Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.629
Filter
1.
BMC Cardiovasc Disord ; 24(1): 342, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970014

ABSTRACT

BACKGROUND: The trans femoral ipsilateral approach is often adopted for endovascular treatment (EVT) for better steerability of guidewires or better device deliverability. However, contrary to the trans femoral contralateral approach, ipsilateral antegrade puncture sometimes causes peculiar bleeding complications. CASE PRESENTATION: A 76-year-old female underwent EVT for chronic occlusion of the left superficial femoral artery (SFA) via the ipsilateral antegrade approach. After guidewire passage, we inflated the drug-coated balloons, but angiography showed blood flow stasis at the mid segment of the SFA. We also ensured prolonged balloon inflation, which resulted in favorable blood flow. While trying to ensure hemostasis, the blood pressure remained decreased, but neither bleeding nor superficial hematoma were observed at the puncture site. After hemostasis was achieved, we removed the surgical drape and noticed a swelling in the mid-portion of the thigh, distant from the puncture point. We then approached the left common femoral artery (CFA) contralaterally. Angiography showed continuous bleeding from a little bit distally to the sheath insertion point that was spreading through an intramuscular space. We stopped the bleeding with balloon tamponade inside the CFA. Angiography after hemostasis demonstrated blood flow stasis at the mid-segment of the SFA, similarly as that seen before. We confirmed compression of the SFA by a large hematoma using both intra- and extra- vascular ultrasound. Therefore, we deployed a self-expandable stent at the compressed SFA position. Finally, we achieved favorable blood flow on angiography. CONCLUSION: We encountered a case that latent bleeding unrecognized in the surgical field persisted while prolonged inflation of DCB was conducted at just proximal SFA. We could have avoided bailout stenting by noticing the bleeding incident in a timely manner. Prediction and prevention are essential for all kinds of procedural complications in EVT.


Subject(s)
Delayed Diagnosis , Femoral Artery , Hemorrhage , Punctures , Humans , Female , Aged , Femoral Artery/diagnostic imaging , Hemorrhage/etiology , Hemorrhage/therapy , Treatment Outcome , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Predictive Value of Tests , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects
2.
J Surg Res ; 299: 26-33, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38692185

ABSTRACT

INTRODUCTION: Whole blood (WB) has recently gained increased popularity as an adjunct to the resuscitation of hemorrhaging civilian trauma patients. We aimed to assess the nationwide outcomes of using WB as an adjunct to component therapy (CT) versus CT alone in resuscitating geriatric trauma patients. METHODS: We performed a 5-y (2017-2021) retrospective analysis of the Trauma Quality Improvement Program. We included geriatric (age, ≥65 y) trauma patients presenting with hemorrhagic shock (shock index >1) and requiring at least 4 units of packed red blood cells in 4 h. Patients with severe head injuries (head Abbreviated Injury Scale ≥3) and transferred patients were excluded. Patients were stratified into WB-CT versus CT only. Primary outcomes were 6-h, 24-h, and in-hospital mortality. Secondary outcomes were major complications. Multivariable regression analysis was performed, adjusting for potential confounding factors. RESULTS: A total of 1194 patients were identified, of which 141 (12%) received WB. The mean ± standard deviation age was 74 ± 7 y, 67.5% were male, and 83.4% had penetrating injuries. The median [interquartile range] Injury Severity Score was 19 [13-29], with no difference among study groups (P = 0.059). Overall, 6-h, 24-h, and in-hospital mortality were 16%, 23.1%, and 43.6%, respectively. On multivariable regression analysis, WB was independently associated with reduced 24-h (odds ratio, 0.62 [0.41-0.94]; P = 0.024), and in-hospital mortality (odds ratio, 0.60 [0.40-0.90]; P = 0.013), but not with major complications (odds ratio, 0.78 [0.53-1.15]; P = 0.207). CONCLUSIONS: Transfusion of WB as an adjunct to CT is associated with improved early and overall mortality in geriatric trauma patients presenting with severe hemorrhage. The findings from this study are clinically important, as this is an essential first step in prioritizing the selection of WB resuscitation for geriatric trauma patients presenting with hemorrhagic shock.


Subject(s)
Blood Transfusion , Hospital Mortality , Resuscitation , Shock, Hemorrhagic , Humans , Female , Male , Aged , Retrospective Studies , Resuscitation/methods , Resuscitation/statistics & numerical data , Aged, 80 and over , Shock, Hemorrhagic/therapy , Shock, Hemorrhagic/mortality , Shock, Hemorrhagic/etiology , Shock, Hemorrhagic/diagnosis , Blood Transfusion/statistics & numerical data , Blood Transfusion/methods , Wounds and Injuries/complications , Wounds and Injuries/mortality , Wounds and Injuries/therapy , Wounds and Injuries/diagnosis , Injury Severity Score , Hemostatic Techniques , Treatment Outcome
3.
Circ Cardiovasc Interv ; 17(6): e013842, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38708595

ABSTRACT

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.


Subject(s)
Endovascular Procedures , Hemostatic Techniques , Suture Techniques , Vascular Closure Devices , Humans , Prospective Studies , Male , Female , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Treatment Outcome , Time Factors , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Aged, 80 and over , Equipment Design , Punctures , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Hemorrhage/prevention & control , Hemorrhage/etiology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging
4.
Am Surg ; 90(6): 1540-1544, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38562123

ABSTRACT

BACKGROUND: Traumatic hemorrhage is a prevalent cause of death nationally, with >50% of civilian deaths estimated to be preventable with more timely intervention. This study investigated the efficacy of training large and diverse audiences in bleeding control methods including tourniquets in community health fair settings. METHODS: A booth was utilized for bleeding control training at community health fairs via direct demonstrations of pressure, wound packing, and commercial and improvised tourniquet application followed by hands-on practice. Participants self-rated their perceived abilities while instructors rated the participant competency. RESULTS: 117 community members participated during two fairs, though not every person completed every portion of the training. Average age was 33 (range 6-82) and the majority were female (65.0%). There was no difference in self-perceived skill compared to trainer grading of participant's ability to identify life-threatening bleeding (112 (97.4%) vs 106 (97.2%); P = 1), apply pressure (113 (98.3%) vs 106 (97.2%); P = .68), and pack a wound (102 (88.7%) vs 92 (84.4%); P = .43). No difference in difficulty was noted in placing commercial vs improvised tourniquets (16 (43%) vs 14 (45%); P = .87). However, participants were overconfident in their ability to place tourniquets compared to trainer grading, respectively (112 (98.2%) vs 100 (91.7%; P = .03)). DISCUSSION: Community fair classes provide opportunities to train large and diverse audiences in bleeding control techniques. However, participants overestimated their ability to appropriately apply tourniquets. Further investigation is needed into best educational approaches to optimize the impact of bleeding control kits that have been distributed in multiple states.


Subject(s)
Hemorrhage , Tourniquets , Humans , Female , Male , Adult , Hemorrhage/prevention & control , Hemorrhage/therapy , Middle Aged , Aged , Adolescent , Aged, 80 and over , Young Adult , Hemostatic Techniques
5.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639140

ABSTRACT

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Subject(s)
Catheterization, Peripheral , Femoral Artery , Hemostatic Techniques , Punctures , Suture Techniques , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Femoral Artery/diagnostic imaging , Male , Female , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Aged, 80 and over , Treatment Outcome , Catheterization, Peripheral/adverse effects , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Italy , Equipment Design , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Hemorrhage/etiology , Hemorrhage/prevention & control
6.
Ann Vasc Surg ; 105: 125-131, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38588952

ABSTRACT

BACKGROUND: Endovascular aortic surgery is increasingly becoming the standard treatment. Percutaneous access preclosing systems appear to be effective and notably the Proglide (PG). We aimed to prospectively assess the clinical effectiveness of combining ultrasound-guided femoral puncture with ultrasound-guided PG deployment. METHODS: Our single-center study consecutively included patients managed at a tertiary center from May to September 2023, undergoing endovascular aortic surgery. The placement of PG was performed under ultrasound guidance. Preoperative patient characteristics were evaluated using preoperative computed tomography scans. Clinical and technical success were defined, respectively, as the ability to achieve complete hemostasis confirmed by ultrasound 48 hr postprocedure and as the successful placement of a PG under ultrasound guidance contributing to final hemostasis. RESULTS: Twenty patients were included over a 6-month period, totaling 34 common femoral arteries (CFAs). Fourteen were male, with an average age of 72.8 ± 8.2 years. Among the 34 CFA, CFA had diameter of 12.05 ± 2.4 mm and a depth of 38.0 ± 13.4 mm. The mean introducer sheath diameter was 6.2 ± 1.5 mm with a sheath to femoral artery ratio of 0.54 ± 0.18. Successful Proglide placement under ultrasound guidance was achieved in 100% of cases. No PG failure occurred. Clinical and technical success were, respectively, of 95% and 100%. One small pseudoaneurysm was observed at 48 hr treated medically. No CFA access reintervention was required. CONCLUSIONS: The technique of ultrasound-guided PG deployment in aortic surgery is a safe and effective method for achieving hemostasis. It effectively prevents PG failures at a lower cost.


Subject(s)
Endovascular Procedures , Femoral Artery , Hemostatic Techniques , Punctures , Ultrasonography, Interventional , Humans , Male , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Aged , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Treatment Outcome , Prospective Studies , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Aged, 80 and over , Middle Aged , Catheterization, Peripheral/adverse effects , Vascular Closure Devices , Hemostatics/administration & dosage , Hemostatics/therapeutic use , Time Factors
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
9.
Vasc Endovascular Surg ; 58(6): 588-594, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38477544

ABSTRACT

OBJECTIVES: Manual compression (MC) or vascular closure devices (VCDs) are used to achieve hemostasis after percutaneous transluminal angioplasty (PTA). However, limited data on the comparative safety and effectiveness of VCDs vs MC in patients with end-stage renal disease (ESRD) undergoing PTA are available. Accordingly, this study compared the safety and effectiveness of VCD and MC in patients with ESRD undergoing PTA. METHODS: This single-center retrospective cohort study included the data of patients with ESRD undergoing peripheral intervention at Chang Gung Memorial Hospital, Taiwan, from January 1, 2019, to June 30, 2022. The patients were divided into VCD and MC groups. The primary endpoint was a composite of puncture site complications, including acute limb ischemia, marked hematoma, pseudoaneurysm, and puncture site bleeding requiring blood transfusion. RESULTS: We included 264 patients with ESRD undergoing PTA, of whom 60 received a VCD and 204 received MC. The incidence of puncture site complications was 3.3% in the VCD group and 4.4% in the MC group (hazard ratio: .75; 95% confidence interval: .16-3.56 L P = 1.000), indicating no significant between-group difference. CONCLUSION: VCDs and MC had comparable safety and effectiveness for hemostasis in patients with ESRD undergoing peripheral intervention.


Subject(s)
Hemostatic Techniques , Kidney Failure, Chronic , Peripheral Arterial Disease , Punctures , Vascular Closure Devices , Humans , Male , Female , Retrospective Studies , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Kidney Failure, Chronic/therapy , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/complications , Middle Aged , Treatment Outcome , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/diagnostic imaging , Taiwan , Risk Factors , Time Factors , Pressure , Hemorrhage/etiology , Aged, 80 and over , Risk Assessment
11.
Curr Opin Crit Care ; 30(3): 202-208, 2024 06 01.
Article in English | MEDLINE | ID: mdl-38441108

ABSTRACT

PURPOSE OF REVIEW: Noncompressible torso hemorrhage (NCTH) is now considered as the major cause of preventable death after both severe military and civilian trauma. Around 20% of all trauma patients still die from uncontrolled exsanguination along with rapidly evolving hemostatic failure. This review highlights the most recent advances in the field and provides an outline for future research directions. RECENT FINDINGS: The updated definition of NCTH includes a combination of high-grade anatomical torso injury, hemodynamic instability, urgent need for hemorrhage control and aggressive hemostatic resuscitation. Therapeutic concepts consider the following three aspects: control the bleeding source (close the tap), resuscitate to maintain organ perfusion and restore hemostasis (fill the tank), and increase the body's resistance against ischemia (upgrade the armor). SUMMARY: The concepts for the early management of NCTH have substantially evolved over the last decade. The development of new devices and techniques combined with early intervention of hemostatic failure have contributed to more successful resuscitations. Future research needs to refine and validate their potential clinical application.


Subject(s)
Hemorrhage , Resuscitation , Humans , Resuscitation/methods , Hemorrhage/therapy , Torso , Hemostatic Techniques , Exsanguination/therapy
12.
J Invasive Cardiol ; 36(5)2024 May.
Article in English | MEDLINE | ID: mdl-38422529

ABSTRACT

OBJECTIVES: Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. METHODS: We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. RESULTS: PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P less than .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P less than .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. CONCLUSIONS: The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.


Subject(s)
Percutaneous Coronary Intervention , Radial Artery , Humans , Male , Female , Aged , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Middle Aged , Arterial Occlusive Diseases/prevention & control , Arterial Occlusive Diseases/etiology , Arterial Occlusive Diseases/diagnosis , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Incidence , Hemostasis/physiology , Italy/epidemiology , Treatment Outcome , Equipment Design
13.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article in English | MEDLINE | ID: mdl-38184452

ABSTRACT

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Subject(s)
Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Hemostatic Techniques , Punctures , Vascular Closure Devices , Humans , Retrospective Studies , Male , Female , Treatment Outcome , Middle Aged , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Time Factors , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Device Removal/adverse effects , Suture Techniques/instrumentation , Suture Techniques/adverse effects , Femoral Artery , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnosis , Risk Factors , Hemorrhage/etiology , Hemorrhage/prevention & control
14.
J Vasc Surg ; 79(4): 740-747.e2, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38056701

ABSTRACT

BACKGROUND: Percutaneous access and use of vascular closure devices facilitate thoracic endovascular aortic repair (TEVAR) procedures during local anesthesia and allow immediate detection of signs of spinal ischemia. However, the very large bore access (usually ≥22F sheath) associated with TEVAR increases the risk of vascular complications. In this study, we sought to define the safety and feasibility of two percutaneous femoral artery closure devices during TEVAR, in terms of access site vascular complications and major, life-threatening, or fatal bleeding (≥major) within 48 hours. Access site vascular complications were defined as technical failure of vascular closure or later formation of pseudoaneurysm. METHODS: From March 2010 to December 2022, 199 transfemoral TEVAR were performed at Helsinki University Central Hospital, Finland. We retrospectively categorized these into three groups, based on surgeon preference for the access technique and femoral artery closure method: (1) surgical cut-down and vessel closure, n = 85 (42.7%), (2) percutaneous access and vascular closure with suture-based ProGlide, n = 56 (28.1%), or (3) percutaneous access and vascular closure with ultrasound-guided plug-based MANTA, n = 58 (29.1%). The primary outcome measure was technical success of vascular closure and access site vascular complications during index hospitalization. Secondary outcome measures were ≥major bleeding, early mortality, and hospital stay. RESULTS: The technical success rate was 97.6% vs 91.1% vs 93.1% for surgical cut-down, ProGlide, and MANTA, respectively (P = .213). The rate of access site vascular complication was 3.5% vs 8.9% vs 10.3%, respectively (P = .290), with two pseudoaneurysms detected postoperatively and conservatively managed in the MANTA group. The vascular closure method was not associated with increased risk of ≥major bleeding, early mortality, or hospital stay on univariate analysis. Predictors for ≥major bleeding after TEVAR in multivariable analysis were urgent procedure (odds ratio: 2.8, 95% confidence interval: 1.4-5.5; P = .003) and simultaneous aortic branch revascularization (odds ratio: 2.7, 95% confidence interval: 1.3-5.4; P = .008). CONCLUSIONS: In this study, the technical success rates of the percutaneous techniques demonstrated their feasibility during TEVAR. However, the number of access site complications for percutaneous techniques was higher compared with open approach, although the difference was not statistically significant. In the lack of evidence, the safety of the new MANTA plug-based vascular closure for TEVAR warrants further investigation.


Subject(s)
Catheterization, Peripheral , Endovascular Procedures , Vascular Closure Devices , Humans , Endovascular Aneurysm Repair , Retrospective Studies , Treatment Outcome , Hemorrhage/etiology , Hemorrhage/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects
15.
Am Surg ; 90(3): 455-464, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37970830

ABSTRACT

BACKGROUND: Hemodynamically unstable pelvic fractures are often life-threatening injuries; however, the optimal management remains uncertain. This systematic review and meta-analysis aim to evaluate the most appropriate primary management of hemorrhage in adult patients with hemodynamically unstable pelvic fractures by comparing outcomes following the initial use of preperitoneal packing (PPP) vs angioembolization (AE). METHODS: A systematic search of PubMed, Embase, Google Scholar, and ProQuest databases was conducted following PRISMA guidelines. Studies assessing hemorrhage management in trauma patients with hemodynamically unstable pelvic fractures were included. The data extracted from selected articles included patient demographics, study design, and outcomes such as 24-hour PRBC transfusions, in-hospital mortality, and DVT rate. RESULTS: Eight articles were included in the systematic review. Among the included studies, 2040 patients with hemodynamically unstable pelvic fractures were analyzed. Meta-analyses revealed that treatment with PPP was associated with fewer 24-hour PRBC transfusions (mean difference = -1.0, 95% CI: -1.8 to -.2) than AE. However, no significant differences were noted in in-hospital mortality (RR: .91, 95% CI: .80-1.05) and the rate of deep vein thrombosis (RR: .89, 95% CI: .62-1.28) between groups. CONCLUSION: The findings of this study suggest that primary management with PPP was associated with fewer 24-hour PRBC transfusions compared to AE. The choice of primary management with PPP or AE did not significantly impact in-hospital mortality. Future studies should address clinical outcomes and the factors that affect them to better understand the impact of different management strategies and direct the creation of practice management guidelines.


Subject(s)
Fractures, Bone , Pelvic Bones , Adult , Humans , Fracture Fixation , Fractures, Bone/complications , Fractures, Bone/therapy , Hemorrhage/therapy , Hemorrhage/complications , Pelvic Bones/injuries , Hemostatic Techniques , Retrospective Studies
16.
J Trauma Acute Care Surg ; 96(2): 256-264, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37858305

ABSTRACT

BACKGROUND: Hemorrhage control in prolonged field care (PFC) presents unique challenges that drive the need for enhanced point of injury treatment capabilities to maintain patient stability beyond the Golden Hour. To address this, two hemostatic agents, Combat Gauze (CG) and XSTAT, were evaluated in a porcine model of uncontrolled junctional hemorrhage for speed of deployment and hemostatic efficacy over 72 hours. METHODS: The left subclavian artery and subscapular vein were isolated in anesthetized male Yorkshire swine (70-85 kg) and injured via 50% transection, followed by 30 seconds of hemorrhage. Combat Gauze (n = 6) or XSTAT (n = 6) was administered until bleeding stopped and remained within subjects for observation over 72 hours. Physiologic monitoring, hemostatic efficacy, and hematological parameters were measured throughout the protocol. Gross necropsy and histology were performed following humane euthanasia. RESULTS: Both CG and XSTAT maintained hemostasis throughout the full duration of the protocol. There were no significant differences between groups in hemorrhage volume (CG: 1021.0 ± 183.7 mL vs. XSTAT: 968.2 ± 243.3 mL), total blood loss (CG: 20.8 ± 2.7% vs. XSTAT: 20.1 ± 5.1%), or devices used (CG: 3.8 ± 1.2 vs. XSTAT: 5.3 ± 1.4). XSTAT absorbed significantly more blood than CG (CG: 199.5 ± 50.3 mL vs. XSTAT: 327.6 ± 71.4 mL) and was significantly faster to administer (CG: 3.4 ± 1.6 minutes vs. XSTAT: 1.4 ± 0.5 minutes). There were no significant changes in activated clot time, prothrombin time, or international normalized ratio between groups or compared with baseline throughout the 72-hour protocol. Histopathology revealed no evidence of microthromboemboli or disseminated coagulopathies across evaluated tissues in either group. CONCLUSION: Combat Gauze and XSTAT demonstrated equivalent hemostatic ability through 72 hours, with no overt evidence of coagulopathies from prolonged indwelling. In addition, XSTAT offered significantly faster administration and the ability to absorb more blood. Taken together, XSTAT offers logistical and efficiency advantages over CG for immediate control of junctional noncompressible hemorrhage, particularly in a tactical environment. In addition, extension of indicated timelines to 72 hours allows translation to PFC.


Subject(s)
Hemostatics , Swine , Male , Humans , Animals , Hemostatics/therapeutic use , Disease Models, Animal , Hemorrhage/therapy , Exsanguination/therapy , Hemostasis , Hemostatic Techniques
17.
J Vasc Surg ; 79(3): 569-576, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37923021

ABSTRACT

OBJECTIVE: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR). METHODS: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up. RESULTS: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m2. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events. CONCLUSIONS: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.


Subject(s)
Aortic Aneurysm , Endovascular Procedures , Vascular Closure Devices , Humans , Aged , Aged, 80 and over , Endovascular Procedures/adverse effects , Hemostatic Techniques , Retrospective Studies , Treatment Outcome , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
18.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-37982158

ABSTRACT

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Femoral Artery/surgery , Hemorrhage/etiology , Hemorrhage/prevention & control , Hemostatic Techniques/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Vascular Closure Devices/adverse effects
19.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Article in English | MEDLINE | ID: mdl-38059295

ABSTRACT

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Subject(s)
Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Catheterization, Peripheral/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemostatic Techniques/adverse effects
20.
J Vet Cardiol ; 51: 124-137, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38128418

ABSTRACT

INTRODUCTION/OBJECTIVES: Manual compression has been standard of care for maintaining hemostasis after percutaneous endovascular intervention, but can be time-consuming and associated with vascular complications. Alternative closure methods include the figure-of-eight suture (Z-stitch) and vascular closure device (VCD) techniques. We hypothesized that compared to manual compression, Z-stitch and VCD would significantly reduce time-to-hemostasis after transvenous access, and the proportion of dogs with vascular patency would not differ significantly among treatments. ANIMALS: Forty-six client-owned dogs undergoing percutaneous transvenous interventional procedures. MATERIALS AND METHODS: Dogs with vessel diameter <5 mm were randomized to undergo manual compression or Z-stitch, while those with vessel diameter ≥5 mm were randomized to undergo manual compression, Z-stitch, or VCD. Time-to-hemostasis, bleeding scores, presence of vascular patency one day and two to three months post-procedure, and complications were recorded. Data are presented as median (95% confidence interval). RESULTS: In all 46 dogs, the right external jugular vein was used. Time-to-hemostasis was significantly shorter in the Z-stitch (2.1 [1.8-2.9] minutes) compared to VCD (8.6 [6.1-11.8] minutes; P<0.001) and manual compression (10.0 [10.0-20.0] minutes; P<0.001) groups. Time-to-hemostasis was significantly shorter in the VCD vs. manual compression (P=0.027) group. Bleeding scores were significantly greater at 5 and 10 min (P<0.001 and 0.013, respectively) in manual compression, compared to Z-stitch group. There was no difference in the proportion of dogs with vascular patency between groups (P=0.59). CONCLUSIONS: Z-stitch and VCD are effective venous hemostasis methods after percutaneous transvenous intervention, with Z-stitch providing the most rapid time-to-hemostasis. Both Z-stitch and VCD techniques have low complication rates and effectively maintain vascular patency.


Subject(s)
Dog Diseases , Hemostatic Techniques , Postoperative Hemorrhage , Vascular Closure Devices , Vascular Surgical Procedures , Animals , Dogs , Dog Diseases/surgery , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Hemostatic Techniques/veterinary , Treatment Outcome , Vascular Closure Devices/veterinary , Vascular Closure Devices/adverse effects , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/methods , Postoperative Hemorrhage/prevention & control , Postoperative Hemorrhage/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...