Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 422
Filter
1.
ACS Omega ; 9(19): 21260-21269, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38764628

ABSTRACT

Natural gas generates varying concentrations of H2S during natural formation and extraction, and H2S leak accidents are frequent, posing a significant threat to the safety of human life and the environment. Conventional treatment technology equipment is large and does not meet the emergency requirements of the complex topographical gas field. This study aimed to design a pilot-scale method coupling the venturi and bubbling reactors to reduce equipment size and improve emergency capabilities for the absorption of leaked H2S. It found that the ring system self-priming venturi reactor, which was suitable only for the coarse treatment of toxic gases, maintained an absorption efficiency of around 50% under most operating conditions, with substantial variations due to changes in process parameters, but that redundancy of the bubbling reactor was high. With the synergistic effect of venturi and bubbling, the coupling process had an extremely high absorption efficiency, basically more than 95%. The experiments also showed that the H2S concentration at the outlet of the venturi-bubbling reactor increased with increasing inlet gas concentration and gas volume. The absorption performance improved significantly on increasing Fe3+ concentration; it increased first and then remained constant, and the optimum Fe3+ concentration for the absorption of leaked H2S was 21 000 mg/m3. The absorption performance decreased with increasing submergence height and then remained stable after the size of the inlet approached 600 mm, whereas the overall absorption efficiency of the venturi-bubbling reactor remained constant. The optimum operating temperature range was 10 °C-50 °C. The experimental system kept the outlet concentration below the emergency discharge standard for a continuous period of 48 h following practical use in the gas field and resulting in significant enhancement in mass transfer performance, fully satisfying the emergency requirements.

2.
Sci Total Environ ; 919: 170768, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38340838

ABSTRACT

Mangroves are transition areas connecting land, freshwater, and the ocean, where a great amount of organic carbon accumulates in the soil, forming a considerable carbon sink. However, the soil might also be a source of greenhouse gas (GHG) emissions. This study hypothesized that measuring GHG emissions solely during low tides can represent diurnal GHG emissions in mangroves. Methane (CH4) and carbon dioxide (CO2) emissions were quantified during tidal cycles using an ultraportable gas analyzer in Kandelia obovata (without pneumatophores) and Avicennia marina (with pneumatophores) mangroves in summer and fall. The results showed that the CH4 fluxes varied greatly during tidal cycles, from -1.25 to 96.24 µmol CH4 m-2 h-1 for K. obovata and from 2.86 to 2662.00 µmol CH4 m-2 h-1 for A. marina. The CO2 fluxes ranged from -4.23 to 20.65 mmol CO2 m-2 h-1 for K. obovata and from 0.09 to 24.69 mmol CO2 m-2 h-1 for A. marina. The diurnal variation in GHG levels in mangroves is predominantly driven by tidal cycles. The peak emissions of CH4 and CO2 were noted at the beginning of the flooding tide, rather than during daytime or nighttime. While the patterns of the CO2 fluxes during tidal cycles were similar between K. obovata and A. marina mangroves, their CH4 flux patterns during the tidal cycles differed. Possibly due to different transport mechanisms, CO2 emissions are primarily influenced by surface soils, whereas CH4 is predominantly emitted from deeper soils, thus being influenced by root structures. To reduce the uncertainty in measuring GHG emissions in mangrove soils during a tidal cycle, it is advisable to increase the number of GHG flux measurements during the period spanning 30 min before and after the beginning of the flooding and ebbing tides.

3.
Sci Rep ; 14(1): 1405, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38228694

ABSTRACT

Currently, a standardized design and calculation specification for suction drum foundations has yet to exist in China. The engineering design currently depends mainly on the subjective understanding and engineering experience of the designers, which can be considered somewhat blind and subjective. In this paper, we utilize the offshore wind power project in Yangjiang City, Guangdong Province, as our case study. Building upon domestic and international research results, relevant investigations, design specifications, and engineering applications in related fields, we conduct a systematic study on the design calculation and construction control technology of the suction drum foundation. The document presents the design calculation and inspection of the suction drum foundation. Building on this foundation, we propose a sinking feasibility analysis method and a parameter value method for the suction drum foundation calculation. We also examine the suction drum foundation construction process, examining its control parameters, technology, and standards. Finally, based on the measured data from six four-barrel guided frame platform suction drum foundations that were successfully installed, the proposed design and control method are evaluated, and their effectiveness is verified. The results of this study can provide valuable references for the design and construction of similar suction drum foundation platforms.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1020852

ABSTRACT

Objective Explore the relationship between semen quality and trace element levels in seminal plasma,as well as miR-184 levels in exosomes of male infertility patients.Methods 155 male infertility patients in our hospital from January 2022 to July 2023 were selected as the infertility group,and another 155 male patients with normal physical examination during the same period were selected as the normal group.Compare the general information,semen quality parameters,trace elements,and miR-184 levels in exosomes between two groups,and analyze the correlation between male infertility patients and the above laboratory indicators through Spearman rank correlation analysis.Results The sperm concentration,total sperm motility(PR + NP),forward motility sperm(PR),average curve velocity,average linear velocity,average path velocity,and average lateral amplitude of sperm head(ALH)in the infertile group were lower than those in the normal group(P<0.05);The levels of Zn,Mg,and Ca in the infertile group were lower than those in the normal group,while the levels of Cu,Pb,and relative expression of miR-184 were higher than those in the normal group(P<0.05);The levels of Zn and Cu elements in male infertility patients are positively and negatively correlated with sperm concentration,total sperm motility(PR+NP),and forward motility sperm(PR),respectively.The levels of Pb elements are negatively correlated with the average lateral amplitude of sperm head(ALH),and P<0.05.The relative expression level of miR-184 in male infertility patients is negatively correlated with sperm concentration,total sperm motility(PR + NP),forward motility sperm(PR),and average sperm curve velocity,with P<0.05.Conclusion The quality of semen in male infertility patients is closely related to the levels of trace elements in semen and miR-184 levels in exosomes.

5.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1023765

ABSTRACT

Disease animal model is an indispensable part of studying the pathogenesis and treatment of diseases.Review of the ethics and welfare is the necessary measure to ensure the quality of scientific research and promote the scientific and rational use of laboratory animals.In the review practice,it is found that most applicants are difficult to accurately understand the items listed in the application form and ethical principles related to items.Therefore,a practical and feasible set of ethical guidelines for animal experiments is necessary.This review focuses on the legal and ethical basis of developing oral disease animal models,and divides the methods of establishing oral disease animal models into physical methods,chemical methods,biological methods,and combined methods.It also elaborates on the ethical and welfare review points of different modeling methods and model evaluation methods.Hopefully,ethical censors and project applicants may get more understanding of ethical review for disease animal models,and ultimately improve the standardization and applicability of animal models.

6.
China Pharmacist ; (12): 57-65, 2024.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1025920

ABSTRACT

Objective To investigate the compatibility between antiepileptic active pharmaceutical ingredient(API)levetiracetam and binder polyethylene glycol 6000,and provide a basis for evaluating and ensuring the safety of drugs.Methods Levetiracetam and polyethylene glycol 6000 from different producers were mixed in a certain proportion,and placed under different conditions according to the test method of stability influencing factors.The compatibility of levetiracetam and polyethylene glycol 6000 was analyzed by differential scanning calorimetry and HPLC,respectively,and the thermal variations,changes of levetiracetam appearance and related substances were investigated.Results After being placed under high humidity(relative humidity of 90%)and light(4 500 Lx)for 10 days,the compatibility between API and pharmaceutical excipients was proved good,while under the conditions of high temperature of 50℃ and 60℃,polyethylene glycol 6000 interacted with levetiracetam,resulting in the growth of levetiracetam related substances including impurity A and total amount of impurities,along with the production of two unknown impurities.Polyethylene glycol 6000 from different producers and different batches had different effects on the related substances of levetiracetam.Conclusion There is a risk of compatibility between levetiracetam and polyethylene glycol 6000 under elevated temperatures,and it is recommended that preparation producers optimize product prescriptions and improve the quality and safety of drugs.

7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1031535

ABSTRACT

ObjectiveTo establish the reference intervals of thyroid hormones in pregnant women from Sanming city and compare them with those from other areas in China. MethodsThe study recruited 605 pregnant women and 229 non-pregnant healthy women who visited Sanming First Hospital between March 29 and June 28, 2023. Blood samples were sequentially collected from the participants to determine the serum levels of thyroid stimulating hormone (TSH), free triiodothyronine (FT3) and free thyroxine (FT4). The reference intervals of thyroid hormones were established by using a percentile range of P2.5 to P97.5 and their changes in different periods of pregnancy were analyzed and compared with those from other areas in China. ResultsThere were significant differences in levels of TSH, FT4 and FT3 at different periods of pregnancy (all P <0.05). Compared with non-pregnant women, women in first trimester had significantly decreased levels of TSH and FT4, but similar level of FT3. Since the second trimester, TSH level displayed rising tendency, while FT3 and FT4 levels showed gradual decrease. The reference intervals of thyroid hormones in the first, second and third trimester of pregnancy in Sanming city were TSH (0.068, 2.943) μU/mL, FT3 (4.302, 6.888) pmol/L, FT4 (8.240, 14.719) pmol/L; TSH (0.419, 3.274) μU/mL, FT3 (4.074, 6.629) pmol/L, FT4 (6.726, 11.980) pmol/L; TSH (0.422, 3.570) μU/mL, FT3 (3.741, 5.850) pmol/L, FT4 (6.103, 10.347) pmol/L, respectively. Significant differences were found in the reference intervals of thyroid hormones during pregnancy among different areas in China. ConclusionsThe levels of TSH, FT3, FT4 during pregnancy are different from those during non-pregnancy, and also significantly differ in different periods of pregnancy. Reference intervals of thyroid hormones in pregnant women are affected by various factors such as geographic location, ethnicity and laboratory test method, etc. Therefore, establishing the population-specific reference intervals of thyroid hormones will benefit for the diagnosis and treatment of thyroid disease in pregnant women from Sanming city.

8.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1036486

ABSTRACT

Objective A novel compound based on near-infrared fluorescence (NIRF) probe was prepared to achieve dynamic monitoring of an inflammatory brain edema model in mice and real-time evaluation of therapeutic effects throughin vivo imaging.Methods The NIRF probe IR-783 was chemically linked with clinical brain edema therapeutic drug furosemide (FSM) to obtain the new compound, IR-783-FSM. The ultraviolet fluorescence properties of the compound were evaluated using an ultraviolet spectrophotometer. The uptake of the compound by mouse macrophage cells RAW 264.7 was detected with in vitro cellular experiments. Its cytotoxicity was evaluated through CCK8 assays. A brain edema model was established in BALB/c mice via intraperitoneal injection of lipopolysaccharide (LPS), confirmed by HE staining and dry-wet weight methods for brain tissues. The mice in the brain edema model were divided into control group, IR-783, and IR-783-FSM treatment groups, receiving intraperitoneal injections of PBS, IR-783, and IR-783-FSM, respectively. Real-time in vivo fluorescence imaging was then performed. The mice in each group were euthanized after 10 hours. Ex vivo brain imaging and dry-wet weight measurements were performed to observe the NIRF imaging characteristics and therapeutic effects of IR-783-FSM on brain edema model.Results The newly synthesized compound, IR-783-FSM, retained the excellent near-infrared fluorescence characteristics of IR-783. It could target mouse macrophages with an IC50 of 48.82 µmol/L. A brain edema model could be successfully constructed with intraperitoneal injection of LPS, with significantly higher brain tissue water content compared to the control group (P<0.01). In vivo imaging showed that IR-783-FSM had a significantly stronger fluorescence signal in the brain edema model than IR-783. Compared to the control group, the brain water content was significantly reduced in the 2, 5, and 8 mmol/L IR-783-FSM treatment groups (P<0.01).Conclusion The newly synthesized NIRF probe IR-783-FSM facilitates dynamic monitoring of brain edema and real-time evaluation of therapeutic effects.

9.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1046017

ABSTRACT

Infectious diseases seriously threaten human health. The early detection of the causative organism and antibiotic resistance genes of infection remains a major clinical challenge. Next-generation sequencing has been widely used in diagnosing infectious diseases. Cheaper and faster targeted next-generation sequencing technology is progressively being used in clinical practice. However, the awareness among clinicians about the clinical utility of this technology is limited. The article presents the theoretical background, advantages and disadvantages, clinical applications of targeted next-generation sequencing, and its contrasts with metagenomics next-generation sequencing. It provides a reference for clinicians to select laboratory methods for identifying pathogens in clinical practice.


Subject(s)
Humans , Anti-Bacterial Agents/therapeutic use , High-Throughput Nucleotide Sequencing/methods , Metagenomics/methods , Communicable Diseases
10.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1046340

ABSTRACT

Infectious diseases seriously threaten human health. The early detection of the causative organism and antibiotic resistance genes of infection remains a major clinical challenge. Next-generation sequencing has been widely used in diagnosing infectious diseases. Cheaper and faster targeted next-generation sequencing technology is progressively being used in clinical practice. However, the awareness among clinicians about the clinical utility of this technology is limited. The article presents the theoretical background, advantages and disadvantages, clinical applications of targeted next-generation sequencing, and its contrasts with metagenomics next-generation sequencing. It provides a reference for clinicians to select laboratory methods for identifying pathogens in clinical practice.


Subject(s)
Humans , Anti-Bacterial Agents/therapeutic use , High-Throughput Nucleotide Sequencing/methods , Metagenomics/methods , Communicable Diseases
11.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1028102

ABSTRACT

Objective To analyze the correlation between plasma Pannexin-1(Panx-1)level and no-reflow after percutaneous coronary intervention(PCI)in patients with ST-segment elevation my-ocardial infarction(STEMI).Methods A prospective trial was performed on 218 STEMI patients who underwent PCI in our hospital from January 2019 to December 2021.According to the blood flow classification of myocardial infarction thrombolysis(TIMI)after PCI,they were divided into normal reflow group(110 cases),slow reflow group(69 cases)and no reflow group(39 cases).The plasma Panx-1 level was determined by ELISA,and the levels of P-selectin,activated glyco-protein Ⅱ b/Ⅲ a(aGP Ⅱ b/Ⅲ a)and platelet-leukocyte aggregates(PLA)were determined by flow cytometry.Results Older age,larger ratio of diabetes mellitus,longer time from symptom onset to PCI,higher platelet count and levels of LDL-C,D-dimer,P-selectin,GP Ⅱ b/Ⅲ a,PNA,PM A,PLyA and plasma Panx-1 were observed in the no-reflow group than the normal and slow reflow groups(P<0.05).The plasma Panx-1 level in STEMI patients was positively correlated with P-selectin,GP Ⅱ b/Ⅲ a,PNA,PM A and PLyA(P<0.05,P<0.01).LDL-C ≥3.20 mmol/L and plasma Panx-1>0.88 μg/mL were independent risk factors for no-reflow after PCI in STEMI pa-tients(OR=2.198,95%CI:1.252-3.858,P=0.006;OR=16.849,95%CI:4.481-63.357,P=0.000).The AUC value of Panx-1 was 0.826(95%CI:0.744-0.907,P<0.01)in predicting no re-flux in STEMI patients after PCI.Conclusion The increase of plasma Panx-1 level is closely asso-ciated with the occurrence of no reflow in STEMI patients after PCI,and the protein can be used as a predictive biomarker for the phenomenon.

12.
Heliyon ; 9(12): e23002, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38144322

ABSTRACT

Background: Neurodegenerative retinal diseases such as retinitis pigmentosa are serious disorders that may cause irreversible visual impairment. Ferroptosis is a novel type of programmed cell death, and the involvement of ferroptosis in retinal degeneration is still unclear. This study aimed to investigate the related ferroptosis genes in a mice model of retinal degeneration induced by light damage. Methods: A public dataset of GSE10528 deriving from the Gene Expression Omnibus database was analyzed to identify the differentially expressed genes (DEGs). Gene set enrichment analysis between light damage and control group was conducted. The differentially expressed ferroptosis-related genes (DE-FRGs) were subsequently identified by intersecting the DEGs with a ferroptosis genes dataset retrieved from the FerrDb database. The Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) were further performed using the DE-FRGs. A protein-protein interaction (PPI) network was constructed to identify hub ferroptosis-related genes (HFRGs). The microRNAs (miRNAs)-HFRGs, transcription factors (TFs)-HFRGs networks as well as target drugs potentially interacting with HFRGs were analyzed utilizing bioinformatics algorithms. Results: A total of 932 DEGs were identified between the light damage and control group. Among these, 25 genes were associated with ferroptosis. GO and KEGG analyses revealed that these DE-FRGs were mainly enriched in apoptotic signaling pathway, response to oxidative stress and autophagy, ferroptosis, necroptosis and cytosolic DNA-sensing pathway. Through PPI network analysis, six hub ferroptosis-related genes (Jun, Stat3, Hmox1, Atf3, Hspa5 and Ripk1) were ultimately identified. All of them were upregulated in light damage retinas, as verified by the GSE146176 dataset. Bioinformatics analyses predicated that 116 miRNAs, 23 TFs and several potential therapeutic compounds might interact with the identified HFRGs. Conclusion: Our study may provide novel potential biomarkers, therapeutic targets and new insights into the ferroptosis landscape in retinal neurodegenerative diseases.

13.
Chinese Journal of Trauma ; (12): 906-912, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1026971

ABSTRACT

Objective:To investigate the biomechanical properties of anterior pelvic ring external fixators of two new configurations [iliac crest (IC)+anterior inferior iliac spine (AIIS), anterior superior iliac spine(ASIS)+AIIS] in the treatment of Tile type C1 pelvic fracture.Methods:A 3-dimensional finite element model of Tile type C1 pelvic ring injury (unilateral longitudinal sacral fracture and ipsilateral pubic fracture) was produced. The pelvis was fixed with external fixators of IC, AIIS, combination of IC and AIIS, combination of ASIS and AIIS, and S 1 sacroiliac screw in 5 types of models. In the simulated bipedal standing position and semi-recumbent position, the longitudinal displacement and back rotation angle displacement of the midpoint on the upper surface of S 1 were quantified and compared. Under the simulated left-right compression load state, the lateral displacements of the highest point of the lateral sacral fracture and the highest point of the lateral pubic fracture end were quantified and compared. Under the simulated anterior-posterior shear load state, the backward displacements of the highest point of the lateral sacral fracture end and the highest point of the lateral pubic fracture end were quantified and compared. Results:(1) In the simulated bipedal standing position under the vertical and longitudinal load state, the results of the longitudinal downward displacement of the midpoint on the upper surface of S 1 were consistent with the backward rotation angle displacement, and the order from largest to smallest was IC, AIIS, ASIS+AIIS, IC+AIIS and S 1 sacroiliac screw. The longitudinal downward displacement of IC was significantly larger than that of other models. The longitudinal downward displacement and backward rotation angle displacement of ASIS+AIIS and IC+AIIS were similar, and the latter was smaller. (2) In the simulated semi-recumbent position under the vertical and longitudinal load state, the results of the longitudinal downward displacement and backward rotation angle displacement of the midpoint on the upper surface of S 1 were also consistent, and the order from largest to smallest was IC, AIIS, ASIS+AIIS, IC+AIIS and S 1 sacroiliac screw. (3) Under the simulated left-right compression load state, the results of the lateral displacement of the highest point of the lateral sacral fracture end were consistent with that of the highest point of the lateral pubic fracture end, and the order from largest to smallest was S 1 sacroiliac screw, IC, AIIS, ASIS+AIIS and IC+AIIS. Among them, Among them, The lateral displacement of S 1 sacroiliac screw and IC was larger. The lateral displacement of ASIS+AIIS and IC+AIIS was similar, and the latter was smaller, significantly smaller than that of other models. (4) Under the simulated anterior-posterior shear load state, the results of the backward displacement of the highest point of the lateral sacral fracture end and the highest point of the lateral pubic fracture end were also consistent, and the order from largest to smallest was IC, AIIS, ASIS+AIIS, IC+AIIS and S 1 sacroiliac screw. Among them, the backward displacement of IC and AIIS was larger. The backward displacement of ASIS+AIIS and IC+AIIS was similar, and the latter was smaller. Conclusions:For type C1 pelvic fracture, the biomechanical stabilities of IC+AIIS and ASIS+AIIS are superior to those of IC or AIIS, with ASIS+AIIS being slightly inferior to IC+AIIS. Compared with S 1 sacroiliac screw, IC or AIIS, the lateral stabilities of IC+AIIS and ASIS+AIIS are particularly prominent. The two new external fixator configurations in this study are worthy of clinical application.

14.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1030697

ABSTRACT

The ideological and political content of the laboratory animal science degree course with the basic task of "cultivating morality and cultivating people" is organically integrated into the teaching system of laboratory animal science. It can have a subtle influence on students' thoughts and behaviors. Combined with the curriculum design and professional characteristics of laboratory animal science, this article discussed the ideological and political elements contained in this course, proposed the forms and methods of integrating ideological and political elements into the curriculum design in each chapter. Additionally, the typical cases and characteristic practices of the organic connection of ideological and political education in the teaching system of laboratory animal science were summarized. Practice has proved that integrating the ideological and political elements into the teaching system of laboratory animal science can enhance teacher's awareness and ability of politics, thus effectively improving the compre-hensive quality of students and enhancing the effectiveness of ideological and political education in laboratory animal science.

15.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1030703

ABSTRACT

There are differences in historical and cultural beliefs, development history, and levels of technological development among different countries and regions around the world. However, they have all established corresponding laboratory animal management systems that are suitable for their national conditions. In 2001, the Ministry of Science and Technology, together with six other ministries, jointly issued the administrative licensing system for experimental animals, which was an innovative measure in China's specialized management system for experimental animals.The State Administration for Market Regulation and the National Standards Committee, based on the welfare of experimental animals and the needs of scientific research, have formulated a series of national standards for laboratory animals, and the local experimental animal management institutions, experimental animal quality testing unit and professional training base have also been established, which provide a strong guarantee for the rapid and healthy development of experimental animal science. This paper reviews the development of experimental animal management in Shanghai in the past ten years, reflects the evolution of national experimental animal management in recent years, points out the weak links in the development process, and puts forward suggestions for the innovation and development of experimental animal work.

16.
International Eye Science ; (12): 2059-2064, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-998490

ABSTRACT

AIM: To investigate the refractive status and myopia wearing rate of primary and secondary school students aged 6-18 in Yecheng county, Xinjiang.METHOD: Cross-sectional study. From October 2021 to June 2022, a stratified random sampling method was used to select 81 863 students from 51 primary schools and 30 secondary schools in Yecheng county, Kashgar Prefecture, Xinjiang. Basic data of the students were collected, and non ciliary muscle paralysis optometry was performed to detect naked eye farsightedness and corrected vision with glasses. The refractive status, glasses wearing rate, and full correction rate of students of different ages, genders, and ethnic groups were observed.RESULT: The detection rate of myopia among enrolled students was 13.39%(10958/81863), the wearing rate of glasses was 23.96%(2626/10958), and the full correction rate was 50.57%(1328/2626). The detection rate of myopia shows a certain upward trend with age, and the detection rate of myopia in girls was higher than that in boys(15.75% vs. 10.96%). The detection rates of myopia in Han, Uyghur, and other ethnic students were 68.12%, 12.63%, and 22.42%, respectively.CONCLUSION:The detection rate of myopia and glasses wearing rate were relatively low for students aged 6~18 in Yecheng county, Xinjiang, while the detection rate and glasses wearing rate of myopia among Han students were significantly higher than those of Uyghur and students of other ethnics.

17.
Journal of Stroke ; : 371-377, 2023.
Article in English | WPRIM (Western Pacific) | ID: wpr-1001594

ABSTRACT

Background@#and Purpose Intravenous tenecteplase (TNK) efficacy has not been well demonstrated in acute ischemic stroke (AIS) beyond 4.5 hours after onset. This study aimed to determine the effect of intravenous TNK for AIS within 4.5 to 24 hours of onset. @*Methods@#In this pilot trial, eligible AIS patients with diffusion-weighted imaging (DWI)-fluid attenuated inversion recovery (FLAIR) mismatch were randomly allocated to intravenous TNK (0.25 mg/kg) or standard care within 4.5–24 hours of onset. The primary endpoint was excellent functional outcome at 90 days (modified Rankin Scale [mRS] score of 0–1). The primary safety endpoint was symptomatic intracranial hemorrhage (sICH). @*Results@#Of the randomly assigned 80 patients, the primary endpoint occurred in 52.5% (21/40) of TNK group and 50.0% (20/40) of control group, with no significant difference (unadjusted odds ratio, 1.11; 95% confidence interval 0.46–2.66; P=0.82). More early neurological improvement occurred in TNK group than in control group (11 vs. 3, P=0.03), but no significant differences were found in other secondary endpoints, such as mRS 0–2 at 90 days, shift analysis of mRS at 90 days, and change in National Institutes of Health Stroke Scale score at 24 hours and 7 days. There were no cases of sICH in this trial; however, asymptomatic intracranial hemorrhage occurred in 3 of the 40 patients (7.5%) in the TNK group. @*Conclusion@#This phase 2, randomized, multicenter study suggests that intravenous TNK within 4.5–24 hours of onset may be safe and feasible in AIS patients with a DWI-FLAIR mismatch.

18.
International Eye Science ; (12): 471-476, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-964251

ABSTRACT

AIM: To investigate the differences of myopia and ocular biological parameters of primary and middle school students in Urumqi.METHODS: A cross-sectional survey. A total of 2 495 primary and middle school students aged 7 to 18 from 4 schools in Urumqi were selected by judgemental sampling from September 2021 to November 2021 for relevant eye examination. The differences of ocular biological parameters and refractive status of students of different ages, genders and nationalities were compared, and the correlation between spherical equivalent(SE)and ocular biological parameters was analyzed.RESULTS: The detection rate of poor vision among the students was 80.36%, the detection rate of myopia was 55.91%, and the detection rate of astigmatism was 42.96%, among which the detection rate of low myopia was 63.80%, the detection rate of moderate myopia was 27.60%, and the detection rate of high myopia was 8.60%. There were significant differences in the detection rate of poor vision, myopia, astigmatism, SE and some ocular biological parameters among students of different ages and nationalities(all P<0.05). Among them, the detection rate of myopia, astigmatism and poor vision among Uygur and Kazakh ethnic groups was significantly lower than that of Han. The detection rate of poor vision and myopia among boys was lower than that among girls, while the detection rate of astigmatism was higher than that of girls. Spearman correlation analysis showed that axis length of eye, axial length to axial ratio, anterior chamber depth, and pupil diameter were negatively correlated with SE(rs=-0.664, -0.724, -0.320, -0.086, all P<0.001), and lens thickness was positively correlated with SE(rs=0.147, P<0.001).CONCLUSION: The prevalence of myopia among primary and secondary school students in Urumqi is high, and there are differences in the distribution of ocular biological parameters among children and adolescents of different ages and ethnicities.

19.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-970878

ABSTRACT

OBJECTIVE@#To explore the genetic basis for a child with mental retardation.@*METHODS@#Whole exome sequencing was carried out for the child. Candidate variant was screened based on his clinical features and verified by Sanger sequencing.@*RESULTS@#The child was found to harbor a c.995_1002delAGACAAAA(p.Asp332AlafsTer84) frameshift variant in the SYNGAP1 gene. Bioinformatic analysis suggested it to be pathogenic. The same variant was not detected in either parent.@*CONCLUSION@#The c.995_1002delAGACAAAA(p.Asp332AlafsTer84) frameshift variant of the SYNGAP1 gene probably underlay the mental retardation in this child. Above finding has expanded the spectrum of SYNGAP1 gene variants and provided a basis for the diagnosis and treatment for this child.


Subject(s)
Child , Humans , Intellectual Disability/genetics , Frameshift Mutation , High-Throughput Nucleotide Sequencing , Computational Biology , Heterozygote , Mutation , ras GTPase-Activating Proteins/genetics
20.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-973752

ABSTRACT

ObjectiveBased on ultra performance liquid chromatography-quadrupole-time-of-flight mass spectrometry(UPLC-Q-TOF-MSE) technique, we identified qualitatively the metabolites of aristolochic acid(AAs) in rat in order to analyze the metabolic differences between water extract of Aristolochiae fructus(AFE) and Aristolochic acid Ⅰ(AAⅠ). MethodSD rats were selected and administered AFE(110 g·kg-1·d-1) or AAⅠ(5 mg·kg-1·d-1) by oral for 5 days, respectively. Serum, urine and feces were collected after administration. Through sample pretreatment, ACQUITY UPLC BEH C18 column(2.1 mm×100 mm, 1.7 μm) was used with the mobile phase of 0.01% formic acid methanol(A)-0.01% formic acid water(B, containing 5 mmol·L-1 ammonium acetate) for gradient elution(0-1 min, 10%B; 1-7 min, 10%-75%B; 7-7.2 min, 75%-95%B; 7.2-10.2 min, 95%B; 10.2-10.3 min, 95%-10%B; 10.3-12 min, 10%B) at a flow rate of 0.3 mL·min-1. Positive ion mode of electrospray ionization(ESI+) was performed in the scanning range of m/z 100-1 200. In combination with UNIFI 1.9.4.053 system, the Pathway-MSE was used to qualitatively analyze and identify the AAs prototype and related metabolites in biological samples(serum, urine and feces), and to compare the similarities and differences of metabolites in rats in the subacute toxicity test between AFE group and AAⅠ group. ResultCompared with AAⅠ group, 6, 10, 13 common metabolites and 14, 20, 30 unique metabolites were identified in biological samples(serum, urine and feces) of AFE group, respectively. Moreover, the main AAs components always followed the metabolic processes of demethylation, nitrate reduction and conjugation. Compared with common metabolites in AAⅠ group, prototype components of AAⅠ in serum and most metabolic derivatives of AAⅠ[AAⅠa, aristolochic lactam Ⅰ(ALⅠ)a, 7-OHALⅠ and its conjugated derivatives] in biological samples were significantly increased in AFE group(P<0.05, P<0.01), except that the metabolic amount of ALⅠ in feces of AFE group was remarkably lowed than that of AAⅠ group(P<0.01). In addition, a variety of special ALⅠ efflux derivatives were also identified in the urine and feces of the AFE group. ConclusionAlthough major AAs components in AFE all show similar metabolic rules as AAⅠ components in vivo, the coexistence of multiple AAs components in Aristolochiae Fructus may affect the metabolism of AAⅠ, and achieve the attenuating effect by increasing the metabolic effection of AAⅠ and ALⅠ.

SELECTION OF CITATIONS