Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 35.079
1.
Med Sci Monit ; 30: e943321, 2024 Jun 12.
Article En | MEDLINE | ID: mdl-38863180

BACKGROUND This study explored the integration of conductive threads into a microfluidic compact disc (CD), developed using the xurographic method, for a potential sweat biosensing platform. MATERIAL AND METHODS The microfluidic CD platform, fabricated using the xurographic method with PVC films, included venting channels and conductive threads linked to copper electrodes. With distinct microfluidic sets for load and metering, flow control, and measurement, the CD's operation involved spinning for sequential liquid movement. Impedance analysis using HIOKI IM3590 was conducted for saline and artificial sweat solutions on 4 identical CDs, ensuring reliable conductivity and measurements over a 1 kHz to 200 kHz frequency range. RESULTS Significant differences in |Z| values were observed between saline and artificial sweat treatments. 27.5 µL of saline differed significantly from 27.5 µL of artificial sweat, 72.5 µL of saline from 72.5 µL of artificial sweat, and 192.5 µL of saline from 192.5 µL of sweat. Significant disparities in |Z| values were observed between dry fibers and Groups 2, 3, and 4 (varying saline amounts). No significant differences emerged between dry fibers and Groups 6, 7, and 8 (distinct artificial sweat amounts). These findings underscore variations in fiber characteristics between equivalent exposures, emphasizing the nuanced response of the microfluidic CD platform to different liquid compositions. CONCLUSIONS This study shows the potential of integrating conductive threads in a microfluidic CD platform for sweat sensing. Challenges in volume control and thread coating degradation must be addressed for transformative biosensing devices in personalized healthcare.


Biosensing Techniques , Lab-On-A-Chip Devices , Sweat , Sweat/chemistry , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Humans , Microfluidics/methods , Microfluidics/instrumentation , Electric Conductivity , Electrodes , Electric Impedance
2.
Biomed Eng Online ; 23(1): 51, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38835079

BACKGROUND: Functional electrical stimulation (FES) is a rehabilitation technique that enables functional improvements in patients with motor control impairments. This study presents an original design and prototyping method for a smart sleeve for FES applications. The article explains how to integrate a carbon-based dry electrode into a textile structure and ensure an electrical connection between the electrodes and the stimulator for effective delivery of the FES. It also describes the materials and the step-by-step manufacturing processes. RESULTS: The carbon-based dry electrode is integrated into the textile substrate by a thermal compression molding process on an embroidered conductive matrix. This matrix is composed of textile silver-plated conductive yarns and is linked to the stimulator. Besides ensuring the electrical connection, the matrix improves the fixation between the textile substrate and the electrode. The stimulation intensity, the perceived comfort and the muscle torque generated by the smart FES sleeve were compared to hydrogel electrodes. The results show a better average comfort and a higher average stimulation intensity with the smart FES sleeve, while there were no significant differences for the muscle torque generated. CONCLUSIONS: The integration of the proposed dry electrodes into a textile is a viable solution. The wearable FES system does not negatively impact the electrodes' performance, and tends to improve it. Additionally, the proposed prototyping method is applicable to an entire garment in order to target all muscles. Moreover, the process is feasible for industrial production and commercialization since all materials and processes used are already available on the market.


Electrodes , Textiles , Humans , Electric Stimulation/instrumentation , Equipment Design , Male , Adult , Electric Conductivity , Carbon/chemistry , Torque
3.
Water Sci Technol ; 89(10): 2646-2660, 2024 May.
Article En | MEDLINE | ID: mdl-38822605

The objective of this study was to assess, through simulation, conductivity variations in pulp and paper circuits when recycling waste water treatment plant (WWTP) effluent with a view to reducing fresh water use in a tissue mill. WWTP effluent was recycled in the process for different uses. A PS2000 digital model coupled with the PHREEQC chemical simulation engine was used to identify and quantify the main sources of conductivity: caustic soda, sodium bisulphite and acetate production through anaerobic microbial activity. Recycling WWTP effluent enables fresh water uptake to be reduced by 50% when used for pulp dilution or white water, by 81% when used in paper machine showers, and up to 96% for all uses combined. As fresh water use decreases, circuit closure increases along with, consequently, COD and conductivity. COD build-up can be controlled by best available techniques application. Recycling WWTP effluent has a strong impact on conductivity. However, the impact of high conductivity levels on additives performance is limited in the case of the mill studied. Acetate concentration could be controlled by better agitation of tanks or the introduction of air by pumps. Furthermore, limiting acetate production can reduce the need for caustic soda to control the pH.


Industrial Waste , Paper , Recycling , Waste Disposal, Fluid , Waste Disposal, Fluid/methods , Recycling/methods , Electric Conductivity , Models, Theoretical , Wastewater/chemistry
4.
Phys Med Biol ; 69(12)2024 Jun 13.
Article En | MEDLINE | ID: mdl-38830364

ObjectiveFull-form Magnetic Resonance Electrical Properties Tomography (MREPT) requires bothB1+magnitude and phase information. SinceB1+phase can be obtained faster and with higher SNR compared toB1+magnitude, several phase-based methods have been developed for conductivity imaging. However, phase-based methods suffer from a concave bias due to the assumption that∇|B1+|is negligible in the ROI.ApproachIn this paper, we re-derive the central equation of phase-based cr-MREPT without assuming that∇|B1+|is negligible and thus propose a correction method directly integrated into the equation system.Main resultsProposed method successfully corrects the concave bias on both simulated and experimental data and significantly increases image quality.SignificanceThe proposed correction method depends on a very low-resolution|B1+|map, and therefore the imaging time does not increase significantly for obtainingB1+magnitude. Moreover, correction can be achieved using simulatedB1+magnitude, hence completely removing the additional imaging requirement.


Image Processing, Computer-Assisted , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Tomography/methods , Electric Conductivity , Phantoms, Imaging
5.
PLoS One ; 19(6): e0302135, 2024.
Article En | MEDLINE | ID: mdl-38861530

Soilless agriculture is acknowledged worldwide because it uses organic leftovers as a means of supporting intensive and efficient plant production. However, the quality of potting media deteriorates because of lower nutrient content and excessive shrinkage of most organic materials. A current study was undertaken to identify the optimal blend of locally available organic materials with desirable qualities for use as potting media. Therefore, different ingredients, viz., Pinus roxburghii needles, sugarcane bagasse, and farmyard manure were used alone or in combination as potting media to test their suitability by growing spinach as a test crop. Results showed that an increase in Pinus roxburghii needles and sugarcane bagasse decreased medium pH and electrical conductivity. Higher pH and electrical conductivity were recorded for the treatments having a higher farmyard manure ratio (≥50%) in combination. Except for pine needles 100%, pH and electrical conductivity were in the recommended range. The growth attributes include, leaves plant-1, shoot length, fresh- and dry shoot weight along with plant macronutrients (nitrogen, phosphorous, and potassium) and micronutrients (iron, copper, manganese, and zinc) content were higher in treatment pine needles 50%+farmyard manure 50% followed by pine needles 25%+farmyard manure 50%+sugarcane bagasse 25%. Moreover, the particular treatment of pine needles 50%+farmyard manure 50% exhibited the highest concentrations of macro- (nitrogen, phosphorus, and potassium) as well as micronutrients (iron, copper, manganese, and zinc) in the potting media following the harvest. This study highlights the potential of utilizing agro-industrial litter/waste as a soilless growing medium for spinach production under greenhouse conditions. When employed in appropriate proportions, this approach not only addresses disposal concerns but also proves effective for sustainable cultivation. Further research is needed to investigate the use of these wastes as potting media by mixing various particle-size ingredients.


Manure , Pinus , Saccharum , Manure/analysis , Saccharum/growth & development , Saccharum/chemistry , Pinus/growth & development , Cellulose , Vegetables/growth & development , Vegetables/chemistry , Spinacia oleracea/growth & development , Spinacia oleracea/metabolism , Hydrogen-Ion Concentration , Electric Conductivity , Agriculture/methods , Plant Leaves/growth & development , Plant Leaves/chemistry , Soil/chemistry , Nitrogen/analysis
6.
Sensors (Basel) ; 24(11)2024 May 21.
Article En | MEDLINE | ID: mdl-38894053

The advancement of flexible electrodes triggered research on wearables and health monitoring applications. Metal-based bioelectrodes encounter low mechanical strength and skin discomfort at the electrode-skin interface. Thus, recent research has focused on the development of flexible surface electrodes with low electrochemical resistance and high conductivity. This study investigated the development of a novel, flexible, surface electrode based on a MXene/polydimethylsiloxane (PDMS)/glycerol composite. MXenes offer the benefit of featuring highly conductive transition metals with metallic properties, including a group of carbides, nitrides, and carbonitrides, while PDMS exhibits inherent biostability, flexibility, and biocompatibility. Among the various MXene-based electrode compositions prepared in this work, those composed of 15% and 20% MXene content were further evaluated for their potential in electrophysiological sensing applications. The samples underwent a range of characterization techniques, including electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), as well as mechanical and bio-signal sensing from the skin. The experimental findings indicated that the compositions demonstrated favorable bulk impedances of 280 and 111 Ω, along with conductivities of 0.462 and 1.533 mS/cm, respectively. Additionally, they displayed promising electrochemical stability, featuring charge storage densities of 0.665 mC/cm2 and 1.99 mC/cm2, respectively. By conducting mechanical tests, Young's moduli were determined to be 2.61 MPa and 2.18 MPa, respectively. The composite samples exhibited elongation of 139% and 144%, respectively. Thus, MXene-based bioelectrodes show promising potential for flexible and wearable electronics and bio-signal sensing applications.


Electrodes , Wearable Electronic Devices , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Humans , Dimethylpolysiloxanes/chemistry , Dielectric Spectroscopy , Electric Conductivity , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Electric Impedance , Glycerol/chemistry , Electrophysiological Phenomena , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods
7.
Sensors (Basel) ; 24(11)2024 May 23.
Article En | MEDLINE | ID: mdl-38894120

Accurately capturing human movements is a crucial element of health status monitoring and a necessary precondition for realizing future virtual reality/augmented reality applications. Flexible motion sensors with exceptional sensitivity are capable of detecting physical activities by converting them into resistance fluctuations. Silver nanowires (AgNWs) have become a preferred choice for the development of various types of sensors due to their outstanding electrical conductivity, transparency, and flexibility within polymer composites. Herein, we present the design and fabrication of a flexible strain sensor based on silver nanowires. Suitable substrate materials were selected, and the sensor's sensitivity and fatigue properties were characterized and tested, with the sensor maintaining reliability after 5000 deformation cycles. Different sensors were prepared by controlling the concentration of silver nanowires to achieve the collection of motion signals from various parts of the human body. Additionally, we explored potential applications of these sensors in fields such as health monitoring and virtual reality. In summary, this work integrated the acquisition of different human motion signals, demonstrating great potential for future multifunctional wearable electronic devices.


Nanowires , Silver , Wearable Electronic Devices , Nanowires/chemistry , Humans , Silver/chemistry , Movement/physiology , Electric Conductivity , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods
8.
Sensors (Basel) ; 24(11)2024 May 24.
Article En | MEDLINE | ID: mdl-38894182

Wearable sensors are rapidly gaining influence in the diagnostics, monitoring, and treatment of disease, thereby improving patient outcomes. In this review, we aim to explore how these advances can be applied to magnetic resonance imaging (MRI). We begin by (i) introducing limitations in current flexible/stretchable RF coils and then move to the broader field of flexible sensor technology to identify translatable technologies. To this goal, we discuss (ii) emerging materials currently used for sensor substrates, (iii) stretchable conductive materials, (iv) pairing and matching of conductors with substrates, and (v) implementation of lumped elements such as capacitors. Applicable (vi) fabrication methods are presented, and the review concludes with a brief commentary on (vii) the implementation of the discussed sensor technologies in MRI coil applications. The main takeaway of our research is that a large body of work has led to exciting new sensor innovations allowing for stretchable wearables, but further exploration of materials and manufacturing techniques remains necessary, especially when applied to MRI diagnostics.


Magnetic Resonance Imaging , Radio Waves , Wearable Electronic Devices , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Humans , Equipment Design , Electric Conductivity
9.
Int J Biol Macromol ; 271(Pt 1): 132699, 2024 Jun.
Article En | MEDLINE | ID: mdl-38824103

Conductive hydrogels, as novel flexible biosensors, have demonstrated significant potential in areas such as soft robotics, electronic devices, and wearable technology. Graphene is a promising conductive material, but its dispersibility in aqueous solutions exists difficulties. Here, we discover that untreated graphene, after exfoliation by different ionic liquids, can disperse well in aqueous solutions. We investigate the impact of four ionic liquids with varying alkyl chain lengths ([Bmim]Cl, [Omim]Cl, [Dmim]Cl, [Hmim]Cl) on the dispersibility of grapheme, and a dual physically cross-linked network hydrogel structure is designed using acrylamide (AM), acrylic acid (AA), methyl methacrylate octadecyl ester (SMA), ionic liquid@graphene (ILs@GN), and chitosan (CS). Notably, SMA, CS, AA and AM act as dynamic cross-linking points through hydrophobic interactions and hydrogen bonding, playing a crucial role in energy dissipation. The resulting hydrogel exhibits outstanding stretchability (2250 %), remarkable toughness (1.53 MJ/m3) in tensile deformation performance, high compressive strength (1.13 MPa), rapid electrical responsiveness (response time âˆ¼ 50 ms), high electrical conductivity (12.11 mS/cm), and excellent strain sensing capability (GF = 12.31, strain = 1000 %). These advantages make our composite hydrogel demonstrate high stability in extensive deformations, offering repeatability in pressure and strain and making it a promising candidate for multifunctional sensors and flexible electrodes.


Chitosan , Electric Conductivity , Graphite , Hydrogels , Ionic Liquids , Chitosan/chemistry , Hydrogels/chemistry , Ionic Liquids/chemistry , Graphite/chemistry , Hydrophobic and Hydrophilic Interactions
10.
ACS Appl Mater Interfaces ; 16(25): 32702-32712, 2024 Jun 26.
Article En | MEDLINE | ID: mdl-38870327

Herein, we report a dual-functional flexible sensor (DFFS) using a magnetic conductive polymer composed of nickel (Ni), carbon black (CB), and polydimethylsiloxane (PDMS). The material selection for the DFFS utilizes the excellent elasticity of the PDMS matrix and the synergistic interaction between Ni and CB. The DFFS has a wide strain range of 0-170%, a high sensitivity of 74.13 (140-170%), and a low detection limit of 0.3% strain. The DFFS based on superior performance can accurately detect microstrain/microvibration, oncoming/contacting objects, and bicycle riding speed. Additionally, the DFFS can be used for comprehensive monitoring of human movements. Therefore, the DFFS of this work shows significant value for implementation in intelligent wearable devices and noncontact intelligent control.


Dimethylpolysiloxanes , Microspheres , Nickel , Soot , Wearable Electronic Devices , Dimethylpolysiloxanes/chemistry , Humans , Nickel/chemistry , Soot/chemistry , Movement , Electric Conductivity
11.
Lab Chip ; 24(13): 3294-3304, 2024 Jun 25.
Article En | MEDLINE | ID: mdl-38864519

On-demand drug delivery holds great promise to optimize pharmaceutical efficacy while minimizing the side effects. However, existing on-demand drug delivery systems often require complicated manufacturing processes that preclude their wide implementation of a broad range of drugs. In this work, we demonstrate the introduction of MXene-coated microneedles (MNs) into bioelectronics for digitally controllable gate-valve drug delivery. MXenes, featuring high electronic conductivity, excellent biocompatibility, and solution processibility, enable low-cost scalability for printable bioelectronics. In an electrolytic state (e.g., body fluid), the coated MXene is oxidized and desorbed due to redox reactions caused by electrical bias, allowing the underlying drug to be controllably released. The MXene-incorporated drug delivery system not only demonstrates excellent biocompatibility and operational stability, but also features low-cost construction and sustainable usage. Besides, these MXene-coated MNs allow both on-demand transformation and local-region customization, further increasing the structural versatility and capability of multidrug delivery systems.


Drug Delivery Systems , Electric Conductivity , Drug Delivery Systems/instrumentation , Water/chemistry , Humans , Equipment Design
12.
Sci Robot ; 9(91): eadk3925, 2024 Jun 12.
Article En | MEDLINE | ID: mdl-38865475

Electrotactile stimulus is a form of sensory substitution in which an electrical signal is perceived as a mechanical sensation. The electrotactile effect could, in principle, recapitulate a range of tactile experience by selective activation of nerve endings. However, the method has been plagued by inconsistency, galvanic reactions, pain and desensitization, and unwanted stimulation of nontactile nerves. Here, we describe how a soft conductive block copolymer, a stretchable layout, and concentric electrodes, along with psychophysical thresholding, can circumvent these shortcomings. These purpose-designed materials, device layouts, and calibration techniques make it possible to generate accurate and reproducible sensations across a cohort of 10 human participants and to do so at ultralow currents (≥6 microamperes) without pain or desensitization. This material, form factor, and psychophysical approach could be useful for haptic devices and as a tool for activation of the peripheral nervous system.


Elastomers , Electric Conductivity , Psychophysics , Touch , Humans , Touch/physiology , Adult , Female , Male , Equipment Design , Electric Stimulation , Young Adult , Polymers , Electrodes , Calibration , Touch Perception/physiology
13.
Anim Sci J ; 95(1): e13959, 2024.
Article En | MEDLINE | ID: mdl-38769761

This study investigates the relationships between subclinical mastitis and milk quality with selected microRNAs in cow milk. California Mastitis Test (CMT)-positive (n = 20) and negative (n = 20) samples were compared (Experiment I). Additionally, samples with CMT-positive but microbiological-negative, as well as positive for only Staphylococcus subspecies (Staph spp.) and only Streptococcus subspecies (Strep spp.) were examined (Experiment II). Four groups were formed in Experiment II: Group I (CMT and microbiological-negative) (n = 20), Group II (CMT-positive but microbiological-negative) (n = 10), Group III (Staph spp.) (n = 5), Group IV (Strep spp.) (n = 5). While electrical conductivity, somatic cell count (SCC), malondialdehyde (MDA) increased, miR-27a-3p and miR-223 upregulated and miR-125b downregulated in the CMT-positive group in Experiment I. SCC and MDA were higher in CMT-positive groups. miR-27a-3p and miR-223 upregulated in Groups III and IV. While miR-155 is upregulated, miR-125b downregulated in Group IV. Milk fat is positively correlated with miR-148a and miR-223. As miR-27a-3p positively correlated with SCC and MDA, miR-125b negatively correlated with electrical conductivity and SCC. miR-148a and MDA were positively correlated. miR-155 was correlated with fat-free dry matter, protein, lactose, and freezing point. miR-223 was positively correlated with SCC and miR-148a. Results particularly highlight miR-27a-3p and miR-223 as potential biomarkers in subclinical mastitis, especially those caused by Staph spp. and Strep spp., while miR-148a, miR-155, and miR-223 stand out in determining milk quality.


Mastitis, Bovine , MicroRNAs , Milk , Animals , Milk/microbiology , MicroRNAs/metabolism , MicroRNAs/genetics , Cattle , Female , Mastitis, Bovine/microbiology , Mastitis, Bovine/diagnosis , Mastitis, Bovine/genetics , Mastitis, Bovine/metabolism , Staphylococcus/isolation & purification , Cell Count/veterinary , Streptococcus/isolation & purification , Food Quality , Malondialdehyde/metabolism , Malondialdehyde/analysis , Electric Conductivity , Asymptomatic Infections
14.
ACS Appl Mater Interfaces ; 16(21): 27952-27960, 2024 May 29.
Article En | MEDLINE | ID: mdl-38808703

Capable of directly capturing various physiological signals from human skin, skin-interfaced bioelectronics has emerged as a promising option for human health monitoring. However, the accuracy and reliability of the measured signals can be greatly affected by body movements or skin deformations (e.g., stretching, wrinkling, and compression). This study presents an ultraconformal, motion artifact-free, and multifunctional skin bioelectronic sensing platform fabricated by a simple and user-friendly laser patterning approach for sensing high-quality human physiological data. The highly conductive membrane based on the room-temperature coalesced Ag/Cu@Cu core-shell nanoparticles in a mixed solution of polymers can partially dissolve and locally deform in the presence of water to form conformal contact with the skin. The resulting sensors to capture improved electrophysiological signals upon various skin deformations and other biophysical signals provide an effective means to monitor health conditions and create human-machine interfaces. The highly conductive and stretchable membrane can also be used as interconnects to connect commercial off-the-shelf chips to allow extended functionalities, and the proof-of-concept demonstration is highlighted in an integrated pulse oximeter. The easy-to-remove feature of the resulting device with water further allows the device to be applied on delicate skin, such as the infant and elderly.


Wearable Electronic Devices , Humans , Skin/chemistry , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Silver/chemistry , Copper/chemistry , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Artifacts , Metal Nanoparticles/chemistry , Motion , Electric Conductivity
15.
Int J Nanomedicine ; 19: 4495-4513, 2024.
Article En | MEDLINE | ID: mdl-38799696

Background: Electrical stimulation (ES) can effectively promote skin wound healing; however, single-electrode-based ES strategies are difficult to cover the entire wound area, and the effectiveness of ES is often limited by the inconsistent mechanical properties of the electrode and wound tissue. The above factors may lead to ES treatment is not ideal. Methods: A multifunctional conductive hydrogel dressing containing methacrylated gelatin (GelMA), Ti3C2 and collagen binding antimicrobial peptides (V-Os) was developed to improve wound management. Ti3C2 was selected as the electrode component due to its excellent electrical conductivity, the modified antimicrobial peptide V-Os could replace traditional antibiotics to suppress bacterial infections, and GelMA hydrogel was used due to its clinical applicability in wound healing. Results: The results showed that this new hydrogel dressing (GelMA@Ti3C2/V-Os) not only has excellent electrical conductivity and biocompatibility but also has a durable and efficient bactericidal effect. The modified antimicrobial peptides V-Os used were able to bind more closely to GelMA hydrogel to exert long-lasting antibacterial effects. The results of cell experiment showed that the GelMA@Ti3C2/V-Os hydrogel dressing could enhance the effect of current stimulation and significantly improve the migration, proliferation and tissue repair related genes expression of fibroblasts. In vitro experiments results showed that under ES, GelMA@Ti3C2/V-Os hydrogel dressing could promote re-epithelialization, enhance angiogenesis, mediate immune response and prevent wound infection. Conclusion: This multifunctional nanocomposite hydrogel could provide new strategies for promoting infectious wound healing.


Anti-Bacterial Agents , Electric Conductivity , Hydrogels , Nanocomposites , Wound Healing , Wound Healing/drug effects , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Nanocomposites/chemistry , Animals , Hydrogels/chemistry , Hydrogels/pharmacology , Mice , Electric Stimulation , Gelatin/chemistry , Humans , Antimicrobial Cationic Peptides/chemistry , Antimicrobial Cationic Peptides/pharmacology , Fibroblasts/drug effects , Titanium/chemistry , Titanium/pharmacology , Male , Cell Proliferation/drug effects , Electric Stimulation Therapy/methods
16.
Int J Mol Sci ; 25(10)2024 May 17.
Article En | MEDLINE | ID: mdl-38791524

Actin filaments, as key components of the cytoskeleton, have aroused great interest due to their numerous functional roles in eukaryotic cells, including intracellular electrical signaling. The aim of this research is to characterize the alternating current (AC) conduction characteristics of both globular and polymerized actin and quantitatively compare their values to those theoretically predicted earlier. Actin filaments have been demonstrated to act as conducting bionanowires, forming a signaling network capable of transmitting ionic waves in cells. We performed conductivity measurements for different concentrations of actin, considering both unpolymerized and polymerized actin to identify potential differences in their electrical properties. These measurements revealed two relevant characteristics: first, the polymerized actin, arranged in filaments, has a lower impedance than its globular counterpart; second, an increase in the actin concentration leads to higher conductivities. Furthermore, from the data collected, we developed a quantitative model to represent the electrical properties of actin in a buffer solution. We hypothesize that actin filaments can be modeled as electrical resistor-inductor-capacitor (RLC) circuits, where the resistive contribution is due to the viscous ion flows along the filaments; the inductive contribution is due to the solenoidal flows along and around the helix-shaped filament and the capacitive contribution is due to the counterion layer formed around each negatively charged filament.


Actin Cytoskeleton , Actins , Electric Conductivity , Actin Cytoskeleton/metabolism , Actin Cytoskeleton/chemistry , Actins/metabolism , Actins/chemistry , Animals , Polymerization
17.
Int J Mol Sci ; 25(10)2024 May 20.
Article En | MEDLINE | ID: mdl-38791590

This paper describes the process of producing chemiresistors based on hybrid nanostructures obtained from graphene and conducting polymers. The technology of graphene presumed the following: dispersion and support stabilization based on the chemical vapor deposition technique; transfer of the graphene to the substrate by spin-coating of polymethyl methacrylate; and thermal treatment and electrochemical delamination. For the process at T = 950 °C, a better settlement of the grains was noticed, with the formation of layers predominantly characterized by peaks and not by depressions. The technology for obtaining hybrid nanostructures from graphene and conducting polymers was drop-casting, with solutions of Poly(3-hexylthiophene (P3HT) and Poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-bithiophene] (F8T2). In the case of F8T2, compared to P3HT, a 10 times larger dimension of grain size and about 7 times larger distances between the peak clusters were noticed. To generate chemiresistors from graphene-polymer structures, an ink-jet printer was used, and the metallization was made with commercial copper ink for printed electronics, leading to a structure of a resistor with an active surface of about 1 cm2. Experimental calibration curves were plotted for both sensing structures, for a domain of CH4 of up to 1000 ppm concentration in air. A linearity of the curve for the low concentration of CH4 was noticed for the graphene structure with F8T2, presenting a sensitivity of about 6 times higher compared with the graphene structure with P3HT, which makes the sensing structure of graphene with F8T2 more feasible and reliable for the medical application of irritable bowel syndrome evaluation.


Graphite , Irritable Bowel Syndrome , Methane , Nanostructures , Polymers , Graphite/chemistry , Nanostructures/chemistry , Polymers/chemistry , Methane/chemistry , Irritable Bowel Syndrome/metabolism , Humans , Breath Tests/methods , Thiophenes/chemistry , Electric Conductivity
18.
J Exp Biol ; 227(10)2024 May 15.
Article En | MEDLINE | ID: mdl-38712896

Weakly electric gymnotiform fishes use self-generated electric organ discharges (EODs) to navigate and communicate. The electrosensory range for these processes is a function of EOD amplitude, determined by the fish's electric organ (EO) output and the electrical conductivity of the surrounding water. Anthropogenic activity, such as deforestation, dams and industrial/agricultural runoff, are known to increase water conductivity in neotropical habitats, likely reducing the electrosensory range of these fish. We investigated whether fish modulate EO output as means of re-expanding electrosensory range after a rapid increase in water conductivity in the pulse-type Brachyhypopomus gauderio and the wave-type Eigenmannia virescens. Furthermore, because EOD production incurs significant metabolic costs, we assessed whether such compensation is associated with an increase in metabolic rate. Following the conductivity increase, B. gauderio increased EOD amplitude by 20.2±4.3% over 6 days but with no associated increase in metabolic rate, whereas the EOD amplitude of E. virescens remained constant, accompanied by an unexpected decrease in metabolic rate. Our results suggest that B. gauderio uses a compensation mechanism that requires no metabolic investment, such as impedance matching, or a physiological trade-off wherein energy is diverted from other physiological processes to increase EO output. These divergent responses between species could be the result of differences in reproductive life history or evolutionary adaptations to different aquatic habitats. Continued investigation of electrosensory responses to changing water conditions will be essential for understanding the effects of anthropogenic disturbances on gymnotiforms, and potential physiological mechanisms for adapting to a rapidly changing aquatic environment.


Electric Conductivity , Electric Organ , Gymnotiformes , Animals , Electric Organ/physiology , Gymnotiformes/physiology , Electric Fish/physiology , Water/metabolism
19.
Int J Biol Macromol ; 269(Pt 1): 132032, 2024 Jun.
Article En | MEDLINE | ID: mdl-38702004

Advancements in two-dimensional materials, particularly MXenes, have spurred the development of innovative composites through their integration with natural polymers such as sodium alginate (SA). Mxenes exhibit a broad specific surface area, excellent electrical conductivity, and an abundance of surface terminations, which can be combined with SA to maximize the synergistic effect of the materials. This article provides a comprehensive review of state-of-the-art techniques in the fabrication of SA/MXene composites, analyzing the resulting structural and functional enhancements with a specific focus on advancing the design of these composites for practical applications. A detailed exploration of SA/MXene composites is provided, highlighting their utility in various sectors, such as wearable electronics, wastewater treatment, biomedical applications, and electromagnetic interference (EMI) shielding. The review identifies the unique advantages conferred by incorporating MXene in these composites, examines the current challenges, and proposes future research directions to understand and optimize these promising materials thoroughly. The remarkable properties of MXenes are emphasized as crucial for advancing the performance of SA-based composites, indicating significant potential for developing high-performance composite materials.


Alginates , Alginates/chemistry , Nanocomposites/chemistry , Electric Conductivity , Wearable Electronic Devices
20.
J Mater Chem B ; 12(21): 5238-5247, 2024 May 29.
Article En | MEDLINE | ID: mdl-38699788

This study introduces a thermally responsive smart hydrogel with enhanced electrical properties achieved through volume switching. This advancement was realized by incorporating multiscale liquid metal particles (LMPs) into the PNIPAM hydrogel during polymerization, using their inherent elasticity and conductivity when deswelled. Unlike traditional conductive additives, LMPs endow the PNIPAM hydrogel with a remarkably consistent volume switching ratio, significantly enhancing electrical switching. This is attributed to the minimal nucleation effect of LMPs during polymerization and their liquid-like behavior, like vacancies in the polymeric hydrogel under compression. The PNIPAM/LMP hydrogel exhibits the highest electrical switching, with an unprecedented switch of 6.1 orders of magnitude. Even after repeated swelling/deswelling cycles that merge some LMPs and increase the conductivity when swelled, the hydrogel consistently maintains an electrical switch exceeding 4.5 orders of magnitude, which is still the highest record to date. Comprehensive measurements reveal that the hydrogel possesses robust mechanical properties, a tissue-like compression modulus, biocompatibility, and self-healing capabilities. These features make the PNIPAM/LMP hydrogel an ideal candidate for long-term implantable bioelectronics, offering a solution to the mechanical mismatch with dynamic human tissues.


Acrylic Resins , Electric Conductivity , Hydrogels , Hydrogels/chemistry , Acrylic Resins/chemistry , Temperature , Biocompatible Materials/chemistry , Metals/chemistry , Particle Size , Animals
...