Aust J Gen Pract ; 53(7): 430-435, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38957055

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are a core component in the management of heart rhythm disorders. The complexity of devices, the information gathered and therapy delivered by CIEDs continues to advance at pace. OBJECTIVE: The aim of this paper is to provide an update on advances in CIED technology and how this applies to managing patients with CIEDs in general practice. DISCUSSION: In recent years, there have been notable advances in CIED technology. These include widespread magnetic resonance imaging compatibility and automated algorithms to assist in the clinical management of patients. There is the ability for clinicians and pacemaker clinics to monitor devices remotely, avoiding in-clinic visits. Options are now available for leadless pacemakers and subcutaneous defibrillators as an alternative to indwelling leads and associated infection and vascular issues. Techniques have been developed to allow leads to capture the native conduction system, providing physiological cardiac activation (conduction system pacing) for treatment and prevention of heart failure.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology
4.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
6.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38823116

ABSTRACT

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Subject(s)
Bundle of His , Humans , Bundle of His/physiopathology , Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Electric Countershock/methods , Heart Ventricles/physiopathology , Models, Cardiovascular
7.
Adv Exp Med Biol ; 1441: 1023-1031, 2024.
Article in English | MEDLINE | ID: mdl-38884767

ABSTRACT

The electrocardiogram (ECG) is one of the cornerstones of diagnostic investigations in pediatric or adult cardiology. The standard ECG includes 12 leads; there are 6 leads that are derived from electrodes from the arms and legs (Einthoven and Goldberger leads) and 6 precordial leads (Wilson leads).


Subject(s)
Arrhythmias, Cardiac , Electrocardiography , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Child , Adult
8.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38848447

ABSTRACT

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Subject(s)
Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/surgery , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Electroporation/trends , Electroporation/methods , Treatment Outcome , Forecasting , Catheter Ablation/trends , Catheter Ablation/methods , Ablation Techniques/trends , Cardiac Catheters , Animals
13.
Pacing Clin Electrophysiol ; 47(6): 789-801, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38712484

ABSTRACT

The rapid growth in computational power, sensor technology, and wearable devices has provided a solid foundation for all aspects of cardiac arrhythmia care. Artificial intelligence (AI) has been instrumental in bringing about significant changes in the prevention, risk assessment, diagnosis, and treatment of arrhythmia. This review examines the current state of AI in the diagnosis and treatment of atrial fibrillation, supraventricular arrhythmia, ventricular arrhythmia, hereditary channelopathies, and cardiac pacing. Furthermore, ChatGPT, which has gained attention recently, is addressed in this paper along with its potential applications in the field of arrhythmia. Additionally, the accuracy of arrhythmia diagnosis can be improved by identifying electrode misplacement or erroneous swapping of electrode position using AI. Remote monitoring has expanded greatly due to the emergence of contactless monitoring technology as wearable devices continue to develop and flourish. Parallel advances in AI computing power, ChatGPT, availability of large data sets, and more have greatly expanded applications in arrhythmia diagnosis, risk assessment, and treatment. More precise algorithms based on big data, personalized risk assessment, telemedicine and mobile health, smart hardware and wearables, and the exploration of rare or complex types of arrhythmia are the future direction.


Subject(s)
Arrhythmias, Cardiac , Artificial Intelligence , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Risk Assessment
15.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38693772

ABSTRACT

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Subject(s)
Arrhythmias, Cardiac , Cardiomyopathies , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Female , Male , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Middle Aged , Adult , Europe , Surveys and Questionnaires , Stroke Volume , Health Care Surveys , Anti-Arrhythmia Agents/therapeutic use , Practice Patterns, Physicians'/statistics & numerical data , Ventricular Function, Left , Catheter Ablation , Cardiologists
20.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793002

ABSTRACT

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Subject(s)
Heart Failure , Humans , Heart Failure/therapy , Heart Failure/diagnosis , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Monitoring, Physiologic/methods , Telemedicine/trends , Defibrillators, Implantable/standards