Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.035
Filter
1.
Kyobu Geka ; 77(6): 438-441, 2024 Jun.
Article in Japanese | MEDLINE | ID: mdl-39009537

ABSTRACT

An 80-year-old man had a guidewire in his aorta since catheter laboratory accident 4 years ago. He recently started to suffer mental distress and underwent coronary angiography that revealed an entrapped guidewire and significant stenoses in each of three major coronary arteries. The guidewire could not be removed using transcatheter technique. Thus, after careful consideration, we decided to perform entrapped guidewire removal through minimally invasive surgical approach instead of median sternotomy. Post-operative course was uneventful. Although surgical approach should be tailored in each case, minimally invasive approach can be a choice for entrapped guidewire removal.


Subject(s)
Minimally Invasive Surgical Procedures , Humans , Male , Aged, 80 and over , Minimally Invasive Surgical Procedures/methods , Device Removal/methods , Aorta/surgery
3.
Medicine (Baltimore) ; 103(28): e38872, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38996134

ABSTRACT

RATIONALE: The intrauterine device is one of the effective, safe, convenient, economical, and reversible contraceptive methods. Although its contraceptive effect is definite, some female patients may experience complications such as expulsion, bleeding, and pregnancy with the device in place. Rectal perforation is one of the rare and serious complications, which can lead to complications such as abdominal infection and intestinal adhesions, severely affecting the quality of life of patients. PATIENT CONCERNS: A 34-year-old female was sent to the Department of Gastroenterology with noticeable left lower quadrant abdominal pain. She had presented with abdominal discomfort and anal tenesmus 1 year earlier. Two months ago, her abdominal pain had gradually worsened and she was presented to our hospital. DIAGNOSES: Investigations, including colonoscopy and computed tomography scan, had revealed an intrauterine device migrated and perforated into the rectum. INTERVENTIONS AND OUTCOMES: The patient underwent successful colonoscopic removal of the intrauterine device. She recovered well after the treatment. LESSONS: This case proves that endoscopic therapy can be considered the preferred method for removing intrauterine devices displaced into the digestive tract lumen.


Subject(s)
Colonoscopy , Intestinal Perforation , Intrauterine Device Migration , Rectum , Humans , Female , Adult , Colonoscopy/adverse effects , Colonoscopy/methods , Intestinal Perforation/surgery , Intestinal Perforation/etiology , Rectum/injuries , Intrauterine Device Migration/adverse effects , Device Removal/methods , Intrauterine Devices/adverse effects
4.
Article in English | MEDLINE | ID: mdl-38967795

ABSTRACT

This case report illustrates how to implant a central paracorporeal temporary biventricular assist device in a 17-year-old patient with acute heart failure due to a fulminant form of coronavirus disease 2019 myocarditis. The procedure was carried out after prior veno-arterial extracorporeal membrane oxygenation support. Myocardial biopsies and biventricular assist device explants are also included in the report. The patient was weaned on postoperative day 6 and discharged without any significant complications. One year after the event, the patient remains asymptomatic with normal biventricular function and a normal lifestyle.


Subject(s)
COVID-19 , Heart Failure , Heart-Assist Devices , Myocarditis , Humans , Myocarditis/surgery , COVID-19/complications , Adolescent , Heart Failure/surgery , Male , SARS-CoV-2 , Extracorporeal Membrane Oxygenation/methods , Device Removal/methods
5.
Kobe J Med Sci ; 70(3): E77-E80, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39053969

ABSTRACT

BACKGROUND: We present a case involving a pregnant woman who needed transurethral lithotripsy for ureteral stent removal because of the stent encrustation. CLINICAL CASE: A 34-year-old woman was diagnosed with calculous pyelonephritis, and a double-loop ureteral stent was placed in her right ureter, after which the pyelonephritis resolved. One week after her delivery, we attempted to remove the ureteral stent; however, the encrustation of the proximal and distal coils made it impossible. We then crushed the encrustation by transurethral lithotripsy and removed the ureteral stent successfully. The encrustation component was calcium phosphate, and the urinary pH during pregnancy and after delivery was 7.5. CONCLUSION: Even in pregnant patients, patients placed ureteral stents for obstructive pyelonephritis with high urine pH might need to be replaced in the short term due to concerns regarding phosphate encrustation.


Subject(s)
Device Removal , Stents , Humans , Female , Adult , Stents/adverse effects , Pregnancy , Device Removal/methods , Pyelonephritis/etiology , Ureter/surgery , Lithotripsy , Pregnancy Complications
6.
Eur J Med Res ; 29(1): 384, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39054532

ABSTRACT

STUDY DESIGN: Retrospective case series. OBJECTIVES: We aimed to describe with a novel surgical approach for the removal of posterior thoracolumbar implant in patients with symptomatic failure of the implant and present our preliminary results with this method. METHODS: This retrospective, single-center study was performed in the neurosurgery department of a university hospital. Data were gathered from the medical files of 314 patients (243 women, 77.39%; 71 men, 22.61%) with symptomatic thoracolumbar implant failure that underwent implant removal operation using our novel technique between 2010 and 2020. Symptoms, radiological findings, intraoperative findings as well as clinical outcomes were evaluated. RESULTS: In our series, the average age was 46.5 years (range: 21-84) with a mean follow-up duration of 7 years (range: 3 months to 10 years). Preoperatively, the most common symptoms were leg pain and numbness of the lower extremity. Postoperatively, no major complications were noted. Clinical progression of symptoms was avoided by surgery in all patients, while we came across removal difficulties due to screw-screwdriver mismatch in 15 of 314 surgeries (4.78%). Our novel approach allowed successful screw removal including these challenging cases. CONCLUSIONS: We suggest that our novel approach is a practical and effective for the removal of posterior thoracolumbar implant in cases with symptomatic failure attributed to screw-screwdriver mismatch. Further trials are warranted to assess the efficacy of this technique to overcome surgical problems associated with screw removal.


Subject(s)
Device Removal , Lumbar Vertebrae , Thoracic Vertebrae , Humans , Male , Female , Adult , Middle Aged , Lumbar Vertebrae/surgery , Aged , Follow-Up Studies , Retrospective Studies , Thoracic Vertebrae/surgery , Device Removal/methods , Device Removal/adverse effects , Aged, 80 and over , Young Adult , Bone Screws , Spinal Fusion/methods , Spinal Fusion/adverse effects
10.
Orthop Surg ; 16(8): 2087-2092, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38946660

ABSTRACT

BACKGROUND: Mobile bearing fracture is a rare long-term complication of unicompartmental knee arthroplasty (UKA), and relevant reports are sparse. Hence, its treatment options need further exploration. CASE PRESENTATION: This study presents the case of fracture of a polyethylene insert that occurred 12 years after mobile bearing medial UKA in a 75-year-old overweight woman who then underwent surgical intervention at our institution. However, we encountered significant challenges in removing the fragments from the broken bearing, resulting in retention of the remaining one-third of the fragment. We solved this problem by replacing the fractured insert with thicker mobile bearing. During the 1-month postoperative follow-up, the patient achieved good range of motion and excellent satisfaction, with no reported complications and a Knee Society Score of 90. Additionally, we reviewed the literature on the treatment for mobile bearing fractures after UKA. CONCLUSIONS: Bearing fracture is a rare cause of failure of mobile bearing UKA. This case highlights the challenges of UKA fracture bearing retrieval and underscores that mobile bearing replacement can be an effective intervention. The case we report shows that when removal of a residual meniscal bearing in a posterior dislocation is difficult to achieve, compromise may be an appropriate option because it does not cause additional complaints to the patient. This case emphasizes the importance of the surgeon having a thorough preoperative understanding of the location and potential pitfalls of fracture fragments in such situations.


Subject(s)
Arthroplasty, Replacement, Knee , Device Removal , Knee Prosthesis , Prosthesis Failure , Humans , Female , Arthroplasty, Replacement, Knee/methods , Aged , Device Removal/methods , Reoperation/methods , Prosthesis Design
13.
Ann Plast Surg ; 92(6S Suppl 4): S419-S422, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38857007

ABSTRACT

BACKGROUND: Tissue expander-based breast reconstruction is associated with high rates of infectious complications, often leading to tissue expander explants and delays in receipt of definitive breast reconstruction and adjuvant therapy. In this study, we describe a single-stage technique where deep inferior epigastric artery perforator (DIEP) flaps are used to salvage actively infected tissue expanders among patients originally planning for free flap reconstruction. METHODS: In this technique, patients with tissue expander infections without systemic illness are maintained on oral antibiotics until the day of their DIEP flap surgery, at which time tissue expander explant is performed in conjunction with aggressive attempt at total capsulectomy and immediate DIEP flap reconstruction. Patients are maintained on 1-2 weeks of oral antibiotics tailored to culture data. Patients undergoing this immediate salvage protocol were retrospectively reviewed, and complications and length of stay were assessed. RESULTS: In a retrospective series, a total of six consecutive patients with culture-proven tissue expander infections underwent tissue expander removal and DIEP flap reconstruction in a single stage and were maintained on 7-14 days of oral antibiotics postoperatively. Within this cohort, no surgical site infections, microvascular complications, partial flap losses, reoperations, or returns to the operating room were noted within a 90-day period. CONCLUSIONS: Among a select cohort of patients, actively infected tissue expanders may be salvaged with free flap breast reconstruction in a single surgery with a low incidence of postoperative complications. Prospective studies are needed to evaluate the influence of this treatment strategy on costs, number of surgeries, and dissatisfaction after staged breast reconstruction complicated by tissue expander infections.


Subject(s)
Epigastric Arteries , Mammaplasty , Perforator Flap , Salvage Therapy , Tissue Expansion Devices , Humans , Perforator Flap/blood supply , Female , Retrospective Studies , Mammaplasty/methods , Middle Aged , Epigastric Arteries/transplantation , Epigastric Arteries/surgery , Salvage Therapy/methods , Adult , Prosthesis-Related Infections/surgery , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/administration & dosage , Tissue Expansion/methods , Breast Neoplasms/surgery , Treatment Outcome , Device Removal/methods
14.
Int J Cardiol ; 411: 132264, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38878871

ABSTRACT

BACKGROUND: Complete removal of cardiac implantable electronic devices (CIEDs) is recommended in patients with CIED infections, including both systemic and localized pocket infection. The aim of the study was to provide an up-to-date and comprehensive assessment of evidence relating to the effect of complete CIED extraction in patients with a CIED infection. METHODS: We performed a systematic review and meta-analysis of studies reporting short- and mid-term outcomes in patients who had a device infection or infective endocarditis (IE) and underwent complete removal of the cardiac device (generator and leads) compared to those who received conservative therapy (no removal, partial removal, local antibiotic infiltration or isolated antibiotic therapy). The primary outcome was reinfection/relapse. Secondary outcomes were short-term (30-day/in-hospital) and mid-term (mean follow-up: 43.0 months) mortality. Random effects model was performed. RESULTS: Thirty-two studies met the criteria for inclusion in the final analysis. Patients with complete CIED extraction (n = 905) exhibited a lower rate of relapse/re-infection compared to patients (n = 195) with a conservative treatment approach (n = 195, OR 0.02, 95%CI 0.01-0.06, p < 0.0001, mean-follow-up: 16.1 months). Additionally, these patients displayed a lower short- (OR 0.40, 95%CI 0.23-0.69, p = 0.01) and mid-term (OR 0.52, 95%CI 0.34-0.78, p = 0.002) mortality. CONCLUSIONS: The analysis indicates that patients with a CIED infection who undergo complete CIED extraction exhibit a lower rate of relapse/re-infection. Additionally, a lower short- and mid-term mortality is observed, although it is acknowledged that this outcome may be influenced by treatment allocation bias.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/therapy , Defibrillators, Implantable/adverse effects , Device Removal/methods , Pacemaker, Artificial/adverse effects , Treatment Outcome , Conservative Treatment/methods , Anti-Bacterial Agents/therapeutic use
15.
J Cardiothorac Surg ; 19(1): 306, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822410

ABSTRACT

Peripheral venous catheter fracture with cardiovascular embolization is a rare but potentially serious complication. Herein, we report a case of peripheral venous catheter fracture with embolization in right ventricle in a preterm infant. The catheter fragment was successfully removed by surgical procedure via median sternotomy under cardiopulmonary bypass(CPB).We hope this case will increase awareness of this rare complication and improve cannulation safety.


Subject(s)
Catheterization, Peripheral , Device Removal , Infant, Premature , Humans , Infant, Newborn , Catheterization, Peripheral/methods , Device Removal/methods , Equipment Failure , Heart Ventricles/surgery
16.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38833618

ABSTRACT

AIMS: Debulking of infective mass to reduce the burden if infective material is a fundamental principle in the surgical management of infection. The aim of this study was to investigate the validity of this principle in patients undergoing transvenous lead extraction in the context of bloodstream infection (BSI). METHODS AND RESULTS: We performed an observational single-centre study on patients that underwent transvenous lead extraction due to a BSI, with or without lead-associated vegetations, in combination with a percutaneous aspiration system during the study period 2015-22. One hundred thirty-seven patients were included in the final analysis. In patients with an active BSI at the time of intervention, the use of a percutaneous aspiration system had a significant impact on survival (log-rank: P = 0.0082), while for patients with a suppressed BSI at the time of intervention, the use of a percutaneous aspiration system had no significant impact on survival (log-rank: P = 0.25). CONCLUSION: A reduction of the infective burden by percutaneous debulking of lead vegetations might improve survival in patients with an active BSI.


Subject(s)
Device Removal , Prosthesis-Related Infections , Humans , Female , Male , Device Removal/methods , Aged , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/mortality , Middle Aged , Treatment Outcome , Defibrillators, Implantable/adverse effects , Suction , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/mortality , Endocarditis, Bacterial/etiology , Retrospective Studies , Time Factors , Risk Factors , Aged, 80 and over
18.
J Cardiovasc Electrophysiol ; 35(8): 1701-1705, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38845191

ABSTRACT

INTRODUCTION: Transvenous lead extractions (TLEs) for cardiac implantable electronic device complications often encounter difficulties with strong adhesions to the myocardium or vessels. In this report, we introduce a novel "Four-Stage Rocket" technique for effective TLE in cases where conventional methods fail. METHODS AND RESULTS: Two challenging cases where conventional TLE methods failed were treated using a combination of four devices: Needle's Eye Snare, Agilis NxT Steerable Introducer, GlideLight Laser sheath, and GORE® DrySeal Flex Introducer sheath, employed via the inferior vena cava. The "Four-Stage Rocket" technique successfully detached firmly adhered leads near the tricuspid valve annulus, where the traditional superior vena cava approach was inadequate. CONCLUSION: The "Four-Stage Rocket" technique offers a potential alternative in complex TLE cases, aligning the laser direction with the adhesion detachment and reducing the tissue damage risk.


Subject(s)
Defibrillators, Implantable , Device Removal , Femoral Vein , Lasers , Pacemaker, Artificial , Humans , Device Removal/instrumentation , Device Removal/methods , Male , Aged , Treatment Outcome , Female , Middle Aged , Catheterization, Peripheral/instrumentation
20.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL