Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.396
Filter
1.
Anal Chem ; 96(24): 9969-9974, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38847356

ABSTRACT

Epinephrine (EP) is an essential catecholamine in the human body. Currently, most EP detection methods are not suitable for in vivo detection due to material limitations. An organic small molecule fluorescent probe based on a chemical cascade reaction for the detection of EP was designed. Anionic heptamethine cyanine dye was selected as a fluorescent dye because of its NIR fluorescence emission with excellent biocompatibility. The secondary amine of EP nucleophilically attacks the carbonate of the probe with its stronger nucleophilicity and further undergoes intramolecular nucleophilic cyclization to release the fluorophore. Other substances containing only primary amines or no ß-OH lack reaction competitiveness due to their weaker nucleophilicity or inability to undergo further cyclization. The fluorescence recovery of the probe was linearly related to the EP concentration of 2-75 µmol/L. The detection limit was 0.4 µmol/L. The recovery rate was 94.78-111.32%. Finally, we successfully achieved bioimaging of EP in living cells and EP analogue in nematodes.


Subject(s)
Carbocyanines , Epinephrine , Fluorescent Dyes , Fluorescent Dyes/chemistry , Fluorescent Dyes/chemical synthesis , Humans , Epinephrine/analysis , Carbocyanines/chemistry , Animals , Optical Imaging , Anions/chemistry , Anions/analysis , Caenorhabditis elegans , Limit of Detection , Infrared Rays , HeLa Cells , Molecular Structure
2.
Talanta ; 276: 126274, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38788379

ABSTRACT

A novel electrochemical biosensor was developed for the detection of epinephrine (EP) by immobilizing double-strand DNA (dsDNA) bound with copper ions on a gold electrode (Cu2+/dsDNA/MCH/AuE). The electrochemical behavior of EP at Cu2+/dsDNA/MCH/AuE was examined, and the results demonstrated a significant enhancement in the electrocatalytic oxidation peak current of EP due to the formation of a stable G-Cu(II)-G sandwich structure between Cu2+ and guanine at the modified electrode. The modification process of the electrode was characterized by scanning electron microscopy, infrared spectroscopy, electrochemical impedance spectroscopy, and differential pulse voltammetry. A study on the effect of pH in phosphate buffer solution on the electrochemical oxidation of EP indicated that the catalytic oxidation process was pH-dependent. A plot of catalytic current versus EP concentration exhibited a dual-linear relationship within two ranges: 1.0-12.5 µM and 12.5-1000.0 µM, with correlation coefficients of 0.995 and 0.997, respectively. The limit of detection was determined to be 47 nM (S/N = 3). According to the calculated Hill coefficient (0.99), it can be concluded that the electrocatalytic process followed the Michaelis-Menten kinetic mechanism. The maximum catalytic current Im was 25 µA, while the apparent Michaelis-Menten constant Km was 1.425 mM. These findings indicated excellent electrocatalytic activity of the modified electrode towards oxidation of EP. The developed biosensor successfully detected EP in spiked mouse serum as well as epinephrine hydrochloride injection with high selectivity, sensitivity, stability, and accuracy.


Subject(s)
Biosensing Techniques , Copper , DNA , Electrochemical Techniques , Electrodes , Epinephrine , Gold , Epinephrine/analysis , Epinephrine/blood , Copper/chemistry , Biosensing Techniques/methods , DNA/chemistry , Electrochemical Techniques/methods , Gold/chemistry , Limit of Detection , Animals , Oxidation-Reduction , Hydrogen-Ion Concentration
3.
Talanta ; 275: 126178, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38692052

ABSTRACT

This study introduces a straightforward method for depositing InZnSnO films onto flexible polyimide substrates at room temperature, enabling their application in electrochemical pH sensing and the detection of epinephrine. A comprehensive analysis of these sensing films, spanning structural, morphological, compositional, and profiling characteristics, was conducted using diverse techniques, including X-ray diffraction, atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectroscopy. The investigation into the influence of oxygen flow rates on the performance of InZnSnO sensitive films revealed a significant correlation between their structural properties and sensing capabilities. Notably, exposure to an oxygen flow rate of 30/2 (Ar/O2) the ratio of resulted in the InZnSnO sensitive film demonstrating outstanding pH sensitivity at 59.58 mV/pH within a broad pH range of 2-12, surpassing the performance observed with other oxygen flow rates. Moreover, under this specific condition, the film exhibited excellent stability, with a minimal drift rate of 0.14 mV/h at pH 7 and a low hysteresis voltage of 1.8 mV during a pH cycle of 7 â†’ 4→7 â†’ 10→7. Given the critical role of epinephrine in mammalian central nervous and hormone systems, monitoring its levels is essential for assessing human health. To facilitate the detection of epinephrine, we utilized the carboxyl group of 4-formylphenylboronic acid to enable a reaction with the amino group of the 3-aminopropyltriethoxysilane-coated InZnSnO film. Through optimization, the resulting InZnSnO-based flexible sensor displayed a broad and well-defined linear relationship within the concentration range of 10-7 to 0.1 µM. In practical applications, this sensor proved effective in analyzing epinephrine in human serum, showcasing notable selectivity, stability, and reproducibility. The promising outcomes of this study underscore the potential for future applications, leveraging the advantages of electrochemical sensors, including affordability, rapid response, and user-friendly operation.


Subject(s)
Epinephrine , Transistors, Electronic , Epinephrine/analysis , Epinephrine/chemistry , Hydrogen-Ion Concentration , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Oxygen/chemistry , Oxygen/analysis , Humans , Limit of Detection , Zinc Oxide/chemistry
4.
ACS Appl Bio Mater ; 7(5): 3271-3282, 2024 05 20.
Article in English | MEDLINE | ID: mdl-38654595

ABSTRACT

A thiazole-based probe, N'-((2-aminothiazol-5-yl)methylene)benzohydrazide (TBH), has been efficiently synthesized and characterized for the selective and sensitive detection of the neurotransmitter epinephrine (EP). The sensing strategy is based on the use of TBH for sequential colorimetric sensing of Ag+ and EP via in situ formation of Ag nanoparticles (Ag NPs) from the TBH-Ag+ complex. The generated Ag NPs lead to a bathochromic shift in absorption maximum and a change in color of the solution from light brown to reddish brown. TBH-Ag+ shows remarkable selectivity toward EP versus other drugs, common cations, anions, and some biomolecules. Moreover, TBH-Ag+ has a low detection limit for EP at 1.2 nM. The coordination of TBH-Ag+ has been proposed based on Job's plot, Fourier transform infrared spectroscopy (FT-IR), high-resolution mass spectrometry (HRMS), 1H NMR titration, X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray analysis (EDAX), and density functional theory (DFT) studies. The composition and morphology of the generated Ag NPs have been analyzed by XPS, scanning electron microscopy (SEM), transmission electron microscopy (TEM), and dynamic light scattering (DLS). The proposed sensing mechanism for EP has been supported by XPS of Ag after the reaction. Further, the sensitivity of TBH-Ag+ toward EP in brain tissues of an Alzheimer's disease model of mouse has been evaluated. A thorough comparison was done for evaluation of the proposed method.


Subject(s)
Alzheimer Disease , Brain , Colorimetry , Epinephrine , Silver , Thiazoles , Alzheimer Disease/diagnostic imaging , Alzheimer Disease/diagnosis , Alzheimer Disease/metabolism , Silver/chemistry , Animals , Mice , Epinephrine/analysis , Thiazoles/chemistry , Brain/metabolism , Brain/diagnostic imaging , Materials Testing , Disease Models, Animal , Biocompatible Materials/chemistry , Biocompatible Materials/chemical synthesis , Particle Size , Metal Nanoparticles/chemistry , Molecular Structure , Ions/chemistry
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 315: 124254, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38593542

ABSTRACT

The rapid detection of epinephrine (EPI) in serum holds immense importance in the early disease diagnosis and regular monitoring. On the basis of the coordination post-synthetic modification (PSM) strategy, a Eu3+ functionalized ZnMOF (Eu3+@ZnMOF) was fabricated by anchoring the Eu3+ ions within the microchannels of ZnMOF as secondary luminescent centers. Benefiting from two independent luminescent centers, the prepared Eu3+@ZnMOF shows great potential as a multi-signal self-calibrating luminescent sensor in visually and efficiently detecting serum EPI levels, with high reliability, fast response time, excellentrecycleability, and low detection limits of 17.8 ng/mL. Additionally, an intelligent sensing system was designed in accurately and reliably detecting serum EPI levels, based on the designed self-calibrating logic gates. Furthermore, the possible sensing mechanisms were elucidated through theoretical calculations as well as spectral overlaps. This work provides an effective and promising strategy for developing MOFs-based self-calibrating intelligent sensing platforms to detect bioactive molecules in bodily fluids.


Subject(s)
Epinephrine , Europium , Epinephrine/analysis , Epinephrine/blood , Europium/chemistry , Limit of Detection , Humans , Calibration , Luminescent Measurements/methods , Spectrometry, Fluorescence , Logic
6.
Ars pharm ; 65(2): 98-106, mar. 2024. tab
Article in Spanish | IBECS | ID: ibc-231946

ABSTRACT

Introducción: El bitartrato de epinefrina, también conocido como epinefrina, es un ingrediente farmacéutico importante en el tratamiento de diversas enfermedades, pero su medición precisa es esencial para garantizar la seguridad del medicamento. La Farmacopea de los Estados Unidos (USP) establece los estándares para su análisis, pero la elección del método afecta la precisión de las mediciones. Este estudio investiga cómo los diferentes métodos afectan la medición del bitartrato de epinefrina según las versiones USP-43 y USP-44, que tienen implicaciones significativas para la calidad y la regulación de los medicamentos en el campo. Método: Se eligieron el método volumétrico y el método cromatográfico para comparación. Se utilizaron muestras de epinefrina bitartrato de alta pureza que cumplían con los estándares de la USP-43 y USP-44.Resultados: Los resultados obtenidos por ambos métodos se comparan entre sí y se evalúan según los límites de especificación definidos por USP-43 y USP-44. Los valores obtenidos para algunos parámetros, como la concentración y la pureza del bitartrato de epinefrina, varían considerablemente entre los distintos métodos analíticos. Conclusiones: Este estudio destaca la importancia de una cuidadosa selección del método analítico al evaluar el bitartrato de epinefrina según las directrices USP-43 y USP-44. La elección de la tecnología afecta a los resultados y, por tanto, a la calidad y seguridad de los productos farmacéuticos que contienen esta sustancia. Se recomienda validar el método en cada laboratorio y comparar los resultados con los estándares USP. (AU)


Introduction: Epinephrine bitartrate, also known as epinephrine, is an important pharmaceutical ingredient in the treatment of various diseases, but its accurate measurement is essential to ensure the safety of the drug. The United States Pharmacopeia (USP) sets the standards for its analysis, but the choice of method affects the precision of the measurements. This study investigates how different methods affect the measurements of epinephrine bitartrate based on USP-43 and USP-44, which have significant implications for drug quality and regulation in the field. Method: The volumetric method and chromatographic method were chosen for comparison. High-purity epineph-rine bitartrate samples that met USP-43 and USP-44 standards were used. Results: The results obtained by both methods are compared with and evaluated according to the specification lim-its defined by USP-43 and USP-44. The values obtained for some parameters, such as the concentration and purity of epinephrine tartrate, vary considerably between the different analytical methods. Conclusions: This study highlights the importance of carefully selecting analytical methods when evaluating epi-nephrine tartrate according to USP-43 and USP-44 guidelines. The choice of technology affects the results and, therefore, the quality and safety of the pharmaceutical products containing this substance. It is recommended to validate the method in each laboratory and compare the results with USP standards. (AU)


Subject(s)
Epinephrine/pharmacology , Epinephrine/analysis , Titrimetry , Chromatography , Pharmacopoeias as Topic
7.
J Nat Prod ; 86(11): 2592-2619, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37856864

ABSTRACT

Catecholamines (CAs) are aromatic amines containing a 3,4-dihydroxyphenyl nucleus and an amine side chain. Representative CAs included the endogenous neurotransmitters epinephrine, norepinephrine, and dopamine. CAs and their derivatives are good resources for the development of sympathomimetic or central nervous system drugs, while they also provide ligands important for G-protein coupled receptor (GPCR) research. CAs are of broad interest in the fields of chemical, biological, medical, and material sciences due to their high adhesive capacities, chemical reactivities, metal-chelating abilities, redox activities, excellent biocompatibilities, and ease of degradability. Herein, we summarize CAs derivatives isolated and identified from microorganisms, plants, insects, and marine invertebrates in recent decades, alongside their wide range of reported biological activities. The aim of this review is to provide an overview of the structural and biological diversities of CAs, the regularity of their natural occurrences, and insights toward future research and development pertinent to this important class of naturally occurring compounds.


Subject(s)
Catecholamines , Norepinephrine , Catecholamines/analysis , Catecholamines/chemistry , Catecholamines/physiology , Norepinephrine/analysis , Epinephrine/analysis , Dopamine , Amines
8.
Talanta ; 259: 124531, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37080073

ABSTRACT

This article demonstrates an array of inexpensive molecularly imprinted microneedle platforms for the multiplexed electrochemical detection of pH, epinephrine, dopamine, and lactate biomarkers in human sweat. The multiplexed sensors were fabricated via layer-by-layer (LbL) assembly on a polydimethylsiloxane (PDMS) microneedle platform coated with a conductive PDMS/carbon nanotube (CNT)/cellulose nanocrystal (CNC) composite (PDMS/CNT/CNC@PDMS). The pH sensor was comprised of a pH-responsive polyaniline (PANI)/CNT/CNC/silver nanoparticle (AgNP) composite layer. The epinephrine, dopamine, and lactate sensors consisted of an additional epinephrine, dopamine, or lactate-imprinted PANI-co-3-aminophenylboronic acid (PBA)/gold nanoparticle (AuNP) layer atop the PANI/CNT/CNC/AgNP composite layer. Each sensor rapidly (∼2 min) and selectively responded to their target analytes, with excellent precision between scans. The limits of detection (LOD) for the epinephrine, dopamine, and lactate sensors were 0.0007 ± 0.0002 µM, 2.11 ± 0.05 nM, and 0.07 ± 0.07 mM, respectively. The pH sensor accurately responded to a pH range of 4.25-10. The applicability of the sensor platforms were successfully verified through quantification of pH, epinephrine, dopamine, and lactate in a human sweat sample, showing promise for use as a wearable, point of need (PON) sensor for sweat analytics.


Subject(s)
Metal Nanoparticles , Molecular Imprinting , Humans , Sweat/chemistry , Dopamine/analysis , Gold/chemistry , Electrochemical Techniques , Silver/analysis , Cellulose , Lactic Acid/analysis , Epinephrine/analysis
9.
Environ Pollut ; 309: 119822, 2022 Sep 15.
Article in English | MEDLINE | ID: mdl-35870527

ABSTRACT

Air pollution is a major trigger of chronic obstructive pulmonary disease (COPD). Dysregulation of the neuroendocrine hypothalamic-pituitary-adrenal (HPA) and sympathetic-adrenal medullary (SAM) axes is essential in progression of COPD. However, it is not clear whether air pollution exposure is associated with neuroendocrine responses in individuals with and without COPD. Based on a panel study of 51 stable COPD patients and 78 non-COPD participants with 384 clinical visits, we measured the morning serum levels of corticotropin-releasing hormone (CRH), adrenocorticotropic hormone (ACTH), cortisol, norepinephrine, and epinephrine as indicators of stress hormones released from the HPA and SAM axes. Ambient nitrogen dioxide (NO2), fine particulate matter (PM2.5), and meteorological conditions were continuously monitored at the station from 2 weeks before the start of clinical visits. Linear mixed-effects models were used to estimate associations between differences in stress hormones following an average of 1-14-day exposures to NO2 and PM2.5. The average 1 day air pollutant levels prior to the clinical visits were 24.4 ± 14.0 ppb for NO2 and 55.6 ± 41.5 µg/m3 for PM2.5. We observed significant increases in CRH, ACTH, and norepinephrine, and decreases in cortisol and epinephrine with interquartile range increase in the average NO2 and PM2.5 concentrations in all participants. In the stratified analyses, we identified significant between-group difference in epinephrine following NO2 exposure in individuals with and without COPD. These results may suggest the susceptibility of COPD patients to the neuroendocrine responses associated with short-term air pollution exposure.


Subject(s)
Air Pollutants , Air Pollution , Pulmonary Disease, Chronic Obstructive , Adrenocorticotropic Hormone/analysis , Air Pollutants/analysis , Air Pollution/analysis , Beijing , Environmental Exposure/analysis , Epinephrine/analysis , Humans , Hydrocortisone , Nitrogen Dioxide/analysis , Norepinephrine/analysis , Particulate Matter/analysis
10.
Anal Bioanal Chem ; 414(2): 1163-1176, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34718838

ABSTRACT

Surface-enhanced Raman spectroscopy (SERS) is a powerful analytical technique capable of increasing the Raman signal of an analyte using specific nanostructures. The close contact between those nanostructures, usually a suspension of nanoparticles, and the molecule of interest produces an important exaltation of the intensity of the Raman signal. Even if the exaltation leads to an improvement of Raman spectroscopy sensitivity, the complexity of the SERS signal and the numbers of parameters to be controlled allow the use of SERS for detection rather than quantification. The aim of this study was to develop a robust discriminative and quantitative analysis in accordance with pharmaceutical standards. In this present work, we develop a discriminative and quantitative analysis based on the previous optimized parameters obtained by the design of experiments fixed for norepinephrine (NOR) and extended to epinephrine (EPI) which are two neurotransmitters with very similar structures. Studying the short evolution of the Raman signal intensity over time coupled with chemometric tools allowed the identification of outliers and their removal from the data set. The discriminant analysis showed an excellent separation of EPI and NOR. The comparative analysis of the data showed the superiority of the multivariate analysis after logarithmic transformation. The quantitative analysis allowed the development of robust quantification models from several gold nanoparticle batches with limits of quantification of 32 µg/mL for NOR and below 20 µg/mL for EPI even though no Raman signal is observable for such concentrations. This study improves SERS analysis over ultrasensitive detection for discrimination and quantification using a handheld Raman spectrometer.


Subject(s)
Epinephrine/analysis , Gold/chemistry , Metal Nanoparticles/chemistry , Norepinephrine/analysis , Spectrum Analysis, Raman/methods
11.
Biosensors (Basel) ; 11(8)2021 Aug 19.
Article in English | MEDLINE | ID: mdl-34436086

ABSTRACT

This work demonstrates the analysis of epinephrine (EP) and uric acid (UA) in a single drop (the volume of the test solution was only 50 µL) using a screen-printed carbon electrode (SPCE) sensor and square-wave voltammetry (SWV). The limit of detection, limit of quantification, linearity, accuracy, precision, and robustness were validated. The normality of the experimental data was tested and confirmed for both methods. Heteroscedasticity was checked by residual analysis followed by a statistical F-test. The latter was confirmed for both analytes. The low relative standard deviations (RSD) at all calibration points and repetitive slopes justified the use of a calibration curve; therefore, the standard addition methodology was avoided (the latter is common in electroanalysis, but time-consuming). Since the conditions for using an ordinary least squares (OLS) regression were not met, weighted linear regression (WLR) was used to improve the accuracy of the analytical results at low concentrations of the analytes. In this manner, the best weighted model was determined and used for the quantification. A comparison was made between the OLS and WLR methods to show the necessity of using the WLR method for EP and UA analysis. The newly developed and validated methods were also shown to be effective in the analysis of real samples. The content of EP in an EP auto-injector and UA in human urine was tested by employing the best weighted model. For EP and UA, the accuracy in terms of the average recovery value was 101.01% and 94.35%, and precision in terms of RSD was 5.65% and 2.75%, respectively. A new analytical methodology is presented that uses a low volume (a single drop), and it offers the advantage of electroanalysis for on-site analysis, where conventional chromatographic techniques cannot be easily employed. Furthermore, the developed technique has additional advantages in terms of speed, cost, and miniaturization.


Subject(s)
Electrodes , Epinephrine/analysis , Uric Acid/analysis , Ascorbic Acid , Biosensing Techniques , Catalysis , Electrochemical Techniques , Electrochemistry , Humans , Nanotubes, Carbon
12.
ACS Appl Mater Interfaces ; 13(29): 34572-34583, 2021 Jul 28.
Article in English | MEDLINE | ID: mdl-34255481

ABSTRACT

The effective and precise detection of cancer and neurotransmitter biomarkers including folic acid (FA), dopamine (DA), and epinephrine (EP) are essential for early detection and diagnosis of cancer and neurological disorders and for the development of new drugs. However, it remains challenging to detect FA, DA, and EP with high selectivity and sensitivity with a single material. Herein, we report a photoluminescence (PL)-based selective sensing of FA, DA, and EP with nitrogen-doped graphene quantum dots (NGQDs) synthesized from biocompatible chitosan under ambient conditions using atmospheric pressure microplasmas. By regulating the pH, the selective detection is achieved in broad ranges from 0.8 to 80 µM for FA and 0.4 to 100 µM for both DA and EP with the very low limits of detections of 81.7, 57.8, and 16.7 nM for FA, DA, and EP, respectively. The developed PL sensing method shows the high throughput of 5000 detections per hour. Moreover, highly stable colloidal NGQD dispersion with 100 µg/mL concentration for at least 100 PL detections is produced in 1 h by a single microplasma, and the process is scalable. The mechanisms of the outstanding performance are related to the enhanced, size-dependent π-π stacking attraction between the NGQDs and the pH-regulated chemical states of the analytes and the associated pH-specific photo-induced electron transfer and PL.


Subject(s)
Biomarkers, Tumor/analysis , Graphite/chemistry , Luminescent Agents/chemistry , Neurotransmitter Agents/analysis , Quantum Dots/chemistry , Dopamine/analysis , Epinephrine/analysis , Folic Acid/analysis , Limit of Detection , Luminescent Measurements , Nitrogen/chemistry
13.
Food Chem ; 356: 129680, 2021 Sep 15.
Article in English | MEDLINE | ID: mdl-33819787

ABSTRACT

Liquid chromatography coupled with tandem mass spectrometry was employed for the detection of pesticides (thiamethoxam, lambda-cyhalothrin, deltamethrin, and metalaxyl) and their metabolites in Raphanus sativus var. longipinnatus exposed to these compounds under experimental conditions. Metalaxyl (0.008 mg/kg), metalaxyl acid (0.009 mg/kg), and (+)-trans-chrysanthemic acid (0.098 mg/kg) were identified in the plants exposed to the individual pesticides and their metabolites. Non-targeted analysis revealed the presence of thiamethoxam, lambda-cyhalothrin, and deltamethrin metabolites in plants exposed to these substances, despite the fact that the pesticide concentrations were below the analytical method's limit of quantification (0.005-0.006 mg/kg). Based on the non-targeted screening, non-specific (leucine and tyramine) and specific (epinephrine, dopamine, tryptamine, and serotonin) markers of plant exposure to the mentioned stress-inducing compounds were detected. These findings prove that non-targeted analysis is an indispensable tool for determining plants' exposure to pesticides, even when the parent compound has been completely metabolized.


Subject(s)
Chromatography, High Pressure Liquid , Metabolome , Pesticides/pharmacology , Raphanus/metabolism , Tandem Mass Spectrometry , Epinephrine/analysis , Epinephrine/isolation & purification , Leucine/analysis , Leucine/isolation & purification , Nitriles/pharmacology , Pyrethrins/pharmacology , Raphanus/drug effects , Solid Phase Extraction , Thiamethoxam/pharmacology
14.
Nanotechnology ; 32(26)2021 Apr 06.
Article in English | MEDLINE | ID: mdl-33730698

ABSTRACT

Herein, Ti3C2TxMXene/N-doped reduced graphene oxide (MXene/N-rGO) composite was employed as the electrocatalyst to construct a new electrochemical sensing platform for the determination of adrenaline (AD). The MXene/N-rGO was synthesized via a facile one-step hydrothermal method, where ethylenediamine acted as a reducing agent and N source. The doped N in rGO served as a bridge between MXene and rGO through tight hydrogen bonds. Scanning electron microscopy showed that large numbers of MXenes with accordion-like morphology were distributed on the surface of the N-rGO. The MXene/N-rGO composite displayed a synergetic catalytic effect for oxidizing AD, originating from the unique catalytic activity of N-rGO and the large surface area and satisfactory conductivity of MXene. These characteristics of composite material led to a remarkable effect on signal amplification for the detection of AD, with a wide linear range from 10.0 nM to 90.0µM and a low detection limit of 3.0 nM based on a signal to noise ratio of 3. Moreover, the MXene/N-rGO electrode displayed good stability, repeatability, and reproducibility. Additionally, the proposed sensor was successfully applied for voltammetric sensing of AD in urine with recoveries from 97.75% to 103.0%.


Subject(s)
Biosensing Techniques , Epinephrine/analysis , Graphite/chemical synthesis , Carbon/chemistry , Electrochemical Techniques , Nitrogen/chemistry , Silicon/chemistry , Titanium/chemistry
15.
Mater Sci Eng C Mater Biol Appl ; 119: 111557, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33321621

ABSTRACT

For this study, three novel types of sensors comprised of CoAl-layered double oxyhydroxide (CoAl-LDH), CoAl-LDH/reduced graphene oxide (rGO), and CoAl-OOH/rGO nanosheets were successfully fabricated on glassy carbon electrodes (GCEs) and employed for the electrochemical detection of epinephrine (EP) and acetaminophen (AC). Interestingly, we found that the CoAl-OOH/rGO/GCE was more suitable for the determination of EP and AC in contrast to the CoAl-LDH and CoAl-OOH/rGO sensors. Differential pulse voltammetry results revealed that the CoAl-OOH/rGO/GCE delivered excellent electrocatalytic activity. The sensitivities and detection limits for the simultaneous measurement of EP and AC were 12.2 µA µM-1 cm-2, 0.023 µM L-1, and 4.87 µA µM-1 cm-2, 0.058 µM L-1, respectively. Especially, the as-obtained CoAl-OOH/rGO/GCE was successfully utilized for the detection in pharmaceutical samples and biological fluids with satisfactory results. Owing to its outstanding electrocatalytic activity and superior sensitivity, the CoAl-OOH/rGO/GCE could be beneficial to construct a promising electrochemical sensor for the detection of EP and AC.


Subject(s)
Graphite , Pharmaceutical Preparations , Acetaminophen , Coal , Electrochemical Techniques , Electrodes , Epinephrine/analysis
16.
Food Chem ; 335: 127658, 2021 Jan 15.
Article in English | MEDLINE | ID: mdl-32731124

ABSTRACT

Raphanus sativus var. longipinnatus, was exposed under experimental conditions to herbicides: rimsulfuron (RIM), administrated as (1) pure substance, (2) in commercially available formulation (RIMEL), (3) its degradation product: 4,6-dimethoxypyrimidin-2-amine (2ADP), (4) mesotrione (MES), (5) sulcotrione (SUL). Profiling and fingerprinting strategies, conducted by LC-MS/MS-FL, were employed to find markers of plant exposure to herbicide stress. The presence ofRIM metabolite in the tissues of plant exposed to this herbicide proved that it is necessary to determine both parent compound and its by-products to obtain reliable information on plant exposure to agrochemicals. A higher content of normetanephrine (NMN) (18-175%) and lower content of tyramine (TYR) (49-75%) and epinephrine (E) (75-83%) was observed in plant tissues exposed to RIM and 2ADP in comparison to blank sample. Therefore, NMN, TRY and E may be considered as markers of plant response to RIM. Non-target analysis enables to recognize the type of herbicide used during cultivation.


Subject(s)
Herbicides/toxicity , Pesticide Residues/analysis , Pyridines/toxicity , Raphanus/chemistry , Raphanus/drug effects , Sulfonamides/toxicity , Chromatography, Liquid , Cyclohexanones/pharmacokinetics , Cyclohexanones/toxicity , Environmental Biomarkers , Epinephrine/analysis , Mesylates/pharmacokinetics , Mesylates/toxicity , Metabolome , Normetanephrine/analysis , Plants, Edible/chemistry , Plants, Edible/drug effects , Pyridines/pharmacokinetics , Pyrimidines/toxicity , Raphanus/metabolism , Sulfonamides/pharmacokinetics , Tandem Mass Spectrometry , Tyramine/analysis
17.
Biomed Res Int ; 2020: 1649759, 2020.
Article in English | MEDLINE | ID: mdl-33381543

ABSTRACT

Passion for computer games negatively affects the health level of schoolchildren. Among the approaches to monitoring the functional state of such schoolchildren, the most informative and painless is the study of the saliva. The study involved 45 children, aged 14.00 ± 0.21 years, and divided according to the contact's intensity with computer games. The following indicators of lipid peroxidation (LPO) were determined in the saliva: indicators of the antioxidant (AO) system, concentration of immunoglobulin A, and hormonal indicators. The significant increases in the catecholamine (adrenaline) level for 2.3 times and biogenic amine-serotonin for 35.5% and increase in the LPO-DC product concentration in gamers for 75.8% were revealed. The study of the schoolchildren's homeostasis peculiarities confirmed the adequacy of the use of biochemical techniques to assess the condition of children gamers. They have a prenosological condition. This is reflected in the increase in LPO intensity, failure of the protective AO system, imbalance of hormonal state, and immunity deterioration. Information on the evaluation of the LPO activity processes and the AO system condition and the degree of the balance's shift between prooxidants and antioxidants in biological substrates can be considered objective and very sensitive indicators of the general condition, activity, and improvement of the regulation and maintenance of homeostasis.


Subject(s)
Adolescent/physiology , Saliva/chemistry , Video Games , Adolescent Health , Antioxidants/analysis , Epinephrine/analysis , Humans , Immunoglobulin A/analysis , Lipid Peroxidation/physiology , Male
18.
Int J Mol Sci ; 21(21)2020 Oct 27.
Article in English | MEDLINE | ID: mdl-33120955

ABSTRACT

Adrenaline, which participates in the neuroendocrine response that occurs during stress and perimenopause, may be tumorigenic. This exploratory study aimed at investigating whether non-tumorigenic and tumorigenic human breast epithelial cell lines are able to synthesize adrenaline. The study was carried out in non-tumorigenic (MCF-10A) and tumorigenic (MCF-7) human breast cell lines. Expression of enzymes involved in adrenaline synthesis was characterized by RT-qPCR, immunocytochemistry and western blot. Catecholamines and analogue compounds were quantified by HPLC-ECD. Functional assessment of the impact of drugs on cells' tumorigenic potential was assessed by determination of cell viability and clonogenic ability. Both MCF-10A and MCF-7 cells produce catecholamines, but the capacity to produce adrenaline is lower in MCF-10A cells. ß-adrenoceptor activation increases the capacity of MCF-10A cells to produce adrenaline and favor both cell viability and colony formation. It is concluded that exposure of human breast epithelial cells to ß-adrenoceptor agonists increases cell proliferation and the capacity to produce adrenaline, creating an autocrine potential to spread these adrenergic effects in a feed-forward loop. It is conceivable that these effects are related to tumorigenesis, bringing a new perspective to understand the claimed anticancer effects of propranolol and the increase in breast cancer incidence caused by stress or during perimenopause.


Subject(s)
Adrenergic Agonists/pharmacology , Breast Neoplasms/metabolism , Breast/cytology , Catecholamines/biosynthesis , Receptors, Adrenergic/metabolism , Breast/drug effects , Breast/metabolism , Breast Neoplasms/genetics , Catecholamines/analysis , Cell Line , Cell Proliferation/drug effects , Cell Survival/drug effects , Chromatography, High Pressure Liquid , Culture Media/analysis , Epinephrine/analysis , Epithelial Cells/cytology , Epithelial Cells/drug effects , Epithelial Cells/metabolism , Female , Gene Expression Regulation/drug effects , Humans , MCF-7 Cells , Norepinephrine/analysis , Propranolol/pharmacology
19.
Sci Rep ; 10(1): 14614, 2020 09 03.
Article in English | MEDLINE | ID: mdl-32884078

ABSTRACT

We employ chevron-like graphene nanoribbons (GNRs) synthesized by a solution-based chemical route to develop a novel electrochemical sensor for determination of the neurotransmitter epinephrine (EPI). The sensor surface, a glassy carbon electrode modified with GNRs, is characterized by atomic force microscopy, scanning electron microscopy and Raman spectroscopy, which show that the electrode surface modification comprises of bi-dimensional multilayer-stacked GNRs that retain their molecular structure. The charge transfer process occurring at the electrode interface is evaluated by electrochemical impedance spectroscopy. The sensor is applied to the determination of EPI, employing as an analytical signal the reduction peak corresponding to the epinephrinechrome-leucoepinephrinechrome transition (E = - 0.25 V) instead of the oxidation peak usually employed in the literature (E = + 0.6 V) in order to minimize interferences. The results obtained demonstrate that chevron-like nanoribbons synthesized by solution methods exhibit reliable electrocatalytic activity for EPI determination. Using differential pulse voltammetry, we obtain a linear concentration range from 6.4 × 10-6 to 1.0 × 10-4 M and a detection limit of 2.1 × 10-6 M. The applicability of the sensor was evaluated by determining EPI in pharmaceutical samples with satisfactory results.


Subject(s)
Electrochemical Techniques/methods , Epinephrine/analysis , Graphite/chemistry , Nanotubes, Carbon/chemistry , Spectrum Analysis/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...