Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.156
Filter
1.
Am J Dent ; 37(3): 141-146, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899994

ABSTRACT

PURPOSE: To evaluate the effect of air abrasion and polishing procedures on roughness and color stability of ceramic and composite materials after artificial accelerated aging. METHODS: In this study, six restorative materials were tested: feldspathic ceramic (CEREC Blocks), glass ceramic (IPS e.max CAD), resin-based hybrid ceramic (Cerasmart), microhybrid composite (Charisma Classic), nanohybrid composite (Charisma Diamond) and nanoceramic composite (CeramXOne). Forty square-shaped composite specimens were fabricated from each composite and CAD-CAM ceramic material. Initial surface roughness measurements were performed using a profilometer and color measurements of each specimen with a spectrophotometer. Ten control specimens for each group did not receive air abrasion. The other specimens were treated by an air abrasion device and then were randomly divided into three subgroups of 10 specimens (n= 10). After air abrasion, 10 specimens of each group did not receive polishing (Air abrasion group) and others were repolished with Sof-Lex kit (Sof-Lex group) or a rubber kit (Rubber group). Surface roughness and color measurements were repeated before and after 300 hours of artificial accelerated aging (AAA). The univariate test and then three-way ANOVA and two-way ANOVA were performed for comparison of groups (α= 0.05). RESULTS: The univariate statistical analysis revealed that the restorative materials were differently affected after air abrasion, polishing methods and AAA (P< 0.001). Three-way ANOVA showed that the surface roughness of the restorative materials increased after air abrasion and AAA (P< 0.001). Two-way ANOVA showed statistically significant differences between color changes of ceramic (CEREC and IPS e.max CAD) and composite based restorative materials (P< 0.001). CLINICAL SIGNIFICANCE: Clinicians should be aware that air abrasion at a specified power and time significantly changes the surface roughness of the materials except for CEREC. Additionally, polishing procedures (Sof-Lex, Rubber) did not significantly reduce the surface roughness of the ceramic groups. After air abrasion, depending on the material type used clinically, restorations should be repolished to reduce roughness and ensure color stability.


Subject(s)
Ceramics , Color , Composite Resins , Dental Polishing , Dental Porcelain , Materials Testing , Surface Properties , Dental Polishing/methods , Composite Resins/chemistry , Ceramics/chemistry , Dental Porcelain/chemistry , Dental Materials/chemistry , Air Abrasion, Dental , Time Factors , Computer-Aided Design , Aluminum Silicates/chemistry , Spectrophotometry , Humans , Potassium Compounds/chemistry
2.
Am J Dent ; 37(3): 147-153, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899995

ABSTRACT

PURPOSE: To investigate the discoloration, line roughness and gloss of conventional and universal shade resin-based composites. METHODS: Clearfil AP-X (AP-X) and Estelite Sigma Quick (EQ) samples were prepared. Discoloration, roughness, and gloss were measured on mirror-polished, alkaline-degraded, and repolished surfaces. The superficial layer degraded by alkaline immersion (degraded layer) was ground off from the sample surface. After removing the degraded layer, the surface was polished with aluminum oxide powder (1.0 µm and 0.3 µm), to create a repolished specimen. Scanning electron microscopy observations were made of the specimens. RESULTS: The results were compared with those for Omnichroma (OC) from a previous study. All the materials showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials. CLINICAL SIGNIFICANCE: The materials tested showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials.


Subject(s)
Color , Composite Resins , Surface Properties , Composite Resins/chemistry , Materials Testing , Microscopy, Electron, Scanning , Dental Polishing/methods , Aluminum Oxide/chemistry
3.
Am J Dent ; 37(3): 159-163, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899997

ABSTRACT

PURPOSE: To evaluate different polishing methods' effects on the color stability of recent resin composites. METHODS: 160 samples for color stability evaluation and 40 samples for the degree of conversion evaluation were prepared with four different resin composites [Harmonize (H), Filtek Universal (F), Omnichroma (O), Essentia Universal (E)] and light cured. For color stability evaluation, samples prepared from each resin composite were divided into four groups: three polishing procedures and a control group. The ΔE00 was calculated between initial, and after immersion in coffee solution for 12 days. The degree of conversion was evaluated with Fourier Transform Infrared Spectroscopy. The statistical analysis of ΔE00 values was made with the two-way ANOVA, Tukey HSD, and Tamhane's T2 tests. One-way ANOVA and Tukey HSD tests were used to compare the degree of conversion values (P< 0.05). RESULTS: In all composite groups, mylar (control) groups had the highest ΔE00, and no differences between other polishing procedures. According to the polishing procedures, Omnichroma showed the highest ΔE00 values (on mylar groups O vs F, P< 0.001; O vs H, P< 0.001; O vs E, P< 0.001). There was a significant difference between the composite groups in terms of the degree of monomer conversion (P< 0.05). Omnichroma showed, significantly, the highest discoloration. CLINICAL SIGNIFICANCE: Different polishing procedures showed effective performance on current composite surfaces. Omnichroma resin composite showed higher color change than composites with similar properties.


Subject(s)
Color , Composite Resins , Dental Polishing , Composite Resins/chemistry , Dental Polishing/methods , Surface Properties , Materials Testing , Spectroscopy, Fourier Transform Infrared
4.
BMC Oral Health ; 24(1): 651, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831398

ABSTRACT

BACKGROUND: Carious/Non-carious cervical lesions with gingival recessions may require both dental and periodontal reconstructive therapy, where flaps/grafts may be placed in contact with a dental filling material. Human Gingival Fibroblasts (HGF-1) response during the early phase of healing could vary according to the procedures employed to cure the dental composite. Moreover, oxygen diffusion into dental composite inhibits the polymerization reaction, creating an oxygen-inhibited layer (OIL) that presents residual unreacted monomers. The aim of this study was to assess the effect of different polishing techniques and OIL on HGF-1. METHODS: Composite discs polished with different techniques (diamond rubber, abrasive discs and tungsten carbide burr) were used. An additional not polished smooth group obtained with and without OIL was used as control. Samples were physically characterized through the analysis of their hydrophilicity and surface topography through contact angle measurement and SEM, respectively; afterwards the biologic response of HGF-1 when cultured on the different substrates was analyzed in terms of cytotoxicity and gene expression. RESULTS: The finishing systems caused alterations to the wettability, even if without a proportional relation towards the results of the proliferation essay, from which emerges a greater proliferation on surfaces polished with one-step diamond rubber and with abrasive discs as well as a direct effect of the glycerin layer, confirming that surface roughness can heavily influence the biological response of HGF-1. CONCLUSIONS: Surfaces wettability as well as cellular behavior seem to be affected by the selection of the finishing system used to lastly shape the restoration. Especially, the presence of OIL act as a negative factor in the regards of human gingival fibroblasts. The present study may provide the first clinical instruction regarding the best polishing system of composite material when the restoration is placed directly in contact with soft tissue cells. Understanding HGF-1 behavior can help identifying the polishing treatment for direct restoration of carious/non-carious cervical lesions associated with gingival recessions.


Subject(s)
Composite Resins , Dental Polishing , Fibroblasts , Gingiva , Surface Properties , Humans , Gingiva/cytology , Dental Polishing/methods , Microscopy, Electron, Scanning , Cell Proliferation , Wettability , Dental Restoration, Permanent/methods , Tungsten Compounds/pharmacology , Cells, Cultured
5.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38902697

ABSTRACT

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Subject(s)
Aluminum Oxide , Coffee , Color , Composite Resins , Dental Polishing , Surface Properties , Composite Resins/chemistry , Dental Polishing/methods , Aluminum Oxide/chemistry , Materials Testing , Spectrophotometry , In Vitro Techniques , Humans , Diamond/chemistry , Nanocomposites/chemistry , Tooth Bleaching Agents/chemistry , Water/chemistry , Dental Materials/chemistry , Time Factors
6.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38857196

ABSTRACT

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Subject(s)
Dental Materials , Dental Polishing , Steam , Sterilization , Surface Properties , Zirconium , Sterilization/methods , Humans , Dental Polishing/methods , Materials Testing/methods , Dental Restoration, Permanent/methods , Microscopy, Electron, Scanning/methods
7.
Clin Exp Dent Res ; 10(3): e884, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38798053

ABSTRACT

OBJECTIVES: This study compared the effects of glazing versus polishing on mechanical, optical, and surface properties of zirconia ceramics with different translucencies. MATERIALS AND METHODS: In this in vitro study, 120 bar-shaped specimens (25 × 4 × 1.2 mm) were fabricated from three different types of zirconia with different translucencies (n = 40, DD Bio ZW, ZX2, and Cube X2). After sintering, each zirconia group was randomly divided into five subgroups of control (glazing), glazing + bur abrasion, glazing + bur abrasion + polishing with EVE Diacera® kit, glazing + bur abrasion + reglazing, and glazing + bur abrasion + polishing with EVE Diacera® kit + reglazing. The specimens underwent surface roughness, hardness, flexural strength, and translucency tests, as well as X-ray diffraction (XRD) and scanning electron microscopy (SEM) for assessment of surface topography. Data were analyzed by one-way analysis of variance, Tukey test, and Pearson test (α = .05). RESULTS: Flexural strength, surface hardness, and translucency were significantly correlated with zirconia type. ZW zirconia had significantly higher flexural strength and surface hardness and significantly lower translucency than Cube X2 and ZX2 (p < .001). Surface roughness had no significant correlation with zirconia type (p = .274). Polishing created the smoothest, and bur abrasion created the roughest surface (p < .001). Flexural strength and hardness in most experimental groups were significantly lower than in the control group (p < .001). Translucency was not significantly different in bur abrasion and polishing groups, compared with the control group; however, reglazing significantly increased the translucency (p < .001). SEM micrographs confirmed the surface roughness results. XRD showed monoclinic phase only in reglazed groups. CONCLUSION: Of different surface treatments, polishing improved the surface properties and caused the smallest change in mechanical properties of zirconia with different translucencies.


Subject(s)
Ceramics , Dental Polishing , Materials Testing , Microscopy, Electron, Scanning , Surface Properties , Zirconium , Zirconium/chemistry , Dental Polishing/methods , Ceramics/chemistry , Hardness , Dental Materials/chemistry , Flexural Strength , X-Ray Diffraction , In Vitro Techniques
8.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741081

ABSTRACT

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Subject(s)
Biofilms , Dental Implants , Plasma Gases , Surface Properties , Titanium , Biofilms/drug effects , Titanium/chemistry , Dental Implants/microbiology , Dental Polishing/methods , Glycine , Humans , In Vitro Techniques , Microscopy, Electron, Scanning , Nickel
9.
Am J Dent ; 37(2): 66-70, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38704848

ABSTRACT

PURPOSE: To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation. METHODS: 160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al2O3-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al2O3-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests. RESULTS: There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS. CLINICAL SIGNIFICANCE: As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al2O3-impregnated discs had the smoothest surfaces.


Subject(s)
Aluminum Oxide , Composite Resins , Dental Polishing , Saliva, Artificial , Silicon Compounds , Surface Properties , Composite Resins/chemistry , Dental Polishing/methods , Humans , Saliva, Artificial/chemistry , Hydrogen-Ion Concentration , Aluminum Oxide/chemistry , Silicon Compounds/chemistry , Carbon Compounds, Inorganic/chemistry , Materials Testing , Nanocomposites/chemistry , Citric Acid/chemistry , Saliva/enzymology , Saliva/metabolism , Saliva/chemistry , Tooth Erosion , Rubber/chemistry , Dental Materials/chemistry
10.
Am J Dent ; 37(2): 101-105, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38704853

ABSTRACT

PURPOSE: To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE00), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing. METHODS: Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE00 and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE00 and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05). RESULTS: The ΔE00 values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP. CLINICAL SIGNIFICANCE: Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.


Subject(s)
Dentifrices , Surface Properties , Toothbrushing , Zirconium , Zirconium/chemistry , Dentifrices/therapeutic use , Color , Tooth Bleaching Agents/therapeutic use , Dental Polishing/methods , Yttrium/chemistry , Humans , Materials Testing , Tooth Bleaching/methods , Spectrophotometry , Microscopy, Confocal
11.
BMC Oral Health ; 24(1): 609, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38796434

ABSTRACT

BACKGROUND: High speed electric handpieces have recently been growing in popularity among dental professionals. Advantages include smoother surface preparation and increased cutting efficiency. AIM: The primary objective was to compare enamel surface roughness following resin cleanup after bracket debonding using highspeed air turbine versus electric handpiece. The secondary objective was to record the time needed for resin-clean up. METHOD: Forty deidentified freshly extracted human premolars were cleaned and sectioned at the cement-enamel junction. The crowns were embedded in acrylic blocks. Enamel surface roughness parameters (Ra, Rz, Rp and Rv) were measured using a stylus profilometer. Brackets were bonded using a light-cure orthodontic adhesive and stored in distilled water for 24 h. Following bracket debonding, the specimens were randomly divided into 2 groups: First group: resin clean-up was carried out using a 12-fluted carbide bur mounted on a high-speed air turbine; and second group: where an electric handpiece was used. Surface roughness parameters were measured following resin clean up and after polishing using pumice and a rubber cup. Time needed for resin clean-up was recorded. Differences in enamel surface roughness and time between groups were compared using repeated measures ANOVA and independent samples t-test, respectively at P ≤ 0.05. RESULTS: The electric handpiece groups showed significantly higher values for Ra, Rz and Rp both following resin cleanup and polishing. Time taken for resin cleanup was significantly longer for the electric handpiece group. CONCLUSION: Considering both surface roughness and time, electric handpiece do not seem to add greater effectiveness or efficiency to resin cleanup following orthodontic bracket debonding.


Subject(s)
Dental Debonding , Dental Enamel , Dental High-Speed Equipment , Surface Properties , Humans , Dental Debonding/methods , In Vitro Techniques , Resin Cements/chemistry , Orthodontic Brackets , Time Factors , Bicuspid , Dental Polishing/methods
12.
J Dent ; 146: 105101, 2024 07.
Article in English | MEDLINE | ID: mdl-38801940

ABSTRACT

OBJECTIVE: To evaluate the effect of polishing and layering thickness on the wear resistance of 3D-printed occlusal splint materials. METHODS: Specimens with 3 different layer thicknesses (50, 75, 100 µm) were produced in the form of a disc 3 mm thick using V-Print splint resin on a 3D-printer with digital light processing technology. (n = 16 for each thickness) All specimens were washed and cured according to the manufacturer's instructions. Half of the specimens of each layer thickness were polished with silicon carbide papers. All specimens were subjected to 120.000 cycles of a chewing simulator for 2-body wear tests. Before and after the wear test, the specimens were scanned with a laser scanner, and the images were overlaid using a 3D analysis program and the volume loss was calculated. The wear patterns of the specimens were examined under a scanning electron microscope. Statistical evaluation was performed using a Shapiro-Wilk test, 2-way ANOVA, 1-way ANOVA, and Tukey post hoc test (α = 0.05). RESULTS: While polishing had a significant effect (p = 0.003) on the wear volume of the occlusal splints, layer thickness (p = 0.105) and their interaction between polishing and layer thickness (p = 0.620) did not significantly affect the wear volume. Regardless of the polishing, the lowest mean wear was observed for D50 (0.064 mm3), followed by D75 (0.078 mm3), and D100 (0.096 mm3). However, a significant difference was observed only between polished D50 and unpolished D100. CONCLUSION: The polished 3D-printed occlusal splint resin showed higher wear resistance than the unpolished one, regardless of the layer thickness. CLINICAL SIGNIFICANCE: Since different layer thicknesses of 50 µm and greater had no effect on the wear resistance of the material, a layer thickness of 100 µm may be preferred for faster printing. However, polishing occlusal splints may reduce the amount of wear and improve clinical performance.


Subject(s)
Dental Polishing , Materials Testing , Microscopy, Electron, Scanning , Occlusal Splints , Printing, Three-Dimensional , Surface Properties , Dental Polishing/methods , Humans , Carbon Compounds, Inorganic/chemistry , Silicon Compounds/chemistry , Dental Restoration Wear , Lasers , Dental Materials/chemistry , Computer-Aided Design , Mastication/physiology
13.
Niger J Clin Pract ; 27(4): 496-503, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38679773

ABSTRACT

BACKGROUND: Monolithic zirconia restorations can be produced from self-colored or uncolored blocks. The coloring procedure of uncolored blocks and surface treatments may affect the appearance of the restoration. AIM: The purpose of this study is to evaluate the effect of liquid coloring and surface treatments on optical properties of translucent monolithic zirconia. METHODS: All specimens were cut from zirconia blocks with a thickness of 1 mm. Specimens were dipped in the coloring liquids for 3 min, 5 min, and 7 min and then divided into groups of 10 specimens for surface treatments. Glaze and mechanical polishing were applied, and the color of the specimens was measured under the D65 lighting condition with a spectrophotometer device. Color values obtained from the CIE Lab formula and the translucency parameter (TP), opalescence parameter (OP), and contrast ratio (CR) were calculated. The normality of the data was confirmed with the Shapiro-Wilk test. A three-way analysis of variance (ANOVA) was used to assess the effect of dipping time, liquid shade, and surface treatments. RESULTS: The effect of liquid shade and dipping time on the TP, OP, and CR parameters were statistically significant, and the TP values were reduced with the application of coloring liquid. Mechanical polishing groups had higher OP values and lower TP values than glazed groups. CONCLUSION: In cases where high translucency is required, it may be advisable to use self-colored blocks and apply glaze as a surface treatment to achieve the desired optical properties.


Subject(s)
Surface Properties , Zirconium , Zirconium/chemistry , Humans , Materials Testing , Color , Spectrophotometry , Dental Materials/chemistry , Time Factors , Coloring Agents , Dental Polishing/methods
14.
J Dent ; 144: 104918, 2024 05.
Article in English | MEDLINE | ID: mdl-38461887

ABSTRACT

OBJECTIVE: To determine the effect of airborne particle abrasion (APA) on micro-tensile bond strength (µTBS) to dentin using different air-abrasion/polishing powders. METHODS: The bonding effectiveness of G2 Bond Universal (G2B), used in etch-and-rinse (E&R) and self-etch mode (SE), was tested on bur-cut dentin and dentin air abraded/polished using six different powders (aluminum oxide 29 µm (AO29) and 53 µm (AO53), aluminum trihydroxide (AT), sodium bicarbonate (SB), sodium bicarbonate soft (SBsoft) and bioactive glass (BG); Velopex). Adhesive-composite resin specimens were immersed in distilled water at 37 °C for one week and cut into microspecimens. Half of the specimens were subjected to 50,000 thermocycles (aged). Immediate and aged µTBS to dentin were measured. Statistical analysis was performed using linear mixed-effects (LME) modeling (p < 0.05). RESULTS: Comparing the aged bond strengths to air-abraded/polished dentin with bur-cut dentin, pretreatment with SB and SBsoft in combination with G2B used in E&R mode, and BG air polishing in combination with both application modes (E&R, SE), resulted in a significantly higher bond strength. Dentin bond strength was only significantly lower when air abraded with AO29 and using G2B in SE mode. Aging did not significantly influence bond strength for both application modes (E&R, SE), except for AO29 and AT-treated dentin, where bond strengths decrea sed significantly using G2B in SE mode. In general, G2B reached significantly higher bond strengths on air-abraded/polished dentin in E&R mode than in SE mode. CONCLUSION: Air-abrasion/polishing did not impair dentin bond strength using G2B, except when dentin was air abraded with AO29 and using G2B in SE mode. Air polishing positively influenced the bond strength to dentin in specific groups. CLINICAL SIGNIFICANCE: APA is safe concerning bonding to dentin. The E&R application mode is preferred using G2B as adhesive on air-abraded/polished dentin. Air polishing with BG positively influenced dentin bond strength for both application methods.


Subject(s)
Air Abrasion, Dental , Composite Resins , Dental Bonding , Dentin-Bonding Agents , Dentin , Materials Testing , Resin Cements , Surface Properties , Tensile Strength , Dental Bonding/methods , Humans , Composite Resins/chemistry , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dental Stress Analysis , Acid Etching, Dental/methods , Dental Polishing/methods , Stress, Mechanical , Dental Materials/chemistry , Powders
15.
São Paulo; s.n; 20240222. 119 p.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1531857

ABSTRACT

Objetivos: O estudo avaliou, para quatro diferentes zircônias monolíticas translúcidas, o efeito da microestrutura e do estado da superfície (glazeada versus polida após simulação de ajuste oclusal) nas seguintes respostas: (1) propriedades mecânicas (resistência a flexão biaxial, tenacidade à fratura e dureza Vickers; (2) molhamento de superfície a partir da verificação do ângulo de contato; (3) perda de volume e rugosidade superficial após ensaio de desgaste e (4) parâmetros de translucidez. Materiais e métodos: quatro diferentes blocos de zircônias translúcidas foram utilizadas nesse estudo; Prettau anterior, Lava Plus, Cercon hT e Cercon xT. Foram confeccionados 112 espécimes em formato de disco para cada material, tendo sido todos eles glazeados e parte dos espécimes foram ajustados superficialmente com o uso de pontas diamantadas (simulação de ajuste oclusal) e posteriormente polidos com o uso de ponta de borrachas (simulação de polimento clínico). Os espécimes utilizados nos ensaios de dureza Vickers e tenacidade à fratura foram polidos com o uso de lixas e soluções diamantadas em politriz semiautomática. Parte dos espécimes confeccionados sofreram o ensaio de desgaste. Anteriormente, foram levados a um perfilômetro óptico para determinação de seu perfil topográfico para a determinação da rugosidade e posterior avaliação da perda de volume. Em seguida, os discos foram submetidos ao ensaio de desgaste em uma simuladora da mastigação por meio milhão de ciclos com carga de 30 N e frequência de 2 Hz. Após o ensaio de desgaste, os espécimes foram submetidos novamente à análise topográfica através de perfilometria óptica para determinação da perda de volume e rugosidade superficial. Foram avaliadas também as propriedades mecânicas por meio dos ensaios de resistência a flexão biaxial, tenacidade a fratura e dureza Vickers, e a análise de molhamento de superfície por meio da mensuração do ângulo de contato e caracterização das propriedades de ópticas sobre os parâmetros de translucidez. Resultados: na resistência á flexão foi verificado o efeito do estado da superfície, na condição ajuste Cercon hT apresentou o maior valor e o Lava Plus o menor, para a condição glaze não foi encontrada diferença entre os valores de resistência os materiais testados; os valores médios de dureza foram semelhantes para os materiais testados; as médias de tenacidade à fratura foram significativamente diferentes Lava Plus apresentou o maior valor e o Cercon hT e Prettau o menor que foram semelhantes entre si; para os valores de ângulo de contato foram estatisticamente superiores na condição ajuste para todos os materiais; para os valores médios de rugosidade média foi verificado o efeito do ajuste e posterior polimento para o Cercon hT, após ensaio de desgaste foi verificado o aumento da rugosidade para todos os materiais independente da condição, os valores de Ra para a condição ajuste foi numericamente maior se comparada a condição glaze para todos os materiais, os valores médios de perda de volume após ensaio de desgaste foi significativamente maior para o Lava Plus na condição ajuste, para os demais materiais o estado as superfície não afetou significativamente a perda de volume, para os valores do parâmetro de translucidez os materiais Lava Plus e Prettau tiveram valores menores semelhantes e significativos aos valores de Cercon hT e xT que foram superiores e semelhante entre si, na condição ajuste os materiais Cercon hT e Cercon xT continuaram apresentando valores semelhantes e superiores a Prettau, o Lava Plus após ajuste apresentou valores semelhantes estatisticamente aos valores de PT dos materiais Cercon xT e hT o material Cercon hT apresentou maior valor de resistência após ajuste Conclusão: Houve efeito da microestrutura e do estado de superfície para a resistência à flexão, rugosidade média e para o parâmetro de translucidez; o efeito da microestrutura na tenacidade à fratura, e foi observado o efeito do estado de superfície para os valores do ângulo de contato e na perda de volume.


Subject(s)
Dental Polishing
16.
PLoS One ; 19(2): e0286672, 2024.
Article in English | MEDLINE | ID: mdl-38408064

ABSTRACT

This ex vivo study aimed to investigate surface roughness and substance loss after treatment with different professional cleaning methods and to determine whether subsequent polishing with a rubber cup and polishing paste is necessary. Samples (flat and natural surfaces) of human enamel and dentin were prepared (baseline) and treated with either a curette, air-polishing with erythritol, a rubber cup and polishing paste, or a combination thereof (treatment). Subsequently, all samples were immersed in an ultrasonic bath (ultrasonic) to remove residues from the treatment procedures. The surface roughness values sRa and sRz as well as tissue loss were measured profilometrically. Linear regression models were used to compare group differences (roughness and loss) considering the corresponding baseline value. The significance level was set at p<0.05. sRa increased significantly after treatment with curettes or air-polishing with erythritol in both enamel (p<0.001) and dentin (p<0.001) of flat samples. The same effect was observed for sRz in dentin (p<0.001) but not for enamel compared to negative control. Polishing with a rubber cup and paste alone had no significant effect on roughness values. When combined with other treatments, the effect of curette or air-polishing with erythritol dominated the effect. In enamel, none of the tested methods led to measurable tissue loss. In dentin, air-polishing with erythritol caused ≤50% tissue loss compared to the curette. Conclusively, for enamel, treatment effects on roughness were measurable but of limited clinical relevance. For dentin, air-polishing resulted in a smaller but insignificant roughness increase and less tissue loss compared to the curette. Polishing with a rubber cup and paste did not affect surface roughness. Regarding the clinical application, the use of air-polishing seems to be a less invasive procedure than using a curette; polishing with rubber cup and paste offers no advantage in terms of reducing roughness as a final procedure.


Subject(s)
Erythritol , Rubber , Humans , Surface Properties , Dental Polishing
17.
Int J Oral Maxillofac Implants ; 39(1): 87-98, 2024 02 27.
Article in English | MEDLINE | ID: mdl-38416003

ABSTRACT

PURPOSE: To investigate the possible antimicrobial activity of glycine air polishing by comparing peri-implant microbiota before and after treatment. MATERIALS AND METHODS: A total of 15 patients who received implant-supported full-arch fixed rehabilitations were included. After prosthesis removal (T0), Plaque Index (PI), probing depth (PD), and bleeding on probing (BOP) were recorded. In each hemiarch, the implant with the highest PD score was selected for microbiologic sample collection from the peri-implant sulcus (T0). All patients received two different hygienic protocols (randomly administered, one per each hemiarch): glycine air-polishing (G) and cleansing with cotton pellets soaked in saline (C). At 7 days (T1) and 3 months (T2) after the intervention, PI and BOP were recorded, and new microbiologic samples were taken. Traditional polymerase chain reaction (PCR) and quantitative PCR real-time were employed for microbiologic analysis to investigate how the presence of different bacterial species varied according to the hygienic treatment performed. RESULTS: Treatment G provided a significantly higher PI score reduction around implants compared to treatment C (P = .015). No statistical difference was found in the microbial population around G and C implant sites, with Tannerella forsythia being the most commonly detected bacterial species in both G and C groups. No statistical differences were found between the antimicrobial activity of treatments C and G. CONCLUSIONS: Glycine powder air polishing is a valid method for professional hygienic care of implants and was more effective in PI reduction compared to the control treatment. However, its antimicrobial efficacy cannot be confirmed by the outcomes of the present study.


Subject(s)
Dental Implants , Dental Polishing , Humans , Mouth , Face , Glycine/therapeutic use
18.
Clin Implant Dent Relat Res ; 26(2): 415-426, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38317375

ABSTRACT

INTRODUCTION: To evaluate the adjunctive effect of glycine-powder air-polishing (GPAP) to full-mouth ultrasonic debridement (Fm-UD) in the treatment of peri-implant mucositis, and to determine the impact of implant and patient-level variables for disease resolution. METHODS: Individuals with a diagnosis of peri-implant mucositis were consecutively included in this randomized parallel arm clinical study. All the participants received a session of Fm-UD. Only implants allocated to the test group were additionally treated with GPAP. Clinical assessments were recorded at baseline, at 3 and at 12 months following intervention. The primary outcomes were complete disease resolution (DR1), defined as absence of bleeding sites at probing per implants, and partial disease resolution (DR2), measured as the presence of less than two bleeding sites at probing per implant. A final logistic multivariate regression model was built to evaluate the predictive role of implant and patient-level variables on DR. RESULTS: Fifty two patients and 157 implants were included. Both groups displayed significant reduction in the extent of bleeding on probing and plaque levels. At 12 months, DR1 was achieved in 16% and 27% of participants for the test and the control group respectively. IDR1 was best predicted by the number of bleeding sites (OR = 2.7, p = 0.04) and the greatest PPD value (OR = 2.7, p = 0.05), while IDR2 by the prosthetic connection (OR = 2.59, p = 0.02), the mean PPD (OR = 2.23, p = 0.04), the FMBS (OR = 4.09, p = 0.04), and number of implants (OR = 4.59, p = 0.02). CONCLUSIONS: Despite significant improvements of clinical signs of peri-implant inflammation, the use of GPAP appears to have no adjunctive effect as compared with Fm-UD alone in the achievement of DR. Elevated initial levels of bleeding and PD predicted inferior likelihood of reaching disease resolution. The present randomized parallel arm clinical study was registered on Clinicaltrials.gov and received the following registration number: NCT05801315. This clinical trial was not registered prior to participant recruitment and randomization (https://register. CLINICALTRIALS: gov/prs/app/action/SelectProtocol?sid=S0009965&selectaction=Edit&uid=U0004FXM&ts=2&cx=fje7l8).


Subject(s)
Dental Implants , Mucositis , Peri-Implantitis , Humans , Glycine/therapeutic use , Powders , Dental Implants/adverse effects , Dental Polishing , Treatment Outcome , Peri-Implantitis/drug therapy , Biofilms
19.
BMC Oral Health ; 24(1): 197, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38326838

ABSTRACT

BACKGROUND: Recently, universal single-shade resin composites have become increasingly available in the dental market. The modification of their composition can have an inadvertent effect on their physical and surface properties, and subsequently determinantal effect on their clinical function and longevity. Therefore, this study aimed to evaluate the effect of different finishing and polishing (F/P) systems on surface roughness (Ra), surface gloss (GU), and Vickers microhardness (VMH) of universal single-shade RBCs. MATERIALS AND METHODS: Four commercial RBCs were used; the universal single-shade RBCs were Omnichroma, Charisma® Diamond ONE, and Vittra APS Unique, and a conventional nanocomposite Filtek™ Z250 XT was used as a control. The 3 F/P systems were Sof-Lex™ XT, Enhance®/PoGo®, and Diacomp® Plus Twist. A total of 160 discs were used for the 3 F/P system groups for all RBCs (n = 10). After F/P, the Ra, GU, and VMH were assessed. The data were analyzed using 2-way ANOVA at p-value < 0.05. RESULTS: Significant differences were found among the four RBCs and the 3 F/P systems (p < .000). Omnichroma showed the lowest Ra and acceptable GU, but the lowest VMH. Charisma showed the highest Ra, acceptable GU, and VMH. Vittra showed acceptable Ra, GU, and VMH and Filtek showed the highest GU, VMH, and acceptable Ra. CONCLUSION: Although conventional nanohybrid RBC (Filtek Z250 XT) showed better GU and VMH values, the universal single-shade RBCs demonstrated comparable surface properties. The highest GU & VMH and lowest Ra were achieved by Diacomp followed by Enhance and Soflex.


Subject(s)
Composite Resins , Dental Polishing , Humans , Materials Testing , Dental Materials , Diamond , Surface Properties
20.
BMC Oral Health ; 24(1): 287, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38419033

ABSTRACT

BACKGROUND: As superior esthetic is one of the main reasons for using composite resins, it is very important to be familiar with factors and techniques affecting their optical properties and appearance. AIM: The aim of this study was comparing the effect of finishing and polishing with and without water coolant, on the color change and opacity of composite resin materials. METHODS: Composites used for preparing samples were Z250 (microhybrid), Z350XT (nanofilled), and Z550 (nanohybrid). Then divided into 4 groups of 5 depending on finishing and polishing technique (dry or wet) and time (immediate and after twenty-four hours). After polishing, samples were assessed using a spectrophotometer. Color change and opacity were determined. Data was analyzed using Kolmogorov-Smirnov, ANOVA and Tukey HSD tests. RESULTS: Type of material at both time had a significant effect on ΔE and opacity. Our results in dry and wet technique immediately(T0) showed that the highest and lowest ΔE and opacity belong to Z350XT (p < 0.001). After Twenty-four hours (T24), opacity of Z250 in wet condition was higher than dry condition (p < 0.001). CONCLUSIONS: Wet or dry technique was only effective on color in immediate polishing. Regarding opacity, technique was only effective in case of delayed polishing.


Subject(s)
Composite Resins , Dental Polishing , Humans , Color , Dental Polishing/methods , Materials Testing , Surface Properties , Composite Resins/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...