Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.229
Filter
1.
BMC Cardiovasc Disord ; 24(1): 508, 2024 Sep 23.
Article in English | MEDLINE | ID: mdl-39313838

ABSTRACT

BACKGROUNDS: The prognosis of the triglyceride-glucose (TyG) index, a validated surrogate marker for insulin resistance, in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains unknown. METHODS: This study consecutively enrolled patients diagnosed with severe AS who underwent TAVR in a Chinese tertiary hospital from March 2013 to September 2023. Participants were stratified based on the TyG index cut-off value. Cox proportional hazards regression models were utilized to explore the association between the TyG index and all-cause mortality, including an assessment of interactions between the TyG index and various covariates on mortality outcomes. RESULTS: Among 1045 patients (mean age 74.7 years, 58.2% male), there was 134 all-cause mortality, resulting in a crude mortality rate of 64.3 per 1000 person-years. Adjusting for age, sex, body mass index, smoking, hypertension, diabetes mellitus, bicuspid aortic valve, atrial fibrillation, Society of Thoracic Surgeons (STS) score, and left ventricular ejection fraction, a per-unit increase in the TyG index was associated with a 41% higher all-cause mortality risk (HR 1.41, 95% CI 1.03-1.93, p = 0.030). Notably, the relationship between the TyG index and all-cause mortality was significantly modified by age (pinteraction = 0.027), sex (pinteraction = 0.007), hypertension (pinteraction = 0.030), and STS score (pinteraction = 0.002). CONCLUSIONS: A higher TyG index is significantly associated with an increased risk of all-cause mortality in AS patients after TAVR. These results underscore the importance of considering the TyG index in the prognostic evaluation of AS patients following TAVR.


Subject(s)
Aortic Valve Stenosis , Biomarkers , Blood Glucose , Cause of Death , Transcatheter Aortic Valve Replacement , Triglycerides , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/physiopathology , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Aged , Risk Assessment , Blood Glucose/metabolism , Aged, 80 and over , Biomarkers/blood , Triglycerides/blood , Treatment Outcome , Time Factors , Retrospective Studies , Severity of Illness Index , China/epidemiology , Predictive Value of Tests , Insulin Resistance
2.
Article in English | MEDLINE | ID: mdl-39322554

ABSTRACT

PURPOSE: This study aimed to compare the clinical outcomes of isolated surgical aortic valve replacement (SAVR) and transfemoral (TF)-transcatheter aortic valve replacement (TAVR) in low-risk aortic stenosis (AS) patients. METHODS: A total of 696 low-risk (Society of Thoracic Surgeons score <4%) AS patients underwent isolated SAVR or TF-TAVR at five centers. After 1:1 propensity score matching, 159 pairs were identified. Early and follow-up events, including cardiac mortality and major adverse cardiac and cerebrovascular events (MACCE: all-cause mortality, heart failure admission, reoperation, prosthetic valve endocarditis, and stroke), were compared. RESULTS: Baseline characteristics are similar between the matched groups. There were no 30-day cardiac mortalities in either group. All-cause mortality and MACCE at 30 days did not differ. During 5-year follow-up (median 3.1 [range 0-7.2] years), the incidence of cardiac mortality (1.3% vs. 18.9%; adjusted hazard ratio [aHR], 8.89; 95% confidence interval [CI], 2.68-29.53; P <0.001), all-cause mortality (4.2% vs. 33.9%; aHR, 8.56; 95% CI, 3.41-21.45; P <0.001), and MACCE (25.1% vs. 47.0%; aHR, 2.36; 95% CI, 1.54-3.63; P <0.001) were lower in the SAVR group than in the TAVR group. CONCLUSIONS: Isolated SAVR demonstrated better outcomes in low-risk AS patients. TAVR in this subset should be chosen carefully.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Male , Female , Time Factors , Aged , Treatment Outcome , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Risk Assessment , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Retrospective Studies , Postoperative Complications/mortality , Postoperative Complications/etiology , Aged, 80 and over , Propensity Score , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Kaplan-Meier Estimate , Middle Aged
3.
Biomark Med ; 18(15-16): 675-683, 2024 Aug 17.
Article in English | MEDLINE | ID: mdl-39263804

ABSTRACT

Aim: Investigating the impact of nutritional and inflammatory status, assessed by the Naples-Prognostic-Score (NPS), on postoperative mortality in 173 older adults undergoing surgical aortic valve replacement(SAVR) for aortic stenosis(AS).Methods: Retrospective study calculating NPS from neutrophils/lymphocytes, lymphocytes/monocytes, total cholesterol and serum albumin.Results: Mean age was 69.39 ± 6.153 with 45.1% females. The post-operative mortality was 23.7% over a follow-up period of 50 ± 31 months. The 1-month mortality rate is 2.89%. High NPS significantly associated with increased mortality; multivariate logistic regression confirmed its independence (odds-ratio:3.494, 95% confidence-interval:1.555-7.849, p = 0.002). NPS cutoff of 2 showed 73.2% sensitivity, 56.8% specificity and area-under-the-curve of 0.758 for predicting all-cause mortality. Kaplan-Meier analysis supported lower NPS correlating with better survival.Conclusion: NPS independently predicts postoperative mortality in SAVR patients.


[Box: see text].


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Humans , Female , Male , Aged , Retrospective Studies , Prognosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Middle Aged , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , ROC Curve
4.
JACC Cardiovasc Interv ; 17(17): 2023-2037, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39260960

ABSTRACT

BACKGROUND: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited. OBJECTIVES: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes. METHODS: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed. Patients were stratified into 3 groups: group 1 (n = 125), with no THV underexpansion or eccentricity; group 2 (n = 69), with underexpansion or eccentricity; and group 3 (n = 35), with both. Calcium distribution was assessed using CT, and its associations with clinical outcomes, including all-cause mortality at 3 years and leaflet thrombosis at 30 days, were determined. A subgroup analysis of patients with type 1 BAVs was conducted. RESULTS: Group 3 exhibited higher rates of all-cause mortality than the other groups, along with the highest risk for hypoattenuated leaflet thickening at 30 days. Multivariate analysis identified annular and left ventricular outflow tract calcification as independent predictors of all-cause mortality and hypoattenuated leaflet thickening. In patients with type 1 BAVs, excessive calcification at the raphe and opposite leaflet were associated with all-cause mortality at 3 years. CONCLUSIONS: THV deformation post-TAVR was significantly linked to all-cause mortality in patients with BAVs. Annular and left ventricular outflow tract calcification correlated with increased risks for all-cause mortality and leaflet thrombosis. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Calcinosis , Heart Valve Diseases , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Bicuspid Aortic Valve Disease/diagnostic imaging , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Treatment Outcome , Risk Factors , Time Factors , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Balloon Valvuloplasty/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality , Retrospective Studies , Risk Assessment , Thrombosis/diagnostic imaging , Thrombosis/etiology , Multidetector Computed Tomography , Predictive Value of Tests
5.
JACC Cardiovasc Interv ; 17(17): 2054-2066, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39260962

ABSTRACT

BACKGROUND: Fluid overload (FO) subjects patients with severe aortic stenosis (AS) to increased risk for heart failure and death after valve replacement and can be objectively quantified using bioimpedance spectroscopy (BIS). OBJECTIVES: The authors hypothesized that in AS patients with concomitant FO, BIS-guided decongestion could improve prognosis and quality of life following transcatheter aortic valve replacement (TAVR). METHODS: This randomized, controlled trial enrolled 232 patients with severe AS scheduled for TAVR. FO was defined using a portable whole-body BIS device according to previously established cutoffs (≥1.0 L and/or ≥7%). Patients with FO (n = 111) were randomly assigned 1:1 to receive BIS-guided decongestion (n = 55) or decongestion by clinical judgment alone (n = 56) following TAVR. Patients without FO (n = 121) served as a control cohort. The primary endpoint was the composite of hospitalization for heart failure and/or all-cause death at 12 months. The secondary endpoint was the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire. RESULTS: The occurrence of the primary endpoint at 12 months was significantly lower in the BIS-guided vs the non-BIS-guided decongestion group (7/55 [12.7%, all deaths] vs 18/56 [32.1%, 9 hospitalizations for heart failure and 9 deaths]; HR: 0.36; 95% CI: 0.15-0.87; absolute risk reduction = -19.4%). Outcomes in the BIS-guided decongestion group were identical to the euvolemic control group (log-rank test, P = 0.7). BIS-guided decongestion was also associated with a higher increase in the Kansas City Cardiomyopathy Questionnaire score from baseline compared to non-BIS-guided decongestion (P = 0.001). CONCLUSIONS: In patients with severe AS and concomitant FO, quantitatively guided decongestive treatment and associated intensified management post-TAVR was associated with improved outcomes and quality of life compared to decongestion by clinical judgment alone. (Management of Fluid Overload in Patients Scheduled for Transcatheter Aortic Valve Replacement [EASE-TAVR]; NCT04556123).


Subject(s)
Aortic Valve Stenosis , Heart Failure , Quality of Life , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Time Factors , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/diagnosis , Dielectric Spectroscopy , Water-Electrolyte Imbalance/physiopathology , Water-Electrolyte Imbalance/therapy , Water-Electrolyte Imbalance/diagnosis , Water-Electrolyte Imbalance/mortality , Water-Electrolyte Imbalance/etiology , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Predictive Value of Tests , Recovery of Function , Prospective Studies
6.
JACC Cardiovasc Interv ; 17(17): 2011-2022, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39260959

ABSTRACT

BACKGROUND: Asymmetrical expansion of transcatheter heart valves (THVs), manifesting as stent frame deformation, is an occasional fluoroscopic finding in transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to investigate the impact of asymmetrical expansion of balloon-expandable THVs on hemodynamic valve performance and clinical outcomes. METHODS: In a prospective registry, TAVR asymmetry index was measured using freeze-frame fluoroscopic images and was defined as the ratio of THV heights: [(longer height/shorter height) - 1] × 100. THV hemodynamic performance was measured using echocardiography before hospital discharge. Impaired hemodynamic valve performance was defined as a mean residual THV gradient ≥20 mm Hg and/or moderate or greater paravalvular regurgitation. RESULTS: Among 1,216 patients undergoing transfemoral TAVR for native severe aortic valve stenosis with contemporary balloon-expandable THVs between February 2014 and June 2022, asymmetry index was an excellent predictor of impaired hemodynamic valve performance (area under the receiver-operating characteristic curve: 0.88; 95% CI: 0.84-0.92; P < 0.001). The optimal asymmetry index threshold for predicting impaired THV performance was >5.5% (sensitivity 77%, specificity 86%) and occurred in 17% of patients. Higher asymmetry index, as a continuous variable, was associated with impaired hemodynamic valve performance independent of total aortic valve calcium, bicuspid anatomy, balloon-expandable valve prosthesis type or size, and Society of Thoracic Surgeons Predicted Risk of Mortality score (OR: 1.37; 95% CI: 1.29-1.46; P < 0.001). High TAVR asymmetry index was not associated with all-cause mortality during a median of 376 days of follow-up (HR: 1.00; 95% CI: 0.71-1.41; P = 0.989). CONCLUSIONS: Asymmetrical expansion of balloon-expandable THVs was associated with impaired hemodynamic valve performance but not with clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Aged , Risk Factors , Time Factors , Prospective Studies , Severity of Illness Index , Recovery of Function , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology
7.
JACC Cardiovasc Interv ; 17(17): 2041-2051, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39177555

ABSTRACT

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.


Subject(s)
Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Registries , Humans , Male , Female , Time Factors , Treatment Outcome , Aged , Risk Factors , United States , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Risk Assessment , Hemodynamics , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Recovery of Function , Retrospective Studies , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality
9.
Arch Cardiovasc Dis ; 117(8-9): 461-469, 2024.
Article in English | MEDLINE | ID: mdl-39153878

ABSTRACT

BACKGROUND: Transthyretin amyloid cardiomyopathy (ATTR-CM) can manifest as rhythm disorders, heart failure, but also valvular degeneration. Despite aortic stenosis (AS) being prevalent among the elderly, data on ATTR-CM prevalence and outcome in patients with AS undergoing transaortic valve implantation (TAVI) remain scarce. AIM: To determine ATTR-CM prevalence and evaluate 1-year survival in patients undergoing TAVI. METHODS: Between December 2020 and September 2021, 100 consecutive patients underwent TAVI and were screened prospectively for ATTR-CM using bone scintigraphy (BS). Monoclonal gammopathy was ruled out in case of cardiac uptake on BS. All patients were followed prospectively for 1year after TAVI. RESULTS: The proportion of patients aged≥75years or with a EuroSCORE II>8% and possible femoral access was 99%. The abnormal cardiac uptake rate on BS was 7% (95% confidence interval: 2-12%); 86% of these patients were male. The RAISE (remodelling, age, injury, system and electrical) score, indicative of ATTR-CM risk, was higher in case of positive BS (P=0.04). Patients with positive BS were older and exhibited wider QRS complexes on electrocardiography (P=0.003), a higher frequency of reduced LVEF (57% vs. 17%), impaired basal LV strain (P=0.02) and a lower voltage/mass ratio (P=0.01). History of pacemaker implantation before TAVI was higher in the positive BS group (P=0.0004) and remained the only statistically significant factor after adjustment using the Holm-Bonferroni method. One-year survival of patients with positive BS did not differ from that of patients with isolated AS. CONCLUSIONS: Prevalence of ATTR-CM in patients treated with TAVI, underscoring the need for continued surveillance for potential development of ATTR-CM after TAVI. Caution is warranted regarding the 1-year survival because of the lack of study power. Further investigations are needed to define long-term prognosis of AS with ATTR-CM.


Subject(s)
Amyloid Neuropathies, Familial , Aortic Valve Stenosis , Cardiomyopathies , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/epidemiology , Male , Female , Prevalence , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Time Factors , Treatment Outcome , Amyloid Neuropathies, Familial/mortality , Amyloid Neuropathies, Familial/epidemiology , Amyloid Neuropathies, Familial/diagnostic imaging , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/surgery , Amyloid Neuropathies, Familial/diagnosis , Risk Factors , Prospective Studies , Cardiomyopathies/mortality , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/physiopathology , Cardiomyopathies/epidemiology , Risk Assessment , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology
10.
J Am Heart Assoc ; 13(15): e034298, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39101495

ABSTRACT

BACKGROUND: Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use. METHODS AND RESULTS: The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke. CONCLUSIONS: CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.


Subject(s)
Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Male , Female , Stroke/prevention & control , Stroke/epidemiology , Stroke/etiology , Aged, 80 and over , Aged , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , United States/epidemiology , Embolic Protection Devices , Risk Assessment/methods , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Treatment Outcome , Patient Readmission/statistics & numerical data , Retrospective Studies , Databases, Factual , Incidence , Time Factors
11.
Cardiovasc Diabetol ; 23(1): 312, 2024 Aug 24.
Article in English | MEDLINE | ID: mdl-39182080

ABSTRACT

BACKGROUND: The triglyceride glucose (TyG) index, as a reliable marker of insulin resistance, is associated with the incidence and poor prognosis of various cardiovascular diseases. However, the relationship between the TyG index and clinical outcomes in patients with severe aortic stenosis (AS) who underwent transcatheter aortic valve replacement (TAVR) remains unclear. METHODS: This study consecutively enrolled 1569 patients with AS underwent TAVR at West China Hospital of Sichuan University between April 2014 and August 2023. The outcomes of interest included all-cause mortality, cardiovascular mortality, and major adverse cardiovascular events (MACE). Multivariate adjusted Cox regression and restricted cubic splines (RCS) regression analyses were used to assess the associations between the TyG index and the clinical outcomes. The incremental prognostic value of the TyG index was further assessed by the time-dependent Harrell's C-index, integrated discrimination improvement (IDI) and the net reclassification improvement (NRI). RESULTS: During a median follow-up of 1.09 years, there were 146, 70, and 196 patients experienced all-cause death, cardiovascular death, and MACE, respectively. After fully adjusting for confounders, a per-unit increase of TyG index was associated with a 441% (adjusted HR: 5.41, 95% CI: 4.01-7.32), 385% (adjusted HR: 4.85, 95% CI: 3.16-7.43), and 347% (adjusted HR: 4.47, 95% CI: 3.42-5.85) higher risk of all-cause mortality, cardiovascular mortality and MACE, respectively. The RCS regression analyses revealed a linear association between TyG index and endpoints (all P for non-linearity > 0.05) with 8.40 as the optimal binary cutoff point. Furthermore, adding TyG index to the basic risk model provided a significant incremental value in predicting poor prognosis (Time-dependent Harrell's C-index increased for all the endpoints; All-cause mortality, IDI: 0.11, P < 0.001; NRI: 0.32, P < 0.001; Cardiovascular mortality, IDI: 0.043, P < 0.001; NRI: 0.37, P < 0.001; MACE, IDI: 0.092, P < 0.001; NRI: 0.32, P < 0.001). CONCLUSIONS: In patients with severe AS receiving TAVR, there was a positive linear relationship between TyG index and poor prognosis, with 8.4 as the optimal bivariate cutoff value. Our findings suggest TyG index holds potential value for risk stratification and guiding therapeutic decisions in patients after TAVR.


Subject(s)
Aortic Valve Stenosis , Biomarkers , Blood Glucose , Predictive Value of Tests , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Triglycerides , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Aged , Risk Assessment , Risk Factors , Aged, 80 and over , Time Factors , Treatment Outcome , China/epidemiology , Biomarkers/blood , Blood Glucose/metabolism , Triglycerides/blood , Cause of Death , Insulin Resistance
12.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39142756

ABSTRACT

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Subject(s)
Aortic Valve Stenosis , Ischemic Attack, Transient , Severity of Illness Index , Stroke , Transcatheter Aortic Valve Replacement , Humans , Male , Risk Factors , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Incidence , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Time Factors , Risk Assessment , Ischemic Attack, Transient/etiology , Ischemic Attack, Transient/mortality , Ischemic Attack, Transient/epidemiology , Treatment Outcome , Stroke/mortality , Stroke/etiology , Stroke/epidemiology , Delirium/epidemiology , Delirium/etiology , Delirium/diagnosis , Delirium/mortality , Databases, Factual , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging
13.
JACC Cardiovasc Interv ; 17(16): 1905-1915, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197989

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Health Status , Mitral Valve , Registries , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Female , Male , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/surgery , Aged , Time Factors , Aged, 80 and over , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , United States , Risk Assessment , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Severity of Illness Index , Recovery of Function , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality
14.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197990

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Hospital Mortality , Prosthesis Design , Recovery of Function , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Aged , United States/epidemiology , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Risk Assessment , Prevalence , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Retrospective Studies , Centers for Medicare and Medicaid Services, U.S. , Hemodynamics
15.
J Am Heart Assoc ; 13(17): e032901, 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39190595

ABSTRACT

BACKGROUND: Cerebrovascular events remain one of the most devastating complications of transcatheter aortic valve implantation (TAVI). Data from real-world contemporary cohorts on longitudinal trends and outcomes remain limited. The aim of this study was to assess incidence, temporal trends, predictors, and outcomes of cerebrovascular events following transfemoral TAVI. METHODS AND RESULTS: The CENTER2 (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves 2) study includes patients undergoing TAVI between 2007 and 2022. The database contains pooled patient-level data from 10 clinical studies. A total of 24 305 patients underwent transfemoral TAVI (mean age 81.5±6.7 years, 56% women, median Society of Thoracic Surgeon Predicted Risk of Mortality 4.9% [3.1%-8.5%]). Of these patients, 2.2% (n=534) experienced stroke in the first 30 days after TAVI, and 40 (0.4%) had a transient ischemic attack. Stroke rates remained stable during the treatment period (2007-2010: 2.1%, 2011-2014: 2.5%, 2015-2018: 2.1%, 2019-2022: 2.1%; Ptrend=0.28). Moreover, 30-day cerebrovascular event rates were similar across Society of Thoracic Surgeon Predicted Risk of Mortality risk categories: 2.1% in low-risk, 2.6% in intermediate-risk, and 2.5% in high-risk patients (P=0.21). Mortality was higher in patients with 30-day stroke than without at 30 days (20.3% versus 4.7%; odds ratio, 5.1 [95% CI, 4.1-6.5]; P<0.001) and at 1 year (44.1% versus 15.0%; hazard ratio, 3.5 [95% CI, 3.0-4.2]; P<0.001). One-year mortality rates for stroke did not decline over time (2007-2010: 46.9%, 2011-2014: 46.0%, 2015-2018: 43.0%, 2019-2022: 39.1%; Ptrend=0.32). At 1 year, 7.0% of patients undergoing TAVI had a stroke. CONCLUSIONS: In 24 305 patients who underwent transfemoral TAVI, 30-day cerebrovascular event incidence remained ≈ 2.2% between 2007 and 2022. Thirty-day stroke rates were similar throughout Society of Thoracic Surgeon Predicted Risk of Mortality risk categories. Mortality rates after stroke remain high. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03588247.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Femoral Artery , Incidence , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/etiology , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Postoperative Complications/etiology , Risk Assessment/methods , Risk Factors , Stroke/epidemiology , Stroke/etiology , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
16.
Am Heart J ; 277: 27-38, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39128658

ABSTRACT

BACKGROUND: Previous studies on the impact of sex differences after transcatheter aortic valve replacement (TAVR) have shown conflicting results. The aim was to analyze the risk of long-term mortality, heart failure hospitalization, myocardial infarction, stroke, bleeding and aortic valve reintervention in females versus males after TAVR. METHODS: This nationwide, population-based cohort study included all patients who underwent TAVR in Sweden between 2008 and 2022 from the SWEDEHEART register. Additional baseline and outcome data were gathered from other national health data registers. Regression standardization was used to adjust for differences between the sexes. RESULTS: Of 10,475 patients, 4,886 (47%) were female and 5,589 (53%) were male. The mean age was 81 years. The cumulative incidence of mortality at 1, 5, and 10 years was 8% vs. 10%, 38% vs. 45%, and 75% vs. 82% for females and males, respectively. After regression standardization, the risk of all-cause mortality was lower for females (absolute difference at 10 years of 6.4%, 95% confidence interval [CI] 4.4%-8.4%). The mean follow up was 3.1 years (maximum 14.1 years). Females also had a lower risk of major bleeding than males (absolute survival difference at 10 years of 4.0%, 95% CI 1.9%-6.2%), but there was no difference in the risk of heart failure, myocardial infarction, stroke, or reintervention between the sexes. CONCLUSIONS: Females had a higher survival rate and a lower bleeding risk than males after TAVR. Sex-specific factors are important to consider in the management of patients after TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Female , Male , Sweden/epidemiology , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Sex Factors , Aged , Postoperative Complications/epidemiology , Stroke/epidemiology , Stroke/etiology , Registries , Myocardial Infarction/epidemiology , Risk Factors , Heart Failure/epidemiology , Incidence , Time Factors , Survival Rate/trends , Follow-Up Studies , Reoperation/statistics & numerical data
17.
Open Heart ; 11(2)2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39043607

ABSTRACT

OBJECTIVE: To compare long-term cardiovascular (CV) outcomes between men and women with aortic stenosis (AS) undergoing aortic valve replacement (AVR) by the type of valve implant. METHODS: The study population consisted of 14 123 non-selected patients with AS undergoing first-time AVR and included in the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies (SWEDEHEART) registry during 2008-2016. Comparisons were made between men and women and type of valve implant (ie, surgical implantation with a mechanical (mSAVR) (n=1 966) or biological valve (bioSAVR) (n=9 801)) or by a transcatheter approach (TAVR) (n=2 356). Outcomes included all-cause mortality, ischaemic stroke, major bleeding, thromboembolic events, heart failure and myocardial infarction, continuously adjusted for significant comorbidities and medical treatment. RESULTS: In the mSAVR cohort, there were no significant sex differences in any CV events. In the bioSAVR cohort, a higher risk of death (HR: 1.14; 95% CI: 1.04 to 1.26, p=0.007) and major bleeding (HR: 1.41; 95% CI: 1.18 to 1.69, p<0.001) was observed in men. In the TAVR cohort, men suffered a higher risk of death (HR: 1.24; 95% CI: 1.07 to 1.45, p=0.005), major bleeding (HR: 1.35; 95% CI: 1.00 to 1.82, p=0.022) and thromboembolism (HR: 1.35, 95% CI: 1.00 to 1.82, p=0.047). CONCLUSION: No significant long-term difference in CV events was noted between men and women undergoing AVR with a mechanical aortic valve. In both the bioSAVR and TAVR cohort, mortality was higher in men who also had an increased incidence of several other CV events.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Registries , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Sweden/epidemiology , Aged , Sex Factors , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Heart Valve Prosthesis , Time Factors , Follow-Up Studies , Prognosis , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Incidence , Survival Rate/trends , Retrospective Studies
18.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048253

ABSTRACT

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Bioprosthesis , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Risk Factors , Prospective Studies , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Risk Assessment , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/physiopathology , United States/epidemiology , Severity of Illness Index , Postoperative Complications/mortality , Recovery of Function , Aged, 80 and over , Middle Aged , Heart Valve Diseases/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality
19.
JACC Cardiovasc Interv ; 17(14): 1680-1690, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048255

ABSTRACT

BACKGROUND: Thromboembolic events, particularly strokes, remain a major complication of transcatheter aortic valve replacement (TAVR). Embolic protection devices have failed to show significant clinical benefit in large randomized clinical trials. Aortic wall thrombus (AWT) is often observed on multidetector computed tomography during TAVR work-up, but its prognostic significance is uncertain. OBJECTIVES: This study sought to evaluate the association between the presence of AWT and the incidence of thromboembolic outcomes in patients undergoing transfemoral (TF) TAVR for severe aortic stenosis. METHODS: This was a prospective cohort study of consecutive patients who underwent TF TAVR for severe aortic stenosis between January 2011 and April 2022. A dedicated scale (range: 0-10) was qualitatively used to assess AWT. The primary outcome was a composite of procedural thromboembolic events defined as ischemic stroke, blue toe syndrome, bowel ischemia, or other solid organ infarction. The secondary endpoints were ischemic strokes and procedural death. RESULTS: Of the 641 patients included, severe AWT (score ≥8) was identified in 73 (11.4%). The presence of severe AWT was strongly associated with an increase in the primary outcome (OR: 8.48; 95% CI: 3.36-21.40; P < 0.001). This relationship persisted following multivariable analysis, which adjusted for comorbidities and procedural characteristics. The presence of severe AWT was also found to be associated with an increased incidence of stroke and procedural death (OR: 5.66; 95% CI: 2.00-15.30; P = 0.002 and OR: 4.66; 95% CI: 1.80-11.30; P = 0.002, respectively). CONCLUSIONS: The presence of severe AWT on preprocedural multidetector computed tomography is strongly associated with thromboembolic complications including stroke and mortality after TF TAVR.


Subject(s)
Aortic Valve Stenosis , Femoral Artery , Severity of Illness Index , Thromboembolism , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Female , Male , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Prospective Studies , Risk Factors , Aged , Femoral Artery/diagnostic imaging , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/mortality , Thrombosis/epidemiology , Treatment Outcome , Thromboembolism/etiology , Thromboembolism/diagnostic imaging , Thromboembolism/mortality , Thromboembolism/prevention & control , Incidence , Risk Assessment , Time Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Multidetector Computed Tomography , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Punctures
20.
Clin Cardiol ; 47(8): e24324, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39054901

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been increasingly used in patients with severe aortic stenosis (AS). Since coronary artery disease (CAD) is common among these patients, it is crucial to choose the best method and timing of revascularization. This study aims to compare different timing strategies of percutaneous coronary intervention (PCI) in patients with severe AS undergoing TAVI to clarify whether PCI timing affects the patients' outcomes or not. METHODS: A frequentist network meta-analysis was conducted comparing three different revascularization strategies in patients with CAD undergoing TAVI. The 30-day all-cause mortality, in-hospital mortality, all-cause mortality at 1 year, 30-day rates of myocardial infarction (MI), stroke, and major bleeding, and the need for pacemaker implantation at 6 months were analyzed in this study. RESULTS: Our meta-analysis revealed that PCI during TAVI had higher 30-day mortality (RR = 2.46, 95% CI = 1.40-4.32) and in-hospital mortality (RR = 1.70, 95% CI = [1.08-2.69]) compared to no PCI. Post-TAVI PCI was associated with higher 1-year mortality compared to other strategies. While no significant differences in major bleeding or stroke were observed, PCI during TAVI versus no PCI (RR = 3.63, 95% CI = 1.27-10.43) showed a higher rate of 30-day MI. CONCLUSION: Our findings suggest that among patients with severe AS and CAD undergoing TAVI, PCI concomitantly with TAVI seems to be associated with worse 30-day outcomes compared with no PCI. PCI after TAVI demonstrated an increased risk of 1-year mortality compared to alternative strategies. Choosing a timing strategy should be individualized based on patient characteristics and procedural considerations.


Subject(s)
Aortic Valve Stenosis , Network Meta-Analysis , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Hospital Mortality , Treatment Outcome , Time Factors , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Risk Assessment/methods , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL