results of these analyses might inform guidelines and be of help to clinicians involved in the management of patients with suspected or established hypertension.


Subject(s)
Cardiovascular Diseases , Hypertension , Blood Pressure/physiology , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cross-Sectional Studies , Female , Humans , Hypertension/diagnosis , Hypertension/epidemiology , Male , Middle Aged , Pulse Wave Analysis
3.
J. bras. pneumol ; J. bras. pneumol;48(1): e20210337, 2022. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1365042

ABSTRACT

ABSTRACT Objective: VEGF-D is a potential biomarker for lymphangioleiomyomatosis (LAM); however, its diagnostic performance has yet to be systematically studied. Methods: We searched PubMed, EMBASE, Scopus, Web of Science, and Cochrane Library to identify primary studies on VEGF-D in relation to the diagnosis of LAM. The quality of the studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Summary estimates of diagnostic accuracy were pooled using a bivariate random effects model. Subgroup and sensitivity analyses were performed to explore possible heterogeneity. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) was applied to rate the quality of evidence and indicate the strength of recommendations. Results: Ten studies involving 945 patients were of high risk in quality, as assessed using the QUADAS-2. The pooled diagnostic parameters were indicated as follows: sensitivity = 0.82 (95% CI, 0.71-0.90); specificity = 0.98 (95% CI, 0.94-0.99); and diagnostic OR = 197 (95% CI, 66-587). The AUC of summary ROC analysis was 0.98. The subgroup and sensitivity analyses revealed that the overall performance was not substantially affected by the composition of the control group, prespecified cutoff value, the country of origin, or different cutoff values (p > 0.05 for all). A strong recommendation for serum VEGF-D determination to aid in the diagnosis of LAM was made according to the GRADE. Conclusions: VEGF-D seems to have great potential implications for the diagnosis of LAM in clinical practice due to its excellent specificity and suboptimal sensitivity.


RESUMO Objetivo: O VEGF-D é um potencial biomarcador para linfangioleiomiomatose (LAM); entretanto, seu desempenho diagnóstico ainda não foi sistematicamente estudado. Métodos: Foram realizadas buscas nos bancos de dados PubMed, EMBASE, Scopus, Web of Science e Cochrane Library para identificar estudos primários sobre o VEGF-D com relação ao diagnóstico de LAM. A qualidade dos estudos foi avaliada por meio da ferramenta Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). As estimativas sumárias de acurácia diagnóstica foram combinadas utilizando um modelo bivariado de efeitos aleatórios. Análises de subgrupo e de sensibilidade foram realizadas para explorar possíveis heterogeneidades. O sistema Grading of Recommendations Assessment, Development, and Evaluation (GRADE) foi aplicado para avaliar a qualidade das evidências e indicar a força das recomendações. Resultados: Dez estudos envolvendo 945 pacientes eram de alto risco em qualidade, segundo a ferramenta QUADAS-2. Os parâmetros diagnósticos combinados foram indicados da seguinte forma: sensibilidade = 0,82 (IC95%: 0,71-0,90); especificidade = 0,98 (IC95%: 0,94-0,99); e OR diagnóstica = 197 (IC95%: 66-587). A ASC da análise summary ROC foi de 0,98. As análises de subgrupo e de sensibilidade revelaram que o desempenho global não foi substancialmente afetado pela composição do grupo controle, valor de corte pré-especificado, país de origem ou diferentes valores de corte (p > 0,05 para todos). Uma forte recomendação para a dosagem de VEGF-D sérico para auxiliar no diagnóstico de LAM foi feita de acordo com o sistema GRADE. Conclusões: O VEGF-D parece ter grandes implicações potenciais para o diagnóstico de LAM na prática clínica em virtude da excelente especificidade e sensibilidade subótima.


Subject(s)
Humans , Lymphangioleiomyomatosis/diagnosis , Biomarkers , ROC Curve , Sensitivity and Specificity , Vascular Endothelial Growth Factor D
4.
Article in Spanish | PAHO-IRIS | ID: phr-51862

ABSTRACT

[RESUMEN]. La Comisión Lancet de Hipertensión determinó que una medida clave para responder a la carga mundial que representa la hipertensión arterial era mejorar la calidad de las mediciones de la presión arterial, mediante la utilización de dispositivos cuya exactitud haya sido validada. En la actualidad existen 3000 dispositivos comercializados, pero muchos no tienen datos publicados sobre pruebas de exactitud conformes a las normas científicas establecidas. La falta de regulación o su ineficiencia, que permiten la autorización de dispositivos para uso comercial sin una validación oficial, posibilitan este problema. Además, han surgido tecnologías nuevas de medición de la presión arterial (por ejemplo, los sensores sin brazalete) sobre las cuales no existe unanimidad en la comunidad científica con respecto a las normas de exactitud de la medición. En conjunto, estos aspectos contribuyen a la disponibilidad generalizada de tensiómetros de consultorio o domiciliarios que ofrecen una exactitud limitada o incierta, que llevan a diagnósticos, manejo y farmacoterapia inapropiados de la hipertensión a escala mundial. Los problemas más importantes relacionados con la exactitud de los dispositivos de medición de la presión arterial se pueden resolver mediante el requisito regulatorio de una validación independiente obligatoria de los dispositivos, en consonancia con la norma ISO universalmente aceptada. Esta es una recomendación básica y constituye una necesidad internacional acuciante. Otras recomendaciones clave son la elaboración de normas de validación específicas para las tecnologías nuevas de medición de la presión arterial y la publicación en línea de listas de los dispositivos nuevos exactos que están a la disposición de los usuarios y los profesionales de salud. Las recomendaciones están en consonancia con las políticas de la Organización Mundial de la Salud sobre los dispositivos médicos y la atención universal de la salud. El cumplimiento de las recomendaciones aumentará la disponibilidad mundial de dispositivos de medición de la presión arterial que sean exactos y tendrá como efecto un mejor diagnóstico y tratamiento, reduciendo así la carga mundial de la hipertensión.


[ABSTRACT]. The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3 000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organization for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP.


[RESUMO]. A Comissão Lancet sobre Hipertensão Arterial identificou que uma iniciativa central para enfrentar a carga mundial da hipertensão arterial seria a melhoria na qualidade da mensuração da pressão arterial pelo uso aparelhos de pressão arterial validados quanto à acurácia. Atualmente, existem mais de 3 000 aparelhos de pressão arterial disponíveis comercialmente; entretanto, muitos não têm dados publicados sobre testes de acurácia realizados de acordo com padrões científicos estabelecidos. Este problema resulta de regulamentação fraca ou inexistente, o que permite a aprovação para uso comercial de dispositivos sem validação formal. Além disso, surgiram novas tecnologias de mensuração da pressão arterial (por exemplo, sensores sem algemas) sem consenso científico quanto aos padrões de acurácia. No conjunto, essas questões contribuem para a oferta generalizada de dispositivos de pressão arterial clínica e domiciliar com acurácia limitada ou incerta, levando a diagnóstico, gerenciamento e tratamento inadequados da hipertensão em escala global. Os problemas mais significativos relacionados com a acurácia dos dispositivos de pressão arterial podem ser resolvidos por regulamentação que imponha a obrigatoriedade de validação independente dos aparelhos de pressão arterial, de acordo com a norma universalmente aceita pela Organização Internacional de Normalização. Esta é uma recomendação fundamental para a qual existe uma necessidade internacional urgente. Outras recomendações essenciais incluem o desenvolvimento de padrões de validação especificamente para novas tecnologias de mensuração da pressão arterial e listas on-line de aparelhos com acurácia adequada que sejam acessíveis aos consumidores e profissionais de saúde. As recomendações estão alinhadas com as políticas da Organização Mundial da Saúde (OMS) sobre dispositivos médicos e atenção universal à saúde. A adesão às recomendações aumentaria a oferta global de dispositivos de pressão arterial com acurácia adequada e resultaria em melhor diagnóstico e tratamento da hipertensão arterial, diminuindo assim a carga mundial dessa doença.


Subject(s)
Global Health , Biomedical Technology , Reference Standards , Diagnostic Equipment , Global Health , Biomedical Technology , Reference Standards , Diagnostic Equipment , Global Health , Biomedical Technology , Reference Standards , Diagnostic Equipment
5.
Rev. panam. salud pública ; 44: e21, 2020. tab
Article in Spanish | LILACS | ID: biblio-1101778

ABSTRACT

Objetivos. El boletín de notas de México correspondiente al 2018 evalúa las oportunidades a disposición de la población infantil y joven mexicana para que puedan desarrollar niveles adecuados de actividad física y sueño, y disminuyan el sedentarismo.Métodos. El boletín es un sistema de vigilancia que recopila los datos obtenidos en las encuestas nacionales, censos, documentos gubernamentales, sitios web, literatura gris y estudios publicados con respecto al análisis de 16 indicadores en 4 categorías: comportamientos diarios, estado físico, entornos y fuentes influyentes, y estrategias e inversión. Los datos fueron cotejados con los puntos de referencia establecidos. A cada indicador se le asignó una calificación entre 1 y 10 (< 6 significa reprobado) o fue marcado como "incompleto" si los datos eran nulos o insuficientes. Resultados. Las calificaciones obtenidas para los comportamientos diarios fueron: actividad física en general: 4; participación en actividades deportivas organizadas: 5; juego activo: 3; modalidades de transporte activas: 5; sueño: 7; y sedentarismo: 3. El estado físico obtuvo un 7. Las calificaciones para los entornos y fuentes influyentes fueron: familiares y pares: "incompleto"; escuela: 3; comunidad y entorno: 4. Para las estrategias e inversión: estrategias gubernamentales: 6; entidades no gubernamentales: 2.Conclusiones. Las bajas calificaciones obtenidas en 11 de los 16 indicadores demuestran que las escuelas, las familias, las comunidades y el gobierno tienen que aunar esfuerzos para mejorar las oportunidades que tiene la población infantil y joven en México para desarrollar niveles de actividad física satisfactorios.(AU)


ABSTRACT The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3 000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organization for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP.(AU)


RESUMO A Comissão Lancet sobre Hipertensão Arterial identificou que uma iniciativa central para enfrentar a carga mundial da hipertensão arterial seria a melhoria na qualidade da mensuração da pressão arterial pelo uso aparelhos de pressão arterial validados quanto à acurácia. Atualmente, existem mais de 3 000 aparelhos de pressão arterial disponíveis comercialmente; entretanto, muitos não têm dados publicados sobre testes de acurácia realizados de acordo com padrões científicos estabelecidos. Este problema resulta de regulamentação fraca ou inexistente, o que permite a aprovação para uso comercial de dispositivos sem validação formal. Além disso, surgiram novas tecnologias de mensuração da pressão arterial (por exemplo, sensores sem algemas) sem consenso científico quanto aos padrões de acurácia. No conjunto, essas questões contribuem para a oferta generalizada de dispositivos de pressão arterial clínica e domiciliar com acurácia limitada ou incerta, levando a diagnóstico, gerenciamento e tratamento inadequados da hipertensão em escala global. Os problemas mais significativos relacionados com a acurácia dos dispositivos de pressão arterial podem ser resolvidos por regulamentação que imponha a obrigatoriedade de validação independente dos aparelhos de pressão arterial, de acordo com a norma universalmente aceita pela Organização Internacional de Normalização. Esta é uma recomendação fundamental para a qual existe uma necessidade internacional urgente. Outras recomendações essenciais incluem o desenvolvimento de padrões de validação especificamente para novas tecnologias de mensuração da pressão arterial e listas on-line de aparelhos com acurácia adequada que sejam acessíveis aos consumidores e profissionais de saúde. As recomendações estão alinhadas com as políticas da Organização Mundial da Saúde (OMS) sobre dispositivos médicos e atenção universal à saúde. A adesão às recomendações aumentaria a oferta global de dispositivos de pressão arterial com acurácia adequada e resultaria em melhor diagnóstico e tratamento da hipertensão arterial, diminuindo assim a carga mundial dessa doença.(AU)


Subject(s)
Global Health/trends , Diagnostic Equipment/standards , Biomedical Technology , Arterial Pressure , Reference Standards
6.
Acta Cir Bras ; 34(8): e201900802, 2019.
Article in English | MEDLINE | ID: mdl-31618402

ABSTRACT

PURPOSE: To reveal the function of miR-134 in myocardial ischemia. METHODS: Real-time PCR and western blotting were performed to measure the expression of miR-134, nitric oxide synthase 3 (NOS3) and apoptotic-associated proteins. Lactic dehydrogenase (LDH) assay, cell counting kit-8 (CCK-8), Hoechst 33342/PI double staining and flow cytometry assay were implemented in H9c2 cells, respectively. MiR-134 mimic/inhibitor was used to regulate miR-134 expression. Bioinformatic analysis and luciferase reporter assay were utilized to identify the interrelation between miR-134 and NOS3. Rescue experiments exhibited the role of NOS3. The involvement of PI3K/AKT was assessed by western blot analysis. RESULTS: MiR-134 was high regulated in the myocardial ischemia model, and miR-134 mimic/inhibitor transfection accelerated/impaired the speed of cell apoptosis and attenuated/exerted the cell proliferative prosperity induced by H/R regulating active status of PI3K/AKT signaling. LDH activity was also changed due to the different treatments. Moreover, miR-134 could target NOS3 directly and simultaneously attenuated the expression of NOS3. Co-transfection miR-134 inhibitor and pcDNA3.1-NOS3 highlighted the inhibitory effects of miR-134 on myocardial H/R injury. CONCLUSION: This present work puts insights into the crucial effects of the miR-134/NOS3 axis in myocardial H/R injury, delivering a potential therapeutic technology in future.


Subject(s)
Hypoxia/metabolism , MicroRNAs/metabolism , Myocardial Reperfusion Injury/metabolism , Nitric Oxide Synthase Type III/metabolism , Animals , Apoptosis/drug effects , Apoptosis/physiology , Cell Proliferation/drug effects , MicroRNAs/genetics , MicroRNAs/therapeutic use , Myocardial Reperfusion Injury/drug therapy , Myocardial Reperfusion Injury/genetics , Myocardial Reperfusion Injury/pathology , Nitric Oxide Synthase Type III/genetics , Nitric Oxide Synthase Type III/therapeutic use , Phosphatidylinositol 3-Kinases/metabolism , Proto-Oncogene Proteins c-akt/metabolism , Rats , Signal Transduction/drug effects
7.
Acta cir. bras. ; 34(8): e201900802, Oct. 14, 2019. tab, graf
Article in English | VETINDEX | ID: vti-744333

ABSTRACT

Abstract Purpose To reveal the function of miR-134 in myocardial ischemia. Methods Real-time PCR and western blotting were performed to measure the expression of miR-134, nitric oxide synthase 3 (NOS3) and apoptotic-associated proteins. Lactic dehydrogenase (LDH) assay, cell counting kit-8 (CCK-8), Hoechst 33342/PI double staining and flow cytometry assay were implemented in H9c2 cells, respectively. MiR-134 mimic/inhibitor was used to regulate miR-134 expression. Bioinformatic analysis and luciferase reporter assay were utilized to identify the interrelation between miR-134 and NOS3. Rescue experiments exhibited the role of NOS3. The involvement of PI3K/AKT was assessed by western blot analysis. Results MiR-134 was high regulated in the myocardial ischemia model, and miR-134 mimic/inhibitor transfection accelerated/impaired the speed of cell apoptosis and attenuated/exerted the cell proliferative prosperity induced by H/R regulating active status of PI3K/AKT signaling. LDH activity was also changed due to the different treatments. Moreover, miR-134 could target NOS3 directly and simultaneously attenuated the expression of NOS3. Co-transfection miR-134 inhibitor and pcDNA3.1-NOS3 highlighted the inhibitory effects of miR-134 on myocardial H/R injury. Conclusion This present work puts insights into the crucial effects of the miR-134/NOS3 axis in myocardial H/R injury, delivering a potential therapeutic technology in future.(AU)


Subject(s)
Myocardial Reperfusion Injury/therapy , MicroRNAs/therapeutic use , Nitric Oxide Synthase Type III , Apoptosis , Cell Proliferation , Polymerase Chain Reaction
8.
Lancet ; 393(10174): 877-888, 2019 03 02.
Article in English | MEDLINE | ID: mdl-30739745

ABSTRACT

BACKGROUND: Systolic blood pressure of more than 185 mm Hg is a contraindication to thrombolytic treatment with intravenous alteplase in patients with acute ischaemic stroke, but the target systolic blood pressure for optimal outcome is uncertain. We assessed intensive blood pressure lowering compared with guideline-recommended blood pressure lowering in patients treated with alteplase for acute ischaemic stroke. METHODS: We did an international, partial-factorial, open-label, blinded-endpoint trial of thrombolysis-eligible patients (age ≥18 years) with acute ischaemic stroke and systolic blood pressure 150 mm Hg or more, who were screened at 110 sites in 15 countries. Eligible patients were randomly assigned (1:1, by means of a central, web-based program) within 6 h of stroke onset to receive intensive (target systolic blood pressure 130-140 mm Hg within 1 h) or guideline (target systolic blood pressure <180 mm Hg) blood pressure lowering treatment over 72 h. The primary outcome was functional status at 90 days measured by shift in modified Rankin scale scores, analysed with unadjusted ordinal logistic regression. The key safety outcome was any intracranial haemorrhage. Primary and safety outcome assessments were done in a blinded manner. Analyses were done on intention-to-treat basis. This trial is registered with ClinicalTrials.gov, number NCT01422616. FINDINGS: Between March 3, 2012, and April 30, 2018, 2227 patients were randomly allocated to treatment groups. After exclusion of 31 patients because of missing consent or mistaken or duplicate randomisation, 2196 alteplase-eligible patients with acute ischaemic stroke were included: 1081 in the intensive group and 1115 in the guideline group, with 1466 (67·4%) administered a standard dose among the 2175 actually given intravenous alteplase. Median time from stroke onset to randomisation was 3·3 h (IQR 2·6-4·1). Mean systolic blood pressure over 24 h was 144·3 mm Hg (SD 10·2) in the intensive group and 149·8 mm Hg (12·0) in the guideline group (p<0·0001). Primary outcome data were available for 1072 patients in the intensive group and 1108 in the guideline group. Functional status (mRS score distribution) at 90 days did not differ between groups (unadjusted odds ratio [OR] 1·01, 95% CI 0·87-1·17, p=0·8702). Fewer patients in the intensive group (160 [14·8%] of 1081) than in the guideline group (209 [18·7%] of 1115) had any intracranial haemorrhage (OR 0·75, 0·60-0·94, p=0·0137). The number of patients with any serious adverse event did not differ significantly between the intensive group (210 [19·4%] of 1081) and the guideline group (245 [22·0%] of 1115; OR 0·86, 0·70-1·05, p=0·1412). There was no evidence of an interaction of intensive blood pressure lowering with dose (low vs standard) of alteplase with regard to the primary outcome. INTERPRETATION: Although intensive blood pressure lowering is safe, the observed reduction in intracranial haemorrhage did not lead to improved clinical outcome compared with guideline treatment. These results might not support a major shift towards this treatment being applied in those receiving alteplase for mild-to-moderate acute ischaemic stroke. Further research is required to define the underlying mechanisms of benefit and harm resulting from early intensive blood pressure lowering in this patient group. FUNDING: National Health and Medical Research Council of Australia; UK Stroke Association; Ministry of Health and the National Council for Scientific and Technological Development of Brazil; Ministry for Health, Welfare, and Family Affairs of South Korea; Takeda.


Subject(s)
Blood Pressure/drug effects , Brain Ischemia/drug therapy , Fibrinolytic Agents/administration & dosage , Stroke/drug therapy , Tissue Plasminogen Activator/administration & dosage , Administration, Intravenous , Aged , Australia/epidemiology , Blood Pressure/physiology , Brain Ischemia/pathology , Brazil/epidemiology , Female , Fibrinolytic Agents/therapeutic use , Humans , Intracranial Hemorrhages/epidemiology , Male , Middle Aged , Practice Guidelines as Topic , Prospective Studies , Republic of Korea/epidemiology , Tissue Plasminogen Activator/therapeutic use , Treatment Outcome
9.
Biosaf Health ; 1(3): 150-154, 2019 Dec.
Article in English | MEDLINE | ID: mdl-32501448

ABSTRACT

Here, we report the identification of Histoplasma causing an unexplained disease cluster in Matthews Ridge, Guyana. In March 2019, 14 employees of Chongqing Bosai Mining Company, China, working in a manganese mining of Guyana, had unexplained fever, and two of them died. We obtained lung and brain tissues as well as the blood samples from the two deceased cases (patient No. 1 and 2), and bronchoscopy lavages and cerebrospinal fluid samples from one severe case (patient No. 3), respectively. All samples were tested by pathological examination, high-throughput sequencing, and real-time PCR. Pathological detection showed the presence of spore-like structures in the lung tissue of patient No. 1, indicating a fungal infection in this patient. Nanopore sequencing identified the existing of H. capsulatum in the lung tissue sample within 13 h. Next-generation sequencing identified specific fragments of H. capsulatum in all of the samples tested (lung, brain and blood serum from the deceased cases, and plasma from the severe case). Real-time PCR assays did not reveal any viral infection related to transmission from bat feces. We conclude that H. capsulatum was the causative pathogen of this disease cluster based on epidemiologic, clinical, pathological and nucleic acid evidence.

10.
Acta cir. bras ; Acta cir. bras;34(8): e201900802, 2019. tab, graf
Article in English | LILACS | ID: biblio-1038128

ABSTRACT

Abstract Purpose To reveal the function of miR-134 in myocardial ischemia. Methods Real-time PCR and western blotting were performed to measure the expression of miR-134, nitric oxide synthase 3 (NOS3) and apoptotic-associated proteins. Lactic dehydrogenase (LDH) assay, cell counting kit-8 (CCK-8), Hoechst 33342/PI double staining and flow cytometry assay were implemented in H9c2 cells, respectively. MiR-134 mimic/inhibitor was used to regulate miR-134 expression. Bioinformatic analysis and luciferase reporter assay were utilized to identify the interrelation between miR-134 and NOS3. Rescue experiments exhibited the role of NOS3. The involvement of PI3K/AKT was assessed by western blot analysis. Results MiR-134 was high regulated in the myocardial ischemia model, and miR-134 mimic/inhibitor transfection accelerated/impaired the speed of cell apoptosis and attenuated/exerted the cell proliferative prosperity induced by H/R regulating active status of PI3K/AKT signaling. LDH activity was also changed due to the different treatments. Moreover, miR-134 could target NOS3 directly and simultaneously attenuated the expression of NOS3. Co-transfection miR-134 inhibitor and pcDNA3.1-NOS3 highlighted the inhibitory effects of miR-134 on myocardial H/R injury. Conclusion This present work puts insights into the crucial effects of the miR-134/NOS3 axis in myocardial H/R injury, delivering a potential therapeutic technology in future.


Subject(s)
Animals , Rats , Myocardial Reperfusion Injury/metabolism , MicroRNAs/metabolism , Nitric Oxide Synthase Type III/metabolism , Hypoxia/metabolism , Myocardial Reperfusion Injury/genetics , Myocardial Reperfusion Injury/pathology , Myocardial Reperfusion Injury/drug therapy , Signal Transduction/drug effects , Apoptosis/drug effects , Apoptosis/physiology , Phosphatidylinositol 3-Kinases/metabolism , MicroRNAs/genetics , MicroRNAs/therapeutic use , Cell Proliferation/drug effects , Nitric Oxide Synthase Type III/genetics , Nitric Oxide Synthase Type III/therapeutic use , Proto-Oncogene Proteins c-akt/metabolism
11.
J Cell Sci ; 131(23)2018 11 30.
Article in English | MEDLINE | ID: mdl-30404831

ABSTRACT

Autophagic dysfunction and protein aggregation have been linked to several neurodegenerative disorders, but the exact mechanisms and causal connections are not clear and most previous work was done in neurons and not in microglial cells. Here, we report that exogenous fibrillary, but not monomeric, alpha-synuclein (AS, also known as SNCA) induces autophagy in microglial cells. We extensively studied the dynamics of this response using both live-cell imaging and correlative light-electron microscopy (CLEM), and found that it correlates with lysosomal damage and is characterised by the recruitment of the selective autophagy-associated proteins TANK-binding kinase 1 (TBK1) and optineurin (OPTN) to ubiquitylated lysosomes. In addition, we observed that LC3 (MAP1LC3B) recruitment to damaged lysosomes was dependent on TBK1 activity. In these fibrillar AS-treated cells, autophagy inhibition impairs mitochondrial function and leads to microglial cell death. Our results suggest that microglial autophagy is induced in response to lysosomal damage caused by persistent accumulation of AS fibrils. Importantly, triggering of the autophagic response appears to be an attempt at lysosomal quality control and not for engulfment of fibrillar AS.This article has an associated First Person interview with the first author of the paper.


Subject(s)
Lysosomes/metabolism , Microglia/metabolism , Protein Serine-Threonine Kinases/genetics , Transcription Factor TFIIIA/genetics , alpha-Synuclein/metabolism , Autophagy , Cell Cycle Proteins , Humans , Membrane Transport Proteins , Protein Serine-Threonine Kinases/metabolism , Signal Transduction , Transcription Factor TFIIIA/metabolism
12.
Sci Rep ; 7: 43153, 2017 03 03.
Article in English | MEDLINE | ID: mdl-28256519

ABSTRACT

Autophagy is a fundamental cellular homeostatic mechanism, whereby cells autodigest parts of their cytoplasm for removal or turnover. Neurodegenerative disorders are associated with autophagy dysregulation, and drugs modulating autophagy have been successful in several animal models. Microglial cells are phagocytes in the central nervous system (CNS) that become activated in pathological conditions and determine the fate of other neural cells. Here, we studied the effects of autophagy on the production of pro-inflammatory molecules in microglial cells and their effects on neuronal cells. We observed that both trehalose and rapamycin activate autophagy in BV2 microglial cells and down-regulate the production of pro-inflammatory cytokines and nitric oxide (NO), in response to LPS and alpha-synuclein. Autophagy also modulated the phosphorylation of p38 and ERK1/2 MAPKs in BV2 cells, which was required for NO production. These actions of autophagy modified the impact of microglial activation on neuronal cells, leading to suppression of neurotoxicity. Our results demonstrate a novel role for autophagy in the regulation of microglial cell activation and pro-inflammatory molecule secretion, which may be important for the control of inflammatory responses in the CNS and neurotoxicity.


Subject(s)
Autophagy , Cell Death/drug effects , Cytokines/metabolism , Lipopolysaccharides/toxicity , Neuroglia/physiology , Nitric Oxide/metabolism , alpha-Synuclein/toxicity , Animals , Cell Line , Mice , Signal Transduction
13.
Genet Mol Biol ; 38(1): 79-85, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25983628

ABSTRACT

The WUSCHEL (WUS)-related homeobox (WOX) gene family coordinates transcription during the early phases of embryogenesis. In this study, a putative WOX2 homolog was isolated and characterized from Aegilops tauschii, the donor of D genome of Triticum aestivum. The sequence consisted of 2045 bp, and contained an open reading frame (ORF), encoded 322 amino acids. The predicted protein sequence contained a highly conserved homeodomain and the WUS-box domain, which is present in some members of the WOX protein family. The full-length ORF was subcloned into prokaryotic expression vector pET-30a, and an approximately 34-kDa protein was expressed in Escherichia coli BL21 (DE3) cells with IPTG induction. The molecular mass of the expressed protein was identical to that predicted by the cDNA sequence. Phylogenetic analysis suggested that Ae. tauschii WOX2 is closely related to the rice and maize orthologs. Quantitative PCR analysis showed that WOX2 from Ae. tauschii was primarily expressed in the seeds; transcription increased during seed development and declined after the embryos matured, suggesting that WOX2 is associated with embryo development in Ae. tauschii.

14.
FASEB J ; 27(1): 299-312, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23073832

ABSTRACT

Microglial cells are phagocytes in the central nervous system (CNS) and become activated in pathological conditions, resulting in microgliosis, manifested by increased cell numbers and inflammation in the affected regions. Thus, controlling microgliosis is important to prevent pathological damage to the brain. Here, we evaluated the contribution of Toll-like receptor 2 (TLR2) to microglial survival. We observed that activation of microglial cells with peptidoglycan (PGN) from Staphylococcus aureus and other TLR2 ligands results in cell activation followed by the induction of autophagy and autophagy-dependent cell death. In C57BL/6J mice, intracerebral injection of PGN increased the autophagy of microglial cells and reduced the microglial/macrophage cell number in brain parenchyma. Our results demonstrate a novel role of TLRs in the regulation of microglial cell activation and survival, which are important for the control of microgliosis and associated inflammatory responses in the CNS.


Subject(s)
Autophagy , Cell Death/physiology , Microglia/cytology , Polysaccharides/physiology , Toll-Like Receptor 2/metabolism , Animals , Blotting, Western , Flow Cytometry , Ligands , Male , Mice , Mice, Inbred C57BL , Microscopy, Confocal , Microscopy, Electron, Transmission , Polysaccharides/metabolism
15.
Neurobiol Dis ; 43(3): 616-24, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21624466

ABSTRACT

Microglial cells are resident macrophages in the central nervous system (CNS) and become activated in many pathological conditions. Activation of microglial cells results in reactive microgliosis, manifested by an increase in cell number in the affected CNS regions. The control of microgliosis may be important to prevent pathological damage to the brain. The type 2 cytokine IL-4 has been reported to be protective in brain inflammation. However, its effect on microglial cell survival was not well understood. In this study, we report a dual effect of IL-4 on the survival of mouse microglial cells. In a 6h short term culture, IL-4 reduced the death of microglial cells induced by staurosporine. In contrast, in long term treatment (more than 48h), IL-4 increased the apoptotic death of both primary mouse microglial cells and a microglial cell line N9. Mechanistic studies revealed that, in microglial cells, IL-4 increased the levels of cleaved caspase 3 and PARP, which is down-stream of activated caspase 3. In addition, IL-4 down regulated the autophagy and the antiapoptotic protein Bcl-xL in microglial cells. On the other hand, the pre-incubation of microglial cells with IL-4 for 24h, attenuated the cell death induced by the neurotoxic peptide amyloid beta 1-42 (Aß42). Our observations demonstrate a novel function of IL-4 in regulating the survival of microglial cells, which may have important significance in reduction of undesired inflammatory responses in the CNS.


Subject(s)
Apoptosis/immunology , Caspase 3/physiology , Interleukin-4/physiology , Microglia/immunology , Amyloid beta-Peptides/toxicity , Animals , Caspase Inhibitors , Cell Survival/immunology , Cells, Cultured , Inflammation Mediators/antagonists & inhibitors , Inflammation Mediators/physiology , Mice , Mice, Inbred C57BL , Microglia/enzymology , Microglia/pathology , Peptide Fragments/toxicity , Poly (ADP-Ribose) Polymerase-1 , Poly(ADP-ribose) Polymerases/biosynthesis , Poly(ADP-ribose) Polymerases/metabolism , Staurosporine/pharmacology
SELECTION OF CITATIONS