Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52.501
Filter
2.
JACC Heart Fail ; 12(7): 1141-1156, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38960519

ABSTRACT

Heart failure is a clinical syndrome characterized by the inability of the heart to meet the circulatory demands of the body without requiring an increase in intracardiac pressures at rest or with exertion. Hemodynamic parameters can be measured via right heart catheterization, which has an integral role in the full spectrum of heart failure: from ambulatory patients to those in cardiogenic shock, as well as patients being considered for left ventricular device therapy and heart transplantation. Hemodynamic data are critical for prompt recognition of clinical deterioration, assessment of prognosis, and guidance of treatment decisions. This review is a field guide for hemodynamic assessment, troubleshooting, and interpretation for clinicians treating patients with heart failure.


Subject(s)
Cardiac Catheterization , Heart Failure , Hemodynamics , Humans , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Cardiac Catheterization/methods , Hemodynamics/physiology
3.
JACC Cardiovasc Interv ; 17(13): 1559-1573, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986655

ABSTRACT

BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Hemodynamics , Mitral Valve Insufficiency , Mitral Valve , Recovery of Function , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Male , Female , Aged , Treatment Outcome , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Risk Factors , Time Factors , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/diagnostic imaging , Heart Failure/etiology , Risk Assessment
10.
Ann Card Anaesth ; 27(3): 220-227, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38963356

ABSTRACT

CONTEXT: Left atrial appendage closure (LAAC) was developed as a novel stroke prevention alternative for patients with atrial fibrillation, particularly for those not suitable for long-term oral anticoagulant therapy. Traditionally, general anesthesia (GA) has been more commonly used primarily due to the necessity of transesophageal echocardiography. AIMS: Compare trends of monitored anesthesia care (MAC) versus GA for percutaneous transcatheter LAAC with endocardial implant and assess for independent variables associated with primary anesthetic choice. SETTINGS AND DESIGN: Multi-institutional data collected from across the United States using the National Anesthesia Clinical Outcomes Registry. MATERIAL AND METHODS: Retrospective data analysis from 2017-2021. STATISTICAL ANALYSIS USED: Independent-sample t tests or Mann-Whitney U tests were used for continuous variables and Chi-square tests or Fisher's exact test for categorical variables. Multivariate logistic regression was used to assess patient and hospital characteristics. RESULTS: A total of 19,395 patients underwent the procedure, and 352 patients (1.8%) received MAC. MAC usage trended upward from 2017-2021 (P < 0.0001). MAC patients were more likely to have an American Society of Anesthesiologists (ASA) physical status of≥ 4 (33.6% vs 22.89%) and to have been treated at centers in the South (67.7% vs 44.2%), in rural locations (71% vs 39.5%), and with lower median annual percutaneous transcatheter LAAC volume (102 vs 153 procedures) (all P < 0.0001). In multivariate analysis, patients treated in the West had 85% lower odds of receiving MAC compared to those in the Northeast (AOR: 0.15; 95% CI 0.03-0.80, P = 0.0261). CONCLUSIONS: While GA is the most common anesthetic technique for percutaneous transcatheter closure of the left atrial appendage, a small, statistically significant increase in MAC occurred from 2017-2021. Anesthetic management for LAAC varies with geographic location.


Subject(s)
Anesthesia, General , Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Registries , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Retrospective Studies , Aged , Cardiac Catheterization/methods , Cardiac Catheterization/statistics & numerical data , Atrial Fibrillation/surgery , Anesthesia, General/methods , Anesthesia, General/statistics & numerical data , United States , Aged, 80 and over , Middle Aged , Echocardiography, Transesophageal/methods , Treatment Outcome , Stroke/prevention & control , Stroke/epidemiology
12.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39007829

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , Male , Female , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Aged , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Treatment Outcome , Aged, 80 and over , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis , Risk Factors , Middle Aged
14.
J Pak Med Assoc ; 74(6 (Supple-6)): S57-S60, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39018140

ABSTRACT

Coronary artery fistula is a rare anomaly involving the coronary artery and a heart chamber or vessel. Percutaneous intervention has been shown to be effective and safe in fistulas that are small and nontortuous; however, it is not an absolute contraindication in fistulas that are large and tortuous. We report a delayed diagnosis of a single, large-diameter, tortuous coronary artery fistula that manifested as myocardial ischaemia due to the steal phenomenon in a 49 year old male. The undesirable connection was successfully obliterated by percutaneous embolisation, followed by an improvement in symptoms and daily activities. Steal phenomenon is the fundamental mechanism of myocardial ischaemia in coronary artery fistula, as confirmed by improvement in symptoms and coronary artery perfusion following occlusion of the fistula. Percutaneous catheterization is safe and effective for coronary artery fistula closure, and the occlusion site should be precise to achieve complete occlusion and prevent complications.


Subject(s)
Embolization, Therapeutic , Humans , Male , Middle Aged , Embolization, Therapeutic/methods , Coronary Vessel Anomalies/therapy , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Vascular Fistula/therapy , Vascular Fistula/diagnostic imaging , Myocardial Ischemia/therapy , Myocardial Ischemia/etiology , Cardiac Catheterization/methods , Coronary Vessels/diagnostic imaging
15.
J Pak Med Assoc ; 74(6 (Supple-6)): S77-S80, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39018145

ABSTRACT

Atrial Septal Defect closure in childhood and early adulthood has a good prognosis, but in older individuals the risk-benefit ratio is not as straightforward. We report a 57-year-old man who was easily fatigued when exercising. The cardiac examination revealed a wide and fixed splitting of S2, a pulmonary ejection systolic murmur grade III/VI, and increased jugular venous pressure. The transesophageal echocardiography showed Atrial Septal Defect secundum with a diameter of 20 mm, L-to-R shunt, and 5 mm, a thin and floppy inferior rim. The patient underwent surgical Atrial Septal Defect closure. The deficient posteroinferior rim occurs only in 3.3% of patients with secundum Atrial Septal Defect. This condition will enhance the likelihood of occluder dislodgement in the transcatheter closure approach. We learn from this case that surgical Atrial Septal Defect closure may be an option for elderly patients if there is an inadequate, thin, and floppy inferior rim or no comorbidities.


Subject(s)
Echocardiography, Transesophageal , Heart Septal Defects, Atrial , Humans , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Male , Middle Aged , Cardiac Catheterization/methods , Septal Occluder Device
16.
Circ Cardiovasc Interv ; 17(7): e013739, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38973456

ABSTRACT

BACKGROUND: While transradial access is favored for cardiac catheterization, the radial artery (RA) is increasingly preferred for coronary artery bypass grafting. Whether the RA is suitable for use as a graft following instrumentation for transradial access remains uncertain. METHODS: Consecutive patients from 2015 to 2019 who underwent coronary artery bypass grafting using both the left and right RAs as grafts were included. Instrumented RAs underwent careful preoperative assessment for suitability. The clinical analysis was stratified by whether patients received an instrumented RA graft (instrumented versus noninstrumented groups). Eligible patients with both instrumented and noninstrumented RAs underwent computed tomography coronary angiography to evaluate graft patency. The primary outcome was a within-patient paired analysis of graft patency comparing instrumented to noninstrumented RA grafts. RESULTS: Of the 1123 patients who underwent coronary artery bypass grafting, 294 had both the left and right RAs used as grafts and were included. There were 126 and 168 patients in the instrumented and noninstrumented groups, respectively. Baseline characteristics and perioperative outcomes were comparable. The rate of major adverse cardiac events at 2 years following coronary artery bypass grafting was 2.4% in the instrumented group and 5.4% in the noninstrumented group (hazard ratio, 0.44 [95% CI, 0.12-1.61]; P=0.19). There were 50 patients included in the graft patency analysis. At a median follow-up of 4.3 (interquartile range, 3.7-4.5) years, 40/50 (80%) instrumented and 41/50 (82%) noninstrumented grafts were patent (odds ratio, 0.86 [95% CI, 0.29-2.52]; P>0.99). No significant differences were observed in the luminal diameter or cross-sectional area of the instrumented and noninstrumented RA grafts. CONCLUSIONS: There was no evidence found in this study that RA graft patency was affected by prior transradial access, and the use of an instrumented RA was not associated with worse outcomes in the exploratory clinical analysis. Although conduits must be carefully selected, prior transradial access should not be considered an absolute contraindication to the use of the RA as a bypass graft. REGISTRATION: URL: https://www.anzctr.org.au/; Unique identifier: ACTRN12621000257864.


Subject(s)
Cardiac Catheterization , Coronary Angiography , Coronary Artery Bypass , Coronary Artery Disease , Graft Occlusion, Vascular , Radial Artery , Vascular Patency , Humans , Radial Artery/diagnostic imaging , Radial Artery/transplantation , Radial Artery/physiopathology , Male , Female , Coronary Artery Bypass/adverse effects , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Middle Aged , Treatment Outcome , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/diagnostic imaging , Time Factors , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Coronary Artery Disease/therapy , Coronary Artery Disease/surgery , Risk Factors , Retrospective Studies , Catheterization, Peripheral/adverse effects , Punctures , Risk Assessment
17.
Circ Cardiovasc Imaging ; 17(7): e016424, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39012942

ABSTRACT

BACKGROUND: It remains unknown to what extent intrinsic atrial cardiomyopathy or left ventricular diastolic dysfunction drive atrial remodeling and functional failure in heart failure with preserved ejection fraction (HFpEF). Computational 3-dimensional (3D) models fitted to cardiovascular magnetic resonance allow state-of-the-art anatomic and functional assessment, and we hypothesized to identify a phenotype linked to HFpEF. METHODS: Patients with exertional dyspnea and diastolic dysfunction on echocardiography (E/e', >8) were prospectively recruited and classified as HFpEF or noncardiac dyspnea based on right heart catheterization. All patients underwent rest and exercise-stress right heart catheterization and cardiovascular magnetic resonance. Computational 3D anatomic left atrial (LA) models were generated based on short-axis cine sequences. A fully automated pipeline was developed to segment cardiovascular magnetic resonance images and build 3D statistical models of LA shape and find the 3D patterns discriminant between HFpEF and noncardiac dyspnea. In addition, atrial morphology and function were quantified by conventional volumetric analyses and deformation imaging. A clinical follow-up was conducted after 24 months for the evaluation of cardiovascular hospitalization. RESULTS: Beyond atrial size, the 3D LA models revealed roof dilation as the main feature found in masked HFpEF (diagnosed during exercise-stress only) preceding a pattern shift to overall atrial size in overt HFpEF (diagnosed at rest). Characteristics of the 3D model were integrated into the LA HFpEF shape score, a biomarker to characterize the gradual remodeling between noncardiac dyspnea and HFpEF. The LA HFpEF shape score was able to discriminate HFpEF (n=34) to noncardiac dyspnea (n=34; area under the curve, 0.81) and was associated with a risk for atrial fibrillation occurrence (hazard ratio, 1.02 [95% CI, 1.01-1.04]; P=0.003), as well as cardiovascular hospitalization (hazard ratio, 1.02 [95% CI, 1.00-1.04]; P=0.043). CONCLUSIONS: LA roof dilation is an early remodeling pattern in masked HFpEF advancing to overall LA enlargement in overt HFpEF. These distinct features predict the occurrence of atrial fibrillation and cardiovascular hospitalization. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03260621.


Subject(s)
Atrial Function, Left , Atrial Remodeling , Heart Atria , Heart Failure , Magnetic Resonance Imaging, Cine , Stroke Volume , Ventricular Function, Left , Humans , Heart Failure/physiopathology , Heart Failure/diagnosis , Female , Male , Stroke Volume/physiology , Aged , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Prospective Studies , Middle Aged , Ventricular Function, Left/physiology , Imaging, Three-Dimensional , Cardiac Catheterization , Predictive Value of Tests , Dyspnea/physiopathology , Dyspnea/etiology , Dyspnea/diagnosis
19.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872098

ABSTRACT

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Pulmonary Valve , Recovery of Function , Humans , Male , Child , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Pulmonary Valve/diagnostic imaging , Treatment Outcome , Young Adult , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Time Factors , Adult , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/diagnostic imaging , Bioprosthesis , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Stenosis/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Retrospective Studies , Risk Factors , Asia, Southeastern
SELECTION OF CITATIONS
SEARCH DETAIL