Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59.972
Filter
1.
Crit Care ; 28(1): 274, 2024 Aug 17.
Article in English | MEDLINE | ID: mdl-39154185

ABSTRACT

OBJECTIVE: Our study aimed to investigate the effects of different extracorporeal membrane oxygenation (ECMO) blood flow rates on lung perfusion assessment using the saline bolus-based electrical impedance tomography (EIT) technique in patients on veno-venous (VV) ECMO. METHODS: In this single-centered prospective physiological study, patients on VV ECMO who met the ECMO weaning criteria were assessed for lung perfusion using saline bolus-based EIT at various ECMO blood flow rates (gradually decreased from 4.5 L/min to 3.5 L/min, 2.5 L/min, 1.5 L/min, and finally to 0 L/min). Lung perfusion distribution, dead space, shunt, ventilation/perfusion matching, and recirculation fraction at different flow rates were compared. RESULTS: Fifteen patients were included. As the ECMO blood flow rate decreased from 4.5 L/min to 0 L/min, the recirculation fraction decreased significantly. The main EIT-based findings were as follows. (1) Median lung perfusion significantly increased in region-of-interest (ROI) 2 and the ventral region [38.21 (34.93-42.16)% to 41.29 (35.32-43.75)%, p = 0.003, and 48.86 (45.53-58.96)% to 54.12 (45.07-61.16)%, p = 0.037, respectively], whereas it significantly decreased in ROI 4 and the dorsal region [7.87 (5.42-9.78)% to 6.08 (5.27-9.34)%, p = 0.049, and 51.14 (41.04-54.47)% to 45.88 (38.84-54.93)%, p = 0.037, respectively]. (2) Dead space significantly decreased, and ventilation/perfusion matching significantly increased in both the ventral and global regions. (3) No significant variations were observed in regional and global shunt. CONCLUSIONS: During VV ECMO, the ECMO blood flow rate, closely linked to recirculation fraction, could affect the accuracy of lung perfusion assessment using hypertonic saline bolus-based EIT.


Subject(s)
Electric Impedance , Extracorporeal Membrane Oxygenation , Lung , Tomography , Humans , Extracorporeal Membrane Oxygenation/methods , Male , Female , Prospective Studies , Electric Impedance/therapeutic use , Middle Aged , Adult , Tomography/methods , Lung/blood supply , Lung/physiopathology , Lung/diagnostic imaging , Saline Solution, Hypertonic/therapeutic use , Aged , Blood Flow Velocity/physiology
2.
PLoS One ; 19(8): e0307384, 2024.
Article in English | MEDLINE | ID: mdl-39146288

ABSTRACT

BACKGROUND: Stress-transthoracic Doppler echocardiography (S-TDE) provides a noninvasive assessment of coronary flow parameters in the left anterior descending artery (LAD). However, the association between morphological characteristics and coronary flow changes after elective percutaneous coronary intervention (PCI) remains unclear. We aimed to evaluate the relationships between periprocedural coronary flow changes observed on S-TDE and lesion-specific plaque characteristics obtained by optical coherence tomography (OCT) in the interrogated vessels in patients with chronic coronary syndrome (CCS). METHODS AND RESULTS: Patients with CCS who underwent pre- and post-PCI S-TDE and elective fractional flow reserve (FFR)-guided PCI under OCT guidance for de novo single LAD lesions were included. S-TDE-derived hyperemic diastolic peak flow velocity (hDPV) was used as a surrogate for coronary flow. Lesions were categorized into two groups based on the %hDPV increase or decrease. The baseline clinical, physiological, and OCT findings were compared between the groups. In total, 103 LAD lesions were studied in 103 patients. After PCI, hDPV significantly increased from 55.6 cm/s to 69.5 cm/s (P<0.01), with a median %hDPV increase of 27.2 (6.32-59.1) %, while %hDPV decreased in 20 (19.4%) patients. The FFR improved in all patients. On OCT, layered plaques were more frequently present in the culprit vessels in the %hDPV-decrease group than in the %hDPV-increase group (85.0% vs. 50.6%, P = 0.01). Multivariable logistic regression analysis showed that the presence of layered plaques and high pre-PCI hDPV were independent predictors of %hDPV decrease. CONCLUSIONS: In patients who underwent successful uncomplicated elective PCI for de novo single LAD lesions, the presence of layered plaques was independently associated with hyperemic coronary flow decrease as assessed by S-TDE.


Subject(s)
Echocardiography, Doppler , Percutaneous Coronary Intervention , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Male , Female , Middle Aged , Aged , Percutaneous Coronary Intervention/methods , Echocardiography, Doppler/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Coronary Vessels/pathology , Stents , Fractional Flow Reserve, Myocardial , Hyperemia/diagnostic imaging , Hyperemia/physiopathology , Coronary Circulation/physiology , Blood Flow Velocity , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy
3.
Malawi Med J ; 36(1): 1-6, 2024 Mar.
Article in English | MEDLINE | ID: mdl-39086365

ABSTRACT

Background: The descending aorta velocity is important predictor of aortic disease in children and can be very helpful in some clinical and surgical decision making. Aim: The purpose of this study is to assess the normative values of descending aorta velocity among children from South-East Nigeria. It also aimed to assess the correlation between age, body surface area and mean velocity across the descending aorta. Methods: This is a cross-sectional study where the descending aorta velocity of one hundred and eleven children were enrolled consecutively using digitized two-dimensional and Doppler echocardiography. Results: A total of 111 children had echocardiography to study their cardiac structures and compute their mean scores of their descending aorta velocity. The mean velocity across the descending aorta was 1.3±0.2m/s with maximum and minimum velocities of 2.06 and 0.84cm respectively. The mean descending aorta velocity in males (1.37±0.24 m/s) was significantly higher than that in females (1.24±0.18); (Student T test 3.09, p = 0.03). There was no correlation between age and mean velocity across the descending aorta (Pearson correlation coefficient; -0.03, p = 0.7) nor between body surface area and descending aorta velocity (correlation coefficient 0.01, p= 0.8). Conclusions: The presented normalized values of the descending aorta velocity using a digitized two-dimensional and Doppler echocardiography among healthy children will serve as a reference values for further studies and can be applied for clinical and surgical use in children with various cardiac anomalies.


Subject(s)
Aorta, Thoracic , Echocardiography, Doppler , Humans , Male , Female , Cross-Sectional Studies , Child , Nigeria , Child, Preschool , Echocardiography, Doppler/methods , Blood Flow Velocity/physiology , Aorta, Thoracic/diagnostic imaging , Reference Values , Infant , Adolescent
4.
Ter Arkh ; 96(7): 701-705, 2024 Jul 30.
Article in Russian | MEDLINE | ID: mdl-39106514

ABSTRACT

The study of blood flow is becoming a new trend in cardiology and cardiovascular surgery. Based on the literature and our own data, a review is presented on the use of 4D flow in diseases of the heart and blood vessels. The main state of the question about the features of the application of the technique in various pathologies of the cardiovascular system is described in detail, the priorities, limitations and promising directions of the technique application are considered taking into account the goals of practical medicine. The review consists of two parts. The first is devoted to general issues, limitations of the technique, and issues of 4D flow mapping in patients with lesions of the great vessels. In the second part, the emphasis is on the use of 4D flow MRI in the study of intraventricular blood flow and the application of the technique in congenital heart and vascular diseases.


Subject(s)
Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/diagnostic imaging , Blood Flow Velocity/physiology
5.
Acta Neurochir (Wien) ; 166(1): 321, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39093519

ABSTRACT

PURPOSE: After a traumatic brain injury (TBI), monitoring of both macrovascular and microvascular blood circulation can potentially yield a better understanding of pathophysiology of potential secondary brain lesions. We investigated the changes in phase shift (PS) between cardiac-induced oscillations of cerebral blood flow (CBF) measured at macro (ultrasound Doppler) and microvascular (laser Doppler) level. Further we assessed the impact of intracranial pressure (ICP) on PS in TBI patients. A secondary aim was to compare PS to TCD-derived cerebral arterial time constant (τ), a parameter that reflects the circulatory transit time. METHODS: TCD blood flow velocities (FV) in the middle cerebral artery, laser Doppler blood microcirculation flux (LDF), arterial blood pressure (ABP), and ICP were monitored in 29 consecutive patients with TBI. Eight patients were excluded because of poor-quality signals. For the remaining 21 patients (median age = 23 (Q1: 20-Q3: 33); men:16,) data were retrospectively analysed. PS between the fundamental harmonics of FV and LDF signals was determined using spectral analysis. τ was estimated as a product of cerebrovascular resistance and compliance, based on the mathematical transformation of FV and ABP, ICP pulse waveforms. RESULTS: PS was negative (median: -26 (Q1: -38-Q3: -15) degrees) indicating that pulse LDF at a heart rate frequency lagged behind TCD pulse. With rising mean ICP, PS became more negative (R = -0.51, p < 0.019) indicating that delay of LDF pulse increases. There was a significant correlation between PS and cerebrovascular time constant (R = -0.47, p = 0.03). CONCLUSIONS: Pulse divergence between FV and LDF became greater with elevated ICP, likely reflecting prolonged circulatory travel time.


Subject(s)
Brain Injuries, Traumatic , Cerebrovascular Circulation , Intracranial Pressure , Microcirculation , Ultrasonography, Doppler, Transcranial , Humans , Brain Injuries, Traumatic/physiopathology , Brain Injuries, Traumatic/diagnostic imaging , Male , Cerebrovascular Circulation/physiology , Female , Adult , Young Adult , Ultrasonography, Doppler, Transcranial/methods , Intracranial Pressure/physiology , Microcirculation/physiology , Blood Flow Velocity/physiology , Retrospective Studies , Laser-Doppler Flowmetry/methods , Middle Cerebral Artery/physiopathology , Middle Cerebral Artery/diagnostic imaging
7.
J R Soc Interface ; 21(217): 20240194, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39173147

ABSTRACT

Blood flow reconstruction in the vasculature is important for many clinical applications. However, in clinical settings, the available data are often quite limited. For instance, transcranial Doppler ultrasound is a non-invasive clinical tool that is commonly used in clinical settings to measure blood velocity waveforms at several locations. This amount of data is grossly insufficient for training machine learning surrogate models, such as deep neural networks or Gaussian process regression. In this work, we propose a Gaussian process regression approach based on empirical kernels constructed by data generated from physics-based simulations-enabling near-real-time reconstruction of blood flow in data-poor regimes. We introduce a novel methodology to reconstruct the kernel within the vascular network. The proposed kernel encodes both spatiotemporal and vessel-to-vessel correlations, thus enabling blood flow reconstruction in vessels that lack direct measurements. We demonstrate that any prediction made with the proposed kernel satisfies the conservation of mass principle. The kernel is constructed by running stochastic one-dimensional blood flow simulations, where the stochasticity captures the epistemic uncertainties, such as lack of knowledge about boundary conditions and uncertainties in vasculature geometries. We demonstrate the performance of the model on three test cases, namely, a simple Y-shaped bifurcation, abdominal aorta and the circle of Willis in the brain.


Subject(s)
Models, Cardiovascular , Humans , Normal Distribution , Blood Flow Velocity/physiology , Cerebrovascular Circulation/physiology
8.
Open Heart ; 11(2)2024 Aug 19.
Article in English | MEDLINE | ID: mdl-39160086

ABSTRACT

BACKGROUND: Aortic conduit and reservoir functions can be directly measured by four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR). METHODS: Twenty healthy controls (10 young and 10 age-gender-matched old controls) and 20 patients with heart failure with preserved ejection fraction (HFpEF) were recruited. All had 4D flow CMR. Flow was quantified at the ascending and descending aorta levels. In addition, at the ascending aorta level, we quantified systolic flow displacement (FDs) and systolic flow reversal ratio (sFRR). The aortic conduit function was defined as the relative drop in systolic flow from the ascending to the descending aorta (∆Fs). Aortic reservoir function was defined as descending aortic diastolic stroke volume (DAo SVd). RESULTS: Both ∆Fs (R=0.51, p=0.001) and DAo SVd (R=-0.68, p=0.001) were significantly associated with ageing. Native T1 (R=0.51, p=0.001) and extracellular volume (R=0.51, p=0.001) showed maximum association with ∆Fs. ∆Fs significantly increased in HFpEF versus age-gender-matched controls (41±8% vs 52±12%, p=0.02). In multiple regression, only ∆Fs and DAo SVd were independent predictors of the estimated glomerular filtration rate (model R=0.77, p=0.0001). FDs was significantly associated with ∆Fs (R=0.4, p=0.01) and DAo SVd (R=-0.48, p=0.002), whereas sFRR was mainly associated with DAo SVd (R=-0.46, p=0.003). CONCLUSION: Both aortic conduit and reservoir function decline with age and this decline in aortic function is also independently associated with renal functional decline. Ascending aortic turbulent flow signatures are associated with loss of aortic conduit and reservoir functions. Finally, in HFpEF, aortic conduit and reservoir function demonstrate progressive decline. TRIALS REGISTRATION NUMBER: NCT05114785.


Subject(s)
Clinical Relevance , Heart Failure , Stroke Volume , Ventricular Function, Left , Female , Humans , Male , Aorta/diagnostic imaging , Aorta/physiopathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Blood Flow Velocity/physiology , Heart Failure/physiopathology , Heart Failure/diagnosis , Magnetic Resonance Imaging, Cine/methods , Stroke Volume/physiology , Ventricular Function, Left/physiology
9.
Cardiovasc Ultrasound ; 22(1): 11, 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39143500

ABSTRACT

BACKGROUND: In assessing the effects of smoking cessation on endothelial function, low-flow-mediated constriction (L-FMC) may provide complementary information to flow-mediated dilation (FMD). However, the value of flow-mediated total dilation (FMTD), an index that incorporates L-FMC into FMD, remains underreported. We aimed to evaluate the effect of smoking cessation on endothelial function, as assessed by FMD and FMTD, and clarify its associated clinical factors. METHODS: We enrolled 118 consecutive current smokers without previous coronary artery disease (72.9% were men; age: 59 ± 11 years) who underwent smoking cessation treatment. The clinical variables %FMD, %L-FMC, and %FMTD were examined before and 20 weeks after treatment initiation. A multivariate linear regression model was used to investigate the effects of smoking cessation on %FMD and %FMTD and the interaction between smoking cessation and baseline clinical variables. RESULTS: After 20 weeks, 85 smokers (69.4% were men; age: 59 ± 12 years) ceased smoking (abstainers), whereas 33 smokers (81.8% were men; age: 58 ± 11 years) did not (continued smokers). The estimated group differences (abstainers - continued smokers) in changes in the %FMD and %FMTD were 0.77% (95% confidence interval [CI], -0.22-1.77%; p = 0.129) and 1.17% (95% CI, 0.16-2.18%; p = 0.024), respectively. Smoking cessation-associated improvement in %FMTD was greater in women than in men (5.41% [95% CI, 3.15-7.67%] versus 0.24% [95% CI, -0.81-1.28%]; p-value for interaction, < 0.001). Additionally, a greater %FMTD improvement was observed in patients who smoked fewer cigarettes per day (p-value for interaction, 0.042) and those who had a smaller resting baseline lumen diameter (Dbase) (p-value for interaction, 0.023). CONCLUSIONS: Smoking cessation was associated with an improvement in %FMTD. Sex, cigarettes smoked per day, and Dbase significantly affected this improvement. The FMTD may help in risk stratification after smoking cessation.


Subject(s)
Endothelium, Vascular , Smoking Cessation , Vasodilation , Humans , Male , Female , Middle Aged , Smoking Cessation/methods , Endothelium, Vascular/physiopathology , Vasodilation/physiology , Brachial Artery/physiopathology , Smoking/physiopathology , Smoking/adverse effects , Blood Flow Velocity/physiology , Ultrasonography , Follow-Up Studies
10.
Comput Biol Med ; 180: 109010, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39159545

ABSTRACT

Platelet aggregation is a dynamic process that can obstruct blood flow, leading to cardiovascular diseases. While many studies have demonstrated clear connections between shear rate and platelet aggregation, the impact of flow-derived mechanical signals on this process is not fully understood. The objective of this work is to investigate the role of flow conditions on platelet aggregation dynamics, including effects on growth, shape, density composition, and their potential correlation with binding processes that are characterised by longer (e.g., via αIIbß3 integrin) and shorter (e.g., via VWF) initial binding times. In vitro blood perfusion experiments were conducted at wall shear rates of 800, 1600 and 4000 s-1. Detailed analysis of two modalities of experimental images was performed to offer insights into the morphology of platelet aggregates. A consistent structural pattern was observed across all samples: a high-density core enveloped by a low-density outer shell. An image-based 3D computational blood flow model was subsequently employed to study the local flow conditions, including binding availability time and flow-derived mechanical signals via shear rate and rate of elongation. The results show substantial dependence of the aggregation dynamics on these flow parameters. We found that the different binding mechanisms that prefer different flow regimes do not have a monotonic cross-over in efficiency as the flow increases. There is a significant dip in the cumulative aggregation potential in-between the preferred regimes. The results suggest that treatments targeting the biomechanical pathways could benefit from creating conditions that exploit these low-efficiency zones of aggregation.


Subject(s)
Blood Platelets , Platelet Aggregation , Humans , Platelet Aggregation/physiology , Blood Platelets/physiology , Blood Platelets/cytology , Blood Platelets/metabolism , Models, Cardiovascular , Blood Flow Velocity/physiology , Stress, Mechanical
11.
Sci Rep ; 14(1): 18837, 2024 08 13.
Article in English | MEDLINE | ID: mdl-39138303

ABSTRACT

Nonthrombotic iliac vein lesions (NIVLs) are significant causes of chronic venous insufficiency (CVI) in the left lower limb and symptom recurrence following left lower limb varicose vein treatment. The goal of this study was to explore the haemodynamic and morphological characteristics of iliac veins in patients with NIVLs. Pressure at the caudal end of the stenotic left common iliac vein (LCIV) segment, local blood flow velocity, and time-averaged wall shear stress in the stenotic segment exhibited positive correlations with the clinical CVI classification (R = 0.92, p < 0.001; R = 0.94, p < 0.001; R = 0.87, p < 0.001), while the relative retention time showed a negative correlation (R = -0.94, p < 0.001). The pressure difference (∆P) between the two ends of the stenotic segment and the velocity difference (∆V) between the stenotic segment and the caudal end were positively correlated with the clinical classification (R = 0.92, p < 0.001; R = 0.9, p < 0.001). The cross-sectional area stenosis rate and length of the stenotic LCIV segment were positively correlated with the clinical classification (R = 0.93, p < 0.001; R = 0.63, p < 0.001). The results suggest that haemodynamic assessment of the iliac vein could effectively portray blood flow disturbances in stenotic segments of the LCIV, potentially reflecting the degree of iliac vein stenosis. Haemodynamic indicators are correlated with the severity of clinical CVI symptoms.


Subject(s)
Hemodynamics , Iliac Vein , Venous Insufficiency , Humans , Iliac Vein/physiopathology , Iliac Vein/pathology , Male , Female , Middle Aged , Venous Insufficiency/physiopathology , Venous Insufficiency/pathology , Aged , Adult , Blood Flow Velocity , Constriction, Pathologic
12.
J Am Heart Assoc ; 13(16): e030775, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-39119951

ABSTRACT

BACKGROUND: Obesity is associated with resistance to the metabolic (glucose uptake) and vascular (nitric-oxide mediated dilation and microvascular recruitment) actions of insulin. These vascular effects contribute to insulin sensitivity by increasing tissue delivery of glucose. Studies by us and others suggest that sympathetic activation contributes to insulin resistance to glucose uptake. Here we tested the hypothesis that sympathetic activation contributes to impaired insulin-mediated vasodilation in adult subjects with obesity. METHODS AND RESULTS: In a randomized crossover study, we used a euglycemic hyperinsulinemic clamp in 12 subjects with obesity to induce forearm arterial vasodilation (forearm blood flow) and microvascular recruitment (contrast-enhanced ultrasonography) during an intrabrachial infusion of saline (control) or phentolamine (sympathetic blockade). Insulin increased forearm blood flow on both study days (from 2.21±1.22 to 4.89±4.21 mL/100 mL per min, P=0.003 and from 2.42±0.89 to 7.19±3.35 mL/100 mL per min, P=0.002 for the intact and blocked day, respectively). Sympathetic blockade with phentolamine resulted in a significantly greater increase in microvascular flow velocity (∆microvascular flow velocity: 0.23±0.65 versus 2.51±3.01 arbitrary intensity units (AIU/s) for saline and phentolamine respectively, P=0.005), microvascular blood volume (∆microvascular blood volume: 1.69±2.45 versus 3.76±2.93 AIU, respectively, P=0.05), and microvascular blood flow (∆microvascular blood flow: 0.28±0.653 versus 2.51±3.01 AIU2/s, respectively, P=0.0161). To evaluate if this effect was not due to nonspecific vasodilation, we replicated the study in 6 subjects with obesity comparing intrabrachial infusion of phentolamine to sodium nitroprusside. At doses that produced similar increases in forearm blood flow, insulin-induced changes in microvascular flow velocity were greater during phentolamine than sodium nitroprusside (%microvascular flow velocity=58% versus 29%, respectively, P=0.031). CONCLUSIONS: We conclude that sympathetic activation impairs insulin-mediated microvascular recruitment in adult subjects with obesity.


Subject(s)
Cross-Over Studies , Forearm , Insulin , Microcirculation , Obesity , Phentolamine , Regional Blood Flow , Sympathetic Nervous System , Vasodilation , Humans , Forearm/blood supply , Male , Phentolamine/pharmacology , Female , Obesity/physiopathology , Vasodilation/drug effects , Vasodilation/physiology , Adult , Sympathetic Nervous System/physiopathology , Sympathetic Nervous System/drug effects , Regional Blood Flow/drug effects , Microcirculation/drug effects , Blood Flow Velocity , Middle Aged , Glucose Clamp Technique , Insulin Resistance , Autonomic Nerve Block/methods
13.
Sci Rep ; 14(1): 19658, 2024 08 23.
Article in English | MEDLINE | ID: mdl-39179594

ABSTRACT

Flow fluctuations have emerged as a promising hemodynamic metric for understanding of hemodynamics in intracranial aneurysms. Several investigations have reported flow instabilities using numerical tools. In this study, the occurrence of flow fluctuations is investigated using either Newtonian or non-Newtonian fluid models in five patient-specific intracranial aneurysms using high-resolution lattice Boltzmann simulation methods. Flow instabilities are quantified by computing power spectral density, proper orthogonal decomposition, and fluctuating kinetic energy of velocity fluctuations. Our simulations reveal substantial flow instabilities in two of the ruptured aneurysms, where the pulsatile inflow through the neck leads to hydrodynamic instability, particularly around the rupture position, throughout the entire cardiac cycle. In other monitoring points, the flow instability is primarily observed during the deceleration phase; typically, the fluctuations begin just after peak systole, gradually decay, and the flow returns to its original, laminar pulsatile state during diastole. Additionally, we assess the rheological impact on flow dynamics. The disparity between Newtonian and non-Newtonian outcomes remains minimal in unruptured aneurysms, with less than a 5% difference in key metrics. However, in ruptured cases, adopting a non-Newtonian model yields a substantial increase in the fluctuations within the aneurysm sac, with up to a 30% higher fluctuating kinetic energy compared to the Newtonian model. The study highlights the importance of using appropriate high-resolution simulations and non-Newtonian models to capture flow fluctuation characteristics that may be critical for assessing aneurysm rupture risk.


Subject(s)
Aneurysm, Ruptured , Hemodynamics , Intracranial Aneurysm , Intracranial Aneurysm/physiopathology , Humans , Aneurysm, Ruptured/physiopathology , Blood Flow Velocity , Hydrodynamics , Models, Cardiovascular , Computer Simulation , Cerebrovascular Circulation/physiology , Pulsatile Flow
15.
Echocardiography ; 41(8): e15901, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39115456

ABSTRACT

PURPOSE: Cardiogenic shock still has a high mortality. In order to correctly manage these patients, it is useful to have available haemodynamic parameters, invasive and non-invasive. The aim of this review is to show the current evidence on the use of echocardiographic aortic flow assessment by left ventricular outflow tract - velocity time integral. METHODS: Publications relevant to the discussion of echocardiographic aortic flow assessment by left ventricular outflow tract - velocity time integral and cardiogenic shock, were retrieved from PubMed®. RESULTS: Left ventricular outflow tract - velocity time integral is an easily sampled and reproducible parameter that has already been shown to have prognostic value in various cardiovascular pathologies, including myocardial infarction and heart failure. Although there are still few data available in the literature, the LVOT-VTI also seems to have an important role in CS from prognosis to guidance in the escalation/de-escalation of vasoactive therapy and to support devices by allowing an estimate of patient's probability of response to fluid administration. CONCLUSION: Aortic flow assessment can become a very useful invasive parameter in the management of cardiogenic shock.


Subject(s)
Echocardiography, Doppler , Shock, Cardiogenic , Humans , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnostic imaging , Echocardiography, Doppler/methods , Blood Flow Velocity/physiology , Aorta/diagnostic imaging , Aorta/physiopathology , Prognosis
16.
Int J Med Sci ; 21(9): 1604-1611, 2024.
Article in English | MEDLINE | ID: mdl-39006846

ABSTRACT

Purpose: To investigate morphological and hemodynamic characteristics of the ophthalmic artery (OA) in patients with white matter hyperintensity (WMH), and the association of the presence and severity of WMH with OA characteristics. Methods: This cross-sectional study included 44 eyes of 25 patients with WMH and 38 eyes of 19 controls. The Fazekas scale was adopted as criteria for evaluating the severity of white matter hyperintensities. The morphological characteristics of the OA were measured on the basis of three-dimensional reconstruction. The hemodynamic parameters of the OA were calculated using computational fluid dynamics simulations. Results: Compared with the control group, the diameter (16.0±0.27 mm vs. 1.71±0.18 mm, P=0.029), median blood flow velocity (0.12 m/s vs. 0.22 m/s, P<0.001), mass flow ratio (2.16% vs. 3.94%, P=0.012) and wall shear stress (2.65 Pa vs. 9.31 Pa, P<0.001) of the OA in patients with WMH were significantly decreased. After adjusting for confounding factors, the diameter, blood flow velocity, wall shear stress, and mass flow ratio of the OA were significantly associated with the presence of WMH. Male sex and high low-density protein level were associated with moderate-to-severe total WMH, and smoking was associated with the moderate-to-severe periventricular WMH. Conclusions: The diameter, blood flow velocity, mass flow ratio, and wall shear stress of the OA were independently associated with the presence of WMH. Atherosclerosis might be involved in the common mechanism of the occurrence of WMH and the OA changes.


Subject(s)
Hemodynamics , Ophthalmic Artery , White Matter , Humans , Male , Female , Ophthalmic Artery/diagnostic imaging , Ophthalmic Artery/physiopathology , White Matter/diagnostic imaging , White Matter/physiopathology , White Matter/blood supply , White Matter/pathology , Cross-Sectional Studies , Hemodynamics/physiology , Middle Aged , Aged , Blood Flow Velocity , Magnetic Resonance Imaging , Adult
17.
Int J Sports Physiol Perform ; 19(9): 932-938, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39043362

ABSTRACT

PURPOSE: There are multiple postexercise recovery technologies available in the market based on the assumption of blood-flow enhancement. Lower-limb intermittent pneumatic compression (IPC) has been widely used, but the available scientific evidence supporting its effectiveness remains scarce, requiring a deeper investigation into its underlying mechanisms. The aim of this study was to assess the hemodynamic effects caused by the use of IPC at rest. METHODS: Twenty-two soccer and track and field athletes underwent two 15-minute IPC protocols (moderate- [80 mm Hg] and high-pressure [200 mm Hg]) in a randomized order. Systolic peak velocity, end-diastolic peak velocity, arterial diameter, and heart rate were measured before, during (at the eighth minute), and 2 minutes after each IPC protocol. RESULTS: Significant effects were observed between before and during (eighth minute) the IPC protocol for measures of systolic (P < .001) and end-diastolic peak velocities (P < .001), with the greater effects observed during the high-pressure protocol. Moreover, 2 minutes after each IPC protocol, hemodynamic variables returned to values close to baseline. Arterial diameter presented significant differences between pressures during the IPC protocols (P < .05), while heart rate remained unaltered. CONCLUSION: IPC effectively enhances transitory blood flow of athletes, particularly when applying high-pressure protocols.


Subject(s)
Cross-Over Studies , Heart Rate , Hemodynamics , Intermittent Pneumatic Compression Devices , Soccer , Humans , Soccer/physiology , Heart Rate/physiology , Male , Hemodynamics/physiology , Young Adult , Double-Blind Method , Track and Field/physiology , Adult , Blood Flow Velocity/physiology , Athletes , Regional Blood Flow , Lower Extremity/blood supply , Lower Extremity/physiology
18.
J Biomech ; 173: 112237, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39067183

ABSTRACT

Recent computational and experimental studies of intracranial aneurysms have revealed potential mechanisms of aneurysm bruits and murmurs, driven by flow instabilities rather than by stable pulsatile flow. Some of these studies have been conducted under the assumption of constant flow rate (steady flow); however the validity of this assumption has not been evaluated for high-frequency flow instability, or vibrations from fluid-structure interaction (FSI) simulations. We evaluated the time-averaged wall shear stress, flow instability and vibration amplitude of steady flow simulations, performed at both cycle-averaged and peak-systolic flow rates, and compared these to recent pulsatile FSI simulations. Wall shear stress fields of pulsatile flow (time-averaged and peak values) were well-approximated by the respective steady-flow FSI simulations, and the spatial distribution and frequency content of flow instability and vibrations were reasonably approximated by the steady flow simulations at peak-systolic flow rates. However, the level of flow instability and vibration was generally over-predicted by the steady flow simulations at peak-systolic flow rates as flow remained unstable for longer than in the pulsatile simulation, while no flow instability was detected for steady flow at cycle-averaged flow rates. Additionally, the amplitude of flow instability and vibration fluctuated considerably in the steady flow simulations, while the pulsatile simulations exhibited consistent vibration amplitudes (less than 10 % variation at peak systole between cycles). Finally, steady flow simulations at peak-systolic conditions required 2-3x more compute time than the pulsatile simulations for the same time duration. Therefore, we recommend using pulsatile flow simulations when investigating vibrations and flow instabilities.


Subject(s)
Computer Simulation , Intracranial Aneurysm , Models, Cardiovascular , Pulsatile Flow , Vibration , Intracranial Aneurysm/physiopathology , Humans , Pulsatile Flow/physiology , Blood Flow Velocity/physiology , Stress, Mechanical , Cerebrovascular Circulation/physiology
19.
Sci Rep ; 14(1): 17732, 2024 07 31.
Article in English | MEDLINE | ID: mdl-39085313

ABSTRACT

Permanent residence at high-altitude and chronic mountain sickness (CMS) may alter the cerebrovascular homeostasis and orthostatic responses. Healthy male participants living at sea-level (LL; n = 15), 3800 m (HL3800m; n = 13) and 5100 m (HL5100m; n = 17), respectively, and CMS highlanders living at 5100 m (n = 31) were recruited. Middle cerebral artery mean blood flow velocity (MCAv), cerebral oxygen delivery (CDO2), mean blood pressure (MAP), heart rate variability and spontaneuous cardiac baroreflex sensitivity (cBRS) were assessed while sitting, initial 30 s and after 3 min of standing. Cerebral autoregulation index (ARI) was estimated (ΔMCAv%baseline)/ΔMAP%baseline) in response to the orthostatic challenge. Altitude and CMS were associated with hypoxemia and elevated hemoglobin concentration. While sitting, MCAv and LFpower negatively correlated with altitude but were not affected by CMS. CDO2 remained preserved. BRS was comparable across all altitudes, but lower with CMS. Within initial 30 s of standing, altitude and CMS correlated with a lesser ΔMAP while ARI remained unaffected. After 3 min standing, MCAv, CDO2 and cBRS remained preserved across altitudes. The LF/HF ratio increased in HL5100m compared to LL and HL3800m from sitting to standing. In contrary, CMS showed blunted autonomic nervous activation in responses to standing. Despite altitude- and CMS-associated hypoxemia, erythrocytosis and impaired blood pressure regulation (CMS only), cerebral homeostasis remained overall preserved.


Subject(s)
Altitude Sickness , Altitude , Baroreflex , Blood Pressure , Cerebrovascular Circulation , Heart Rate , Homeostasis , Humans , Male , Altitude Sickness/physiopathology , Adult , Blood Pressure/physiology , Heart Rate/physiology , Baroreflex/physiology , Cerebrovascular Circulation/physiology , Middle Aged , Blood Flow Velocity , Middle Cerebral Artery/physiopathology , Hypoxia/physiopathology
20.
Cardiovasc Intervent Radiol ; 47(8): 1119-1126, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38992198

ABSTRACT

PURPOSE: Quantitative digital subtraction angiography (qDSA) has been proposed to quantify blood velocity for monitoring treatment progress during blood flow altering interventions. The method requires high frame rate imaging [~ 30 frame per second (fps)] to capture temporal dynamics. This work investigates performance of qDSA in low radiation dose acquisitions to facilitate clinical translation. MATERIALS AND METHODS: Velocity quantification accuracy was evaluated at five radiation dose rates in vitro and in vivo. Angiographic technique ranged from 30 fps digital subtraction angiography ( 29.3 ± 1.7 mGy / s at the interventional reference point) down to a 30 fps protocol at 23% higher radiation dose per frame than fluoroscopy ( 1.1 ± 0.2 mGy / s ). The in vitro setup consisted of a 3D-printed model of a swine hepatic arterial tree connected to a pulsatile displacement pump. Five different flow rates (3.5-8.8 mL/s) were investigated in vitro. Angiography-based fluid velocity measurements were compared across dose rates using ANOVA and Bland-Altman analysis. The experiment was then repeated in a swine study (n = 4). RESULTS: Radiation dose rate reductions for the lowest dose protocol were 99% and 96% for the phantom and swine study, respectively. No significant difference was found between angiography-based velocity measurements at different dose rates in vitro or in vivo. Bland-Altman analysis found little bias for all lower-dose protocols (range: [- 0.1, 0.1] cm/s), with the widest limits of agreement ([- 3.3, 3.5] cm/s) occurring at the lowest dose protocol. CONCLUSIONS: This study demonstrates the feasibility of quantitative blood velocity measurements from angiographic images acquired at reduced radiation dose rates.


Subject(s)
Angiography, Digital Subtraction , Radiation Dosage , Animals , Angiography, Digital Subtraction/methods , Swine , Blood Flow Velocity , Hepatic Artery/diagnostic imaging , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL