Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.136
Filter
1.
J Esthet Restor Dent ; 36(11): 1547-1556, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39095320

ABSTRACT

OBJECTIVE: To evaluate the fracture behavior of human molars with extensive MOD restorations using short-fiber-reinforced resin composite of varying viscosities. MATERIALS AND METHODS: Human molars were randomly divided into seven groups (n = 12): intact teeth (control); restoration using conventional high-viscosity resin composite without (Filtek Z350XT, 3M) or with fibers (everX Posterior, GC); conventional low-viscosity resin composite without (Filtek Supreme Flowable, 3M) or with fibers (everX Flow Dentin Shade, GC); bulk-fill low-viscosity resin composite (Filtek Bulk Fill Flow, 3M) or with fibers (everX Flow Bulk Shade, GC). Restorations were performed on extensive MOD preparations, following the manufacturers' recommendations for each material. Specimens underwent fracture strength testing (N) and fracture pattern (%) categorized as repairable, possibly repairable, or non-repairable. Results were analyzed using a generalized linear model (N) and Fisher's exact test (%), with α = 0.05. RESULTS: Restorations performed with high-viscosity materials showed fracture strength values similar to the control and higher than those of restorations using low-viscosity resin composites (p < 0.0001), except for the bulk-fill low-viscosity resin composite with fibers (p > 0.05). Teeth restored using low-viscosity resin composite with fibers showed a higher % of repairable and possibly repairable fractures than the control (p = 0.0091). CONCLUSIONS: The viscosity of materials mediated the fracture strength, with restorations using high-viscosity resin composites promoting values similar to the intact tooth; however, the presence of fibers influenced the fracture pattern. CLINICAL SIGNIFICANCE: Teeth with MOD cavities restored with high-viscosity resin composites showed similar fracture strength to intact teeth. Fiber-reinforced low-viscosity resin composite for the base of restoration resulted in a more repairable/possibly repairable fracture pattern.


Subject(s)
Composite Resins , Molar , Composite Resins/chemistry , Humans , Viscosity , Dental Restoration Failure , Dental Restoration, Permanent/methods , Dental Stress Analysis , Materials Testing , Tooth Fractures/therapy
2.
BMC Oral Health ; 24(1): 871, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090743

ABSTRACT

BACKGROUND: The aim of this research was to analyse the current literature on displaced dental implants in the mandibular body, including local and systemic variables related to their cause, and to identify the most frequent location. METHODS: The study conducted a search of three databases (Pubmed, Scopus, and Web of Science) using specific index terms such as 'dental implant', 'displacement', 'dislocation', 'displaced', and 'mandible'. The analysis focused on the direction of displacement and the characteristics of the bone tissue (bone quality, density, and quantity) in cases where dental implants were displaced. RESULTS: A total of 371 articles were obtained. Thirteen of these articles were selected and read in full. To define bone quality, the Lekholm and Zarb classification, modified by Rosas et al., was used. The type II-B bone, which is characterized by thick cortical bone surrounding cancellous bone with extremely wide medullary spaces, presented the largest number of complications. Twenty-two cases were found in which the displacement direction was horizontal. Of these, four were displaced vestibularly, fourteen lingually, and four remained in the center. Additionally, 24 cases presented vertical displacement, with 12 displaced towards the inferior border of the mandible, 9 towards the middle or adjacent to the inferior dental nerve canal, and 3 above the inferior dental nerve canal. CONCLUSION: The accidental displacement of implants within the mandibular body is associated with various risk factors, including the characteristics of the bony trabeculum and the size of the medullary spaces. It is reasonable to suggest that only an adequate pre-surgical diagnostic evaluation, with the help of high-resolution tomographic images that allow a previous evaluation of these structures, will help to have better control over the other factors, thus minimizing the risk of displacement.


Subject(s)
Dental Implants , Mandible , Humans , Dental Implants/adverse effects , Mandible/diagnostic imaging , Risk Factors , Foreign-Body Migration/prevention & control , Foreign-Body Migration/etiology , Bone Density , Dental Restoration Failure
3.
J Dent ; 148: 105242, 2024 09.
Article in English | MEDLINE | ID: mdl-39009334

ABSTRACT

OBJECTIVE: To investigate fatigue methods for the evaluation of translucent zirconia and to associate in vitro failures with clinically reported ones. DATA: Studies published in English that used fatigue tests on dental translucent zirconia. SOURCES: Two databases (MEDLINE/PubMed and Scopus) were electronically searched without any restriction on year of publication. STUDY SELECTION: A total of 4555 studies were identified. After removal of duplicates (78) and irrelevant articles (4316) that did not meet the inclusion criteria, 161 articles were considered eligible based on their titles and abstracts. These articles were fully read, leading to the inclusion of 41 studies in the review. RESULTS: The most widely used fatigue method for evaluation of translucent zirconia was step-stress (18 articles), followed by staircase (seven articles), and step-wise (two articles). Most studies had been conducted in a wet environment with the use of a stainless steel piston to apply load to cemented structures on a dentin-like substrate. Most fracture analyses indicated the fracture originated on the cementation or contact surface where the load was applied. Moreover, studies that utilized anatomical structures (dental crowns) reported fractures starting at the cervical margin of the crowns. CONCLUSION: Most studies used the step-stress method. Only three studies reported failures similar to those found in clinical trials that used translucent zirconia restorations. CLINICAL SIGNIFICANCE: The study findings can assist on correlating clinical failures to the ones observed in vitro.


Subject(s)
Dental Materials , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Zirconium , Zirconium/chemistry , Humans , Dental Materials/chemistry , Crowns , Surface Properties , Stress, Mechanical
4.
Oper Dent ; 49(4): 455-464, 2024 07 01.
Article in English | MEDLINE | ID: mdl-38978307

ABSTRACT

OBJECTIVE: To evaluate the effect of polyethylene fiber-reinforcement on the fracture resistance and fracture mode of extensive resin-based composite (RBC) restorations in structurally compromised maxillary premolars. METHODS AND MATERIALS: Maxillary premolars (54) with specific dimensions and extracted for orthodontic reasons were used. Following mesio-occluso-distal (MOD) cavity preparation and endodontic access, teeth were randomly assigned to one of three restorative protocols (n=18): RBC applied incrementally (I) or reinforced with woven polyethylene fibers (Ribbond) placed horizontally (H) or U-shaped (U). Restored teeth were stored for 45 days in distilled water at 37°C and then loaded monotonically until fracture. Half of the specimens in each group received axial loading (A) and the other half was loaded paraxially (PA). Fracture load data was assessed using two-way analysis of variance and Tukey's post hoc test for multiple comparisons (α=0.05). The fracture initiation and propagation path were analyzed using stereomicroscopy and scanning-electron microscopy. RESULTS: No significant differences were observed for the fracture strength among loading configurations, except for groups IA (825 N) and HA (553 N). Fracture initiated and propagated mainly at and through the RBC restoration in the I group, whereas a shift to the interface was observed in both polyethylene fiber-reinforced groups. Blocking and bridging of cracks were identified around the fibers, especially in specimens of group U. CONCLUSIONS: Incorporation of woven polyethylene fibers to reinforce extensive MOD resin-based composite restorations on endodontically treated premolars reduced the occurrence of cohesive fractures in the restorative material but was unable to increase the fracture resistance of the affected teeth.


Subject(s)
Bicuspid , Composite Resins , Dental Restoration Failure , Dental Restoration, Permanent , Dental Stress Analysis , Humans , Composite Resins/therapeutic use , Composite Resins/chemistry , In Vitro Techniques , Dental Restoration, Permanent/methods , Polyethylene/chemistry , Polyethylene/therapeutic use , Microscopy, Electron, Scanning , Materials Testing , Tooth Fractures/prevention & control , Tooth, Nonvital/therapy , Polyethylenes
5.
J Dent ; 149: 105266, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39067651

ABSTRACT

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Denture Retention , Denture, Overlay , Titanium , Zirconium , Humans , Female , Male , Middle Aged , Follow-Up Studies , Prospective Studies , Denture Retention/instrumentation , Aged , Treatment Outcome , Mandible/surgery , Denture Design , Denture Repair , Denture, Complete, Lower
6.
Dent Mater ; 40(9): 1332-1340, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38876825

ABSTRACT

OBJECTIVES: To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue. METHODS: Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 106 cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9). RESULTS: All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (m = 1.0; 0.7, 1.4) for 1PA than for 2PA (m = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens. SIGNIFICANCE: 1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.


Subject(s)
Cone-Beam Computed Tomography , Dental Abutments , Dental Implant-Abutment Design , Dental Restoration Failure , Dental Stress Analysis , Torque , Dental Implants , Materials Testing
7.
Clin Oral Investig ; 28(7): 380, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38886209

ABSTRACT

OBJECTIVE: To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS: Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS: The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION: The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE: These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.


Subject(s)
Ceramics , Dental Prosthesis Design , Humans , Prospective Studies , Male , Female , Middle Aged , Ceramics/chemistry , Treatment Outcome , Adult , Patient Satisfaction , Aged , Esthetics, Dental , Alveolar Bone Loss/diagnostic imaging , Tooth Socket/surgery , Tooth Socket/diagnostic imaging , Dental Restoration Failure , Dental Implants
8.
Acta Odontol Latinoam ; 37(1): 88-95, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38920130

ABSTRACT

Glass ceramics are widely used to manufacture esthetic veneers, inlays, onlays, and crowns. Although the clinical survival rates ofglass-ceramic restorations arefavorable,fractures or chips are common. Certain cases can be repaired with direct composite. AIM: The aim of this study was to investigate the interaction effect of different designs and surface treatments on the load-to-failure of lithium disilicate glass-ceramic repaired with nanofilled composite. MATERIALS AND METHOD: Lithium-disilicate glass-ceramic slabs (IPS e.max Press, Ivoclar Vivadent) with three different designs of the top surface (flat, single plateau, or doubleplateau) (n=U) received 'no treatment', '5% HF etching', or "AI2O3 sandblasting". HF-etched and sandblasted slabs also received silane and universal one-step adhesive application. All slabs were incrementally repaired with nanofilled composite (Filtek Z350, 3M ESPE) up to6 mm above the highest ceramic top plateau. Specimens were stored in artificial saliva at 37 °C for 21 days and then subjected to 1,000 thermocycles between 5 and 55 °C. The interface composite-ceramic of each specimen was tensile tested until failure in a universal testing machine and the mode of failure was determined under a stereomicroscope. The ceramic surface morphology of one representative tested specimen from each subgroup (design/surface treatment) was observed through scanning electron microscopy (SEM). RESULTS: Regardless of ceramic design, the absence of surface treatment resulted in significantly lower load-to-failure values. No significant differences in load-to-failure values were observed between HF-etched and sandblasted specimens for the flat design; however, HF etching resulted in significantly higher load-to-failure values than sandblasting for both single plateau and double plateau designs. The majority (60%) of HF-etched specimens with single plateau or double plateau presented mixed failures. SEM photomicrographs showed that HF-etched specimens had smoother surfaces than sandblasted specimens. CONCLUSION: The surface treatment of a defective lithium disilicate glass-ceramic restoration has more influence than its macroscopic design on the retention of the composite repair. HF etching seems to provide higher bond strength to the composite repair.


Embora fraturas e lascamento de restauragoes vitrocerámicas sejam comuns, alguns casos podem ser reparados com compósito direto. OBJETIVO: investigar o efeito da interagao de diferentes formas e tratamentos de superficie na carga de ruptura de uma vitrocerámica reforgada com dissilicato de litio reparada com compósito nanoparticulado. MATERIAIS E MÉTODOS: A superficie superior de espécimes de vitroceramica (IPS e.max Press, Ivoclar Vivadent) foi preparada com tres formas (plana, plato único, ou duplo) e recebeu (n=11): 'nenhum tratamento', 'condicionamento com ácido hidrofluoridrico 5%', ou 'jateamento com AfOf. Ambos espécimes condicionados e jateados receberam silano e adesivo universal. Todos os espécimes foram reparados incrementalmente com compósito (Filtek Z350, 3M ESPE) até6 mm acima do plato cerámico mais alto, armazenados em saliva artificial á 37 °C por 21 dias, e submetidos á 1.000 termociclos (5 e 55 °C). A interface compósito-cerámica de cada amostra foi testada á tragao até sua falha em máquina universal e o modo de falha foi determinado com estereomicroscópio. A morfologia da superficie de uma amostra representativa de forma/tratamento de superficie foi observada através de microscopia eletronica de varredura (MEV). RESULTADOS: Independentemente da forma ceramica, a ausencia de tratamento superficial resultou em valores de carga de ruptura significativamente menores. Nao foi observada differenga significativa entre os espécimes planos condicionados ou jateados; no entanto, o condicionamento resultou em valores significativamente maiores que o jateamento para espécimes com plato único e duplo. A maioria (60%) dos espécimes condicionados e com plato único ou duplo apresentou falhas mistas. Imagens SEM demonstraram rugosidade superficial mais regular dos espécimes condicionados que os jateados. CONCLUSÕES: O tratamento superficial de uma restauragao defeituosa de vitrocerámica reforgada por dissilicato de litio tem maior influencia na retengao do reparo de compósito do que sua forma macroscópica; ainda, o condicionamento com ácido hidrofluoridrico parece proporcionar maior resistencia de uniao ao reparo com compósito.


Subject(s)
Ceramics , Dental Porcelain , Surface Properties , Ceramics/chemistry , Dental Porcelain/chemistry , Materials Testing , Dental Restoration Failure , Composite Resins/chemistry , Dental Stress Analysis , Dental Prosthesis Design
9.
BMC Oral Health ; 24(1): 647, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824540

ABSTRACT

BACKGROUND: The survival of ART restorations can be influenced by the choice of the restorative material. The aim of this randomized non-inferiority controlled trial was to compare the 2-year survival rate and cost analysis of two encapsulated glass ionomer cements (GIC) as occlusoproximal restorative materials in primary molars. METHODS: Children from public schools in Tietê (Brazil), aged 4-8 years with occlusoproximal dentine carious lesions in primary molars were selected and randomly assigned to receive either Equia Forte (EF) or Riva Self Cure (RSC) as restorative materials. Treatment was carried out by two trained final-year dental students in schools following ART premises. Restorations were assessed by a trained and calibrated examiner after 2, 6, 12, 18, and 24 months. The primary outcome was restoration survival after 2 years, analyzed using Kaplan-Meier survival and Cox regression analysis (α = 5%). Professional and materials costs for each group were collected in Brazilian Reais (R$) and converted into US dollars (US$) and analyzed using Monte-Carlo simulation. RESULTS: A total of 152 children (76 per group) were included in the study, and 121 (79%) were evaluated after 2 years. The overall 2-year restoration survival rate was 39% (EF = 45%; RSC = 32%) with no difference between the groups. The baseline and 2-year total cost of restorations using RSC was lower when compared to EF (incremental cost: US$ 6.18). CONCLUSION: After two years of follow-up, Riva Self Cure shows comparable restoration survival rates to Equia Forte, being more cost-effective in the Brazilian perspective. TRIAL REGISTRATION: This randomized clinical trial was registered on ClinicalTrials.Gov - NCT02730000.


Subject(s)
Dental Atraumatic Restorative Treatment , Glass Ionomer Cements , Molar , Tooth, Deciduous , Humans , Glass Ionomer Cements/therapeutic use , Glass Ionomer Cements/economics , Child, Preschool , Male , Female , Child , Dental Atraumatic Restorative Treatment/methods , Dental Atraumatic Restorative Treatment/economics , Dental Restoration Failure , Costs and Cost Analysis , Brazil , Dental Caries/therapy , Dental Restoration, Permanent/methods , Dental Restoration, Permanent/economics
10.
Dent Med Probl ; 61(3): 417-426, 2024.
Article in English | MEDLINE | ID: mdl-38888224

ABSTRACT

Severe tooth wear is related to substantial loss of tooth structure, with dentin exposure and significant loss (≥1/3) of the clinical crown. The objective of this systematic review was to summarize and analyze the scientific evidence regarding the mechanical performance of computer-aided design/computer-aided manufacturing (CAD/CAM) composite resin and CAD/CAM lithium disilicate ceramic occlusal veneers, in terms of fatigue and fracture resistance, on severely worn posterior teeth. Currently, occlusal veneers are an alternative for treating worn posterior teeth. Although scientific evidence demonstrates the good performance of lithium disilicate occlusal veneers, there are less brittle materials with a modulus of elasticity more similar to dentin than ceramics, such as resin CAD/CAM blocks. Therefore, it is important to identify which type of material is best for restoring teeth with occlusal wear defects and which material can provide better clinical performance. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive search of the PubMed, Embase, Web of Science, Scopus, Cochrane, OpenGrey, Redalyc, DSpace, and Grey Literature Report databases was conducted and supplemented by a manual search, with no time or language limitations, until January 2022. We aimed to identify studies evaluating the fatigue and fracture resistance of CAD/CAM composite resin and ceramic occlusal veneers. The quality of the full-text articles was evaluated according to the modified Consolidated Standards of Reporting Trials (CONSORT) criteria for in vitro studies, and 400 articles were initially identified. After removing duplicates and applying the selection criteria, 6 studies were included in the review. The results demonstrated that the mechanical performance of CAD/CAM composite resin occlusal veneers is comparable to that of CAD/CAM lithium disilicate occlusal veneers in terms of fatigue and fracture resistance.


Subject(s)
Ceramics , Composite Resins , Computer-Aided Design , Dental Veneers , Humans , Dental Porcelain , Dental Restoration Failure , Tooth Wear/etiology , Tooth Wear/therapy
11.
J Dent Res ; 103(7): 697-704, 2024 07.
Article in English | MEDLINE | ID: mdl-38752325

ABSTRACT

We aimed to evaluate the impact of 2 visual diagnostic strategies for assessing secondary caries and managing permanent posterior restorations on long-term survival. We conducted a diagnostic cluster-randomized clinical trial with 2 parallel groups using different diagnostic strategies: (C+AS) based on caries assessment, marginal adaptation, and marginal staining aspects of the FDI (World Dental Federation) criteria and (C) based on caries assessment using the Caries Associated with Restorations or Sealants (CARS) criteria described by the International Caries Detection and Assessment System (ICDAS). The treatment for the restoration was conducted based on the decision made following the allocated diagnostic strategy. The restorations were then clinically reevaluated for up to 71 mo. The primary outcome was restoration failure (including tooth-level failure: pain, endodontic treatment, and extraction). Cox regression analyses with shared frailty were conducted in the intention-to-treat population, and hazard ratios (HRs) and 95% confidence intervals (95% CIs) were derived. We included 727 restorations from 185 participants and reassessed 502 (69.1%) restorations during follow-up. The evaluations occurred between 6 and 71 mo. At baseline, C led to almost 4 times fewer interventions compared with the C+AS strategy. A total of 371 restorations were assessed in the C group, from which 31 (8.4%) were repaired or replaced. In contrast, the C+AS group had 356 restorations assessed, from which 113 (31.7%) were repaired or replaced. During follow-up, 34 (9.2%) failures were detected in the restorations allocated to the C group and 30 (8.4%) allocated to the C+AS group in the intention-to-treat population, with no significant difference between the groups (HR = 0.83; 95% CI = 0.51 to 1.38; P = 0.435, C+AS as reference). In conclusion, a diagnostic strategy focusing on marginal defects results in more initial interventions but does not improve longevity over the caries-focused strategy, suggesting the need for more conservative approaches.


Subject(s)
Dental Caries , Dental Restoration Failure , Dental Restoration, Permanent , Humans , Dental Restoration, Permanent/methods , Dental Caries/therapy , Dental Caries/diagnosis , Female , Male , Adult , Middle Aged , Dental Marginal Adaptation
12.
J Dent ; 147: 105080, 2024 08.
Article in English | MEDLINE | ID: mdl-38788919

ABSTRACT

OBJECTIVES: To evaluate the influence of dentin moisture on the clinical behavior of a universal adhesive on posterior teeth after 36 months of follow-up. METHODS: Forty-five patients participated in this study. Following a split-mouth design, three operators placed 90 Class I/Class II restorations over moist dentin (MD) or dry (DD) (n = 45) with resin composite (Filtek Bulk Fill) and a universal adhesive used in the etch-and-rinse mode (Single Bond Universal). Each restoration was evaluated according to the FDI and USPHS criteria (postoperative sensitivity, fracture and retention, marginal staining, marginal adaptation, and recurrence of caries) at baseline and after 6-, 12-, and 36 months. For statistical analysis, Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used. RESULTS: No significant difference between groups was observed in each FDI criterion after 36 months of clinical evaluation (p > 0.05). The retention rates (confidence interval 95 %) were 97.37 % (86.5 - 99.5) for both MD and DD without significant difference between them (p > 0.05). Eight restorations (MD = 4; DD = 4) showed minimal marginal staining defects (p > 0.05). Two restorations were lost (MD = 1; DD = 1). Fifteen restorations (MD = 8; DD = 7) presented minor marginal discrepancies according to the FDI criteria (p > 0.05). CONCLUSION: The clinical performance of the universal adhesive when applied in etch-and-rinse mode was not influenced by dentin moisture in posterior bulk-fill composite restorations. CLINICAL SIGNIFICANCE: The level of dentin moisture appears not to influence the clinical efficacy of a universal adhesive when applied using the etch-and-rinse technique in posterior composite resin restorations.


Subject(s)
Bisphenol A-Glycidyl Methacrylate , Composite Resins , Dental Caries , Dental Marginal Adaptation , Dental Restoration Failure , Dental Restoration, Permanent , Dentin Sensitivity , Dentin-Bonding Agents , Dentin , Resin Cements , Humans , Dental Restoration, Permanent/methods , Composite Resins/chemistry , Composite Resins/therapeutic use , Female , Male , Double-Blind Method , Adult , Resin Cements/chemistry , Middle Aged , Bisphenol A-Glycidyl Methacrylate/chemistry , Bisphenol A-Glycidyl Methacrylate/therapeutic use , Dental Caries/therapy , Dentin-Bonding Agents/chemistry , Dentin-Bonding Agents/therapeutic use , Follow-Up Studies , Young Adult , Treatment Outcome , Dental Bonding/methods , Acid Etching, Dental
13.
J Dent ; 147: 105099, 2024 08.
Article in English | MEDLINE | ID: mdl-38797489

ABSTRACT

OBJECTIVE: This randomized controlled clinical trial aimed to evaluate the clinical performance of composite resin restorations placed after selective caries removal to soft dentin (SCRSD) or stepwise excavation (SW) over an 18-month period. METHODS: Inclusion criteria were patients with permanent molars and/or premolars presenting deep caries lesions (≥50 % of the dentin thickness). Teeth were submitted to SCRSD (n = 76) or SW (n = 76). Evaluations were performed based on FDI (World Dental Federation) criterion. Survival analysis was performed to estimate the survival of restorations and its association with clinical variables and socio-demographic characteristics (adjusted Weibull regression model). The study was registered on Registro Brasileiro de Ensaios Clínicos (ReBEC 65ntbc). RESULTS: The follow-up period ranged from 6 to 18 months (mean ± SD 16.3 ± 3.4 months). Patients' ages ranged from 9 to 55 years (mean ± SD 29 ± 10.5 years). A total of 135 teeth (SCRSD = 72; SW = 63) from 101 patients were evaluated. There were 4 failures in the SCRSD group (2 loss of restoration in need of replacement and 2 marginal fractures in need of repair) and 2 in the SW group (fracture in need of repair). The association between explanatory variables and restoration failure showed similar success rates for SW (99.4 %) and SCRSD (97.9 %) (p = 0.16). Patients presenting gingivitis (≥20 % of sites with gingival bleeding) had 8.50 times more risk for failure than those with <20 % of bleeding sites (p = 0.03). CONCLUSION: This study showed that placing a composite resin restoration over soft dentin (after SCRSD) did not affect its clinical performance after 18 months. CLINICAL SIGNIFICANCE: SCRSD is a feasible treatment option for the management of deep caries lesions in permanent teeth as it preserves tooth vitality and tooth structure without compromising restoration longevity.


Subject(s)
Composite Resins , Dental Caries , Dental Cavity Preparation , Dental Restoration Failure , Dental Restoration, Permanent , Dentin , Humans , Dental Caries/therapy , Composite Resins/chemistry , Composite Resins/therapeutic use , Dental Restoration, Permanent/methods , Adult , Male , Female , Middle Aged , Child , Adolescent , Dental Cavity Preparation/methods , Follow-Up Studies , Young Adult , Molar , Dental Materials/chemistry , Treatment Outcome , Bicuspid/surgery
14.
J Esthet Restor Dent ; 36(9): 1281-1300, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38563466

ABSTRACT

OBJECTIVE: This systematic review aimed to analyze the clinical (survival rate, failure risk, or fracture) and laboratory performance (fracture mode or failure) of rehabilitations of endodontically treated teeth, with and without posts. MATERIALS AND METHODS: A systematic search was conducted in the Pubmed, Scopus, Web of Science, Embase, Cochrane Library, and OpenGrey databases up to March 2023, according to PRISMA guidelines. In vitro and clinical studies that compared the clinical and laboratory performance of endodontically treated teeth with and without intraradicular posts were included. Studies selection, data extraction, and risk of bias analysis were performed. RESULTS: Thirty-one in vitro and 7 clinical studies were included. For in vitro studies, fiberglass post (n = 24) was the most mentioned. The follow-up time of the clinical studies ranged from 1 to 17 years, with the fiber-reinforced composite post (n = 3) being the most evaluated, and only failure risk proved to be more favorable for using intraradicular posts. CONCLUSION: Rehabilitations of endodontically treated teeth with and without intraradicular retainers showed no difference in fracture resistance and failure mode, evaluated by in vitro studies. Clinical studies showed no difference in survival rate, but failure risk proved to be more favorable for the use of posts. CLINICAL SIGNIFICANCE: This analysis revealed significant variability between results, however, most laboratory and clinical studies revealed no difference with using the post. Furthermore, it is important to emphasize the need to evaluate the coronary remnant and the general characteristics of the tooth in each situation.


Subject(s)
Tooth, Nonvital , Humans , Post and Core Technique , Dental Restoration Failure , Tooth Fractures
15.
J Esthet Restor Dent ; 36(9): 1326-1336, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38665052

ABSTRACT

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.


Subject(s)
Crowns , Dental Stress Analysis , Zirconium , Zirconium/chemistry , Ceramics/chemistry , Dental Prosthesis Design , Dental Restoration Failure , Dental Prosthesis, Implant-Supported , Materials Testing , Humans
16.
Oral Maxillofac Surg ; 28(3): 1161-1168, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38480619

ABSTRACT

PURPOSE: To evaluate the survival rates of dental implants with a hybrid macrostructure and the surface biomimetically coated with nanohydroxyapatite, placed in horizontally atrophic maxillae previously submitted to the guided bone regeneration (GBR) procedure, associated with the use of a deproteinized bovine bone graft (DBB). METHODS: Twenty-five patients who received 196 implants were involved in this study. First, these patients were submitted to GBR procedures and maxillary sinus lift, where DBB was used as the grafting material. The dental implants were placed after a minimum period of 6 months of the grafting procedures. The patients were followed up every six months and clinical/radiographic examinations were performed to assess the implants, using the following indicators as a reference: (1) Absence of mobility; (2) Absence of pain. Data about the age, surgery time, smoking status, implant size, and time between the grafting procedure and implant placement were correlated with implant failures. RESULTS: Twelve implants failed, generating a survival rate of 94.23%. None of the variables analysed correlated with the implant failures. CONCLUSION: Implants with a hybrid macrostructure and surface biomimetically coated with nanohydroxyapatite present good survival rates in horizontally atrophic maxillae grafted with DBB.


Subject(s)
Dental Implants , Maxilla , Humans , Middle Aged , Male , Female , Maxilla/surgery , Aged , Animals , Dental Restoration Failure , Adult , Bone Transplantation/methods , Durapatite , Cattle , Sinus Floor Augmentation/methods , Bone Substitutes , Alveolar Bone Loss/surgery , Alveolar Bone Loss/diagnostic imaging , Heterografts/transplantation , Dental Implantation, Endosseous/methods , Survival Analysis
17.
Clin Implant Dent Relat Res ; 26(3): 469-481, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38450931

ABSTRACT

OBJECTIVE: To evaluate the long-term survival and success rates of implants placed in reconstructed areas using microvascularized or non-microvascularized extraoral bone grafts. MATERIALS AND METHODS: An electronic search was performed in five databases and in gray literature for articles published until June, 2023. The eligibility criteria comprised observational studies (prospective or retrospective) and clinical trials, reporting survival and success rates of implants placed in extraoral bone grafts. A meta-analysis (implant failure) was categorized into subgroups based on the type of bone graft used. The risk of bias within studies was assessed using the Newcastle-Ottawa Scale. RESULTS: Thirty-one studies met the inclusion criteria. The mean follow-up time was 92 months. The summary estimate of survival rate at the implant level were 94.9% (CI: 90.1%-97.4%) for non-vascularized iliac graft, 96.5% (CI: 91.4%-98.6%) for non-vascularized calvaria graft, and 92.3% (CI: 89.1%-94.6%) for vascularized fibula graft. The mean success rate and marginal bone loss (MBL) were 83.2%; 2.25 mm, 92.2%; 0.93 mm, and 87.6%; 1.49 mm, respectively. CONCLUSIONS: Implants placed in areas reconstructed using extraoral autogenous bone graft have high long-term survival rates and low long-term MBLs. The data did not demonstrate clinically relevant differences in the survival, success, or MBL of grafts from different donor areas or with different vascularization. This systematic review was registered in INPLASY under number INPLASY202390004.


Subject(s)
Bone Transplantation , Dental Implantation, Endosseous , Dental Implants , Humans , Bone Transplantation/methods , Dental Implantation, Endosseous/methods , Dental Restoration Failure , Alveolar Ridge Augmentation/methods
18.
J Dent ; 144: 104930, 2024 05.
Article in English | MEDLINE | ID: mdl-38471581

ABSTRACT

OBJECTIVES: This 24-month, double-blind, split-mouth randomized clinical trial aimed to compare the retention rates of a preheated thermoviscous composite resin (PHT) compared to a non-heated composite resin (NHT) in non-carious cervical lesions (NCCLs). METHODS: A total of 120 restorations were restored on NCCLs using a preheated (VisCalor bulk, Voco GmbH) and a non-heated (Admira Fusion, Voco GmbH) composite resins with 60 restorations per group. A universal adhesive in the selective enamel conditioning was applied. In the PHT group, composite was heated at 68 °C for using a bench heater. In the NHT group, no heating was employed. Both restorative materials were dispensed into caps and inserted into the NCCLs. The restorations were evaluated at baseline, 6, 12, 18, and after 24 months of clinical service using the FDI criteria. Statistical analysis was performed with Kaplan-Meier estimation analysis for retention/fracture rate and Chi-square test for the other FDI parameters (α=0.05). RESULTS: After 24 months 108 restorations were assessed. Seven restorations were lost (two for PHT group and five for NHT group), and the retention rates (95 % confidence interval [CI]) were 96.7 % (81.5-99.9) for PHT group and 90.8 % (81.1-96.0) for NHT group, with no statistical differences between them (p > 0.05). The hazard ratio (95 % CI) was 0.52 (0.27 to 1.01), with no significant difference within groups. In terms of all other FDI parameters that were assessed, all restorations were deemed clinically acceptable. CONCLUSIONS: Both composites showed high rates of retention rates after 24 months. CLINICAL SIGNIFICANCE: The clinical performance of the new preheated thermoviscous was found to be as good as the non-heated composite after 24-month of clinical evaluation in non-carious cervical lesions. REGISTRATION OF CLINICAL TRIALS: RBR-6d6gxxz.


Subject(s)
Composite Resins , Dental Restoration, Permanent , Hot Temperature , Tooth Cervix , Humans , Composite Resins/chemistry , Composite Resins/therapeutic use , Dental Restoration, Permanent/methods , Female , Double-Blind Method , Male , Tooth Cervix/pathology , Adult , Middle Aged , Dental Materials/chemistry , Dental Restoration Failure , Young Adult , Dentin Sensitivity , Resin Cements/chemistry , Follow-Up Studies , Kaplan-Meier Estimate , Treatment Outcome , Surface Properties , Tooth Erosion/therapy
19.
J Oral Implantol ; 50(3): 127-135, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38530824

ABSTRACT

This study evaluated the clinical survival rates of 170 Morse taper implants through clinical and mechanical parameters in different therapeutic approaches such as single crowns, fixed partial prostheses, and fixed full-arch prostheses. Patients referred to the Center on Education and Research on Dental Implants from May 2017 to July 2018 with the indication for dental implant therapy, aged >18 years, without periodontal disease, recent evidence of inflammatory activity or other oral disorders, current pregnancy, uncontrolled diabetes mellitus or heavy smoking habit were included in this study. After 12 weeks of healing since the implants were placed in the mandible and after 16 weeks following implants placed in the maxilla, patients returned to the Center for prosthetic rehabilitation. After implant therapy, all patients underwent periodical, clinical, and prosthetic examinations every 6 months. Prosthetic restorations involved 109 fixed reconstructions in function. Few prosthetic complications were reported (6.55%). Twenty implants were rehabilitated with cemented prostheses; from those, 1 crown suffered a loss in retention/decementation. Of the 148 implants rehabilitated with screwed-retained prostheses, 6.76% suffered prosthetic screw loosening. The cumulative implant survival rate was 98.2%. When peri-implant tissue health was evaluated, the keratinized mucosa band appeared related to peri-implant tissue stability. Thus, Morse taper implants represented a successful procedure for implant rehabilitation, with a high cumulative implant survival rate, low prevalence of biological and prosthetic complications, and good stability of peri-implant tissues over the assessed period.


Subject(s)
Dental Implants , Humans , Follow-Up Studies , Female , Middle Aged , Male , Adult , Dental Prosthesis, Implant-Supported , Dental Prosthesis Design , Dental Restoration Failure , Aged , Dental Implantation, Endosseous , Crowns
20.
J Dent ; 142: 104837, 2024 03.
Article in English | MEDLINE | ID: mdl-38211688

ABSTRACT

OBJECTIVES: This study aimed to compare the success and survival rates of metal-ceramic crowns and composite resin restorations applied in root filled teeth that received a glass fiber post. METHODS: A prospective, randomized controlled trial, with equivalent parallel groups was designed. Eighty-two teeth were randomly allocated to the metal-ceramic or composite resin groups. Multivariate Cox regression analysis with shared frailty for patients and Kaplan-Meier curves were performed using success and survival rates (p<0.05). RESULTS: Seventy-five post-retained restorations (34 metal-ceramic crowns and 41 composite restorations) in 62 patients were analyzed. The median follow-up was 8.1 years [IQR 4.0-9.9]. Twenty-seven failures were observed. Twenty-two failures (81.5 %) were observed in the composite resin group, of which six (27.3 %) were not repairable. Five failures (18.5 %) were observed in the metal-ceramic crown group, of which three (66.6 %) were non-repairable. The cumulative success rate at 8 years was 85.0 % for crowns (AFR=1.31 %) and 43.2 % for composite resins (AFR=6.58 %), while the survival rate was 93.8 % for crowns (AFR=0.52 %) and 97.6 % for composite resins (AFR=0.20 %). Considering the success rates, adjusted multivariate Cox regression showed that composite resin had a Hazard Ratio of 5.07 (95 %CI, 1.99-12.89) greater than the metal-ceramic crown. No significant difference in the failure risk was observed when the survival rates were considered (HR=0.38, 95 %CI (0.10 - 1.44), p = 0.156). Co-variables did not affect the success and survival rates (p>0.05). CONCLUSIONS: Metal-ceramic crowns showed a higher success rate than composite restorations. The survival rates were similar, but composite restorations presented a higher need for repairs. CLINICAL SIGNIFICANCE: Post-retained composite restorations may need more reinterventions during the lifecycle, although more preservation of sound tooth structure is expected with a large restoration of resin post-and-core. These aspects have to be discussed with the patient for decision-making planning.


Subject(s)
Post and Core Technique , Tooth, Nonvital , Humans , Prospective Studies , Tooth, Nonvital/therapy , Crowns , Dental Porcelain/chemistry , Composite Resins/chemistry , Glass , Metals , Dental Restoration Failure
SELECTION OF CITATIONS
SEARCH DETAIL