Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 24.088
1.
Water Sci Technol ; 89(10): 2783-2795, 2024 May.
Article En | MEDLINE | ID: mdl-38822614

Photocatalytically active ceramic flat sheet membranes based on a nanostructured titanium dioxide (TiO2) coating were produced for photocatalytic water treatment. The nano-TiO2 layer was produced by a novel combination of magnetron sputtering of a thin titanium layer on silicon carbide (SiC) membranes, followed by electrochemical oxidation (anodization) and subsequent heat treatment (HT). Characterization by Raman spectra and field emission scanning electron microscopy proved the presence of a nanostructured anatase layer on the membranes. The influence of the titanium layer thickness on the TiO2 formation process and the photocatalytic properties were investigated using anodization curves, by using cyclovoltammetry measurements, and by quantifying the generated hydroxyl radicals (OH•) under UV-A irradiation in water. Promising photocatalytic activity and permeability of the nano-TiO2-coated membranes could be demonstrated. A titanium layer of at least 2 µm was necessary for significant photocatalytic effects. The membrane sample with a 10 µm Ti/TiO2 layer had the highest photocatalytic activity showing a formation rate of 1.26 × 10-6 mmol OH• s-1. Furthermore, the membranes were tested several times, and a decrease in radical formation was observed. Assuming that these can be attributed to adsorption processes of the reactants, initial experiments were carried out to reactivate the photocatalyzer.


Carbon Compounds, Inorganic , Hydroxyl Radical , Membranes, Artificial , Silicon Compounds , Titanium , Water Purification , Titanium/chemistry , Hydroxyl Radical/chemistry , Water Purification/methods , Catalysis , Silicon Compounds/chemistry , Carbon Compounds, Inorganic/chemistry , Electrochemical Techniques , Nanostructures/chemistry , Photochemical Processes
2.
Anal Chim Acta ; 1312: 342686, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834256

BACKGROUND: Fentanyl and its derivatives are a type of potent opioid analgesics, with the characteristics of diverse structure, high toxicity, extremely low content, and high fatality rate. Currently, they have become one of the most serious problems in international drug abuse control due to their extensive use in drug production and use. Therefore, the development of a rapid, sensitive, and accurate method for detecting trace fentanyl is of great significance. In this study, in view of its complex structure and trace concentration, a new molecular imprinting electrochemical sensor was developed through molecular simulations followed by experimental validation to detect trace fentanyl. RESULTS: The process consisted of first obtaining the optimal functional monomer and its molar ratio through molecular simulations. The recognition sites of fentanyl-imprinted polymers were predicted to guide the synthesis of imprinted membranes with precision approach to ensure an efficient and accurate reaction process. Reduced graphene oxide (ErGO) was then deposited on glassy carbon electrode surface by electrochemical reduction to yield large numbers of active sites suitable for catalyzing reactions of fentanyl piperidine for promoted efficient electron transfer and amplified sensitivity of the sensor. Accordingly, fentanyl molecularly imprinted film was formed through one-step electropolymerization to yield greatly improved sensing selectivity due to the specific recognition of molecularly imprinted polymer. Under optimal experimental conditions, the fentanyl sensor showed an extended detection range of 3.84 × 10-9 mol L-1-1.72 × 10-6 mol L-1 and a detection limit of 1.28 × 10-9 mol L-1. SIGNIFICANCE: A distinctive feature of this sensor is its molecularly imprinted polymerized membrane, which offers excellent specific recognition, thereby boosting the sensor's selectivity. Throughout the sensor's development process, molecular simulations were employed to steer the synthesis of molecularly imprinted polymers and predict the recognition sites of fentanyl-imprinted polymers. The experimental outcomes proved to align with the simulation data. The final sensor exhibited outstanding selectivity, repeatability, stability, and high sensitivity. The sensor was effectively used to reliably track fentanyl in human serum samples, with acceptable analytical reliability, suggesting its potential for practical applications.


Electrochemical Techniques , Fentanyl , Molecular Imprinting , Fentanyl/analysis , Fentanyl/blood , Fentanyl/chemistry , Molecularly Imprinted Polymers/chemistry , Electrodes , Limit of Detection , Graphite/chemistry , Molecular Dynamics Simulation , Analgesics, Opioid/blood , Analgesics, Opioid/analysis , Analgesics, Opioid/chemistry , Humans
3.
Anal Chim Acta ; 1312: 342746, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834274

BACKGROUND: The widespread use and abuse of antibiotics has resulted in the pollution of water sources with antibiotic residues, posing a threat to human health, the environment, and the economy. Therefore, a highly sensitive and selective method is required for their detection in water samples. Herein, advanced ultrasensitive electrochemical sensor platform was developed by integrating gold-silver alloy nanocoral clusters (Au-Ag-ANCCs) with functionalized multi-walled carbon nanotube-carbon paste electrode (f-MWCNT-CPE) and choline chloride (ChCl) nanocomposites for simultaneously determining the residues of antimicrobial drugs, rifampicin (RAMP) and norfloxacin (NFX), in water samples. RESULTS: The developed sensor (Au-Ag-ANCCs/f-MWCNTs-CPE/ChCl) was extensively characterized using several analytical (UV-Vis, FT-IR, XRD, SEM, and EDX) and electrochemical (EIS, CV, and SWV) techniques. It exhibited outstanding performance in a wide linear range, from 14 pM to 115 µM for RAMP, and from 0.9 nM to 200 µM for NFX, with a limit of detection (LOD, 3σ/m, S/N = 3, n = 5) and a limit of quantification (LOQ, 10σ/m, S/N = 3, n = 5) values of 2.7 pM and 8.85 pM for RAMP, and 0.14 nM and 0.47 nM for NFX, respectively. The sensor also exhibited exceptional reproducibility, stability, and resistance to interference. SIGNIFICANCE: The developed sensor was effectively utilized to determine RAMP and NFX residues in hospital wastewater, river, and tap water samples, yielding recoveries within the range of 96.8-103 % and relative standard deviations below 5 %. Generally, the proposed sensor demonstrated remarkable performance in detecting the target analytes, making it an ideal tool and the first of its kind for addressing global antibiotic residue pollutants in water sources.


Electrochemical Techniques , Norfloxacin , Rifampin , Water Pollutants, Chemical , Norfloxacin/analysis , Water Pollutants, Chemical/analysis , Rifampin/analysis , Electrodes , Limit of Detection , Anti-Bacterial Agents/analysis , Nanotubes, Carbon/chemistry
4.
Anal Chim Acta ; 1312: 342761, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834276

BACKGROUND: Diabetes is a significant health threat, with its prevalence and burden increasing worldwide indicating its challenge for global healthcare management. To decrease the disease severity, the diabetic patients are recommended to regularly check their blood glucose levels. The conventional finger-pricking test possesses some drawbacks, including painfulness and infection risk. Nowadays, smartphone has become a part of our lives offering an important benefit in self-health monitoring. Thus, non-invasive wearable sweat glucose sensor connected with a smartphone readout is of interest for real-time glucose detection. RESULTS: Wearable sweat glucose sensing device is fabricated for self-monitoring of diabetes. This device is designed as a body strap consisting of a sensing strip and a portable potentiostat connected with a smartphone readout via Bluetooth. The sensing strip is modified by carbon nanotubes (CNTs)-cellulose nanofibers (CNFs), followed by electrodeposition of Prussian blue. To preserve the activity of glucose oxidase (GOx) immobilized on the modified sensing strip, chitosan is coated on the top layer of the electrode strip. Herein, machine learning is implemented to correlate between the electrochemical results and the nanomaterial content along with deposition cycle of prussian blue, which provide the highest current response signal. The optimized regression models provide an insight, establishing a robust framework for design of high-performance glucose sensor. SIGNIFICANCE: This wearable glucose sensing device connected with a smartphone readout offers a user-friendly platform for real-time sweat glucose monitoring. This device provides a linear range of 0.1-1.5 mM with a detection limit of 0.1 mM that is sufficient enough for distinguishing between normal and diabetes patient with a cut-off level of 0.3 mM. This platform might be an alternative tool for improving health management for diabetes patients.


Biosensing Techniques , Diabetes Mellitus , Machine Learning , Smartphone , Sweat , Wearable Electronic Devices , Humans , Sweat/chemistry , Biosensing Techniques/instrumentation , Diabetes Mellitus/diagnosis , Glucose/analysis , Nanotubes, Carbon/chemistry , Glucose Oxidase/chemistry , Glucose Oxidase/metabolism , Electrochemical Techniques/instrumentation
5.
Anal Chim Acta ; 1312: 342762, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834277

Mucin1 (MUC1) is an extensively glycosylated transmembrane protein that is widely distributed and overexpressed on the surface of cancer cells, playing an important role in tumor occurrence and metastasis. Therefore, highly sensitive detection of MUC1 is of great significance for early diagnosis, treatment monitoring, and prognosis of cancer. Here, an ultra-sensitive photoelectrochemical (PEC) sensing platform was developed based on an aptamer amplification strategy for highly selective and sensitive detection of MUC1 overexpressed in serum and on cancer cell surfaces. The sensing platform utilized copper phthalocyanine to fabricate porous organic polymers (CuPc POPs), and was effectively integrated with g-C3N4/MXene to form a ternary heterojunction material (g-C3N4/MXene/CuPc POPs). This material effectively improved electron transfer capability, significantly enhanced light utilization, and greatly enhanced photoelectric conversion efficiency, resulting in a dramatic increase in photocurrent response. MUC1 aptamer 1 was immobilized on a chitosan-modified photoelectrode for the selective capture of MUC1 or MCF-7 cancer cells. When the target substance was present, MUC1 aptamer 2 labeled with methylene blue (MB) was specifically adsorbed on the electrode surface, leading to enhanced photocurrent. The concentration of MUC1 directly correlated with the number of MB molecules attracted to the electrode surface, establishing a linear relationship between photocurrent intensity and MUC1 concentration. The PEC biosensor exhibited excellent sensitivity for MUC1 detection with a wide detection range from 1 × 10-7 to 10 ng/mL and a detection limit of 8.1 ag/mL. The detection range for MCF-7 cells was from 2 × 101 to 2 × 106 cells/mL, with the capability for detecting single MCF-7 cells. The aptamer amplification strategy significantly enhanced PEC performance, and open up a promising platform to establish high selectivity, stability, and ultrasensitive analytical techniques.


Aptamers, Nucleotide , Electrochemical Techniques , Mucin-1 , Polymers , Mucin-1/analysis , Humans , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , MCF-7 Cells , Porosity , Polymers/chemistry , Limit of Detection , Biosensing Techniques/methods , Indoles/chemistry , Photochemical Processes , Organometallic Compounds/chemistry
6.
Anal Chim Acta ; 1312: 342763, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834278

Developing effective electrochemiluminescence (ECL) platforms is always an essential concern in highly sensitive bioanalysis. In this work, a low-triggering-potential ECL sensor was designed for detecting synthetic cathinone 3,4-methylenedioxypyrovalerone (MDPV) based on a dual-signal amplification strategy. Initially, a probe was created by integrating Ruthenium into the hollow porphyrin-based MOF (PCN-222) structure to decrease the excitation potential and enhance ECL performance without external co-reaction accelerators. Additionally, for the first time, photonic crystals (PCs) assembled from covalent organic frameworks (COFs) were employed to amplify the ECL signal, thereby increasing the photon flux and the loading capacity of the ECL emitter to enhance sensitivity of the sensor. In the presence of the target MDPV, the aptamer labeled with Ferrocene (Fc) experienced conformational changes, causing Fc to approach the luminophore and resulting in ECL quenching. This effect was attributed to aptamer's conformational changes induced by the target, directly correlating with the target concentration. The constructed sensor showed good linearity with the target MDPV concentration, covering a dynamic range from 1.0 × 10-14 to 1.0 × 10-6 g/L and achieved an ultra-low detection limit of 4.79 × 10-15 g/L. This work employed dual amplification strategies to enhance ECL signals effectively, providing a novel method for developing highly responsive and bioactive sensors.


Electrochemical Techniques , Luminescent Measurements , Metal-Organic Frameworks , Photons , Pyrrolidines , Ruthenium , Metal-Organic Frameworks/chemistry , Electrochemical Techniques/methods , Ruthenium/chemistry , Pyrrolidines/chemistry , Alkaloids/chemistry , Alkaloids/analysis , Limit of Detection
7.
Anal Chim Acta ; 1312: 342765, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834279

The sensitive, accurate and rapid detection of carbohydrate antigen 125 (CA125) is essential for the early diagnosis and clinical management of ovarian cancer, but there is still challenge. Herein, a photoelectrochemical (PEC) immunosensor based on CdS/Bi2S3/NiS ternary sulfide heterostructured photocatalyst was presented for the detection of CA125. The CdS/Bi2S3/NiS was synthesized by a one-step hydrothermal approach. The heterojunction comprising of CdS and Bi2S3 could separate photogenerated carriers, the introduced narrow bandgap NiS could act as electron-conducting bridge to facilitate the transfer of interfacial photogenerated electrons, thereby improving the photoelectric conversion efficiency. Due to their synergistic effect, the photocurrent response produced by the composite was up to 14.6 times of pure CdS. On the basis, a PEC immunosensor was constructed by introducing the CA125 antibody through thioglycolic acid linkage. It was found that the resulting immunosensor showed good performance. Under the optimized conditions, its linear detection range was as wide as 1 pg mL-1-50 ng mL-1, and the detection limit was low to 0.85 pg mL-1. Furthermore, we experimentally tested its anti-interference, stability and reproducibility, and satisfactory results were achieved. The practicable feasibility of the sensor was confirmed by testing serum sample. Thus this work provided a simple, fast and enough sensitive approach for CA125 monitoring.


Bismuth , CA-125 Antigen , Cadmium Compounds , Electrochemical Techniques , Sulfides , Cadmium Compounds/chemistry , Sulfides/chemistry , Humans , Electrochemical Techniques/methods , CA-125 Antigen/blood , CA-125 Antigen/analysis , Bismuth/chemistry , Limit of Detection , Immunoassay/methods , Biosensing Techniques/methods
8.
Mikrochim Acta ; 191(7): 370, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38837084

The development of an ultrasensitive and precise measurement of a breast cancer biomarker (cancer antigen 15-3; CA15-3) in complex human serum is essential for the early diagnosis of cancer in groups of healthy populations and the treatment of patients. However, currently available testing technologies suffer from insufficient sensitivity toward CA15-3, which severely limits early large-scale screening of breast cancer patients. We report a versatile electrochemical immunoassay method based on atomically cobalt-dispersed nitrogen-doped carbon (Co-NC)-modified disposable screen-printed carbon electrode (SPCE) with alkaline phosphatase (ALP) and its metabolite, ascorbic acid 2-phosphate (AAP), as the electrochemical labeling and redox signaling unit for sensitive detection of low-abundance CA15-3. During electrochemical detection by differential pulse voltammetry (DPV), it was found that the Co-NC-SPCE electrode did not have a current signal response to the AAP substrate; however, it had an extremely favorable response current to ascorbic acid (AA). Based on the above principle, the target CA15-3-triggered immunoassay enriched ALP-catalyzed AAP produces a large amount of AA, resulting in a significant change in the system current signal, thereby realizing the highly sensitive detection of CA15-3. Under the optimal AAP substrate concentration and ALP catalysis time, the Co-NC-SPCE-based electrochemical immunoassay demonstrated a good DPV current for CA15-3 in the assay interval of 1.0 mU/mL to 10,000 mU/mL, with a calculated limit of detection of 0.38 mU/mL. Since Co-NC-SPCE has an excellent DPV current response to AA and employs split-type scheme, the constructed electrochemical immunoassay has the merits of high preciseness and anti-interference, and its clinical diagnostic results are comparable to those of commercial kits.


Ascorbic Acid , Biomarkers, Tumor , Breast Neoplasms , Carbon , Cobalt , Electrochemical Techniques , Mucin-1 , Nitrogen , Humans , Immunoassay/methods , Breast Neoplasms/blood , Mucin-1/blood , Biomarkers, Tumor/blood , Electrochemical Techniques/methods , Carbon/chemistry , Nitrogen/chemistry , Cobalt/chemistry , Ascorbic Acid/chemistry , Ascorbic Acid/blood , Ascorbic Acid/analogs & derivatives , Female , Limit of Detection , Alkaline Phosphatase/blood , Alkaline Phosphatase/chemistry , Electrodes , Biosensing Techniques/methods
9.
Mikrochim Acta ; 191(7): 364, 2024 06 03.
Article En | MEDLINE | ID: mdl-38831034

CdIn2S4 and zinc tetrakis(4-carboxyphenyl)porphyrin (ZnTCPP) were synthesized by hydrothermal method, and an organic dye-sensitized inorganic semiconductor ZnTCPP/CdIn2S4 type II heterojunction was constructed on a fluorine-doped tin oxide (FTO) substrate electrode. A sandwich immunostructure for signal-attenuation photoelectrochemical (PEC) detection of cardiac troponin I (cTnI) was constructed using the ZnTCPP/CdIn2S4/FTO photoanode and a horseradish peroxidase (HRP)-ZnFe2O4-Ab2-bovine serum albumin (BSA) immunolabeling complex. The bioenzyme HRP and the HRP-like nanozyme ZnFe2O4 can co-catalyze the oxidation of 4-chloro-1-naphthol (4-CN) by H2O2 to produce an insoluble precipitate on the photoanode, thus notably reducing the anodic photocurrent for quantitative determination of cTnI. Under the optimal conditions, the photocurrent at 0 V vs. SCE in 0.1 M phosphate buffer solution (pH 7.40) containing 0.1 M ascorbic acid was linear with the logarithm of cTnI concentration from 500 fg mL-1 to 50.0 ng mL-1, and the limit of detection (LOD, S/N = 3) is 0.15 pg mL-1. Spiked recoveries were 95.1% ~ 104% for assay of cTnI in human serum samples.


Electrochemical Techniques , Limit of Detection , Tin Compounds , Troponin I , Troponin I/blood , Humans , Electrochemical Techniques/methods , Immunoassay/methods , Tin Compounds/chemistry , Catalysis , Horseradish Peroxidase/chemistry , Naphthols/chemistry , Metalloporphyrins/chemistry , Electrodes , Hydrogen Peroxide/chemistry , Serum Albumin, Bovine/chemistry , Photochemical Processes , Animals , Biosensing Techniques/methods , Semiconductors , Cattle , Sulfides/chemistry , Porphyrins/chemistry
10.
Mikrochim Acta ; 191(6): 362, 2024 06 01.
Article En | MEDLINE | ID: mdl-38822867

Rapid and accurate in situ determination of dopamine is of great significance in the study of neurological diseases. In this work, poly (3,4-ethylenedioxythiophene): poly (styrenesulfonic acid) (PEDOT: PSS)/graphene oxide (GO) fibers were fabricated by an effective method based on microfluidic wet spinning technology. The composite microfibers with stratified and dense arrangement were continuously prepared by injecting PEDOT: PSS and GO dispersion solutions into a microfluidic chip. PEDOT: PSS/GO fiber microelectrodes with high electrochemical activity and enhanced electrochemical oxidation activity of dopamine were constructed by controlling the structure composition of the microfibers with varying flow rate. The fabricated fiber microelectrode had a low detection limit (4.56 nM) and wide detection range (0.01-8.0 µM) for dopamine detection with excellent stability, repeatability, and reproducibility. In addition, the PEDOT: PSS/GO fiber microelectrode prepared was successfully used for the detection of dopamine in human serum and PC12 cells. The strategy for the fabrication of multi-component fiber microelectrodes is a new and effective approach for monitoring the intercellular neurotransmitter dopamine and has high potential as an implantable neural microelectrode.


Dopamine , Graphite , Microelectrodes , Polystyrenes , PC12 Cells , Dopamine/blood , Humans , Rats , Animals , Polystyrenes/chemistry , Graphite/chemistry , Limit of Detection , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Thiophenes/chemistry , Lab-On-A-Chip Devices , Polymers
11.
Mikrochim Acta ; 191(6): 361, 2024 06 01.
Article En | MEDLINE | ID: mdl-38822891

A one-shot CO2 laser-based strategy to generate conductive reduced graphene oxide (rGO) decorated with nanoceria (nCe) is proposed. The 2D/0D rGO-nCe films, integrated as catalytic sensing layers in paper-based sensors, were employed for on-site monitoring of indoor fogging treatments against Listeria monocytogenes (Lm), a ubiquitous pathogenic bacterium. The rGO-nCe laser-assisted synthesis was optimized to preserve the rGO film morphological and electron-transfer features and simultaneously integrate catalytic nCe. The films were characterized by microscopical (SEM), spectroscopical (EDX, Raman, and FTIR), and electrochemical techniques. The most performing film was integrated into a nitrocellulose substrate, and the complete sensor was assembled via a combination of xurography and stencil printing. The rGO-nCe sensor's catalytic activity was proved toward the detection of H2O2, obtaining sensitive determination (LOD = 0.3 µM) and an extended linear range (0.5-1500 µM). Eventually, the rGO-nCe sensor was challenged for the real-time continuous monitoring of hydrogen peroxide aerosol during no-touch fogging treatment conducted following the EU's recommendation for biocidal product use. Treatment effectiveness was proved toward three Lm strains characterized by different origins, i.e., type strain ATCC 7644, clinical strain 338, and food strain 641/6II. The sensor allows for discrimination and quantification treatments at different environmental biocidal amounts and fogging times, and correlates with the microbiological inhibition, promoting the proposed sensor as a useful tool to modulate and monitor no-touch treatments.


Disinfection , Graphite , Hydrogen Peroxide , Lasers , Listeria monocytogenes , Paper , Graphite/chemistry , Hydrogen Peroxide/chemistry , Listeria monocytogenes/drug effects , Listeria monocytogenes/isolation & purification , Disinfection/methods , Cerium/chemistry , Limit of Detection , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Catalysis
12.
Mikrochim Acta ; 191(7): 367, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38832980

An electrochemical aptasensor was used for the fast and sensitive detection of zearalenone (ZEN) based on the combination of Co3O4/MoS2/Au nanocomposites and the hybrid chain reaction (HCR). The glassy carbon electrode was coated with Co3O4/MoS2/Au nanomaterials to immobilize the ZEN-cDNA that had been bound with ZEN-Apt by the principle of base complementary pairing. In the absence of ZEN, the HCR could not be triggered because the ZEN-cDNA could not be exposed. After ZEN was added to the surface of the electrode, a complex structure was produced on the modified electrode by the combination of ZEN and ZEN-Apt. Therefore, the ZEN-cDNA can raise the HCR to produce the long-strand dsDNA structure. Due to the formation of dsDNA, the methylene blue (MB) could be inserted into the superstructure of branched DNA and the peak currents of the MB redox signal dramatically increased. So the concentration of ZEN could be detected by the change of signal intensity. Under optimized conditions, the developed electrochemical biosensing strategy showed an outstanding linear detection range of 1.0×10-10 mol/L to 1.0×10-6 mol/L, a low detection limit (LOD) of 8.5×10-11 mol/L with desirable selectivity and stability. Therefore, the fabricated platform possessed a great application potential in fields of food safety, medical detection, and drug analysis.


Electrochemical Techniques , Food Analysis , Hazard Analysis and Critical Control Points , Nanocomposites , Zearalenone , Zearalenone/analysis , Hazard Analysis and Critical Control Points/methods , Food Analysis/instrumentation , Food Analysis/methods , Nanocomposites/chemistry , Nanocomposites/standards , Electrodes , Gold/chemistry , Sensitivity and Specificity , Reproducibility of Results
13.
Sci Rep ; 14(1): 10479, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714793

Enterochromaffin (EC) cells located within the intestinal mucosal epithelium release serotonin (5-HT) to regulate motility tones, barrier function and the immune system. Electroanalytical methodologies have been able to monitor steady state basal extracellular 5-HT levels but are unable to provide insight into how these levels are influenced by key regulatory processes such as release and uptake. We established a new measurement approach, amperometry approach curve profiling, which monitors the extracellular 5-HT level at different electrode-tissue (E-T) distances. Analysis of the current profile can provide information on contributions of regulatory components on the observed extracellular 5-HT level. Measurements were conducted from ex vivo murine ileum and colon using a boron-doped diamond (BDD) microelectrode. Amperometry approach curve profiling coupled with classical pharmacology demonstrated that extracellular 5-HT levels were significantly lower in the colon when compared to the ileum. This difference was due to a greater degree of activity of the 5-HT transporter (SERT) and a reduced amount of 5-HT released from colonic EC cells. The presence of an inhibitory 5-HT4 autoreceptor was observed in the colon, where a 40% increase in extracellular 5-HT was the half maximal inhibitory concentration for activation of the autoreceptor. This novel electroanalytical approach allows estimates of release and re-uptake and their contribution to 5-HT extracellular concentration from intestinal tissue be obtained from a single series of measurements.


Colon , Ileum , Intestinal Mucosa , Serotonin , Serotonin/metabolism , Animals , Mice , Ileum/metabolism , Intestinal Mucosa/metabolism , Colon/metabolism , Enterochromaffin Cells/metabolism , Microelectrodes , Serotonin Plasma Membrane Transport Proteins/metabolism , Male , Electrochemical Techniques/methods , Mice, Inbred C57BL
14.
Anal Chim Acta ; 1306: 342585, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38692786

Herein, we developed a convenient and versatile dual-mode electrochemiluminescence (ECL) and photoelectrochemistry (PEC) sensing radar for the detection of Prostate-specific antigen (PSA), which has important implications for detection of low-abundance disease-associated proteins. Cerium-based metal-organic framework (Ce-MOFs) were firstly modified on the electrode, showing well ECL and PEC property. In particular, a unique multifunctional Au@CdS quantum dots (QDs) probe loaded numerous QDs and antibody was fabricated, not only displaying strong ECL and PEC signals, but also having specific recognition to PSA. After the signal probe was linked to the electrode by immune reaction, much amplified signals of ECL and PEC were generated for double-mode detection of PSA. Therefore, this work proposed a multifunctional Au@CdS QDs signal probe with excellent ECL and PEC performance, and developed an ultrasensitive photoelectric biosensing platform for dual-mode detection, which provides an effective method for health monitoring of cancer patients.


Cadmium Compounds , Electrochemical Techniques , Metal-Organic Frameworks , Prostate-Specific Antigen , Quantum Dots , Sulfides , Quantum Dots/chemistry , Cadmium Compounds/chemistry , Sulfides/chemistry , Humans , Prostate-Specific Antigen/analysis , Prostate-Specific Antigen/blood , Metal-Organic Frameworks/chemistry , Gold/chemistry , Cerium/chemistry , Biosensing Techniques , Photochemical Processes , Limit of Detection , Electrodes , Luminescent Measurements
15.
Anal Chim Acta ; 1306: 342609, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38692788

BACKGROUND: Accurate quantitative analysis of small molecule metabolites in biological samples is of great significance. Hydroxypolycyclic aromatic hydrocarbons (OH-PAHs) are metabolic derivatives of emerging pollutants, reflecting exposure to polycyclic aromatic hydrocarbons (PAHs). Macromolecules such as proteins and enzymes in biological samples will interfere with the accurate quantification of OH-PAHs, making direct analysis impossible, requiring a series of complex treatments such as enzymatic hydrolysis. Therefore, the development of matrix-compatible fiber coatings that can exclude macromolecules is of great significance to improve the ability of solid-phase microextraction (SPME) technology to selectively quantify small molecules in complex matrices and achieve rapid and direct analysis. RESULTS: We have developed an innovative coating with a stable macromolecular barrier using electrospinning and flexible filament winding (FW) technologies. This coating, referred to as the hollow fibrous covalent organic framework@polyionic liquid (F-COF@polyILs), demonstrates outstanding conductivity and stability. It accelerates the adsorption equilibrium time (25 min) for polar OH-PAHs through electrically enhanced solid-phase microextraction (EE-SPME) technology. Compared to the powder form, F-COF@polyILs coating displays effective non-selective large-size molecular sieving. Combining gas chromatography-tandem triple quadrupole mass spectrometry (GC-MS/MS), we have established a simple, efficient quantitative analysis method for OH-PAHs with a low detection limit (0.008-0.05 ng L-1), wide linear range (0.02-1000 ng L-1), and good repeatability (1.0%-7.3 %). Experimental results show that the coated fiber exhibits good resistance to matrix interference (2.5%-16.7 %) in complex biological matrices, and has been successfully used for OH-PAHs analysis in human urine and plasma. SIGNIFICANCE: FW technology realizes the transformation of the traditional powder form of COF in SPME coating to a uniform non-powder coating, giving its ability to exclude large molecules in complex biological matrices. A method for quantitatively detecting OH-PAHs in real biological samples was also developed. Therefore, the filament winding preparation method for F-COF@polyILs coated fibers, along with fibrous COFs' morphology control, has substantial implications for efficiently extracting target compounds from complex matrices.


Solid Phase Microextraction , Solid Phase Microextraction/methods , Metal-Organic Frameworks/chemistry , Polycyclic Aromatic Hydrocarbons/analysis , Polycyclic Aromatic Hydrocarbons/isolation & purification , Macromolecular Substances/chemistry , Limit of Detection , Adsorption , Electrochemical Techniques/methods
16.
Anal Chim Acta ; 1306: 342613, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38692794

Glucose detection is of significant importance in providing information to the human health management. However, conventional enzymatic glucose sensors suffer from a limited long-term stability due to the losing activity of the enzymes. In this work, the AuNi bimetallic aerogel with a well-defined nanowire network is synthesized and applied as the sensing nanomaterial in the non-enzymatic glucose detection. The three-dimensional (3D) hierarchical porous structure of the AuNi bimetallic aerogel ensures the high sensitivity of the sensor (40.34 µA mM-1 cm-2). Theoretical investigation unveiled the mechanism of the boosting electrocatalytic activity of the AuNi bimetallic aerogel toward glucose. A better adhesion between the sensing nanomaterial and the screen-printing electrodes (SPEs) is obtained after the introduction of Ni. On the basis of a wide linearity in the range of 0.1-5 mM, an excellent selectivity, an outstanding long-term stability (90 days) as well as the help of the signal processing circuit and an M5stack development board, the as-prepared glucose sensor successfully realizes remote monitoring of the glucose concentration. We speculate that this work is favorable to motivating the technological innovations of the non-enzymatic glucose sensors and intelligent sensing devices.


Biosensing Techniques , Electrochemical Techniques , Gels , Glucose , Gold , Nickel , Biosensing Techniques/methods , Nickel/chemistry , Gels/chemistry , Gold/chemistry , Glucose/analysis , Electrodes , Nanowires/chemistry , Humans , Limit of Detection
17.
Mikrochim Acta ; 191(6): 298, 2024 05 06.
Article En | MEDLINE | ID: mdl-38709403

As a real-time fluid biopsy method, the detection of circulating tumor cells (CTCs) provides important information for the early diagnosis, precise treatment, and prognosis of cancer. However, the low density of CTCs in the peripheral blood hampers their capture and detection with high sensitivity and selectivity using currently available methods. Hence, we designed a sandwich-type electrochemical aptasensor that utilizes holothurian-shaped AuPd nanoparticles (AuPd HSs), tetrahedral DNA nanostructures (TDNs), and CuPdPt nanowire networks (NWs) interwoven with a graphdiyne (GDY) sheet for ultrasensitive non-destructive detection of MCF-7 breast cancer cells. CuPdPt NW-GDY effectively enhanced the electron transfer rate and coupled with the loaded TDNs. The TDNs could capture MCF-7 cells with precision and firmness, and the resulting composite complex was combined with AuPd HSs to form a sandwich-type structure. This novel aptasensor showed a linear range between 10 and 106 cells mL-1 and an ultralow detection limit of 7 cells mL-1. The specificity, stability, and repeatability of the measurements were successfully verified. Moreover, we used benzonase nuclease to achieve non-destructive recovery of cells for further clinical studies. According to the results, our aptasensor was more sensitive measuring the number of CTCs than other approaches because of the employment of TDNs, CuPdPt NW-GDY, and AuPd HSs. We designed a reliable sensor system for the detection of CTCs in the peripheral blood, which could serve as a new approach for cancer diagnosis at an early stage.


Aptamers, Nucleotide , Biosensing Techniques , DNA , Electrochemical Techniques , Gold , Limit of Detection , Metal Nanoparticles , Neoplastic Cells, Circulating , Palladium , Neoplastic Cells, Circulating/pathology , Humans , MCF-7 Cells , Metal Nanoparticles/chemistry , Electrochemical Techniques/methods , Aptamers, Nucleotide/chemistry , Gold/chemistry , DNA/chemistry , Biosensing Techniques/methods , Palladium/chemistry
18.
Mikrochim Acta ; 191(6): 306, 2024 05 07.
Article En | MEDLINE | ID: mdl-38713247

For early diabetes identification and management, the progression of an uncomplicated and exceedingly responsive glucose testing technology is crucial. In this study, we present a new sensor incorporating a composite of metal organic framework (MOF) based on cobalt, coated with boronic acid to facilitate selective glucose binding. Additionally, we successfully employed a highly sensitive electro-optical immunosensor for the detection of subtle changes in concentration of the diabetes biomarker glycated haemoglobin (HbA1c), using zeolitic imidazolate framework-67 (ZIF-67) coated with polydopamine which further modified with boronic acid. Utilizing the polymerization characteristics of dopamine and the NH2 groups, a bonding structure is formed between ZIF-67 and 4-carboxyphenylboronic acid. ZIF-67 composite served as an effective substrate for immobilising 4-carboxyphenylboronic acid binding agent, ensuring precise and highly selective glucose identification. The sensing response was evaluated through both electrochemical and optical methods, confirming its efficacy. Under optimized experimental condition, the ZIF-67 based sensor demonstrated a broad detection range of 50-500 mg dL-1, a low limit of detection (LOD) of 9.87 mg dL-1 and a high correlation coefficient of 0.98. Furthermore, the 4-carboxyphenylboronic acid-conjugated ZIF-67-based sensor platform exhibited remarkable sensitivity and selectivity in optical-based detection for glycated haemoglobin within the clinical range of 4.7-11.3%, achieving a LOD of 3.7%. These findings highlight the potential of the 4-carboxyphenylboronic acid-conjugated ZIF-67-based electro-optical sensor as a highly sensitive platform for diabetes detection.


Blood Glucose , Boronic Acids , Diabetes Mellitus , Glycated Hemoglobin , Imidazoles , Limit of Detection , Metal-Organic Frameworks , Zeolites , Boronic Acids/chemistry , Zeolites/chemistry , Metal-Organic Frameworks/chemistry , Imidazoles/chemistry , Humans , Glycated Hemoglobin/analysis , Blood Glucose/analysis , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis , Nanoparticles/chemistry , Biosensing Techniques/methods , Indoles/chemistry , Polymers/chemistry , Electrochemical Techniques/methods
19.
Mikrochim Acta ; 191(6): 309, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714599

Copper-doped carbon dots and aminated carbon nanotubes (Cu-CDs/NH2-CNTs) nanocomposites were synthesized by a one-step growth method, and the composites were characterized for their performance. An electrochemical sensor for sensitive detection of bisphenol A (BPA) was developed for using Cu-CDs/NH2-CNTs nanocomposites modified with glassy carbon electrodes (GCE). The sensor exhibited an excellent electrochemical response to BPA in 0.2 M PBS (pH 7.0) under optimally selected conditions. The linear range of the sensor for BPA detection was 0.5-160 µM, and the detection limit (S/N = 3) was 0.13 µM. Moreover, the sensor has good interference immunity, stability and reproducibility. In addition, the feasibility of the practical application of the sensor was demonstrated by the detection of BPA in bottled drinking water and Liu Yang River water.


Benzhydryl Compounds , Copper , Electrochemical Techniques , Electrodes , Limit of Detection , Nanotubes, Carbon , Phenols , Water Pollutants, Chemical , Benzhydryl Compounds/analysis , Phenols/analysis , Phenols/chemistry , Nanotubes, Carbon/chemistry , Copper/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Water Pollutants, Chemical/analysis , Drinking Water/analysis , Quantum Dots/chemistry , Carbon/chemistry , Rivers/chemistry
20.
Anal Chim Acta ; 1307: 342627, 2024 Jun 08.
Article En | MEDLINE | ID: mdl-38719406

BACKGROUND: Hydrogen peroxide (H2O2) is an important reactive oxygen species (ROS) molecule involved in cell metabolism regulation, transcriptional regulation, and cytoskeleton remodeling. Real-time monitoring of H2O2 levels in live cells is of great significance for disease prevention and diagnosis. RESULTS: We utilized carbon cloth (CC) as the substrate material and employed a single-atom catalysis strategy to prepare a flexible self-supported sensing platform for the real-time detection of H2O2 secreted by live cells. By adjusting the coordination structure of single-atom sites through P and S doping, a cobalt single-atom nanoenzyme Co-NC/PS with excellent peroxidase-like activity was obtained. Furthermore, we explored the enzyme kinetics and possible catalytic mechanism of Co-NC/PS. Due to the excellent flexibility, high conductivity, strong adsorption performance of carbon cloth, and the introduction of non-metallic atom-doped active sites, the developed Co-NC/PS@CC exhibited ideal sensing performance. Experimental results showed that the linear response range for H2O2 was 1-17328 µM, with a detection limit (LOD) of 0.1687 µM. Additionally, the sensor demonstrated good reproducibility, repeatability, anti-interference, and stability. SIGNIFICANCE: The Co-NC/PS@CC prepared in this study has been successfully applied for detecting H2O2 secreted by MCF-7 live cells, expanding the application of single-atom nanoenzymes in live cell biosensing, with significant implications for health monitoring and clinical diagnostics.


Cobalt , Electrochemical Techniques , Hydrogen Peroxide , Hydrogen Peroxide/chemistry , Hydrogen Peroxide/analysis , Cobalt/chemistry , Humans , Electrochemical Techniques/methods , MCF-7 Cells , Carbon/chemistry , Limit of Detection , Biosensing Techniques/methods
...